Loading...
HomeMy WebLinkAboutB08-0085 withdrawnOFFICE USE Date Received: Received By: http://www.vailgov.com/ docs/di.jorms/building—permitL4-17-2007. DOC �:E ��r %: ��:^F;��6-• .;.'""- . r!z.?'�".NY.. ti's:= �'•,�`v' ¢ sS_1 s t -„r•- sr•�., "".n�"• MSY: i�'2 . rs,'��• . ,,� �.'s' ;.•r� .., -.�`. ,,.. W. N ,; ,: r•..,..y.:r xYC: K`w. •% .rrxc' �e7::. rr a ,S nid s.. Y '�,�^%�'. r. � }y4.. nk� �� i'iY•.''r �,:' �.'.�'%e ' . :'. - �.4' ;;�� :.rx'�� � w�, ;� •tat; ^� � ,'as`;:�,% - r-- '..o... ��"� � ,� "�^ 'mow °k:• . ���•�. �s'e :%� �, ., .. - i: f F �f�:��Y.'. - d•�6o;6� &' k'�•".•,i_..w � �.c.v'wr'�.._. �"s: ��k$ •� �' i 1:�i1�f ��YrTy`;J fi I4:�ul.yt M BUILD""'ING"' PER"M APPLICATION CHECKLI COMMERCIAL TENANT FI This checklist is to be used with any tenant finish /improvement permit application. -R-- Town of Vail Design Review Board approval must first be obtained for any exterior modifications proposed -�R- Plan Check Fee must be paid at the time of application for projects over $100,000 valuation (see attached schedule) The following information must be shown on all 4 sets of plans: Pr Construction plans stamped and signed by a Colorado State Licensed Architect. [?r original building construction type per IBC chapter 6 ex. II -A, V_B R-7` Tenant suite or tenant space number. r CK Tenant space location identification. Show location of the tenant space within the overall building. Floor plans with existing and proposed walls. Show all wall assembly construction and proposed interior finishes with flamespread index. Proposed construction type must match existing building construction type. Clearly show proposed use of each room or space on the plans. 2 Reflected ceiling and finish plan. Type of materials must match the fire resistance /type of construction requirements in the existing building. Show all interior ceiling finishes and flamespread index F Door schedule. All doors shall be clearly identified with fire rating, size, hardware and swing. F-o' Means of egress plan. Show all occupant loads and number of exits from the tenant space ❑ Areas requiring two (2) exits: Exit doors shown to swing in the direction of exit travel, separation of exits comply with code, illuminated exit signs are shown. Windows shall be labeled with size, operation, safety glass. 5' All areas and rooms of the tenant space are accessible per ANSI 117.1 requirements. 13' Accessible maneuvering clearances provided at all doors for accessibility per ANSI 1 17,1 E;K' Service countertops and built -in work stations provided with accessible areas per ANSI 117.1 G' Bathroom facilities. All accessibleladaptable features, clearances and turning spaces provided per ANSI 117.1 requirements must be shown. -f4- separate sex bathroom facilities provided if the number of occupants or employees exceeds (15). 2r Toilet room floors /walls finish schedule. ❑ Floors have a smooth, hard, nonabsorbent surface such as concrete, ceramic the or other approved material, extending upward onto the walls at least 5 ". ❑ Walls within 2 feet of the front and sides of urinals and water closets must have a smooth, hard nonabsorbent surface to a height of 4 feet. K occupancy separations for walls /ceilings between tenants clearly shown on the plans with fire resistive construction details and listings specified. F"' Fire - stopping. Fire - stopping penetration details for plumbing, mechanical and electrical components in all fire rated walls and ceilings. [_< Plumbing, Electrical and Mechanical P lans stamped b a Colorado State Licensed E n g ineer y g Mechanical HVAC plans, plumbing plans, electrical plans /panel schaduleslload calculations. Fire /smoke Dampers on mechanical plans at all duct penetrations into fire resistive walls and ceilings. Fire sprinkler plans. Show all proposed work per Vail Fire and Emergency Services requirements Fire alarm plans. Show all proposed work per Vail Fire and Emergency Services requirements I have read and understand the . requirements of this checklist If an r Information is missing from the q y q g i application, I understand the application will not be accepted. Applicant's Signature Date 5' 2-�g http* DOC Page 3 of 7 04/17/2007 . ....... ........ ... .. .. .. . ............ J P ......................................... THE TOWN OF VAIL AND STATE O COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED"TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1068 THAT HAVE NO ASBESTOS CONTAINING ,MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION o I have included the asbestos test and report with m buildin permit application applicant si date e I certif m pro will not disturb or remove more than 160 s.f. of buildin material. The construction plans submitted with m application clearl indicate .this information. ( This will be verified durin plan review, and will dela y our pro if found to be inaccurate applicant si ............. date OR The buildin was constructed after October 12, 1988. The date of construction was 14IFNAf CZ>%!:� In si app Zln si date ori construction date http://www.vailgov.com/docs/di—forms/buildin 4-17-2007.DOC Pa 5 of 7 04/17/2007 WHEN A "PUBLIC WAY PERMIT" IS REQUIRED PLEASE READ AND CHECK OFF EACH OF THE FOLLOWING QUESTIONS REGARDING THE NEED FOR A "PUBLIC WAY PERMIT": o Is this a new residence? YES NO ✓ ❑ Does demolition work bein performed re the use 9 f the Ri easements or public propert YES NO o Is an utilit work needed? YES NO ❑ Are there an improvements bein done to the drivewa YES NO o Is a different access needed to the site other than the existin drivewa YES. NO o Is an draina work bein done hat hat affects the Ri easements, or public propert YES NO . ❑ Is a "Revocable Ri Permit' re YES NO o Is the Ri easement r public propert to be used for sta parkin or fencin YES NO If answer it NO, is a parkin 7 t g in g or fencin plan re b Public Works? YES NO If y ou have answered YES to an of these q uestions, a "Public Wa Permit" must be obtained. "Public Wa Permit" applications ma be obtained at the Public Works office or at Communit Development. If y ou have an q uestions please call Leonard Sandoval in Public Works at 970-479-2198. I HAVE READ AND ANSWERED ALL THE ABOVE QUESTIONS. r-wc-f, P-EST bowV1 00 Contractor g haMure Compan Name Job or Project Name: iTZ • C4M�Xxbt.-A r tftP, A AgP_xz)T- T roi Date Si ti zC�z>ly http://www.valigov.com/docs/dl-forms/buildin -4-17-2007. DOC Pa 6 of 7 04/17/2007 TOWN OF ''WAIL, COLORADO Statement Statement Number: R❑8❑❑01246 Amount: $627.74 ❑7/24/2❑ ❑8❑2:45 PM Pa Method: Check Inlit: JLE Notation,. 2747 ALLIANCE ----------------------------------------------------------------------------- Permit No: B❑8-❑ ❑85 T ADD/ALT COMM BUILD PERMT Parcel No: 21❑1-❑72-17❑❑ -1 Site Address: 720 W LIONS HEAD CR VAIL Location: MARRIOTT, 6TH FLOOR, WEST WING Total Fees: $92,487.13 This Pa $627.74 Total ALL Pmts: $627.74 Balance: $91,859.39 ACCOUNT ITEM LIST: Account-Code Description Current Pmts -------------------- ------------------------ ------------ ..PF PLAN CHECK FEES 627.74