Loading...
HomeMy WebLinkAboutF05-0071 plans modifications June 16, 2010PROJECT DIRECTORY OWNER CONTRACTOR FERRUCO VAIL VENTURES FERRUCO VAIL VENTURES 16 VAIL ROAD 16 VAIL ROAD VAIL, CO 81657 VAIL, CO 81657 T 970- 963 -4626 T 970- 477 -8034 CONTACT: GREG SPENCER CONTACT: MARK NORRIS ARCHITECT STRUCTURAL ENGINEER MONROE & NEWELL TIMBERS RESORTS P.O. BOX 1597 201 MAIN STREET, SUITE 202 70 BENCHMARK ROAD, SUITE 204 CARBONDALE, CO 81623 AVON, CO 81620 T 970 - 963 -4626 T 970 - 949 -7768 F 970 - 963 -4616 F 970 - 949 -4054 CONTACT: MARK RUDOLF CONTACT: HANNES SPAEH of"ll Min g] [a:] 1:4 a PROJECT INFORMATION PROJECT DESCRIPTION THE SCOPE OF THIS PROJECT INCLUDES THE CONSTRUCTION OF DECORATIVE SOFFITS TO HIDE SPRINKLER LINES AND HEADS AND TO PROVIDE THE NECESSARY HEAT SHELF. THESE MODIFICATIONS ARE BEING MADE TO COMPLY WITH CODE REQUIREMENTS FOR ATRIUM SPACES. PHYSICAL ADDRESS: 16 VAIL ROAD VAIL, CO 81657 CODE & ZONING INFORMATION: OCCUPANCY: S -2 STORAGE (PARKING)B F -1 MODERATE HAZARD INDUSTRIAL A -2 ASSEMBLY (FOOD & BEVERAGE) B BUSINESS R -1 RESIDENTIAL (HOTELS) R -2 RESIDENTIAL (TIME SHARE) TYPE OF CONSTRUCTION: t -A ALLOWABLE AREA: UNLIMITED TOTAL EXISTING BUILDING AREA: 319,467 S.F. ADDITIONAL AREA: 0 S.F. TOTAL PRPOSED AREA: 319,467 S.F. SPRINKLERED: YES BUILDING CODE USED: 2009 IBC ACCESSIBILITY CODE ANSI 117.1 -2003 ARCHITECTURAL SYMBOLS j� C BUILDING SECTION OR ELEVATION A Ag REFERENCE DRAWING NUMBER COLUMN GRID r DETAIL DESIGNATION C 5' REFERENCE DRAWING NUMBER clil REVISION 3 REFERENCE PROJECT A5.3 INTERIOR ELEVATION NORTH ARROW REFERENCE DRAWING NUMBER 1 FLOOR LEVEL LEVEL LINE EL: 100' -0" DASH AND DOT LINE FOR CENTER LINES, FLOOR LINES - _ IN EXTERIOR ELEVATIONS, PROJECTED LINES WINDOW DASH AND DOUBLE DOT LINE FOR PROPERTY LINES, TYPE BOUNDARY LINES PLAN NOTE DASHED LINE FOR HIDDEN LINES 4 REFERENCE - (ABOVE OR BELOW) DOOR NUMBER BREAK LINE TO BREAK OFF ( �) (IF MORE THAN ONE DOOR PER ROOM PARTS OF DRAWINGS SUB LETTERS ARE USED) 11" 7" W JI Z W CA Z (j) Z Z Q i 2 u- to I w g a o w 5 0i INTERIOR OF RESTAURANT 6 1 0`801 ALIGN BTM. OF SHELF 2 I I WITH BTM. OF EXISTING BULLNOSE TRIM WOOD TRIM TO MATCH ADJACENT CASING /I 1 io \ R SPRINKLER HEAD MTIL. FRAMING RESTAURANT SOFFIT DETAIL NEW AWNING BY OTHERS I M7 2 -1/2" STL. STUDS @16" O.C. REMOVE UPPER WINDOW & REPLACE W/ 8 "GWB ON 3 -5/8" STL. STUDS @ 16" O.C. 5 " GWB ON 3 -1/2" STL. STUDS @16" O.G. -- NEW WINDOW WASH SPRINKLER HEADS - VERIFY REQ'D DISTANCE FROM WINDOW AND HEAD TYPE - BOTTOM WINDOW TO REMAIN 1 , -6 " BARIRESTAU RANT I A A a III 1 01 El I J