HomeMy WebLinkAboutF05-0071 plans modifications June 16, 2010PROJECT DIRECTORY
OWNER
CONTRACTOR
FERRUCO VAIL VENTURES
FERRUCO VAIL VENTURES
16 VAIL ROAD
16 VAIL ROAD
VAIL, CO 81657
VAIL, CO 81657
T 970- 963 -4626
T 970- 477 -8034
CONTACT: GREG SPENCER
CONTACT: MARK NORRIS
ARCHITECT
STRUCTURAL ENGINEER
MONROE & NEWELL
TIMBERS RESORTS
P.O. BOX 1597
201 MAIN STREET, SUITE 202
70 BENCHMARK ROAD, SUITE 204
CARBONDALE, CO 81623
AVON, CO 81620
T 970 - 963 -4626
T 970 - 949 -7768
F 970 - 963 -4616
F 970 - 949 -4054
CONTACT: MARK RUDOLF
CONTACT: HANNES SPAEH
of"ll
Min g] [a:] 1:4 a
PROJECT INFORMATION
PROJECT DESCRIPTION
THE SCOPE OF THIS PROJECT INCLUDES THE
CONSTRUCTION OF DECORATIVE SOFFITS TO HIDE
SPRINKLER LINES AND HEADS AND TO PROVIDE THE
NECESSARY HEAT SHELF. THESE MODIFICATIONS ARE
BEING MADE TO COMPLY WITH CODE REQUIREMENTS FOR
ATRIUM SPACES.
PHYSICAL ADDRESS:
16 VAIL ROAD
VAIL, CO 81657
CODE & ZONING INFORMATION:
OCCUPANCY: S -2 STORAGE (PARKING)B
F -1 MODERATE HAZARD INDUSTRIAL
A -2 ASSEMBLY (FOOD & BEVERAGE)
B BUSINESS
R -1 RESIDENTIAL (HOTELS)
R -2 RESIDENTIAL (TIME SHARE)
TYPE OF CONSTRUCTION: t -A
ALLOWABLE AREA: UNLIMITED
TOTAL EXISTING BUILDING AREA: 319,467 S.F.
ADDITIONAL AREA: 0 S.F.
TOTAL PRPOSED AREA: 319,467 S.F.
SPRINKLERED: YES
BUILDING CODE USED: 2009 IBC
ACCESSIBILITY CODE ANSI 117.1 -2003
ARCHITECTURAL SYMBOLS
j�
C BUILDING SECTION OR ELEVATION
A Ag REFERENCE DRAWING NUMBER
COLUMN GRID r DETAIL
DESIGNATION C 5' REFERENCE DRAWING NUMBER clil
REVISION
3 REFERENCE
PROJECT A5.3 INTERIOR ELEVATION
NORTH ARROW REFERENCE DRAWING NUMBER
1
FLOOR LEVEL LEVEL LINE
EL: 100' -0" DASH AND DOT LINE FOR CENTER LINES, FLOOR LINES
- _ IN EXTERIOR ELEVATIONS,
PROJECTED LINES
WINDOW DASH AND DOUBLE DOT LINE FOR PROPERTY LINES,
TYPE BOUNDARY LINES
PLAN NOTE DASHED LINE FOR HIDDEN LINES
4 REFERENCE - (ABOVE OR BELOW)
DOOR NUMBER BREAK LINE TO BREAK OFF
( �) (IF MORE THAN ONE DOOR PER ROOM PARTS OF DRAWINGS
SUB LETTERS ARE USED)
11" 7"
W JI
Z W
CA Z (j) Z
Z Q i 2
u- to I w g
a o w
5 0i INTERIOR OF
RESTAURANT
6 1
0`801 ALIGN BTM. OF SHELF 2 I I
WITH BTM. OF EXISTING
BULLNOSE TRIM
WOOD TRIM TO MATCH
ADJACENT CASING
/I 1
io \ R
SPRINKLER HEAD
MTIL. FRAMING
RESTAURANT SOFFIT DETAIL
NEW AWNING BY
OTHERS
I
M7
2 -1/2" STL. STUDS @16" O.C.
REMOVE UPPER WINDOW &
REPLACE W/ 8 "GWB ON
3 -5/8" STL. STUDS @ 16" O.C.
5 " GWB ON 3 -1/2" STL.
STUDS @16" O.G. --
NEW WINDOW WASH
SPRINKLER HEADS - VERIFY
REQ'D DISTANCE FROM
WINDOW AND HEAD TYPE -
BOTTOM WINDOW TO REMAIN
1 , -6 "
BARIRESTAU RANT
I A
A a III
1
01 El
I
J