Loading...
HomeMy WebLinkAboutF10-0067 1 TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F10-0067 Job Address: 720 W LIONSHEAD CR VAIL Status ...: ISSUED Location • Applied ..: 09/10/2010 Parcel No...: 210107217001 Issued . .: 10/06/2010 Project No : Expires. .: OWNER DIAMONDROCK VAIL OWNER LLC 09/10/2010 C/O DIAMONDROCK HOSPITALITY CO 6903 ROCKLEDGE DR STE 800 BETHESDA ( MD 20817 APPLICANT WESTERN STATES FIRE PROTECTI 09/10/2010 Phone: 303 - 792 -0022 7026 S TUCSON WAY ENGLEWOOD CO 80112 License: 338 -S CONTRACTOR WESTERN STATES FIRE PROTECTI 09/10/2010 Phone: 303 - 792 -0022 7026 S TUCSON WAY ENGLEWOOD CO 80112 License: 338 -S Desciption: RELOCATE (17), PLUG (5) EXISTING SPRINKLER HEADS DUE TO RESTAURANT REMODEL. WILL CHANGE ALL HEADS TO CONCEALERS. Valuation: $6,235.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ***************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ** Mechanical - -> $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees - - -> $696.99 Plan Check - -> $432.00 DRS Fee- > $0.00 Additional Fees > $0.00 Investigation -> $0.00 TOTAL FEES > $696.99 Total Permit Fee >' $696.99 WilI CaII > $0.00 Payments > $696.99 BALANCE DUE > $0.00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 09/14/2010 mvaughan Action: AP • CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all } Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SIGNA RE OF"O R OR CONTRACTOR FOR HIMSELF O O MSE AND OWNER I } �11 t €gg gg r _ g , , 1 : [ , t, , [ , - , , I TOWN OF VAIL, COLORADO Statement ******************************************************************************************** Statement Number: R100001481 Amount: $696.99 10/06/201009:02 AM I Payment Method: Check Init: SAB 1 Notation: 120510 W.S.F.P i Permit No: F10-0067 Type: SPRINKLER PERMIT 1 Parcel No: 2101-072-1700-1 Site Address: 720 W LIONSHEAD CR VAIL i Location: ; Total Fees: $696.99 I 1 This Payment: $696.99 Total ALL Pmts: $696.99 i I Balance: $0.00 1, i ACCOUNT ITEM LIST: i Account Code Description Current Pmts 1 BP 00100003111100 SPRINKLER PERMIT FEES 264.99 I PF 00100003112300 PLAN CHECK FEES 432.00 1 i i 1 i t i i i , ; f : ' i , , ; • I I • 1 1 t i i i 1 I , 1 .• ., t , , I , • 1 , i , • ! ! , ! i E t 1 c I ! , [ ' , , 1 i g, Department.of Community Development. •;"�, -�� r 75 South Frontage Road ►': w 1 . , , _ " .x q Vail, Colorado. 81657 Fait'-'.976 b ' S. - Va11�0 �e r FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor P roject Street Address: 1 - 71 5 W• Lro n 3 l ica. d r✓, Q.c I L (Number) (Street) (Suite #) Building /Complex Name: 1fA=tL jM/�QiQio - - -_ OFF. 3 easoo5 ,__s-g -- - Contractor Information: p ( Company: L0641> i 5��.{s�F��_ I kD"CVA !Company Address: So Y1. W+A J 11 city — ekt�ktm t State: t0 Zip: Office Use: Project #: P�r� �D -1) (o Building Permit #: r a c / H Sprinkler Permit #: V j coca / Lot #: Block # Subdivision: Detailed Description of Work: kjocjZ )Z �I�5 > O)Cest.rtA 5RK;VlLJfA_ eud 5 Due- AD Contact Name: P kA AVrizV\ {ft, l 4o,,�dk J , 1vi11 ckauv, all heA� S f2 Collc (use additional sheet if necessary) Contact Phone: 3 � 3� 5 - 1 a - 57 9 7CL E -Mail woe,. h,agJen 6A 1 5 F9. U S Town of Vail Contractor Registration No.: 3 3 1 - s X Ile--( �7 1, , - Contra or Signatufe (req red) Property Information Detailed Location of Work: OFF $eq&v- �S cuQAKf Does a Monitored Fire Alarm Exist? Yes ()a No ( ) Does a Sprinkler System Exist? Yes No ( ) Work Class: Parcel #: a D - O7a2 - 1 - 7 -601 New ( ) Addition( ) Remodel Repair( ) (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Retro -Fit ( } Other ( ) /� ... _ ...,... Tenant Name: M.AfU A - D FF Sea 5 —t. (&s f J - $ Type of Building: Owner Name: q y11p ►1�. Rp L 1 Single- Family ( ) Duplex ( ) Multi - Family ( ) Commercial ( Restaurant ( ) Other ( ) Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler $: P � - 3 5- i Date Receive E V IE I D 4 (09b,g9 SEP o 9 1010 TOWN OF VAIL of -Feb-to Western States Fire Protection Co. ;v30&e'IM* Z�ued aKd �za� Material Submittal FOR Restaurant 715 W. Lionshead Circle Vail CO 81657 Tenant Finish Vail Marriott Off Season D [EC[EOMIE SEP 0 9 2010 D TOWN OF VAIL Prepared by: Jeff Hagan Project Manager Western States Fire Protection Co. 7026 S. Tucson Way Centennial, CO 80112 Phone (303) 792 -0022 Fax (303) 792 -9049 Cell (303 -549 -9553 Email jeff.hagan @wsfp.us WSFP #CS0963 August 26, 2010 MATERIAL INDEX Description Model I. Sprinkler Heads A. Quick Response Concealed Automatic Sprinkler II. Pipe — 1 -1/4" and smaller threaded A. Black Schedule 40 Pipe III. Pipe — 1 -1/2" and larger grooved A. Black Schedule 10 Pipe IV. Cast Iron Fittings V. Pipe Hangers (Per NFPA 13) A. Top Beam Clamps w/ Lock nut B. All Thread Rod C. Adjustable Ring Hanger D. Drop in Concrete Anchors G4A Manufacturer Reliable ASTM A 795 Varies" ASTM A 13 5 Varies" Varies Varies" Fig 68 Tolco Fig. 100 Tolco Fig. 200 Tolco HDI -P 3/8 Hilti "Because of the current escalation occurring with steel, WSFP reserves the right to substitute pipe as required to meet project schedules. R 1 0 inble Bulletin 154 Rev.E Model G4A Quick Response Concealed Automatic Sprinkler The Concealer UL Quick Response FM Standard Response Concealed Sprinkler With a %" (13mm) or 1 %" (38mm) Adjustment Features 1. Cover plate attachment with %" (13mm) assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in brass, chrome or black plated and white painted finishes. 5. Ordinary temperature rating. 6. Multiple orifices for design flexibility. Approvals & Listings 1. Underwriters Labortories, Inc. (ULY Quick Response 2. Underwriters Laboratories of Canada (ULC}- Quick Response 3. Factory Mutual Research Corp. (FMY Standard Response • Light Hazard Occupanicies- No Limitations • Ordinary Hazard Occupancies Groups 1 & 2 Wet Systems Only 4. NYC MEA 258 -93-E - Quick Response U.S. Patent number 4,880,063. Application The Reliable Model G4A Concealer is the most versatile quick response concealed sprin- kler available. It provides the best form of fire protection while offering an attractive appearance and 1 /2" (13mm) of cover adjust- ment for ease of installation. The small diameter cover plate as- sembly is easily attached and blends into the ceiling, concealing the most dependable fire protec- tion available, an automatic sprinkler system. The Model G4A ConcealerO is designed for use where aesthetic appearance is important. Offices, hospitals, motels and restaurants are but a few of the applications where it can be used. It is available in different orifice sizes allowing the designer to optimize system performance, thereby achieving a very efficient installation. The Model G4A Concealer" is a UL Listed Quick Response Concealed sprinkler intended for use in accordance with NFPA 13. FM Approves this sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2 -8N. Product Description The Reliable Model G4A Concealer uses a proven quick response fusible element in a standard style sprinkler frame with a drop -down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides ' /z" (13mm) of cover adjustment. The flat cover plate is attached to the skirt using 1357 (57 °C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus exposing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop -down deflector is properly located below the ceiling. CP Do m The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York, 10552 Installation Do not install the G4A Concealer in ceilings which have positive pressure in the space above. • Cut a Z inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model G4 Wrench, The wrench has drive tangs which insert into the cup slots. When installing a sprinkler the wrench is first positioned into the sprinkler /cup assembly until the wrench tangs engage the drive slots in the top of the cup (there are two sets of drive slots in the cup). The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler /cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER /CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceiling. A protective cap is provided to protect the drop -down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G4A Concealer` should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. Technical Data Ordering Information 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Assembly Finish 4. Inlet Type Cover Plate Finishes"' Standard Finishes Bronze Chrome Wh ite alnt Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Tempera Rating I� l Model G4 Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Classification Sprinkler Cover Plate Max. Ambient I Temp. Ordinary 165 °C 13FF/57 °C 1 100 °F /38 °C Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler Identifcation (SIN) US Metric Non Admustable 1 /2" 13mm 1 12" 15mm 5.6 80 1 /2" NPT RYz 1.2,3.4 R5415 Non Adjustable Yz" 13mm ' 11 mm 4.2 60 1 /2 "NPT RYz 1,2 , 4 R5413 Non A d'ustable Ye 13mm " 0 0mm 2.8 40 '/z "NPT R'' /z 1 R5411 Adjustable 1 Yz" 38mm '/2" 15mm 5.6 80 1" NPT Male or Female 124 R5418 Ad'ustable 1Yz" 38mm 11mm 4.2 60 1" NPT Male or Female 1,2 4 R5413 Adjustable 1' /2" 38mm ) (10mm) 2.8 1 40 1" NPT Male or Female 1,2,4 R5412 '•. v2• ftWC.V Fa OR ELWW i - -IT11 I i TR i aS L R CUP _ ,f 7 J /B' 90. 19 r FACE Or f'r✓"G r0 CUM MwwA .WX. f26 COWR ASSENBIY � COYER a0.lU$/IE"r J 5116 Fig.1 - 1 12" NPT Non - Adjustable Inlet I Fig. 2 - 1" NPT Male- Adjustable Inlet Fig. 3 - 1" NPT Female- Adjustable Inlet 9 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b Rell able e T{ I' T _ J Ir �r I �� - I = �JI9J ! ! 111E J =__ Wx.KLU "3ME"r i 4 r�f �MK & GN � P ��'[[ N I� NP:< Snu� � 3 �— n vv E"SiOi. The Reliable Automatic Sprinkler Co., Inc. (800) 431 -1588 Sales Offices (800) 848 -6051 Sales Fax (914) 668 -3470 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in USA 05/05. P/N 9999970150 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pi Nominal Pipe Size (in) 1 1 -1 /d Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot -dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. O.D. 1. D. Nom. Wall Weight/Ft Bundle (in) (in) (in) 2.375 Size 1.315 1.097 0.109 1.40lbs /ft 91 1 R R n 1 lilt) n In (I 1 o-1 I L.., r# r1 4 1 -1/2 1.900 1.682 0.109 2.08lbs /ft 61 70 2 2.375 2.157 0.109 2.64lbs /ft 37 51 L- I /L L.0 t Z) L.b155 U. 12U 3 3.500 3.260 0.120 4 4.500 4.260 0.120 3- b3lbs /ft 30 4.33lbs /ft 19 5.62lbs /ft 19 Schedule 40 Pi Nominal Pipe Size O.D. I.D. Nom. Wall Weight/Ft Bundle (in) (in) linl linl ciao 1 -1/2 1.900 1.610 0.145 2.72lbs /ft 44 2 2.375 2.067 0.154 3.65lbs /ft 30 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. /1819 Clarkson Road For additional information, c �� us Chesterfield, MO 63017 contact your salesperson today at J BULL MOOSE TUBE COMPANY (800) 325 -4467 (800) 325 -4467 or (636) 537 -2600 LISTED CJ FAX: (636) 537 -2645 in the USA, or from Canada www.bullmoosetube.com call (800) 882 -4666 FM A CR 8 O company e -mail: info n bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation 02/03 1 1.315 1.049 0.133 1.68lbs /ft 70 1 -1/4 1.660 1.380 0.140 2.27lbs /ft 51 1 -1/2 1.900 1.610 0.145 2.72lbs /ft 44 2 2.375 2.067 0.154 3.65lbs /ft 30 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. /1819 Clarkson Road For additional information, c �� us Chesterfield, MO 63017 contact your salesperson today at J BULL MOOSE TUBE COMPANY (800) 325 -4467 (800) 325 -4467 or (636) 537 -2600 LISTED CJ FAX: (636) 537 -2645 in the USA, or from Canada www.bullmoosetube.com call (800) 882 -4666 FM A CR 8 O company e -mail: info n bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation 02/03 Fig. 68 - Wide Throat Top Beam "C" Clamp w /Locknut Size Range — 3/8" thru 3/4" rod Function — For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals — Conforms to Federal Specification WW -H -171 E, Type 23 and Manufacturers Standardization Society SP -69, Type 19. Finish — Plain Note — Available in Electro- Galvanized finish. Order By — Figure number, rod size and finish Note — Do not over tighten set screw. Dimensions • Weights Rod Max. Rec. Approx. Size Load Lbs. Wt. /100 3/8 400 34 1/2 500 50 5/8 600 53 3/4 800 86 f• . K• ° �• r'r E r 0 �- °�.' .\ /•r Jam• /'` OFFICEIMANUFACTURING FACILITY - 1375 SAMPSON AVE. - CORONA, CA 92879 - PH: 951.737.5599 - FAX: 951.737.0330 CUSTOMER SERVICE - 800386.5266 www.tolco.com Fig Rod Stiffener Size Range — Sec 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to han rod for vertical seismic bracing. Approvals — Underwriters Laboratories Lis the USA (UL) and � Canada (cUL). Included in our Se ismic Restraints nn annr�vlsri Finish — Electro Galy r Note — Avail In HDG finish or Stainless Steel materials. Ord — Figure number -a i All Thread Rod Cut to Length Size Range — SecL 8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750 °F Finish — Plain Note — Available in Electro - Galvani d HDG finish or Stainless S aterials. Order By — F number, rod diameter, rod len finish Fig. 100 -All Thread Rod Full Lenqths Size Range — Secures 3/8" thru 7/8" rod in 10' lengths Material — Carbon Steel Maximum Temperature — 750 °F Finish — Plain Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions -Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650 °F 750 °F Wt. /100 1/4 240 215 12 3/8 610 540 29 112 117 1010 5 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3 360 169 1 4960 4420 222 1 '/4 8000 7140 360 1 1 h 11630 10370 510 Component of State of California OSHPD Approved C -LISTED Seismic Restraints Svste Dim nsi'6n - Weights —1�o_d Max. Rec. Load Lbs. Size For Service Temps 650 °F 750 °F 3/8 610 540 112 1130 1010 5/8 1810 1610 2710 2420 7/8 770 3360 OFFICE /MANUFACTURING FACILITY - 1375 SAMPSON AVE. - CORONA, CA 92879 - PH: 951.737.5599 - FAX: 951.737.0330 - CUSTOMER SERVICE - 800.786.5266 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general pipin purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2 ") Flared edges ease installation for all pipe types and protect CPVC plastic pipe fro abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2'/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjustinc nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8 ") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineerir Approved (3/4" thru 8 "). Conforms to Federal Specifications WW -H -171 E, Type 10 and Manufacture Standardization Society SP -69, Type 10. Maximum Temperature — 650 °F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTm Fig. 200WON. Order By — Figure number and pipe size Dimensions -Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 3'A 2 /a 400 11 1 1 /4 3/8 8mm or 10mm 3 2 400 13 1 1 h 3/8 8mm or 10mm 3� 2 400 14 2 3/8 8mm or 10mm 4� 3 400 15 3/4 3/8 8mm or 1Omm 3 2 400 11 1 3/8 8mm or 10mm 3 2 400 12 G UL US LISTED FM Zr° 3/6 10mm 5 4'A 600 27 3 3/8 1Omm 5 4 600 29 3 3/8 1Omm 7 5 600 34 4 3/8 10mm 7 5 1000 35 5 1/2 12mm 9�/8 6 1250 66 6 1/2 12mm 10/8 6 1250 73 8 1/2 12mm 13 8 1250 136 OFFICEWANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.toico.com — r I uw v nv�i i rirc EL E Anchoring Systems 4.3.6 1 HDI -P Drop -In Anchor 4.3.6.1 Product Description The Hihi HDI -P Drop -In anchor is an internally threaded, flush mounted expansion anchor for solid and hollow concrete. Product Features • Optimized 3/4" anchor length to allow reliable fastenings in hollow core panels, precast plank & post tensioned slabs • Shallow drilling enables fast installation • Lip provides flush installation, consistent anchor depth and easy rod alignment • Setting tool leaves mark on flange when anchor is set properly to enable inspection & verification of proper expansion Guide Specifications Expansion Anchor. Expansion anchors shall be flush or shell type and zinc plated in accordance with ASTM 8633, SC 1, Type Ill. Anchors shall be Hilti HDI -P anchors as supplied by Hilti, Inc., Tulsa, OK. Installation: Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits. Install anchors in accordance with manufacturer's recommendations. Listings /Approvals Approvals • Factory Mutual (FM) • International Conference of Building Officials (ICBO ES) Evaluation Report No. 5264 • City of Los Angeles (COLA) Research Report No. 25350 4.3.6.2 Material Specifications HDI -P Carbon Steel material meets the requirements of AISI 111 OM orAlSl 1010 Zinc plated for corrosion protection in accordance with ASTM B633, SC 1, Type III 4.3.6.3 Technical Data HDI -P Specification Table Description Length in. (mm) Bit Size in. Average Ultimate Loads, lb (kN) Allowable Loads, lb (kN) 4000 psi (27.6 MPa) Concrete Hollow Care 4000 psi (27.6 MPS Concrete Hollow Care Tension Shear Tension Shear Tension Shear Tension I Shear HDI -P 3 /8 3 /4 (19.1) 1 /2' 1900 (8.5) j 3000 (13.3) 2100 (9.3) 14000 (17.8) 380 (1.7) 600 (2.7) 420 (1.9) J 800 (3.6) 4.3.6.4 Installation Instructions see \S M 1. Set depth gauge 2. Hammer -drill 3. Clean hole. 4. Insert anchor. 5. Insert setting tool and 6. Collar of setting tool will on drill. hole. strike with hammer leave an indentation on until anchor is fully set. flange of anchor when 4.3.6.5 Ordering Information property expanded. HDI -P Products Setting Tools for HDI -P Anchors Description Item No. Box Qty HDI -P 3 /a 00243554 100 Description Item No. HSD -G 3 /e" — 3 /4" Setting Tool w/ hand guard 00247776 HST -P 3 /8" — 3 /4" Setting Tool 00253784 174 U5: 1 -SOD- 879 -8000 / www.us.hilti.com I Hilti Product Technical Guide 2002 1 Canada: 1- 800 - 363 -4458 / www.ca.hilti.com