HomeMy WebLinkAboutM10-0191 1
3
k
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
{
I TOWN OFVAIL
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
1 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
1
4
MECHANICAL PERMIT Permit #: M10 -0191
1 ASFR Project #: PRJ10 -0568
Job Address: 4800 MEADOW DR VAIL Status ...: ISSUED
i Location • Applied ..: 09/16/2010
s Parcel No...: 210112423010 Issued . . : 09/20/2010
Expires . .: 03/19/2011
1 OWNER MCILVAIN, MARIAN ASHTON & J. 09/16/2010
1966 NEWARK RD
1 LINCOLN UNIVERISITY
I PA 19352
APPLICANT JERRY SIBLEY PLUMBING 09/16/2010 Phone: 970 - 827 -5736
P.O. BOX 340
MINTURN
CO 81645
License: 152 -M
CONTRACTOR JERRY SIBLEY PLUMBING 09/16/2010 Phone: 970 - 827 -5736
i P.O. BOX 340
MINTURN
CO 81645
1 License: 152 -M
Desciption: REPLACE THE EXISTING FURNACE DUE TO A CRACKED HEAT
EXCHANGER AND ADD ONE CO DETECTOR.
i
Valuation: $2,100.00
1 ************************************************ *** *** * * * *** * * * *** * ******* * **** *FEE SUMMARY****************************************************** * * ****** *** ******** * *** * * ******
Mechanical Permit Fee - - -> $60.00 Will Call--- - - - - -> $4.00 Total Calculated Fees - -> $79.00
Plan Check— ----- -- - - - - -> $15.00 Use Tax Fee > $0.00 Additional Fees > $0.00
x Investigation - - -> $0.00 TOTAL PERMIT FEE - - -> $79.00
Total Calculated Fees - -> $79.00 Payments - -> $79.00
@{ BALANCE DUE--------> $0.00
APPROVALS
3 Item: 05100 BUILDING DEPARTMENT
09/20/2010 JRM Action: AP
Item: 05600 FIRE DEPARTMENT
i
CONDITION OF APPROVAL
Gond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315
g *************************************************************** * * *** * * * *** * * * *** *** *** * * * ***** ************************************************** * *** * * * *** * * * ***** * *** * * *******
s DECLARATIONS
1
1 I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
1 as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR I ■ - - _ • = • • c TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( I
AM - 4 PM.
/ I�� a 4 l
i S' natur- Ow r or Contractor D a
ii
i e, 7 ( Print Nar e
1
mechcanical_permit_041908
t
1 .
,
,
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: R100001345 Amount: $79.00 09/20/201003:32 PM t
Payment Method: Check Init: SAB i f
Notation: 32046 JERRY
SIBLEY
Permit No: M10 -0191 Type: MECHANICAL PERMIT
Parcel No: 2101 - 124 - 2301 -0
Site Address: 4800 MEADOW DR VAIL v
Location:
}
Total Fees: $79.00
This Payment: $79.00 Total ALL Pmts: $79.00
Balance: $0.00 t
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
Y
MP 00100003111100 MECHANICAL PERMIT FEES 60.00
PF 00100003112300 PLAN CHECK FEES 15.00
WC 00100003112800 WILL CALL INSPECTION FEE 4.00
1
f
f
1
1
f
x
1
t
1
I
1
8
i
i.
F
Y '
,
F
I
i.
i
S
4
E
I
SEP- ld- 2010(TUE) 01:25
P. 001/006
Boiler / Furnace & Fireplace Applications MUST include:
❑ Complete Mechanical Room Floor Plan with Dimensions
❑ Combustion Air Duct Size and Location
• Flue detail or Vent size, location & termination
• Gas Piping layout Including development length calculations
• Heat Loss Calculations
Project Street Aodre
(Number) (Street) _ 1 J (Suite 0)
B ild" /C I N • � 1Cr'aPn.� ���
❑ Boiler size & efficiency
o Equipment Cut Sheets for Fireplaces /Log Sets
Manufacturer's Info_ showing_ make, model & approval Ilsting)
Office Use: (� n
Project #: 1
Building Permit # _ - -
Mechanical Permit M M n 0 Lq
Lot" Block # Subdivision:
Define Scope and Location of Work: rz e
Contractor information: ;
P( VLe
Company: t�.-.
Company Address: j
54, l�R 3 �l6 A L� ,t�
co p; �� Q u
t o e-- 6�
City:
\ State: Zi I (use additional sheet if necessary) i
Contact Name: r (d �A I�YG- -- .._._- •- - - - - -- ____- __.___.. __ __----- -._.�_ _.._._� ._�
1 a Gas Piping Included
�� �Z f- Grs Piping by Others
Contact Phone E�' (�
E -Mail A. A ri Wood to Gas Fireplace Conversion
�
' 6PL n� c c"�
Town of Vail Contractor Registm ion yo.: �- ++e ovation_
E interior ( ✓) Exterior ( ) Other ( )
X
• Number of Existing Fireplaces: , -_ � �__....._._...__.. ,........_.........,._....._.,.
Contractor Signature (raqu d) i
_. _.._.. _..-- -• -�_- _ _-- ._ -___ ._ -- ------ •.. - -- . __ -... - ....... -_. _ E Gas Appliances Gas Logs Wood /Pellet
Property Information
Parcel tt: I G `� Z� ✓ tJ l0 Number of Proposed Fireplaces;
(For parcel 9, contact Eagle County Assessors Office at 970 - 328.8640 or i Gas Appliances Gas Logs Wood/Pellet
visit www.eaglecounty.us /patie) i_....._.,....,
Typo of Building:
_..... ..__,._._- ..__...- ._..___._.___
} `- - --
Tenant Name:
Commercial Properties) Restaurant (+/•t Duplex I ) Multi - Family ( ) Commercial ( )
Owner Name: (65a•tr G I �1lGti ,�► Restaurant { ) Other f )
-- Date
Complete valuation for Mechani armi (including fireplaces) 0 0
Mechanical S: �f a 0
�-� SEP 1 2010
a
C: Ncdevltbrtnslperniitq \huildinglmccltanie permit 010110
TOWN OF VAIL
MECHANICAL PERMIT
SEP- ld- 2010(TUE) 01:26
P. 002:'006
FORM NO. G11 -503
T J
kk J Y
/Y1
.r-7 '�..T° T.
p
1
P !
t 5
-8,11 www.Anenm.Covn
for canNele detBi&.'
RGRC- SERIES
Model with Input Rates
from 45,000 to 105,000 BTU/HR
[13.19 to 30.77 kW]
(All Models 95 %A.F.U_E.t)
C� ob-2 r
IS= 4 1141
/ su�
I I �
I
gama
CLASSIC
95% A.Fwu.
HIGH EFFICIENCY
FLOW
GAS FURNACES
The RheemO 95 %A.F.U.E. High Efficiency line of upflow gas
furnaces are designed for utility rooms, closets or alcoves.
The design is certified by CSA.
Features
a Heat exchanger Is constructed of all stainless steel for
maximum corrosion resistance and thermal fatigue
rellab`llty.
r Low profile "34 inch" design is lighter and easier to han-
dle and leaves room for optional accessories.
■ Left or right side gas, electric, and condensate drainage
connections on upflow models.
r intf,grated control board manages all operational func-
tions and provides hookups for humidifier and electronic
air cleaner.
* An insulated blower compartment, a stow- oponing gas
valve and a specially designed inducer systom make it
one of the quietest furnaces on the market today.
• Pre -paint galvanized steel cabinet.
• Molded permanent fliters.
a Optional indoor or outdoor combustion air. In addition.
combustion air may bo piped to either the top or side of
the cabinet on all upflow modols_ A special molded fitting
is provided to ease installation..
A Control Luse protection.
a )olld bottom is standard.
n Control board diagnostics.
A variety of cooling colas and plenums designed to use with
the Classic 95% A.F,)U.E. gas furnaces are available as
optional accessories for air conditioning models.
�A.F.W.E• Onr pAI FIIAI WKr atlCn FN69 !y) CAICUWA4 i ACCOtdanCe MItrp DeDbn Ale
01 E."OMY I98f DfOCOOkITAA.
5EP- 14- 2010(TUE) 01 :27 P.003i006
CLASSIC 95% A. F. U. E. HIGH EFFICIENCY
UPFLOW GAS FURNACE
DIRECT SPARK IGNITION &
REMOTE SENSOR
PRIMARYAND SECONDARY
HEAT EXCHANGER
PRESSURE SWITCHES
INTEGRATED
FURNACE
CONTROL
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: 409 and aluminized
409 stainless steel. secondary: 29 -4C stainless steel: induced draft; pressure
switches; redundant main pas control; blower compartment door safety switch;
solid state time on /off blower control; limit contras; manual shut -off valve;
100% safety lock out; cool fan oft delay; field selectable heat fan off delay; one
hour automatic retry; power and sell-test diagnostics; Wine sense current
diaonostics; electronic air cleaner connections; twinning (bullt -In) features;
humidifier connections; humidifier on /off delay: low speed continuous fan
option; single speed option for healing and cooling applications; pressure
regulator for natural and LP (propane) gasses: transformer: direct drive, multi -
speed blower motor. (Please note: a thermostat is not included as standard
equipment.)
IN -SHOT BURNERS
GAS VALVE AND
MANIFOLD
DRAFT INDUCER
OPTIONAL EQUIPMENT
Sldo and bottom filter racks; return air cabinet for a!1 sLes.
rjore; Furnace is not listed for use with fuels other than natural or UP.
(propane) gas.
All models can Do converted by a qualified distributor or local service dealer to
use L_P (propane) gas without changing burners - Factory approved kits must
be used to convert from natural to L.P. (propane) pas and may be ordered as
optional accussorl9s from a parts distributor.
For L.P. (propane) Operation, rotor to Conversion Kit Index Form.
2 Rheem Heating, Cooling and Water Heating
SEP- ld- 2010(TUE) 01:26 P 00d /006
UPFLOW MODELS
h
mml
9 /d 26
1 %s2' .—A
16 [7t3 mm) 15lmm
Ix• 1 l
(16 mm) B 115 14 D 20'
SUPPLY AIR -114" p" 1606 mm(
(19 mm(
. Q o ALT. COMBUSTION , 20bl,a [We mmi
AIR INLET
24r/fa 1815 MIMI
2" 51 mm DIA. KNOCKOUT
ALT. Gl>� CONNECTION
28e1e^
64
(8 mm) I [678 mm)
299la' pie� 1(22 mm DIA. KNOCKOUT
(756 mm( y AIT. ELECTRICAL CONNECTION
_
2T"Is �!e' (22 mm OW KNOCKOUT
1710(mm] ALT LOW VOLTAGE WIRING
J [265 mml 1 1 1 Je' 1 29 mm DIA. KNOCKOUT (361 mml
+ ALT. CONDENSATE DRAIN
1241 mmi
-- - - - - -- - - - - - - - J.
11'rpr _ Y3
mm, 1684 mml
FRONT 1291
2f;a11 a'
-- 1665 mml
ntGHT SIDE
INM>
RGRC- A
TOP
26'/,e'
D
E
(672 mm)
IEFr
S InE
MINIMUM CLEARANCE
2• [51 mml DIA.
SHIP
WkTS.
I gl
' RIGHT
SIDE
OAS CONNECTION.
23's/:v'
FRONT
VENT
DI
� /e' 22 mmj A, (�D3 mmi
17 [4451
16 [4151
ELERICAL CONNECTION
2 [51 ]
28Wa• (678 mm)
(HIGH VOLTAGES I
0
t 122 mml DIA.
2p /4^
1 1251
I L1A6E
1895 mml
111 [501
i, I
i WIRING
25
VENT"OUTLET
15' 1e 13971
(648 mm)
�
1 (29 mm] DIA.
0
0
CONDENSATE
1431e
COm18UST10N
i DRAIN (
1365 mml
AIR INLET
OPTIONAL RETURN AIR CUTOUT 1
11'12•
1282 mm(
—�
2 [51]
((EITHER SIDE) FOR USE WITH I
EXTERNAL SIDE FILTER FRAME
13 [352]
0
i�- 147 mml
F ._�...
1 [251
��� 26''Au'
940•
�.�
186.1 mml
1241 mml
C
LEFT SIDE
21511
18
h
mml
9 /d 26
1 %s2' .—A
16 [7t3 mm) 15lmm
Ix• 1 l
(16 mm) B 115 14 D 20'
SUPPLY AIR -114" p" 1606 mm(
(19 mm(
. Q o ALT. COMBUSTION , 20bl,a [We mmi
AIR INLET
24r/fa 1815 MIMI
2" 51 mm DIA. KNOCKOUT
ALT. Gl>� CONNECTION
28e1e^
64
(8 mm) I [678 mm)
299la' pie� 1(22 mm DIA. KNOCKOUT
(756 mm( y AIT. ELECTRICAL CONNECTION
_
2T"Is �!e' (22 mm OW KNOCKOUT
1710(mm] ALT LOW VOLTAGE WIRING
J [265 mml 1 1 1 Je' 1 29 mm DIA. KNOCKOUT (361 mml
+ ALT. CONDENSATE DRAIN
1241 mmi
-- - - - - -- - - - - - - - J.
11'rpr _ Y3
mm, 1684 mml
FRONT 1291
2f;a11 a'
-- 1665 mml
ntGHT SIDE
INM>
RGRC- A
B
C
D
E
F
IEFr
S InE
MINIMUM CLEARANCE
(IN.) [mml
SHIP
WkTS.
I gl
' RIGHT
SIDE
BACK
TOP
FRONT
VENT
04EM
17 [4451
16 [4151
15 [3971
2 [51 ]
15 (422]
13 13521
0
0
0
1 1251
2151
0
111 [501
06EM
17 14451
16 [4151
15' 1e 13971
2 [511
15 [422]
13'khz [3521
0
0
0
1 [251
2 [511
0
117 [53]
07EM
17 [445]
16 [415]
15 1397]
2 [51]
15 [422]
13 [352]
0
0
0
1 [251
21511
0
124 15
07ER
21 [5331
19 15041
19 1487]
21511
18
17 [441]
0
0
0
1 (25]
21511
0
137 [621
09EZ
10EZ
21 [533]
21 16331
19L [504]
19 (6041
19 [4871
19
2 [51]
2 (5t)
18 [511)
18 [5111
17l /32 144 11
17 14411 1
0
0
0
0 1
D
0
1 1251
1 [251 1
2 1511
2 [51)
0
0
148 (671
152 [691
4 Rheem Heating. Cooling and Water Heating
E 1 Designates Metric Conversions
BOTTOM
SEP- Id- 2010(TUE) 01:28 P.005r'006
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS UPFLOW MODELS
U.S. and Canadian Models
MODEL NUMBERS
RGRC- 04'MAES
RGRC- 06'MAES
RGRC -07 - MASS
RGRC- 07'RBGS
RGRC- 09 - 7JUS
RGRC- 10
HIGH FIRE INPUT BTU/HR [kW] W
45,000 [13.19)
60,000 [17.581
75.000 121.981
75.000 (21.98)
90.000 (26.381
105,000 (30.77]
HEATING CAPACITY BTU/HR [WJI
42,000 [12.311
56.000 [16.41]
'0.000 12.0 511
70,000 [20.51 ]
64,000 (24.621
100.000 129.271
HIGH ALTITUDE OUTPUT AT 8000'
28,458 18.341
37,944 111.121
47,430 (131t101
47,430 [13.90[
56.915 [16.69)
66,402 [19.461
HIGH FIRE) [kWI
BLOWER (DxW)
11x7
11x7
11x7
1201
12x11
12x11
[mml
[279 x 1781
[279 x 1781
[279 x 178;
[305 x 2791
[305 x 27
[305 x 2791
MOTOR H.P. [W]-
1 12 [373] -4 -PSC
4z 13731 -4 -PSC
I/-, (3731 -4 -PSC
1 12 [373] -4 -PSC
3 /4 [5591.4 -PSC
7 14 [5591 -PSC
TYPE
MOTOR FULL LOAD AMPS
6.8
6.8
68 ^
6.8
9.5
9 -5
HEATING SPEED
MED -LO
MED -HIGH
MED - HIGH
ME -HIGH
MED -HIGH
MED -HIGH
COOLING SPEED
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
MINIMUM EXT, STATIC PRESSURE
.10 [.025]
_
.12 [.029)
12 [.029]
.12 [.029[
.15 [.0371
.20 [.0491
(IN. W.C.) [kPa1
MAXIMUM EXT, STATIC PRESSURE
50 [ 124]
50 [.1241
5U (.1
.50 [.1241
.50 [.1241
.50 {.1241
(IN. W.C.) [kPa1
HEATING CFM 0.2' [.049 kPa]
885 [417]
845 [398J
1050 [4951
1500 [7081
1640 (7741
1445 [682]
W.C. E.S.P. (Us►
COOLING CFM 0.5' [.124 kPal
1195 [564]
1100 [5191
1110 (524]
1600 [7551
1820 [859]
1810 [8541
W.C. E.S.P. [Us]
TEMPERATURE RISE -HIGH FIRE
30.60
40 -70
40-70
30 -6G
35 -65
50-80
RANGE IN DEGREES *F ['C]
[16.7 -33.3)
122.2 -38.91
(22.2.38.9]
[16.7 -33.31
[19.4 -36.1]
[27.8.44.4]
RETURN AIR CABINETS (OFT.)
C17B
C178
C179
C219
C218
C21
RXGR-
(2) 12'x 16'
(2) 12'x 16'
(2) 12' x 16'
(2) 12' x 20'
(2) 12'x 20'
(2) 12' x 20'
FILTER SIZE
1305 x 4061
1305 x 4061
[305 x 40G]
1305 x 508]
1305 x 5081
1305 x 5081
[mm]
STANDARD, HIGH VELOCITY
15 3 14 x 25 x 1
15 x 25 x 1
15 1 /4 x 25 x 1
19 x 25 x 1
19'14 x 25 x 1
19 1 /4 x 25 x 1
PERMANENT FILTER (IN.)
_
APPROX. SHIPPING WEIGHT
111 [50.31
117 [53.1)
124 [56.2)
137 (62.11
148 (67.11
152 [68.91
(LBS.) lkal
AFUE 3
1 95.0%
95.0%
1 95,0%
95.0%
95.0%
1 95.0 a
NOTES: All models are 115V, 60HZ. 1 phase Gas connection size for all models is 1 12' (13 mml N.F.T.
d) Sea Conversion Kit Index Form for hlgh altitude derale.
(z Canadian Installations only.
CD In accordance with D.O.E. test procedures.
1-Standard
'N =NOx Models
MODEL IDENTIFICATION
O f! ( P
24F
Rheem Gas Upflowl Design
Furnace Condensing Series
Gas Furnace
Heating Input
Designation
Blower Size
M = 11 x 7
[279 x 176 mm]
R r 11 x 10
1279 x 254 rim]
Z 12 x 11
[305 x 279 mm]
Variations
A = Std.
Cabinet
6 - Wide
Cabinet
HeatfCool
Designation
E =1100 -1300 CFM
1519-613.5 Us]
6 = 1500.1700 CFM
["1 07.9 -802.3 L's]
J 1900 -2100 CF M
FuelCode
S = U.S, and
Canadian
Natural Gas
[896.7.991.1 Us]
[ ] Designates Metric Conversions
Rhesm Heating. Cooling and Water Heating
SEP- 14- 2010(TUE) 01:23 F 006:'006
BLOWER PERFORMANCE DATA* RGRC- MODELS
'Not applicable to heating speed.
Note: Unit tested without filters
[ ] Deslgnatos Metric Conversions
GENERAL TERMS LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which falls In normal use and service within the applicable
period stated, In accordance with the terms of the limited
warranty.
For Complete Detalla of the UmItad Warranty, Including ApplicableTerma
and Conditions. Soo Your Local Installor or Contact the Manufoctwnr for
a Copy.
Primary and Secondary Heat Exchanger ....... Limited Lifetime
Conditional Parts (Registration Required) .......Ten (10) Years
Parts ....................................... ..................... Fivo (5) Years
Rheem Heating, Cooling and Water Heating 5
BLOWER
MOTOR BLOWER
CFM Rlsl AIR DELIVERY
MODEL
SIZE
H.P.
EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPal
[mm]
SPEED
[W)
0.1 [.021
0.2 [.051
0.3 [.071
8.4 [.101
0.6 [.121
0.6 1.151
0.7 [.171
LOW
805 [380]
780 [368]
760 [3581
720 [340]
685 [323]
64S [3041
605 [285]
RGRC -04
11 x7
12
MED -LO
920 [434]
88514171
$5014011
j 810 [382]
775 [3651
730 [3441
690 [3251
EMAES
[279 x 178]
[373]
MED -HI
1140 [5361
1110 [5241
10851512
1045 [493]
1010 (47G)
950 [4481
890 [4201
HIGH
1360 [6421
1320 [6231
1280 [6041
1235 [5831
1195 [5641
1140 [5381
1080 [500]
LOW'
770 (3631
740 (3491
710 [3351
675 (318]
645 [304)
605 [2851
570 [2691
RGRC -06
11 x7
112
MED -1-0
880 [4151
845 [3981
i 815 [384]
790 [373]
76013561
715 [3371
670 [3161
EMAES
[279 x 178)
[3731
MED -HI
1060 [500]
1025 (4831
99014573
960 [4531
92514361
880 [415]
035 [3941
HIGH
1260 (594)
1215 (5 731
11751
1135 [5351
1100 1119
1 1040 [491 J
985 (465]
LOW'
780 [3661
745 [351)
710 [3351
675 [3181
640 (3021
595 [2811
555 [2611
RGRC -07
11 x7
112
MED -LO
880 [415)
35U0011
825 13891
785 13701
750 (3541
702 [3311
655 [3091
EMAES
[279 x 1701
[373]
MED -HI
1090 (5141
1050(40S]
101014771
970 [458)
92S(4361
87614131
825 (3881
HIGH
1300 [613]
1255 [5921
12.10 [571]
1160 [5471
1110 [524]
1055 (4981
1005 [4741
LOW'
1115 [5261
1091 [5151
106715041
1044 (403]
1020 [4811
98414641
948 [4471
RGRC -07
11 x 10
1/2
MED -LO
1326 [6261
131516211
I 1304 (6151
1270 [5991
1236 [5831
1197 15651
1157 [546]
ERBGS
[279 x 254]
[373]
MED -HI
1535 [7241
1512 17141
1 1488 [/021
1453 [8881
1418 [669)
1373 [648]
1327 [6261
HIGH
1765 (833)
1723 (81_31
1 ,'931
1639 [7
1596 [ 7531
1544 17281
1492 (7041
LOW'
1199 [5661
1183 [5581
__1 681
1 1167 (5511
1132 [534)
1097 (5181
1062 (5011
1025 [484]
RGRC -00
12111
314
MED -1.0
1442 [6811
1416 [6681
j 1390 (6561
1360 [6421
1320 [6271
1288 (608]
1247 [589)
EZAJS
[305 x 279]
[5591
MED -HI
1666 [7661
1637 1773
1 1606 [7581
1554 [7331
1501 [708]
1466 [6871
1407 (6641
HIGH
2040 [9631
1993 [9411
1 1946 [9181
1888 [8911
1829 [8631
1758 [630]
1686 (7961
LOW'
1230 [580]
1205 (5691
1160 [5471
1155 [5451
1130 [5331
1090 (514)
1050 [496]
GRC -10
12 x 11
3/4
MED -LO
1490 (703)
1445 f 682
1405 (663)
1375 [649]
1350 [6371
1295 [6111
12401585]
EZAJS
1305 x 2791
1559
MED -HI
1710 [8071
1665 [7861
1620 (765)
1570 (7411
1540 [7271
1475 [6961
1
1410 [6651
HIGH 1
2010 [9491
1955 [9231
1900 [897]
1a55 [8751
1810 [854]
1710 [8071
1610 [7601
'Not applicable to heating speed.
Note: Unit tested without filters
[ ] Deslgnatos Metric Conversions
GENERAL TERMS LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which falls In normal use and service within the applicable
period stated, In accordance with the terms of the limited
warranty.
For Complete Detalla of the UmItad Warranty, Including ApplicableTerma
and Conditions. Soo Your Local Installor or Contact the Manufoctwnr for
a Copy.
Primary and Secondary Heat Exchanger ....... Limited Lifetime
Conditional Parts (Registration Required) .......Ten (10) Years
Parts ....................................... ..................... Fivo (5) Years
Rheem Heating, Cooling and Water Heating 5
w
9 -22 -2010 Inspection Request Reporting Page 17
4:28 pm Vim, CO - City Of
Requested Inspect Date: Thursdayy Sepptember 23, 2010
Assigned To: JMONDRAGON
Inspection Type: MECH
Site Address: 4800 MEADOW DR VAIL
A/P /D Information
Activity: M10 -0191 Type: B -MECH Sub Type: ASFR Status: ISSUED
Const Type: Occu ancv: Use: Insp Area:
Owner: MCILVAIN, MARIAN ASHT & J. GIBSON, III
Contractor: JERRY SIBLEY PLUMBING Phone: 970 - 827 -5736
Description: REPLACE THE EXISTING FURNACE DUE TO A CRACKED HEAT EXCHANGER AND ADD ONE CO
DETECTOR.
Reouested Insoectionls
Item:
390 MECH -Final
Requestor:
JERRY SIBLEY PLUMBING
Comments:
827 -5736
Assigned To:
Action:
JMO N
Time Exp:
Requested Time: 03:00 PM
Phone: 970 - 827 -5736
Entered By: JMONDRAGON K
4 -� -
Inspection Histo
Item:
200 MECH -Rough
Item:
310 MECH - Heafing
Item:
315 PLMB -Gas Piping
Item:
320 MECH - Exhaust Hoods
Item:
330 MECH - Supply Air
Item:
340 MECH -Misc.
Item:
390 MECH -Final
REPT131 Run Id: 11960