HomeMy WebLinkAboutM10-0133 7 ! NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES TOWNOF Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT Permit #: M10 -0133 ACOM Project #: PRJ10 -0239 Job Address: 181 W MEADOW DR VAIL Status ...: ISSUED Location • VVMC Applied ..: 07/21/2010 Parcel No...: 210107101013 Issued . .: 09/20/2010 Expires . 03/19/2011 OWNER VAIL CLINIC INC 07/21/2010 IN CARE OF VAIL VALLEY MEDICAL CENTER PO BOX 40000 VAIL CO 81658 APPLICANT AMERICAN MECHANICAL SERVICES 07/21/2010 Phone: 877 - 637 -7397 GYPSUM OFC - 770 LINDBERGH DR 3231 S ZUNI ST ENGLEWOOD CO 80110 License: 128 -M CONTRACTOR AMERICAN MECHANICAL SERVICES 07/21/2010 Phone: 877 - 637 -7397 GYPSUM OFC - 770 LINDBERGH DR 3231 S ZUNI ST ENGLEWOOD CO 80110 License: 128 -M Desciption: REPLACE BOILER, (B3) Valuation: $154,500.00 *«++««+*+*+***««««+««:«+******+++++******«««++++ * * * ««+ + + + +++ + * * * * « « ««««+ + * * **** «FEE SUMMARY++++*«++++«+++******«+«+++**+****+++++«+****«+*++«««+++ + **** « * *«« « ++.++: : + * *** * * ++«+ ++ Mechanical Permit Fee —> $3,100.00 Will Call > $4.00 Total Calculated Fees - -> Plan Check----- ------ - - - - -> $775.00 Use Tax Fee > $6,9$0.00 $3,090.00 Additional Fees -- > $0.00 Investigation > $0.00 TOTAL PERMIT FEE - - -> $6,969.00 Total Calculated Fees - -> $6,969.00 Payments - - ----> $6,969.00 BALANCE DUE —> $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 08/31/2010 JRM Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 Cond: CON0011566 Submit plan to mitigate false alarm potential. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION HALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM -4 PM. 7/01/0 Signature of Owner or Contractor Date m ech ca n ica lie rm it_041908 Print Name m ech ca n ica l_pe rm it_041908 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001328 Amount: $6,969.00 09/20/201009:04 AM Payment Method: Check Init: SAB Notation: 61073 AMERICAN MECHANICAL SERVICES Permit No: M10 -0133 Type: MECHANICAL PERMIT Parcel No: 2101 - 071 - 0101 -3 Site Address: 181 W MEADOW DR VAIL Location: VVMC Total Fees: $6,969.00 This Payment: $6,969.00 Total ALL Pmts: $6,969.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts MP 00100003111100 MECHANICAL PERMIT FEES 3,100.00 PF 00100003112300 PLAN CHECK FEES 775.00 UT 11000003106000 USE TAX 4% 3,090.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 1 • r► N i , � g I ,' l s s n 'c ,, -, m r kr d 7 ''z ` ,° , ', S ` � t , uth Pr ntage' i ' ,:. 4 „ r e v.. - ' ' d , V • pota.* , • F ; tee ;' - . x * ..,, ; , ' 1 MECHANICAL PERMIT / li Boiler / Furnace & Fireplace Applications MUST include: / Complete Mechanical Room Floor Plan with Dimensions K Boiler size & efficiency V Combustion Air Duct Size and Location ❑ Equipment Cut Sheets for Fireplaces /Log Sets Flue detail or Vent size, location & termination (Manufacturer's info showing make, model & approval listing) { d Gas Piping layout including development length calculations Office Use: - ..,.. i7..) t e { ❑ Heat Loss Calculations Project #: 12 i Building Permit #: Project Street Address: I e1 (,J, (In Mechanical Permit bl 4 11 11 (Number) (Street) (Suite #) • ' . S Lot #: Bloc i � p Bu ilding /Complex Name: V' L V 4c�,,- f Define Scope and Location of Work: a me ✓E 35 Contractor Information: . 00 kEaL Le 3 o k a V-"44 1'1E6' Company: AmE+G( -Av / J�E ,oheaI 1244,CE.S ac (ootlfc. � r thvt� Z.-FR c:, e* A Company Address: 770 1.►.� (0e y runt P unt State: Co Zip: RI 37 (use additional sheet if necessary) City: G Contact Name: �RIC rilobE ❑ /Gas Piping Included ' Contact Phone: c 174 - 376 - 0 ✓ 4 0,7 ❑ Gas Piping by Others E -Mail Emo66 Ai►'�SBF USf7 • Cmtvr • ❑ Wood to Gas Fireplace Conversion Town of Vail Contractor Registration No.: 1� 8 - 1 Boiler Location: Interior ( O Exterior ( ) Other ( ) X Number of Existing Fireplaces: Contractor Signature (required) Gas Appliances _ Gas Logs Wood /Pellet Property Information Number of Proposed Fireplaces: Parcel #: ; 710101 1 D t0 ► 3 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or Gas Appliances Gas Logs Wood /Pellet visit www.eaglecounty.us /patie) Type of Building: Tenant Name: V R■L + '+C Z is Single- Family ( ) Duplex ( ) Multi - Family ( ) Commercial (Vr (Commercial Properties) Restaurant ( ) Other ( ) j Owner Name: Date Received: Complete Valuation for Mechanical Permit: (including fireplaces) Mechanical $: / `� 445W. a IS E D I JUL 20 2010 1 1 C: \cdcv \forms \permits\ building \mcchanical_permit_OI 0110 TOWN OF VAI L '$) 1 BEAU1N July 16, 2010 GANZE consulting engineers, inc. Mr. Eric Moberg Service Manager AMS Mountain Division 770 Lindberg Dr., #501 Gypsum, CO 81637 RE: Vail Valley Medical Center — Vail Hospital Boiler B -3 -3 Replacement Project #8739.08 Dear Eric: Boiler 3 in the main boiler plant at the Vail Hospital has expired and must be replaced. The expired boiler is a Weil McLain, dual fuel, cast iron section boiler with a listed efficiency of 80 %. This boiler was one of three boilers in common service providing heating water to much of the hospital. The two remaining boilers are relatively new and are still confidently in service. The proposed replacement boiler is a modulating Viessmann Vitorond 1080 dual fuel boiler with a rated efficiency of 85% for natural gas (primary service). Section 403.6 in the recently adopted Town of Vail Ordinance No. 18 requires that all boilers installed in the Town "shall have a minimum efficiency of ninety- two percent (92 %) AFUE ". We understand the intent of the code is to achieve reduced energy consumption and increased energy efficiency. Although the proposed replacement boiler would not meet the stated efficiency requirement, we feel the proposed replacement boiler solution is in alignment with the intent of the code. Boiler efficiencies above 86% are achievable using condensing boiler technology employed in a low temperature heating water system, wherein the boiler incoming water temperature (boiler return) is below 140 °F (typical condensing point). As the boiler incoming temperature decreases below 140 °F, boiler efficiency gradually increases. Although the efficiency curve for each boiler is slightly different, 92% efficiency is generally associated with a return water temperature of approximately 110 °F. Conventional heating water boiler systems, such as the existing main boiler plant system, are designed around heating water return temperatures of 160 ° - 180 °F, well above condensing temperature. The main boiler plant serves a majority of the hospital which includes a variety of heating terminal devices. Based on years of operational experience to achieve desired heating performance, this system is operated at a supply boiler water temperature of 200 °F (resulting in a return water temperature of about 180 °F) during winter and partial shoulder seasons and a supply temperature of 180°F (resulting in a return temperature of about 160 °F) during the remainder of the year. In summary, the operational needs for this boiler plant are well above condensing temperatures. As such, a boiler with a "listed" efficiency of 92% would only achieve a true efficiency in the mid- 80 °Fs. Therefore, we feel the proposed boiler solution aligns with the intent of the code for this installation. If you have any questions or comments, or if you need additional information, please call. <t it111itiiifi f iitlr� d0 II h, R E� 4 , Si. e ely, O. 1 KO ,/ • CtI : 35218 � i an Koelliker, P.E. 0�F•• Principal ' �' •`' - ' 10 E. kieaecr Creel B..u'.:+o d. Sri!., 202, 6% t3. Sax 050. ,re:. CO 01620 P . 0 a ce VAIL ALBUQUERQUE DENVER FORT COLLINS LAKE TAHOE SACRAMENTO VAIL ;, ,:sv ,i .._n arvsiLUU>x. www.bece.com