Loading...
HomeMy WebLinkAboutF10-0079TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Job Address: 680 LIONSHEAD PL VAIL Location.....: UNIT 605 Parcel No...: 210107206061 Project No OWNER WOODBURN COCKRUM TRUST- 10/04/2010 CAROL W. COCKRUM TRUSTEE 5398 NIGHT HERON DR BLAINE WA 98230 APPLICANT CASTLE FIRE SPRINKLERS PO BOX 3878 AVON COLORADO 81620 License: 735 -S CONTRACTOR CASTLE FIRE SPRINKLERS PO BOX 3878 AVON COLORADO 81620 License: 735 -S Permit # Status ... . Applied. . . Issued . . . Expires. .: F 10 -0079 ISSUED 10/04/2010 10/07/2010 INC. 10/04/2010 Phone: (970) 688 -0789 INC. 10/04/2010 Phone: (970) 688 -0789 Desciption: UPDATE EXISTING SPRINKLER SYSTEM TO ACCOMMODATE TENNANT IMPROVEMENTS TO UNIT 605. Valuation: $4,000.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ***************************** * *# * * * * * * * * * * * * * * * * * * * * * * * * * * ** Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > $602.00 Plan Check --- > $432.00 DRB Fee--------------- - - - - -> $0.00 Additional Fees------ - - - - -> ($31.00) Investigation -> $0.00 TOTAL FEES--------- - - - - -> $602.00 Total Permit Fee -------- —> $231.00 Will Call ----- > $0.00 Payments------------ - - - - -> $231.00 BALANCE DUE --------- > $0.00 # f #### rt f######### rt#### f############# f############## f f########} rt# rt############ rtrtrtf######### rt}#### ff####### #f # # # # # # # # # # # # # # # }f # #f # # # #f # # #rt Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 10/06/2010 mvaughan Action: AP as builts required to be submitted on pdf. CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. ###} ########### } ###### } ## } # 4 # f►###*## rti###### i##### irti# irti## f######## rt######### f####*###############*##### rt####### # # # # # # # } # # # ## } ## # # # #i # # # # # # } # #} DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SIGNATURE OF OWNER OR CO) RACTOR POR HIMSELF AND OWNER ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001517 Amount: $231.00 10/07/201003:02 PM Payment Method: Check Init: LC Notation: #1412 / CASTLE FIRE SPRINKLERS ----------------------------------------------------------------------------- Permit No: F10 -0079 Type: SPRINKLER PERMIT Parcel No: 2101 - 072 - 0606 -1 Site Address: 680 LIONSHEAD PL VAIL Location: UNIT 605 Total Fees: $231.00 This Payment: $231.00 Total ALL Pmts: $231.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 231.00 ----------------------------------------------------------------------- - - - - -- Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 -479 -2128 ' Fax: 970 -479 -2452 Web: www.vailgov.com - evelo ment Review C , . 1 , r w FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number S. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: 690 Vvest Lionshead Place (Number) (Street) Building /Complex Name: Thr_ Sn ioig Contractor Information: Company: Cast Fire Sprinklers, Inc. 605 (Suite #) Office Use: Project # Building Permit #. Sprinkler Permit #: Fl "— Lot M Block # Subdivision Company Address P.O. B ox 387 Clty: A v o n State: Co Contact Named Eric Schumacher Detailed Description of Work: Update existing sp syste Zip: 81620 to accommodate tennant improvements to unit 605 of the Contact Phone: 720.281 -2364 E -Mail castlefiredesign@gmail.com Town of Vail Contractor Registration No : 735 X Contractor Signature (required) Property Information Parcel #. 2101- 072 -06 -061 (For parcel u, contact Eagle County Assessors Office at 970 - 328 -8640 or visit w%w eagiecounty usrpabe) Tenant Name: Woodburn Cockrum T Owner Name: Carol W.B i nns &Cat Anne Cockrunn Dean Co- Complete Valuation for Fire Sprinkler Permit Fire Sprinkler S $4.000.00 -�� 1A 1 L `U e i P exi bui lding. (use additional sheet if necessary) Detailed Location of Work u Does a Monitored Fire Alarm Exist? Yes (x) No( ) Does a Sprinkler System Exist? Yes (x ) No ( Work Class: Ne: I I Add tion ( ) Remodel (x ) Repair ( ) Retro -F It ( ) Other( ) Type of Building: Single- Family ( ) Duplex ( ) Multi - Family ( ) Commercial ( ) Re Date Received: staurant ( ) umer (x ) D C E V OCT 0 4 2010 TOWN OF VAiL 01-170[)-10 CASTLE FIRE SPRINKLERS, INC. To whom it may concern, Castle Fire Sprinklers is requesting a permit to modify the existing fire sprinkler system located in Unit 605 of the Antlers Lodge in Vail Colorado in order to accommodate tenant improvem t. The work needed to be performed is the relocation of six automatic sprinkler heads and the additi of one sprinkler. The new sprinkler will match existing Tyco LFII Horizontal Sidewall. The piping to be used will match existing type M copper tube sized equal to or larger than existing pipe. The sprinkler coverage will not exceed the original design requirements. Do to previous conversations with Vail Fire no calculations are required. The address to the Antlers Lodge is 680 West Lionshead Place, Vail, CO 81657. If you have any questions or comments regarding this project please feel free to contact Stuart Thompson with Castle fire Sprinklers at 970 - 688 -0789. Thank you for your consideration. Eric Schumache Castle Fire Sprii 720 - 281 -2364 F 10 - 0079 970 - 688 -0789 CO #938 P.O. Box 3878, Avon, CO 81620 castlefiresprinkler @yahoo.com tLICO Flre & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 rapid response HOME FIRE SPRINKLER SYSTEM Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K- factor General Description The Tycog Rapid Response T°", Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers are decorative, fast response, frangible bulb sprin- klers designed for use in residential occupancies such as homes, apart- ments, dormitories, and hotels. When aesthetics and optimized flow charac- teristics are the major consideration, the Series LFII (TY2334) should be the first choice. vides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush mounting surface position. The adjust- ment provided by the Recessed Es- cutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY2334) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two - family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY2334) has a 4.4 (63,4) K- factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (TY2334) is intended for use in areas with finished walls. It employs a two -piece Style 20 Recessed Escutch- eon. The Recessed Escutcheon pro- IMPORTANT Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 WARNINGS The Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing%urisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY2334 DECEMBER, 2007 F TFP412 Page 2 of 6 TFP412 Components: WRENCH 1 Frame FLATS WRENCH 2 Button __4 FLATS 3 Sealing OP -OF- 0 Assembly Y DEFLECTOR 1/2" NPT 4 Bulb 5 Compression /"6"(11,1 mm) Screw NOMINAL 2 -7/8" DIA. 6 Deflector 6 5 4 2 I MAKE -IN (73,0 mm) * Temperature rating _ CENTERLINE is indicated on top } OF WATERWAY of Deflector. 7/16" 1 STYLE 20 (11,1 mm 3 RECESSED I 1 -112" ~ (38,1 ESCUTCHEON END -OF- mm) ESCUTCHEON DEFLECTOR 2 -1/8" PLATE SEATING BOSS (54,0 mm) �I SURFACE RECES FIGURE 1 SERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS MOUNTING SURFACE TOP -OF- CLOSURE DEFLECTOR TY2334 7/16" (11,1 mm) MOUNTING W( PLATE TII/ END -OF- DEFLECTOR 1/8" BOSS (3,2 mm) 1 -114" (31,8 mm) 112" (12,7 mm) 1" (25,4 mm) 1/4" (6,4 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER / WRENCH RECESS (END "A" USED FOR TY2334) FIGURE 3 W -TYPE 6 SPRINKLER WRENCH 7/16±1/8" (11,1±3,2 mm) FACE OF SPRINKLER FITTING WRENCH RECESS Y 2 -7/8" DIA. (73,0 mm) 2 -1/4" DIA. (57,2 mm) 1 PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W -TYPE 7 RECESSED SPRINKLER WRENCH TFP412 Technical Data Approvals: UL and C -UL Listed. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.4 GPM /psis / (63,4 LPM /bars /z) Temperature Rating: 155 °F /68 °C or 175 °F /79 °C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame . . . . . . . . . . . . . . Brass Button . . . . . . . . . . . . . Bronze Sealing Assembly . . . . . . . . . . . . . . . Beryllium Nickel w /Teflont Bulb . . . . . . . . . 3 mm dia. Glass Compression Screw . . . . . Bronze Deflector . . . . . . . . . . . Copper tDupont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Tyco® Rapid Response TM, Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers are UL and C -UL Listed for installation in accordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority Having Ju- risdiction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A, B, C, and D as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A, B, C, and D for NFPA 13D and 13R as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm /sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed with an end -of- deflector -boss to wall distance of 1- 3/8 to 6 inches or in the recessed po- sition using only the Style 20 Re- cessed Escutcheon as shown in Figure 2. In addition the top-of- deflector- to -ceil- ing distance is to be within the range (Ref. Table A, B, C, or D) being hy- draulically calculated. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the width of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 16 feet for a 16 ft. x 20 ft. coverage area). Installation The Series LFII (TY2334) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1,6 mm). A 112 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in Page 3 of 6 sufficient adjustment in an Escutcheon Plate by under- or over - tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Horizontal Sidewall Sprinklers must be installed in ac- cordance with the following instruc- tions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling with the front edge of the De- flector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W -Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series LFII Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the following in- structions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W -Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the wall has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. (Continued on Page 8) Page 4 of 6 TFP412 ELEVATION Maximum Maximum Coverage Spacing Minimum Flow (c) and Residual Pressure Area (a ) Width x Length ( Ft. x Ft. Ft. (m) Top -Of- Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top -Of- Deflector- To- Ceiling: 6 to 12 Inches (150 to 300 mm) (mxm) 155 °F /68 °C 175 °F /79 °C 155 °F /68 °C 175 °F /79 °C 12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) (3,7 x 3,7) (3,7) 8.7 psi (0,60 bar) 8.7 psi (0,60 bar) 8.7 psi (0,60 bar) 8.7 psi (0,60 bar) 14 x 14 14 14 GPM (53,0 LPM) 14 GPM (53,0 LPM) 14 GPM (53,0 LPM) 14 GPM (53,0 LPM) (4,3 x 4,3) (4,3) 10.1 psi (0,70 bar) 10.1 psi (0,70 bar) 10.1 psi (0,70 bar) 10.1 psi (0,70 bar) 16 x 16 16 16 GPM (60,6 LPM) 16 GPM (60,6 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (4,9 x 4,9) (4,9) 13.2 psi (0,91 bar) 13.2 psi (0,91 bar) 14.9 psi (1,03 bar) 14.9 psi (1,03 bar) 16 x 18 16 19 GPM (71,9 LPM) 19 GPM (71,9 LPM) 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) (4,9 x 5,5) (4,9) 18.6 psi (1,28 bar) 18.6 psi (1,28 bar) 20.7 psi (1,43 bar) 20.7 psi (1,43 bar) 16 x 20 16 23 GPM (87,1 LPM) 23 GPM (87,1 LPM) 23 GPM (87,1 LPM) 23 GPM (87,1 LPM) (4,9 x 6,1) (4,9) 27.3 psi (1,88 bar) 27.3 psi (1,88 bar) 27.3 psi (1,88 bar) 27.3 psi (1,88 bar) 18 x 18 18 23 GPM (87,1 LPM) 23 GPM (87,1 LPM) 23 GPM (87,1 LPM) 23 GPM (87,1 LPM) (5,5 x 5,5) (5,5) 27.3 psi (1,88 bar) 27.3 psi (1,88 bar) 27.3 psi (1,88 bar) 27.3 psi (1,88 bar) 18 x 20 18 26 GPM (98,4 LPM) 26 GPM (98,4 LPM) 26 GPM (98,4 LPM) 26 GPM (98,4 LPM) (5,5 x 6,1) (5,5) 34.9 psi (2,41 bar) 34.9 psi (2,41 bar) 34.9 psi (2,41 bar) 34.9 psi (2,41 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design Criteria Section for details. (d) Sidewall sprinklers, where installed under a ceiling with a slope greater than 0 inch rise for a 12 inch run to a slope up to 2 inch rise for 12 inch run, must be located per one of the following: Locate the sprinklers at the high point of the slope and positioned to discharge down the slope. • Locate the sprinklers along the slope and positioned to discharge across the slope. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR HORIZONTAL CEILING (Maximum 2 Inch Rise for 12 Inch Run) TFP412 Page 5 of 6 1 71 ELEVATION (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design Criteria Section for details.. TABLE B NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS AT THE HIGH POINT OF THE SLOPE AND DISCHARGING DOWN THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 12 Inch Run) Minimum Flow (c) and Residual Pressure (1) Two sprinkler design with the sprinklers at the high point of the slope and positioned to discharge down the slope. Maximum Maximum Coverage Spacing Area (a) Ft. Width x Length (b) Ft. x Ft. (m x m) (m) Top -Of- Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top -Of- Deflector- To- Ceiling: 6 to 12 Inches (150 to 300 mm) 155 °F /68 °C 175 °F /79 °C 155 °F /68 °C 175 °F /79 °C 12 x 12 12 1 23 GPM (87,1 LPM) I 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) (3,7 x 3,7) (3,7) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 14 x 14 14 1 23 GPM (87,1 LPM) I 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) I 23 GPM (87,1 LPM) (4,3 x 4,3) (4,3) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 16 x 16 16 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) (4,9 x 4,9) (4,9) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 16 x 18 16 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) (4,9 x 5,5) (4,9) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 16 x 20 16 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) (4,9 x 6,1) (4,9) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 18 x 18 18 1 23 GPM (87,1 LPM) I 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) 1 23 GPM (87,1 LPM) (5,5 x 5,5) (55) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 27,3 psi (1,88 bar) 18 x 20 18 1 26 GPM (98,4 LPM) 1 26 GPM (98,4 LPM) 1 26 GPM (98,4 LPM) 1 26 GPM (98,4 LPM) (5,5 x 6,1) (5,5) 34.9 psi (2,41 bar) 34.9 psi (2,41 bar) 34.9 psi (2,41 bar) 34.9 psi (2,41 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design Criteria Section for details.. TABLE B NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS AT THE HIGH POINT OF THE SLOPE AND DISCHARGING DOWN THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 12 Inch Run) Page 6 of 6 Care and Maintenance The Tyco® Rapid Response T^", Series LFII (TY2334) must be maintained and serviced in accordance with the follow- ing instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accord- ance with local requirements and /or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and /or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties ex- press or implied, including warranties of merchantability and fitness for a par- ticular impose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure TFP412 When placing an order, indicate the full product name. Contact your local distributor for availability.. Sprinkler Assembly: Series LFII (TY2334), K =4.4, Residen- tial Horizontal Sidewall Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155 °F /68 °C or Chrome Plated ......... P/N 51- 215 -9 -155 155 °F /68 °C White Polyester......... P/N 51- 215 -4 -155 155 F /68 - C Natural Brass........... P/N 51- 215 -1 -155 175 °F /79 °C or Chrome Plated ......... P/N 51- 215 -9 -175 175° F/79° C White Polyester......... P/N 51- 215 -4 -175 175 °F /79 °C Natural Brass........... P/N 51- 215 -1 -175 Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify') finish, P/N (spec- ify'). 'Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, P/N 56- 850 -4 -001. © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446