Loading...
HomeMy WebLinkAboutM10-0214Keenan Consulting Group Engineering Consultants 2174 South Broadway • Denver, Colorado • 80210 -4402 (303) 282 -9411 • FAX 282 -9412 • E -Mail: keenancg@keenancg.com May 3, 2011 Martin Haeberle Chief Building Official Town of Vail Department of Community Development 5 South Frontage Road Vail, Colorado 81657 RE: Woo Restaurant Village Inn Plaza 68 East Meadow Dr Vail, Colorado Permit No. B10 -0224 Dear Mr. Haeberle, The project mechanical installations were reviewed on April 26, 2011 by Ron Keenan. The following are comments from the review: • The Mechanical Installations are in compliance with the mechanical design. • Grease exhaust ducts are provided with access doors that will allow for cleaning the ducts. Location of clean out are sufficient for cleaning. The access doors and duct enclosures are in compliance with building code requirements, to the extent available for review. • Installation of hood exhaust fans was reviewed. Access for maintenance and servicing is provided. • Termination of hibachi exhaust ducts through tower sidewalls was reviewed. The ducts extend away from the tower walls to minimize grease accumulation on the walls. The termination complies with requirements of IMC section 506.3.12.2. • Operation of air distribution system was observed for excess draft. The air distribution was not objectionable. • The heating water boiler was not operational at the time of review. Piping modifications were being made for proper operation. The combustion air and gas vent installed were in compliance with the manufacturer listings. • The submitted air balance report has been reviewed and is accepted with the following comments: Hibachi 1 (EF -2) is 8.5% below design. Smoke tests were reported to have good capture exhaust flow. Hibachi 3 (EF -4) is 7.4% below design. Smoke tests were reported to have good capture exhaust flow. Hibachi 5 (EF -6) is 7.3% below design. Smoke tests were reported to have good capture exhaust flow. Hibachi 3 (EF -4) is 7.4% above design. The fan can be adjusted to reduce air noise, if it is objectionable. Installations are acceptable with our office. Installations concealed in building construction were not observed. If there are any questions or if we can provide any additional information please contact our office. Respectfully, onald D. Keena P.E. Keenan Consulting Group Copy: Rick Woo "rickwoo168 @yahoo.com" Roland Lee "rolandl @centurytel.net" 12380 Keenan Consulting Group, Inc. 2174 South Broadway Denver, CO 80210 M )o - C)a H I a /3 /io 303/282 -9411 303/282/9412 Fax keenancq @keenancc .com Transmittal 14 414 L Fax a Letter E:1 Drawings F Submittal El TO: �„/ r"jV JF€. , Date: z FIRM: [?)aJl 11P '�� ro lay) d@Srd6wt ids Phone #: 970- 844 e 6 359 (0) 17 0-904 , Go io 'c) Fax #: �70-73 - G4 Z. FROM: f `•tA Original to follow? Number of Pages _3 Including Cover Project. VA-t I_ , C"O . We are sending: # of Copies Items At ►N —\T 1 Gi r4 Comments: J G "w FEB 18 2011 J T04`JPJ OF JAIL 0 j,RjF,0* - ,AwLAt­ 7 ; 0 LAARS' NEOTHERM` RESIDENTIAL HYDRONIC BOILER NeoTherm Features: • Floor- standing condensing boiler • All connections are on top of unit • Stainless steel heat exchanger • Rated for alcove and closet installations • Easy to service • Will qualify for Energy Rebates • 95%+ AFUE • LAARS Integrated Control Systems' • Works with BAS Standard Equipment: • High condensing efficiency • Modulation down to 20% of full fire (5:1 turndown) • Sealed combustion chamber • Pre -mix metal fiber stainless steel burner • Low NOx system meets SCAQMD 2012 requirements the most stringent regulations for air quality • Horizontal or vertical direct vent • Horizontal vent and air terminals • Vent and air pipe lengths of up to 100 equivalent Feet (each) • Built -in condensate trap • Vent temperature cutoff feature • Spark ignition system • Stainless steel heat exchanger with welded construction (no gaskets) • ASME "H" stamp • Boiler circulator, mounted and wired inside jacket • 30 psi (207 kPa) ASME rated pressure relief valve FRONT VIBV • Temperature & pressure gauge • Drain valve • Controls multiple pumps for boiler, system and indirect domestic water heater, each with time delay • Indirect water heater priority (sensor sold separately) • Electronic PID modulating control • Large user - interface and display • Alarm output • Accepts external signal modulation control • Outdoor reset (sensor sold separately) • On /off toggle switch • Manual reset high limit • Burner site glass • Zero clearance to combustible surfaces • 12 year limited warranty '1_� 81:e Width_ HeI ht Depth In In In i Width 1 crn Height I cm 0• Ih I cm Connectlon3 I Weter I One Max Vent Len th CVPC 2" Die. 1 3" Din. 105 24 844 19 63 97 49 1" '/t' 40 it. 100 ft t! 24 844 19S/1 97 49 i' '/2' We 1001t. 210 24 38w 28 63 97 68 1" 4:' n/a 100 h. L A A e(` 800.900.9276 • FAX 800.559.1583 (Customer Service, Service Advisors) ma \ 20 Industrial Way, Rochester, NH 03867 • 603.335.6300 •FAX 603.335.3355 (Applicahwls engineering) Heating Systonag Company 1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • FAX 905.366.0130 ewwrorto WHITE' www. Litho in U.S.A. C Laars Heating Systems Co. 081' Doc. 1220 NwIl— . ,o.a w -h ad&PIM IN uw W vid vsnt mn KnR 21W411M 0" M ho P"MW Lin WW 45 MOHT BIDE VIEW BACK VIEW Project Sheet No. Of Date o N c�''i" t l.! G E...+.) 33 i ^l'� V �trt f"1 �`•+.�"! c� �L is PIV-4via" NST' \ojALL fi41U4 .,rte.. VvL 1� 4 11 F r% r r z-z FT 3 IF- - S 1 , 5 0 r r - FV -A-I., S fit- FAC Tr) ► Z. 4. • , 7 D 6'514 N T EIM F Al' = 7�'�- Z� °,� 15 GrpPi" v t2 ,vC_ t1t,tA W1 riu Z. U 1.13 cICA9K.s is , 49 \.JI "Paws 1 335 x I,13 1 i I; 9070's . S4 X . 49 X 9 :� �f4 L-r : (2z 9 3 G x 1/z. I /6o) Tlt� VAL .713 X 9� '1) 6 15TU4 k;otL f- t�_ C—AelI.C.1 ". 5 L 1 ti FLIT" / Snag o>u rf rr A fiL I ey p rr x. G74 s G7, z 3 z C A PAZ 1 TI , ra t M 1 14 5 t_ i M•I" T G7, - 4 - 5 M d o uv FU r ^ S 1 , 5 7 0 Fr Keenan Consulting Group Engineering Consultants NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ME OF VVAQ Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ACOM Job Address: 68 E MEADOW DR VAIL Location.....: UNIT 602, VAIL VILLAGE INN Parcel No...: 210108254031 OWNER VAIL VILLAGE INN INC 10/05/2010 100 E MEADOW DR VAIL CO 81657 APPLICANT PACIFIC AIR INCORPORATED 11207 WEST PROGRESS AVE LITTLETON CO 80127 License: 446 -M CONTRACTOR PACIFIC AIR INCORPORATED 11207 WEST PROGRESS AVE LITTLETON CO 80127 License: 446 -M 10/05/2010 Phone: 720-231-0346 10/05/2010 Phone: 720-231-0346 Desciption: INSTALL MAKE UP AIR UNIT, HOODS, GREASE DUCT, MAKE UP AIR DUCT, EXHAUST FANS. Valuation: $85,000.00 ALL TIMES Permit #: M10 -0214 Project #: PRJ10 -0221 Status ...: ISSUED Applied ..: 10/05/2010 Issued . .: 12121/2010 Expires. .: 04/03/2011 Mechanical Permit Fee ---> $1,700.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $2,239.00 Plan Check ------------------- > $425.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00 Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $2,239.00 Total Calculated Fees - -> $2,239.00 Payments ----- — ---------- > $2,239.00 BALANCE DUE --------- > $0.00 # # # # # # # # # # # # # # # # # # * # # # * * * * # * * # # * # # # # # # # # # * # # # # # # # * # # # # # # # # # # # # # # # # # # # # * * * * * * * * * * * # * # * # # * # # # # # # # # # # # # # # # * # # * * # # # # # # # # # # # # # # # # * # * # # # # # # # * # * # * # * * # # # * * * * * * # * * * * * # # * # * * # # # # # * # # # # # # # # * * # * # # # * APPROVALS Item: 05100 BUILDING DEPARTMENT 10/05/2010 DRHOADES Action: AP OK TO APPROVE PER CHRIS G. PLANS SUBMITTED /APPROVED WITH BUILDING PERMIT. Item: 05101 BUILDING DEPT REVISION 12/11/2010 Martin Action: AP Item: 05401 PLANNING DEPT REVISION 12/20/2010 RFD Action: AP Item: 05600 FIRE DEPARTMENT 12/09/2010 mcgee Action: CR revision dated 12/01/2010 EF 8 exhaust duct throught the wall is too close to the door at that elevation. Clouded revisions are beyond Fire dept review. 12/13/2010 McGee Action: AP Revised on verbal notification from Martin Haeberle that the exhaust duct is Class 3 and is 3 ft. away. # * # # # # # # * # # # # # # # # # # # # # # # # # # # # * # # # # # # # # # * # * # * # # * # # # # # # # # # # # # # # # # # # # # # # # * # # * * * * * # * # * # # # # # # # # # # # * # * # # # * # * # # # * # # # # # # # # # # # # # # # # # # # # # * * # # # # * * * # # * * * # * * * * # * # * * # * # # # # * # * * # # # # # # # # # # # # # # # # # # # # # # # # CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information mechcan ical_permit_041908 as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:O1 Signature of Owner or Contractor Print Name i 2I / / (D Dat mechcan ical_permit_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R100002041 Amount: $110.00 12/21/201003:49 PM Payment Method: Check Init: SAB Notation: 3146 JRW COMAPNY /DBA MAY PALACE CHINESE REST. ----------------------------------------------------------------------------- Permit No: M10 -0214 Type: MECHANICAL PERMIT Parcel No: 2101 - 082 - 5403 -1 Site Address: 68 E MEADOW DR VAIL Location: UNIT 602, VAIL VILLAGE INN Total Fees: $2,239.00 This Payment: $110.00 Total ALL Pmts: $2,239.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 110.00 - w r \'yr7: ent,of Community Development-`; x` - -- 75 South Frontage Road Vail,,Colorado 0' 5T °} Tel: _, 970 479- 2'121' Fak:.970- 479 -252 Web. "VWw.vailgov.corn, erg Review Coordinator , Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: Attention: f�j�eetEt _ () Revisions () Response to Correction Letter _attached copy of correction letter () Deferred Submittal ( ) Other Project Street Address: (0 � Description / List of Changes: (Number) (Street) (Suite #) (_eAL ( Building /Complex Name: VIL.LPAr- dam Lai.* Contact Information: Company: Company Address: _ City: \��. State: Zip: Contact Name: ` , - W 0­0 Contact Phone: 3 6 7 — 'jL- f q —QG2 0 p E -Mail Valuations (Labor & Material)) Building: Plumbing: Electrical: Mechanical: ? Total: (use additional sheet if necessary) Date Received: ,I DEC o 12010 TOWN O�_ 1- Sep -09 TRANSMITTAL FORM NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ACOM Job Address: 68 E MEADOW DR VAIL Location.....: UNIT 602, VAIL VILLAGE INN Parcel No...: 210108254031 OWNER VAIL VILLAGE INN INC 10/05/2010 100 E MEADOW DR VAIL CO 81657 APPLICANT PACIFIC AIR INCORPORATED 11207 WEST PROGRESS AVE LITTLETON CO 80127 License: 446 -M CONTRACTOR PACIFIC AIR INCORPORATED 11207 WEST PROGRESS AVE LITTLETON CO 80127 License: 446 -M 10/05/2010 Phone: 720-231-0346 10/05/2010 Phone: 720-231-0346 Desciption: INSTALL MAKE UP AIR UNIT, HOODS, GREASE DUCT, MAKE UP AIR DUCT. EXHAUST FANS. Valuation: $85,000.00 Permit #: M10 -0214 Project #: PRJ10 -0221 Status ...: ISSUED Applied..: 10/05/2010 Issued . .: 10/05/2010 Expires. .: 04/03/2011 ««*«*#«««*««##«««##«««««««««#««««««««««««««««««* « * * **« * * * **# « * * *** * * * **« « * « ««*# « FEE S * * *** « « * *#* « « « ««* * * « ««*« * «««« «# Mechanical Permit Fee —> $1,700.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $2,129.00 Plan Check --- – -------------- > $425.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00 Investigation ------- -- ------ > $0.00 TOTAL PERMIT FEE - -> $2,129.00 Total Calculated Fees - -> $2,129.00 Payments --- ---- - - - - -> $2,129.00 BALANCE DUE — ---- –> $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 10/05/2010 DRHOADES Action: AP OK TO APPROVE PER CHRIS G. PLANS SUBMITTED /APPROVED WITH BUILDING PERMIT. Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision code review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION E MAD -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. ture of Owner o or Date f n 1)19 U X*- A—r-V A nt m e ch ca n i ca I_pe rm it_041908 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001480 Amount: $2,129.00 10/05/201003:35 PM Payment Method:Credit Crd Init: SAB Notation: VISA LARRY ROMERO ----------------------------------------------------------------------------- Permit No: M10 -0214 Type: MECHANICAL PERMIT Parcel No: 2101 - 082 - 5403 -1 Site Address: 68 E MEADOW DR VAIL Location: UNIT 602, VAIL VILLAGE INN Total Fees: $2,129.00 This Payment: $2,129.00 Total ALL Pmts: $2,129.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- MP 00100003111100 MECHANICAL PERMIT FEES 1,700.00 PF 00100003112300 PLAN CHECK FEES 425.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 " g M, t Department of Community Development 8 8 P u }_ 75 South Frontage Road ail,.Colorado 81657 Tel: 970 -479 -2128. �, .. Fax: 970- 479 -2452 " - f Web: Www,vailgov.corn - - Development Review Coordinator 41 MECHANICAL PERMIT Boiler / Furnace & Fireplace Applications MUST include: ❑ Complete Mechanical Room Floor Plan with Dimensions ❑ Combustion Air Duct Size and Location ❑ Flue detail or Vent size, location & termination • Gas Piping layout including development length calculations • Heat Loss Calculations Project Street Address: 68 9:� i , nEt; oo v (Number) (Street) (Suite #) ❑ Boiler size & efficiency ❑ Equipment Cut Sheets for Fireplaces /Log Sets (Manufacturer's info showing make, model & approval listing) Office Use: Project #: �VL ( L — C7 Building Permit #: V5 tC) 0Z- Mechanical Permit #: M I [i -- Leal y Lot #: Block # Subdivision: Building /Complex Name: Define Scope and Location of Work: .1N'57?f Z-L 41 Contractor Information: Company: Pfic -iFIC 1449 -T/VC • . 4EK U/V �i , ,e,�oeAS 6 O vcT Company Address: 20 W64 1e669"T , ln(_ArQ 1)yC City: / L - trC#_ V Ai State: � �I� ZZiip D : v® (use additional sheet if necessary) KK Contact Name: " Y K n 0A1_ � n / ❑ Gas Piping Included Contact Phone: ?oa ' c�.� r y ❑ Gas Piping by Others E -Mail L s3 R 0/n (, 9 d 5 ® 4 ao6 ❑ Wood to Gas Fireplace Conversion Town of Vail Contractor R stra ' No.: �� Boiler Location: Interior (x) Exterior (x) Other ( ) X Number of Existing Fireplaces: Ce!�p r Sign re ( qui _.._ ._ Gas Appliances Gas Logs Wood /Pellet Property Information Parcel #: Number of Proposed Fireplaces: (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or Gas Appliances Gas Logs Wood /Pellet visit www.eaglecounty.us/patie) r Tenant Name: Woo (Commercial Properties) Owner Name: )(1CA 1y0 0 Complete Valuation for Mechanical Permit: (including fireplaces) Mechanical $: ®® ck C: \cdev\ forms\ permits\ building \mechanical _permit_010110 Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial (�l) Restaurant �6 Other ( ) Date Received: p LC�IE 0ML D OCT 0 2010 TOWN OF VAIL 05 -04 -2011 Inspection Request Reporting Page 19 4:51 Dm Vail, CO - City Q Requested Inspect Date: Thursday, May 05, 2011 Inspection Area: CG Site Address: 68 E MEADOW DR VAIL UNIT 602, VAIL VILLAGE INN A/P /D Information Activity: M10 -0214 Type: B -MECH Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: Insp Area: CG Owner: VAIL VILLAGE INN INC Contractor: PACIFIC AIR INCORPORATED Phone: 720 - 231 -0346 Description: INSTALL MAKE UP AIR UNIT, HOODS, GREASE DUCT, MAKE UP AIR DUCT, EXHAUST FANS. Requested Inspection(s) Item: 390 MECH -Final Requestor: PACIFIC AIR INCORPORATED PNN (30N Entered By: Time Exp: ► i A Y i on ansul to be done make up air to activate with type 1 hoods / thermal censor or approved means to activate main kitchen hood. Shroud up op main hood exhaust to devert exhaust away from building Balance test Requested Time: 04:00 PM Phone: 720- 231 -0346 plans to reflect changes . habachi hoods to operate seperatly" min 6" from hood edge to applainac, might not be all of the corrections required or Identified Inspection History JMONDRAGON K Item: 200 MECH -Rough ** Approved ** 12/20/10 Inspector: sgremmer Action: APCR APPROVED /CORRECTION REQD Comment: Checked main trunk line against plans that were provided at job please verify that those plans have been submitted and approved by the town. 12/29/10 Inspector: JRM Action: DN DENIED Comment: PLANS DO NOT REFLECT WHAT IS BUILT. SUBMIT NEW PLANS OR BUILD ACCORDING TO APPROVED FIELD SET. 01/05/11 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: APPROVED MAKE UP AIR DUCT WORK APPROVED HOOD HANGERS UPON STRUCTURAL DESIGN APPROVAL FROM ENGINEER 01/21/11 Inspector: sgremmer Action: PA PARTIAL APPROVAL Comment: Light tested 3 seperate bodies of the grease duct need to see three joints after the duct is installed plus the end cap 02/02/11 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: APPROVED LIGHT TEST ON ALL VERTICALS (6) HABACHI GREASE DUCTS 02/02/11 Inspector: sgremmer Action: PA PARTIAL APPROVAL Comment: Exterior risers 02/09/11 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: APPROVED 4 HORIZONTAL DUCT (GREASE DUCT) FROM HABACHI GRILLS (20 FT ON THE SOUTH SIDE DUCT 15 FEET OF DUCT LOCATED ON THE NORTH SIDE) 02/10/11 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: GREASE DUCT NORTH SIDE HORIZONTAL THRU EXTERIOR WALL, KITCEHN GREASE DUCT (1 HOOD CONNECTION STILL NEEDED) 02/16/11 Inspector: JRM Action: PA PARTIAL APPROVAL REPT131 Run Id: 13048