Loading...
HomeMy WebLinkAboutD10-0008TOWN OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-213 8 Job Address: Location.......: Parcel No....: DEPARTMENT OF COMMUNITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES DEMO. OF PART/ALL BLDG 2335 BALD MOUNTAIN RD VAIL BALD MTN TH G 15 210103302015 ': OWNER BLAZEK, MARGARET A. 2335 BALD MOUNTAIN RD 15 VAIL CO 81657 , APPLICANT HAPPY HAMMER CARPENTRY PO BOX 70 601 MAIN ST MINTURN CO 81645 License: 1063-B ' CONTRACTOR HAPPY HAMMER CARPENTRY PO BOX 70 601 MAIN ST MINTURN CO 81645 License: 1063-B Permit # D10-0008 Project # ?? Status . . . : ISSUED Applied .. . : 08/12/2010 Issued . . . : 10/11/2010 Expires.....: 04/09/2011 08/12/2010 Phone: 970-476-0625 08/12/2010 Phone: 970-389-1216 08/12/2010 Phone: 970-389-1216 ' Desciption: ADD LOFT ,INTERIOR REMODEL ,BATH IMPROVEMENTS Occupancy: R2 Type Construction: VB Valuation: $3,000.00 Revision Valuation: ?? Total Sq Ft Added 0 *ss*�**sss*asa�**�s�*►*sss*+**�*►****s*s*****a*****a****s*********s� FEE S UMMARY rrrs*ss*�**a*�**�*�*�a*sa***�+s*�:�r�*ss�+*�*�#s��s+sr*ss*ss Building----> $ B 3. 2 5 Restuarant Plan Review--> $ o. 0 0 Total Calculated Fees--> $14 i. 3 6 ' Plan Check--> $54. 11 Recreation Fee------------> $0 . 00 Additional Fees--------> $0. 00 Investigation-> $ 0. 0 o TOTAL FEES----------> $141. 3 6 Total Permit Fee--------> $141. 3 6 Will Call----> $4.00 Payments---------------> $141.36 BALANCE DUE--------> $0. 00 . ###f####f####�R#i#�kt####t#}####�F4/iRf##f########}f#f#########k###}##f#####}#}##t####i##�F}#�########t##########f#######}#****tt*#*#*i*#�Ft######tR## Approvals: i Item: 05100 BUILDING DEPARTMENT 09/14/2010 JRM Action: AP .....,:..::.+:::.*:.::.:.*:.:.:.*..*:s�.:..*.:s:*:s.:..+.:........:..s+.....+....+...s�rs..+..++s...:.s+...+:........�..:�.�.�.*:.*.�.:...:.+....:. i. See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS [N ADVA1YE-E-�i''7'EL�PHONE AT 479-2149 OR AT OUR OFFICE FROM 5:00 AM • 4 PM. _,�� / i i OF OWNER OR COiVTRACTOR FOR HIMSELF AND OWNER ******************************************************************************************************** CONDITIONS OF APPROVAL Permit #: D10-0008 as of 10-11-2010 Status: ISSUED ******************************************************************************************************** Permit Type: DEMO. OF PART/ALL BLDG. Applicant: HAPPY HAMMER CARPENTRY 10/11/2010 Job Address: Location: Parcel No: 'r'SLIaC�:���►.j[� 2335 BALD MOUNTAIN RD VAIL BALD MTN TH C-15 [►� [ I j[ I�� Gi 17 i•l l�[.� Description: ADD LOFT ,INTERIOR REMODEL ,BATH IMPROVEMENTS Applied: 08/12/2010 Issued: To Expire: 04/09/2011 ***********************************************Conditions:************************************************ Cond: 38 (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY. AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT THE VAIL FIRE DEPARTMENT AT 479-2252. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. BUILDING APPLICATION Separate permits are required for electrical, plumbing, mechanical, Project Street A dr ,�3� J��� � e �s (Number) (Street) (Suite #) Building/Complex Name: .( )aXGY D� 1' l��l �� Contractor Information: Company: N10�pA,� jr �� (� � Company Address: P6 1 � �� City: �Y�� WI/t�� State: � Zip: �/ � 'i Contact Name: ,��� V�- �Z-Z'eiMi Contact Phone: �Q% D�.�C� l- �2 �6 � E-Mail Town of ail Contract egistration No.: X _ ontractor Sign ure (required) Property Information Parcel #: 210 f �30 �l S (For parcel #, contact Eagle County Assessors Office at 970-328-8640 or visitwww.eaglecounty.us/ atie) �/�Tenant Name: /� � Owner Name: ���" �jlt%e�� I � Z� � Valuations (Labor 8� Materials) Building: $ �� �G Plumbing: $ Electrical: $ Mechanical: (including fireplace) $ ar' Total: $ �i �� _____ _ _._. _ .. ._.. _ _ _... _..._.. _ _ ___._._._ Office Use: �(J n iJ �� Project #: �t� r�'�-� � DRB #: Building Permit #: V' d"` �� u O Lot #: Block # Subdivision: Detailed Scope and Location of Work: S� � /.�tT� (use additional sheet if necessary) Work Class: New ( ) Addition ( ) Remodel (✓) Repair ( ) Other ( ) Work Type Interior (�Exterior ( ) Both ( ) Type of Building: / Single-Family ( ) Duplex ( ) Multi-Family F ) Commercial ( ) Other ( ) Does a Fire Alarm Exist? Yes (,/j No () Monitored Alarm? Yes ( ) No ( � Does a Sprinkler System Exist? Yes () No (� #& Type of Existing Fireplaces: Gas Appliances Gas Log Wood/Pellet Wood Buming #& Type of Proposed Fireplaces: Gas Appliances Gas Log Wood/Pellet Wood Burning _ _ ...._... _ _ _ _ _ _ _ ....... _ _ . ._ _. _.. _: _ .. Date Received: O1-Jan-10 � ;-�.. Presented to: Mr. Sean Cozzens Happy Hammer Carpentry 601 Main St Minturn, CO 81645 Performed & Prepared by: Mr. Steve Shurtliff DS Consulting, Inc. PO Box 6864 Avon, CO 81620 (303) 378-1544 Project Details: DSC Project #: 2583 Conducted: August 2, 2010 Homeowner: Ms. Margaret Blazek �i Consu�tin � On August 2, 2010, Mr. Steve Shurtliff of DS Consulting, Inc. (DSC) performed a limited inspection and collected asbestos bulk-samples at 2335 Bald Mtn Rd, Unit 15, Vail, Colorado, in order to identify potentially hazardous friable and non-friable asbestos-containing materials (ACM) within a portion of the above-referenced, single family residence in which renovations are scheduled. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material (ACM) as a material containing more than 1% asbestos. Mr. Shurtliff performed asbestos bulk-sampling of two types of drywall (surfacing material) in a total of six (6) locations as well as cloth wall covering (miscellaneous material) in a total of one (1) location within the residence. Bulk-samples of drywall were collected within the stairwell to the main level, the main level dining room, the stairwell to the upper level and the upper level hot tub room (not currently being used as such). A bulk-sample of cloth wall covering was collected within the stairwell to the upper level. The bulk-samples were analyzed by Aerobiology Laboratory Associates, Inc. (NVLAP #200860-0) in Denver, Colorado. All laboratory results reporting as negative for asbestos (see Appendix B for laboratory results). 2 I. Introduction A limited inspection and bulk-sampling for ACM was conducted at 2335 Bald Mtn Rd, Unit 15, Vail, Colorado, by Mr. Shurtliff on August 2, 2010 at the request of Mr. Sean Cozzens with Happy Hammer Carpentry. Mr. Shurtliff is a Colorado State Certified Building Inspector; having EPA Accreditation #15413 (see Appendix A for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non-friable ACM within the residence in which renovations are scheduled. II. Structural Design The structure is a wood-framed, multi-level, single-family residence with attached garage. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a limited number of bulk-samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk-samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the EPA's Method ,for the Determination of Asbestos in Bulk Buildir�g Materrals (EPA 600/R/116, July, 1993) and the McCrone Research Institute's �'i►e Asbestos Particle At�as as methods references. Analysis of the bulk-samples was performed on the "date reported," as listed in the bulk-sample analysis report. 3 IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing Material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the sur€ace if the damage is evenly distributed (one-quarter if the damage is locaIized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: • The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). • One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. • Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response-action recommendations for asbestos-containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1% within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1% within the bulk-sample, or a bulk-sample in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a"TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1% unless it is analyzed by the point-count method to be less than 1%. V. Inspector Comments No asbestos-containicrg material (ACM) was identified during the bulk-sampling conducted at 2335 Bald Mtn Rd, Unit 15, Vail, Colorado. A total of six (6) bulk-samples were collected from drywall and cloth wall covering within the above-referenced residence. All bulk-samples tested negative for asbestos. 4 Vt. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent-asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at 2335 Bald Mtn Rd, Unit 15, Vail, Colorado, on August 2, 2010. The quantities are approximations and are subject to field verification: q ,q � • •"F �:�; ia �„- yv � �eR$ t�e�o� R � �� �1 { +�{ .Pq=4 � 7�, .f", �� Sample #: DW01-01 Sample #: DW01-02 Sample Description: Drywall Sample Description: Drywall Sample Location: Main Level Dining Room - Wall Sample Location: Stairwell To Upper Level - Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,OOOfC2 Material Quantity: <1,OOOft2 Material Condition: Good Material Condition: Good Physical Description (layers): White/tan drywall; Physical Description (layers): Brown resinous White compound w/white paint; White tape; material; White/tan drywall; White tape; White White 'oint com ound com ound w white aint; White 'oint com ound Asbestos Detected (layers): Negative; Negative; Asbestos Detected (layers): Negative; Negative; Ne ative; Ne ative Ne ative; Ne ative; Ne ative Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII : ,� ��� � � x,,�: r�. ���s �� � .��`� }` > '�- � .;• �r, &� Sample #: DW01-03 Sample #: DW02-01 Sample Description: Drywall Sample Description: Drywall Sample Location: Stairwell To Main Level - Wall Sample Location: Upper Level Hot Tub Room - Wall Material Classification: Surfacing Material Material Ctassification: Surfacing Material Material Quantity: <1,OOOftz Material Quantity: <1,OOOft2 Material Condition: Good Material Condition: Good Physical Description (layers): White tape; White Physical Description (layers): Not Analyzed compound w/white paint; White joint compound; White tan d all Asbestos Detected (layers): Not Analyzed Asbestos Detected (layers): Negative; Negative; Ne ative; Ne ative Recommendations: G�NERAL - See Section VII Recommendations: GENERAL - See Section VII 5 g; �'`",�:� ����¢,"���ti�.•'r+- "���^�'" � � :h .r'^'ea ""•('���'� .k` '''° ' `'a�� ,� �,ftf �«` 'fp°d"�,�,r_r �'�' r � rg" a.�' ��r '"u+s 4 a ..:vr rq„�.:..- �„� _ '�4<� '�"� �� ;�:� 4 C y .a ,r�,'S` �P u . � - ���� e ��?sz �" °s'� - Sample #: DW02-02 Sample #: DW02-03 Sample Description: Drywall Sample Description: Drywall Sample Location: Upper Level Hot Tub Room - Sample Location: Upper Level Hot Tub Room - Wall Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,OOOft2 Material Quantity: <1,OOOft2 Material Condition: Good Material Condition: Good Physical Description (layers): White joint Physical Description (layers): White joint compound; White compound w/white paint; compound; White tape; White compound w/white White ta e; White tan dr all aint Asbestos Detected (tayers): Negative; Negative; Asbestos Detected (layers): Negative; Negative; Ne ative; Ne ative Ne ative Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII � i �r.s`� a S �` q �'j�c.&a����`�{s8y�;, � r..��' ` ��< �. *ra t,� R�.rr, Sample #: MISC01-01 Sample Description: Cloth Wall Covering Sample Location: Stairwell To Upper Level - Wall Material Classification: Miscellaneous Material Material Quantity: <1,OOOft2 Material Condition: Good Physical Description (layers): Tan fibrous material; Yellow mastic; White fibrous woven resinous material Asbestos Detected (layers): Negative; Negative; Ne ative Recommendations: GENERAL - See Section VII VII. Recommendations The laboratory results of the potential ACM sampled at 2335 Bald Mtn Rd, Unit 15, Vail, Colorado, indicate that all bulk-samples of drywall and cloth wall covering analyzed were reported as negative for asbestos. Therefore, no professional abatement activities are recommended to remove the above- referenced material. G STATE OF COLORADO ASBES"['OS CERTIF(C;1T101'� ( �,IuraJn Ur��artrnrrl ��C P��hli� I lrallii :in�i En�irunnirri \�r P��IIuU��r, !. ���nUUI I h� ;.�i,n Steve Shurtliff ( crtilicutiun \u: I�-tll L:�< mii th� rr��uu�cnuu;, u!''_ - -�u-. � �.R.�. :u�il -Air � �ualin �'nntrul i umrni•.i��n R�•e��l'at�un \�,. ti. P:�rt li.:iu�l i. hnirh� :rr;ilir�l b� ih: �l:tir nl�( �ul�,f�tl<� in lhr !i�l��nt in,� �,i,:i�iltni � l3uildin}; Inspector^' Is.ucd: n� I 2:�?II I II h\pires nn: 6� 122011 rv,;, , ,,. �, �od,,,,n „r��d„���,�,,,,��,,,.��„�,,,,,,��n,,,,��„-�y,�.,,.,.��,.,,,�,.. .�,,,, ..r��� �n.,n �n ilr,-di,�y�lrrr .����� rli,�.f:�h„„ � _` i •u�vv�v�vy� v •vv��� ��v�.� � --,�—` ASSOCIATES, INCORPORATED `` CONSULIING LABORATORY Certificate of Analysis i�yyy w. �,vuaxr+ve Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloav.net ClientName iri (��m�uliin�>_ In� ������• DateCoilected: 08/02/10 Street address ����n I I:�u,�c6 (�i ��� Date Received: 08/03/10 City, StateZlP �1��rr;���n. C��> �n�i��� Date Analyzed: 08/10/10 Attn; �n � r'�! � �� rt I i� 1 #200860-0 Date Reported: 08/10/I O ClientProjectName: '�?� fi:�IJ �1u�. R�L ����iL (��� � nii I� ProjectID: 105361 Job ID: Test Requested: 30(12, Asbestos io Bulk Samples Method: Polazized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-As stos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam e Number Additional Comments es/no La ers % area % area % com sition 10% 105361-1A White/Tan Drywalt N 4,25% Negative CELL 90 105361-1B White Compound w/ White Paint N 4,25% Negative 100 C DW01-01 98% 105361-1C White Tape N 4,25% Negative CELL 2 105361-1D White Joint Compound N 4,25% Negative 100 C 105361-2A Brown Resinous Material N 5,1% Negative 100 B 10% 105362-2B White/Tan Drywall N 5,14% Negative CELL 90 98% DW01-02 105361-2C White Tape N 5,20% Negative CELL 2 105361-2D White Compound w/ White Paint N 5,20% Negative 100 C 105361-2E White Joint Compound N 5,45% Negative 100 C DWO1-03 105361-3 NO SAMPLE IN BAG / ,/ ' , / /� /., � . � , i' , , . i e c sum ce e Laboratory Analyst am ump eys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY�hrysotile CR = Cmcidolite TR = Tremolite Trace=Less Than 1% CELL = Cellulose MW = Minetal Wool FBG = Fiberglass Sl'N = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Cazbonates V = Vermiculite G = Gypsum M = Mica T=Taz P = Perlite O = Organic B = Binder �,.M,..�.. , ..�.n,���...�.�..,,�.,�,. ,.x>M�,,�.,n,�...P,��.�,�»,�.,�,..� .�,�,.»�..,�.,,�.,�,n .�,. ,.,�...���„�.,u�,.��r�..,���.�,�•.��,..�.,�<W.�«,.�,.,.n,.��a,.M,�.�,.��,...�.�,em,.�,�;� _ ..�..,,.....��..,�...,,��....,�...,,.w..„,�.-.w,.., _` i •u�vv�vivy� v •vv��� •�v��' t �ASSOCIATES, INCORPORATED CONSULi1NG LABORATORY Certificate of Analysis i�yyy w. t,o�tax t�ve Suite 205 Lakewood, CO 80401 3032323746 www.aerobioloov.net Client Name I� �� ���� n, u I i � n:� . I n �� . �� �� �� Date Collected: 08/02/ 10 Streetaddress ������ I�L�u��cl. C�i � DateReceived: 08/03/10 City, State ZIP �I����ri���n. ��� i�tu�t,� Date Analyzed: 08/10/10 Attn: � i ���� i� u ri I i I 1 #200860-0 Date Reported: O8/ 10/10 ClientProjectName: _??� It��l�f �ti��. R�L ��;�iL ��t� i�nii i� ProjectID: 105361 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % area % area % com sition 98% 105361-4A White Tape N 4,20% Negative CELL 2 105361-4B White Comopund w/ White Paint N 4,20% Negative 100 C DW02-01 105361-4C White Joint Compound N 4,20% Negative 100 C 10% 105361-4D White/Tan Drywall N 4,40% Negative CELL 90 105361-SA White Joint Compound N 4,15% Negative 100 C 105361-SB White Comopund w/ White Paint N 4,20% Negative 100 C DW02-02 98% 105361-SC White Tape N 4,20% Negative CELL 2 10% 1OS361-SD White/Tan Drywall N 4,45% Negative CELL 90 105361-6A White Joint Compound N 3,30% Negative 100 C DW02-03 98% 105361-6B White Tape N 3,30% Negative CELL 2 /.. � / ��,�i� ��� � i . . � e c sum ce e Laboratory Analyst am ump eys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trace=Less Than 1 % CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiforrn TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T=Tar P = Perlite O = Orgac�ic B = Binder __ i •�.��vv�va.v�' v �vv�v •�v��r t �ASSOCIATES, INCORPORATED CONSULIING LABONATORY Certi�cate of Analysis i �yyy w. wuux nve Suite 205 Lakewood, CO 80401 3032323746 www.aerobioloav.net CiientName ���� (���n����t��,:�_ !nc- M����� DateCollected: 08/02/10 Street address ��t,a I luir��rl. � i �N � Date Received: 08/03/10 City, StateZIP �1��rr��t�n. ��u �n�l��� DateAnalyzed: 08/10/10 Attn: �tr�c �Ii�uti:i�i� #200860-0 DateReported: 08/10/10 ClieotProjectName: '?�� I;,�l�l �1i�,. K�I �:�ii ��t�i nii 1�� ProjectID: 105361 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polazized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Mater'rals. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material lient La Sam le Number Additional Comments es/no La ers % area % area % com sition DW02-03 105361-6C White Compound w/ White Paint N 3,40% Negative 100 C 98% 105361-7A Tan Fibrous Material N 3,2% Negative CELL 2 MISC01-01 105361-7B Yellow Mastic N 3,13% Negative 100 B 80% 105361-7C White Fibrous Woven Resinous Material N 3,85% Negative CELL 20 � � / ! j� ! i` / /� , i e c aum ce e Laboratory Analyst am ump reys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trace=Less Than 1% CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibmus Talc AH = Animal Hair Q = Quartz C = Cazbonates V = Vermiculite G = Gypsum M = Mica T=Tar P = Perlite O = Organic B = Binder ....,..., . _.-...... � �.,,. � .. .. . , .. ,,. T ,.,m��,m.,. �„� ,� , ,, .,��„ �.�,,��, � ....,�.�m �. �..TMMZ„�,. ,.�,����,�.�...�,...�„��.�.�.�.�,��..��,.,.,..,.�,m,,p.�,.w.A,..,� re.� , . �, w - . R � . � _ ....��..�.�..m. � AERObIO�OCiy LAbORATORy �ASSOCIATES, INCORPORATED CONSULTIVG L+�F30RAIORY Certificate of Analysis 13949 W. Colfa�c Ave Suite 205 �eW�a, co soao� 303.2323746 www.aerobio�opv.net I �ti t���n,ulun�.� In: 5366 Flatrock Ct. Morrison, CO 80465 Steve Shurtliff Client Project Name: �_;�;� !�:�1;1 �itn I:�I \;i�L� ! �l nit 1� a�a�a�. #200860-0 Date Collected: 08/02/10 Date Received: 08/03/10 Date Analyzed: 08/10/1 � Date Reported: 08/10/10 Project ID: 105361 Job ID: Genernl Notes ♦ Negative indicates no asbestos was detected; the method detection limit is 1%. ♦ Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than the method detection limit of 1%. ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, Vemolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variery of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the asbestifortn variety of the mineral reibekite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under ffie NESHAPS regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted ♦ Unless notified in writing to retum the samples covered by this report, Aerobioiogy Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling chazge will be assessed for the return of any samples. Notes Reauired bv NVLAP ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Govemment. ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP-approved signatoty. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 D10-0008 : Entries for Item:90 - BLDG-Final 11:16 01/15/2013 Action Comments By Date Unique_ Ke AP sgremmer 08/23/2011 A000144 495 Total Rows: 1 Page 1