HomeMy WebLinkAboutA10-0085TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970 - 479 -2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT
OWNER
APPLICANT
CONTRACTOR
Job Address: 433 GORE CREEK DR VAIL
Location.....: UNIT 16B, VAIL TRAILS EAST
Parcel No...: 210108234024
Project No
BRUECKER WOOD REAL ESTATE TR 10/14/2010
330 OLD Y RD
GOLDEN
CO 80401
THUL ELECTRONIC
P 0 BOX 534
AVON
CO 81620
License: 112 -S
THUL ELECTRONIC
P 0 BOX 534
AVON
CO 81620
License: 112 -S
SYSTEMS 10/14/2010
SYSTEMS 10/14/2010
Permit #: A 10 -0085
Status ...:
ISSUED
Applied..:
10/14/2010
Issued . ..
10/14/2010
Expires . .:
04/12/2011
Phone: 970 - 949 -4638
Phone: 970 - 949 -4638
Desciption: NEW FIRE ALARM SYSTEM FOR RESIDENTIAL UNIT REMODEL
Valuation: $2,100.00
**** f#***#### k* k**###*###*}**}#**###* # # # # * * } * * *f } * } * } * # # * # * # }f } * * } *# FEE SUMMARY *#*##* k*}**}}#* f*#####}***#** # } # * * # * # # #f # * * } * } }k * * f # * * * * # * ##
Electrical - - - - -> $0 .00 Total Calculated Fees - -> $366.75
DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00
Investigation - - -> $0.00 Total Permit Fee -- ----- > $366.75
Will Call --------- > $0.00 Payments ------ -- ----- - -> $366.75
TOTAL FEES - -> $366.75 BALANCE DUE--- - - - - -> $0.00
Approvals:
Item: 05600 FIRE DEPARTMENT
10/14/2010 mvaughan Action: AP
CONDITIONS OF APPROVAL
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN AD3�ANPF,0 TELEPHONE AT 979479 -2252 FROM 8:00 AM - 5 PM.
GNATURE OF OWNER OR CONTRACTOR HIMSELF AND OWNER
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: R100001576 Amount: $366.75 10/14/201003:12 PM
Payment Method: Check Init: SAB
Notation: 17423 -THUL
ELECTRONICS
-----------------------------------------------------------------------------
Permit No: A10 -0085 Type: ALARM PERMIT
Parcel No: 2101 - 082 - 3402 -4
Site Address: 433 GORE CREEK DR VAIL
Location: UNIT 16B, VAIL TRAILS EAST
Total Fees: $366.75
This Payment: $366.75 Total ALL Pmts: $366.75
Balance: $0.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
BP 00100003111100 FIRE ALARM PERMIT FEES 78.75
PF 00100003112300 PLAN CHECK FEES 288.00
----------------------------------------------------------------------- - - - - --
Department of Community Development
75 South Frontage Road
Vail, Colorado 81657
Tel: 970 - 479 -2128
Fax: 970 - 479 -2452
Web: www.vailgov.com
evelopmen , j, ,. rd'
FIRE ALARM PERMIT
Commercial and Residential Fire Alarm shop drawings are required at the time of application
submittal and must included information listed on the 2nd page of this form. Application will
not be accepted without this information.
Project Street Address:
433 Gore Creek Drive
(Number) (Street)
Building /Complex Name: Vail Trails East
Contractor Information:
Company: Thul Electronics
Company Address: PO Box 534
City: Avon State: CO
Contact Name: Ron Davidson
16B
(Suite #)
Zip: 81620
Contact Phone: 970.949.4638
E -Mail ron @thulelectronics.com
Town of Vail Contractor Registration No.: 112 -S
D'yaany M (*b.'.' 'h.-'
Deborah Shaner o F E.email= hamrls@co n t,c
X ry
D 2010.10.1318:21:13 -060P
Contractor Signature (required)
Property Information
Parcel #: 2101- 082 -34 -024
(For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or
visit www.eaglecounty.us /patie)
Tenant Name:
Owner Name: BRUECKER WOOD REAL ESTATE TRUST
Complete Valuation for Fire Alarm Permit:
Fire Alarm $: $2100
I'V 7
Office Use:
Project #: JO R1 I 0 OV 11
Building Permit #: BID ' l a5
Alarm Permit #: /'T i o `" c 3 s
Lot #: Block # Subdivision:
Detailed Description of Work: New fire alarm system
for residential unit.
(use additional sheet if necessary)
Does a Fire Alarm Exist? Yes ( ) No (� )
Does a Sprinkler System Exist? Yes ( ) No ( )
Work Class:
New ( ) Addition ( ) Remodel ( .,) Repair ( )
Retro -Fit ( ) Other ( )
Type of Building:
Single - Family ( ) Duplex ( ) Multi - Family (� )
Commercial ( ) Restaurant ( ) Other ( )
Date Received: L
D
Ul t 14 2010
TOWN OF VAIL
29- May -09
I Honeywell
VISTA -21 iP
CONTROL PANEL I
Ins
Honeywell's high capacity, feature -rich VISTA -21 iP lets you
deliver more value to your customers on each and every
sale. The VISTA -21 iP provides up to 48 zones of protection,
an on -board IP connection, graphic keypad support and
dual partitions. The VISTA -21 iP gives you the ability to send
alarm signals and upload /download via an Internet Protocol
(IP), improving the speed at which information can be delivered
FEATURES
to and from the control panel. When used with an optional
AlarmNet GSM that snaps right on the board, the VISTA -21 iP
can be installed in premises without TELCO lines - guaranteeing
communication independent of any infrastructure. The panel's
installation advantages, innovative end -user benefits and
robust system capacity make the value - priced VISTA -21 iP
an ideal choice for higher -end installations.
• Internet alarm reporting and
uploading /downloading capability
via on -board AlarmNet Internet
Communicator
• Supports four graphic
touchscreen keypads
• Wireless keys can be programmed
without using zones
• Eight on -board hardwired zones
standard (15 when Zone Doubling
feature is used)
- 40 hardwired expansion zones
- 40 wireless expansion zones
• Two low current on -board
trigger outputs
• 100 Event Log viewable at system
keypads with time /date stamp
• 48 system user codes assignable
to either partition
• Expandable to 48 total zones when
used with hardwired and /or wireless
expansion modules
• Two independent partitions plus a
common partition
- Global arming from any
system keypad
- Goto function to view or operate
one partition from the other
- Separate partition account numbers
• 16 output devices
- Relays (Model 4204 Relay Modules,
or 4229 Expansion Module), and /or
X -10 devices (when used with a
4300 Transformer)
• Four installer - configurable zone
types allows the installer to create
custom zone types by assigning
all zone attributes
• Supports four -wire, and up to
16 two -wire smokes
- Works with Sentrol CleanMeTM
maintenance signal
• Multiple actions on output devices
depending on system state
- Turns lights off when system arms
- Turns the same light on
when system disarms
- Flashes same lights when system
is in alarm
• Built -in phone line cut monitor
with programmable delay and
annunciation options
- Display on system keypads
- Trigger local sounders
- Trigger system bell
Security Dealer Features
• Automatic System Load Shed
- During extended AC power fail,
the system battery will be
disconnected to prevent irreversible
battery failure. Reduces service
calls to replace batteries.
• Dynamic Signaling
- Reduces redundant reporting to
the central station when multiple
reporting methods are used;
i.e. digital dialer and AlarmNet radio
Valuable End -User Features
• Viewable on system keypads:
- Exit countdown
- Time and date display'
- Event log'
• Auto keypad backlighting on entry
• Keyswitch arming
• Programmable macro buttons and
single -button arming
• Supports a variety of wireless remote
controls for single- button operation
• User Scheduling
- Automatically activates X -10 and
relays at programmed times
- Latchkey reports to pagers
- Auto arm /disarm
- "User access" time windows
• Supports up to four end -user
numeric pagers
• VIP Module allows system control
from any touchtone phone
• Chime by zone
`Requires custom alpha keypad
VISTA -21 W
CONTROL PANEL
SPECIFICATIONS
Electrical
• Aux. power 12VDC, 600mA maximum
• Seven hour standby at 400mA aux.
load with four amp hour battery
• 16.5VAC /40VA transformer
• Alarm output 12VDC, 2.0 amps max.
- For agency listed installations,
combined aux. and alarm output
cannot exceed 700mA
Output Control
• Supports up to four relay boards
(up to 16 relays)
• Optional X -10 transformer /interface
(part no. 4300) may be used to control
up to 16 X -10 receiving devices
Zones
• Eight hardwired zones
(15 with zone doubling)
• Selectable response 10msec,
350msec, 750msec
• Assignable to any partition
• 20 selectable zone types plus four
configurable zone types
• Programmable swinger suppression
Expansion Devices
• 4219 - Eight hardwired zones - 16mA
• 4204 - Up to four relays - 15mA
standby (each active relay
draws an additional 40mA)
• 4229 - Eight hardwired zones and two
relays - 36mA (each active relay
draws an additional 40mA)
Accessories
• VISTA -GSM Snap -in Dual -Path Digital
Wireless Communicator (IP required
for activation and registration)
• 4286 VIP Voice Module - 220mA
• 5881 ENL RF Receiver supports
up to eight zones - 60mA
• 5881 ENM supports up to
16 zones - 50mA
• 5881 ENH up to 48 zones - 50mA
• 5883H High Security Transceiver
Module supports up to 48 zones -
80mA
• Supports Eagle 1225 and 1221 boards
Keypads
• 6160 Custom Alpha
(required for programming)
- 100mA
• 6160V Custom Alpha Voice
- 100mA
• 6150 Fixed English LCD
- 85mA/40mA
• 6150V Fixed English Voice LCD
- 85mA/40mA
• 615ORF Fixed English RF LCD
- 85mA/40mA
• 6148 Fixed English LCD
- 70mA/3OmA
• 6270 Graphic Touchscreen
User Interface
• 6271 C Color Graphic Touchscreen
User Interface
• 6271 CV Color Graphic Touchscreen
User Interface with Voice
• 8132 Symphony Advanced User
Interface
Agency Listings
ETL listing
• Residential Fire and Burglary:
- Household Fire Warning System
Units - ANSI/UL 985, 2000/05/26
(5th edition) with revisions up to
2004/04/29
- Standard for Safety for Digital Alarm
Communicator System Units -
ANSI /UL 1635, 1996 (3rd edition)
- Safety of Household Burglar Alarm
System Units, ANSI /UL 1023, issued
1996/11/25 (6th edition) with revisions
up to 12/30/04
• Commercial Burglary:
- Standard for Safety for Police Station
Connected Burglar Alarm Units and
Systems - ANSI/UL 365 (4th edition),
issued 1997/01/31 with revisions up
to 2005/03/08
- Standard for Safety Local Burglar
Alarm Units and Systems - UL 609
(11th edition), issued1996 /08/28 with
revisions up to 2005/03/17
- Standard for Safety Central Station
Burglar Alarm Units - ANSI /UL 1610
(3rd edition), issued 1998/10/26 with
revisions up to 2005/08/16
Communications
• VISTA -GSM Snap -in Dual -Path Digital
Wireless Communicator (IP required
for activation and registration)
• Touchtone or pulse standard TELCO
dialers
• Formats supported
- ADEMCO Contact ID
- ADEMCO 4 + 2 Express
- ADEMCO low speed
- Sescoa/Radionics
• 3 + 1, 4 + 1 and 4 + 2 reporting
• Reporting capabilities
- Split
- Dual
- Split/Dual - True dial tone detection
• Low battery reports 11.2 - 11.6VDC
• AC loss and restoral reporting supported
ORDERING
VISTA -21 iP Control Panel
VISTA -21 iPSIA Control Panel for SIA Installations
VISTA -GSM Optional Snap -in Radio Module
VISTA -ULKT Cabinet for Listed Commercial Burglary Applications
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747 arch 0 0
March 9
M 2009
www.honeywell.com 0 2009 Honeywell International Inc.
Honeywell
Honeywell
5192S D/5192S DT
V -PLEX® SMOKE DETECTOR
The Honeywell 5192 Series low profile, addressable V -Plex
smoke detectors deliver state -of- the -art features and
benefits in a cost - effective package. These detectors are
designed to provide open area coverage and are
compatible with Honeywell's VISTA controls supporting
V -Plex technology.
An LED on the detector will blink periodically during normal
conditions, remain on steady during alarm and cease to
pulse if the chamber is out of acceptable sensitivity range.
An extremely powerful feature available within the 5192
Series is the Automatic Maintenance Alert/Reporting
capability — a feature normally found in today's high end
analog addressable systems. The detectors continually
monitor their own sensitivity levels in addition to the basic
normal and alarm conditions. These HIGH and LOW
SENSITIVITY signals are communicated back to the
FEATURES
control, via the V -Plex addressable loop, to indicate locally
and at the central station that the detector may not be able
to detect smoke or may false alarm. This feature works
with VISTA -32FB, 12813P, 128FBP, 25013P, 250FBP, 40,
50P, 100 -24 and FAP FA1600C, FA1660C and FA1700C.
More important is the cost saving associated with
Automatic Maintenance Reporting. The feature is an
approved alternate to NFPA 72 field sensitivity calibration
testing that require external test meters. This eliminates the
need to schedule inspections to determine detector
sensitivity/viability. Another important benefit of these V -Plex
(addressable) smoke detectors is their ability to operate on
existing wiring.
There is no need to run special twisted pair, data grade or
shielded wires, providing you with the right choice for all
your retrofit applications. That equates to cost savings in
time and materials!
• Low profile design
• Available with integral heat sensor
• Lines on existing or
conventional wiring
• V -Plex addressable loop device
• Automatic maintenance reporting
APPLICATIONS
• Simple 2 wire installation
• DIP switch or serial number
programmable
The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection
applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V -Plex
addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications. They are
suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or
professional office suites and in factory and warehouse environments.
5192SD/5192SDT
V- PLEXT"^ SMOKE DETECTOR
SPECIFICATIONS
Installation
The 5192 Series smoke detectors are
supplied with a convenient mounting
bracket that allows the detector to
be mounted to a variety of electrical
junction boxes. A removable terminal
block, that accepts 14 to 22 gauge wire
to provide easy wiring connections. The
detectors are designed to meet
all applicable requirements for UL
Commercial and Residential Fire
installations as well as NFPA 72
requirements when installed in
compliance with the National
Electric Code and approved listed control
panels.
_it
W
o z Q -
W a
J
J 2
D�
«
m0
- -
W (�
LUW
0)
DIP
m
F Q
SWITCH REMOVABLE
y d
TERMINAL BLOCK
>f
0
diagram for 5192SO/SDT smoke detector
Wiring
Compatibility
Serial number addressing is supported on
VISTA -32FB, 12813P, 128FBP, 25013P,
250FBP, 100 -24 and FAP FA1600C,
FA1660C and FA1700C controls. (Refer to
control panel and smoke detector
installation instructions for details.)
Automatic Maintenance
Reporting Compatibility
The automatic maintenance feature is
compatible with the following control
panels:
- VISTA -32FB
- VISTA -128BP
- VISTA- 128FBP
- VISTA -250BP
- VISTA- 250FBP
- FA1600C
- FA1660C
- FA1700C
The automatic maintenance may be
disabled for all other controls that
do not support this feature. Refer
to control panel and smoke detector
Installation Instructions for details.
Electrical:
Mechanical:
• Diameter: 5.5 inches (140mm) (including
mounting bracket)
• Height: 1.7 inches (43mm)
(including mounting bracket)
• Weight: 5.3 ounces (150 grams)
Environmental:
• Installation temperature range:
32° to 100 °F (0° to 38 °C)
• Installation humidity range:
10% to 93% RH, non - condensing
• Heat sensor (5192SDT only):
135oF fixed temperature
electronic thermistor
• EMI: Meets or exceeds the
following requirements:
- FCC Part 15, Class B Device
- IEC EMC Directive
Agency Listings
• UL268 Commercial System
Smoke Detector
These smoke detectors are compatible
with all VISTA control panels that support
V -Plex (addressable) polling
loop technology. The detectors support
DIP switch or serial number addressing.
DIP switch configuration are compatible
with 5140XM, VISTA -40, and
VISTA -50P controls.
ORDERING
• System voltage range: 7 -14 V
Standby current (maximum @ 12V):
- LED off: 1.2mA
- LED on: 2.8mA
• Meets UL 217 Requirements
for Residential
5192SD Addressable Photoelectric Smoke Detector
5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor
For more information: www.honeywell.com /security /hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
Melville, NY 11747
1.800.467.5875 vet 200
ell.com May zoos
www.honey 0 2009 Honeywell International Inc.
Honeywell
6160 -- -
ALPHA DISPLAY KEYPAD !`
REP(
WITH DOOR ATTACHED -- t e ' 2 _ 3 �' ^+
WITHOUT DOOR
The 6160 Deluxe Keypad is easy to install and simple to
use. The attractive white console blends with any decor and
features a contoured, removable door that conceals
illuminated soft -touch keys. The 6160 also features a new
larger and brighter 32- character display with easy -to -read
plain - English status messages.
FEATURES
The oversized function keys are easily accessed even when
the keypad door is closed, and can be programmed for fire,
burglary, personal emergencies and other operations. Colored
self- adhesive labels are included.
• Large, easy -to -use keypad
• Keys continuously backlit for greater
visibility
• Speaker with audible beeps
to indicate:
- System status
- Entry/exit delay
- Other alarm situations
SPECIFICATIONS
Physical
• 5- 5/16 "H x 7 -3/8 "W x 1- 3/16 "D
(135mm x 190mm x 30mm)
Current
• Standby -40mA
• Activated Transmission -160mA
• Zones and system events displayed
in plain English
• No confusing blinking lights
• Four programmable function keys
Wiring
• - (Black):
Ground
• + (Red):
+12 VDC (Aux. Power)
• D1 (Green):
"Data in" to control panel
• DO (Yellow):
"Data out' from
control panel
ORDERING
6160 Alpha Display Keypad
Honeywell Security & Custom Electronics
Honeywell International Inc.
PO Box 9035
Syosset, NY 11791
www.honeywell.com
C0060
V6160 /D
September 2006
0 2006 Honeywell International Inc.
• System functions clearly labeled
• Functions performed by just entering
security code plus command
• White with removable door blends
with any decor
Compatibility
• Fully compatible with all
VISTA controls.
Honeywell
SYSTEM
SENSOR"
Mini -Horns
The SpectrAlert'Advance series of mini-horn sounders
are designed to simplify installations to provide
primary and secondary signaling for fire and security
applications.
7 S s Y e S e
Features
12 and 24V operation
• High and low volume settings
• Temporal and non - temporal tones
Mounts to single gang back box
Compatible with MDL sync module
Mechanically and electrically compatible with PA400 series
Mini - Alert" sounders
Agency
Listings
&
FM MEA
LISTED
APPROVED approved "
The MHR and MHW mini -horns operate at 12 and 24 volts and are
ideal for hotel, motel or residential fire system applications, where
a smaller notification device is desired. The mini -horns offer high
and low volume settings, and temporal or non - temporal tones. The
horns can be mounted to single gang back boxes for aesthetically
sensitive applications. Synchronization is also provided when using
the MDL module.
The MHR and MHW mini -horns can operate between 32 and 120
degrees Fahrenheit from a regulated DC or full -wave rectified,
unfiltered power supply. They are listed to Underwriter's Laboratories
Standard UL 464 for fire protective signaling systems.
SpectrAlert" Advance Mini -Horn Specifications
Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini -
horn shall be listed to Underwriter's Laboratories Standard UL.464 for fire protective signaling systems. Mini -horns shall operate between 32 and 120 degrees
Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync - Circuit Module, 12 -volt rated notification appliance
Circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.
Physical Specifications
Dimensions 4.61 x 2.9W x .45
Weight 2.67 oz.
Operating Temperature Range 32 "F to120°F(0 °C to 49 °C)
Mounting Surface: single -gang back box
Flush: 4 x 4 deep back box (2
Electrical Specifications
Input Terminals 12 to 18 AWG
Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR
Operating Voltage 8 -33
Operating Voltage with MDL 9 -33
UL Sound Output and Current Draw Data
Switch Setting
Pattern Output Level
8 -17.5 VDC
8 -17.5 VFWR
Nominal 12 VDC
Nominal 12 VFWR
16-33 VDC
16 -33 VFWR
1
Temporal High
68
67
71
70
78
76
2
Temporal Low
66
65
69
68
76
75
3
Non - temporal High
72
71
75
74
80
79
4
Sounder Current
Non- temporal Low
Draw (mA RMS)
70
69
73
72
78
77
Switch Position
Sound Pattern Volume
8 -17.5 Volts
DC
FWR
16 -33 Volts
DC
FWR
1 Temporal High 12 10 17 15
2 Temporal Low 10 9 14 13
3 Non - temporal High 22 17 29 25
4 Non - temporal Low 17 13 21 19
Ordering Information
MHR Mini -Horn, Red
MHW Mini -Horn, White
030075Yv—Sem—
SYSTEM
3825 Ohio Avenue - St. Charles, IL 60174 Produc«,t— wa"„ oc— MWSYM —n—for
SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 `— product t W—rflon, "lud'"g`*1awv"N""°rd'd`M'a`h�
Aos -0414 - 000.1107.11743
$
c
0
�
�
�
�
c
0
I ra
m
m
N
C
�
�
$
3
13
0
�
■
u
2
�
c
V
■
N
2
.§
(A
2
N
�
�
�
o
\
�- §§
E/
•>
��
c
5�
_�
ƒ
(
\
V)3
E
E
° @
�2
=
I
�&
_
�k
\
j
§
{u
\7
(D
5
E�
/\
e
°
8
) §
/2
\±
o£
=
2
®
�
m
:3
//
2
/
u
§
] \
/\
f
W
\}
E
\
k
§
i
\ 7
r
=_
E
_
2 _
2
e
CL®
m e
/E
CD
2
«—
/
§ /
0 -
:
2
/ \
o
/
/
§
2
■
s
'
E -
q:
2
{
E �
q
/
\
/ $
® E
§k
(/
\
kk
%
« §
=
k
{$
f/f
$t
k\
k(
/
i.
7
w
=
o
§!
Vo
§
V ) —
0
N
��
\ u
E 0=
•k>
uo
® c
��
�c ;
�V�
a'
&2 = .0
2
>
<
._x_
«$\
k/
/
kcE
Lm
o /(\
CL
2 /\
Zuozƒ
m
0
��
�of�.
g7
a
�
3
«(n ua
3
m,2
L.
f
i
Vi a) o
�j7��
�
L.
c
2=
/
��2�
§:0
5
=me
c
=c
c
o
4
2
»
Q
w
0
oo
=
a)
0
7
:»
'C
L) U
w
a-i
Ue -j Li-
U. !!::a
CO
m
N
R
fD
Z
J 0 rn
N
= W N 00
y
C
Mv)
v
V
�
v
d
N
S
a
E
Lm
a
a
W
.a
O
E
V
N_
a
CL
` L
i
M
o
0
y
c
W
��
H
C
C
y
O V
E
i
s
V
0
M
u
T—
U° Q
cr
4)
RT
•
CO
m
N
R
fD
Z
SYSTEM
SENSOR"
5600 Series Mechanical
Heat Detectors
System Sensor's 5600 series mechanical heat detectors
offer a low -cost means for property protection against
fire, and for non -life- safety installations where smoke
detectors are inappropriate.
Features
Multiple configurations for installations:
- Single- and dual- circuit models
- Fixed temp and combination fixed- temp /rate -of -rise
1357 or 1947 ratings.
Plain housing for residential installations (Model 5601 P)
Easy -to -use terminal screws
A broad range of back box mounting options:
- Single gang
- 3.5 and 4 Octagonal
-4 "square with square to round plaster ring
• Reversible mounting bracket
Agency Listings
@ <FM > MEA
LISTED APPROVE, approved
Multiple configurations. The 5600 series offers a full -line of
configurations to accommodate a broad range of applications. Both
single- and dual- circuit models are available for low- and high -
temperature ratings with either fixed temperature or combination
fixed temperature /rate -of -rise (ROR) activation. The ROR element of
the fixed /ROR models is restorable to accommodate field- testing.
Installation flexibility. To satisfy a variety of installation needs,
the 5600 series easily mounts to single -gang and octagonal back
boxes. And these models accommodate four- square back boxes,
when used with a square to round plaster ring.The reversible
mounting bracket permits both Flush- and surface -mount back box
installations.
Visual identification. The 5600 series provides clear markings on
the exterior of the unit to ensure that the proper detector is being
used. Alphanumeric characters identify the activation method, as
well as the temperature rating, in Fahrenheit and Celsius degrees.
Fixed temperature models are identified FX, while combination
fixed /rate -of -rise units are marked FX /ROR.The 5600 series also
provides a post- activation indicator in the form of a collector. When
the detector is activated, the collector drops from the unit, making it
easy to identify the unit in alarm.
Specifications
Arch itectu ral/Engi nee ring Specifications
Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire
Protective Signaling Systems.The detector shall be either a single- circuit or a dual- circuit type, normally open. The detector shall be rated for activation at either
135 "F (57'C) or 194 °F (90 °C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature /rate -of -rise thermal sensor.
The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15 °F (8.3 °C) per minute. The detector shall include a reversible mounting
bracket for mounting to 3 -inch and 4 -inch octagonal, single gang, and 4 -inch square back boxes with a square to round plaster ring. Wiring connections shall
be made by means of SEMS screws that shall accommodate 14 -22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing
to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature /rate -of -rise models shall be restorable, to
allow for field- testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm.
Physical/
Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100 °F (38 °C)
5602, 5604, 5622, and 5624:150'F (65.6 °C)
Operating Humidity Range 5 to 95% RH non - condensing
Dimensions with mounting bracket Diameter: 4.57 inches (I 1.6cm)
Height: 1.69 inches (4.3cm)
Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57 °C)
5602, 5604, 5622, and 5624:194 °F (90 °C)
Weight 6 oz. (170 grams)
Rate -of -Rise Threshold 15 °F (8.3 °C) rise per minute (models 5601 P, 5602,562 1, and 5622 only)
Mounting 3 -inch octagonal back box
4 -inch octagonal back box
Single gang back box
4 -inch square back box with a square to round plaster ring
Electrical Specifications
Operating Voltage /Contact Ratings 6- 125VAC / 3A
6 -28VDC / 1 A
125VDC / 03A
250VDC / 0.1 A
Input Terminals 14 -22 AWG
No
IN
e
lJ
X1
C,
5601P 5602,5622 5603,5623 5604,5624 5621
5
S ingl e L e tte ring
194 °F ( °C)
Fix Temp / Rate -of -Ri
5 0 f x 50 f eet ( 1 5.2 4m x 15.2m)
5603
Single Lettering
135 °F (57 °C)
F i x ed T emperatu r e
25 feet x 25 feet (7.62m x 7.62m)
5604
Single Lettering
194 °F (90 °C)
Fixed Temperature
25 feet x 25 feet (7.62m x 7.62m)
5621
Dual Lettering
135 ° F (57 °C)
Fixed Temperature / Rate - of - Rise
50 feet x 50 feet (15.24m x 15.2m)
5622
Dual Lettering
194 °F (90 °C)
Fixed Temperature / Rate -of -Rise
50 feet x 50 feet (15.24m x 15.2m)
5623
Dual Lettering
135 ° (57 °C)
Fixed T emperature
25 f eet x 25 fe ( x 7.
5624 Dual Lettering 194 °F (90 °C) Fixed Temperature
*NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet.
25 feet x 25 feet (7.62m x 7.62m)
f -
SYSTEM
SENSOR
3825 Ohio Avenue • St. Charles, IL 60174
Phone: 800- SENSOR2 • Fax: 630-377-6495
02006 sytem Sen.—
P,°a,�ts�,�ats,mj�toa,angewRh moce\49tsntr°u� : «�,,,ro,
"""'t r "A"`t'"r°""a#MMk1d"19 the IaWt°""` Offts'aMSheet.
A05 0351 -002• 11/06• 91676
5601 P Single None 135 °F (57 °C) Fixed Tem R -of -Rise 50 f eet x 50 f e e t ( 15.24m x 1 5.2 m)