HomeMy WebLinkAboutA10-0085TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT OWNER APPLICANT CONTRACTOR Job Address: 433 GORE CREEK DR VAIL Location.....: UNIT 16B, VAIL TRAILS EAST Parcel No...: 210108234024 Project No BRUECKER WOOD REAL ESTATE TR 10/14/2010 330 OLD Y RD GOLDEN CO 80401 THUL ELECTRONIC P 0 BOX 534 AVON CO 81620 License: 112 -S THUL ELECTRONIC P 0 BOX 534 AVON CO 81620 License: 112 -S SYSTEMS 10/14/2010 SYSTEMS 10/14/2010 Permit #: A 10 -0085 Status ...: ISSUED Applied..: 10/14/2010 Issued . .. 10/14/2010 Expires . .: 04/12/2011 Phone: 970 - 949 -4638 Phone: 970 - 949 -4638 Desciption: NEW FIRE ALARM SYSTEM FOR RESIDENTIAL UNIT REMODEL Valuation: $2,100.00 **** f#***#### k* k**###*###*}**}#**###* # # # # * * } * * *f } * } * } * # # * # * # }f } * * } *# FEE SUMMARY *#*##* k*}**}}#* f*#####}***#** # } # * * # * # # #f # * * } * } }k * * f # * * * * # * ## Electrical - - - - -> $0 .00 Total Calculated Fees - -> $366.75 DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00 Investigation - - -> $0.00 Total Permit Fee -- ----- > $366.75 Will Call --------- > $0.00 Payments ------ -- ----- - -> $366.75 TOTAL FEES - -> $366.75 BALANCE DUE--- - - - - -> $0.00 Approvals: Item: 05600 FIRE DEPARTMENT 10/14/2010 mvaughan Action: AP CONDITIONS OF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN AD3�ANPF,0 TELEPHONE AT 979479 -2252 FROM 8:00 AM - 5 PM. GNATURE OF OWNER OR CONTRACTOR HIMSELF AND OWNER ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001576 Amount: $366.75 10/14/201003:12 PM Payment Method: Check Init: SAB Notation: 17423 -THUL ELECTRONICS ----------------------------------------------------------------------------- Permit No: A10 -0085 Type: ALARM PERMIT Parcel No: 2101 - 082 - 3402 -4 Site Address: 433 GORE CREEK DR VAIL Location: UNIT 16B, VAIL TRAILS EAST Total Fees: $366.75 This Payment: $366.75 Total ALL Pmts: $366.75 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 FIRE ALARM PERMIT FEES 78.75 PF 00100003112300 PLAN CHECK FEES 288.00 ----------------------------------------------------------------------- - - - - -- Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 -2128 Fax: 970 - 479 -2452 Web: www.vailgov.com evelopmen , j, ,. rd' FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: 433 Gore Creek Drive (Number) (Street) Building /Complex Name: Vail Trails East Contractor Information: Company: Thul Electronics Company Address: PO Box 534 City: Avon State: CO Contact Name: Ron Davidson 16B (Suite #) Zip: 81620 Contact Phone: 970.949.4638 E -Mail ron @thulelectronics.com Town of Vail Contractor Registration No.: 112 -S D'yaany M (*b.'.' 'h.-' Deborah Shaner o F E.email= hamrls@co n t,c X ry D 2010.10.1318:21:13 -060P Contractor Signature (required) Property Information Parcel #: 2101- 082 -34 -024 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Owner Name: BRUECKER WOOD REAL ESTATE TRUST Complete Valuation for Fire Alarm Permit: Fire Alarm $: $2100 I'V 7 Office Use: Project #: JO R1 I 0 OV 11 Building Permit #: BID ' l a5 Alarm Permit #: /'T i o `" c 3 s Lot #: Block # Subdivision: Detailed Description of Work: New fire alarm system for residential unit. (use additional sheet if necessary) Does a Fire Alarm Exist? Yes ( ) No (� ) Does a Sprinkler System Exist? Yes ( ) No ( ) Work Class: New ( ) Addition ( ) Remodel ( .,) Repair ( ) Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family (� ) Commercial ( ) Restaurant ( ) Other ( ) Date Received: L D Ul t 14 2010 TOWN OF VAIL 29- May -09 I Honeywell VISTA -21 iP CONTROL PANEL I Ins Honeywell's high capacity, feature -rich VISTA -21 iP lets you deliver more value to your customers on each and every sale. The VISTA -21 iP provides up to 48 zones of protection, an on -board IP connection, graphic keypad support and dual partitions. The VISTA -21 iP gives you the ability to send alarm signals and upload /download via an Internet Protocol (IP), improving the speed at which information can be delivered FEATURES to and from the control panel. When used with an optional AlarmNet GSM that snaps right on the board, the VISTA -21 iP can be installed in premises without TELCO lines - guaranteeing communication independent of any infrastructure. The panel's installation advantages, innovative end -user benefits and robust system capacity make the value - priced VISTA -21 iP an ideal choice for higher -end installations. • Internet alarm reporting and uploading /downloading capability via on -board AlarmNet Internet Communicator • Supports four graphic touchscreen keypads • Wireless keys can be programmed without using zones • Eight on -board hardwired zones standard (15 when Zone Doubling feature is used) - 40 hardwired expansion zones - 40 wireless expansion zones • Two low current on -board trigger outputs • 100 Event Log viewable at system keypads with time /date stamp • 48 system user codes assignable to either partition • Expandable to 48 total zones when used with hardwired and /or wireless expansion modules • Two independent partitions plus a common partition - Global arming from any system keypad - Goto function to view or operate one partition from the other - Separate partition account numbers • 16 output devices - Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and /or X -10 devices (when used with a 4300 Transformer) • Four installer - configurable zone types allows the installer to create custom zone types by assigning all zone attributes • Supports four -wire, and up to 16 two -wire smokes - Works with Sentrol CleanMeTM maintenance signal • Multiple actions on output devices depending on system state - Turns lights off when system arms - Turns the same light on when system disarms - Flashes same lights when system is in alarm • Built -in phone line cut monitor with programmable delay and annunciation options - Display on system keypads - Trigger local sounders - Trigger system bell Security Dealer Features • Automatic System Load Shed - During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries. • Dynamic Signaling - Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio Valuable End -User Features • Viewable on system keypads: - Exit countdown - Time and date display' - Event log' • Auto keypad backlighting on entry • Keyswitch arming • Programmable macro buttons and single -button arming • Supports a variety of wireless remote controls for single- button operation • User Scheduling - Automatically activates X -10 and relays at programmed times - Latchkey reports to pagers - Auto arm /disarm - "User access" time windows • Supports up to four end -user numeric pagers • VIP Module allows system control from any touchtone phone • Chime by zone `Requires custom alpha keypad VISTA -21 W CONTROL PANEL SPECIFICATIONS Electrical • Aux. power 12VDC, 600mA maximum • Seven hour standby at 400mA aux. load with four amp hour battery • 16.5VAC /40VA transformer • Alarm output 12VDC, 2.0 amps max. - For agency listed installations, combined aux. and alarm output cannot exceed 700mA Output Control • Supports up to four relay boards (up to 16 relays) • Optional X -10 transformer /interface (part no. 4300) may be used to control up to 16 X -10 receiving devices Zones • Eight hardwired zones (15 with zone doubling) • Selectable response 10msec, 350msec, 750msec • Assignable to any partition • 20 selectable zone types plus four configurable zone types • Programmable swinger suppression Expansion Devices • 4219 - Eight hardwired zones - 16mA • 4204 - Up to four relays - 15mA standby (each active relay draws an additional 40mA) • 4229 - Eight hardwired zones and two relays - 36mA (each active relay draws an additional 40mA) Accessories • VISTA -GSM Snap -in Dual -Path Digital Wireless Communicator (IP required for activation and registration) • 4286 VIP Voice Module - 220mA • 5881 ENL RF Receiver supports up to eight zones - 60mA • 5881 ENM supports up to 16 zones - 50mA • 5881 ENH up to 48 zones - 50mA • 5883H High Security Transceiver Module supports up to 48 zones - 80mA • Supports Eagle 1225 and 1221 boards Keypads • 6160 Custom Alpha (required for programming) - 100mA • 6160V Custom Alpha Voice - 100mA • 6150 Fixed English LCD - 85mA/40mA • 6150V Fixed English Voice LCD - 85mA/40mA • 615ORF Fixed English RF LCD - 85mA/40mA • 6148 Fixed English LCD - 70mA/3OmA • 6270 Graphic Touchscreen User Interface • 6271 C Color Graphic Touchscreen User Interface • 6271 CV Color Graphic Touchscreen User Interface with Voice • 8132 Symphony Advanced User Interface Agency Listings ETL listing • Residential Fire and Burglary: - Household Fire Warning System Units - ANSI/UL 985, 2000/05/26 (5th edition) with revisions up to 2004/04/29 - Standard for Safety for Digital Alarm Communicator System Units - ANSI /UL 1635, 1996 (3rd edition) - Safety of Household Burglar Alarm System Units, ANSI /UL 1023, issued 1996/11/25 (6th edition) with revisions up to 12/30/04 • Commercial Burglary: - Standard for Safety for Police Station Connected Burglar Alarm Units and Systems - ANSI/UL 365 (4th edition), issued 1997/01/31 with revisions up to 2005/03/08 - Standard for Safety Local Burglar Alarm Units and Systems - UL 609 (11th edition), issued1996 /08/28 with revisions up to 2005/03/17 - Standard for Safety Central Station Burglar Alarm Units - ANSI /UL 1610 (3rd edition), issued 1998/10/26 with revisions up to 2005/08/16 Communications • VISTA -GSM Snap -in Dual -Path Digital Wireless Communicator (IP required for activation and registration) • Touchtone or pulse standard TELCO dialers • Formats supported - ADEMCO Contact ID - ADEMCO 4 + 2 Express - ADEMCO low speed - Sescoa/Radionics • 3 + 1, 4 + 1 and 4 + 2 reporting • Reporting capabilities - Split - Dual - Split/Dual - True dial tone detection • Low battery reports 11.2 - 11.6VDC • AC loss and restoral reporting supported ORDERING VISTA -21 iP Control Panel VISTA -21 iPSIA Control Panel for SIA Installations VISTA -GSM Optional Snap -in Radio Module VISTA -ULKT Cabinet for Listed Commercial Burglary Applications Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 arch 0 0 March 9 M 2009 www.honeywell.com 0 2009 Honeywell International Inc. Honeywell Honeywell 5192S D/5192S DT V -PLEX® SMOKE DETECTOR The Honeywell 5192 Series low profile, addressable V -Plex smoke detectors deliver state -of- the -art features and benefits in a cost - effective package. These detectors are designed to provide open area coverage and are compatible with Honeywell's VISTA controls supporting V -Plex technology. An LED on the detector will blink periodically during normal conditions, remain on steady during alarm and cease to pulse if the chamber is out of acceptable sensitivity range. An extremely powerful feature available within the 5192 Series is the Automatic Maintenance Alert/Reporting capability — a feature normally found in today's high end analog addressable systems. The detectors continually monitor their own sensitivity levels in addition to the basic normal and alarm conditions. These HIGH and LOW SENSITIVITY signals are communicated back to the FEATURES control, via the V -Plex addressable loop, to indicate locally and at the central station that the detector may not be able to detect smoke or may false alarm. This feature works with VISTA -32FB, 12813P, 128FBP, 25013P, 250FBP, 40, 50P, 100 -24 and FAP FA1600C, FA1660C and FA1700C. More important is the cost saving associated with Automatic Maintenance Reporting. The feature is an approved alternate to NFPA 72 field sensitivity calibration testing that require external test meters. This eliminates the need to schedule inspections to determine detector sensitivity/viability. Another important benefit of these V -Plex (addressable) smoke detectors is their ability to operate on existing wiring. There is no need to run special twisted pair, data grade or shielded wires, providing you with the right choice for all your retrofit applications. That equates to cost savings in time and materials! • Low profile design • Available with integral heat sensor • Lines on existing or conventional wiring • V -Plex addressable loop device • Automatic maintenance reporting APPLICATIONS • Simple 2 wire installation • DIP switch or serial number programmable The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V -Plex addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications. They are suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or professional office suites and in factory and warehouse environments. 5192SD/5192SDT V- PLEXT"^ SMOKE DETECTOR SPECIFICATIONS Installation The 5192 Series smoke detectors are supplied with a convenient mounting bracket that allows the detector to be mounted to a variety of electrical junction boxes. A removable terminal block, that accepts 14 to 22 gauge wire to provide easy wiring connections. The detectors are designed to meet all applicable requirements for UL Commercial and Residential Fire installations as well as NFPA 72 requirements when installed in compliance with the National Electric Code and approved listed control panels. _it W o z Q - W a J J 2 D� « m0 - - W (� LUW 0) DIP m F Q SWITCH REMOVABLE y d TERMINAL BLOCK >f 0 diagram for 5192SO/SDT smoke detector Wiring Compatibility Serial number addressing is supported on VISTA -32FB, 12813P, 128FBP, 25013P, 250FBP, 100 -24 and FAP FA1600C, FA1660C and FA1700C controls. (Refer to control panel and smoke detector installation instructions for details.) Automatic Maintenance Reporting Compatibility The automatic maintenance feature is compatible with the following control panels: - VISTA -32FB - VISTA -128BP - VISTA- 128FBP - VISTA -250BP - VISTA- 250FBP - FA1600C - FA1660C - FA1700C The automatic maintenance may be disabled for all other controls that do not support this feature. Refer to control panel and smoke detector Installation Instructions for details. Electrical: Mechanical: • Diameter: 5.5 inches (140mm) (including mounting bracket) • Height: 1.7 inches (43mm) (including mounting bracket) • Weight: 5.3 ounces (150 grams) Environmental: • Installation temperature range: 32° to 100 °F (0° to 38 °C) • Installation humidity range: 10% to 93% RH, non - condensing • Heat sensor (5192SDT only): 135oF fixed temperature electronic thermistor • EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - IEC EMC Directive Agency Listings • UL268 Commercial System Smoke Detector These smoke detectors are compatible with all VISTA control panels that support V -Plex (addressable) polling loop technology. The detectors support DIP switch or serial number addressing. DIP switch configuration are compatible with 5140XM, VISTA -40, and VISTA -50P controls. ORDERING • System voltage range: 7 -14 V Standby current (maximum @ 12V): - LED off: 1.2mA - LED on: 2.8mA • Meets UL 217 Requirements for Residential 5192SD Addressable Photoelectric Smoke Detector 5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor For more information: www.honeywell.com /security /hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 vet 200 ell.com May zoos www.honey 0 2009 Honeywell International Inc. Honeywell 6160 -- - ALPHA DISPLAY KEYPAD !` REP( WITH DOOR ATTACHED -- t e ' 2 _ 3 �' ^+ WITHOUT DOOR The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white console blends with any decor and features a contoured, removable door that conceals illuminated soft -touch keys. The 6160 also features a new larger and brighter 32- character display with easy -to -read plain - English status messages. FEATURES The oversized function keys are easily accessed even when the keypad door is closed, and can be programmed for fire, burglary, personal emergencies and other operations. Colored self- adhesive labels are included. • Large, easy -to -use keypad • Keys continuously backlit for greater visibility • Speaker with audible beeps to indicate: - System status - Entry/exit delay - Other alarm situations SPECIFICATIONS Physical • 5- 5/16 "H x 7 -3/8 "W x 1- 3/16 "D (135mm x 190mm x 30mm) Current • Standby -40mA • Activated Transmission -160mA • Zones and system events displayed in plain English • No confusing blinking lights • Four programmable function keys Wiring • - (Black): Ground • + (Red): +12 VDC (Aux. Power) • D1 (Green): "Data in" to control panel • DO (Yellow): "Data out' from control panel ORDERING 6160 Alpha Display Keypad Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com C0060 V6160 /D September 2006 0 2006 Honeywell International Inc. • System functions clearly labeled • Functions performed by just entering security code plus command • White with removable door blends with any decor Compatibility • Fully compatible with all VISTA controls. Honeywell SYSTEM SENSOR" Mini -Horns The SpectrAlert'Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. 7 S s Y e S e Features 12 and 24V operation • High and low volume settings • Temporal and non - temporal tones Mounts to single gang back box Compatible with MDL sync module Mechanically and electrically compatible with PA400 series Mini - Alert" sounders Agency Listings & FM MEA LISTED APPROVED approved " The MHR and MHW mini -horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini -horns offer high and low volume settings, and temporal or non - temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini -horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. SpectrAlert" Advance Mini -Horn Specifications Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini - horn shall be listed to Underwriter's Laboratories Standard UL.464 for fire protective signaling systems. Mini -horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync - Circuit Module, 12 -volt rated notification appliance Circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9W x .45 Weight 2.67 oz. Operating Temperature Range 32 "F to120°F(0 °C to 49 °C) Mounting Surface: single -gang back box Flush: 4 x 4 deep back box (2 Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8 -33 Operating Voltage with MDL 9 -33 UL Sound Output and Current Draw Data Switch Setting Pattern Output Level 8 -17.5 VDC 8 -17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16 -33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non - temporal High 72 71 75 74 80 79 4 Sounder Current Non- temporal Low Draw (mA RMS) 70 69 73 72 78 77 Switch Position Sound Pattern Volume 8 -17.5 Volts DC FWR 16 -33 Volts DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non - temporal High 22 17 29 25 4 Non - temporal Low 17 13 21 19 Ordering Information MHR Mini -Horn, Red MHW Mini -Horn, White 030075Yv—Sem— SYSTEM 3825 Ohio Avenue - St. Charles, IL 60174 Produc«,t— wa"„ oc— MWSYM —n—for SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 `— product t W—rflon, "lud'"g`*1awv"N""°rd'd`M'a`h� Aos -0414 - 000.1107.11743 $ c 0 � � � � c 0 I ra m m N C � � $ 3 13 0 � ■ u 2 � c V ■ N 2 .§ (A 2 N � � � o \ �- §§ E/ •> �� c 5� _� ƒ ( \ V)3 E E ° @ �2 = I �& _ �k \ j § {u \7 (D 5 E� /\ e ° 8 ) § /2 \± o£ = 2 ® � m :3 // 2 / u § ] \ /\ f W \} E \ k § i \ 7 r =_ E _ 2 _ 2 e CL® m e /E CD 2 «— / § / 0 - : 2 / \ o / / § 2 ■ s ' E - q: 2 { E � q / \ / $ ® E §k (/ \ kk % « § = k {$ f/f $t k\ k( / i. 7 w = o §! Vo § V ) — 0 N �� \ u E 0= •k> uo ® c �� �c ; �V� a' &2 = .0 2 > < ._x_ «$\ k/ / kcE Lm o /(\ CL 2 /\ Zuozƒ m 0 �� �of�. g7 a � 3 «(n ua 3 m,2 L. f i Vi a) o �j7�� � L. c 2= / ��2� §:0 5 =me c =c c o 4 2 » Q w 0 oo = a) 0 7 :» 'C L) U w a-i Ue -j Li- U. !!::a CO m N R fD Z J 0 rn N = W N 00 y C Mv) v V � v d N S a E Lm a a W .a O E V N_ a CL ` L i M o 0 y c W �� H C C y O V E i s V 0 M u T— U° Q cr 4) RT • CO m N R fD Z SYSTEM SENSOR" 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a low -cost means for property protection against fire, and for non -life- safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: - Single- and dual- circuit models - Fixed temp and combination fixed- temp /rate -of -rise 1357 or 1947 ratings. Plain housing for residential installations (Model 5601 P) Easy -to -use terminal screws A broad range of back box mounting options: - Single gang - 3.5 and 4 Octagonal -4 "square with square to round plaster ring • Reversible mounting bracket Agency Listings @ <FM > MEA LISTED APPROVE, approved Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual- circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature /rate -of -rise (ROR) activation. The ROR element of the fixed /ROR models is restorable to accommodate field- testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four- square back boxes, when used with a square to round plaster ring.The reversible mounting bracket permits both Flush- and surface -mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed /rate -of -rise units are marked FX /ROR.The 5600 series also provides a post- activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Specifications Arch itectu ral/Engi nee ring Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single- circuit or a dual- circuit type, normally open. The detector shall be rated for activation at either 135 "F (57'C) or 194 °F (90 °C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature /rate -of -rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15 °F (8.3 °C) per minute. The detector shall include a reversible mounting bracket for mounting to 3 -inch and 4 -inch octagonal, single gang, and 4 -inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14 -22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature /rate -of -rise models shall be restorable, to allow for field- testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/ Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100 °F (38 °C) 5602, 5604, 5622, and 5624:150'F (65.6 °C) Operating Humidity Range 5 to 95% RH non - condensing Dimensions with mounting bracket Diameter: 4.57 inches (I 1.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57 °C) 5602, 5604, 5622, and 5624:194 °F (90 °C) Weight 6 oz. (170 grams) Rate -of -Rise Threshold 15 °F (8.3 °C) rise per minute (models 5601 P, 5602,562 1, and 5622 only) Mounting 3 -inch octagonal back box 4 -inch octagonal back box Single gang back box 4 -inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage /Contact Ratings 6- 125VAC / 3A 6 -28VDC / 1 A 125VDC / 03A 250VDC / 0.1 A Input Terminals 14 -22 AWG No IN e lJ X1 C, 5601P 5602,5622 5603,5623 5604,5624 5621 5 S ingl e L e tte ring 194 °F ( °C) Fix Temp / Rate -of -Ri 5 0 f x 50 f eet ( 1 5.2 4m x 15.2m) 5603 Single Lettering 135 °F (57 °C) F i x ed T emperatu r e 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194 °F (90 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135 ° F (57 °C) Fixed Temperature / Rate - of - Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194 °F (90 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135 ° (57 °C) Fixed T emperature 25 f eet x 25 fe ( x 7. 5624 Dual Lettering 194 °F (90 °C) Fixed Temperature *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) f - SYSTEM SENSOR 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800- SENSOR2 • Fax: 630-377-6495 02006 sytem Sen.— P,°a,�ts�,�at­s,mj�toa,angewRh moce\49tsntr°u� : «�,,,ro, """'t r "A"`t'"r°""a#MMk1d"19 the IaWt°""` Offts'aMSheet. A05 0351 -002• 11/06• 91676 5601 P Single None 135 °F (57 °C) Fixed Tem R -of -Rise 50 f eet x 50 f e e t ( 15.24m x 1 5.2 m)