i NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
1
t
TOWAVAIC
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
t
i
MECHANICAL PERMIT Permit #: M10 -0218
AMF Project #: PRJ10 -0650
{
Job Address: 4506 SPRUCE WAY VAIL Status ...: ISSUED
i Location • UNIT 1 Applied ..: 10/08/2010
Parcel No...: 210112304001 Issued . . : 10/15/2010
+ Expires . .: 04/13/2011
OWNER WHEELOCK, G. RICHARD, SR, MA 10/08/2010
G. RICHARD, JR
PO BOX 6391
AVON
+ CO 81620
APPLICANT J G PLUMBING & HEATING INC 10/08/2010 Phone: 970 - 827 -5338
PO BOX 245
i RED CLIFF
CO 81649
License: 340 -M
CONTRACTOR J G PLUMBING & HEATING INC 10/08/2010 Phone: 970 - 827 -5338
PO BOX 245
1 RED CLIFF
1 CO 81649
/ License: 340 -M
1
Desciption: REPLACE OLD BOILER WITH NEW HIGH EFFICIENCY BOILER.
Valuation: $7,800.00
1
1
......**************************************** * * * * ***** * *n* * * *** * * * *** * * * **** *FEE SUMMARY * * *n* * ** * * ** * * * *n* * * *n* * * *_* * * *.* * * *n**** ** * *n* * * *n* * * *_* * * *..... *n**
Mechanical Permit Fee - -> $160.00 Will Call > $4.00 Total Calculated Fees - - -> $204.00
Plan Check > $40.00 Use Tax Fee > $0.00 Additional Fees- > $0.00
Investigation -- - -> $0.00 TOTAL PERMIT FEE - - -> $204.00
1
i Total Calculated Fees > $204.00 Payments ---> $204.00
1 BALANCE DUE > $0.00
1 ****************.*******. .***************************.**************************************************************************************************** * *** * * * *** * * * ***** * *** * ***.* * **
APPROVALS
Item: 05100 BUILDING DEPARTMENT
1 10/15/2010 JRM Action: AP
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
1 REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0(
AM -4 PM.
I ''` fei(4(0 ,
1 Signature of Owner or Contractor Date l
1
Print Name
mechcanical_permit_041908
i
TOWN OF VAIL, COLORADO Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: R100001598 Amount: $204.00 10/15/201004:42 PM
Payment Method: Check Init: SAB
Notation: 2577 G.
RICHARD WHEELOCK
Permit No: M10 -0218 Type: MECHANICAL PERMIT
Parcel No: 2101 - 123 - 0400 -1
Site Address: 4506 SPRUCE WAY VAIL
x
Location: UNIT 1
Total Fees: $204.00
This Payment: $204.00 Total ALL Pmts: $204.00
Balance: $0.00
ACCOUNT ITEM LIST:
3 Account Code Description Current Pmts
MP 00100003111100 MECHANICAL PERMIT FEES 160.00
PF 00100003112300 PLAN CHECK FEES 40.00
WC 00100003112800 WILL CALL INSPECTION FEE 4.00
,
1
Sy
/
1 _�
a
4)‘
0
( f) s C 2 1 —
q
1 0,4 ‘ 4
5 4- 1# ClAck5
C
1—
. = , ,, „ ;_, . Department of Community Development, !
75 South Frontage Ro d
�,. , _ VaII $or • i , '
9.„ ; a5; } a t k q{
.,... _ , r 37g✓ S 'r ye -;, ' ` z., a
MECHANICAL PERMIT
1
Boiler / Furnace & Fireplace Applications MUST include:
❑ Complete Mechanical Room Floor Plan with Dimensions � Boiler size &efficiency
❑ Combustion Air Duct Size and Location ❑ Equipment Cut Sheets for Fireplaces /Log Sets
❑ Flue detail or Vent size, location & termination (Manufacturer's info showing make, model & approval listing)
❑ Gas Piping layout including development length calculations Office Use:
❑ Heat Loss Calculations Project #: f)PS /D -- D ( o '
1
Project Street Address: Building Permit #: —
4/5(i s /gUC 41 1- Mechanical Permit #: fy) 10 Ina / S
(Number) (Street) (Suite #)
i
Lot #: Block # Subdivision:
Building /Complex Name: '
Define Scope and Location of Work: 1?.cP (�
Contractor Information: --, ? - / /
Company: SG (Itu v�bl P / iclt ZINC, 6 _0 I ]o I / 1A k 'W c r
Company Address: AG 9 .spAu c-5,_ c
City: l 4 - CI, State: CP Zip:
w �
/^ �q (use additional sheet if necessary) t
Contact Name: �p 51 1 C7 / 'c5 L 4
d * Gas Piping Included
Contact Phone: 170 3 ?:0 - 9' j 3 O o Gas Piping by Others l
i
E -Mail
❑ Wood to Gas Fireplace Conversion
Town of Vai antractor P.-gistration No.: 3 _- ) ' I r) Boiler Location:
. Interior (X Exterior ( ) Other ( )
X
Number of Existing Fireplaces:
ont; • o Signa ure (required) r
Gas Appliances Gas Logs Wood /Pellet
Property Information AA
Parcel #: Q 0 i Number of Proposed Fireplaces:
(For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or Gas Appliances Gas Logs Wood /Pellet
visit www.eaglecounty.us/patie) 1
Type of Building: t
Tenant Name: t
(Commercial roperties) Single - Family ( ) Duplex ( ) Multi - Family _ l j Commercia ( ) ,
( / Restaurant ( ) Other ( ) ' `
Owner Name: �l G �,�^ � [�} VtP�'(�C/
Date Received:
Complete Valuation for Mechanical Permit: (including fireplaces) n L5 \'J
Mechanical $: ei ' 7��a` u
� d 5 OCT 0 7 2010 1))
TOWN OF VAIL
i
i
C: \cdev \forms\ permits\ building \mechanical permit_010110
)
s 6, A.
- 1�
t
the best C) ,..f .
mod /con Performance
and V ersa t i li ty �
�,o
DoE ASE ':
it
KN f y
;� 7.- III
" � "- KLuo,a,.
L .-, , ":3,4r4 -
1. rPo ' 7,`
1 7NIGHT
t Now with Floor and
HEATING BOILE
Wall Mount Models
II '
f
Ili DESIGN
ETD
1 i I )EALER DESIGN EXCEIIENCE IN
AWARDS DESIGN
fi� F
ANA
•
t "Ir ' - .::-: .
/U Lo chinvar®
e - k ,, High Efficiency Water Heaters, Boilers and Pool Heaters
� '.. � ¢ P
. www.knightheatingboiler.com
d
.,
a Legendary
Performer...
KN ■GH
• N
HEATING BOILER
Since its introduction in 2005, the KNIGHT operating control that has quickly become a
modulating- condensing heating boiler legendary benchmark among the trade!
has consistently delivered everything the
professional needs for ease of installation and For traditional space heating or radiant floor
maintenance, and everything homeowners heating applications, KNIGHT offers your
need for total comfort and long -term savings customers tremendous savings on energy
on energy costs.
costs compared to less efficient boilers.
KNIGHT has earned the ENERGY STAR,
Now, with 5 floor - standing models and 5 r il.111111 9 signifying that it has met ,../
compact Wall Mount units, Lochinvar * strict energy - efficiency guide -
offers the industry's broadest selection of lines set by the EPA and U.S.
modulating- condensing heating boilers. ENERGY STAR Department of Energy.
And KNIGHT is the industry's most advanced
boiler design, including the SMART SYSTEM —
10 Models — The Right Choice, for Every Application
'` ; +III,
-
_ _
a ` �\ _ i
, ) \ -;/'' - '
"After my first KNIGHT installation, / loved it so KNIGHT is a great choice for radiant
much l installed it in my own home, and now my floor heating, baseboard and panel
,,,
heater applications.
heating bill is half what it used to be."
- Rick Brunner, Hydronic Solutions, Nassau County, NY
SMART
SYSTEM
e ri u st r SMART SYSTEM is the industry's
most advanced operating control.
Right out of the box, it gives you
S m a rte st Design unequaled control and monitoring
functions that are easy to
understand and use.
`greatly like the KNIGHT Boiler because its verysimple to install
i l
and program. The SMART SYSTEM control is great and l really
I like being able to troubleshoot with the pocket PC My customers
choose KNIGHT for its high efficiency and state -of the -art design,
and they're all thrilled that KNIGHT operates so quietly and makes IGNITION their home much more comfortable." DUL lc?( 1_�]
imr
l , - Chad Padilla, TLC Plumbing, Albuquerque, NM
2 -Line, i6- Character LCD Display Night Setback ,
NIGH
Displays setup and diagnostic Program a heating loop water HEATING e o �L ER
information in words, not codes temperature setback for any time i
of the day, each day of the week """ 3.7
Password Security M111
Dual passwords forinstallerand user Building Management System
(BMS) Control -1 ' ochinVa -
Product Service Indicator 0 -10 VDC, BMS- driven input for
Program reminders for cycle count, modulation rate or temperature control
operation hours or last service
DHWP with Pump Control
Pump Relay w/Freeze Protection On call for hot water, SMART SYSTEM
Ensures water temperature does overrides outdoor reset and starts DHWP
not fall below40 °F pump to the indirect. Runtime can
alternate between heating and domestic
1 Low - Water Flow Indicator hot water to meet demand simultaneously
Protects against high temperature ..=R PC Connection —
differential in the heat exchanger with System & Boiler Pump Control __ _
reduced modulation or shutdown Provides power to both system and C ,q used with KNIGHT
boiler pumps based on a call for heat. and pr gra to o troubleshoot
Programmable delay allows pumps to and program SMART SYSTEM
Outdoor Reset functions and to track
operate after a call has been satisfied
Outdoor temperature monitor guides the historical data, including
reset schedule to meet load In /Out Temp. Sensors and Display -.: faults, trends and
P y energy consumption.
Allows installer to select which sensor
I controls the boilersetpoint
f
Field Connection Versatility
User- friendly terminal strip allows for 28 E `°
low - voltage field connections. Plus, 4 line °^ °��` -- ; AT- my'rek
u y
voltage connections supply power to the unit, F " `fi
««
and up to three pumps operated by the N = t
SMART SYSTEM.
Built - in Cascading Sequencer : - - "The control system on
the KNIGHT is head and
SMART SYSTEM includes a built -in sequencer shoulders above anything
for 2 -8 units, eliminating the cost and labor 1.0.0 °^° else available. Straight out
of a third -party sequencer. On demand, one °a.,°�,
° ° _ of the box, the KNIGHT can do
boiler acts as lead unit and modulates with v.% =�r:t
demand to meet capacity. The additional load anything /need wo ws, i it's third- h party
then "cascades" to the next boiler in line controls. Hands -d t's the best
and continues all are operating or demand ° « ° « ° boiler on the market "
is satisfied. When demand drops, the ZE lh E R I E E Ill.*. — Don Smet, Standard Plumbing Heating reverses. i ° ®s Ill, ' g g
Controls Corp., Spokane, WA
TM
WALL MOUNT BOILER
is J oone d at the
Table
d Roun .� _,.;
i ,
----- "Why do I like the KNIGHT. l don't know where to begin. The direct venting
al 6 a .' . A_ with 100 feet of intake and exhaust eliminates a lot of problems. I also like
the low voltage features, and the SMART SYSTEM'S outdoor reset capability.
;Pee The internal sequencer is tremendously powerful and ideal for multiple boiler
installations. It's also great - looking, and aesthetics are important to my
k W customers. When I install KNIGHT, my customers know they are getting a
BE
highly efficient state -of- the -art system, and they've all been completely satisfied.
— Paul Rohrs, Biggerstaff f Radiant Solutions, Lincoln, NE
KNIGHT lineup now includes 5 space- saving
Wall Mount models from 50,000 to 210,000 Btu /hr
II -
f aq ir
( Low NOK All KNIGHT Boilers
Certified meet or exceed
The KNIGHT floor - standing o�,' the highest federal
r
4 emissions
lineup features 5 small ' "c +E ■■ ` requirements. footprint designs from
80,000 to 285,000 Btu /hr
KNIGHT plus SQUIRE delivers domestic hot water for less!
The KNIGHT boiler's DHWP feature means you can easily install it with
Lochinvar's new SQUIRE indirect water heater. With this winning combination,
homeowners will get high - efficiency space heating from KNIGHT, plus all the
domestic hot water they need from SQUIRE. Equipped with a stainless steel '
tank and heat exchanger, SQUIRE will provide more hot water with lower water
heating costs compared to a standard gas or electric water heater.
N ilk
o
0 / O ADO
with Duali 0
DOE AFlJE ��
Efficiency _ i
and I �� e .
__
, "I'm very impressed with the KNIGHT Boiler. It lightweight, simple to install and works remarkably well. — � ' alit
The SMART SYSTEM control is a definite advantage, because most other manufacturers sell the control i
} separately and it has to be assembled on the job. I also really like that the KNIGHT can modulate down to ; i -
20 percent, and that the wiring is very easy to understand. I recommend the KNIGHT to all of my customers 1 "*l
who are looking for a quality boiler that will perform well and last for years."
, – Steve Ayotte, Ayotte's Water Works, Lansing, Ml
''
Advanced Negative Regulation Technology
KNIGHTsafely and reliably operates with supply gas pressure as low as 4 inches
water column, because "Neg /Reg" technology automatically adjusts gas
41...... .. pressure to ensure the correct volume of fuel and air entering the burner. •
` Fail -Safe Direct -Spark Ignition: ''
• With each call for heat, two electrodes ignite the fuel /gas mixture. A third ' 4.
electrode then senses for flame. If no flame is detected, the system resets and
.. attempts ignition four times. SMART SYSTEM will lockout and display the fault
if ignition does not occur after four attempts.
0 Pl. A to
Two -in -One Stainless Steel Heat Exchanger
A primary heat exchanger combined with a secondary heat exchanger i
capturing flue gas heat allows entering water temperatures as low as 50 °F. , 1
The stainless steel, pH- tolerant design features a weld- sealed assembl wi i , r _ f
no 0 -rings or gaskets and does not require special glycol. ASME Secti IV
approved and stamped.
Fully Modulating Burner with 5:1 Turndown i
The SMART SYSTEM allows fully modulating combustion with 5:1 turndown.
The burner can fire as low as 20% of maximum input, and modulates the •
•
firing rate up to 100% as demand increases. The woven stainless steel mesh
assembly fires in a 360 pattern along the entire length of the heat exchanger.
These together allow KNIGHT'S compact size to excel compared to units with
larger multiple burners.
Ease of Installation
111F , far
Direct Venting up to 100 Feet!
1,,
KNIGHT offers greater flexibility than other boilers for placement of units within ,, 1 I +i
the building, because it permits direct -vent air intake and exhaust runs up to 100 "'
equivalent feet, using 3" PVC or CPVC pipe. Wall mounted KNIGHT models (50-105) j
also permit intake and vent runs up to 40 feet using 2" pipe. Intake and exhaust 4 t 1 Nov
runs can terminate horizontally through a sidewall or vertically through the roof. r +
. ' _. ''"
! ___
Knight Heating Boiler Dimensions & Specifications— Floor Standing Models Wall Mount Models
I .-_ K I • 16"
III
I% % - �{ 7-1/2"
CONNECTIONS H I
-- -_ - AIR INLET � I I � II 7
I
III INLET OUTLET
t 6
J GAS
A
30-1/4 29-3/4 FLU ~ • l FLUE I 0 AIR INLET
I DRAIN ���
H . DRAIN TOP
CONDENSATE
18-1/2"
11 -1/
rn DRAIN ■■
� j■ ■ 01�
•■■■• / G 6 -1/2"
+ i
7-3/4"-.1 ADJUSTABLE
F E 1 /4' - 1 -1/4"
Models: 1 ,s -,/z° 3 D C Models:
KBN80 - 230 BACK LEFT SIDE FRONT A WBN050 - 210
F- - -J
ELECTRICAL I� Ike"
�� � ` CONNECTIONS
\� \`
, , GAS
�` ill 1 !: -1
K AIR INLET SIDE C
ELECTRICAL
INLET OUTLET _
I l CONNECTIONS
A G AS
3 9 -1/2" 39"
1 Z H , d � ��oo.' oo
DRAIN
FL l1E r 3/4" NP7 OUTLET -
.r ti lt
CONDENSATE E
1B -3/4" D RAIN
13 -3/4" _ K F +
I G p O 1 -3/4"
j .
G + 4I1 —f
Model: B- F� ADJUSTABL INLET 3"
CONDENSATE
E 1/4 "- 1 -1/4" 8 -1/4' DRAIN
KBN285 15 -1/2" - 2 -1/2- = D c BOTTOM 16 -//2"
cL' H KNIGHT Heating Boiler Ij 'r Dimensions and Specifications
Input Heating NET
Model Min Max AFUE Capacity I =B =R Gas Water Air Vent Shipping
I Number MBH MBH % MBH MBH A C D E F G H I 1 K M Conn. Conn. Inlet Size Weight
WBN050 10 50 95.3 45 39 29 -1/4" 15 -3/4" NA 10 -3/4" 10 -3/4" 2" 6-3/4" NA 3 - 1/4" 4 -1/4" 2 -3/4" 1/2" 1" 2" 2" 130
WBN080 16 80 95.3 72 63 29-1/4" 15 -3/4" NA 10 -3/4" 10 -3/4" 2" 6-3/4" NA 3 - 1/4" 4 - 1/4" 2 - 3/4" 1/2" 1" 2" 2" 130
WBN105 21 105 95.4 97 82 29 -1/4" 15 -3/4" NA 10 -3/4" 10 -3/4" 3 -1/2" 5-1/2" NA 3 -1/4" 4 -1/4" 2 - 3/4" 1/2" 1" 2" 2" 134
WBN150 30 150 95.5 135 119 29 -1/4" 20 -3/4" NA 15 -3/4" 8 -1/2" 3 -1/2" 5 -1/2" NA 8 -3/4" 9-3/4" 1 -1/2" 1/2" 1" 3" 3" 162
WBN210 42 210 95.7 190 165 29 -1/4" 25" NA 20" 12" 3 -1/2" 5 -1/2" NA 13" 14" 1 - 1/2" 1/2" 1" 3" 3" 177
KBN080 16 80 95.3 72 63 33 -1/4" 14" 7" 5-3/4" 5" 3" 20 -1/2" 22" 1 -3/4" 6 -1/2" NA 1/2" 1" 3" 3" 125
KBN105 21 105 95.4 97 82 33 -1/4" 14" 6-1/2" 5-3/4" 4 -1/2" 1 -1/2" 20 -1/2" 22" 1 -3/4" 6 -1/2" NA 1/2" 1" 3" 3" 129
KBN150 30 150 95.5 135 119 33-1/4" 18" 12 -1/4" 11 -1/2" 10" 1 -1/2" 21 -1/4" 23" 1 -3/4" 12" NA 1/2" 1" 3" 3" 157
KBN210 42 210 95.7 190 165 33 -1/4" 22 -1/4" 16 -1/2" 15-3/4" 14 -1/4" 5 -1/4" 21 -1/4" 23" 1 -3/4" 16 -1/4" NA 1/2" 1" 3" 3" 172
KBN285 57 285 96.0 260 226 42 -1/2" 19 - 3/4" 12 - 3/4" 13 6" 2" 34" 31" 11 -3/4" 4 -1/4" NA 3/4" 1 - 1/4" 4" 4" 224
Notes: Performance data based on manufacturer's test results. Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models.
Standard Features SMART SYSTEMTM Features Optional Equipment
> Energy Star® Qualified > SMART SYSTEM Digital Operating Control > Adjustable High Limit w/ Manual Reset
> Up to 96% DOE AFUE Efficiency > 2 line, 16 Character Display > Flow Switch
> Modulating Burner with 5:1 Turndown > Dual Level Password Security > Low Water Cutoff w /Manual Reset & Test
> Direct -Spark Ignition > Domestic Hot Water Prioritization > Alarm Bell on Any Failure
> Low NOx Operation > Built in Cascading Sequencer for up to 8 Boilers > Concentric Vent Kit
> Field Convertible from Natural to LP Gas > o-io VDC Input Control > Condensate Neutralization Kit
> Vertical & Horizontal Direct -Vent > Outdoor Reset Control with Outdoor Air Sensor > SMART SYSTEM PC Software
> PVC or CPVC Venting up to loo Feet > Low Water Flow Safety Control & Indication
> Factory Supplied Sidewall Vent Termination > Alarm on Any Failure Contacts > Multi -Stack Frame
> ASME Stainless Steel Heat Exchanger > Service Reminder
> Automatic Reset High Limit > Freeze Protection Firing Codes
> Inlet & Outlet Temperature Sensors > Night Setback > M9 Standard Construction
> Boiler Circulating Pump > Time Clock > M7 California Code
>3o psi ASME Relief Valve > Three Pump Control (System, Boiler & DHWP)
> Adjustable Leveling Legs (KB Models only) > Data Logging
> Wall Mount Bracket (WB Models only) > Examples: Hours Running, Space Heating
> Zero Clearances to Combustible Material > Programmable System Efficiency Optimizers
> 12 Year Limited Warranty > Examples: Anti - cycling, Ramp Delay
.....)
(See Warranty for Details) _
AL°' e IIJ Imo` Lochinvar
MEMBER "" " "° ' �I ® --
1 r 1 1 t 0 1 High Emcienec Nater Heaters, Boilers and Pool Heaters
■
300 Maddox Simpson Parkway, Lebanon, TN 37090 1 615-889-8900 1 fax: 615-547-1000 1 www.lochinvar.com
KBN -04 (Revised KBN -04 2/08) MK- 20M- I1 /08- Printed in U.S.A.
12 -17 -2010 Inspection Request Reporting Page 17
4:30 pm Vail, CO - CitV Of
Requested Inspect Date: Monday, December 20, 2010
Inspection Area: JRM
Site Address: 4506 SPRUCE WAY VAIL
UNIT 1
A/P /D Information
Activity: M10 -0218 Type: B -MECH Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: Insp Area: JRM
Owner: WHEELOCK, G. RICHARD, SR, MARY E. &
Contractor: J G PLUMBING & HEATING INC Phone: 970 - 827 -5338
Description: REPLACE OLD BOILER WITH NEW HIGH EFFICIENCY BOILER.
Requested Inspection(s)
Item: 390 MECH -Final
Requestor:
Comments: 390 -94
Assigned To: J ON
Action:
Inspection History
Item:
200 MECH -Rough
Item:
310 MECH- Heafing
Item:
315 PLMB -Gas Piping
Item:
320 MECH - Exhaust Hoods
Item:
330 MECH - Supply Air
Item:
340 MECH -Misc.
Item:
390 MECH -Final
Time Exp:
Requested Time: 02:00 PM
Phone:
Entered By: MHAEBERLE K
REPT131 Run Id: 12306