HomeMy WebLinkAboutVAIL VILLAGE WEST FILING 1 LOT 19.pdf GENERAL
1. DESIGN LIVE LOADS: Snow=85psf, Floor=40psf, Wind 90mph (3 Second
Gust), Seismic Zone B
2. RESPONSIBILITY: The contractor is responsible for cross referencing all
plans and inspecting work placement at the site to assure that no 4�-9 1/4�� 7' �
omissions or discrepancies exist that might adversely qffect construction or �
the integrity of the finished product. Job site and construction safety are � �
not addressed in these plans and pre the responsibility of the contractor. c�
These responsibilities are industry standard. i i
3. These plans are intended to be in accordance with 2003 IBC and IRC
codes. All construction to be in conformance with these codes. � �
� i
FOUNDATION � ' -�- '-L , 6x6
1. Foundation designed assuming maximum allowable soil bepring pressure ' ( Post
= 2000 psf, no min. Verify these values and forward to Engineering Design � •- • - •- •�
Works prior to final grading of excavation or placing concrete. Different soil I � � �
values and requirements may affect foundation design. � .___ ._. � �
2. We recommend a Colorado Registered Professional Engineer verify � � J �
during excavation (and before construction of any part of the foundation) • � � �
that soils types and conditions warrant the assumed values noted above. 2x6 Decking �� � • N � � i� �
Engineering Design Works, Inc. assumes no liability for damQge to structure 5 1� x12 or 3 7g'x12 GL Rim � ' r.
resulting from soil expansion or settlement due to assuming improper soii Let Into Post 3" min. (NP) � . - . - . - . i � � � �g �
bearing values. 2x12 At (2�5,g� Thru Bolts � r �
3. Remove topsoiis, organic material, and any questionabie material below 16"oc Joist ' "� v ��$��
pads and footers. All pads and footings exposed to frost must maintain � i i ° ��.�
the required 4' frost depth. Minimum pad thickness = 12". The footing LUS210 _j, j � �a.5 m
elevations of this design are indicated in economical relation to �" ' - '- ' � � � ��,��, <
architectural elements. Proper soil bearing may require lower footings. �I '-- � -� � �� a�
4. Drainage and grading details to divert surface drainage at least 10' !�- �- �- �- �� 1�� �°����o
away from the structure. � 2x12 At 16"oc � � F� ���� � '
5. Exterior backfill may be native inorganic material. Before placing finish � ._ ._ . _, � � ��•���
topsoil, we recommend capping backfill with a Mirafi fabric under 12"-24'� 6x6 � � J d- ��•�� �
of water impermeable material (e.g. clay). ' � c� � o ����.�� `:
6. All construction and materials to conform with ACI 318. � �- �- ' -' . � � � a� '
. �,8.
7. Reinforcing bor to be deformed 60 ksi steel (per ASTM A-615). Lap CB or PB per plan � I � `� a.� �s �a
all rebar splices and corners 30 bar diameters minimum. � �- �- �- • -� =" a, � � �,m o :
8. Minimum concrete 28 day compressive strength = 3500psi. Maintain 8" C�earance between Top � � M � �-����
9. Concrete cover: Concrete cast against and permanently exposed to of Pier and Soils at F�n�sh Grade � .- .- . - .�
earth: footing, pad = 3". Concrete exposed to earth or weather: FiNisH cw�E
� 6x6 I--�
piers=l.5" „ ' �_ � _ Post �----� �
10. Consolidpte concrete per ACI 309. � � � � � � w
12"� Pier i i � i ^
WOOD FRAMING I� '_ ' _ ' .-�' -i' _ ' - .- '- '-i' i F--�
1. Framing plans show structural requirements only. Additional members (3)#4 Vert. Reinf.' I L___-J �_ . - 6x6 �
may be required for blocking, nailers and code requirements. � Hook into Ftg.� - �1�_9 1�4" i • - •- •- •- • - •- • - • - •- •- •i Post
2. Use DF#2 (S4S) or better for all muiti-stud posts, joists, rafters, ��v�,
headers, posts, beams and plates. �, , � �C�/ 8'-2" -�{ 3�-7 1/4" � • �
3. Sill plates and any other lumber in direct contact with concrete- �' #4 � 6 oc E.W. � � "- '- �- ' - � - ' - '- ' - '- '- '� � o
California Foundation Grode Redwood or Species Group B Pressure Treated � � � °O
Lumber. _ � �- � - � - • - � - � - � - � - � - �- � � � � w o �U � ,n
4. Glulams (GL)- 24F-V8 manufactured in accordance with AITC 117-84, °N� °a � � _ � �T1 � � �
U � �
fb=2400psi. OK to use 24F-V4 for simple span applications only. All �� a �- .- . - .- .-.- . - . - .- . - . - . _.} N � �'�'� ,o,� � � �;'
Glulams used in exterior applications must be sealed and protected from � � ic � �v� o�
moisture with an appropriate preservative. _ _ _ ' � ° 1-� .� � � � °r.,°
Mai tain 6" clearan b t ted ood or sidin soils at � � ��--PT2x12»Ledger �� � �F� a� � "o
5. n c e e t w e e n u n r e a w g a n d 24"x24" Pad � w/(2� � L a g s A t 1 6 o c • '�`� `.J `� p � rn
finish grade. (3j� � � ..
6. Posts to stack over equal below ��NO�. E X I S TI N G H 0 U S E � T � 6x6 ��T� q O a�i � �
7. Solid block all posts for continuit y to foundation. � � Pos t w �
8. Nailing, blocking, and all other construction details per 2003 IBC and ;� __._ ._ , _ , _ _ _ _ _r�. _ W G�. �n a w
IRC, such as Table R602.3(1). (UNO) � �
i i
9. All connectar callouts to be Simpson Strong-Tie or equal by Simpson A E X TE R i O R P A D P I E R D E TA I L /-� ; �� �
Stron Tie Com an , Inc. Install er manufacturer s instructions. � LUS210 � � � � � � � � �
9- P Y P � S1 Scale: 1 /2��=1 �-O'� M 24"x24"x12" Pad ' '---' -�
�with 12'�� Pier �TMP�
N �-- . - .- .- . - •- •- -- � - � - �- �-� DATE:8-11-06
TYPICAL ABBREVIATIONS i- i(TYPICAL) � 2x12 At 16'oc A JOB#:06110
� . _ , _ ._,- . - . - . ' ._ .- .- . Si DRAWN: CB
BRG_=centerin9ne 6x6 � - -� � �-n,P� � _ ENG: CW �
LUS210 E
E.E. = each end Post •---• -•- • - •-•- • - • - • -• � �- •- •- • - . - •- • � .- -- •- � -• -3i � � REVISED: ----
E.M. = each member 'I � 2x6 Decking .- REVISED: ----
E.S. = each side . � �f- .- . - . _. _ . - . -. - . _ . -. - . - ._ . c� rn
-3? �� -� - �- • - - � � �
E.W. = each way .. � � � �
Existing 2x6 � Ply � � , � � �x o
HDR Glheader Wa11 0 � � NOTE: CONTRACTOR VERIFY ALL � �-�- � - � �- � - �� �
I N � ^ I EXISTING COPJSTRUCTION IS IN GOOD � � � ISSUE: PERMIT SE'�
ML = Micro-lam Flashing Per � � '
oc = on center � X �� -' -� -� - ' - � -� - '-' - ' - ' CONDITION ANp BUILT AS ANTICIPATE:D. ��-�- �- � �- �----3�
Contractor �� • �� NOTIFY ENGINEER OF ANY
OF = overframe 2x6 Decking � � PT2x12�Ledger �� I DISCREPENCIES BETWEEN ANTICIPATED I •
OH = overhang r� f- � -� - • -• - -3�! !�-- -- •- � •- • - � (� RF�jJ
OPP SIM = opposite similar r- -, w/(2)3'Z'� Lags At 16 oc AND ACTUAL FRAMING. i- -� �hiO sj�
II - � • �RA�l�
PT = pressure treated i i LUS210 � .'• i� . j < ;�P �a��,:
_ _ _ _ _ _ _ �O p °•
I I I 1 .�
PSL = parallam ' � 6x6 � _ _.; �NP� I J� 6x6 �� �'�OG v�i.
R.O. = Rou h o enin Existing Cant. Joist 2x12 At 16'oc . _ . _._ . _. _ . _. _ , _. _. � � ��
9 P 9 � Deck Joist Post „ �� � � � � � � �- � � � ��� Post .� 34��1 2� '� �
SOG = slab on grade ' 2x12 At 16 oc ' 'I �� a'� ��
STR = Structural � -� �.`\�,
lYP = Typical = LUS210 � 'E- �- � - � - � - � - � ._. T . - .�/• � - . �.'•••..,•"• �•
UNO = Unless noted otherwise u +� N �� T I �� �� � ` � �
New 5 7� x12 GL PT 2x12 Ledger \ (TYP)_ . _._. _. _. T. _. _ . 24 x24 x12' Pad � a� � � ss'����`�5.�'
WS = steel web stiffeners Beam Per Plan w 2 �x ° 9 � � ^ v
/( �'2 5 La s at � � � � Existing 2x6 At 16"oc with 12"� Pier � �' v
16'oc I • -- Bearing Walls (NP) --- (1YPICAL) ' ,�ry �
Toenail existing Rim to � �-. - . - . _. _. -. - . _. -. . - . - . -3{ - - ---- --------- -- --------- ---- ----- ---- �. ,� o0
�' - ' -. _ . T"- ' - '�
beam with 16d at 16"oc � � 6x6 Post � 6x6 Post 6x6 Post , � 6x6 Post I �� �
of- � -� -� - � -� -� -- -� - �-� - � , �E � -�- �- •- �- �
o New 6x6 Post _ GLTS , 3 Cantilevered � _ 3 Cantilevered , LUS210-2 �7
r- � r- - � F1oor System r ---� New Dropped 5 Y$"x12 GL Below r- - ' Floor System r - -� (TYP) r --- �
i � � � -5 1�"x12" GL (�usH)-�-� �� � - - - � � Cantilevered Floor Rim -� / i�•- -•-•- -.r._._�. �f i 2)2x12' 'i i
i � "fi".�_� �..�_�.�..� _.�._._. . . . .._ _._._.� _ ._._. . . i�'�"'� i
� . � . . . . . . � . ��. �. �. _ . . � �. �. ^�•�,• �1 �i'7 r}7 � • r�i �• -� • � • �i'l � • � •I I 'l3
6X6 J i i i ��� � . - -J � � - --J I I I I L- -- ^� I I `�' �_ __ LUS210-2 L- - �
Post � � Run Dropped GL 3 Long And - � � . . LU�210- , . � � � . �PT2x12 Ledger � � � � � � � � �1YP�i � 6x6 �
I I Bear Flush GL On Top ' � � � � � (P'P) � � � � � � w/(2�'2"� Lags �4t 16"oc � � � � � � � ( � ' � Post s�
• Provide (2)Si�" Lag Connection � I I I I I � ( B I I I I � I I I I I I I � � . O
I I I I I I I � � . . . . . � • S1 - - � . . . • - - - • . I I I I I I � � � a �
� i i i i i i i i i � � � I I � ! , � � � I I I � � � � � � I I I � � � i � i � � o
B COI�JNECTION DETAIL B � � � - � � - �� � � � - � > > - . . o z
� 2 3/ 11 -9 1/2' 11'-5 1/4' 11 -9 1/2' 5 � �
S1 Scale:: 3/4"=1 '-O" � � I I I I I I . � . . . . . . . . - I c� � O
N Ni i i i i i i � � i i i I I . i i i � l I I i i i i i i I I I i i i i � i N N �
a. � � � � � � � I I � � I 2x fi Dec king I iD � � � � � � � � � � � � � � � � � I � G�, �
� I
"' I I I I I I I � � I I I I I i ��_. � Q I I I I I I I I I I I I � � � � I � �, � � O
I I I I I I I � � I I I I I . � N I I I I I I f I I � I i I I I � � � � c.�
I I I I I I I � � I I I � � � I I I N I I I � I I I I I � � � I I I � � � � a
. . . . . . . � � �-, � � � � LUS210� � � � ,-�---� � � � � � � � � ��-- �_, � � � � � � � � A r�� a �
i- -I-� I I I I I I - ,---- i . . � �(rrP) � - i i � . . . . . i i � � . . . - ir-- -i V W
� w.�...�._w.�.�._:�. :�.�.�.._:!f.�.�._:�-�. .�. .�._:�.�.�._:�.:�.�._.:�. :�.�.�._:�.�.�._:� � � � a
� • , a
6x6 � _ _� 5 7�"x12" GL Rim 6x6 � ____� 5 J�"x12" GL Rim 6x6 � _ __� 5 �"x12" GL Rim 6x6 � ____� 5 }�"x12" GL Rim 6x6 � __ _� O Q a �
Post Post Post Post Post � ��� _- _ ,�_ _ „� � w
24"x24"x 12" Pad �����, ��-� iJT_� ���'�� ��� �
A with 12°� Pier � �}�► �
Sl (TYPICAL) �J � [� � •
�u�7 1 J �°�; �
(� ��� i i, O O
, , � � ....�
12' 14 -0 1 4 14'-0 1/4"� �2 7
......... ..... ........... ..... .
�.�.�.�.��k°����_��V� �/<fi�,��... ,
� PAGE
#06110 of 1
����°� �f �f��l
�` � ,���`�-� �;��
�,;��� � ;�