HomeMy WebLinkAboutF10-0088 permitTOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970 - 479 -2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
SPRINKLER PERMIT
Job Address: 1000 LIONS RIDGE LP VAIL
Location.....: HOT TUB/POOL AREA, VAIL RUN
Parcel No...: 210312105006
Project No ` cxlU — p 1 Zq
OWNER VAIL RUN RESORT COMMUNITY AS 10/26/2010
1000 LIONS RIDGE LOOP
VAIL
CO 81657
APPLICANT WESTERN STATES FIRE PROTECTI 10/26/2010
7026 S TUCSON WAY
ENGLEWOOD
CO 80112
License: 338 -S
CONTRACTOR WESTERN STATES FIRE PROTECTI 10/26/2010
7026 S TUCSON WAY
ENGLEWOOD
CO 80112
License: 338 -S
Permit #: F10 -0088
Status ...: ISSUED
Applied..: 10/26/2010
Issued . .. 10/27/2010
Expires. .:
Phone: 303 - 792 -0022
Phone: 303 - 792 -0022
Desciption: REPAIR EXISTING SPRINKLER SYSTEM DUE TO NEW ROOF STRUCTURE.
Valuation: $3,600.00
*********#****}***} fss##s###s###+*#** + * * # * * # * # * + +# * * * * * * * * * * * * * * * * ** FEE SUMMARY +}}s}+ f} f*+s*+#**}##+#**#**** f + *# * # *# * + * * * * * * * * * * * * * * * * * * * }}
Mechanical - ->
$0.00 Restuarant Plan Review —>
$0.00 Total Calculated Fees - ->
$585.00
Plan Check --- >
$432.00 DRB Fee ---- — --- — -------- —>
$0.00 Additional Fees--- - - - - ->
$0.00
Investigation ->
$0.00 TOTAL FEES--------- - - - - ->
$585.00 Total Permit Fee ---------- >
$585.00
Will Call - --->
$0.00
Payments ------------------- >
$585.00
BALANCE DUE --------- >
$0.00
Item: 05100 BUILDING DEPARTMENT
Item: 05600 FIRE
DEPARTMENT
10/26/2010
mcgee Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 53
(FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA
13 (2007) and VFES Standards.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252
FROM 8:00 AM - 5 PM. it
SIGNATUREIF WNER OR VONPACTOR FOR HIMSELF AND OWNER
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO
Statement
*************************************************************
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number:
R100001703 Amount: $585.00 10/27/201010:09
AM
Payment Method:
Check Init: LC
Notation:
#120581 /
WESTERN STATES FIRE
PROTECTION
-----------------------------------------------------------------------------
Permit No:
F10 -0088 Type: SPRINKLER PERMIT
Parcel No:
2103 -121- 0500 -6
Site Address:
1000 LIONS RIDGE LP VAIL
Location:
HOT TUB /POOL AREA, VAIL RUN
Total Fees:
$585.00
This Payment:
$585.00 Total ALL Pmts:
$585.00
Balance:
$0.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code
--------------
Description Current Pmts
- - -
BP 00100003111100
- -- ------------------------ - - - - -- ------
SPRINKLER PERMIT FEES
- - - - --
153.00
PF 00100003112300
-----------------------------------------------------------------------
PLAN CHECK FEES
432.00
- - - - --
c
Department of Community Development
75 South Frontage Road
;�•. Vail, Colorado 81657
Tel: 970 -479 -2128
Fax: 970 - 479 -2452
Web: www.vailgov.com
^- e�elopmen Re ie C r 'n t
,. > :°
Ow
FIRE SPRINKLER PERMIT
Commercial & Residential Fire Alarm shop drawings are required at the time of
application submittal and must include the following information:
1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp
2. Equipment cut sheets of materials
3. Hydraulic calculations
4. A State of Colorado contractor registration number
5. Plans must be submitted by a Registered Fire Protection Contractor
Project Street Address:
1000 LIONS RIDGE LOOP
(Number) (Street)
Building /Complex Name: VAIL RUN SPA/POOL
Contractor Information:
Companv: Western States Fire Protection
(Suite #)
Company Address: 7026 S. Tuscan Way
City: Centennial State: CO
Contact Name: Joe Hayden
Contact Phone: 303 - 549 -8979
E -Mail joe.hayden @wsfp.us
80112
Town of Vail Contractor Registration No.: 338 -S
X -
Contractor Signature (required)
Property Information
Parcel #: 210312105006
(For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or
visit www.eaglecounty.us /patie)
Tenant Name: VAIL RUN RESORT
Owner Name: VAIL RUN RESORT COMMUNITY
Complete Valuation for Fire Sprinkler Permit:
Fire Sprinkler $: $3,600
Office Use:
Project #:
Building Permit #: L � `D ~ 0055
Sprinkler Permit #: / � ll 00 9 03
Lot #: Block # Subdivision:
Detailed Description of Work: REPAIR EXISTING
SPRINKLER SYSTEM DUE TO NEW ROOF
STRUCTURE
(use additional sheet if necessary)
Detailed Location of Work: Work will be preformed in
area
Does a Monitored Fire Alarm Exist? Yes ( ,,) No ( )
Does a Sprinkler System Exist? Yes(. No( )
Work Class:
New ( ) Addition ( ) Remodel ( ) Repair (v )
Retro -Fit ( ) Other( )
Type of Building:
Single- Family ( ) Duplex ( ) Multi - Family ( )
Commercial Restaurant ( ) Other ( )
Date Received:
TOWN OF VAIL
I�( OCT 25 2010 Ul
01- Feb -10
I///\ Western States
v Fire Protection Co.
RLOt;ctu� Ziuee "d �aa
Material Submittal
FOR
VAIL RUN SPA /POOL
1000 LIONS RIDGE LOOP
VAIL, CO 81657
Tenant Remodel
Prepared by:
Jeff Hagan
Project Manager
Western States Fire Protection Co.
7026 S. Tucson Way
Centennial, CO 80112
Phone (303) 792 -0022
Fax (303) 792 -9049
Cell (303 -549 -9553
Email jeff.hagan @wsfp.us
WSFP #CS0997
October 24, 2010
MATERIAL INDEX
VII. Grooved Fittings
A.
Description
Model
Manufacturer
I.
Sprinkler Heads
Style 005
Victaulic
C.
A. Standard Spray Quick Response Upright Sprinkler
F1FR -R3625
Reliable
D.
B. Standard Spray Quick Response Semi - Recessed Pendant
F 1 FR -R3615
Reliable
III.
Pipe — 1 -1/2" and smaller threaded
A. Black Schedule 40 Pipe
ASTM A 795
Varies"
IV.
Pipe — 2" and larger grooved
A. Black Schedule 10 Pipe
ASTM A135
Varies"
V.
Cast Iron Fittings
Varies
Varies"
VI.
Pipe Hangers (Per NFPA 13)
A. All Thread Rod
Fig. 100
Tolco
B. Adjustable Ring Hanger
Fig. 200
Tolco
C. C -Clamp Top Beam w /Locknut
Fig. 68
Tolco
VII. Grooved Fittings
A.
Grooved Firelock Fittings
Varies
Victaulic
B.
Grooved Firelock Rigid Couplings
Style 005
Victaulic
C.
Mechanical T, Bolted Branch Outlet
Style 920/922
Victaulic
D.
Grooved Concentric Reducer
Style 50/51
Victaulic
"Because of the current escalation occurring with steel, WSFP reserves the right to substitute pipe as required to meet
project schedules.
Reli
Bulletin 136 Rev.M
Model F1 FR
Model F1 FR Recessed
Quick Response
Sprinklers
Model F1 FR Sprinkler Types
S tandard pright
— 5' an ar en enT
Conventional
Vertical Sidewall
Horizontal Sidewall
- HSW 1 Deflector
odel F1 FR Recessed Sprinkler Ty pes
Recessed Pendent
Hecessed Horizontal I ewa
- HSW 1 Deflector
Listings & Approvals
1. Listed by Underwriters Laboratories, Inc. (UL)
2. Listed by Underwriters' Laboratories of Canada (ULC)
3. Certified by FM Approvals
4. Loss Prevention Council (LPC, UK)
5. NYC BS&A No. 587 -75 -SA
6. Meets MIL- S -901C and MIL -STD 167 -1
7. Verband der Schadenversicherer (VdS, Germany)
8. NYC MEA 258 -93 -E
UL Listing Category
Sprinklers, Automatic & Open
Quick Response Sprinkler
UL Guide Number
VNIV
Patents: US Patent No. 6,374,920 Applies to
Model F1 FR Vertical Sidewall Sprinklers.
Product Description
Reliable Models F1 FR and F1 FR Recessed Sprinklers are
quick response sprinklers which combine the durability of a
standard sprinkler with the attractive low profile of a decorative
sprinkler.
The Models F1 FR and F1 FR Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers have
demonstrated response times in laboratory tests which are
five to ten times faster than standard response sprinklers. This
quick response enables the Model F1 FR and F1 FR Recessed
sprinklers to apply water to a fire much faster than standard
sprinklers of the same temperature rating.
The glass bulb consists of an accurately controlled amount
of special fluid hermetically sealed inside a precisely manu-
factured glass capsule. This glass bulb is specially con-
structed to provide fast thermal response. The balance of
parts are made of brass, copper and beryllium nickel.
At normal temperatures, the glass bulb contains the fluid
in both the liquid and vapor phases. The vapor phase can
be seen as a small bubble. As heat is applied, the liquid ex-
Z3
C0
x-
W
30
CR
r
Recessed Pendent
(Model FP Shown)
pands, forcing the bubble smaller and smaller as the liquid
pressure increases. Continued heating forces the liquid to
push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distrib-
ute the discharging water.
Application
Quick response sprinklers are used in fixed fire protec-
tion systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector
style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Asso-
ciation or the approving Authority Having Jurisdiction.
Quick response sprinklers are intended for installation as
specified in NFPA 13. Quick response sprinklers and stan-
dard response sprinklers should not be intermixed.
The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552
Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers
Installation Wrench: Model D Sprinkler
Installation Data:
Sprinkler Type
Standard - Upright (SSU) and Pendent (SSP)
Deflectors Marked to Indicate Position
K Factor
Sprinkler
p
Height
Approval
APP
Organization
Sprinkler Identification
Number SIN
Us
Metric
__,
SSU
SSP
15mm Standard Orifice with " NPT R,ti" Thread
5.6
80
2.2" 56mm
1,2,3,4,5,6,7
R3625
R3615
2 0mm) Large Orifice with 4 NPT ( R 3 /, )Thread
8.0
115
2.3" 58mm
1,2,3,4,7,8
R3622
R3612
" 17mm Small Orifice with y" NPT Ri) Thread
4.2
60
2.2" 56mm
1,2,8
R3623
R3613
10mm Small Orifice with , "NPT R,; Thread
2.8
40
2.2" 56mm
1,2,8
R3621
R3611
10mm Orifice XLH with R'/8 " Thread
4.2
60
56mm
4,6,7
R3624
R3614
Conventional-Install in Upright or Pendent Position
4.2
5.6
8.0
60
80
115
56mm
56mm
58mm
4,6,7
4,7
R3674
R3675
R3672
10mm Orifice XLH with R Thread
15mm Standard Orifice with }z' NPT (Ry) Thread
20mm Large Orifice with 3 /;' NPT (R )Thread
Model F1 FR Quick Response Recessed Pendent Sprinkler
Installation Wrench: Model GFR1 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor
Sprinkler
Height
Approval
Organizations
Sprinkler Identification
Number (SIN)
US
Metric
1 2 ' (15mm)
12 " NPT (R
5.6
80
2.2'(56mm)
1,2,3,4,5,7,8
R3615
32 (20mm);'
NPT (R /,)
8.0
115
2.3" (58mm)
1,2,3,8
R3612
;s' (11 mm)
1z" NPT (R'/2)
4.2
60
2.2" (56mm)
1,2,8
R3613
?B' (10mm)
Jz " NPT (R' /2)
2.8
40
2.2'(56mm)
1,2,8
R3611
10mm
we
4.2
60
56mm
4,7
R3614
(') Refer to escutcheon data table for approvals and dimensions.
1 /8
(l7 I
z 172 2IF a s ` t
In.r—/ '1 rxrOUr E
1 WER IIJ F/ t E2 ESCO-Wr[w 00A TA" MR 4RFROV44S AND Dwrl 50iS.
1 5 /6" Do. (66.7mj - --
I40" MI MAC
? S, /r6' DM, [58.7mm]
Can
F12' R£DUCCR
�-- _ _ - _ _ _ 1 I " .r
1
Q V - FACt Ur F,7TING
TO FAC£ OF CFILINC
DWFN501
M
ADJUSTMENT
(!) RLFLR TO rF LSCaTCI IWA MULL rOR A,PRCNAL5 AN✓ DMLN59 5
2.
C
S 1,/4' "Ott D!A
_— jSLrm+iJ
(ag r�l
I � X ! /r' RFDCk;FF
UvT4 "!(IfT
„ Grri SRau.nrn
?'AA-N BO55
i
I
1
1 /8
(l7 I
z 172 2IF a s ` t
In.r—/ '1 rxrOUr E
1 WER IIJ F/ t E2 ESCO-Wr[w 00A TA" MR 4RFROV44S AND Dwrl 50iS.
1 5 /6" Do. (66.7mj - --
I40" MI MAC
? S, /r6' DM, [58.7mm]
Can
F12' R£DUCCR
�-- _ _ - _ _ _ 1 I " .r
1
Q V - FACt Ur F,7TING
TO FAC£ OF CFILINC
DWFN501
M
ADJUSTMENT
(!) RLFLR TO rF LSCaTCI IWA MULL rOR A,PRCNAL5 AN✓ DMLN59 5
2.
C
Installation
Quick response sprinklers are intended for installation as
specified in NFPA 13. Quick response sprinklers and stan-
dard response sprinklers should not be intermixed.
The Model F1 FR Recessed Quick Response Sprinklers are to
be installed as shown. The Model F1 or F2 Escutcheons illus-
trated are the only recessed escutcheons to be used with the
Model F1 FR Sprinklers. The use of any other recessed escutch-
eon Will void all approvals and negate all warranties.
When installing Model F1 FR Sprinklers, use the Model D Sprin-
kler Wrench. When installing Model F1 FR Recessed Pendent or
Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any
other type of wrench may damage these sprinklers.
Glass bulb sprinklers have orange bulb protectors to minimize
bulb damage during shipping, handling and installation. RE-
MOVE THIS PROTECTION AT THE TIME THE SPRINKLER
SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re-
moval of the protectors before this time may leave the bulb vul-
nerable to damage. RASCO wrenches are designed to install
sprinklers when covers are in place. REMOVE PROTECTORS
BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS
TO REMOVE THE PROTECTORS.
Temperature Ratings
Classification
Sprinkler
Tem erature
Max. Ambient
Bulb
peon Approvals
Temp.
Color
°C
j °F
Ordinar
Sprinkler
Wall Dimension
Bright Brass
Bright Brass
1 1
Black Plated
Black Paint
F1
1,2,4,8
Iritermeolale
(38.1mm)
11b
1507
M6
-- 7ellow
Intermediate
(5mm -24mm)
19.1mm
reen
High (t) 141 286 225 °F (107 °C) Blue
Not available for recessed sprinklers.
Escutcheon Data
ES
Sprinkler
Escutch
Face of Fitting
peon Approvals
Adjustment
Chrome Plated (3)
to Ceiling or
White Painted (3)
Special Application Finishes
Sprinkler
Wall Dimension
Bright Brass
Bright Brass
Black Plated
Black Plated
Black Paint
F1
1,2,4,8
Max Recess
(38.1mm)
'a° '3;8'
Min Recess
%"
(5mm -24mm)
19.1mm
1y"
F2
1,2,3,4,5,7,8
Max Recess
(38.1mm)
38" 'Ye"
Min Recess
'% fi
(5mm -17mm)
24mm
FP
1,2
_
Max Recessed
is
1y" (38.1mm)
11
PushoN
Thread -off
1,2
Min Recessed
1 "(25.4mm)
24mem
No Dimensional Figure for FP
Maintenance
The Models F1 FR and F1 FR Recessed Sprinklers
should be inspected quarterly and the sprinkler system
maintained in accordance with NFPA 25. Do not clean
sprinklers with soap and water, ammonia or any other
cleaning fluids. Remove dust by using a soft brush or gen-
tle vacuuming. Remove any sprinkler which has been
painted (other than factory applied) or damaged in any
way. A stock of spare sprinklers should be maintained to
allow quick replacement of damaged or operated sprin-
klers. Prior to installation, sprinklers should be maintained
in the original cartons and packaging until used to mini-
mize the potential for damage to sprinklers that would
cause improper operation or non - operation.
Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Sidewall (Vertical, Horizontal HSW1)
Recessed Pendent
Recessed Horizontal Sidewall HSW1
Finishe t "
Sta Finishes
Sprinkler
Escutch
Bronze
Brass
Chrome Plated
Chrome Plated (3)
White Polyester Coated
White Painted (3)
Special Application Finishes
Sprinkler
Escutcheon
Bright Brass
Bright Brass
Black Plated
Black Plated
Black Paint
Black Paint
Off White
Off White
Satin Chrome
Satin Chrome
( Other finishes and colors are available on special order.
Consult the factory for details.
( FM Approvals is limited to bronze and brass, chrome or black
plated finishes only.
(3) FP Push- on/rh read -off escutcheon
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
6. Sprinkler Finish
7. Escutcheon Type
8. Escutcheon Finish (where applicable)
Note: When Model F1 FR Recessed sprinklers are
ordered, the sprinklers and escutcheons are packaged
separately.
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research
Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property forover 80years, and are installed and serviced by the most highly qualified and reputa-
ble sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc.
(800)431 -1588 Sales Offices
(800)848-6051 Sales Fax
(914)668-3470 Corporate Offices
www.reliablesprinkler.com Internet Address
0 Recycled
Paper
Revision lines indicate updated or new data
EG. Printed in U.S.A. 7/05 P/N9999970027
Component of State of
California OSHPD Approved C & USTED
Seismic Restraints System
Fig. 100 -All Thread Rod Full Lengths
Size Range — Secures 3/8" thru 7/8" rod in
10' lengths
Material — Carbon Steel
Maximum Temperature — 750 °F
Finish — Plain
Note — Available in Electro- Galvanized and
HDG finish or Stainless Steel materials.
Order By — Figure number, rod diameter
and finish
Dimensions - Weights
Max Rec. Load Lbs.
Rod For Service Temps Approx.
Size 650 °F 750 °F Wt. /100
1/4
240
215
12
610
540
1
1130
101
5
5/8
1810
1610
84
3/4
2710
2420
123
7/8
3770
3360
169
1
4960
4420
222
1 1 /4
8000
7140
360
1
11630
10370
510
® OFFICE/MANUFACTURING FACILITY - 1375 SAMPSON AVE, - CORONA, CA 92879 - PH: 951.737.5599 - FAX: 951.737.0330
CUSTOMER SERVICE - 800.786.5266
wwwlo/co'com
Fig. 200 - "Trimline" Adjustable Band Hanger C & OS LISTED
Size Range — 1/2" thru 8" pipe
Material — Carbon Steel, Mil. Galvanized to G90
specifications
Function — For fire sprinkler and other general piping
purposes. Knurled swivel nut design permits hanger
adjustment after installation.
Features —
• (1/2" thru 2 ") Flared edges ease installation for
all pipe types and protect CPVC plastic pipe from
abrasion. Captured design keeps adjusting nut
from separating with hanger. Hanger is easily
installed around pipe.
• (2 thru 8" Spring tension on nut holds it
securely in hanger before installation. Adjusting
nut is easily removed.
Approvals — Underwriters' Laboratories listed (1/2"
thru 8 ") in the USA (UL) and Canada (cUL) for steel
and CPVC plastic pipe and Factory Mutual Engineering
Approved (3/4" thru 8 "). Conforms to Federal
Specifications WW -H -171 E, Type 10 and Manufacturers
Standardization Society SP -69, Type 10.
Maximum Temperature — 650 °F
Finish — Mil. Galvanized. For Stainless Steel materi-
als, order TOLCOW Fig. 200WON.
Order By — Figure number and pipe size
2 1/2 THRU 8 INCH PIPE
Dimensions • Weights
Pipe Rod Size Max. Rec. Approx.
Size Inch Metric A B Load Lbs. Length
1/2 3/8 8mm or 10mm 3� 2 400 11
3/4
3/8
8mm or 10mm
318
2
400
11
1
3/8
8mm or 1 Omm
3H
2%
400
12
1 1 /4
1 �h
2
3/8
3/8
3/8
8mm or 10mm
8mm or 10mm
8mm or 10mm
3Y4
3
4
2
2
3
400
400
400
13
14
15
2h
3
3/8
3/8
10mm
10mm
5Y8
5
4t'A
4
600
600
27
29
mm
a
600
34
4
3/8
10mm
71/8
5
1000
35
5
1/2
12mm
9/a
6Ya
1250
66
6
1/2
12mm
101/8
6
1250
73
8
1/2
12mm
13
8
1250
136
OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330
CUSTOMER SERVICE • 800.786.5266
www.tolco.com
Jj
Fig. 68 - Wide Throat Top Beam "C" Clamp w /Locknut
Size Range — 3/8" thru 3/4" rod
Function — For attachment to structural shapes requiring
wider throat especially under roof with bar joist construction.
This clamp may be used in the set screw down position only.
Approvals — Conforms to Federal Specification
WW -H -171 E, Type 23 and Manufacturers Standardization
Society SP -69, Type 19.
Finish — Plain
Note — Available in Electro- Galvanized finish.
Order By — Figure number, rod size and finish
Note — Do not over tighten set screw.
Dimensions • Weights
Rod
Max. Rec.
Approx.
Size
Load Lbs.
WtJ100
3/8
400
34
1/2
500
50
5/8
600
53
3/4
800
86
LV
y i
® OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951 737.0330
CUSTOMER SERVICE • 800.786.5266
www.tolco.com
10.03
FireLock® Fittings
PRODUCT DESCRIPTION
VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY
FireLock® products comprise a unique system specifically designed for fire protection services. FireLock
full -flow elbows and tees are a CAD - developed, hydrodynamic design that has a shorter center -to -end
dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain
similar flow characteristics as standard full flow fittings.
FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of
other couplings or flange adapters may result in bolt pad interference.
Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005
couplings.
Patented
FM
See Victaulic
publication 10.01
for details.
DIMENSIONS
I. to E�
ctoE�
a � °
c ✓ °
to E
L o0
No. 001 No. 003
c
�toE�
No. 001
No. 003
No. 002
No. 006
C
olo E to
E
T
- t
No. 002
No. 006
e REGISTERED TRADEMARK OF VICTAUUC - O COPYRIGHT 2006 VICTAUUC - PRINTED IN U.S.A. - SKU NWCAS- 67PJUx
United States • Phone: 1 - 800 - PICK -VIC (1- 800 - 742 -5842) • Fax: 610 - 250 -8817 • e -mail: pickvic @victaulic.com
Canada • Phone: 905 -884 -7444 • Fax: 905- 884 -9774 • e -mail: viecanada@victaulic.com
Europe • Phone: 32 -9- 381 -1500 • Fax: 32-9-380-4438 • e -mail: viceuro@victaulic.be
UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e -mail: viceuro@Victaulic.be
Central and South America • Phone: 610- 559 -3300 • Fax: 610 -559 -3608 • e -mail: vical@victaulic.com
Australasia • Phone: 86- 21- 54253300 • Fax: 86-21-54253671 • e -mail: vicap@viclaulic.com
1539 REV F
1�'tic�U'I�i®
No. 001
No. 003
No. 002
No. 006
Fitting Size
90° Elbow
45° Elbow
Straight Tee
Cap
Actual
Aprx.
Aprx.
Aprx.
Thickness
Aprx.
Nominal
Outside
C to E
Weight
C to E
Weight
C to E
Weight
r
Weight
Diameter
Diameter
Inches
Each
Inches
Each
Inches
Each
Inches
Each
Inches/mm
Inches/mm
mm
LbsJkg
mm
LbsJkg
mm
LbsJkg
mm
LbsJkg
11 14
1.660
-
-
-
-
-
-
0.82
0.3
32
42.4
-
-
-
-
-
-
21
0.1
1
1.900
2.75
1.2
1.75
0.9
2.75
2.0
0.82
0.4
40
48.3
70
0.5
45
4.1
1 70
0.9
21
02
2
2.375
2.75
1.7
2.00
1.8
1 2.75
2.4
0.88
0.6
50
60,3
70
0.8
51
0.8
70
1.1
22
0.3
2
2.875
3.00
3.1
2.25
2.2
3.00
3.6
0.88
1.0
65
73.0
76
1.4
57
1.0
76
1.6
22
0.5
76.1 mm
3.000
3.00
3.30
2.25
2.4
-
-
-
-
76.1
76
1.5
57
1.1
-
- I
-
-
3
3.500
3.38
4.0
2.50
3.1
3.38
5.3
0.88
1.2
80
88.9
86
1.8
64
1.4
86
2.4
22
0.5
e REGISTERED TRADEMARK OF VICTAUUC - O COPYRIGHT 2006 VICTAUUC - PRINTED IN U.S.A. - SKU NWCAS- 67PJUx
United States • Phone: 1 - 800 - PICK -VIC (1- 800 - 742 -5842) • Fax: 610 - 250 -8817 • e -mail: pickvic @victaulic.com
Canada • Phone: 905 -884 -7444 • Fax: 905- 884 -9774 • e -mail: viecanada@victaulic.com
Europe • Phone: 32 -9- 381 -1500 • Fax: 32-9-380-4438 • e -mail: viceuro@victaulic.be
UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e -mail: viceuro@Victaulic.be
Central and South America • Phone: 610- 559 -3300 • Fax: 610 -559 -3608 • e -mail: vical@victaulic.com
Australasia • Phone: 86- 21- 54253300 • Fax: 86-21-54253671 • e -mail: vicap@viclaulic.com
1539 REV F
1�'tic�U'I�i®
10.03
FLOW DATA
MATERIAL SPECIFICATIONS
Fitting: Ductile iron conforming to ASTM A -536, grade 65 -45 -12
Fitting Coating: Orange enamel
• Optional: Hot dipped galvanized
This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
FireLock® Fittings
Frictional Resistance
Fitting Size
Equivalent FeeUmeters of Straight Pipe
Actual
Straight Tee
Nominal
Outside
No. 002
Diameter
Diameter
90° Elbow
45° Elbow
Inches/mm
Inches/mm
No. 001
No. 003
Branch
Run
1 1 /4
1.660
1.5
0.8
33
1.5
32
42.4
0.5
0.2
1.1
0.5
1 1 /2
1.900
2.2
1.1
5.5
2.2
40
48.3
0.7
0.3
1.7
0.7
2
2.375
3.5
1.8
8.5
3.5
50
60.3
1.1
0.5
2.6
1.1
2 1 / 2
2.875
4.3
2.2
10.8
4.3
65
73.0
1.3
0.7
3.3
13
76.1 mm
3.000
4.5
2.3
11.0
4.5
76.1
1 1.4
0.7
3.4
1.4
3
3.500
5.0
2.6
13.0
5.0
80 1
88.9
1 1.5
0.8
4.0
1 5
MATERIAL SPECIFICATIONS
Fitting: Ductile iron conforming to ASTM A -536, grade 65 -45 -12
Fitting Coating: Orange enamel
• Optional: Hot dipped galvanized
This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
FireLock® Fittings
�ctaulic°
An ® 9001 certified company
Vic INUq
Gasket System
PRODUCT DESCRIPTION
FireLockTM Style 005 rigid
coupling has a unique, pat-
ented angle -pad design
which allows the housings
to offset while clamping the
grooves. By permitting the
housings to slide on the
angled bolt pads, rigidity is
obtained.
Patented
DIMENSIONS
Rated for wet and dry sprinkler
systems at 350 PSI (2413 kPa) for
1 - 4 (42,4 - 114,3 mm) sizes
and 300 PSI (2068 kPa) for 4 -
8' (108,0 - 219,1 mm) sizes;
Schedule 10 roll grooved or
Schedule 40 cut or roll grooved
steel pipe. Style 005 is rigid and
does not accommodate expan-
sion, contraction or angular
deflection.
The FireLock couplings
provide rigidity for valve
connections, fire mains and
long straight runs. Support
and hanging requirements
correspond to NFPA 13
Style 005
FireLock "
Rigid Coupling
with Vic -Plus- Gasket System
Sprinkler Systems. Angle -
pad design permits assem-
bly by removing one nut/
bolt and swinging the
housing over the gasket.
This reduces components
to handle during assembly;
speeds and eases installa-
tion on pipe grooved to
Victaulic specifications.
Style 005 FireLock cou-
plings with the Vic -
Plus' Gasket System
are designed and rec-
ommended for use
§ LPC and VdS Approved,
see notes on page 2.
ONLY on fire protection
systems.
Vic -Plus Gasket System:
Victaulic now offers a gas-
ket system which requires
no field lubrication. The
Vic- Plus System (patent
pending) is dry, clean, and
non -toxic. It reduces
assembly time substantially
and eliminates the mess
and chance of
over - lubrication.
10.02 -10
SIZE
Max.
Max.
Allow.
Dimensions
Nominal
Work.
End
Pipe End
@ Bolt/Nut
Inches
Aprx.
Inches
Press. §
Load
Sep. t
No. - Size
Wgt. Ea.
Acnea3 mr,
PSI' /kP n
Lbs.' /rt
In. /mm
Inches /mm
X
Y
Z
Lbs. /Kg
1 1 /4
350
755
0.05
2.75
4.50
1.88
1.2
2 - X 2
1'h
350
990
0.05
2 - 3 /e X 2
3.00
4.75
1.88
1.2
2
350
1550
0.07
3.50
5.25
1.88
1.6
2-% X 21h
2
350
2270
0.07
2 - 3 /4 X 2
4.00
5.75
1.88
1.9
76,1 mm
350
2475
0.07
2- 3 AX2'h
4.13
5.75
1.88
1.9
3
350
3365
0 07
2 3 /e X 2'h
41.63
6 13
1.88
2.1
- ® § t Refer to notes on page 2.
Victaulic World Headquarters • P.O. Box 31, Easton, PA 18044 -0031 •4901 Kesslersville Rd., Easton, PA 18040.1 -800 -PICK VIC • FAX: 610/250 -8817 • www.victatilic.com
1538 Rev.E 10100 ® Registered Trademark of Victaulic ® Copyright 1999 Victaulic Printed in U.S.A.
MATERIAL SPECIFICATIONS
Housing: Ductile iron conform-
ing to ASTM A -395, grade 65-
45-15, and ASTM A -536, grade
65- 45 -12.
Housing Coating: Orange
enamel
❑ Optional: Hot dipped galva-
nized
Gasket:
❑ Grade "E" EPDM - Type A
Vic -Plus Gasket System t
(Violet color code). FireLock
products have been Listed by
Underwriters Laboratories
Inc. and Approved by Factory
Mutual Research for wet and
dry (oil free air) sprinkler ser-
vices up to the rated working
pressure using the Grade "E"
Type A Vic -Plus Gasket
System, requiring no field
lubrication.
For dry services, Victaulic
continues to recommend the
use of Grade "E" Type A
FlushSeal Vic -Plus Gasket
System. Contact Victaulic for
details.
Bolts/Nuts: Heat treated car-
bon steel, zinc electroplated to
ASTM B -633; Track head bolt
conforming to ASTM A -183
minimum tensile 110,000 PSI
(758340 kPa); Flanged hex nut
conforming to ASTM A -563,
Grade A.
t Standard gasket and FlushSeal gasket
approved for dry pipe systems to -40 °F
(- 40 °C). Supplemental lubricant is rec-
ommended for services installed at or
continuously operating below 0 °F
(- 18 °C). Victaulic continues to recom-
mend the use of FlushSeal gaskets for
dry services.
The information provided below is based on the latest listing and approval data at the time of publication.
Listings /Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for
performance on other pipe and the latest listings and approvals.
10.02 -zA
Rated Working Pressure
Rated Working Pressure
Pipe
Schedule
Size
Inches
UL
ULC
FM
Pipe
Schedule
Size
Inches
UL
ULC
FM
5
1
175
175
175
EZ
4
300
300
300
10,40
1
350
350
350
6
175
175
175
5-8
300
300
300
SF
1
300
300
300
BLT
1
300
300
300
Super 40
1
300
300
300
DF
1
300
300
300
TL
1
300
300
300
6
175
175
175
WLS
1
300
300
300
DT
1
300
300
300
XL/XL -II
1
300
300
300
EL
1
300
300
300
NOTES:
5 refers to Listed/Approved
Schedule 5 steel sprinkler pipe.
10 refers to Listed /Approved
Schedule 10 steel sprinkler pipe.
40 refers to Listed/Approved
Schedule 40 steel sprinkler pipe.
BLT refers to Listed/Approved
steel sprinkler pipe manufactured
by American Tube Company.
DF refers to Listed/Approved
Dyna -Flow steel sprinkler pipe
manufactured by American Tube
Company.
DT refers to Listed/Approved Dyna
Thread steel sprinkler pipe
manufactured by American Tube
Company.
EL refers to Listed/Approved
Eddylite steel sprinkler pipe
manufactured by Bull Moose Tube
Co.
EZ refers to Listed/Approved
EZ -Flow steel sprinkler pipe
manufactured by Northwest Pipe
& Casing Co.
SF refers to Listed/Approved
Super -Flo steel sprinkler pipe
manufactured by Allied Tube and
Conduit Corporation.
SL refers to Listed/Approved steel
sprinkler pipe manufactured by
Western Tube and Conduit
Corporation.
Super 40/XL refers to Listed/
Approved Super 40 or Super XL
steel sprinkler pipe manufactured
by Allied Tube and Conduit
Corporation.
WLS refers to Listed/Approved
steel sprinkler pipe manufactured
by Wheatland Tube Company.
XL/XL -II refers to Listed/Approved
XL or XL -II steel sprinkler pipe
manufactured by Allied Tube and
Conduit Corporation.
NOTES
Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accor-
dance with Victaulic specifications. Contact Victaulic for performance on other pipe.
WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1 /2 times the figures shown.
t For field installation only. FireLock Style 005 couplings are essentially rigid and do not accommodate expansion /contraction.
Number of bolts required equals number of housing segments.
Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details.
§ Style 005 couplings are VdS and LPC Approved to 12 Bar (175 PSI).
WARNING: Piping systems must always be depressurized and drained before attempting disassembly and removal of any Victaulic piping products.
This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic installation /assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
10.90-2
Mechanicakr
STYLES 920 AND 920N
STYLES 920 AND 920N
Victaulic Mechanical -T Outlet provides a direct branch connection at any location a hole can
be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures
the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D.
Cross -type connections can be achieved by utilizing two upper housings of the same style and
size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N
housings cannot be mated to achieve a cross connection.
Style 920 and Style 920N Mechanical -T outlets are available with grooved or female threaded
outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous-
ings are available, supplied with plated bolts.
All sizes of Style 920 and 920N are rated at 500psi /345OkPa working pressure on Schedule
10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly -
butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact
Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on
PVC plastic pipe.
Standard piping practices dictate that the Mechanical -T Styles 920 and 920N must be
installed so that the main and branch connections are a true 90° angle when permanently
attached to the pipeline surface.
STYLE 920 CROSS
PATENTED
MATERIAL SPECIFICATIONS Housing /Coating: Ductile iron conforming to ASTM A -536, grade 65- 45 -12, with orange enamel
coating. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special
request.
• Optional: Hot dipped galvanized
JOB OWNER
System No.
Gasket: (Specify choice *)
• Grade "E" EPDM
EPDM (Green color code). Temperature range -30 °F to +230 °F / -34 °C to +110 °C.
Recommended for cold and hot water service within the specified temperature range plus a
variety of dilute acids, oil -free air and many chemical services. UL Classified in accordance
with ANSI /NSF 61 for cold +86 °F / +30 °C and hot +180 °F / +82 °C. NOT RECOMMENDED FOR
PETROLEUM SERVICES.
• Grade "T" nitrile
Nitrile (Orange color code). Temperature range -20 °F to +180 °F / -29 °C to +82 °C.
Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the
specified temperature range. Not recommended for hot water services over +150 °F / +66 °C or
for hot dry air over +140 °F / +60 °C.
'Services listed are General Service Recommendations only. It should be noted that there are
services for which these gaskets are not recommended. Reference should always be made to
the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a
listing of services which are not recommended.
Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical
requirements of ASTM A -449 and physical requirements of ASTM A -183.
CONTRACTOR
Submitted By
Date
Location
ENGINEER
Spec Sect Para
Approved
Date
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
REV -1
✓ ctsulid
11.02_1
IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS
Mechanical -r Bolted Branch Outlets
STYLES 920 AND 920N
11.02
U FM ULC Vds �l
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLES 920 AND 920N
DIMENSIONS
4
STYLE 920 CROSS
PATENTED
Y Z tliYa• . _ MIM MM
2 x %2 (a) 920N 500 0 1.50 2.00 2.53 1.61 5.35 2.75 3.1
V 50 15 3450 38.1 51 64 41 136 70 1.5
(a) j 920N 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 _
i 20 3450 38.1 50 64 41 136 70 1.5
I (a) 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 _
/ W 25 920N 3450 38.1 47 64 41 136 70 1.4
1 '/4 (a) t 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2
GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5
1 1 12 (a) t 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2
40 3450 44.5 52 70 79 41 136 83 1.7 1.5
v r - Z
V /
T IR
FEMALE THREADED OUTLET
IMPORTANT NOTES: TABLE CONTINUED ON PG. 3
Style 920 and Style 920N housings cannot be
mated to one another
to achieve cross connections.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. X . A
11.02._2 REV
76.1 x Vz (a) 920
300
1.50
2.22
2.75
_
2.25
6.46
3.18
3.9
15
2065
38.1
56
70
57
164
81
1.8
• Provides a direct branch connection at
' A (a)
300
1.50
2.19
2.75
2.25
6.46
3.18
3.9
any location where a hole can be cut
_20 920
2065
38.1
56
70
-
57
164
81
1.8
in the pipe
1 (a) 920
300
1.50
2.07
2.75
_
2.25
6.46
3.18
3.8
25
2065
38.1
53
70
57
164
81
1.7
• A pressure responsive gasket provides
1''A(a) 920
500
1.75
2.30
3.00
3.31
1.92
6.29
3.00
3.5
3.2
the seal
32
3450
44.5
58
76
84
49
160
76
1.6
1.5
1'h (a) 920
500
2.00
2.28
3.00
3.31
1.92
6.29
3.25
3.5
3.3
• Request Publication 11.03 for
40
3450
50.8
58
76
84
49
160
83
1.6
1.5
Mechanical -T cross assemblies
3 x ,h (a) 920N
500
1.50
2.52
3.05
_
2.28
6.15
2.75
3.4
_
80 15
3450
38.1
64
78
58
156
70
1.6
• Pressure rated up to 500 psi /3450 kPa
-% (a) 920N
500
1.50
2.49
3.05
-
2.28
6.15
2.75
34
_
on steel pipe; also available for use
20
3450
38.1
63
78
58
156
70
1.6
with HDPE pipe
1 (a) 920N
500
1.50
2.38
3.06
_
2.28
6.15
2.75
3.3
3450
38.1
61
78
58
156
70
1.6
• Sizes from 2 x 1 /2 750 x 15 mm
_
1 Ya (a) t) 1 920N
500
1.75
2.55
3.25
3.56
2.28
6.15
3.00
3.8
3.7
through 8 x 4 7200 x 100mm
32 (b 1
3450
44.5
65
83
90
58
156
76
1.8
1.8
h (a) i 920N
40 (b)
500
3450
2.00
50.8
2.78
71
3.50
89
3.56
90
2.28
6.15
3.25
4.1
3.8
- --- --
58
156
83
1.9
1.8
2 (a) 920N
500
2.50
2.75
3.50
3.56
2.28
6.75
3.88
4.9
4.6
50
3450
63.5
70
89
90
58
172
99
2.3
2.1
IMPORTANT NOTES: TABLE CONTINUED ON PG. 3
Style 920 and Style 920N housings cannot be
mated to one another
to achieve cross connections.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. X . A
11.02._2 REV
IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS
Mechanical -r Bolted Branch Outlets
STYLES 920 AND 920N
11.02
U FM > �( •�
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLES 920 AND 920N
DIMENSIONS
._ Ju
Irl
GROOVED OUTLET
Ivl
FEMALE THREADED OUTLET
• Provides a direct branch connection at
any location where a hole can be cut
in the pipe
• A pressure responsive gasket provides
the seal
• Request Publication 11.03 for
Mechanical -T cross assemblies
• Pressure rated up to 500 psi /3450kPa
on steel pipe; also available for use
with HDPE pipe
• Sizes from 2 x 1 h "/50 x 15 mm
through 8 x 47200 x 100mm
IMPORTANT NOTES:
Style 920 and Style 920N housings cannot be
mated to one another
to achieve cross connections.
4
STYLE 920 CROSS
PATENTE
" Center of run to engaged pipe end, female threaded outlet only (dimensions approximate).
t Available with grooved or female threaded outlet. Specify choice on order.
# Center of run to end of fitting.
# Female threaded outlets are available to NPT and BSPT specifications.
(a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order
(b) For 76.1 mm threaded outlet, specify 2 BSPT clearly on order.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. �1rit.'al.�
REV _1 11.02 .5
TABLE CONTINUED FROM PAGE 4
1
165.1 x
920
500
1.50
3.88
4.56
_
3.79
9.34
2.75
8.0
_
25
3450
38.1
99
116
96
237
70
3.6
1 A
920
500
1.75
4.43
5.13
_
3.79
9.34
3.25
8.4
_
32
3450
44.5
113
130
96
237
83
3.8
1'h (a) t
920
500
2.00
4.41
5.13
_
3.79
9.34
3.25
8.4
_
40
3450
50.8
112
130
96
237
83
3.8
2 (a) t
920
500
2.50
4.38
5.13
_
3.79
9.34
3.88
8.5
_
50
3450
63.5
111
130
96
237
99
3.9
2'h t
920
500
2.75
4.01
5.13
_
3.63
10.51
4.63
8.6
7.6
65
3450
69.9
110
130
92
267
118
3.9
3.4
76.1 mm
920
500
2.75
4.01
5.13
5.21
3.63
10.51
4.63
8.6
7.6
3450
69.9
110
130
132
92
267
118
3.9
3.4
3 (a) t
920
500
3.50
4.31
5.50
5.13
3.63
10.51
5.31
10.2
8.4
80
3450
88.9
110
140
130
92
267
135
4.6
3.8
4 (a) t
920
500
4.50
3.81
5.75
5.38
3.63
10.51
6.25
10.5
8.4
_ 100
3450
114.3
97
146
137
92
267
159
4.8
3.8
8 2 (a) t
x
920
S00
2.75
5.44
6.19
6.25
4.81
12.42
4.50
11.6
11.6
200 _ 50 _
3450
69.9
138
157
159
122
316
114
5.3
5.3
2'h (a) t
920
500
2.75
5.07
6.19
6.19
4.81
12.42
4.50
11.6
11.6
65
3450
69.9
129
157
157
122
316
114
5.3
5.3
76.1 mm
920
500
2.75
_
_
6.25
4.81
12.42
4.56
_
11.6
3450
69.9
159
122
316
116
5.3
3 (a) t
920
500
3.50
5.31
6.50
6.50
4.81
12.42
5.31
12.6
11.6
80
3450
88.9
135
165
165
122
316
135
5.7
5.3
4 (a) t
920
500
4.50
4.81
6.75
6.38
4.81
12.42
6.25
15.3
12.5
100
3450
114.3
122
171
162
122
316
159
6.9
5.7
" Center of run to engaged pipe end, female threaded outlet only (dimensions approximate).
t Available with grooved or female threaded outlet. Specify choice on order.
# Center of run to end of fitting.
# Female threaded outlets are available to NPT and BSPT specifications.
(a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order
(b) For 76.1 mm threaded outlet, specify 2 BSPT clearly on order.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. �1rit.'al.�
REV _1 11.02 .5
' IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02
Mechanical -T® Bolted Branch Outlets FM Vds ft
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLES 920 AND 920N
FLOW DATA
L1
Exaggerated for Clarity
54
STYLES 920 AND 920N STYLE 920 CROSS
PATENTED
Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 90ON
and 929 Mechanical -TI fittings can best be expressed in terms of the pressure difference across the
inlet and branch. The pressure difference can be obtained from the relationship below.
C Values
Values for flow of water at +60 °F / +16 °C are shown in the table below.
'fi
0.840
2.0
15
213
_
0.6
%
1.050
4.0
2
26.7
_
1.2
1
1.315
5.0
25
33.7
_
1.5
1 %
1.660
5.5 6.0
32 1
42.4
1.7 1.8
1 'V 1
1.900
7.0 8.0
40
48.3
2.1 2A
Formulas for C Values:
AP = Q Where:
C 22 Q = Flow (GPM)
AP = Pressure Drop (psi)
Q = C„ x JA C� = Flow Coefficient
2
2.375
9.0
10.5
50
60.3
2.7
3.2
2'fi
2.875
11.0
12.5
65
73.0
3.4
3.8
3
1500
13.5
15.5
80
88.9
4.1
4.7
4
4.500
20.0
22.0
100
114.3
61
6.7
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. iataulicr
11.02 6 REV I
• IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS
Mechanical -T® Bolted Branch Outlets
STYLES 920 AND 920N
APPROVED PRESSURE RATINGS
1 1.02
UL FM ULC VdS "
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLES 920 AND 920N STYLE 920 CROSS
PATENTED
The information provided below is based on the latest listing and approval data at the time of publi-
cation. Listings /Approvals are subject to change and /or additions by the approvals agencies. Contact
Victaulic for performance on other pipe and the latest listings and approvals.
21/2-6
2.875 - 6.625
All
10, 40
400
400
400
6 5-15 0
73.0- 168.3
2755
2755
2755
21/2-4
2.875 - 4.500
All
DF
300
300
300
65 - 100
73.0-114.3
2065
2065
2065
21/2-4
2.875 - 4.500
All
SF
300
300
300
65 -1
73.0 -114.3
2065
2065
2065
6
6.625
3,4
0
300
300
250
150
168.3
2065
2065
1724
6
6.625
3,4
30, 40
300
300
300
150
168.3
2065
2065
2065
2
2 /2
10, 40
2 00
_
—
200
625
8
8.625
3,4
10
300
_
250
2
219.1
2065
1724
8
8.625
3,4
30, 40
300
_
300
200
219.1
2065
2065
NOTES:
10 refers to Listed /Approved Schedule 10 steel sprinkler pipe.
40 refers to Listed /Approved Schedule 40 steel sprinkler pipe.
OF refers to Listed /Approved Dyna -Flow steel sprinkler pipe manufactured by American Tube Company
SF refers to Listed /Approved Super -Flo steel sprinkler pipe manufactured by Allied Tube and Conduit
Corporation.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. dtiit.'t
REV 1 11.02 7
10.52
Style 922 FireLock° Outlet -T
VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY
PRODUCT DESCRIPTION
DIMENSIONS
B � B IVI
Nominal Size
The Style 922 Outlet -T provides a convenient method of incorporating 1 12, 3 /4, and 1' (15, 20 and 25 mm)
outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products.
+
Available for 1 through 76,1 mm (32 to 76,1 mm) piping systems, Style 922 outlets are UL/ULC Listed,
LPC, Vds /FM approved for branch connections on wet and dry systems.
Dimensions - incheslmillimeters
The locating collar engages into the hole prepared in the pipe. When tightened, the assembly
compresses the gasket onto the OD of the pipe. The Style 922 Outlet -T is UL/FM rated up to 300 psi
(2068 kPa) and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems.
Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* It is supplied
+0.061 +1,5
with a clear, rust inhibitive coating. Contact Victaulic for other optional coatings.
u u VdS
Consult Section 10.01 for specific listings /approvals.
FM
V
See Victaulic
publication
for details.
Z
Ibslkg
1 X 1 /2
13 /16
1.30
1.83
DIMENSIONS
B � B IVI
Nominal Size
Hole
Inches/mm
Diameter
Dimensions - incheslmillimeters
Approx.
Run X Branch
+0.061 +1,5
Weight Each
FPTt
-0.00/ -0,0
T'
V
W
Y
Z
Ibslkg
1 X 1 /2
13 /16
1.30
1.83
1.10
3.87
2.56
1.0
32 X 15
30.2
33,0
46,5
27,9
98,3
65,0
0,45
1 X 3 /4
1
1.28
1.83
1.10
3.87
2.56
1.1
32 X 20
30.2
32,5
46,5
27,9
1 98,3
65,0
0,50
1 X 1
1
1.52
2.18
1.10
187
2.56
1.2
32 X 25
30,2
38,6
55.4
27,9
98,3
65,0
0.54
1 X '12
1
1.42
1.95
1.22
4.08
2.56
1.2
40 X 15
30,2
36,1
49,5
31,0
103,6
65,0
0,54
11 12 X 3 /4
1
1.40
1.95
1.22
4.08
2.56
1.2
40 X 20
30,2
1 35,6
49.5
31,0
103.6
65,0
0,54
1'/2 X 1
1
1.64
2.30
1.22
4.08
2.56
1.3
40 X 25
30,2
41,7
58,4
31,0
103,6
65,0
0,59
2 X 1 12
1
1.66
2.19
1.46
4.60
2.56
1.3
50 X 15
30,2
42,2
55,6
37,1
116,8
65,0
0,59
2 X 3 /4
1
1.64
2.19
1.46
4.60
2.56
1.4
50 X 20
30,2
41,7 1
55.6
37,1
116,8
65,0
0,64
2 X 1
1
1.88
2.54
1.46
4.60
2.56
1.5
50 X 25
30,2
47,8
1 64,5
37,1
116.8
65,0
0,68
t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male
threaded products with special features, such as probes, dry pendent sprinklers, etc., should be verified as suitable for use with this Vic-
taulic product. Failure to verify suitability in advance may result in assembly problems or leakage.
`Center of run to engaged pipe end for NPT threads (dimensions are approximate).
e REGISTERED TRADEMARK OF VICTAULIC - 0 COPYRIGHT 2003 VICTAULIC - PRINTED IN U.S.A.
3355 REV e
Victaulic Company of America • Phone: 1 - 800 - PICK -VIC (1 -800- 742 -5842) • Fax: 610 - 250 -8817 • e- mail:pickvic@viclaulic.com
Victaulic Company of Canada • Phone: 905 - 884 -7444 • Fax: 905 -884 -9774 • e -mail: viccanada@victaulic.com
Victaulic Europe • Phone:32 -9- 381 -1500 • Fax: 32 -9- 380 -4438 • e -mail: viceuro@victaulic.be
Victaulic America Latina • Phone: 610 - 559 -3300 • Fax: 610 - 559 -3608 • e -mail: vital @victaulic.com
Victaulic Asia Pacific • Phone: 65- 6235 -3035 • Fax: 65- 6235 -0535 • e -mail: vicap@victaulic.com
zicicta�ul�
c° °
10.52
PERFORMANCE
Nominal Size
Equivalent Length of 1' Pipe
Inches/mm
Feet/meters
1 1 / 4 X 1
8.5
32 x 25
2,6
1 1 /2 X 1
8.5
40 x 25
2,6
2 X 1
8.5
50 x 25
2,6
2 X 1
8.5
65 x 25
2,6
76,1 mm X 1
8.5
76,1 x 25
2,6
MATERIAL SPECIFICATIONS
Housing: Ductile iron conforming to ASTM A -395, grade 65- 45 -15, and ASTM A -536, grade 65 -45 -12
Gasket:
• Grade "E" EPDM -Type A
(Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and
Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated
working pressure using the Grade "E" Type A Gasket System.
Bolts /Nuts: Heat treated carbon steel zinc electroplated track head bolt with a minimum tensile strength
of 110,000 psi (758340 kPa). Flanged hex nut, zinc electroplated.
This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation /assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
Style 922 FireLock® Outlet -T
0 ■ .01
No. 50 and No. 51
Concentric /Eccentric Reducers
Steel (except as noted)
3 X
80 X
3 /4 +
No. 50
No. 51
Nominal
E to E
Approx.
E to E
Approx.
Size
Inches
Wgt. Ea.
Inches
WgL Ea.
Inches/mm
mm
LbsAg
mm
LbsAg
1114 X 3 /4
+
1.9
-
-
32 X 20
+
0.9
-
-
X 1
+
1.9
-
-
X 25
+
0.9
-
-
1'/z X 3 /4
+
1.4
-
-
40 x 20
6.0
0.6
-
-
X 1
2.50' d
0.8
8.50
4.5
X 25
64
0.4
216
2.0
X 1
2.50" d
1.0
-
-
X 32
64
0,5
-
-
2 X 3 /4
2.50' d
0.9
9.00
2.0
50 X 20
64
0.3
229
0.9
X 1
2.50" d
0.7
9.00
2.3
X 25
64
0.3
229
1.0
X 1 1 /4
2.50' d
1.2
9.00
4.6
X 32
64
0.5
229
2.1
X 1 '/ 2
2.50' d
1.0
9.00
4.6
X 40
64
0.5
229
2.1
3 X
80 X
3 /4 +
+ 1
1.5 +
+ 4
4.5
20 +
+ 0
0.7 +
+ 2
2.0
1 2
2.50' d 1
1.3 9
9.50 4
4.8
25 6
64 0
0.6 2
241 2
2.2
1 +
+ 3
3.0 +
+ 4
4.8
32 +
+ 1
1.4 +
+ 2
2.2
1 2
2.50' d 5
5.1 9
9.50 5
5.1
40 6
64 2
2.3 2
241 2
2.3
2 2
2.50' d 1
1.6 3
3.50 d 6
6.0
50 6
64 0
0.7 8
89 2
27
2 2
2.50' d 1
1.8 3
3.50 d 7
7.0
65 6
64 0
0.8 8
89 3
31
76,1 mm 2
2.50 d 2
2.1 -
- -
-
64 1
1.0 -
- -
-
-EtoE�
Grooved End Fittings