Loading...
HomeMy WebLinkAboutF10-0088 permitTOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Job Address: 1000 LIONS RIDGE LP VAIL Location.....: HOT TUB/POOL AREA, VAIL RUN Parcel No...: 210312105006 Project No ` cxlU — p 1 Zq OWNER VAIL RUN RESORT COMMUNITY AS 10/26/2010 1000 LIONS RIDGE LOOP VAIL CO 81657 APPLICANT WESTERN STATES FIRE PROTECTI 10/26/2010 7026 S TUCSON WAY ENGLEWOOD CO 80112 License: 338 -S CONTRACTOR WESTERN STATES FIRE PROTECTI 10/26/2010 7026 S TUCSON WAY ENGLEWOOD CO 80112 License: 338 -S Permit #: F10 -0088 Status ...: ISSUED Applied..: 10/26/2010 Issued . .. 10/27/2010 Expires. .: Phone: 303 - 792 -0022 Phone: 303 - 792 -0022 Desciption: REPAIR EXISTING SPRINKLER SYSTEM DUE TO NEW ROOF STRUCTURE. Valuation: $3,600.00 *********#****}***} fss##s###s###+*#** + * * # * * # * # * + +# * * * * * * * * * * * * * * * * ** FEE SUMMARY +}}s}+ f} f*+s*+#**}##+#**#**** f + *# * # *# * + * * * * * * * * * * * * * * * * * * * }} Mechanical - -> $0.00 Restuarant Plan Review —> $0.00 Total Calculated Fees - -> $585.00 Plan Check --- > $432.00 DRB Fee ---- — --- — -------- —> $0.00 Additional Fees--- - - - - -> $0.00 Investigation -> $0.00 TOTAL FEES--------- - - - - -> $585.00 Total Permit Fee ---------- > $585.00 Will Call - ---> $0.00 Payments ------------------- > $585.00 BALANCE DUE --------- > $0.00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 10/26/2010 mcgee Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. it SIGNATUREIF WNER OR VONPACTOR FOR HIMSELF AND OWNER ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001703 Amount: $585.00 10/27/201010:09 AM Payment Method: Check Init: LC Notation: #120581 / WESTERN STATES FIRE PROTECTION ----------------------------------------------------------------------------- Permit No: F10 -0088 Type: SPRINKLER PERMIT Parcel No: 2103 -121- 0500 -6 Site Address: 1000 LIONS RIDGE LP VAIL Location: HOT TUB /POOL AREA, VAIL RUN Total Fees: $585.00 This Payment: $585.00 Total ALL Pmts: $585.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code -------------- Description Current Pmts - - - BP 00100003111100 - -- ------------------------ - - - - -- ------ SPRINKLER PERMIT FEES - - - - -- 153.00 PF 00100003112300 ----------------------------------------------------------------------- PLAN CHECK FEES 432.00 - - - - -- c Department of Community Development 75 South Frontage Road ;�•. Vail, Colorado 81657 Tel: 970 -479 -2128 Fax: 970 - 479 -2452 Web: www.vailgov.com ^- e�elopmen Re ie C r 'n t ,. > :° Ow FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: 1000 LIONS RIDGE LOOP (Number) (Street) Building /Complex Name: VAIL RUN SPA/POOL Contractor Information: Companv: Western States Fire Protection (Suite #) Company Address: 7026 S. Tuscan Way City: Centennial State: CO Contact Name: Joe Hayden Contact Phone: 303 - 549 -8979 E -Mail joe.hayden @wsfp.us 80112 Town of Vail Contractor Registration No.: 338 -S X - Contractor Signature (required) Property Information Parcel #: 210312105006 (For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: VAIL RUN RESORT Owner Name: VAIL RUN RESORT COMMUNITY Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler $: $3,600 Office Use: Project #: Building Permit #: L � `D ~ 0055 Sprinkler Permit #: / � ll 00 9 03 Lot #: Block # Subdivision: Detailed Description of Work: REPAIR EXISTING SPRINKLER SYSTEM DUE TO NEW ROOF STRUCTURE (use additional sheet if necessary) Detailed Location of Work: Work will be preformed in area Does a Monitored Fire Alarm Exist? Yes ( ,,) No ( ) Does a Sprinkler System Exist? Yes(. No( ) Work Class: New ( ) Addition ( ) Remodel ( ) Repair (v ) Retro -Fit ( ) Other( ) Type of Building: Single- Family ( ) Duplex ( ) Multi - Family ( ) Commercial Restaurant ( ) Other ( ) Date Received: TOWN OF VAIL I�( OCT 25 2010 Ul 01- Feb -10 I///\ Western States v Fire Protection Co. RLOt;ctu� Ziuee "d �aa Material Submittal FOR VAIL RUN SPA /POOL 1000 LIONS RIDGE LOOP VAIL, CO 81657 Tenant Remodel Prepared by: Jeff Hagan Project Manager Western States Fire Protection Co. 7026 S. Tucson Way Centennial, CO 80112 Phone (303) 792 -0022 Fax (303) 792 -9049 Cell (303 -549 -9553 Email jeff.hagan @wsfp.us WSFP #CS0997 October 24, 2010 MATERIAL INDEX VII. Grooved Fittings A. Description Model Manufacturer I. Sprinkler Heads Style 005 Victaulic C. A. Standard Spray Quick Response Upright Sprinkler F1FR -R3625 Reliable D. B. Standard Spray Quick Response Semi - Recessed Pendant F 1 FR -R3615 Reliable III. Pipe — 1 -1/2" and smaller threaded A. Black Schedule 40 Pipe ASTM A 795 Varies" IV. Pipe — 2" and larger grooved A. Black Schedule 10 Pipe ASTM A135 Varies" V. Cast Iron Fittings Varies Varies" VI. Pipe Hangers (Per NFPA 13) A. All Thread Rod Fig. 100 Tolco B. Adjustable Ring Hanger Fig. 200 Tolco C. C -Clamp Top Beam w /Locknut Fig. 68 Tolco VII. Grooved Fittings A. Grooved Firelock Fittings Varies Victaulic B. Grooved Firelock Rigid Couplings Style 005 Victaulic C. Mechanical T, Bolted Branch Outlet Style 920/922 Victaulic D. Grooved Concentric Reducer Style 50/51 Victaulic "Because of the current escalation occurring with steel, WSFP reserves the right to substitute pipe as required to meet project schedules. Reli Bulletin 136 Rev.M Model F1 FR Model F1 FR Recessed Quick Response Sprinklers Model F1 FR Sprinkler Types S tandard pright — 5' an ar en enT Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector odel F1 FR Recessed Sprinkler Ty pes Recessed Pendent Hecessed Horizontal I ewa - HSW 1 Deflector Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) 5. NYC BS&A No. 587 -75 -SA 6. Meets MIL- S -901C and MIL -STD 167 -1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93 -E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model F1 FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Z3 C0 x- W 30 CR r Recessed Pendent (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Installation Data: Sprinkler Type Standard - Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position K Factor Sprinkler p Height Approval APP Organization Sprinkler Identification Number SIN Us Metric __, SSU SSP 15mm Standard Orifice with " NPT R,ti" Thread 5.6 80 2.2" 56mm 1,2,3,4,5,6,7 R3625 R3615 2 0mm) Large Orifice with 4 NPT ( R 3 /, )Thread 8.0 115 2.3" 58mm 1,2,3,4,7,8 R3622 R3612 " 17mm Small Orifice with y" NPT Ri) Thread 4.2 60 2.2" 56mm 1,2,8 R3623 R3613 10mm Small Orifice with , "NPT R,; Thread 2.8 40 2.2" 56mm 1,2,8 R3621 R3611 10mm Orifice XLH with R'/8 " Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional-Install in Upright or Pendent Position 4.2 5.6 8.0 60 80 115 56mm 56mm 58mm 4,6,7 4,7 R3674 R3675 R3672 10mm Orifice XLH with R Thread 15mm Standard Orifice with }z' NPT (Ry) Thread 20mm Large Orifice with 3 /;' NPT (R )Thread Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) US Metric 1 2 ' (15mm) 12 " NPT (R 5.6 80 2.2'(56mm) 1,2,3,4,5,7,8 R3615 32 (20mm);' NPT (R /,) 8.0 115 2.3" (58mm) 1,2,3,8 R3612 ;s' (11 mm) 1z" NPT (R'/2) 4.2 60 2.2" (56mm) 1,2,8 R3613 ?B' (10mm) Jz " NPT (R' /2) 2.8 40 2.2'(56mm) 1,2,8 R3611 10mm we 4.2 60 56mm 4,7 R3614 (') Refer to escutcheon data table for approvals and dimensions. 1 /8 (l7 I z 172 2IF a s ` t In.r—/ '1 rxrOUr E 1 WER IIJ F/ t E2 ESCO-Wr[w 00A TA" MR 4RFROV44S AND Dwrl 50iS. 1 5 /6" Do. (66.7mj - -- I40" MI MAC ? S, /r6' DM, [58.7mm] Can F12' R£DUCCR �-- _ _ - _ _ _ 1 I " .r 1 Q V - FACt Ur F,7TING TO FAC£ OF CFILINC DWFN501 M ADJUSTMENT (!) RLFLR TO rF LSCaTCI IWA MULL rOR A,PRCNAL5 AN✓ DMLN59 5 2. C S 1,/4' "Ott D!A _— jSLrm+iJ (ag r�l I � X ! /r' RFDCk;FF UvT4 "!(IfT „ Grri SRau.nrn ?'AA-N BO55 i I 1 1 /8 (l7 I z 172 2IF a s ` t In.r—/ '1 rxrOUr E 1 WER IIJ F/ t E2 ESCO-Wr[w 00A TA" MR 4RFROV44S AND Dwrl 50iS. 1 5 /6" Do. (66.7mj - -- I40" MI MAC ? S, /r6' DM, [58.7mm] Can F12' R£DUCCR �-- _ _ - _ _ _ 1 I " .r 1 Q V - FACt Ur F,7TING TO FAC£ OF CFILINC DWFN501 M ADJUSTMENT (!) RLFLR TO rF LSCaTCI IWA MULL rOR A,PRCNAL5 AN✓ DMLN59 5 2. C Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1 FR Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model F1 FR Sprinklers. The use of any other recessed escutch- eon Will void all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1 FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classification Sprinkler Tem erature Max. Ambient Bulb peon Approvals Temp. Color °C j °F Ordinar Sprinkler Wall Dimension Bright Brass Bright Brass 1 1 Black Plated Black Paint F1 1,2,4,8 Iritermeolale (38.1mm) 11b 1507 M6 -- 7ellow Intermediate (5mm -24mm) 19.1mm reen High (t) 141 286 225 °F (107 °C) Blue Not available for recessed sprinklers. Escutcheon Data ES Sprinkler Escutch Face of Fitting peon Approvals Adjustment Chrome Plated (3) to Ceiling or White Painted (3) Special Application Finishes Sprinkler Wall Dimension Bright Brass Bright Brass Black Plated Black Plated Black Paint F1 1,2,4,8 Max Recess (38.1mm) 'a° '3;8' Min Recess %" (5mm -24mm) 19.1mm 1y" F2 1,2,3,4,5,7,8 Max Recess (38.1mm) 38" 'Ye" Min Recess '% fi (5mm -17mm) 24mm FP 1,2 _ Max Recessed is 1y" (38.1mm) 11 PushoN Thread -off 1,2 Min Recessed 1 "(25.4mm) 24mem No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishe t " Sta Finishes Sprinkler Escutch Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated White Painted (3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome ( Other finishes and colors are available on special order. Consult the factory for details. ( FM Approvals is limited to bronze and brass, chrome or black plated finishes only. (3) FP Push- on/rh read -off escutcheon Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1 FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property forover 80years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800)431 -1588 Sales Offices (800)848-6051 Sales Fax (914)668-3470 Corporate Offices www.reliablesprinkler.com Internet Address 0 Recycled Paper Revision lines indicate updated or new data EG. Printed in U.S.A. 7/05 P/N9999970027 Component of State of California OSHPD Approved C & USTED Seismic Restraints System Fig. 100 -All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10' lengths Material — Carbon Steel Maximum Temperature — 750 °F Finish — Plain Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions - Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650 °F 750 °F Wt. /100 1/4 240 215 12 610 540 1 1130 101 5 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1 1 /4 8000 7140 360 1 11630 10370 510 ® OFFICE/MANUFACTURING FACILITY - 1375 SAMPSON AVE, - CORONA, CA 92879 - PH: 951.737.5599 - FAX: 951.737.0330 CUSTOMER SERVICE - 800.786.5266 wwwlo/co'com Fig. 200 - "Trimline" Adjustable Band Hanger C & OS LISTED Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2 ") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2 thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8 ") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8 "). Conforms to Federal Specifications WW -H -171 E, Type 10 and Manufacturers Standardization Society SP -69, Type 10. Maximum Temperature — 650 °F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOW Fig. 200WON. Order By — Figure number and pipe size 2 1/2 THRU 8 INCH PIPE Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 3� 2 400 11 3/4 3/8 8mm or 10mm 318 2 400 11 1 3/8 8mm or 1 Omm 3H 2% 400 12 1 1 /4 1 �h 2 3/8 3/8 3/8 8mm or 10mm 8mm or 10mm 8mm or 10mm 3Y4 3 4 2 2 3 400 400 400 13 14 15 2h 3 3/8 3/8 10mm 10mm 5Y8 5 4t'A 4 600 600 27 29 mm a 600 34 4 3/8 10mm 71/8 5 1000 35 5 1/2 12mm 9/a 6Ya 1250 66 6 1/2 12mm 101/8 6 1250 73 8 1/2 12mm 13 8 1250 136 OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Jj Fig. 68 - Wide Throat Top Beam "C" Clamp w /Locknut Size Range — 3/8" thru 3/4" rod Function — For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals — Conforms to Federal Specification WW -H -171 E, Type 23 and Manufacturers Standardization Society SP -69, Type 19. Finish — Plain Note — Available in Electro- Galvanized finish. Order By — Figure number, rod size and finish Note — Do not over tighten set screw. Dimensions • Weights Rod Max. Rec. Approx. Size Load Lbs. WtJ100 3/8 400 34 1/2 500 50 5/8 600 53 3/4 800 86 LV y i ® OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951 737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 10.03 FireLock® Fittings PRODUCT DESCRIPTION VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full -flow elbows and tees are a CAD - developed, hydrodynamic design that has a shorter center -to -end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. Patented FM See Victaulic publication 10.01 for details. DIMENSIONS I. to E� ctoE� a � ° c ✓ ° to E L o0 No. 001 No. 003 c �toE� No. 001 No. 003 No. 002 No. 006 C olo E to E T - t No. 002 No. 006 e REGISTERED TRADEMARK OF VICTAUUC - O COPYRIGHT 2006 VICTAUUC - PRINTED IN U.S.A. - SKU NWCAS- 67PJUx United States • Phone: 1 - 800 - PICK -VIC (1- 800 - 742 -5842) • Fax: 610 - 250 -8817 • e -mail: pickvic @victaulic.com Canada • Phone: 905 -884 -7444 • Fax: 905- 884 -9774 • e -mail: viecanada@victaulic.com Europe • Phone: 32 -9- 381 -1500 • Fax: 32-9-380-4438 • e -mail: viceuro@victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e -mail: viceuro@Victaulic.be Central and South America • Phone: 610- 559 -3300 • Fax: 610 -559 -3608 • e -mail: vical@victaulic.com Australasia • Phone: 86- 21- 54253300 • Fax: 86-21-54253671 • e -mail: vicap@viclaulic.com 1539 REV F 1�'tic�U'I�i® No. 001 No. 003 No. 002 No. 006 Fitting Size 90° Elbow 45° Elbow Straight Tee Cap Actual Aprx. Aprx. Aprx. Thickness Aprx. Nominal Outside C to E Weight C to E Weight C to E Weight ­r Weight Diameter Diameter Inches Each Inches Each Inches Each Inches Each Inches/mm Inches/mm mm LbsJkg mm LbsJkg mm LbsJkg mm LbsJkg 11 14 1.660 - - - - - - 0.82 0.3 32 42.4 - - - - - - 21 0.1 1 1.900 2.75 1.2 1.75 0.9 2.75 2.0 0.82 0.4 40 48.3 70 0.5 45 4.1 1 70 0.9 21 02 2 2.375 2.75 1.7 2.00 1.8 1 2.75 2.4 0.88 0.6 50 60,3 70 0.8 51 0.8 70 1.1 22 0.3 2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - - - 76.1 76 1.5 57 1.1 - - I - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 e REGISTERED TRADEMARK OF VICTAUUC - O COPYRIGHT 2006 VICTAUUC - PRINTED IN U.S.A. - SKU NWCAS- 67PJUx United States • Phone: 1 - 800 - PICK -VIC (1- 800 - 742 -5842) • Fax: 610 - 250 -8817 • e -mail: pickvic @victaulic.com Canada • Phone: 905 -884 -7444 • Fax: 905- 884 -9774 • e -mail: viecanada@victaulic.com Europe • Phone: 32 -9- 381 -1500 • Fax: 32-9-380-4438 • e -mail: viceuro@victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e -mail: viceuro@Victaulic.be Central and South America • Phone: 610- 559 -3300 • Fax: 610 -559 -3608 • e -mail: vical@victaulic.com Australasia • Phone: 86- 21- 54253300 • Fax: 86-21-54253671 • e -mail: vicap@viclaulic.com 1539 REV F 1�'tic�U'I�i® 10.03 FLOW DATA MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A -536, grade 65 -45 -12 Fitting Coating: Orange enamel • Optional: Hot dipped galvanized This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. FireLock® Fittings Frictional Resistance Fitting Size Equivalent FeeUmeters of Straight Pipe Actual Straight Tee Nominal Outside No. 002 Diameter Diameter 90° Elbow 45° Elbow Inches/mm Inches/mm No. 001 No. 003 Branch Run 1 1 /4 1.660 1.5 0.8 33 1.5 32 42.4 0.5 0.2 1.1 0.5 1 1 /2 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2 1 / 2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 13 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 1 88.9 1 1.5 0.8 4.0 1 5 MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A -536, grade 65 -45 -12 Fitting Coating: Orange enamel • Optional: Hot dipped galvanized This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. FireLock® Fittings �ctaulic° An ® 9001 certified company Vic INUq Gasket System PRODUCT DESCRIPTION FireLockTM Style 005 rigid coupling has a unique, pat- ented angle -pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Patented DIMENSIONS Rated for wet and dry sprinkler systems at 350 PSI (2413 kPa) for 1 - 4 (42,4 - 114,3 mm) sizes and 300 PSI (2068 kPa) for 4 - 8' (108,0 - 219,1 mm) sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expan- sion, contraction or angular deflection. The FireLock couplings provide rigidity for valve connections, fire mains and long straight runs. Support and hanging requirements correspond to NFPA 13 Style 005 FireLock " Rigid Coupling with Vic -Plus- Gasket System Sprinkler Systems. Angle - pad design permits assem- bly by removing one nut/ bolt and swinging the housing over the gasket. This reduces components to handle during assembly; speeds and eases installa- tion on pipe grooved to Victaulic specifications. Style 005 FireLock cou- plings with the Vic - Plus' Gasket System are designed and rec- ommended for use § LPC and VdS Approved, see notes on page 2. ONLY on fire protection systems. Vic -Plus Gasket System: Victaulic now offers a gas- ket system which requires no field lubrication. The Vic- Plus System (patent pending) is dry, clean, and non -toxic. It reduces assembly time substantially and eliminates the mess and chance of over - lubrication. 10.02 -10 SIZE Max. Max. Allow. Dimensions Nominal Work. End Pipe End @ Bolt/Nut Inches Aprx. Inches Press. § Load Sep. t No. - Size Wgt. Ea. Acnea3 mr, PSI' /kP n Lbs.' /rt In. /mm Inches /mm X Y Z Lbs. /Kg 1 1 /4 350 755 0.05 2.75 4.50 1.88 1.2 2 - X 2 1'h 350 990 0.05 2 - 3 /e X 2 3.00 4.75 1.88 1.2 2 350 1550 0.07 3.50 5.25 1.88 1.6 2-% X 21h 2 350 2270 0.07 2 - 3 /4 X 2 4.00 5.75 1.88 1.9 76,1 mm 350 2475 0.07 2- 3 AX2'h 4.13 5.75 1.88 1.9 3 350 3365 0 07 2 3 /e X 2'h 41.63 6 13 1.88 2.1 - ® § t Refer to notes on page 2. Victaulic World Headquarters • P.O. Box 31, Easton, PA 18044 -0031 •4901 Kesslersville Rd., Easton, PA 18040.1 -800 -PICK VIC • FAX: 610/250 -8817 • www.victatilic.com 1538 Rev.E 10100 ® Registered Trademark of Victaulic ® Copyright 1999 Victaulic Printed in U.S.A. MATERIAL SPECIFICATIONS Housing: Ductile iron conform- ing to ASTM A -395, grade 65- 45-15, and ASTM A -536, grade 65- 45 -12. Housing Coating: Orange enamel ❑ Optional: Hot dipped galva- nized Gasket: ❑ Grade "E" EPDM - Type A Vic -Plus Gasket System t (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler ser- vices up to the rated working pressure using the Grade "E" Type A Vic -Plus Gasket System, requiring no field lubrication. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal Vic -Plus Gasket System. Contact Victaulic for details. Bolts/Nuts: Heat treated car- bon steel, zinc electroplated to ASTM B -633; Track head bolt conforming to ASTM A -183 minimum tensile 110,000 PSI (758340 kPa); Flanged hex nut conforming to ASTM A -563, Grade A. t Standard gasket and FlushSeal gasket approved for dry pipe systems to -40 °F (- 40 °C). Supplemental lubricant is rec- ommended for services installed at or continuously operating below 0 °F (- 18 °C). Victaulic continues to recom- mend the use of FlushSeal gaskets for dry services. The information provided below is based on the latest listing and approval data at the time of publication. Listings /Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 10.02 -zA Rated Working Pressure Rated Working Pressure Pipe Schedule Size Inches UL ULC FM Pipe Schedule Size Inches UL ULC FM 5 1 175 175 175 EZ 4 300 300 300 10,40 1 350 350 350 6 175 175 175 5-8 300 300 300 SF 1 300 300 300 BLT 1 300 300 300 Super 40 1 300 300 300 DF 1 300 300 300 TL 1 300 300 300 6 175 175 175 WLS 1 300 300 300 DT 1 300 300 300 XL/XL -II 1 300 300 300 EL 1 300 300 300 NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe. 10 refers to Listed /Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. BLT refers to Listed/Approved steel sprinkler pipe manufactured by American Tube Company. DF refers to Listed/Approved Dyna -Flow steel sprinkler pipe manufactured by American Tube Company. DT refers to Listed/Approved Dyna Thread steel sprinkler pipe manufactured by American Tube Company. EL refers to Listed/Approved Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed/Approved EZ -Flow steel sprinkler pipe manufactured by Northwest Pipe & Casing Co. SF refers to Listed/Approved Super -Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. SL refers to Listed/Approved steel sprinkler pipe manufactured by Western Tube and Conduit Corporation. Super 40/XL refers to Listed/ Approved Super 40 or Super XL steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. WLS refers to Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. XL/XL -II refers to Listed/Approved XL or XL -II steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. NOTES Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accor- dance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1 /2 times the figures shown. t For field installation only. FireLock Style 005 couplings are essentially rigid and do not accommodate expansion /contraction. Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar (175 PSI). WARNING: Piping systems must always be depressurized and drained before attempting disassembly and removal of any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 10.90-2 Mechanicakr STYLES 920 AND 920N STYLES 920 AND 920N Victaulic Mechanical -T Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross -type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to achieve a cross connection. Style 920 and Style 920N Mechanical -T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500psi /345OkPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly - butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical -T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. STYLE 920 CROSS PATENTED MATERIAL SPECIFICATIONS Housing /Coating: Ductile iron conforming to ASTM A -536, grade 65- 45 -12, with orange enamel coating. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. • Optional: Hot dipped galvanized JOB OWNER System No. Gasket: (Specify choice *) • Grade "E" EPDM EPDM (Green color code). Temperature range -30 °F to +230 °F / -34 °C to +110 °C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL Classified in accordance with ANSI /NSF 61 for cold +86 °F / +30 °C and hot +180 °F / +82 °C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T" nitrile Nitrile (Orange color code). Temperature range -20 °F to +180 °F / -29 °C to +82 °C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150 °F / +66 °C or for hot dry air over +140 °F / +60 °C. 'Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. CONTRACTOR Submitted By Date Location ENGINEER Spec Sect Para Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV -1 ✓ ctsulid 11.02_1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical -r Bolted Branch Outlets STYLES 920 AND 920N 11.02 U FM ULC Vds �l SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N DIMENSIONS 4 STYLE 920 CROSS PATENTED Y Z tliYa• . _ MIM MM 2 x %2 (a) 920N 500 0 1.50 2.00 2.53 1.61 5.35 2.75 3.1 V 50 15 3450 38.1 51 64 41 136 70 1.5 (a) j 920N 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 _ i 20 3450 38.1 50 64 41 136 70 1.5 I (a) 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 _ / W 25 920N 3450 38.1 47 64 41 136 70 1.4 1 '/4 (a) t 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1 12 (a) t 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 v r - Z V / T IR FEMALE THREADED OUTLET IMPORTANT NOTES: TABLE CONTINUED ON PG. 3 Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. X . A 11.02._2 REV 76.1 x Vz (a) 920 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at ' A (a) 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 any location where a hole can be cut _20 920 2065 38.1 56 70 - 57 164 81 1.8 in the pipe 1 (a) 920 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1''A(a) 920 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1'h (a) 920 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical -T cross assemblies 3 x ,h (a) 920N 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 _ 80 15 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi /3450 kPa -% (a) 920N 500 1.50 2.49 3.05 - 2.28 6.15 2.75 34 _ on steel pipe; also available for use 20 3450 38.1 63 78 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1 /2 750 x 15 mm _ 1 Ya (a) t) 1 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4 7200 x 100mm 32 (b 1 3450 44.5 65 83 90 58 156 76 1.8 1.8 h (a) i 920N 40 (b) 500 3450 2.00 50.8 2.78 71 3.50 89 3.56 90 2.28 6.15 3.25 4.1 3.8 - --- -- 58 156 83 1.9 1.8 2 (a) 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 IMPORTANT NOTES: TABLE CONTINUED ON PG. 3 Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. X . A 11.02._2 REV IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical -r Bolted Branch Outlets STYLES 920 AND 920N 11.02 U FM > �( •� SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N DIMENSIONS ._ Ju Irl GROOVED OUTLET Ivl FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical -T cross assemblies • Pressure rated up to 500 psi /3450kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1 h "/50 x 15 mm through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. 4 STYLE 920 CROSS PATENTE " Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. # Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order (b) For 76.1 mm threaded outlet, specify 2 BSPT clearly on order. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. �1rit.'al.� REV _1 11.02 .5 TABLE CONTINUED FROM PAGE 4 1 165.1 x 920 500 1.50 3.88 4.56 _ 3.79 9.34 2.75 8.0 _ 25 3450 38.1 99 116 96 237 70 3.6 1 A 920 500 1.75 4.43 5.13 _ 3.79 9.34 3.25 8.4 _ 32 3450 44.5 113 130 96 237 83 3.8 1'h (a) t 920 500 2.00 4.41 5.13 _ 3.79 9.34 3.25 8.4 _ 40 3450 50.8 112 130 96 237 83 3.8 2 (a) t 920 500 2.50 4.38 5.13 _ 3.79 9.34 3.88 8.5 _ 50 3450 63.5 111 130 96 237 99 3.9 2'h t 920 500 2.75 4.01 5.13 _ 3.63 10.51 4.63 8.6 7.6 65 3450 69.9 110 130 92 267 118 3.9 3.4 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3 (a) t 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4 (a) t 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 _ 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2 (a) t x 920 S00 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 _ 50 _ 3450 69.9 138 157 159 122 316 114 5.3 5.3 2'h (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm 920 500 2.75 _ _ 6.25 4.81 12.42 4.56 _ 11.6 3450 69.9 159 122 316 116 5.3 3 (a) t 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4 (a) t 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 " Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. # Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order (b) For 76.1 mm threaded outlet, specify 2 BSPT clearly on order. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. �1rit.'al.� REV _1 11.02 .5 ' IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical -T® Bolted Branch Outlets FM Vds ft SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N FLOW DATA L1 Exaggerated for Clarity 54 STYLES 920 AND 920N STYLE 920 CROSS PATENTED Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 90ON and 929 Mechanical -TI fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C Values Values for flow of water at +60 °F / +16 °C are shown in the table below. 'fi 0.840 2.0 15 213 _ 0.6 % 1.050 4.0 2 26.7 _ 1.2 1 1.315 5.0 25 33.7 _ 1.5 1 % 1.660 5.5 6.0 32 1 42.4 1.7 1.8 1 'V 1 1.900 7.0 8.0 40 48.3 2.1 2A Formulas for C Values: AP = Q Where: C 22 Q = Flow (GPM) AP = Pressure Drop (psi) Q = C„ x JA C� = Flow Coefficient 2 2.375 9.0 10.5 50 60.3 2.7 3.2 2'fi 2.875 11.0 12.5 65 73.0 3.4 3.8 3 1500 13.5 15.5 80 88.9 4.1 4.7 4 4.500 20.0 22.0 100 114.3 61 6.7 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. iataulicr 11.02 6 REV I • IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical -T® Bolted Branch Outlets STYLES 920 AND 920N APPROVED PRESSURE RATINGS 1 1.02 UL FM ULC VdS " SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N STYLE 920 CROSS PATENTED The information provided below is based on the latest listing and approval data at the time of publi- cation. Listings /Approvals are subject to change and /or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2-6 2.875 - 6.625 All 10, 40 400 400 400 6 5-15 0 73.0- 168.3 2755 2755 2755 21/2-4 2.875 - 4.500 All DF 300 300 300 65 - 100 73.0-114.3 2065 2065 2065 21/2-4 2.875 - 4.500 All SF 300 300 300 65 -1 73.0 -114.3 2065 2065 2065 6 6.625 3,4 0 300 300 250 150 168.3 2065 2065 1724 6 6.625 3,4 30, 40 300 300 300 150 168.3 2065 2065 2065 2 2 /2 10, 40 2 00 _ — 200 625 8 8.625 3,4 10 300 _ 250 2 219.1 2065 1724 8 8.625 3,4 30, 40 300 _ 300 200 219.1 2065 2065 NOTES: 10 refers to Listed /Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed /Approved Schedule 40 steel sprinkler pipe. OF refers to Listed /Approved Dyna -Flow steel sprinkler pipe manufactured by American Tube Company SF refers to Listed /Approved Super -Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. dtiit.'t REV 1 11.02 7 10.52 Style 922 FireLock° Outlet -T VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION DIMENSIONS B � B IVI Nominal Size The Style 922 Outlet -T provides a convenient method of incorporating 1 12, 3 /4, and 1' (15, 20 and 25 mm) outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. + Available for 1 through 76,1 mm (32 to 76,1 mm) piping systems, Style 922 outlets are UL/ULC Listed, LPC, Vds /FM approved for branch connections on wet and dry systems. Dimensions - incheslmillimeters The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet -T is UL/FM rated up to 300 psi (2068 kPa) and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* It is supplied +0.061 +1,5 with a clear, rust inhibitive coating. Contact Victaulic for other optional coatings. u u VdS Consult Section 10.01 for specific listings /approvals. FM V See Victaulic publication for details. Z Ibslkg 1 X 1 /2 13 /16 1.30 1.83 DIMENSIONS B � B IVI Nominal Size Hole Inches/mm Diameter Dimensions - incheslmillimeters Approx. Run X Branch +0.061 +1,5 Weight Each FPTt -0.00/ -0,0 T' V W Y Z Ibslkg 1 X 1 /2 13 /16 1.30 1.83 1.10 3.87 2.56 1.0 32 X 15 30.2 33,0 46,5 27,9 98,3 65,0 0,45 1 X 3 /4 1 1.28 1.83 1.10 3.87 2.56 1.1 32 X 20 30.2 32,5 46,5 27,9 1 98,3 65,0 0,50 1 X 1 1 1.52 2.18 1.10 187 2.56 1.2 32 X 25 30,2 38,6 55.4 27,9 98,3 65,0 0.54 1 X '12 1 1.42 1.95 1.22 4.08 2.56 1.2 40 X 15 30,2 36,1 49,5 31,0 103,6 65,0 0,54 11 12 X 3 /4 1 1.40 1.95 1.22 4.08 2.56 1.2 40 X 20 30,2 1 35,6 49.5 31,0 103.6 65,0 0,54 1'/2 X 1 1 1.64 2.30 1.22 4.08 2.56 1.3 40 X 25 30,2 41,7 58,4 31,0 103,6 65,0 0,59 2 X 1 12 1 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 30,2 42,2 55,6 37,1 116,8 65,0 0,59 2 X 3 /4 1 1.64 2.19 1.46 4.60 2.56 1.4 50 X 20 30,2 41,7 1 55.6 37,1 116,8 65,0 0,64 2 X 1 1 1.88 2.54 1.46 4.60 2.56 1.5 50 X 25 30,2 47,8 1 64,5 37,1 116.8 65,0 0,68 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinklers, etc., should be verified as suitable for use with this Vic- taulic product. Failure to verify suitability in advance may result in assembly problems or leakage. `Center of run to engaged pipe end for NPT threads (dimensions are approximate). e REGISTERED TRADEMARK OF VICTAULIC - 0 COPYRIGHT 2003 VICTAULIC - PRINTED IN U.S.A. 3355 REV e Victaulic Company of America • Phone: 1 - 800 - PICK -VIC (1 -800- 742 -5842) • Fax: 610 - 250 -8817 • e- mail:pickvic@viclaulic.com Victaulic Company of Canada • Phone: 905 - 884 -7444 • Fax: 905 -884 -9774 • e -mail: viccanada@victaulic.com Victaulic Europe • Phone:32 -9- 381 -1500 • Fax: 32 -9- 380 -4438 • e -mail: viceuro@victaulic.be Victaulic America Latina • Phone: 610 - 559 -3300 • Fax: 610 - 559 -3608 • e -mail: vital @victaulic.com Victaulic Asia Pacific • Phone: 65- 6235 -3035 • Fax: 65- 6235 -0535 • e -mail: vicap@victaulic.com zicicta�ul� c° ° 10.52 PERFORMANCE Nominal Size Equivalent Length of 1' Pipe Inches/mm Feet/meters 1 1 / 4 X 1 8.5 32 x 25 2,6 1 1 /2 X 1 8.5 40 x 25 2,6 2 X 1 8.5 50 x 25 2,6 2 X 1 8.5 65 x 25 2,6 76,1 mm X 1 8.5 76,1 x 25 2,6 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -395, grade 65- 45 -15, and ASTM A -536, grade 65 -45 -12 Gasket: • Grade "E" EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts /Nuts: Heat treated carbon steel zinc electroplated track head bolt with a minimum tensile strength of 110,000 psi (758340 kPa). Flanged hex nut, zinc electroplated. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Style 922 FireLock® Outlet -T 0 ■ .01 No. 50 and No. 51 Concentric /Eccentric Reducers Steel (except as noted) 3 X 80 X 3 /4 + No. 50 No. 51 Nominal E to E Approx. E to E Approx. Size Inches Wgt. Ea. Inches WgL Ea. Inches/mm mm LbsAg mm LbsAg 1114 X 3 /4 + 1.9 - - 32 X 20 + 0.9 - - X 1 + 1.9 - - X 25 + 0.9 - - 1'/z X 3 /4 + 1.4 - - 40 x 20 6.0 0.6 - - X 1 2.50' d 0.8 8.50 4.5 X 25 64 0.4 216 2.0 X 1 2.50" d 1.0 - - X 32 64 0,5 - - 2 X 3 /4 2.50' d 0.9 9.00 2.0 50 X 20 64 0.3 229 0.9 X 1 2.50" d 0.7 9.00 2.3 X 25 64 0.3 229 1.0 X 1 1 /4 2.50' d 1.2 9.00 4.6 X 32 64 0.5 229 2.1 X 1 '/ 2 2.50' d 1.0 9.00 4.6 X 40 64 0.5 229 2.1 3 X 80 X 3 /4 + + 1 1.5 + + 4 4.5 20 + + 0 0.7 + + 2 2.0 1 2 2.50' d 1 1.3 9 9.50 4 4.8 25 6 64 0 0.6 2 241 2 2.2 1 + + 3 3.0 + + 4 4.8 32 + + 1 1.4 + + 2 2.2 1 2 2.50' d 5 5.1 9 9.50 5 5.1 40 6 64 2 2.3 2 241 2 2.3 2 2 2.50' d 1 1.6 3 3.50 d 6 6.0 50 6 64 0 0.7 8 89 2 27 2 2 2.50' d 1 1.8 3 3.50 d 7 7.0 65 6 64 0 0.8 8 89 3 31 76,1 mm 2 2.50 d 2 2.1 - - - - 64 1 1.0 - - - - -EtoE� Grooved End Fittings