Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M10-0221
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT 0 MWWOFVR Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 4650 MEADOW DR VAIL Location.....: UNIT 1107 Parcel No...: 210112404007 OWNER WALTERS, SCOTT R- HORAK, KE 10/08/2010 15201 INDIAN BOUNDARY RD PLAINFIELD IL 60544 APPLICANT MOUNTAIN MAN FIREPLACE AND C 10/08/2010 Phone: 303 - 679 -1601 7001 HIGHWAY 73 EVERGREEN CO 80439 License: 438 -M CONTRACTOR MOUNTAIN MAN FIREPLACE AND C 10/08/2010 Phone: 303 - 679 -1601 7001 HIGHWAY 73 EVERGREEN CO 80439 License: 438 -M Desciption: INSTALLATION OF A NEW WOODSTOVE Valuation: $1,455.15 ALL TIMES Permit #: M10-0221 Project #: PRJ10 -0652 Status ...: ISSUED Applied..: 10/08/2010 Issued . .: 10/26/2010 Expires. .: 04/24/2011 **#####***###*#*#**#*#***#*****««*«******««««««* * * « «««*« « ««« « # * ««# « # # *«* * « « «##* # FEE SUMMARY #***#*****#**#**#***********#**********«************** * *#** * * * *** * * * **##*# *** ******** Mechanical Permit Fee --- > $40.00 Will Call ------------ > $4.00 Total Calculated Fees - -> $54.00 Plan Check--------- - - - - -> $10.00 Use Tax Fee ------ > $0.00 Additional Fees -- ------ –> $0.00 Investigation ------------ – --- > $0.00 TOTAL PERMIT FEE --- > $54.00 Total Calculated Fees - -> $54.00 Payments -------- — ------ > $54.00 BALANCE DUE--- - - - - -> $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 10/21/2010 JRM Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - d PM /-\ --- � Signature of jOwner or Contractor AJ ( �,)0-4 �.�- Print Name /0 l r� Date mech ca n ica I – pe rm it- 041908 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001691 Amount: $54.00 10/26/201010:44 AM Payment Method: Check Init: LC Notation: #13212 / MOUNTAIN MAN FIREPLACE & CHIMNEY ----------------------------------------------------------------------------- Permit No: M10 -0221 Type: MECHANICAL PERMIT Parcel No: 2101 -124- 0400 -7 Site Address: 4650 MEADOW DR VAIL Location: UNIT 1107 Total Fees: $54.00 This Payment: $54.00 Total ALL Pmts: $54.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - MP 00100003111100 - -- ------------------------ - - - - -- ------ MECHANICAL PERMIT FEES - - - - -- 40.00 PF 00100003112300 PLAN CHECK FEES 10.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 k. • Complete Mechanical Room Floor Plan with Dimensions • Combustion Air Duct Size and Location • Flue detail or Vent size, location & termination • Gas Piping layout including development length calculations • Heat Loss Calculations ❑ Boiler size & efficiency X Equipment Cut Sheets for Fireplaces /Log Sets manufacturer's Into showing make, model & approval listin Office Use: DE V 1 it 00 13 Project #: _ Pas " 1 0 - rrps,a Building Permit #: - Mechanical Permit #: I D oZ __ _ _. .._.._ _ . __..___...: Define Scope and Location of Work: Contractor Inforltion: Company: Mourhifi MIJ11 ' A'rp F / Company Address: 7Od / l a� 1a) /J , r l 3 City: , State: vv Zip: gL9 g 39 (use additional sheet if necessary) Contact Name: Ia :U4N SO Al 2 2 �" ❑ Gas Piping Included Contact Phone: 30 3 tY / 9 - CO ❑ Gas Piping by Others E -Mail p, ❑ Wood to Gas Fireplace Conversion Town of Vail Contra or egistration No.: L J tj - �� Boiler Location: Interior ( ) Exterior ( ) Other ( ) X Numhpr of 1=xis +inn Firanlarcc- Project Street Addres : Li& 0 VaO 4tyaet Olrb ri 1107 (Number) (Street) \ ((Suite #) Building /Complex Name: V / A� �- �'t+ — awe+ u-l� Co ractor ignature (required) roperty, information a \ Parcel : 'a» \ - 1 AA-# ©LA — an (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us / patie) ] Tenant Name: V t�(,i � Q q FAQ -� a / k-)�2 (Commercial roperties) Owner Name: bd'q /4 .0r Complete Valuation for Mechanical Permit: (including fireplps) Mechanical $: C: \cdev \forms\ permits \bu i id ing \mechanical _permit_010110 Gas Appliances y Gas Logs Wood /Pellet Number of Proposed Fireplaces: Gas Appliances Gas Logs Wood /Pellet Type of Building: Single - Family ( ) Duplex ( ) Multi - Family Commercial ( ) , Restaurant ( ) Other ( ) Date Received: OCT o s 2010 TOWN OF VAIL MECHANICAL PERMIT M ' N �, c. N A Divaion oJMovndin Man Fireplareand Chimney, Inc 7001 Highway 73, Evergreen, CO. 80439 Tel: (303) 670 -0658 / 674 -5377 Fax: (303) 679 -1592 office @MtnHP.com www.MtnHP.com 30 September 2010 To: Town of Vail - TOV Building Department 75 South Frontage Road Vail CO 81657 From: Jake T Johnson - President Contractor Registration # - 438 -M Ref (A): NFPA -211: National Fire Protection Association Standard 211 for Chimneys, Fireplaces, Vents and Solid Fuel - Burning Appliances (2010 Edition) Encl (1) Timberwolf Woodstove Installation Instructions — Cover page (2) Timberwolf Woodstove Installation Instructions — Page 46 / Specifications (3) Timberwolf Woodstove Installation Instructions — Page #10 / Clearances (4) Timberwolf Woodstove Installation Instructions — Page # 15 — Typical install (5) Simpson DVL Specifications Page (6) Color picture of existing fireplace and connector Mechanical Permit — Scope of Work Addendum Vail Racquet Club — Unit 1107 / Scott Walters Dates of operation — October 19 — 21 and Oct 26 — 28, 2010 Onsite VRC representative — Steve Loftus Onsite project supervisor — Nick Wallbank (MH &P) At the request of the Vail Racquet Club, we conducted a comprehensive Level I Inspection [in accordance with the professional standards set forth in Reference (A)] of the fireplace and chimney on April 9, 2010. The chimney inspection was conducted by chimney sweeps certified by the Chimney Safety Institute of America and the National Fireplace Institute. Our upcoming proposed operations are limited to: 1. Removal of single - walled stovepipe connector 2. Removal of unlisted freestanding wood fireplace 3. Installation of Timberwolf Model 2100 EPA - Certified Woodstove (see Encl 1 - 4) 4. Installation of Simpson DVL double - walled stovepipe connector — 6" interior diameter. Simpson DVL is UL Listed for 6" clearance to combustible materials (see Encl 5). No removal or replacement is being made to the chimney system. The woodstove and connector will be installed in strict accordance with all provisions of the manufacturer's Installation Instructions. Respectfully submitted — Jake Johnson / CSIA / NFI / FIR] 11 -11 -2010 Inspection Request Reporting Page 44 7 :49 am Vim, CO - City Of Requested Inspect Date: Thursday, November 11, 2010 Inspection Area: JRM Site Address: 4650 MEADOW DR VAIL UNIT 1107 A/P /D Information Activity: M10 -0221 Type: B -MECH Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: JRM Owner: WALTERS, SCOTT R - HORAK, KELLY L Contractor: I M I OUNTAIN MAN FIREPLACE AND CHIMNEY Phone: 303 - 679 -1601 Description: INSTALLATION OF A NEW WOODSTOVE Requested Inspection(s) f-t44 Item: 200 MECHb Requestor: Comments: 477 -3060 Assigned To: CGUNION Action: Time Exp: Inspection History Item: 200 MECH -Rough Item: 320 MECH- Exhaust Hoods Item: 330 MECH - Supply Air Item: 340 MECH -Misc. Item: 390 MECH -Final Requested Time: 01:30 PM Phone: Entered By: MHAEBERLE K I/ 41, Ix REPT131 Run Id: 12180