HomeMy WebLinkAboutM10-0224NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT
MWWO Vv
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
MECHANICAL PERMIT
AMF
Job Address: 4650 VAIL RACQUET CLUB DR VAIL
Location.....: UNIT 1117
Parcel No...: 210112404017
OWNER CRADDOCK, MARY K. 10/08/2010
5514 WESTERN AVE
CHEVY CHASE
MD 20815 -7122
APPLICANT MOUNTAIN MAN FIREPLACE AND C 10/08/2010 Phone: 303 - 679 -1601
7001 HIGHWAY 73
EVERGREEN
CO 80439
License: 438 -M
CONTRACTOR MOUNTAIN MAN FIREPLACE AND C 10/08/2010 Phone: 303 - 679 -1601
7001 HIGHWAY 73
EVERGREEN
CO 80439
License: 438 -M
Desciption: INSTALLATION OF A NEW WOODSTOVE
Valuation: $2,160.40
ALL TIMES
Permit #: M10 -0224
Project #: PRJ10 -0673
Status ...:
ISSUED
Applied..:
10/08/2010
Issued. .:
10/26/2010
Expires. .:
04/24/2011
#########««#««««««««««*««««#####««##*««««««««*«« # « « ### # # « ««* * « « ««« « « « *«« « « « #««« « FEE SUMMARY«««««««#«######*«««««««««««««««««#######««#«*#««««««*« * « ««« « « « ««# # # « «### # # #«# ##« ««« ««
Mechanical Permit Fee - -> $60.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $79.00
Plan Check — ------------ - - -> $15.00 Use Tax Fee - - - - -> $0.00 Additional Fees------ - - - - -> $0.00
Investigation ----------- — ---- > $0.00 TOTAL PERMIT FEE --- > $79.00
Total Calculated Fees - -> $79.00 Payments ------- -- ------ > $79.00
BALANCE DUE ------ $0.00
APPROVALS
Item: 05100 BUILDING DEPARTMENT
10/21/2010 JRM Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPEC ON SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0(
AM - 4 PM.
Signature of Owner or Contractor Date
nt
m e c h c a n i ca I_pe rm i t_041908
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: R100001691 Amount: $79.00 10/26/201010:44 AM
Payment Method: Check Init: LC
Notation: #13212 /
MOUNTAIN MAN FIREPLACE & CHIMNEY
-----------------------------------------------------------------------------
Permit No: M10 -0224 Type: MECHANICAL PERMIT
Parcel No: 2101- 124 - 0401 -7
Site Address: 4650 VAIL RACQUET CLUB DR VAIL
Location: UNIT 1117
Total Fees: $79.00
This Payment: $79.00 Total ALL Pmts: $79.00
Balance: $0.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
MP 00100003111100 MECHANICAL PERMIT FEES 60.00
PF 00100003112300 PLAN CHECK FEES 15.00
WC 00100003112800 WILL CALL INSPECTION FEE 4.00
• Complete Mechanical Room Floor Plan with Dimensions
• Combustion Air Duct Size and Location
• Flue detail or Vent size, location & termination
• Gas Piping layout including development length calculations
• Heat Loss Calculations
❑ Boiler size & efficiency
X _ Equipment Cut Sheets for Fireplaces /Log Sets
(Manutacturer's into showing make, model & approval li stin
Office Use:
Project #:
Building Permit #: JA_
Mechanical Permit #: W 10 — n�a
- `•la ` n Define Scope and Location of Work:
Contractor Inforltion: `5
£ E �
Company: ,
Company Address: 70d f' tTl all 1,()L(I,l / 3
City: State: �_ zip: Y 3N (use additional sheet if necessary)
Contact Name:
❑ Gas Piping Included
Contact Phone: 3D 3 / q • %f� ❑ Gas Piping by Others
❑ Wood to Gas Fireplace Conversion
E -Mail JAKE, 0- MTN f7 P. ( / D 9/ � ,( �
Town of Vail o tr t r Registration No.: p — / X Boiler Location:
j�� Interior ( ) Exterior ( ) Other ( )
Project Street Addrel
�0 ac 61, ri ///
(Number) (Street) \ / (Suite #)
V
Building /Complex Name: A\ L �_ 4 ' �V i
Number of Existing Fireplaces:
Cont ctor gnature (required)
Gas Appliances Gas Logs Wood /Pellet
Pr perty I formation -
Parcel #: Number of Proposed Fireplaces:
(For parc #, contact Eagle County Assessors Office at 970 - 328 -8640 or Gas Appliances Gas Logs Wood /Pellet
visit www.eaglecounty.us /patie) _
I Q /A :Type of Building:
Tenant Name: . �l,i J1 a C q '� ( / u-i2 Single-Family Duplex
Commercial roperties) 9 Y ( ) p ( )Multi - Family Commercial ( )
Owner Name: M q Cr,,Ldock ; Restaurant ( ) Other ( )
Date Received:
Complete Valuation for Mechanical Permit: (including fireplaces)
Mechanical $: -�KZj 6O0 • 7 d
00
_T
C: \cdev \forms \permits \building \mecha it 010110 '
OCT 0 5 2010
TOWN OF VAIL
MECHANICAL PERMIT
Boiler / Furnace & Fire lace ARRlications MUST include:
I � T �+�tc.,
�a�i
, Division ofMounrain Man Fireploeeand Chimney, Inc.
7001 Highway 73, Evergreen, CO. 80439
Tel: (303) 670 - 0658 / 674 - 5377 Fax: (303) 679 - 1592
office @MtnHP.com
www.MtnHP.com
30 September 2010
To: Town of Vail - TOV Building Department
75 South Frontage Road
Vail CO 81657
From: Jake T Johnson - President
Contractor Registration # - 438 -M
Ref (A): NFPA -211: National Fire Protection Association Standard 211 for Chimneys,
Fireplaces, Vents and Solid Fuel - Burning Appliances (2010 Edition)
Encl (1) Timberwolf Woodstove Installation Instructions — Cover page
(2) Timberwolf Woodstove Installation Instructions — Page #6 / Specifications
(3) Timberwolf Woodstove Installation Instructions — Page # 10 / Clearances
(4) Timberwolf Woodstove Installation Instructions — Page #15 — Typical install
(5) Simpson DVL Specifications Page
(6) Color picture of existing fireplace and connector
Mechanical Permit — Scope of Work Addendum
Vail Racquet Club — Unit 1117 / Mary Craddock
Dates of operation — October 19 — 21 and Oct 26 — 28, 2010
Onsite VRC representative — Steve Loftus
Onsite project supervisor — Nick Wallbank (MH &P)
At the request of the Vail Racquet Club, we conducted a comprehensive Level I Inspection
[in accordance with the professional standards set forth in Reference (A)] of the fireplace
and chimney on April 9, 2010. The chimney inspection was conducted by chimney sweeps
certified by the Chimney Safety Institute of America and the National Fireplace Institute.
Our upcoming proposed operations are limited to:
1. Removal of single - walled stovepipe connector
2. Removal of unlisted freestanding wood fireplace
3. Installation of Hearthstone Craftsbury Model EPA - Certified Woodstove (see Encl 1 - 4)
4. Installation of Simpson DVL double - walled stovepipe connector — 6" interior diameter.
Simpson DVL is UL Listed for 6" clearance to combustible materials (see Encl 5).
No removal or replacement is being made to the chimney system.
The woodstove and connector will be installed in strict accordance with all provisions of the
manufacturer's Installation Instructions.
Respectfully submitted — Jake Johnson / CSIA / NFI / FIRE
11 -11 -2010 Inspection Request Reporting Page 47
7:49 am Vail, CO - City Of
Requested Inspect Date: Thursday, November 11, 2010
Inspection Area: JRM
Site Address: 4650 VAIL RACQUET CLUB DR VAIL
UNIT 1117
A/P /D Information
Activity: M10 -0224 Type: B -MECH Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: Insp Area: JRM
Owner: CRADDOCK, MARY K.
Contractor: MOUNTAIN MAN FIREPLACE AND CHIMNEY Phone: 303 - 679 -1601
INC
Description: INSTALLATION OF A NEW WOODSTOVE
Requested Inspection(s)
Item: 200 MECH= kSgla�
Requestor:
Comments: 477 -3060
Assigned To: CGUNION
Action: Time Exp:
Requested Time: 03:00 PM
Phone:
Entered By: MHAEBERLE K
Inspection History
Item:
200 MECH -Rough
Item:
320 MECH- Exhaust Hoods
Item:
330 MECH - Supply Air
Item:
340 MECH -Misc.
Item:
390 MECH -Final
4 ,7- 0 V- A
[I I I d I �)
REPT131 Run Id: 12180