HomeMy WebLinkAboutB10-0393 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
.�
�owxo�y� •
Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657
p. 970.479.2139, f.970.479.2452, inpsections 970.479.2149
ADD/ALT MF BUILD PERMIT Permit #: B10-0393
Project #: PRJ10-0715
Job Address: 500 S FRONTAGE RD EAST VAIL Status. . : ISSUED
Location......: UNIT 416 Applied . . : 10/21/2010
Parcel No....: 210108117001 Issued. .. : 11/17/2010
Expires. ..: 05/16/2011
OWNER WREN ASSOC 10/21/2010
500 S FRONTAGE RD E
VAIL
CO 81657
APPLICANT NEDBO CONSTRUCTION 10/21/2010 Phone:970-845-1001
P.O. BOX 3419
VAIL
CO 81658
License:251-A
CONTRACTOR NEDBO CONSTRUCTION 10/21/2010 Phone:970-845-1001
P.O.BOX 3419
VAIL
CO 81658
License:251-A
Description:
REPAIR DAMAGE DONE BY FIRE/SMOKE EVENT.
Occupancy: Valuation: $60,000.00
Type Construction: Total Sq Ft Added: 0
..............�................�..,............�.�,.....«................,,......,.,. FEE SUMMARY ...__.,,...........,.......,,...........,...«.......................�,,...,,......,.
Building Permit Fee------> $713.75 Will Cal Fee---------------------> $4.00 Total Calculated Fees-------------> $2,181.69
Plan Check--------------------> $463.94 Use Tax Fee---------------------> $1,000.00 Additional Fees-----------------------> $0.00
Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES-------------> $2,181.69
Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00
Payments------------------------------> 52,181.69
Total Calculated Fees--------> $2,181.69 BALANCE DUE-----------------------> $0.00
,x..........................................,.,..........................,,,.,.........,.........,,..,,................................,....,�...,..................,�,,........,,...........
DECLARATIONS
I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate plot plan,and state that all the informatior
as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure
according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR iNSPECTION SHALL E MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM-4:00 P�A. i
, --�-- �-/�I
Signat re of Owne o ractor Date
N� � 6
Print Name
b Id_a It_con struction_pe rm it_041908
#wkwwww}fwwwwwrt4RwwfwR*wwww*1f*wM�wlwf**f�*fw*wMwwwwlflfw�wwww*YwwlwwRw4rt4f/w***w******fR********k*******w*******fR****fft�**#f1f#k!l444*****wwwflwRfwww*w*****R#**44�#1f+*wf*wwwwrtwR
APPROVALS
Permit#: 610-0393 as of 11-17-2010 Status: ISSUED
....................................................�.,.........,�..................,....,,,,,,...............,...............,.....,.�,,,,............................,�.,..,....,...
Item: 05100 BUILDING DEPARTMENT
11/16/2010 DRHOADES Action: AP OK TO APPROVE PER
MARTIN.
Item: 05110 ELECTRICAL REVIEW
Item: 05120 MECHANICAL REVIEW
Item: 05130 PLUMBING REVIEW
Item: 05600 FIRE DEPARTMENT
10/26/2010 mcgee Action: AP Install CO
detectors per IBC.
New smoke detector must be installed to replace detector
damaged by abatement.
•t(Rff�tL�Rf�4L1rfLLfi441�4Rt+RfiLfff44flff�1�1�1`41'f�+iF#1`4#41(44441nF1�1r1`4i(Li`i`kY`M�k�k#YrrtfYlrttrrttrY'ffrffit#+ww#Mw#k�rx�Rf*kwihFe#w4*l�RR4X***!!*41rt`f�1`41�*Rf*i(i�i�1`1`44�kY`�kW�A'MYertiPMrtrtfYNiFfi*iVx!lkfRf+flel�fl`M�YrYrrtfrtrtrtrtfrY'hA'h
See the Conditions section of this Document for any that may apply.
bld_a It_con stru ctio n_perm it_041908
www/N/�fi�+wk/kR+w*wwffw+++ww#wwwwxfMwfitx*ff*wwwkwxxxfR�t�wffx***wfRxfR#+##**f}f�f�ff�����#�fwfMkwwwwff�rtrtrtwwwwwwrtwwwwwwkw*t*aMRMflff����k1������fikMwf#fwwi#wwww*fl��ff�##�##fffwffw*w
CONDITIONS OF APPROVAL
Permit#: 610-0393 as of 11-17-2010 Status: ISSUED
.........................,...,.,......,...,,......,,.........�.................,..........,...........,.,,.,...........,....,.,.,....,,,,,,.......,............,,.,,...,,............,.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Cond: 14
(BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO
BE SEALED WITH AN APPROVED FIRE MATERIAL.
Cond: 1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
b Id_a It_constructio n_perm it_041908
********************+***********+*++*******************++********+**************************
TOWN OF VAIL, COLORADO Statement
+**********************************************************+********+++*******+*******+*****
Statement Number: R100001855 Amount: $2, 181.69 11/17/201009:54 AM
Payment Method: Check Init: LC
Notation: #16272 / NEDBO
CONSTRUCTION
-----------------------------------------------------------------------------
Permit No: B10-0393 Type: ADD/ALT MF BUILD PERMIT
Parcel No: 2101-081-1700-1
Site Address: 500 S FRONTAGE RD EAST VAIL
Location: UNIT 416
Total Fees: $2, 181.69
This Payment: $2, 181.69 Total ALL Pmts: $2,181.69
Balance: $0.00
********�****+******************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 713.75
PF 00100003112300 PLAN CHECK FEES 463.94
UT 11000003106000 USE TAX 4°s 1, 000.00
WC 00100003112800 WILL CALL INSPECTION FEE 4 .00
-----------------------------------------------------------------------------
���r � :�^� � , �� a , ,� u��� , a� + .� p , 75 Saut Fra�ta e Ro nt
De artment Qf Commun� Devel�o m
� � k �$ � � ,�* . � ; : `" � w� . . Va,il,.Colorado��,$�i �d �
„ � . . � � ��
,��„ 4� .
.
�� , �. �.����.; . ����,;; y����:°�g��+.,�
s .
, ill,
.,, ,
� �
, ° ,. .^. . . + � Y k ';.
� �
I S��'f�' �.. � ,,,� � .:,� � � � "� ���'��'� 3tl�'
� �"5 .. . .., a r 1- •...
k �
, e ��
., ,
, , . �. * a P , �
�r. ..„ ���d ,. � ����
� � �
� w
.a�, „
�.��... r. . � � .... ,.�.
�,,.... . �.... .. '.. .... .. ,,. � ' ,. . ..�
,.�.... ...: , .:, .
, , D� eldpmen � V. :
r �
" �pGVIiW � �"q:� ��. � �I �'�. �uV���� .k� �4,"�
'��,�?���'.'��� � M` . � '�� 4; �I I�rv
BUILDING PERMIT APPLICATION
Separate permits are required for electrical, plumbing, mechanical, fireplace, etc.
Project Street Address: Office Use:
s� 5. ��►�`v� �• � Proect#: ��a] 1�'' ����
(Number) (Street) (Suite#) �
Building/Complex Name: � �G. u►`�� DRB#:
Contractor Information: Building Permit#:�1 C}� �� [�
Company: �cd6o �ow5��nr��w�
.�� ,�x 3��y Detailed Scope and Location of Work:
Company Address:
,�A R.����- a.,,�.� ca� 6� �,�
City: UR�� State: �O Zip: �SIb��
1 f1 v►'��'�':
Contact Name: ���c.--- �C-��sbf� �'qt��C�r
Contact Phone: H 7�� �`�S ��� I�-1' �3C7 —
E-Mail �djj�c G��u•�'"� (use additional sheet if necessary)
Town of V ' ontractor Registrati n No.: � �$� Work Class:
t � New( ) Addition ( ) Remodel( ) Repair(x) Other( )
X �-
Contractor Signature equir ) Work Type
Property Information Interior(,�) Exterior( ) Both ( )
Parcel#: Z 1O1 ^0''dI ' E?(TD'l
(For parcel#,contact Eagle County Assessors Office at 970-328-8640 or Type of Building:
visit www.eaglecounty.us/patie) Single-Family( ) Duplex( ) Multi-Family�)
Lot#: Block# Subdivision: ("�'�� �� 1-n�`+� Commercial( ) Other( )
Tenant Name: Does a Fire Alarm Exist? Yes(,�) No O
Owner Name: Monitored Alarm? Yes(�) No( )
Does a Sprinkler System Exist? Yes( ) No(�()
#&Type of Existing Fireplaces: Gas Appliances(X)
Valuations(Labor&Materials)
Gas Log ( ) Wood/Pellet( ) Wood Burning ( )
Building: $
#&Type of Proposed Fireplaces: Gas Appliances(J()
Plumbing: $ Gas Log ( ) Wood/Pellet
p �� CC� €�° C:a -
Electrical: $
Date Received:
Mechanical(including Fireplace): $ o�� �y �o�o
Total: � ��� �� TQWN OF VAIL
�'�I 81. �9�
C:\cdev\forms\permits\building�residential_buil ding�ermit_O 10110
vpi�arRF``�`�
� :%"_.,,�,_
��"�Ra N�;,g£,,�`�' Vail Fire Department
,.__�_
Asbestos Testing &Abatement Requirements
Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex-
posure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regu-
lations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements
at the contact info listed below.
When is asbestos testing reauired?
ANY building projects disturbing more than these threshold levels of building materials require asbestos testing:
One- and Two-Family Dwellings: 30 square feet
All Others: 160 square feet
Asbestos testing results must be provided with your application for a building permit.
Tests which identify POSITIVE results at more than 1% require abatement by a State-certified and Vail-registered abate-
ment contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the
Town of Vail before the building permit will be issued
Project Checklist
My project falls into the category checked below:
� Will not disturb more than the threshold limits identified above.
� Tested negative, or at 1% or below (2 copies of test results included)
� Tested positive at more than 1%, requires abatement (2 copies of test results included)
Tips&Facts:
• Even recent construction projects may include asbestos-containing materials, so buildings of�age require testing.
. The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit
Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus,
much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce
of many asbestos-containing product categories was set aside and did not take effect." - CDPHE
Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development,
75 S Frontage Rd, Vail, CO3 81657.
Town of Vail Contact: State of Colorado Contact:
David Rhoades, Fire Inspector Colorado Department of Public Health
Vail Fire Department and Environment
75 S Frontage Rd Asbestos Compliance Assistance Group
drhoades@vailgov.com 303-692-3158
970-477-3454 asbestos@state.co.us
www.vailgov.corn www.cdpne.state.ca.us
c:\cdev\forms\permits\bui lding\comm_bui Iding�ermit_01 O 110
l� � �_Lj \°! �
D
�C�` 19 ZOiO
iOWN C)F VA1L
.
, �I D � � 93
:� ;r:
,
DS Consulting, Inc.
Final Clearance Air Monitoring Report
The Wren - Unit 416
S00 S Frontage Rd, Vail, Colorado 81657
Presented To:
Mr. Nicolas A. Gonzales
Project Manger
MDR Corporation
10650 Irma Dr,Unit 15
Northglenn, CO 80233
Performed&Prepared By:
Mr. Steve Shurtliff
DS Consulting, Inc.
PO Box 6864
Avon, CO 81620
(303) 378-1544
Project Details:
Project Number: 2925
Conducted: October 26, 2010
The Wren -Unit 416 �� `V7 �,-,
,�
�, ��', ��-�, �_�', \/ L�
fi OCT 2�' 2010
�
TOWN OF VAIL
EXECUTIVE SUMMARY
On October 26, 2010, Mr. Steve Shurtliff with DS Consulting, Inc. (DSC) conducted a final visual
inspection, performed aggressive clearance air monitoring, and analyzed clearance air-quality samples
via Phase Contrast Microscopy (PCM) for an asbestos abatement project encompassing unit 416 of The
Wren located at 500 S Frontage Rd,Vail, Colorado.
Services were provided at the request of Mr. Nicolas A. Gonzales with MDR Corporation in support of
asbestos abatement activities being conducted to remove +�- 112ftz of asbestos-containing drywall and
+�- 582ftz of asbestos-containing acoustical ceiling from a full containment encompassing unit 416 of The
Wren in Vail, Colorado. Monitoring locations and frequencies were determined by Mr. Steve Shurtliff;
having EPA and State of Colorado accreditation No. 15413. PCM analysis was also performed by Mr.
Shurtliff(see Appendix B for certification).
DSC's scope of work for this project included performing a final visual inspection and collection and
analysis of aggressive final air quality samples by NIOSH 582-trained personnel for determination of
airborne asbestos (as total�bers) concentrations in identified areas. DSC is a participant in the Industrial
Hygiene Proficiency Analytical Testing (IHPAT) program with laboratory ID No. 188987 and has a rating
of Proficient. The abatement project passed the final visual inspection and the analytical results of all
samples collected were below the clearance criteria of 0.01 fibers/cubic centimeter (f/cc) (seeAppendixA
for Air Sample Analysis).
PROJECT INFORMATION
� General Abatement Contractor (GAC) • Air Monitoring Specialist/Analyst
MDR Corporation Mr. Steve Shurtliff
• GAC Project Supervisor • Date Conducted
Mr. Nicolas A. Gonzales October 26, 2010
• Project Location • Final Clearance Sample Results
The Wren - Unit 416 See Appendix A
500 S Frontage Rd,Vail, Colorado
• Cerdfications
• Project Contact See Appendix B
Mr. Nicolas A. Gonzales
2
ti
PROJECT INTRODUCTION
On October 26, 2010, Mr. Steve Shurtliff with DS Consulting, Inc. (DSC) conducted a final visual
inspection, performed aggressive clearance air monitoring, and analyzed clearance air-quality samples
via Phase Contrast Microscopy (PCM) for an asbestos abatement project encompassing unit 416 of The
Wren located at 500 S Frontage Rd,Vail, Colorado.
Services were provided at the request of Mr. Nicolas A. Gonzales with MDR Corporation in support of
asbestos abatement activities being conducted to remove +�- 112ftz of asbestos-containing drywall and
+�- 582ftz of asbestos-containing acoustical ceiling from a full containment encompassing unit 416 of The
Wren in Vail, Colorado. Monitoring locations and frequencies were determined by Mr. Steve Shurtliff;
having EPA and State of Colorado accreditation No. 15413. PCM analysis was also performed by Mr.
Shurtliff(see Appendix B for certification).
SCOPE OF WORK
DSC's scope of work for this project included performing a final visual inspection and collection and
analysis of aggressive final air quality samples by NIOSH 582-trained personnel for determination of
airborne asbestos (as total fibers) concentrations in identified areas. DSC is a participant in the Industrial
Hygiene Proficiency Analytical Testing (IHPAT) program with laboratory ID No. 188987 and has a rating
of Proficient. The abatement project passed the final visual inspection and the analytical results of all
samples collected were below the clearance criteria of 0.01 fibers/cubic centimeter (f/cc) (see AppendixA
for Air Sample Analysis).
AIR MONITORING
Air-quality samples were collected utilizing a modified NIOSH 7400 Method, whereby samples were
collected on 25-millimeter (mm) mixed-cellulose, ester-membrane filters with 0.45-micron pore size and
analyzed via Phase Contrast Microscopy(PCM) as per the customer's requirements.
Sample Collection - PCM samples, when applicable, were collected on 25-millimeter (mm) mixed-
cellulose, ester-membrane filters with 0.45-micron pore size with an effective collection area of 385 mm.
All filters were pre-assembled by the manufacturer in three stages, conductive sampling cassettes with
extension cowls.
Air samples were collected at an average flow rate 12.5 liters per minute (L/m) using Thomas high-
volume pumps with a minimum of 1,200 liters being collected. Flow rates were collected at the
beginning and at the end of the sampling period utilizing an airflow rotameter calibrated against a
primary-flow calibration instrument. Start times and stop times were recorded for all sampling periods.
A field blank and lab blank were also collected and analyzed along with the five (5) clearance samples.
PCM Sample Analysis Method - PCM samples were analyzed according to a modified NIOSH 7400
Method—A Counting Rules—although samples were collected on 25-mm mixed-cellulose, ester-
membrane filters with 0.45-micron pore size and analyzed via PCM. Air sample results contained in this
report have been calculated with blank sample corrections.
3
� �
APPENDIX A - AIR SAMPLE RESULTS
� � , � � � � . -
� � � � �
� - �
CL-1 Hi vol. Kitchen 12.5 8:40a 10:30a 110 1364 4.0 100 0.002
CL-2 Hi vol. Livin Room 12.5 8:40a 10:30a 110 1364 4.0 100 0.002
CL-3 Hi vol. Livin Room 12.5 8:40a 10:30a 110 1364 2.5 100 0.001
CL-4 Hi vol. Hallwa 12.5 8:40a 10:30a 110 1364 3.5 100 0.001
CL-5 Hi vol. Bedroom 12.5 8:40a 10:30a 110 1364 2.0 100 0.001
CL-lb n a Lab Blank n a n a n a n a n a 0 100 0.000
CL-fb n a Field Blank n a n a n a n a n a 0 100 0.000
APPENDIX B - CERTIFICATIONS
.- t,. , ,
-�� Y� - � �fi�,� �°�,.
.:.� � w c..��, �'. . '�
� � � a� �, �'�� �t ��� f��.�'��; ,"��1��"�t._..5 '� �' ;, �`��'�s '��;� 1.°.�ti���.
C�: "� ._..y�, � �c t' �pw � .1 94'x. �� n. � �d�
a r` �9�N°.�_vt X- �"it ♦ A Jr iM �+ �. lr w ,t : ` �t A,'�
r,` ..ew,yn,a,� �,♦ rc�.p, k�`�s �
� . , �..,;;. _ .. , , , ., y ':, �
,°��`�; STAT� OF COLORADO � ;{ �
. s ,�� �
� :1ti13H:ti 1�()S "+ � ..
k , —
C E[2"T'l I�IC:�7�lU\* +. .� . �
� � —
�` 'v � r �
��» ` �„i.,�.�, i�.,, ����,„�r�„n����ii.-o��� ��� z �
4' y
:�d�a� u�ixrsni� �F LL�� � ,� i
:` �ir Fatluoon C unlrcd[>ir�aiun '� '�. � Q
�'k .`:J'µ ; � � . y
. i �' " - v "� T I
yv �'^ l�tu -ytiii�...t;w� �� �p S� .. _ "si Z j�
r C� [ £ < — � ^""
�� � �
�� ' �� Stl�(tihUrTI1lT �„�,`�� � �e s . r j x �_
C C y 5 3 ad, �_�C C�i,�
l�ertilicalion�u:i�tl) {� .: P� C � —' y ji'2 �•• ���
;, `� ,�y���,,� � j �U $ :� � :..I u Gs / �
.' ,.�� hss nx�tbe rcyuvenKOts ul 25 �•50?.C'.R 5.und,�ir Qu�hty Cumrol � ' .,, !i (S' ,� . � ;� �' �Y � �I4
� '£ Contmnsion Regul¢tr<n\o$ 1 an ki nnd i hci�by ccnilirJ hs thi . �V "— � �I
w�� � etau ot l�le.tud. �t.w i,.l�.ow mE dn:rZ�lfnc•. � �`. l�r' S+,�
�" "�.?� �� r��: <,
� � �
Air Ai�anitorin�tinccialls!* "r ' L �`
r :! =;
� + ..
�' I..ud 4,II::W9 j� �
��'��. � � ��
�,'.. E�plmrr�:Y'II:SLII /•�s , � �;k. � �
� �;1,,'2`fdtt�tx`��,� �,s' � �i`�?o�
w.�.',a�reowr...., ,t �,.:
' .�, � � I
�' �no..up��b�.uw.r�.�y�.�.....iar...�rr�.,�+«�rre»w T ��5 Y
- ..��t rwMr�iW+
��n r. � O °.7� ..
}�� �.� ,.� ,� ... . .�, �R� � r�ik��� � �L�,. i,�Mpk
��44 �a' K� c -�iF''�r y.� X 'h y� +�? 'A+ y� ■ ..
� yti. �
. ..i i .t, P �. � d t�6.. 44 i �. �.. ..,.. �.
� �
�. t`` " r .�.�cKrl` '�i?.� . ..�. , +1 . *
�"':... � ....=�:t. -.:�.,�'.�.'�...'�.�`�;�.�..�' µ�.,u�.,ji�.�....::,',,.✓,';�_„..�. {<._ �..' � ..,
4
Asbestos Inspection and Sampling Report
500 S. Frontage Rd. East#416, Vail, eolarado 81657
Presen ted to:
Mr. George Snyder
Nedbo Construction
P.O. Box 3419
Vail, CO 81658
(970) 845-9979
Performed& Prepared by:
Mr. Nate Skinner
DS Consulting, Inc.
PO Box 6864
Avon, CO 81620
(303) 917-8081
Project Details:
DSC Project #: 2861
Conducted: September 30, 2010
. �`'�
� ��������� �
� �
�
EXECUTIVE SUMMARY
On September 30, 2010, Mr. Nate Skinner of DS Consulting, Inc. (DSC) performed a limited inspection and
asbestos sampling at 500 S. Frontage Rd. East #416, Vail, Colorado, in order to identify potentially
hazardous friable and non-friable asbestos-containing materials (ACM) within a portion of the above-
referenced, single-family residence recently affected by a fire. The Colorado Department of Public Health
and Environment's (CDPHE) Regulation S, Part B defines an asbestos-containing material (ACM) as a
material containing more than 1% asbestos.
Mr. Skinner performed asbestos bulk-sampling of plaster (surfacing material) and drywall (surfacing
material) in a total of nine (9) locations within the residence (see Appendix A for sample locations). All
nine (9) bulk-samples were analyzed by Aerobiology Laboratory Associates, Inc. (NVLAP #200860-0)
with three (3) laboratory results being positive for asbestos between 5% and 8% Chrysotile (see
Appendix C for laboratory results). Additionally, three samples of drywall reported trace amounts of
Chrysotile and were point counted at or less than.25% Chrysotile.
The following sampled materials were found to contain asbestosgreater than 1% (ACM):
� �
� � j � • �
1 1 • .� .� �. �. � � � I
� � t �
�
DC1-1 Drywall& Hallway Ceiling Surfacing Friable <1000ftz Damaged 5%Chrysotile
Texture Material
DC1-2 Drywall& Hallway Ceiling Surfacing Friable <1000ftz Damaged 5%Chrysotile
Texture Material
DC1-3 Drywall& Hallway Ceiling Surfacing Friable <1000ftz Damaged 8%Chrysotile
Texture Material
*Quantities are approximations and subject to field verification.
2
PROJECT OVERVIEW
I. Introduction
A limited inspection and bulk-sampling for ACM was conducted at 500 S. Frontage Rd. East #416, Vail,
Colorado, by Mr. Skinner on September 30, 2010, at the request of Mr. George Snyder with Nedbo
Construction. Mr. Skinner is a Colorado State Certified Building Inspector; having EPA Accreditation
#16227 (see Appendix B for certificate). The purpose of the inspection was to identify, sample and assess
potentially hazardous friable and non-friable ACM within the unit.
II. Structural Design
The structure is a single level unit within the multi-unit,Wren condominium complex.
III. Sampling and Analytical Procedures
The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building
Inspector qualified by experience, education and training in the recognition of potential ACM and
approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a
limited number of bulk-samples being collected within the residence.
The inspection, assessment and sampling were performed in accordance with Environmental Protection
Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of
concern and the collection and analysis of representative bulk-samples of suspect material.
Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not
broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be
located in these and other inaccessible areas.
Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of
each homogeneous area (HA), were collected according to the guidelines published as Environmental
Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections
2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the
following criteria:
1. The distribution of the suspect material throughout the HA.
2. The suspect material's physical characteristics and application.
3. Random sampling patterns determined for each HA.
Suspect materials sampled and analyzed should be considered to be representative of materials in each
HA if they exhibit similar physical characteristics and the application of the sampled material can be
correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the
EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993)
and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the
bulk-samples was performed on the"date reported," as listed in the bulk-sample analysis report.
3
IV. Notes on Report Format
Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were
divided into three classifications:
1. Surfacing Material: sprayed or troweled onto structural building member.
2. Thermal System Insulation (TSI): any type of pipe, boiler,tank, or duct insulation.
3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles,
insulation, and finishing materialse
Condition assessments were performed by the accredited inspector at the time of inspection. Condition
assessments are listed in the following section. Ratings of "good," "damaged," and "significantly
damaged" are meant to indicate the overall condition of the material.
A material in "good" condition has no visible damage or deterioration, or showing only very limited
damage or deterioration.
A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered,
water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the
damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or
debris similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence. A material in "significantly damaged" condition has one or more of the following
characteristics:
• The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized).
• One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or
showing adhesive failure.
• Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris
similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence.
Response-action recommendations for asbestos-containing HAs are listed in the section VII.
Recommendations may be for more than one HA, if materials are alike. Recommendations are either
"general" or "immediate." An immediate recommendation indicates the presence of asbestos greater
than 1% within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly.
A general recommendation indicates asbestos does not exist greater than 1% within the bulk-sample, or
a bulk-sample in the same HA, and no further abatement activities are required for removal of the
material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for
asbestos greater than 1% unless it is analyzed by the point-count method to be less than 1%.
V. Inspector Comments
Asbestos was identified during the bulk-sampling conducted at 500 S. Frontage Rd. East #416, Vail,
Colorado. A total of nine (9) bulk-samples were collected from the above-referenced residence. Three
(3) bulk-samples tested positive,greater than 1% for asbestos.
■ Asbestos was identified in the ceiling drywall popcorn texture(surfacing material) sample DC1-1
at 5% Chrysotile
4
■ Asbestos was identified in the ceiling drywall popcorn texture (surfacing material) sample DC1-2
at 5% Chrysotile
■ Asbestos was identified in the ceiling drywall popcorn texture (surfacing material) sample DC1-3
at 8% Chrysotile
VI. Homogeneous Area Descriptions
The following section contains sampled HA descriptions and sample locations. Percent-asbestos content
for each sample indicated can vary depending on sample locations, homogeneity of the materials, and
type of application. The following samples were collected from the residence at 500 S. Frontage Rd. East
#416, Vail, Colorado, on September 30, 2010. The quantities are approximations and are subject to field
verification:
� � • . . � . . � � � � . . � � . �
Sample#: PL1-1 Sample#: PL1-2
Sample Description: Plaster Sample Description: Plaster
Sample Location: Fireplace Wall Sample Location: Fireplace Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: <1,OOOftz Material Quantity: <1,OOOft2
Material Condition: Damaged Material Condition: Damaged
Physical Description (layers): White perlitic Physical Description (layers): White perlitic
laster; White ranular laster w white aint laster; White ranular laster w white aint
Asbestos Content(layers): Negative; Negative Asbestos Content(layers): Negative; Negative
Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII
� � • . . � . . , . � � � � . . � , . , . �
Sample#: PL1-3 Sample#: DW1-1
Sample Description: Plaster Sample Description: Surfacing Material
Sample Location: Fireplace Wall Sample Location: Hallway Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: <1,OOOft2 Material Quantity: <1,OOOft2
Material Condition: Damaged Material Condition: Damaged
Physical Description (layers): White perlitic physical Description (layers): White tape; White
plaster; White granular plaster w/gray paint paint; White texture;White joint compound;
White tan dr all
Asbestos Content(layers): Negative; Negative Asbes�tos Content(layers)o Negative; Negative;
<.2 5/o Ch sotile; <.2 5/o Ch sotile; Ne ative
Recommendations: GENERAL- See Section VII Recommendations: GENERAL- See Section VII
5
1 1 • . . � i . � 1 1 • . . � � . �
Sample#: DW1-2 Sample#: DW1-3
Sample Description: Surfacing Material Sample Description: Surfacing Material
Sample Location: Hallway Wall Sample Location: Hallway Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: <1,OOOftz Material Quantity: <1,OOOftz
Material Condition: Damaged Material Condition: Damaged
Physical Description (layers): White tape;White Physical Description (layers): White tape; White
paint; White texture;White joint compound; paint; White texture;White joint compound;
White tan dr all White tan d all
Asbestos Content(layers): Negative; Negative; Asbestos Content(layers): Negative; Negative;
<.25% Ch sotile; .25% Ch sotile; Ne ative .25% Ch sotile; <.25% Ch sotile; Ne ative
Recommendations: GENERAL- See Section VII Recommendations: GENERAL- See Section VII
� � � . . � , . 1 � � • . . � � - 1
Sample#: DC1-1 Sample#: DC1-2
Sample Description: Popcorn Ceiling Texture Sample Description: Popcorn Ceiling Texture
Sample Location: Hallway Ceiling Sample Location: Hallway Ceiling
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: <1,OOOftz Material Quantity: <1,OOOftz
Material Condition: Damaged Material Condition: Damaged
Physical Description (layers): White/tan drywall; Physical Description (layers): White Plaster;
White foamy texture w/white paint White/tan drywall; White foamy texture w/
white aint
Asbestos Content(layers): Negative; 5% Asbestos Content(layers): Trace Chrysotile;
Ch sotile Ne ative; 5% Ch sotile
Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII
6
1 / � . . � � • . �
Sample#: DC1-3
Sample Description: Popcorn Ceiling Texture
Sample Location: Hallway Ceiling
Material Classification: Surfacing Material
Material Quantity: <1,OOOft2
Material Condition: Damaged
Physical Description (layers): White tape; White
laster;White foam texture w white aint
Asbestos Content(layers): Negative; Trace
Ch sotile; 8% Ch sotile
Recommendations: IMMEDIATE - See Section VII
VII. Recommendations
IMMEDIATE:
The laboratory results of the potential ACM sampled at 500 S. Frontage Rd. East #416, Vail, Colorado, on
September 30, 2010, indicate that three (3) bulk-samples of drywall and popcorn ceiling texture collected
from the hallway ceiling were reported as positive for asbestos between 5% and 8% Chrysotile and three
(3) bulk samples of drywall point-counted at or less than .25% Chrysotile.
If the above-referenced ACM is to be removed from the residence and the total quantity exceeds any of
the regulatory trigger levels of 50 linear feet on pipes, 32 square feet on other surfaces, or the volume
equivalent of a 55-gallon drum, a Colorado-licensed asbestos abatement contractor is required to
perform the removal, including formal notification to the Colorado Department of Public Health and
Environment prior to the abatement of the ACM.
7
APPENDIX A
SAMPLE LOCATIONS
Fireplace
Wall
PW1-1
PW1-3 PW1-2
�
Living
Room
DCl-1 DC1-2
DC1-3
Hallway Bedroom
DW1-1
DW1-2
DW1-3
8
APPENDIX B
CERTIFICATION
� �� ��� � � �� � �� �
�, �
� t '�� �
,�
J ;�
� � ,. �: �sJ 1��L1���.[' A,...��L���.�1,V�.! � » #
� �` � �
(
� �������, �
ES �;
; �
''; ����IFI�A'��?l�I� ��
� . , . ,,., �� .- � 4' .
p CrsTarado De�trkttie�af`Pttikrlic ET�=at1�
t � �� and�w�r�inszt�nt ��_ ` '� �
A��P�2lut�is-��l I?tv�Sicsn =w f
� � � �
;.,.
'i7us sert}�es that � �
�; � ,': i����l�ll ����I1�C �
�� � � . �� ��� � ,�� � ��
�ertifica#ion 1\tr.1��?7 �;, �.
"a ` � �'
', l�as met tb�re�ir�ments af Za��7-��'1��.L��S�as�c�t�ir t;�ualit��Cc�ntroT i, '� '�
� ' '` Cc�mmtssi�rn R�i�tion No,�>�'act B,s�r€�f is�Zereby c�ified l�y t�e � j
� � �,: s�t�c�f Cvl�rado in�e f�rlt��u�discipltne:-:� �1
� � � �
- �, ;; Ba�idin� i�tsp��it�� �
� �
[ssued; 2t6/2fli0 �
� �xptres on� 2J6/24x� �
, ' � _� <
"' � �il�.- a
, •
. ,..zea, .R�roa�,aa�ve � °+ � �.:
. ... ;. � ��.. ..�� � j
'.7342r c�tr�ilcwtr:s wrt7d aeXp�.r`tk t!apax�rssien oJa euirerut?i:�isio,+ripprovsrtYrrte7x�ror�ss �
cmrF,/7earioeinr7��d3ut}rtleerpce3Jtt�nbows ; .....
� � ;
t� �14 �^ �� �
� . �:.�. �� �
r
'��...��-�°�`� ��..�,.�-�*��.�,,,--`'+�..�...�;. .��,��*.,�,,��*. n.w_e.--'
APPENDIX C
LABORATORY ANALYSIS
9
��.�►���t�t��t��c:�►c.:�y �c�c�rzarc�rzy
--.,,,,,,_---� ASSOCtATES, tNCC}RPt}RATED
�� CONSUITtNG LAB012ATORY
Certificate of Analysis
13949 W.Colfax Ave
Suite 20�
Lakewood,CO 80401
303.2323746
vwvw.aerobioloyy.nTt
Client Name DS Consutling,Inc. ��n��aa Date Collected: 09/30/10
Street address 5366 Flatrock Ct. �( d Date Received: 09/30/]0
City,State ZIP Morrison,CO 80465 Date Analyzed: 10/O1/10
Attn: Nate Skinner NVLAP Lab Code 200860-0 Date Reported: 10/O1/10
Client Project Name: 500 S.Frontage Road E.#416 Vail 81657 Project ID: ]07293
Job ID:
Test Requested: 3002,Asbestos in Bulk Samples
Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physicai Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments esbo La ers% area% area% com osition
107293-1A White Perlitic Plaster N 2,10% Negative 100 P
PW1-1
107293-1B White Granular Plaster w/White Paint N 2,90% Negative 100 Q
107293-2A White Perlitic Plaster N 2,5% Negative 100 P
PWl-2
107293-2B White Granular Plaster w/White Paint N 2,95% Negative 100 Q
107293-3A White Perlitic Plaster N 2,10% Negative 100 P
PW1-3
107293-3B White Granular Plaster w/Grav Paint N 2,90% Negative 100 Q
98%
107293-4A White Tape N 5,3% Negative CELL 2
107293-4B White Paint N 5,3% Negative 100
DW1-1
POSITIVE
107293-4C White Texture N 5,7% TRACE CHRY 100 G
POSITIVE
107293-4D White Joint Compound N 5,10% TRACE CHRY 100 G
� �c:"%S��"�,l�� �.as..f�'�'._-
���
Paul Knappe
Laboratory Analyst
• ,�
�'#, -� �- `~ � ,.._
am ump reys
Asbestos Laboratory Supervisor
A=Amosite
AC=Actinolite
AN=Anthophyllite
CHRY=Chrysotile
CR=Crocidolite
TR=Tremolite
Trace=Less Than 1%
CELL=Cellulose
MW=Mineral Wool
FBG=Fiberglass
SYN=Synthetic
WO=Wollastonite
NTR=Non-Asbestiform TR
NAC=Non-Asbestiform AC
FT=Fibrous Talc
AH=Animal Hair
Q=Quartz
C=Carbonates
V=Vermiculite
G=Gypsum
M=Mica
T=Tar
P=Perlite
O=Organic
B=Binder
OP=Onaques
��►E��t�►t��v�ca►c�y v�c�otzart�r�y
:�--„�,,,—� ASS4ClATES, INCORPORATED
��� corusu�r��vc�aac��aAro�v
Certifcate of Analysis
13949 W.Colfax Ave
Suite 205
Lakewood,CO 80401
303.2323746
www.aerobioloav.net
T
Client Name DS Consutling,Inc. �����;� Date Collected: 09/30/10
Street address 5366 Flatrock Ct. � Date Received: 09/30/10
City,State ZIP Morrison,CO 80465 Date Analyzed: 10/O1/10
Attn: Nate Skinner NVLAP Lab Code 200860-0 Date Reported: 10/O1/10
Client Project Name: 500 S.Frontage Road E.#416 Vai181657 Project ID: 107293
Job ID:
Test Requested: 3002,Asbestos in Bulk Samples
Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments es/no La ers% area% area% com osition
15%
DW1-1 107293-4E White/Tan Drywall N 5,77% Negative CELL 85 G
107293-SA White Paint N 5,2% Negative 100
98%
107293-SB White Tape N 5,3% Negative CELL 2
POSITIVE
DW1-2 107293-SC White Texture N 5,7% TRACE CHRY 100 G
POSITIVE
107293-SD White Joint Compound N 5,10% TRACE CHRY 100 G
15%
107293-SE White/Tan Drywall N 5,78% Negative CELL 85 G
107293-6A White Paint N 4,5% Negative 100
98%
107293-6B White Tape N 4,10% Negative CELL 2
DW1-3
POSITIVE
107293-6C White Texture N 4,40% TRACE CHRY 100 G
POSITIVE
107293-6E White Joint Compound N 4,45% TRACE CHRY 100 G
,-
Ci��'������:._.
Paul Knappe
Laboratory Analyst
,�' p,.
�� � _,� _ � � _..�.w -__
am ump reys
Asbestos Laboratory Supervisor
A=Amosite
AC=Actinolite
AN=Anthophyllite
CHRY=Chrysotile
CR=Crocidolite
TR=Tremolite
Trace=Less Than 1%
CELL=Cellulose
MW=Mineral Wool
FBG=Fiberglass
SYN=Synthetic
WO=Wollastonite
NTR=Non-Asbestiform TR
NAC=Non-Asbestiform AC
FT=Fibrous Talc
AH=Animal Hair
Q=Quartz
C=Carbonates
V=Vermiculite
G=Gypsum
M=Mica
T=Tar
P=Perlite
O=Organic
B=Binder
OP=Opaaues
��vE���a��t��c�►c�� �uc�r�arc.�rzy
--.�,�,,,,-�.�„� ASSOCIATES, !'IVCC�RPORATED
��� coMSU�rin►c�ssc>�aAro�v
Certi�cate of Analysis
13949 W.Colfax Ave
Suite 205'
Lakewood,CO 80401
3032323746
www.aerobioloav.net
Client Name DS Consutling,Inc. ���� �, Date Collected: 09/30/10
Street address 5366 Flatrock Ct � Date Received: 09/30/10
City,State ZIP Morrison,CO 80465 � Date Analyzed: ]0/O1/10
Attn: Nate Skinner NVLAP Lab Code 200860-0 Date Reported: 10/01/10
Client Project Name: 500 S.Frontage Road E.#416 Vail 81657 Project ID: 107293
Job ID:
Test Requested: 3002,Asbestos in Bulk Samples
Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments es/no La ers% area% area% com osition
15%
107293-7A White/Tan Drywall N 2,30% Negative CELL 85 G
DC1-1 POSITIVE
107293-7B White Foamv Texture w/White Paint N 2,70% 5%CHRY 95 C
POSITIVE
107293-8A White Plaster N 3,20% TRACE CHRY 100 G
IS%
DC1-2 107293-8B White/Tan Drywall N 3,20% Negative CELL 85 G
POSITIVE
107293-SC White Foamv Texture w/White Paint N 3,60% 5%CHRY 95 C
98%
107293-9A White Tape N 3,15% Negative CELL 2
POSITIVE
DC1-3 107293-9B White Plaster N 3,25% TRACE CHRY 100 G
POSITIVE
107293-9C White Foamv Texture w/White Paint N 3,60°/a 8%CHRY 92 C
�- s
Li'.t.c���`�✓�__.
Paul Knappe
Laboratory Analyst
, �, ff
� � t � _...._<._.
c. ,,` � - _..._..
.� ..
am ump reys
Asbestos Laboratory Supervisor
A=Amosite
AC=Actinolite
AN=Anthophyllite
CHRY=Chrysotile
CR=Gocidolite
TR=Tremolite
Trace=Less Than 1%
CELL=Cellulose
MW=Mineral Wool
FBG=Fiberglass
SYN=Synthetic
WO=Wollastonite
NTR=Non-Asbestiform TR
NAC=Non-Asbestiform AC
FT=Fibrous Talc
AH=Animal Hair
Q=Quartz
C=Carbonates
V=Vermiculite
G=Gypsum
M=Mica
T=Tar
P=Perlite
O=Organic
B=Binder
OP=Opaques
�AEr�obir�lca+�y l.�bc�rz��rc�r�y
�--�.` ASSOCIATE5,INCORPORATEQ
�� C�NSUL'TING 1AE30RATORY Certificate of Analysis
13949 W.Colfa�c Ave
Suite 205
Lakewood,CO 80401
303.2323746
www.aerobiologv.net
DS Consutling Inc. � Date Collected: 09/30/10
5366 Flatrock Ct. j��a�� Date Received: 09/30/10
Monison,CO 80465 Date Analyzed: 10/01/10
Nate Skinner NVLAP Lab Code 200860-0 Date Reported: 10/O1/10
Client Pro,ject Name: 500 S.Frontage Road E.#416 Vail 81657 Project ID: 107293
Job ID:
General Notes
♦ Negative indicates no asbestos was detected;the method detection limit is 1%.
♦ Trace or"<1"indicates asbestos was identified in the sample,but the concentration is less than the method detection limit of 1%.
♦ All regulated asbestos minerals(i.e.chrysotile,amosite,crocidolite,anthophyllite,tremolite,and actinolite)were sought in every layer of each sample,but only those asbestos
minerals detected are listed.Amosite is the common name for the asbestiform variery of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the
asbestiform variety of the mineral reibekite.
♦ Tile,vinyl,foam,plastic,and fine powder samples may contain asbestos fibers of such small diameter(<0.25 microns in diameter)that these fibers cannot be detected by PLM.
For such samples,more sensitive analytical methods(e.g.TEM,SEM,and XRD)are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM
floor tile analysis is accepted under the NESHAPS regulations.
♦ These results are submitted pursuant to Aerobiology Laboratory Associates,Inc.'s current terms and conditions of sale,including the company's standard warranty and limitation
of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.
♦ Unless notified in writing to retum the samples covered by this report,Aerobiology Laboratory Associates,Inc.will store the samples for a minimum period of thirty(30)days
before discarding. A shipping and handling chazge will be assessed for the return of any samples.
Notes Reauired bv NVLAP
♦ This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST,or any agency of the Federal Government.
♦ This test report relates only to the items tested or calibrated.
♦ This report is not valid unless it bears the name of a NVLAP-approved signatory.
♦ Any reproduction of this document must include the entire document in order for the report to be valid.
13949 W.Colfax Ave.Suite 205,Lakewood CO 80401,3032323746
���v��zc�u�t��t�c�y ��carz�rc�r�y
--,,,�—.,,,� ASSOCIATES, INCt7RP{)RATED
'"�� corusu�T��vc�ec�H�roa�r
Certificate of Analysis
13949 W.Colfax Ave
Suite 205
Lakewood,CO 80401
303.2323746
www.aerobioloav.ne,t
Client Name DS Consutling,Inc. ������n Date Collected: 09/30/10
Street address 5366 Flatrock Ct. a Date Received: 09/30/10
City,State ZIP Morrison,CO 80465 Date Analyzed: 10/04/10
Attn: Nate Skinner NVLAP Lab Code 200860-0 Date Reported: 10/04/10
Client Project Name: 500 S.Frontage Road E.#416 Vai181657 Project ID: 107293
Job ID: POINT COiJNT
Test Requested: 3002,Asbestos in Bulk Samples
Method: Polarized Light Microscopy/Dispersion Staining(PLM),Method for the Determination of Asbestos in Bulk Building Materials.EPA-600/R-93/116,July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments esbo La ers% area% area% com osition
107293-4C White Texture N 100% <.25%CHRY
DWl-1
107293-4D White Joint Compound N 100% <.25%CHRY
107293-SC White Texture N 100% <.25%CHRY
DW1-2
107293-SD White Joint Compound N 100% .25%CHRY
107293-6C White Texture N 100% .25%CHRY
DW]-3
107293-6D White Joint Compound N 100% <,25%CHRY
r //'g �
G�'a7'-C"'`....� ^��" �i��i-�-����:_�
Paul Knappe
Laboratory Analyst
_t'",�_� � .��_.
... . �„ ., x--� -.....
� ��' �r
e,. �
am ump reys
Asbestos Laboratory Supervisor
A=Amosite
AC=Actinolite
AN=Anthophyllite
CHRY=Chrysotile
CR=Crocidolite
TR=Tremolite
Trace=Less Than 1%
CELL=Cellulose
MW=Mineral Wool
FBG=Fiberglass
SYN=Synthetic
WO=Wollastonite
NTR=Non-Asbestiform TR
NAC=Non-Asbestiform AC
FT=Fibrous Talc
AH=Animal Hair
Q=Quartz
C=Carbonates
V=Vermiculite
G=Gypsum
M=Mica
T=Tar
P=Perlite
O=Organic
B=Binder
OP=Onaaues
12 -17 -2010 Inspection Request Reporting Page 10
7:44 am Vail, CO - CitV Of
Requested Inspect Date: Friday December 17, 2010
Site Address: 500 S FRONTAGE RD EAST VAIL
UNIT 416
A/P /D Information
Activity: B10 -0393 Type: A -MF
Const Type: Occupancy:
Owner: WREN ASSOC
Contractor: NEDBO CONSTRUCTION
Description: REPAIR DAMAGE DONE BY FIRE /SMOKE EVENT.
Reauested Inspection(s
Item: 90 BLDG -Final
Requestor: DBO C NSTRUCTION
Assigned To: J GON
Action: Time Exp:
Iteml` VNEuDB ecial Inspect-pro gress rept
uestor: CONST U IOIV ied To:
Action: Time Exp:
VA
Inspection Histo
Item: 501 PW -)
Item: 226 FIRE
Item: 10 BLDG
Item: 504 PW -1
Item: 502 PW -1
Item: 20 BLDG•
Item: 21 PLAN -
Item: 410 Spec
Item: 22 PLAN -
Item: 30 BLDG
Item: 50 BLDG
Item: 60 BLDG
l
NOTIFICATION
NG
t
r�
vJ
rept
;k Nail ** Approved **
11/20/10 Inspector: Martin
Comment:
Item: 70 BLDG -Misc.
Item: 535 DIA - 30 DAY REMINDER
Item: 536 DIA - SITE /LANDSCAPING
Item: 420 Special Inspect-final rept
Item: 503 PW -Final Driveway Grade
Item: 515 PW- Public Improvement
Item: 516 PW- Warranty Acceptance
Item: 90 BLDG -Final
Sub Type: AMF
Use:
Phone: 970 - 845 -1001
Status: ISSUED
Insp Area:
Requested Time: 02:45 PM
Phone: GEORGE 977 -0330
Entered By: SBELLM K
Requested Time: 02:30 PM
Phone: GEORGE 977 -0330
Entered By: SBELLM K
Action: AP APPROVED
REPT131 Run Id: 12304