HomeMy WebLinkAboutF10-00890 . Department of Community Development it x,44 75 South Frontage Road Vail, Colorado 81657 � , Tel: 970 - 479 -212$: Fax: 970 - 479 -2452 ►'� 1 Web: www.vailgov.com l w. t a 'e Co n t � �k' FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: 100 E. Meadows Dr. (Number) (Street) Building /Complex Name (Suite #) Vail Village Inn Plaza Ph - III Contractor Information: Company: Western States Fire Protection Company Address: 7026 S. Tuscan Way City: Centennial State: CO Zip : 80112 Office Use: Project #: f -I R'sa) �0�021 Building Permit #: ) o -- oaay Sprinkler Permit #: P I ©-- ci s 9 Lot #: Block # Subdivision: Detailed Description of Work: New piping and sprinkler heads installed and sized for Hydraulic Contact Name: Joe Hayden demand of modified system layout Contact Phone: 303 - 549 -8979 (use additional sheet if necessary) E -Mail joe.hayden @wsfp.us Detailed Location of Work: Work will be preformed in Town of Vail Contractor Registration No.: 338 -S New Woo Restaurant main level X Contractor Signature (required) Property Information Parcel #: 210108261004 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Rick Woo - Restaurant Owner Name: Staufer Commercial LLC Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler $: $7,200.00 Does a Monitored Fire Alarm Exist? Yes (v) No ( ) Does a Sprinkler System Exist? Yes (v ) No ( ) Work Class: New ( ) Addition ( ) Remodel (v) Repair ( ) Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial ( ) Restaurant ( ,) Other ( ) Date Received TOWN OF VAIL nECCEO'sIEn �( OCT 26 2010 U) O1- Feb -10 FIC)- 0088 1� Western States 1 Fire Protection Co. PLOt;ctusy .&e¢ acrd Material Submittal FOR WOO RESTAURANT 100 East Meadows Drive Vail, CO 81658 New Tenant Finish Prepared by: Jeff Hagan Project Manager Western States Fire Protection Co. 7026 S. Tucson Way Centennial, CO 80112 Phone (303) 792 -0022 Fax (303) 792 -9049 Cell (303 -549 -9553 Email jeff.hagan @wsfp.us WSFP #CS1006 October 25, 2010 MATERIAL INDEX "Because of the current escalation occurring with steel, WSFP reserves the right to substitute pipe as required to meet project schedules. Description Model Manufacturer I. Flow & Hydraulic Information A. Vail Water Flow Data/Adjustment Chart B. Calculation Printouts, Woo Restaurant II. Sprinkler Heads A. Standard Spray Quick Response Semi - Recessed Sprinkler F!FR Reliable B. Standard Spray Quick Response Dry Pendants DS -1 Tyco C. Standard Spray Quick Response Horizontal Dry Sidewall DS -1 Tyco III. Pipe — 1 -1/4" and smaller threaded A. Black Schedule 40 Pipe ASTM A 795 Varies" IV. Pipe — 1 -1/2" and larger grooved A. Black Schedule 10 Pipe ASTM A135 Varies" V. Cast Iron Fittings Varies Varies" VI. Pipe Hangers (Per NFPA 13) A. All Thread Rod Fig. 100 Tolco B. Adjustable Ring Hanger Fig. 200 Tolco C. Top Beam "C" Clamp w /Locknut Fig. 68 Tolco D. Surge Retainer Fig. 25 Tolco VII. Grooved Fittings A. Grooved Firelock Fittings Varies Victaulic B. Grooved Firelock Rigid Couplings Style 005 Victaulic C. Mechanical T, Bolted Branch Outlet Style 920/922 Victaulic "Because of the current escalation occurring with steel, WSFP reserves the right to substitute pipe as required to meet project schedules. + t Hydraulic Overview e� Job Number: CS1006 - WOO -REST Reoort Descriolion: Ordinary GrouD I Job Jae N-1 N N,,, Erpmaer Ja! Nvr„a: P— F FN neaaa.r s smia caniM1CaaoMi —N„mea. wm,aa 2 N N city s sWY Z Zip coEa J Joe si,e VAIL C CO 8 81658 System p A Area of A{pliwr n r D.R— q sw..u.r Dw R Ran. saran 5.6 K- Factor 18.15 at 10.505 2 250.00 cowrge Par swinMlr w wm- a sOM1i�ara CalWSlatl 121.00' 1 12 syrrn PnauA Darrlartl s sy.— Fbw DaRw 60.826 2 248.73 Tm Dern— P P.... R. Supplies C Check Point Gauges Node Flow m Hose Flow(aom) S Static (psi R Residual(psi) I Identifier Pressure(psi) K- Factor(K) Flow m 1 523.50 250.00 1 150.000 7 76.600 Brian Hauser Western States Fire Protection Co. Nicet Level III Registration #121351 OCT 2 1 2010 Sprinkler . tern LayU Signature_ CS1006 WOO- REST.cad S Supply at Node 1 (523.50, 250.00, 150.000, 76.600) 200 - - -- 180 160 tatic Pressure 150.000 140 -- a _-------- -------------- 1 120 too a 80 5 523.50 7 76. 248.73 60.826 _ 4 498.73 with hose streams 40 S System d demand c curve r YSL 20 J ......... . ........ Y TD cL I%W 400 500 600 700 800 900 1 1000 Water flow, gpm 0 M.E.P.CAD, Inc. AutoSPRINKO VR7 v7.1.7 10/25/2010 5:03:12PM Page 1 +� Hydraulic Summary Job Number. CS 1006 - WOO -REST Job D­, Egxwer CS1006 ' N_: WOO RESTAURANT ­1 CaNficatgNLica N.— 100 EAST MEADOWS DR. Add— I dm sne c� st. Lp— DrAwNpNm VAIL CO 81658 CS1006 WOO- REST.cad System Remote Area (s n Dwwtl g SWY w De o—u Y — suft 5.6 K -Factor 18.15 at 10.505 Ordinary Group I WOO -REST MowASowwiwN3— Dwtlb Ano of AppipAEm 250.00 0.150gpm/ft' 900.00ft' (Actual 1006.48ft') AtllbW Mow suPFw. wmew m sp id— CAkule- Cow N, 3,—W Node FI w m 12 121.00ft' AubPesk P—AL Pn Fn RsppY Ma(s) Ad* To Abet Re Arr To Mow soeeme 250.00 spurn FY Demons Tad w.,w ft*i J ( v Mow AN—) 248.73 498.73 ,Awime.n wwoYe upe.r.>. Y �pP. 0.000 Alwo—WWJ1yA Gr 23.78 between nodes 2 and 7 nY.i vw—Y u.a.. Grpueo volume u ty of wel Pipes volume — 0t y of Dry Pipee 253.86gal 0.18gal Supplies Hose Flow Static Residual @ Flow Available @ Total Demand Required Safety Margin Node m (psi) si m (psi) pm (psi) (psi 1 250.00 150.000 76.600 523.50 82.895 1 498.73 60.826 22.068 COrllraCtOf - r : ',• i�fi IM Cony b NwMYi 22 CanYp Nww JEFF HAGAN cenYOl TnY PM Nwne d cav,«ror WESTERN STATES FIRE PROTECTION vhane 303 -792 -0022 � 115 Anbew 1 7026 S TUSCON WAY FM 303 - 792 -9049 Aaenw 2 e jeff.hagan @wsfp.us D"y st zip c. wwsn. CENTENNIAL CO 80112 www.wsfp.com 1�, 0 M.E.P.CAD, Inc. 11 AutoSPRINK® VR7 v7.1.7 10/25/2010 5:03:20PM Page 2 111 ummary Of Outflowing Devices �j Job Number: CS1 006 - WOO-REST Report Description: Ordinary Group I Device Actual Flow m Minimum Flow m K- Factor K Pressure (psi Sprinkler 333 22.08 18.15 5.6 15.540 Sprinkler 334 20.73 18.15 5.6 13.700 S rinkler 337 20.69 18.15 5.6 13.649 Sprinkler 338 22.18 18.15 5.6 15.681 Sprinkler 339 23.87 18.15 5.6 18.164 Sprinkler 335 18.35 18.15 5.6 10.736 Sprinkler 336 18.77 18.15 5.6 11.234 Sprinkler 346 20.48 18.15 5.6 13.381 Sprinkler 347 21.78 18.15 5.6 15.122 Sprinkler 348 23.29 18.15 5.6 17.297 Sprinkler 351 18.15 18.15 5.6 1o.505 Sprinkler 352 18.38 1 18.15 5.6 10.771 c:> Most Demanding Sprinkler Data !A © M.E.P.CAD, Inc. 4A AutoSPRINK® VR7 v7.1.7 10/25/2010 5:03:29PM Page 3 do Job Number: CS1006 - WOO -REST Report Description: Ordinary Group I Node Elevation Foot Fittings Pressure si Dischar e m 34 -7'-0 T(26'-4), LtE 11' -3 /z 59.057 2 9' -2 P010' -0 46.281 3 8'-7 PO 5'-0 24.374 4 9' -5Yz T T-0 22.010 5 8' -7 PO 5'-0 25.388 6 9' -5'/2 T T-0 22.483 7 8' -7 T 10' -0 29.296 8 8' -7 PO F-0 27.944 9 9' -5 E 2'-0 24.807 10 8' -7 PO F-0 27.841 11 9' -5 E 2' -0 26.165 35 8' -7 PO 6'-0 27.767 165 9' -5 T T-0 27.040 12 8' -7 E 5'-0 22.169 13 9' -5' /z P010 - -0 21.637 14 8' -7 PO F-0 22.413 15 9' -5 T F-0 19.789 16 8' -7 PO 5'-0 23.063 36 9' -5 21.345 17 9' -5 T 5'-0 16.728 18 9' -5'/z T T-0 14.932 19 9' -5Yz T 5'-0 14.647 20 9' -5Y: T 5'-0 16.647 21 9' -51/2 T 5'-0 19.845 199 9' -5 E 3'-0 14.713 22 9' -5Yz PO 5'-0 14.358 23 9' -5Y: T 6'-0 14.288 24 9' -5Yz PO 5'-0 13.897 25 9' -5Yz T 6'-0 14.170 26 9' -5 PO 5'-0 14.172 27 9' -5Yz T 6'-0 15.928 28 9' -5 T F-0 11.267 29 9' -5 T 5'-0 11.455 30 9' -5'h T F-0 16.039 31 9' -5Yz T F-0 18.882 32 9' -5'/2 T 5'-0 19.021 33 9' -5' /z T 6'-0 20.927 214 9' -5 E T-0 21.915 333 8'-4 S - 15.540 15.540 22.0 334 8'-4 S r - 13.700 13.700 20.7 337 8'-4 S r - 13.649 13.649 20.6 338 8'-4 S r - 15.681 15.681 22.1 339 8'-4 S r - 18.164 18.164 23.8 335 8'-4 S r - 10.736 10.736 18.3 336 8'-4 S r - 11.234 11.234 18.7 346 8'-4 S r - 13.381 13.381 20.4 347 8'-4 S r - 15.122 15.122 21.7 348 8'4 S r- 17.297 17.297 23.2 351 7'-4 1 S r- 10.505 10.505 18.1 352 7 - 41 S r- 10.771 10.771 18.3 & 0 M.E.P.CAD, Inc. 11 AutoSPRINKO VR7 v7.1.7 10/25/2010 5:03:33PM Page 4 Y Job Number: CS 1006 - WOO -REST Report Description: Ordinary Group I Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K•Factor Pt Pn Fittings Eq. Length Total Length Summary GM ••••• Route 1..... DR 1.0490 Q =18.15 6.74 C =120 0.108742 11' -5'/ Pf 1.684 351 28 7'-4 9' -512 q =18.15 K =5.6 10.505 11.267 Spr(- 10.505) 2E(2' -0) 44 15' -51 -0.921 Pv BL 1.0490 Q =36.50 13.55 C =120 0.396002 V -7 3 o Pf 2.629 28 24 9'-5/2 9' -5% 11.267 13.897 PO(5' O) 5'- 6' -7 Pe Pv CM 1.3800 Q =14.00 3.00 C =120 0.017694 9' -51 Pf 0.273 24 25 9' -512 9' -5,2 13.897 14.170 T(6' -0) 6' 15' -5, Pe Pv CM 1.3800 Q =1.19 0.26 C =120 0.000185 2' -7 Pf 0.002 25 26 9' -5,2 9' -5'/2 14.170 14.172 T(6' -0) 6' 8' -71/ Pe Pv CM 1.3800 Q =38.34 8.22 C =120 0.114061 9'-4'/ Pf 1.757 26 27 9' -5 V -5,2 14.172 15.928 T(6' -0) 6' 15'4'/ Pe Pv BL 1.0490 Q =15.98 5.93 C =120 0.085948 8'41/ Pf 0.719 27 20 9' -5 9 -512 15.928 16.647 8'41/ Pe Pv BL 1.0490 Q =38.16 14.17 C =120 0.429955 8'- Pf 5.836 20 6 9' -5'/ 9' -5/2 16.647 22.483 T(5' -0) 5' 13'- Pe Pv RN 1.0490 Q =38.16 14.17 C =120 0.429955 0' -10'/ Pf 2.526 6 5 9'5 8' -7 22.483 25.388 PO(5' O) 54 5' -101 0.379 Pv CM 2.0670 Q= 157.45 15.05 C =120 0.217590 7' -11'/ Pf 3.908 5 7 8' -7 8' -7 25.388 29.296 T(10' -0) 10*4 17' -111 Pe Pv CM 2.0670 Q= 248.73 23.78 C =120 0.507052 14' Pf 17.235 7 2 8' -7 9' -2 29.296 46.281 2E(5' -0), PO(10' -0) 20'- 34'- Pe -0.250 Pv FM 4.2600 Q= 248.73 5.60 C =120 0.014981 64' -11 Pf 5.771 2 34 9' -2 -7'-0 46.281 59.057 3E(13' -2), 3LtE(7'- 10 GV(2' -71/2), 2T(26' -4), BFP(- 2.905), LtE(1 V -3%) 126-04 191' -31 Pe 7.005 Pv FM 6.3570 Q= 248.73 2.51 C =120 0.002133 58' -11 Pf 0.174 34 1 -7'-0 - 10'-8% 59.057 60.826 2LtE(11' -3 %), S 22' -7, 81'-6, Pe 1.596 Pv ea Route 2••••• DR 1.0490 Q =18.35 6.81 C =120 0.110959 2' -2'/ Pf 1.019 335 28 8'4 9' -5 q =18.35 K =5.6 10.736 11.267 Spr(- 10.736) E(2' -0), T(5' -0) 7'- 9' -2, Pe -0.488 Pv ei••••• Route 3••••• DR 1.0490 Q =18.38 6.82 C =120 0.111287 10' -5 Pf 1.606 352 29 7'-4 9' -5,2 q =18.38 K =5.6 10.771 11.455 Spr(- 10.771) 2E(2' -0) 4'4 14' -51/ Pe -0.921 Pv BL 1.0490 Q =37.15 13.79 C =120 0.409127 V -7 1 / Pf 2.717 29 26 9' -5 9' -51/2 11.455 14.172 PO(5' O) 5'- 6' -7 Pe Pv 40 ••••• Route 4••••• DR 1.0490 Q =18.77 6.97 C =120 0.115710 V -1 1 / Pf 0.709 336 29 8'-4 9' -512 q =18.77 K =5.6 11.234 11.455 Spr(- 11.234) T(5' -0) 5' V -11/ Pe -0.488 Pv w••••• Route 5••••• DR 1.0490 Q =20.48 7.60 C =120 0.136028 T -9 1 / Pf 1.464 346 22 8'-4 9' -5'/ q =20.48 K =5.6 13.381 14.358 Spr(- 13.381) E(2' -0), PO(5' -0) 7'- 10' -91 Pe -0.488 Pv CM 1.3800 Q =27.91 5.99 C =120 0.063409 2'-71/ Pf 0.355 22 199 9' -5 9' -5 14.358 14.713 E(3' -0) 3'4 5'-7/ Pe CM 1.0490 Q =27.91 10.36 C =120 0.241094 8'-41 Pf 2.016 199 17 9' -51/2 9 -5 14.713 16.728 8' -41 Pe Pv CM 1.0490 Q =49.99 18.56 C =120 0.708557 6'51 Pf 4.617 17 36 9'5,2 9' -5,2 16.728 21.345 6'-6, Pe Pv CM 2.0670 Q =49.99 4.78 C =120 0.026052 V -2 Pf 0.292 36 13 9'-5 9' -51/2 21.345 21.637 PO(10' -0) 10'4 11' -2/ Pe Pv RN 2.0670 Q =49.99 4.78 C =120 0.026052 0' -10, Pf 0.153 13 12 9' -512 8' -7 21.637 22.169 E(5' -0) 5'4 5' -10'/ Pe 0.379 Pv ,A 0 M.E.P.CAD, Inc. 'aAutoSPRINK® VR7 v7.1.7 10/25/2010 5:03:41PM Page 5 'Al Hydraulic Analysis Job Number: CS1006 - WOO -REST Report Description: Ordinary Group I Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K- Factor Pt Pn Fittings Eq. Length Total Length Summary CM 2.0670 Q =49.99 4.78 C =120 0.026052 9'4'/ Pf 0.244 12 14 8' -7 8' -7 22.169 22.413 9' -4/ Pe Pv CM 2.0670 Q =85.79 8.20 C =120 0.070758 9' -2Y Pf 0.650 14 16 8' -7 8' -7 22.413 23.063 9' -2/ Pe Pv CM 2.0670 Q =85.79 8.20 C =120 0.070758 8'-69 Pf 1.311 16 3 8' -7 8' -7 23.063 24.374 2E(5' -0) 10' 18'-6' Pe Pv CM 2.0670 Q= 119.29 11.41 C =120 0.130210 T -9 Pf 1.014 3 5 8' -7 8' -7 24.374 25.388 7' -9/ Pe Pv v••••• Route 6••••• DR 1.0490 Q =20.69 7.68 C =120 0.138545 3'-8 Pf 1.486 337 19 8'-4 9' -5 /z q =20.69 K =5.6 13.649 14.647 Spr(- 13.649) E(2' -0), T(5' -0) 7'- 10' -8/ Pe -0.488 Pv BL 1.0490 Q =33.50 12.44 C =120 0.337925 12' -9/ Pf 7.362 19 4 9' -5/z 9' -5/: 14.647 22.010 2E(2' -0), T(5' -0) 9'- 21' -9 Pe Pv RN 1.0490 Q =33.50 12.44 C =120 0.337925 0' -109 Pf 1.985 4 3 9' -5'% 8' -7 22.010 24.374 PO(5' -0) 5 - 5' -10'/ Pe 0.379 Pv o••••• Route 7••••• DR 1.0490 Q =20.73 7.69 C =120 0.139025 5'-41 Pf 1.720 334 18 8'-4 9' -5' /z q =20.73 K =5.6 13.700 14.932 Spr(- 13.700) E(2' -0), T(5' -0) 7'- 12'-0 Pe -0.488 Pv BL 1.0490 0=35.80 13.29 C =120 0.382066 7'-8' Pf 4.856 18 15 9' -5'/ 9' -5% 14.932 19.789 T(5' -0) 5'- 12' -8/ Pe Pv RN 1.0490 0=35.80 13.29 C =120 0.382066 0' -10 Pf 2.245 15 14 9' -5'/: 8' -7 19.789 22.413 PO(5' O) 5' 5' -10/ Pe 0.379 Pv o••••• Route 8••••• DR 1.0490 Q =21.78 8.08 C =120 0.152320 2' -2 Pf 1.405 347 30 8'-4 9' -5 /2 q =21.78 K =5.6 15.122 16.039 Spr(- 15.122) E(2' -0), T(5' -0) 7'- 9' -2 Pe -0.488 Pv CM 1.3800 Q =44.13 9.47 C =120 0.147984 17' -1 Pf 2.981 30 32 9' -5'/: 9' -5/: 16.039 19.021 E(3' -0) T4 20' -1'/ Pe Pv CM 1.3800 Q =51.28 11.00 C =120 0.195358 3'- Pf 1.906 32 33 9' -5'/: 9' -5 /s 19.021 20.927 T(6' -0) 6' 9'- Pe PV BL 1.0490 0=26.61 9.88 C =120 0.220772 21' -8'/ Pf 5.238 33 11 9' -5/: 9' -5'% 20.927 26.165 E(2' -0) 2'4 23' -8 Pe Pv RN 1.0490 Q =26.61 9.88 C =120 0.220772 0' -10 Pf 1.297 11 10 9' -5Y: 8' -7 26.165 27.841 PO(5' -0) 5'- 5' -103 Pe 0.379 Pv CM 2.0670 Q =51.28 4.90 C =120 0.027311 3'- Pf 0.103 10 8 8' -7 8'-7 27.841 27.944 T-1 Pe Pv CM 2.0670 Q =91.29 8.73 C =120 0.079379 7' -0/ Pf 1.352 8 7 8' -7 8' -7 27.944 29.296 T (10' -0) 10' 17' -0 Pe Pv 4�••••• Route 9••••• DR 1.0490 Q =22.08 8.20 C =120 0.156217 3'-8'/ Pf 1.676 333 17 8'-4 9' -5/: q =22.08 K =5.6 15.540 16.728 Spr(- 15.540) E(2' -0), T(5' -0) 7' 10' -8 Pe -0.488 Pv ®••••• Route 10••••• DR 1.0490 Q =22.18 8.23 C =120 0.157526 2' -2 Pf 1.453 338 20 8'-4 9' -5 /z q =22.18 K =5.6 15.681 16.647 Spr(- 15.681) E(2' -0), T(5' -0) 7' 9' -2'/ Pe -0.488 PV 40 ••••• Route II..... DR 1.0490 Q =23.29 8.65 C =120 0.172480 5' -0/ Pf 2.073 348 31 8'-4 9' -5/: q =23.29 K =5.6 17.297 18.882 Spr(- 17.297) E(2' -0), T(5' -0) 7' 12'-0/ Pe -0.488 Pv BL 1.0490 Q =16.14 5.99 C =120 0.087536 1 V4 Pf 0.963 31 21 9' -5 /x 9' -5% 18.882 19.845 1 V4 Pe Pv BL 1.0490 Q =40.01 14.85 C =120 0.469305 8'- Pf 4.963 21 9 9' -5% 9' -5% 19.845 24.807 E(2' -0) 2'4 10'- Pe Pv t1&i 0 M.E.P.CAD, Inc. in AutoSPRINK® VR7 v7.1.7 10/25/2010 5:03:41 PM Page 6 41: � Hydraulic Analysis � i re Job Number: CS1006 - WOO -REST Report Description: Ordinary Group I Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K- Factor Pt Pn Fittings Eq. Length Total Length Summary RN 1.0490 Q =40.01 14.85 C =120 0.469305 0' -101/ Pf 2.757 9 8 9' -5 8' -7 24.807 27.944 PO(5' -0) 5' 5' -10 Pe Pv 0.379 , .b ..... Route 12••••• DR 1.0490 Q =23.87 8.86 C =120 0.180463 5' -01/ Pf 2.169 339 27 8'-4 9' -51/2 q =23.87 K =5.6 18.164 19.845 Spr(- 18.164) E(2' -0), T(5' -0) 7' 12'-0% Pe Pv -0.488 �••••• Route 13••••• CM 1.3800 Q =24.66 5.29 C =120 0.050440 0' -10'/ Pf 0.347 165 35 9' -5 8' -7 27.040 27.767 PO(6' O) 6'-C 6' -10% Pe Pv 0.379 CM 2.0670 Q =24.66 2.36 C =120 0.007052 10'-7 Pf 0.075 35 10 8' -7 8' -7 27.767 27.841 10'-7 Pe Pv v••••• Route 14••••• CM 1.3800 Q =24.66 5.29 C =120 0.050440 10'- Pf 0.988 33 214 9' -51/2 9' -5 20.927 21.915 T(6' -0) E(3' -0) 9'4 19'- Pe Pv CM 1.0490 Q =24.66 9.16 C =120 0.191785 21' -8 Pf 5.126 214 165 9' -51/2 9' -5% 21.915 27.040 T(5' -0) 5'- 26' -8 Pe Pv o••••• Route 15••••• BL 1.0490 Q =7.15 2.65 C =120 0.019397 2' -1 Pf 0.139 31 32 9' -5 9' -5 18.882 19.021 T(5' -0) 5'- 7' -1 Pe Pv �••••• Route 16••••• CM 1.3800 Q =22.35 4.80 C =120 0.042049 2' -7 Pf 0.111 27 30 9' -5K 9' -5 15.928 16.039 2' -7 Pe Pv 4W ..... Route 17••••• CM 1.3800 Q =22.50 4.83 C =120 0.042552 3' -2 Pf 0.391 24 23 9' -5 9' -51/2 13.897 14.288 T(6' -0) 6'4 9' -21/ Pe Pv CM 1.3800 Q =7.43 1.59 C =120 0.005476 6'- Pf 0.070 23 22 9' -5 9' -5%2 14.288 14.358 T(6' -0) 6'- 12'- Pe Pv 60 ••••• Route 18••••• BL 1.0490 Q =15.07 5.59 C =120 0.077102 8'-41/ Pf 0.645 23 18 9' -5 9' -51/2 14.288 14.932 8'-4/, Pe Pv do ••••• Route 19••••• BL 1.0490 Q =12.81 4.76 C =120 0.057087 8' -4 Pf 0.477 25 19 9' -5'/2 9' -5 14.170 14.647 8'4 Pe Pv Equivalent Pipe Lengths of Valves and Fittings (C =120 only) / Actual Inside Diameter l Schedule 40 Steel Pipe Inside Diameter k \ ° J = Factor C Value Multiplier Value Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 L 0 M.E.P.CAD, Inc. %I AutoSPRINK® VR7 v7.1.7 10/25/2010 5:03:41 PM Page 7 40 Hydraulic Analysis Job Number: CS1006 - WOO -REST Report Description: Ordinary Group I Pipe Type Diameter Downstream Elevation Upstream Flow Velocity HW_C____ _________ ___ __ Friction Los Discharge K- Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary Pipe Type Legend Units Legend Fittings Legend Diameter Inch ALV Alarm Valve Elevation Foot AngV Angle Valve Flow gpm b Bushing Discharge gpm BaIV Ball Valve Velocity fps BFP Backflow Preventer Pressure psi BV Butterfly Valve Length Foot C Cross Flow Turn 90' Friction Loss psi /Foot cplg Coupling HWC Hazen - Williams Constant Cr Cross Run Pt Total pressure at a point in a pipe CV Check Valve Pn Normal pressure at a point in a pipe DeIV Deluge Valve Pf Pressure loss due to friction between points DPV Dry Pipe Valve Pe Pressure due to elevation difference between indicated points E 90° Elbow Pv Velocity pressure at a point in a pipe EE 45° Elbow Eel 11'/.° Elbow Ee2 22'/,° Elbow f Flow Device Id Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node IT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer /Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap LM, © M.E.P.CAD, Inc. AutoSPRINKO VR7 v7.1.7 10/25/2010 5:03:41 PM Page 8 is lHydraulic Graph Job Number: CS 1006 - W00 -REST Supply at Node 1 200 -- 180 160 - Static Pressure 150.000 140 120 t00 a 523.50 76.600 248.73 @ 60.826 Ah 498.73 with hose streams 40 S fstem demand curve 20 0 g 700 00 200 400 600 800 900 1000 300 500 Water flow, gpm Supply at Node 1 soot: P —. 150.000 RW P-- 523.50 @ 76.600 A.4" R— a Tim.-' - 82.895 @ 498.73 248.73 @ 60.826 Symm 498.73 @ 60.826 LM,. V M.E.P.CAD, Inc. a AutoSPRINK® VR7 v7.1.7 10/25/2010 5:03:47PM Page 9 VAIL FIRE DEPARTMENT CONVERSION FACTORS FOR COMPUTATION OF AVAILABLE FIRE FLOWS FROM FIRE HYDRANTS The following conversion factors need to be applied to the results of fire flow tests conducted within the Town of Vail. The conversion factor is applied to the results to compensate for "peak demand." The conversion factors are listed for each month in which a fire flow test is conducted. The factor shown as Q d is multiplied against the gallons per minute flowing P1-1), represented by " Q " in Freeman's formula Q = (29.71 d x Qpkd' CONVERSION FACTORS (Qpkd) Month in which Flow Test was conducted ....... Factor (Qpkd) Jan uary .............. .........................60.89% F ebruary ............. .........................58.66% March................ .........................74.79% April ................ .........................53.32% May .................. .........................56.21% June ................. .........................81.16% July ........... ............................... 100% August ............... .........................83.23% September ............ .........................68.12% October .............. .........................46.99% November ............. .........................38.06% December ............. .........................82.22% FLOWTESTINFO TA PRESSUR -- - - 15ppp RESIDUAL PR RE N FLOW JPITOT 1111 TEST CONDUCTED BY WSFP 6 WITNESSED BY EAGLE RIVER WATER 6 VFESON OCT 215T.2010 VAIL FIRE DEPARTMENT FIREFLOW ADJUSTMENTS 1114 GPM ■ 46 99% - 47 GPM 1114 - 297■ 6.23 +R x 46, 9" {g 1472 1 46991 129 71116 25y • 76.6 PSI A DJUSTED F LOW TEST WO _S TATIC PRES i I RESIDUAL PRESS -__ FLOW 5235wm_ EXAMPLE: A flow test is conducted in March. The results indicate a static pressure of 135 PSI, residual pressure 90 PSI, with 1600 GPM flowing. The flow rate of 1600 GPM is multiplied by the conversion factor (Q�pk ) for March, 74.79% (1600 GPM x 74.79% _ 1197 GPM). NOTE: Trie 1600 GPM has been reduced from 1761 GPM by the coefficient of discharge, .90. Recompute the pressure using Freeman's formula, by replacing the value for Q (1600), with the new Q value (1197), to derive the new derated residual pressure (1 P in order to allow for peak demand (1197 = 29.7 x d f P). Given d is a constant (6.25), the new pressure is = [(1197/29.71)/6.25] = 44.55 P WOO RESTAURANT, 100 EAST MEADOWS DR. VAIL CO 81658 I m I inbi � Model F1 FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model F1 FR Recessed Sprinkler Types Recessed Pendent R ecessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) 5. NYC BS &A No. 587 -75 -SA 6. Meets MIL- S -901C and MIL -STD 167 -1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93 -E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model F1 FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- 00 C CD W C 34 Recessed Pendent (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. Bulletin 136 Rev.M Model F1 FR Model F1 FR Recessed Quick Response Sprinklers The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread Orifice Size K Factor Sprinkler Approval Height Organizations Sprinkler Identification Number (SIN) us Metric Z ' (15mm) " NPT (RI/2) 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 17 3 2" (20mm)," NPT (R 8.0 115 2.3" (58mm) 1,2,3,8 R3612 '; fi' (11 mm) y" NPT (RI/2) 4.2 60 2.2" (56mm) 1,2,8 R3613 ae" (10mm) yZ' NPT (RY2) 2.8 40 2. (56mm) 1,2,8 R3611 10mm R e 4.2 60 56mm 4,7 R3614 " Refer to escutcheon data table for approvals and dimensions. 2 a. -iJ2 :u 0a.h 1 (r) RUER rO fl A f2 fSCUTCNfON AM TA" fCR ARRRO"" MD OWEN59N5. " n! — 2 5 /8' DMA. [66.7 —j —� ,w AV CErLWG 2 S /,E' DA [- ".7 CUP / _ _ _ _� _ _ _ I x ,/2' REDUCER �_ _ 1 f L J i v�aro WE OF rrmNO TO FACE OF CErL1NC au NSION, aD.rtJS ru[Nr `j" } lJOSGti�_+ (') RVER V rr CSCU,Cr$ON a4rA rASU: FOR APPROVAL5 AAW DNrNSrVNS. 2. 2 1/4' HOLE WA –_. (5).2 —," - I r5 /r6' Do f A9 2mml I x r/2' NP T ACA# SP AfiN B OSS 1CR Brrf� Buss —� i AQII/57Y[Nl r' p��y21 (% TTTT"'.�l l CDL#. a 2 a. -iJ2 :u 0a.h 1 (r) RUER rO fl A f2 fSCUTCNfON AM TA" fCR ARRRO"" MD OWEN59N5. " n! — 2 5 /8' DMA. [66.7 —j —� ,w AV CErLWG 2 S /,E' DA [- ".7 CUP / _ _ _ _� _ _ _ I x ,/2' REDUCER �_ _ 1 f L J i v�aro WE OF rrmNO TO FACE OF CErL1NC au NSION, aD.rtJS ru[Nr `j" } lJOSGti�_+ (') RVER V rr CSCU,Cr$ON a4rA rASU: FOR APPROVAL5 AAW DNrNSrVNS. 2. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1 FR Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model F1 FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1 FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Te Ratin Classification Sprinkler Tem r ature Max. Ambient Temp. Bulb Color °C °F Ordinar Min Recess 3 /," _ Sprinkler Min Recess 1 .1mm (5mm -17mm) Black Plated n r la Black Paint 24mm Off White Yellow I ntermediate 1 reen Hi gh , ue 11 mm Thread -off (') Not available for recessed sprinklers. Escutcheon Data Face of R" Approvals Adjustment „ Dim nsion to Ceillieg or NkXJW � Wall Dimension F1 1,2,4,8 Max Recess z (38.1 mm) Brass F2 1,2,3,4,5,7,8 Min Recess 3 /," (5mm -24mm) Sprinkler Min Recess 1 .1mm (5mm -17mm) No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes "121 Standard Finishes Sprinkler Escutcheon 1y „ Brass F2 1,2,3,4,5,7,8 Max Recess (38.1 mm) Y'a " Sprinkler Min Recess 'y;e" (5mm -17mm) Black Plated Black Plated Black Paint 24mm Off White FP 1,2 Max Recessed 1y "(38.1 mm) Push -on/ 11 mm Thread -off 1,2 Min Min Recessed 1 "(25.4mm) (2 No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes "121 Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated t3l Whi te Holyester Uoated W hite Painted 3i Special A pplication Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult the factory for details. FM Approvals is limited to bronze and brass, chrome or black plated finishes only. FP Push- on/Thread -off escutcheon Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1 FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800)431 -1588 Sales Offices (800)848 -6051 Sales Fax Reliabld (914)668 -3470 Corporate Offices www.reliablesprinkler.com Internet Address 0 Recycled Paper Revision lines indicate updated or new data EG. Prinled in U.S.A. 7/05 P/N9999970027 tqC0 Fire &Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series DS -1 — 5.6 K- factor Dry Type Sprinklers Standard R esponse, Standard Coverage General Description The Tyco® Series DS -1, 5.6 K- factor, Standard Response, Standard Cover- age, Dry Type Sprinklers are decorative 5 mm glass bulb automatic sprinklers designed for the following typical uses: • where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing temperatures (e.g. sprinkler drops from unheated portions of buildings) • where sprinklers and /or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated area of a building) • where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS -1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model /Sprinkler Identification Numbers TY3255 - (Pendent) lQu TY3355 - (Horizontal Sidewall) Technical Data WARNINGS The Series DS -1 Dry Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Approvals UL and C -UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7 -R1 Discharge Coefficient K = 5.6 GPM /psi (80,6 LPM /bar' 2 ) Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated, Brass Plated JANUARY, 2008 Physical Characteristics Inlet ..................... Copper Plug .................... Copper Yoke .............. Stainless Steel Casing .... Galvanized Carbon Steel Insert ................... Bronze Bulb Seat .......... Stainless Steel Bulb ......................Glass Compression Screw ........ Bronze Deflector ................. Bronze Frame ................... Bronze Guide Tube......... Stainless Steel Water Tube ......... Stainless Steel Spring ............. Stainless Steel Sealing Assembly ................ ..........Beryllium Nickel w /Teflon' Escutcheon .......... Carbon Steel 'Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 TFP500 Page 2of8 TFP500 PLUG WITH INLET SPRINKLER FINISH TY3255 Pendent w/ Standard Recessed Escutcheon (Ref. Fig. 3) TY3355 Hor. Sidewal with top of Deflector -to- Ceiling distance of YOKE Recessed Escutcheon (Ref. Fig. 4) 4 to 12 inches (100 to 300 mm) w/ Std. Escutcheon CASING WATER Ref. Fi . 9 INSERT w eep scu c eon (Ref. Fig. 10) TUBE BULB w/o Escutcheon SEAT FRAME (Ref. Fig. 11) Temperature Rating Bulb Color Code Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135'F/57 °C Orange 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1', 2', 3 ", 4 1', 2', 4 155'F/68'C Red 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1',2', 3 ", 4 1', 2', 4 175'F/79'C Yellow 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1',2', 3",4 1', 2', 4 200'F/93 °C Green 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1', 2', 3 ", 4 1', 2', 4 286'F/141'C Blue N/A 1, 2, 3, 4 1, 2, 4 1', 2', 3 ", 4 1', 2', 4 360'F/182'C Mauve N/A 1, 2, 3, 4 1, 2, 4 1', 2', 4 1', 2', 4 Notes: 1. Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada (Maximum order length of 48 inches). 3. Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) 4. Approved by the City of New York under MEA 352 -01 -E. Light and Ordinary Hazard Occupancies Only. " Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS -1, STANDARD RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET GASKETED SPRING PLATE SEAL YOKE SPRING CASING WATER TUBE INSERT GUIDE TUBE BULB SEAT FRAME 5 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS -1, STANDARD RESPONSE DRY TYPE SPRINKLERS ASSEMBLY WRENCH RECESS 2 1 WRENCH FLAT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCH FLATS FIGURE 2 W -TYPE 7 SPRINKLER WRENCH TFP500 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) i� -- }----- - - - FACE OF SPRINKLER { FITTING f J ORDER LENGTHS: 3 -1/2' to 48' (88,9 to 1219,2 mm) IN 1/4 "(6,4 mm) 2 -1/4' DIA. INCREMENTS (57,2 mm) FACE OF CEILING 1 -3/8" t 1/8' 2 -7/8" DIA. (34,9 t 3,2 mm) (73,0 mm) FIGURE 3 TY3255 PENDENT w/ STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) �{ -- i_- _--- - - { - -' I FACE OF SPRINKLER I �1 FITTING ORDER LENGTHS: 3 -1/2' to 48' (88,9 to 1219,2 mm) IN 1/4"(6,4 mm) 3' DIA. INCREMENTS (76,2 mm) FACE OF CEILING � 7F� 1-3/8'± 1/8' 3 -5/8' DIA. (34,9 t 3,2 mm) ( mm) FIGURE 4 TY3255 PENDENT w/ WIDE FLANGE RECESSED ESCUTCHEON Page 3 of 8 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r-- }________ { - -' I- - -, FACE OF SPRINKLER FITTING ORDER LENGTHS: 2-1/2" to 48" 1 -3/4' DIA. (63,5 to 1219,2 mm) (44,5 mm) IN 1/4" INCREMENTS FACE OF CEILING — tc- 2 -3/16' t 1/8" 3' DIA. (55,6 t 3,2 mm) (76,2 mm) FIGURE 5 TY3255 PENDENT w/ STANDARD ESCUTCHEON Page 4 of 8 ORDER LENGTHS: 2 -1/2" to 48" (63,5 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 4" t 1/8" (101,6 t 3,2 mm) FACE OF FACE OF 1 -3/4" DIA. SPRINKLER MOUNTING (44,5 mm) _L FITTING SURFACE 3" DIA. (76,2 mm) � 3.5° SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3355 HORIZONTAL SIDEWALL W/ STANDARD ESCUTCHEON TFP500 Operation When the Series DS -1 is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref. Figure 1) in the Inlet of the Sprinkler. The glass Bulb con- tains a fluid that expands when ex- posed to heat. When the rated tem- perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex- pand and push the Water Tube as well as the Guide Tube outward. This ac- tion simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprin- kler to activate and flow water. Design Criteria The Tyco® Series DS -1 Sprinklers are intended for use in fire sprinkler sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The 1 inch NPT Series DS -1 Sprin- klers are to be installed in the 1 inch NPT outlet or run of malleable or duc- tile iron threaded tee fittings that meet the dimensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the dimension- al requirements of ANSI 816.4 (Class 125). The Series DS -1 Sprinklers may also be installed in the 1 inch NPT out- let of a Grinnell Figure 730 Mechani- cal Tee; however, the use of the Figure 730 for this arrangement is limited to wet pipe systems. Typically, the end sprinkler fitting on a branch line is plugged as shown in Figures 3 through 11. The DS -1 Sprin- klers cannot be installed into an elbow fitting. For wet pipe systems, the sprinkler drop may be installed as shown in Fig- ure 12. The configuration in Figure 12 may only be used where the sprinkler fitting and water filled pipe above the sprinkler fitting is not subject to freez- ing and where the length of the DS -1 Sprinkler has the minimum exposure length per Figure 14. For wet pipe systems, the DS -1 Sprin- klers may also be installed in the fol- lowing Tyco® CPVC fittings: (P /N 80145) 1" x 1" NPT Female Adapter or (P /N 80249) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee. For dry pipe systems, only use the side outlet of maximum 2 -1/2 inch size TFP500 reducing tee's when locating the DS- 1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete drainage of water from above the DS -1 Sprinklers and the branch line. NOTE Do not install the Series DS -1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or bind- ing of the inlet Plug; or, insufficient engagement of the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protect- ing areas subject to freezing tempera- tures (e.g., sprinkler drops into freez- ers), consideration must be given to the appropriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduc- tion. When the temperature surround- ing the wet pipe sprinkler system is maintained at a minimum temperature of 40 °F /4 °C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 40 °F /4 °C — Ref. Figure 14): • 12 inches (300 mm) when the tem- perature within the protected area is - 20 °F / -29 °C • 18 inches (450 mm) when the tem- perature within the protected area is - 40 °F / -40 °C • 24 inches (600 mm) when the tem- perature within the protected area is - 60 °F / -51 °C For protected area temperatures be- tween those given above, the minimum recommended length from the face of the fitting to the outside of the protect- ed area may be determined by interpo- lating between the indicated values. The 2007 edition of NFPA 13, Sec- tion 8.4.10.2 requires that dry sprin- klers connected to wet pipe sprinkler systems protecting insulated freezer structures have the clearance space around the sprinkler barrel be sealed. The use of the Model DSB -2 Dry Sprinkler Boot described in Technical Data Sheet TFP591, and illustrated in Figures 15 and 16, will meet the intent of NFPA 13. TO WET SIDE SYSTEM OUTLET PLUGGED HEATED AREA ffK 1 INCH DSB -2 NPTTEE INTENDED (SEE DESIGN FOR FREEZER CRITERIA STRUCTURES SECTION) T 7 FIGURE 12, SPRINKLER FITTING IN HEATED AREA Page 5 of 8 STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB -2 BOOT ADHESIVE 1 -3/4" DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS -1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB -2 SPRINKLER BOOT WITH PENDENT SERIES DS -1 DRY SPRINKLER 1 -3/4" DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB -2 BOOT STRAP TIES (ENDS DS -1 IN SHOWN WITH OPPOSING STANDARD SIDES OF BOOT) ESCUTCHEON FIGURE 16 MODEL DSB -2 SPRINKLER BOOT WITH SIDEWALL SERIES DS -1 DRY SPRINKLER RUN OUTLET PLUGGED 1 INCH NPT TEE TO DRY (SEE DESIGN SYSTEM CRITERIA SECTION) AREA SUBJECT DSB -2 TO INTENDED FOR FREEZER FREEZING ASTRUCTURES FIGURE 13, SPRINKLER FITTING IN UNHEATED AREA Page 5 of 8 STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB -2 BOOT ADHESIVE 1 -3/4" DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS -1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB -2 SPRINKLER BOOT WITH PENDENT SERIES DS -1 DRY SPRINKLER 1 -3/4" DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB -2 BOOT STRAP TIES (ENDS DS -1 IN SHOWN WITH OPPOSING STANDARD SIDES OF BOOT) ESCUTCHEON FIGURE 16 MODEL DSB -2 SPRINKLER BOOT WITH SIDEWALL SERIES DS -1 DRY SPRINKLER Page 6 of 8 Installation The Series DS -1 Dry Type Sprinklers must be installed in accordance with the following instructions: NOTES The Series DS -1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1,6 mm) for the 135 °F 157 °C rating to 118 inch (3,2 mm) for the 360 °F /182 °C rating. A 1 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque may dis- tort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over - tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent position, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a W -Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W -Type 7 is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling /wall has been installed /finished, slide on the outer - piece of the Escutcheon until it comes in contact with the ceiling /wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling), and then rotate the inner piece approximately 114 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Tyco® Series DS -1 Dry Type Sprin- klers must be maintained and ser- viced in accordance with the following instructions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tems must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole is an indication that there may be weep - age past the Inlet seal and that the sprinkler needs to be removed for de- termining the cause of leakage (e.g. an improper installation or an ice plug). The fire protection system control valve must be closed and the system drained before removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprin- kler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist /slippage, or the like, must be replaced. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). TFP5OO The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. The installing contrac- tor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and /or national codes. TFP500 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and /or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties ex- press or implied including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Dry Sprinklers: Contact your local distributor for availability, and please specify the following: 1. Sprinkler. • Model /SIN. • Standard Response, Standard Coverage, Dry Type Sprinkler • Deflector Style. • 5.6 K- factor. • Order Length. Dry Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 11, as applicable. After the mea- surement is taken, round it to the nearest 114 inch increment. • Inlet Connection (1 Inch NPT or ISO 7 -R1) • Temperature Rating. • Sprinkler Finish. • Escutcheon Style and Finish, as applicable. • Part Number from Table B. (Part numbers are for 1 inch NPT stan- dard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W -Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers, Model DSB -2: Specify: Model DSB -2 Dry Sprinkler Boot', P/N 63- 000 -0 -002. ' Includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (quantity of adhesive is sufficient for installing one Boot) Page 7 of 8 Page 8 of 8 P/N 60 - XXX - X - XXX SPRINKLER MODEL /SIN FINISH 96 Pendent w/ Standard TY3255 NATURAL BRASS Escutcheon (1" NPT) (Fig. 5) 93 Pendent w/ Deep TY3255 CHROME PLATED Escutcheon (1" NPT) (Fig. 6) 97 Pendent w/ Std. Recessed TY3255 Escutcheon (1" NPT) (Fig. 3) 92 Pendent w/o Escutcheon TY3255 (1" NPT) (Fig. 7) 94 Sidewall w/ Standard TY3355 NATURAL BRASS Escutcheon (1" NPT) (Fig. 9) 53 Sidewall w/ Deep TY3355 CHROME PLATED Escutcheon (1" NPT) (Fig. 10) 54 Sidewall w/o TY3355 Escutcheon (1" NPT) (Fig. 11) 98 Upright w/o Escutcheon TY3155 (1" NPT) (Fig. 8) ESCUTCHEON FINISH (2) WHITE WHITE CHROME WHITE WHITE (RAL9010)` BRASS PLATED TEMPERATURE RATING (3) 1 NATURAL BRASS 4 WHITE POLYESTER 9 CHROME PLATED 0 CHROME PLATED 3 WHITE (RAL9010)` 2 NATURAL BRASS ESCUTCHEON FINISH (2) WHITE WHITE CHROME WHITE WHITE (RAL9010)` BRASS PLATED TFP500 TEMPERATURE RATING (3) 0 135F/57C 1 155F/68C 2 175F/79C 3 200F/93C 4 286F/141C 5 360F/182C TFP500 NOTES (1). Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. (2). Escutcheon Finish applies to sprinklers provided with escutcheons. (3). 286F/141C and 360/182C temperature ratings apply to non - recessed sprinkler assemblies. Eastern Hemisphere sales only TABLE B PART NUMBER SELECTION SERIES DS -1, STANDARD RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7 -171 Connection, e.g., 1 -60- 961 -1 -180) © 2007 -2008 TYCO FIRE 8, BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 ORDER LENGTH (1) (EXAMPLES) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" NOTES (1). Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. (2). Escutcheon Finish applies to sprinklers provided with escutcheons. (3). 286F/141C and 360/182C temperature ratings apply to non - recessed sprinkler assemblies. Eastern Hemisphere sales only TABLE B PART NUMBER SELECTION SERIES DS -1, STANDARD RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7 -171 Connection, e.g., 1 -60- 961 -1 -180) © 2007 -2008 TYCO FIRE 8, BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 Component of State of California OSHPD Approved C US bhp Seismic Restraints System Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10' lengths Material — Carbon Steel Maximum Temperature — 750 °F Finish — Plain Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions - WeiQhts Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650 °F 750 °F Wt. /100 114 240 215 12 3/8 1/Z 610 11130 540 11010 29 5/8 1810 1610 bi 84 3/4 2710 2420 123 718 3770 3360 169 1 4960 4420 222 1 8000 7140 360 1�h 11630 10370 510 ® OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. - CORONA, CA 92879 - PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800386.5266 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2 ") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2 thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8 ") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8 "). Conforms to Federal Specifications WW -H -171 E, Type 10 and Manufacturers Standardization Society SP -69, Type 10. Maximum Temperature — 650 °F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOW Fig. 200WON. Order By — Figure number and pipe size BmmorlOmm 3V8 2 400 12 1 1 /4 3/8 8mm or 10mm 3% 2 400 13 1 +h 3/8 8mm or 10mm 3 2 400 14 2 3/8 8mm or 10mm 4 3 400 15 C & US LISTED FM 2�h Dimensions • Weights 10mm 551 4 Pipe Rod Size 3 Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 3�'A 2 400 11 3/4 3/8 8mm or 10mm 3 2 400 11 BmmorlOmm 3V8 2 400 12 1 1 /4 3/8 8mm or 10mm 3% 2 400 13 1 +h 3/8 8mm or 10mm 3 2 400 14 2 3/8 8mm or 10mm 4 3 400 15 C & US LISTED FM 2�h 3/8 10mm 551 4 600 27 3 3/8 1Omm 5�fi 4 600 29 3�h 3/8 10mm 7H 5�/4 600 34 4 3/8 10mm 7H 5 1000 35 5 1/2 12mm 9 6% 1250 66 6 1/2 12mm 10 6Y4 1250 73 8 1/2 12mm 13 1 A 8Y4 1250 136 ® OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 68 - Wide Throat Top Beam "C" Clamp w /Locknut Size Range — 3/8" thru 3/4" rod Function — For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals — Conforms to Federal Specification WW -H -171 E, Type 23 and Manufacturers Standardization Society SP -69, Type 19. Finish — Plain Note — Available in Electro- Galvanized finish. Order By — Figure number, rod size and finish Note — Do not over tighten set screw. Dimensions -Weights Rod Max. Rec. Approx. Size Load Lbs. WtJ100 3/8 400 34 1/2 500 50 5/8 600 53 3/4 800 86 K r I. I ® OFFICE/MANUFACTURING FACILITY - 1375 SAMPSON AVE. - CORONA, CA 92879 - PH: 951.737.5599 - FAX: 951.737.0330 CUSTOMER SERVICE - 800.786.5266 www.toko.com Fig. 25 - Surge Restrainer Size Range — One size fits 3/4" thru 2" pipe. Material — Pre - Galvanized Steel Function — Designed to be used in conjunction with TOLCOO Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals — Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish — Pre - Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4" thru 2 ". Patent #5,344,108 t-{ I I <a A • i �:/ C @ US LISTED OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 m www.toko.com 10.03 FireLock® Fittings VICTAULICS IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION FireLock' products comprise a unique system specifically designed for fire protection services. FireLock full -flow elbows and tees are a CAD - developed, hydrodynamic design that has a shorter center -to -end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. Patented ue See Victaulic publication 10.01 for details. DIMENSIONS I•C to Ey CtoE _ o � C II ,orlo to E L- J' o a No. 001 No. 003 C BtoE� T C ode to E -t No. 002 No. 006 A No. 001 No. 003 No. 002 No. 006 Fitting Size 90° Elbow 45° Elbow Straight Tee Cap 32 Actual - Aprx. - Aprx. - Aprx. Thickness Aprx. Nominal Outside C to E Weight C to E Weight C to E Weight "T" Weight Diameter Diameter Inches Each Inches Each Inches Each Inches Each Inches/mm Inches/mm mm Lh 0ke mm I ha Arn - M I he x... 0.88 �. - A 1.660 - - _ _ _ _ U.66 22 I.0 0.5 32 42.4 - - - - - - 21 0.1 1 % 1.900 2.75 1.2 1.75 0.9 2.75 2.0 0.82 0.4 40 48.3 70 0.5 45 4.1 70 0.9 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 1 51 0.8 70 1 1.1 22 0.3 • 65 � �•� 73.0 76 1.4 ­1 57 c.4 1.0 J.UU 76 J.0 1.6 U.66 22 I.0 0.5 76.1 mm 3.000 3.00 3.30 2.25 1 2.4 - - _ _ 76.1 76 1.5 57 1.1 _ _ 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108 mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - _ 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 159 mm 6.250 5.50 12.6 3.50 9.2 3.50 17.9 - _ 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 1 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 1 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 0 REGISTERED TRADEMARK OF VICTAUUC -0 COPYRIGHT 2006 VICTAUUC - PRINTED IN U.S.A. -SKU NWCAS- 67PJUX t539 REV F United Slates • Phone: 1 -800- PICK -VIC (1- 800 - 742 -5842) • Fax: 610 -250 -8817 • e -mail: pickvic@victaulic.com Canada • Phone: 905 -884 -7444 • Fax: 905- 884 -9774 • e -mail: viccanada@victaulic.com Europe • Phone: 32- 9- 381 -1500 • Fax: 32-9-380-4438 • e -mail: viceuro@victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e -mail: viceuro@victaulic.be Central and South America • Phone: 610 - 559 -3300 • Fax: 610 - 559 -3608 • e -mail: vical @victaulic.com Australasia • Phone: 86 -21- 54253300 • Fax: 86-21-54253671 • e -mail: vicap@viclaulic.com XO/Ictaulic 10.03 FLOW DATA Size Actual Nominal Outside Diameter Diameter 90° Elbow Inches/mm Incheslmm No. 001 Frictional Resistance Equivalent Feet/meters of Straight Pipe 45° Elbow No. 003 Araneh Straight Tee No. 002 Y " 1.660 32 42.4 0.5 0.2 1.1 0.5 1 1 /2 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 t The Flow data listed is based upon the pressure drop of Schedule 40 pipe. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A -536, grade 65 -45 -12 Fitting Coating: Orange enamel • Optional: Hot dipped galvanized This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. FireLockO Fittings 10.02 Style 005 FireLock° Rigid Coupling with Vic -Plus® Gasket System PRODUCT DESCRIPTION FireLock' Style 005 rigid coupling has a unique, patented angle -pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. The FireLock couplings provide rigidity for valve connections, fire mains and long straight runs. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle -pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly; speeds and eases installation on pipe grooved to Victaulic specifications. Style 005 FireLock couplings with the Vic -Plus" Gasket System are designed and recommended for use ONLY on fire protection systems. �a.c11c� Vic -Plus Gasket System: Victaulic® now offers a gasket system which requires no field lubrication on wet pipe systems. The Vic - Plus'" System (patented) is dry, clean, and non - toxic. It reduces assembly time substantially and eliminates the mess and chance of over - lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1 -100) for supplemental lubrication requirements. _j ULC UL FM II P (( VdS § LPC and VdS Approved, Exaggerated for clarity Request Victaulic ` see notes on page 2. publication 10.01 for details. DIMENSIONS Rated for wet and dry sprinkler systems at 350 psi (2413 kPa) for 1'l4 - 4" (32 - 100 mm) sizes and 300 psi (2068 kPa) for 4'/4- 8" (108 - 200 mm) sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expansion, contraction or angular deflection. Pipe Size 42,4 2413 3370 1,2 Actual Max. Max. Allow. Nominal Outside Work. End Pipe End Diameter Diameter Press. §' Load' Sep. t Inches/mm Inches/mm PSI/kPa LhaJN In tmm VICTAULIC' IS AN ISO 9001 CERTIFIED COMPANY VicPlus Gasket System Dimensions Inches/mm Bolt/Nut I Aprx. No. - Size WgL Ea. 32 42,4 2413 3370 1,2 2-3/a X 21/4 70 114 148 0,5 1 1.900 350 990 0.05 2 3 /a X 21/2 3.00 4.75 1.88 1.2 40 48,3 2413 4415 1,2 2' 3/ X 21/4 76 121 148 0,5 2 2.375 350 1550 0.07 3 2 - 1a X 21/2 3.50 5.25 1.88 1.6 50 60.3 2413 6900 1,7 3 2 - la X 2'1 89 133 148 03 65 73,0 2413 10110 13 2 - 3 /e X 21/2 102 146 148 0,9 76,1 mm 3.000 350 2475 0.07 2 3 /a X 21/2 4.13 5.75 1.88 1.9 76,1 2413 11010 1,7 105 146 148 0,9 3 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 80 88,9 2413 14985 1,7 3 2 - la X 2'1 118 156 148 1,0 4 4.500 350 5565 0.16 5.75 7.25 2.13 3.1 100 114,3 2413 24770 4,1 3 2 - /e X 2 12 146 184 54 1,4 108,0 mm 4.250 300 4255 0.16 2 - 3 / X 2'12 5.63 7.25 2.13 3.1 108,0 2068 18940 4,1 143 1 184 54 1,4 5 5.563 300 7290 0.16 6.88 9.00 2.13 4.5 125 141,3 2068 32445 4,1 3 2 - 12 X 2 /4 175 229 54 2,0 133,0 mm 5.250 300 6495 0.16 2 - /2 X 2 6.63 9.00 2.13 4.5 133,0 2068 28900 4,1 168 229 54 2,0 1393 mm 5.500 300 7125 0.16 1 2 - /2 X 2 6.88 9.00 2.13 4.8 139,7 2068 31715 4,1 4 175 229 54 2.2 6 6.625 300 10340 0.16 8.00 10.00 2.13 5.0 150 168,3 2068 46020 4,1 2 - /2 X 231 203 254 54 23 159,0 mm 6.250 300 9200 0.16 s 2 /a X 4 /4 7.63 10.00 2.13 5.5 159,0 2068 40955 4,1 194 254 54 2,5 165,1 mm 6.500 300 9955 0.16 2 ' 1x X 2 8.15 10.00 2.13 5.5 165,1 2068 44295 4,1 207 254 54 2,5 8 8.625 300 17525 0.19 10.50 13.13 2.63 11.3 200 219,1 _2068 76000 1 4,8 s 2 - /e X 4 /4 267 334 67 5,1 @ § t Refer to notes on page 2 0 REGISTERED TRADEMARK OF VICTAUUC - 0 COPYRIGHT 2004 VICTAUUC - PRINTED IN U.SA - SKU MWCAS-87MHPN 1538 REV H Victaulic Company of America • Phone:1 -800- PICK -VIC (1- 800 -742 -5842) • Fax: 610- 250 -8817 • e -mail: pickvicavictaulic.com Victaulic Company of Canada • Phone: 905- 884 -7444 • Fax: 905 -884 -9774 • e -mail: viceanadaDvictaulic.com Victaulic Europe • Phone:32 -9- 381 -1500 • Fax: 32 -9 -380 -4438 • e -mail: viceuroOvictaulic.be Victaulic America Latina • Phone: 610 -559 -3300 • Fax: 610 - 559 -3608 • e -mail: vicalOvictaulic.com / . - C t� u I c Victaulic Asia Pacific • Phone: 86- 21- 58855151 • Fax: 86 -21- 58851298 • e -mail: vicap®victaulic.com .� 10.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. Housing Coating: Orange enamel • Optional: Hot dipped galvanized Gasket: • Grade "E" EPDM - Type A Vic -Plus Gasket System A Violet color code . FireLock products have been Listed by Underwriters Laboratories nc. and Approved by Factory Mutual esearch for wet and dry oil free air sprinkler services up to the rated working pressure us- ing the rade Type A Vic- ]us asket System, requiring no field lubrication for most instal tions. lation condi- For dry services, Victaulic continues to recommend the use of rade Type A FlushSeal" asket. Contact Victaulic for details. Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to -40 F -40 C . ased on typical pipe surface conditions, supplemental lubricant is recommended for services installed below 0 F -18 C and for all dry pipe systems or systems to be sub ected to air tests prior to being filled with water Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has voids and /or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services LISTINGS /APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings /Approvals are sub ect to change and /or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated Working Pressure - PSI Rated Working Pressure - PSI Rated Working Pressure - PSI Pipe Size Pipe Size Pipe Size Sch. Inches UL ULC FM Sch. Inches LJ U LC FM Sch. Inches UL I ULC FM 5 1 /4 - 3 175 1 175 1 175 L 1 - 2 VX1 I /A I /A rAT 1111 inn I 1n I, 1 14 - c 1 aw I auU I rH r r 1 '/4 - 4 A A 300 *F3 /A /A 300 DF 1 1 14 - 4 300 300 300 AL -7 1 /4 - 2 300 /A /A 300 300 /A DT 1'/4- 2 300 300 /A ff P/ - 2 300 /A /A 300 300 300 F 1% - 4 175 /A 175 1'/4 - 4 300 /A 300 FM approved for service in 1' /z - 4 pipe. UL Listed for service up to 4 pipe only. UL Listed for service up to 3 only. PIPE SCHEDULE NOTES: 5 refers to Listed /Approved Schedule 5 steel sprinkler pipe 10 refers to Listed /Approved Schedule 10 steel sprinkler pipe 40 refers to Listed /Approved Schedule 40 steel sprinkler pipe LT refers to Listed steel sprinkler pipe manufactured by Allied Tube Conduit DF refers to Listed /Approved Dyna -Flow steel sprinkler pipe manufactured by Allied Tube Conduit DT refers to Listed Dyna Thread steel sprinkler pipe manufactured by Allied Tube Conduit F refers to Listed /Approved ddy Flow steel sprinkler pipe manufactured by ull Moose Tube Co. L refers to Listed ddylite steel sprinkler pipe manufactured by ull Moose Tube Co. T refers to Listed ddythread 40 steel sprinkler pipe manufactured by ull Moose Tube Co. refers to Listed -Flow steel sprinkler pipe manufactured by orthwest ipe Casing Co. FF refers to Listed Fire -Flo steel sprinkler pipe manufactured by oungstown Tube Co. AL -7 refers to Listed steel sprinkler pipe manufactured by DOD Systems, LLC MLT refers to Listed steel sprinkler pipe manufactured by heatland Tube Company MF refers to Listed Mega -Flow steel sprinkler pipe manfactured by heatland Tube Company MT refers to Listed Mega- Thread steel sprinkler pipe manufactured by heatland Tube Company STF refers to Listed Steady Flow steel sprinkler pipe manufactured by AMS Tube Corporation Steady Thread refers to Appproved steel sprinkler pipe manufactured by AMS Tube Corporation TF refers to Tex -Flow steel sprinkler pipe manufactured by Tex -Tube Company LS refers to Listed /Approved steel sprinkler pipe manufactured by heatland Tube Company L refers to Listed L or L steel sprinkler pipe manufactured by Allied Tube Conduit Corp. NOTES orking ressure and nd Load are total, from all internal and external loads, based on standard weight A S steel pipe, standard roll or cut grooved in accordance with Victaulic specifications Contact Victaulic for performance on other pipe, A FO 0 TM F LD T ST O L , the Maximum oint orking ressure maybe increased to 1 times the figures shown. t For field installation only FireLock Style 005 couplings are essentially rigid and do not accommodate expansion /contraction. umber of bolts required equals number of housing segments. Metric thread size bolts are available color coded gold for all coupling sizes upon request. Contact Victaulic for details. Style 005 couplings are VdS and L C Approved to 12 ar 175 psi . A Depressurize and drain the piping system before attempting to install, remove, or ad ust any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 2 Style 005 FireLock' igid Coupling 1 - 4 350 350 350 T 1'/ - 2 300 /A /A STF 1 1 /4 - 4 /A A 300 10, 40 5-8 300 300 300 4 - 6 300 /A 300 Steady 1 1 /4 - 2 /A /A 300 Thd. I, 1 14 - c 1 aw I auU I rH r r 1 '/4 - 4 A A 300 *F3 /A /A 300 DF 1 1 14 - 4 300 300 300 AL -7 1 /4 - 2 300 /A /A 300 300 /A DT 1'/4- 2 300 300 /A ff P/ - 2 300 /A /A 300 300 300 F 1% - 4 175 /A 175 1'/4 - 4 300 /A 300 FM approved for service in 1' /z - 4 pipe. UL Listed for service up to 4 pipe only. UL Listed for service up to 3 only. PIPE SCHEDULE NOTES: 5 refers to Listed /Approved Schedule 5 steel sprinkler pipe 10 refers to Listed /Approved Schedule 10 steel sprinkler pipe 40 refers to Listed /Approved Schedule 40 steel sprinkler pipe LT refers to Listed steel sprinkler pipe manufactured by Allied Tube Conduit DF refers to Listed /Approved Dyna -Flow steel sprinkler pipe manufactured by Allied Tube Conduit DT refers to Listed Dyna Thread steel sprinkler pipe manufactured by Allied Tube Conduit F refers to Listed /Approved ddy Flow steel sprinkler pipe manufactured by ull Moose Tube Co. L refers to Listed ddylite steel sprinkler pipe manufactured by ull Moose Tube Co. T refers to Listed ddythread 40 steel sprinkler pipe manufactured by ull Moose Tube Co. refers to Listed -Flow steel sprinkler pipe manufactured by orthwest ipe Casing Co. FF refers to Listed Fire -Flo steel sprinkler pipe manufactured by oungstown Tube Co. AL -7 refers to Listed steel sprinkler pipe manufactured by DOD Systems, LLC MLT refers to Listed steel sprinkler pipe manufactured by heatland Tube Company MF refers to Listed Mega -Flow steel sprinkler pipe manfactured by heatland Tube Company MT refers to Listed Mega- Thread steel sprinkler pipe manufactured by heatland Tube Company STF refers to Listed Steady Flow steel sprinkler pipe manufactured by AMS Tube Corporation Steady Thread refers to Appproved steel sprinkler pipe manufactured by AMS Tube Corporation TF refers to Tex -Flow steel sprinkler pipe manufactured by Tex -Tube Company LS refers to Listed /Approved steel sprinkler pipe manufactured by heatland Tube Company L refers to Listed L or L steel sprinkler pipe manufactured by Allied Tube Conduit Corp. NOTES orking ressure and nd Load are total, from all internal and external loads, based on standard weight A S steel pipe, standard roll or cut grooved in accordance with Victaulic specifications Contact Victaulic for performance on other pipe, A FO 0 TM F LD T ST O L , the Maximum oint orking ressure maybe increased to 1 times the figures shown. t For field installation only FireLock Style 005 couplings are essentially rigid and do not accommodate expansion /contraction. umber of bolts required equals number of housing segments. Metric thread size bolts are available color coded gold for all coupling sizes upon request. Contact Victaulic for details. Style 005 couplings are VdS and L C Approved to 12 ar 175 psi . A Depressurize and drain the piping system before attempting to install, remove, or ad ust any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 2 Style 005 FireLock' igid Coupling Mechanical -T® STYLES 920 AND 920N Victaulic Mechanical -T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross -type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to achieve a cross connection. Style 920 and Style 920N Mechanical -T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi /3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly - butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. STYLES 920 AND 920N 4 STYLE 920 CROSS PATENTED Standard piping practices dictate that the Mechanical -T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A -536, grade 65- 45 -12, with orange enamel coating. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. • Optional: Hot dipped galvanized JOB OWNER System No.. Location Gasket: (Specify choice *) • Grade "E" EPDM EPDM (Green color code). Temperature range —30 °F to +230 *F / -34 °C to +110 °C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL Classified in accordance with ANSI /NSF 61 for cold +86 °F / +30 *C and hot +180 °F / +82 °C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T" nitrile Nitrile (Orange color code). Temperature range —20 °F to +180 *F / -29 °C to +82 °C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150 *F / +66 °C or for hot dry air over +140 °F / +60 °C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. CONTRACTOR Submitted By ENGINEER Spec Sect Para Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV I J 2 — c iG 11.02_1 IPS CARBON STEEL PIPE • HOLE CUT PRODUCTS Mechanical -r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS M Ivl r f w FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical -T cross assemblies • Pressure rated up to 500 psi /3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1 h "/50 x 15mm through 8 x 4 7200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. 11.02 UL FM ULC Vds �(�{ SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N STYLE 920 CROSS PATENTED 2 x ',: (a) 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 15 3450 38.1 51 64 41 136 70 _ 1.5 3A (a) 920N 500 1.50 1.97 2.53 - 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1 (a) 920N 500 1.50 1.85 2.53 - 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 41 136 70 1.4 _ 1 Y. (a) t 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 Yz (a) t 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 _ 70 79 41 136 83 1.7 1.5 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. ACtaU iie 11.02_2 REV I IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical -r Bolted Branch Outlets STYLES 920 AND 920N 11.02 U FM U Vds �� - SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N DIMENSIONS rGr ^ wu � IVI Ivl FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical -T cross assemblies • Pressure rated up to 500 psi /3450kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x lh "/50 x 15 mm through 8 x 4 7200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. 4 STYLE 920 CROSS PATENTED TABLE CONTINUED ON PG. 5 14.2 6.4 4.8 2.2 5.1 2.3 5.6 2.5 76 3.4 8.4 3.8 8.4 3.8 10.1 4.6 8.7 4.0 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. �ctaUlld 11.02_4 REV I TABLE CONTINUED FROM PAGE 3 139.7 x 1 7 ' t 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 114 _ 84 209 83 3.2 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 _ 84 209 99 4.1 76.1 mm : 920 500 2.75 3.63 4.75 3.13 9.85 4.63 8.8 3450 69.9 92 121 _ 80 250 118 4.0 76.1 mm 920 500 3.50 _ _ 4.63 3.16 9.70 5.31 11.0 --- 3450 88.9 118 80 246 135 5.0 3 920 500 3.50 3.81 5.00 4.63 3.16 9.85 5.38 14.0 88.9 920N 3450 500 88.9 1.75 96.80 4.43 127 118 80 3.79 250 9.15 137 3.25 6.4 6 1 14 (a) x 150 32 (b) 3450 44.5 112 - - 96 232 83 1 (a) t 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 40 (b) 3450 50.8 112 130 130 96 232 83 2.4 2 (a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5D 3450 63.5 111 130 130 96 232 99 2.7 2''A (a) t 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 65 1 3450 69.9 110 130 130 94 267 118 3.8 76.1 mm 920 500 2.75 _ _ 5.21 3.69 10.51 4.63 3450 69.9 132 94 267 118 _ 3 (a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 80 3450 88.9 110 140 130 94 267 135 4.5 4 (a) t 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 100 920N 3450 500 114.3 1.75 97 4.43 146 5.13 137 94 3.63 267 9.40 159 3.25 4.6 9.0 - 159.0 x 11/4 3 2 3450 44.5 113 130 _ 92 239 83 4.1 1 (a) 92ON 500 2.00 4.41 5.13 3.63 9.40 3.25 78 40 3450 50.8 112 130 _ 92 239 83 15 2 (a) 92ON 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 - 50 3450 63.5 111 130 _ 92 239 99 3.6 TABLE CONTINUED ON PG. 5 14.2 6.4 4.8 2.2 5.1 2.3 5.6 2.5 76 3.4 8.4 3.8 8.4 3.8 10.1 4.6 8.7 4.0 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. �ctaUlld 11.02_4 REV I IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS Mechanical -r Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Exaggerated for Clarity 11.02 U FM U VdS �lf� SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS 0! 0 STYLES 920 AND 920N STYLE 920 CROSS - - -- _ -.._ -- --- __ ---- PATENTED Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 90ON and 929 Mechanical -T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C Values Values for flow of water at +60 °F / +16 °C are shown in the table below. 'i 0.840 9.0 2.0 15 21.3 _ 0.6 34 1.050 11.0 4.0 20 26.7 _ 1.2 1 1.315 13.5 5.0 25 33.7 _ 1.5 1'A 1.660 5.5 6.0 32 42.4 1.7 1.8 1'h 1.900 ZO 8.0 40 48.3 2.1 2.4 2 2375 9.0 10.5 50 60.3 2.7 3.2 2'k 2.875 11.0 12.5 65 73.0 3.4 3.8 3 3.500 13.5 15.5 80 88.9 4.1 47 4 4.500 20.0 22.0 100 114.3 6.1 63 Formulas for C Values: AP = Q' Where: C 2 Q = Flow (GPM) AP = Pressure Drop (psi) Q = C, x AP C� = Flow Coefficient www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. �ctaUlid 11.02_6 REV -1