Loading...
HomeMy WebLinkAboutB10-0397 IVOTE: THIS PERMIT MUST BE POSTED ON JOBS/TE AT ALL T/MES .� �owxo�vn� � Town of Vail, Communiry Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970.479.2139, f.970.479.2452, inpsections 970.479.2149 ADD/ALT MF BUILD PERMIT Permit #: B10-0397 Project #: PRJ10-0726 Job Address: 660 LIONSHEAD PL VAIL Status. . : ISSUED Location......: UNIT 307 Applied . . : 10/27/2010 Parcel No....: 210107201021 Issued. .. : 12/13/2010 Expires. ..: 06/11/2011 OWNER ROCKY MOUNTAIN SKI&RANCH C 10/27/2010 Phone: 952-212-8642 28215 BOULDER CIR EXCELSIOR MN 55331 APPLICANT ROCKY MOUNTAIN SKI AND RANCH 10/27/2010 Phone:612-868-6662 28215 BOULDER CIRCLE EXCELSIOR MN 55331-8325 License:502-L CONTRACTOR ROCKY MOUNTAIN SKI AND RANCH 10/27l2010 Phone:952-212-8642 28215 BOULDER CIRCLE EXCELSIOR MN 55331-8325 License:502-L Description: INTERIOR REMODEL:kitchen,wall in loft, new electrical Occupancy: Valuation: $99,000.00 Type Construction: Total Sq Ft Added: 0 ...,.....«.....�........,..,,,,......x..,.....,,....,...�........����...,....,��,,...�.. FEE SUMMARY ......,,.,,...�.,�,,..,,.�,,.�..�.....�....,.�.......��„�.....,.,.�.................. Building Permit Fee------> $986.75 Will Cal Fee---------------------> $4.00 Total Calculated Fees-------------> $3,412.14 Plan Check--------------------> $641.39 Use Tax Fee---------------------> $1,780.00 Additional Fees-----------------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES-------------> $3,412.14 Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00 Payments------------------------------> $3,412.14 Total Calculated Fees--------> $3,412.14 BALANCE DUE-----------------------> $0.00 ..,>..................................,...,,...,,...........,,..�,,.........:.........,..x....,....�.«..,,..x,...........�.....�,..�,,,.....«,�.,,..,,.,,............,...........,,........... DECLARATIONS I hereby acknowledge that i have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the informatior as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM _.._ 8:00AM-4:00PM....- " ,,. .�_.� _ :.,:. ___ "� r � ` �� � . . � � � Signature of Owner or Contractor Date ��Z���� ��► �r�� Print Name b Id_a It_con structio n_perm it_041908 a.w.•rww+ •�x��.4�.•.+.ri.w��xxx��xx.w...+.�x��.��xxxxxxr+�ww�...���x��x��x�x�xxxe+wwwwwwr�rt+rxxww�xwx++��wwe:�.x������rrx�x�x�+�eewe�+wewww+wr..w������xxx���:��w���+r������xxx++: APPROVALS Permit#: B10-0397 as of 12-13-2010 Status: ISSUED ...,...�..........................................ri ri.........,..,..,.........,,...,......,.....,.,..........,,.,,,...,�,.,...,,,..,......,,...,........,,,,....,,,,..........,.,,,..,... Item: 05100 BUILDING DEPARTMENT 11/22/2010 Martin Action: DN Architectural Comments: Sheet A1.1 1. Provide stair details on plans 2. Stair and landing details and preliminary shop drawings conflict. Stair and landing width do not comply with section 1009.1 IBC 3. Provide details of proposed walls 4. Clarify if safety glazing is required adjacent to proposed stairs. Reference section 2406.4 IBC 5. New closets define rooms as bedrooms. Clarify windows are in compliance with egress requirements. Reference section 1029 IBC Structural Comments: Sheet A1.1 and stir detail 1. Provide structural plans sealed by a registrant showing compliance with sections 1607, 1607.7.1 and Table 1607.1 Plumbing Comments: Provide plans for proposed plumbing Mechanical Comments: Provide plans for proposed mechanical Electrical Comments: Provide plans for proposed electrical 12/11/2010 Martin Action: AP Item: 05110 ELECTRICAL REVIEW 11/22/2010 Martin Action: DN Provide plans 12/11/2010 Martin Action: AP Item: 05120 MECHANICAL REVIEW 11/22/2010 Martin Action: DN Provide plans 12/11/2010 Martin Action: AP Item: 05130 PLUMBING REVIEW 11/22/2010 Martin Action: DN Provide plans 12/11/2010 Martin Action: AP Item: 05400 PLANNING DEPARTMENT 11/22/2010 warren Action: AP Any exterior changes will need to have design review approval. 12/03/2010 Warren Action: AP No comments on the revisions. No exterior changes are approved in conjunction with this permit. No inispections are needed. Item: 05600 FIRE DEPARTMENT 11/01/2010 McGee Action: DN Insufficient information for review. No location shown. 12/09/2010 mcgee Action: COND Submit fire b I d_a It_co n st ru ct i o n_pe rm it_041908 sprinkler and fire alarm revisions. .............�..,,..»........,,,...»....,.,.,....,,,........,,.....,..,...........,.....�,.....�,,,,.......�...........,...........��........,.....,..........,,......,....,......... See the Conditions section of this Document for any that may apply. b Id_a It_con structio n_perm it_041908 x������.x...ww..w������xx�w�....w.���x�x+�x++x....w.�������x�wwxw.....���������w���x�wi�.+wwww��.��ax����w+......w���w��������xw�w�xxx..wwe:a.w��wrw�rwwwwrw��r��������+�����r�rw���� CONDITIONS OF APPROVAL Permit#: 610-0397 as of 12-13-2010 Status: ISSUED ...........................�.»..........x,�,................,.......,..,...........,�...,.....,,..,,.............,,....,...z.,.,.,,,......,,.,�..,�...........,...........,..,,.,,.... Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 bld_a It_co nstruction_pe rm it_041908 +�***************************+++**********************************++*************+********** TOWN OF VAIL, COLORADO Statement **************************+**************************************++************************* Statement Number: R100001991 Amount: $3,412.14 12/13/201009:59 AM Payment Method:Credit Crd Init: RFD Notation: auth #047789 ----------------------------------------------------------------------------- Permit No: B10-0397 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2101-072-0102-1 Site Address: 660 LIONSHEAD PL VAIL Location: UNIT 307 Total Fees: $3,412.14 This Payment: $3,412.14 Total ALL Pmts: $3,412.14 Balance: $0.00 ***+*++*************+*****�***************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 986.75 PF 00100003112300 PLAN CHECK FEES 641.39 UT 11000003106000 USE TAX 4% 1, 780.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- �, ...-. _ ... . � .. _ _ � _ . ._ ,. ._ ._ , ; ; - ; ,::� "�,-° "', r� � f -, � < �,, �, s � � � _ � , Department of Cornmu"ntty.;Development-�: °;� =t ���'�"�', � >, '� ;, -�x -��, :75 South Frontage ftoacl � _ �, � , • ' 3��� '�,< < Y'�� 4� � ` Va�l, �Q.lorac�v 8��i.��;� �� t' i � i Y 1 .,� . ..�..;. .-���� �'�' ` � Q r ' -s '`� _ � '�"�Tei *=.9�0=4�9 ��f'2-��r ._'� = � -;> �r.. � �4 Faic':�97Q �����`.� � , � .; � , ��. � . '� ' s ��111eb� vwv��,va�l�o�c�� -; , . „, ' ,�k �' ' *4 � F � .?'# s e�F�y -a �:n d .r t � y�t. ,� +Yr"y,$',,.�-'g�v � �l y t, � Developmenf,.��rtevY��o�`�tn�to��;t �. �;�3f`��",jlt7y�i l s:� 1�;� �- '"ap"t �r ,a+.i�..�.' �r. i:7.s r �.. r.�.'r -. a � : y '�r y, -;� �``-r,�}� �--.Y� f'� �:�si ���< i J��.i� ,._�. _ __ _.._�....as�' '�' :r��7�t ���`� .r�"—,�}?�-:x' , ''a ....ti.�>a _ fi`�` �-.:z"'`a ° _�=,4 TRANSMITTAL FORM Revision Submittals: 1. "Field SeY'of approved plans MUST accompany revisions. 2. No further inspections will be performed untii the revisions are approved&the permit is re-issued. 3. Fees for reviewing revisions are$55.00 per hour(2 hour minimum), and are due upon issuance. ;Permit#(s)information applies to: Attention: ( Revisions j i , O Response to Correction Letter � ' �� �s�� � �����'� attached copy of correction letter ! � ( ) Deferred Submittal � � �.�AR_� F�1 R6 ( )other j I �.�...�.y...�._., ...._..._. i �Project Street Address: j �� �R �,L � �� 7 `m Description/List of Changes: i �_ _/. 6��..��/ � ,/� i(Number) (Street) (Suite#) � /'� � • � /`�/. .� � i s � i Building/Complex Name: �_T�.]REE SETS j � � � 1 Con�act Information: �.�.� ? ; � 1 'Company: � � Company Address: � j � j 4 ;City: State: Zip: � , � � j Contact Name: � � ! � ��Contact Phone: � �E-Mail � � i i � � ' i..v.,..�..,_..,o._.. � �Revised ADDITIONAL Valuations(Labor&Materials) � j i(DO NOT include original valuation) 3 � ; � ; 3y � ���-- � f ! Building: $ --"" �(use additional sheet if necessary) � � ------_____.......-----------_--—._....------___�-------_________ � � _..._...... --- ;Plumbing: $ , i f Date Received: �Electrical: $ � ! f � ;,; �- � ; j Mechanical: $ � � �� � �j� u � � , � I� i Total: $ ' �' ��-L C9 � f_�,0 I ' � � ���� �OW1� �F VAIL ni r.,.._in ,. ; ` _ � � � t � . : _ " : ����-�� �> ����, �r � _ � '����., �_ �.� ;;�x��� � Department of Community Developmenfi' � �°� .;����� g' � �� ��• �,��"� � �, � 75 South Frontage Road a" '�;��. - � "kxs. �' � -,�,�� _ # �. `;:.,���� � Vail, Colorac�o 81657�� �,� �`t�: �, ,� ��` � �-��:��"� � , �µ° Tel�` 97Q=479 21��� �� '�� �4�, r A n , � A��� r =� - Fax`: 97Q�79 24���; � ��}��. ,�� �t• :,,� �u�.R� � +yr ��'`�`i ...y��f4 } �&�m� �`rn'i"'�'�'at.ae r �"�FN,a ' s � - __ � -, i, � � . k _ ' �-� W�b. www vailgov-ciirr��. �,��`������e�_,��° ""�_ -� _ Deve'�oprnent�e`v�evv Coo�d�n�tu�� .. � ���#uF�� ��� ;� � ��"' _�� F�; ; �r � � �A _�� ' _ . .. . .,.. ��,�4 ,s.' a,,. . � a � � r ��€ � .._._t,.�a��'.c���;.�'«w..���as'a�9 BUILDING PERMIT APPLICATION Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. ;Project Street Address: � ���� �� � � Office Use: E",I, G� _ . �L �/ D /I�S �/9�9 �� — 3✓�7 Project#: ���T�fl� � 7� �D +(Number) (Street) (Suite#) DRB#: Building/Complex Name:�� ,������ / ' Building Permit#: —� q� .. �..�.��.y,�.��.,� ,,�»�:m..�.,.���,� ,�,,.��,�� Contractor Information: ��tl��V� - ��„��'��� Lot#: Block# Subdivision: i Company: ;��:(,� / �7��i�5' ..S°,E ' �`�e�_ ��Company Address: � V"p�/S z�/�j� ��— : � „ � �� ^ ; Detailed Description of Work:_� �� .(�_ !c�ty: �.�GG�1�.3',Dr state:�/1 z�p: S'"S�3 3/ � �_ C2�'_�r���i� Contact Name: �,Q� �P ��/.S�p� � ; _��—�� ` � 6 � �- ��6� ; ' ;Contact Phone: [n /� -� � � E-Mail ' �(use additional sheet if necessary) _l�i�l��C�,,� �'l /� � /�l/ • �� ; �r����.��,M�.�,�� r � ._.�o,��.N_.,�..,�....�..._��..,,..� �_,.�a�.���, ;` Work Class: ,, � ; Town of Vail Contractor Registration No.: 5 Da�— � / ; � New( ) Addition ( ) Remodel(✓) Repair( ) Other( ) ? �V �.._�.,�.,�.�.,�...._.�...-���� : =/\ �Work Type ,�....�.�. -.�.�..�,a .�._..,��.�.,.�.._.., ;Contractor Signature(required) a � ; s Interior(�Exterior( ) Both ( ) ; , ,�.,�.._.�..�,��.�.. .�,....,.�.._...�..��w_,...�,:...� ,m..�.�.�,....�,�,_ : _ .:�� _.�_v,r,,:�. �...,e,�,,.,�.,���.._.�..,�,_��...�,,_.�.�„�,.,..�r, `Property Information f Type of Building: � Mv��� ��.��� !Parcel#: O�/i� / D 7 0� 6 / O� / � � Single-Family( ) Duplex( ) Multi-Family( ) �(For parcel#,contact Eagle County Assessors O�ce at 970-328-8640 or - i visit www.eaglecounty.us/patie) � COmmercial O Other O � Does a Fire A�� �� �Tenant Name: / !� ra � J� � r ��,�,...� .�._�..�n,�,-�,�,,,�.�� ; ...,.,� � � larm Exist? Yes� No( ���� � :Owner Name: ,S�t� ���,�_� �Monitored Alarm? Yes ( �j No( ) � ` : Does a Sprinkler System Exist? Yes O No(�'� ' �x.,�._.�,w.�.�. .�,..�,,,., ....�...�. ,_,..,��� ,�...:.r,.,� ..�.,��.� — ..,.�...�..�.,�.�.,, ,� `Valuations Labor&Material #&Type of Existmg Fireplaces: Gas Appliances ��� ����. � ( )) ��w._.�,.u__�,�-�..,�. _____ _ � � �� �Gas Log � WoodlPellet Wood Buming � `Building: $ �v, �� ' � ' p� '#&Type of Proposed Fireplaces: Gas Appliances ' �Plumbing: $ (j0� ;` Gas Log Wood/Pellet Wood Burning � _ _.__ s _ �Electrical: $ 3.S_ _ _ . __. _. _ _. ;Mechanical: � � ��� �Date Received: D � � � � � � , £TotaL• $��"Z��f� ; OGT 2 s __. __ _ , . ��110 _ _ . 3� la,�y _ � .���N �F !�� �� ---�. _, _�____�= c:\cdev�fonns\permits\bm _ ' g�ermit ]00109 � Ol-Oct-09 � � �.' V IL F\%j\� e — � L8� a � �,� ,1. , � '' � �gR�—� ��c�� � '�QENCY3£��- Vail FICE DepaYtITIG'Ilt Asbestos Testing &Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regu- lations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testinq required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two-Family Dwellings: 30 square feet All Others: 160 square feet Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified and Vail-registered abate- ment contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the Town of Vail before the building permit will be issued Project Checklist My project falls into the category checked below: � Will not disturb more than the threshold limits identified above. � Tested negative, or at 1% or below (2 copies of test results included) Tested positive at more than 1%, requires abatement (2 copies of test results included) �o��E Tips& Facts: • Even recent construction projects may include asbestos-containing materials, so b�ildings of a�age require testing. • The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: State of Colorado Contact: David Rhoades, Fire Inspector Colorado Department of Public Health Vail Fire Department and Environment 75 S Frontage Rd Asbestos Compliance Assistance Group drhoades@vailgov.com 303-692-3158 970-477-3454 asbestos@state.co.us www.vailgov com www.cdphe.state co us c:\cdev\formslpertnits\building\comm_building�ermit_100]09 Final Ciearance Air Monitoring, Services Date: October 18, 2010 PrOjeCt: Abatement of Asbestos Containing Material (ACM) Wallboard Texture from select areas of the Living Room, Dining Room, Kitchen and Entry Loft at the Lions Square Lodge #307 in Vail, Colorado. Contractor: Cemark, Eagle, Colorado Air Monitoring Description• Phase Con provided final clearance air monitoring services at the project site listed above on October 18, 2010. Air samples were situated inside the enclosure so as to be representaCive of the entire work space. Air sampies were obtained utilized aggressive sampling methods to aid in ensuring that any fibrous material left in the enclosure would be entrained in the air during the sampling period. Abatement Description• Abatement of ACM wallboard texture from select areas of the living room, dining room, kitchen and entry loft. ACM texture may stili be present in other areas of the unit which were outside of the scope of work. Comments and Recommendations• PCM analysis of the final clearance air samples revealed airborne ffber levels inside the containment area(s) to be tess than the Colorado State Maximum Allowable Asbestos Leve! (MAAL) and the EPA ciearance levei of 0.010 fibers per cubic centimeter of alr; therefore, the area(s) may be re-occupied under non-abatement conditions. J,,. , U,� � - i;; ;� �'� � �I U I� ,� D as A. Close 11�,� OCl' 2 � 2010 olorado State Air Monitoring Specialist #2930 �u��; " TOWN OF VAIL �i: -�� � �� N ENVtRpNMENTAI CONSULTANTS �,eAtl�►� �as�..... PCM LABORATORY ANALYSIS OSNA Reference Method-NIOSH 7400 Client: Cemark, Inc. Sampiing Date: 10/18/10 Eagie, Colorado Technician/Analyst: D. Ciose Project: Lions Square Lodge, #307 CDPHE Technician ID: 2930 Vail, Colorado Abatement Contractor: Cemark, Inc., Eagle, Colorado Description of Work: Abatement (removal) of ACM Wallboard Texture from Select areas of the Living Room, Dining Room, Kitchen and Entry Loft. SAMPLE SAMPLE DESCR�pTIpN AiR VOLUME fibers/fieids ID f cc 01 Final Clearance Sample - Upper Level 595 L b.0/100 02 Final Clearance Sample - Living Room 595 L <0.005 f cc 5.0/100 03 Final Clearance Sam le - Livin Room <�•OOS F CC p 9 S95 L 5.0/100 04 Finai Cfearance Sam le - Kitchen <0.005 F CC P 595 L 5.0/100 OS Final Clearance Sample - Dining Room 595 L �0.005 F CC 5.0/100 06 <0.005 F CC Blank ----- NONE �� DETECTED Blank ----- NONE DETECTED * Colorado State Clearance Level is 0.010 f/cc of air � � � ,- r - ..--� ,-� 1�,.,f TechnicianJAnalyst: �`�..--�' �l � � � 1 ''� Gra�d Junction. CO 815^v' Qffiice: 970-26G-3341 FhX: 970-241-6584 r ;' .��►��o� `I� • ♦���► `i •�'���♦ .�i ii • 'ti �. ,_\. ' e��O1��0�1p�i�ii. ��+�������/i�i�i. i�1�♦/���{�j�i�i. � �t���������{�i„ ��1����������� �t� ������Q�j• `ti ����������� �i �i�o°}°a vio�`�o���i �itip;eq : .� r I � \\ 1��� . i � 1������ ' ;�i111 �►i 1 i. / ���/�1� i n ��4 �♦ ���•. 1� ��1 •. . ♦Y�p i �` � ; •�..-,� / 41 1 �1 ► /{ r i 1 � ••;. i 1 i0o��� . rt NIi� �o�• .�1�0��l�. •�tl1f il�fiin:\�t�11N1������i;. �\�1 �111� �r��� � l����i i % �11 �i i n i 1l�1 �i� i i i.� �1�1�/ i � � �� �0�10�or+;•, ,1CN1�6p'.•, ; 11�i� '.•=��,'�'r�% `;���!i�',i�'''r i`�`�\�i'�ir,;�'�S r;,i^`�,��,��,,,�,,,,,,...!�����ii",i,/,,.; ���,N�,,,,;��,,f,;h�i��,,,�, � „ i�t+ ►�o., �.1 f o q�hiN,f.e� �'`, !��.��1,�,,:-i� �,�fr��i���;�,y \ .:.i5ini�I�%'„��!\i������i��i����;iS�r;�% �j;��1�I��ii��li��ir/j �Z���1����i���/p�i��/' J���\�11��iii�j�jl�ji�;.\��\�!`�+0�%���a��r�in,�:���1,1��1#1���joii�l��i�.�\�l���l�t+":+°. �rZa,-f, i�i i�\.���i��i.,.��i 1���. ui��� i� \ ,J��i�i� i \ � i iirri 1,�, fi\ i �� \ ♦ � �� �.ii �.i.i�I � ,\ .,��1,,fi!/ � \. . ���4,.ii���n��\\ . � ,�'�i��� 1\�:�,. ������� yi/I��\`�.;��,i�„��i;���'i�% �\��.r���i1'i�i'i��'��:iij �l��Nii/1���1�r'�.�/j1\\\1��iiii�ll��i�.�/J��\\���Z e�j+ �.s���if������\���r,J�,/i�ifi����1�-' ,�..�����i!l,1��1�` ;,:'%i��i�.:.���1\�', �.I;'�i`�i. �`��\.,;�I� �/�`� `,`� ,'�,,i,,-i��� ,,\� ,,_, ������_�'a�i�aQ�\tiy ��,�r.,�,'iieH�`\\\���`� ) !`���f;: � f > >� i� �\ �i����� rii��,'Ti���� '?t h�i�i��\��� 'r' /iiiii������ �.:h;�iah.\�o0� ,>%i��✓i�����`�:. � " . �i\GC<f % ✓ d :���Z�' f� % � `` � ._ ' •• . ... ... . .:_;, � pG� �.��II_�II �//�/%�i• �a• �t-ht f i��i���. ' :%= �`�.� .i�`�' _ _ �.;1���\ • 'Z•''-`c:�" =�=:. ' j �=tr:i;?''°' _ -=S ' �� °� �'Zf�i ' �"�'.t�e� ` r���=.-� STATE OF COL �� � z�=::��1 �<«<� � ORADO �� r� �_.. .F � � ,.;::::.;. �z . ,'.�»� ,� '•e:_-__,,.° 'E :.:;;:-�;%. . !' ,p '-=_- �;':�s:. , °'Z'-z_: -- ,��� fs:�o� \ ;� =r-�'-�,< ���;, --;:_-- •'-: I •�����.�ti:��. ASBESTOS ���".° ���f:, .:;. . -- •a 1 . � Si/��i� _ �.i�S� ; � ,,� a::. :.`��'` ; CERTIFI � ��'�'?��� CATION* '` , .ape�:.=-_ I l�" ";`"�j�i�ir'J. 'r'c c�Q V -_^._. '� �+ �, . i��i..o�tc-'c;:". -,��%°�y'. �9=°°���o �'T„��=�`'�e��i ��� w��d�sl- ��\�.S cv�.:i � �IV��/� Colorado Department of Public Health x� �'� � ���.' • , � , �,, . lY�� .,/'��`� ` �se'�„`= . . � �1�/�%� ` and Environment l7�� �' ' .0.1_q t ji� . .. . .. � �=` :�. :==' � : ` `� �' . Air Pollution � '� , �o:e.�\; � =t�, �`� Control Division _ , �:.,�s.,, ;E - - � =_:o -v..,,f , :� / -�- ,�c�( �Y �' . . . ,�;:,.` ��� ��. 1 d .. .. . �J��\,.' (� �a�: `� -.� ���( . .. �� � . _ . . �ii �'if �. �io tt l �/ . . . ' . .: �. �/%��/,ri .� �.o � ��� '', � ��'. ' �,;: � This certifies that •�. -f1 r, = � '•,�'i� od . �a. ,p,� ' } . - . .... . ... . , � ` `��+.`=i a.� � \ pv r//%///l F G` - . . . .. - ���\\�� :�.:::�,.o., - ; . Douglas A. Close ,� �»>> � :� e:�=_:� �.;; o ._ . ;, :,,,;�s.�-.� . ' ?��0'�t t �/1' ��@o v�: ti ... _. °� � ��.r�z- . . .. . -.. ._.. - ' '°�'�- ;. � . . � Certification No: 2930 _=:9-�:� �.�: _ .°��, .o . ��, t -.=-: ��/��j i�,a��� .� 3 k � � � . •..�ie� i p� <rcGE`'' Z z:-::. �, ;\ ; ,�.-.. �,`1.. ,N»>`�� :;;=`���� - `.�as met the.re uirement Quality Control '�''"sfss� ,",.z,;��. , q s of 25.-7-507, C.R:S. and Air „ s--• �� � •:• - - . � `._:f Corrunission Regulation No. 8, Part B, and is hereby certified by the f`�"' .,.''_ -v�. � o�. ===%��=o- sCate of.Colorado in the following�discipline: ;p �,:.�--,?'; :s�.,,F , � .«cc . ,� .::��;.� }�. •�� ,� � \ ' o�:. ` � l S..J.. �,�, iLi jf°: .00 y�+•� ` :�~p � • 1�1� ' ��;�; A�r Monitor�ng Sp.ecialist* ` - _�::�� � � r,;,;�; ;? i=�:_�. y L..�. -, 1 � ' . � / `\�`���Z?-�, 1 _ �t ! em - ' Issued: 12/8/2009` ' � ': , :t"�''�', ,�:_.:.. . . ( 0 0_�_— - sr�f.=•, , i o:=y�i iv . .. � . � '�s i�.�i�i � j '�����-�'�� �: ! •_':'�����• . '`_�.�a;;-;,.;;�� � Expires on: 12/8/2010 ' � - �`=:�=�-�°;, ' p�� . �. �`'��_=��♦ /�/�/>/�:�`%� �;�, ��/� �\,�.: .. \�;;���\ > ••��Z� . � • , � ��`.� .°.`�� � ; ; > . �mo±�:oz`� � f .Y;•`:%of/si. ,. >� �-+....,`. 1��`d .� � .,� =�.J1 � °v Au aized P -- • .°' �� A CD RepresentaUve , _._::__•�o• ::+� w/�j�s/ �'' �':t� =• / � �a� r � �/� // : �.� ��9 /i "=�� •Thfs c�rtiftcate is valfd only wlth 1he possession of a eurrtnt Division-approved t�ai�rirrg eourse '?t ,a,�,,,,��f„.• `�"`� � ,t��)�>. i ��o�o':_� ; catl�Tcation in tht dfsclplint spectfred abov� ,,` ;'��;�s-., `��'=°=�:::=='=��". fr>�: l ::SZ.�r_'` =_>�.i � ' ,. ��'�'��y.� i��� iij�i„ =�t� �i%ie�i/ ' 'I� 1 � �� �i(ry, ..1� .. . . .. .. r i�{ � � ia� ��•` \`\\ ..� �' . .. . f� . � .. / ,: ' l � �\o �� l�°:���r:��`�i�i�� �'„ .�I�i ����i����t��� ��\�� �i�i�.,,��� .\��\� ����i� 1����yi�i�/ �". ���� ���..,.i i � � `aii.• � ti � �i� � 5':� � V�i i � i,� �� �r�i���1'�, \ i�� 'l �3� i � i ii � p�o!w�6��1V���:�'��P��ii 1�`�r��\Vi���"r� '��i���;• \\ /�ii r,5 \ � /�i , �; 1 ��{!�i�� �, \ � /1�/ . � \ � / d1 i��/ , ���c;,.i�ii iif..� . %��•:�1 \\V/i'l�1�1�1J51 Z\V�!:�t jl��Nl����\.�`1� ��!i�'dl�'���f��1�1��c��1 /�r,�(i�i'�%i'�1,�i`�\:1urlj�,,��i����n(�,�..,\\\ /i��������',�:\\\,\��j��i�.,� � ���\4��0 �I��L,�i���i,:;,y4�s �I��%�ii: 1 0°0°0•.�1��1\�\.�j�/l�l�1��111�'1�����jl/��l/�j�11111�l\�\�//,/��I�/i��7111\ �\�/f.��p���l��tly�1'YY`\i�i%'i���ll;�'�������� �/,;S�,jdl����i���l��.�l`V���'''i��'i'�i+''i`�:\�i /j�,;,,����r�n�.,`;�tt 1y���':_•,i ; ,o,,�w11101�\�;• �i�;oi�li�ll�1�\��' ,�rl i�l����t 1\. �N��1 r�N�1\ ., i l i ���11 1\���„�i i 1 � ,/i, � ����� \� \ /,r, �� � � ,�� nri�,..,t Si,��;,�%J''�•. �o �/00�10�. „ri����Nf�t�►� .���i��������111��; ;(����/jl�f�l�l�1�1���•���i��i��j�fNljll,fi' ;d/�l��i�i1�f,��11�\�:•.ii�jli������N�l����:'iN�i�1�0��ilV�tl�l��.��ii�i'/i'���y.,\ ����j�i��;�o`� , P��P�i���o ^ �..��I�i�1�1.�� .�'.�1/�`�.�'�.�� .�..������♦����►. ,�a�y�•�1�l�1'1�.�, .ii�i�/��������1���� '.i1���/�f����1#1��� `:i�iii�0��d�i�0���oro'�:!i�S�i��'��1�!`��,a'sf�a�i���`F►e�� � �"�o:a c. .�f�,.���!i,/i�� •::�!- i�� �:���• i� ' �:�J+��� ��� •����•���+�r �• •��a���������,��'il� •�i�o1���46o04L;�o'l` .::p1'`+/'o4t0��1'� �a�.+.'6'''+•��� � �--� T •�0��♦ i ''_� �_ ��� '/ '{lti:�`��': .-� l, ',y`+S�I�l'��r+l�r:�, `'!._'._"L �c.] ��,.r�'l.s•.��h�i�! � �`�.:�I i+��±r j���i �.F. '.C�t.�i �/�:;�'i.`-ZSIt:..., A I-� �7�'.-�1'Yjj.t ll�= '•�,'- .�:: ., ':�: -ii ..�,�? .`, �:.:..�,ClM1`.� .,-� � � r` � � � � ,_ __:::. � =:_ARCHITECT SERIES ' „�,�;yCU:r��ies _. _ . �ltn!.iat.. � HU`NG - ArchitectSeries�Wood' I� Glazing Performance �—� Total Unit �� _ _r - y. Shaded Areas Meet ENERGY STAR` - - ' � � a° ' �`.. : Performance Griferia in Zones Shown T Type of G1�zing • _ _ - �.iy . S .� � V � -. "> >'' U:S. ,Canada�:� ' - r__:: � Zone ER Zone� � _ � ..._-- �; _5/8 clear IG with;' >-rirn , i �_�.. w L i� 5'v � 4Z t_�ntit :grafles b,etweec�he-�I��S_;:_�.�.�,,._____. =-�- - �p;48 sY:S4 with integral grilles � � 0 49 0 52 55 42 ��!_8�+,�r�ce oax G with al o��yn��,��i�sm Ia��:W -� " �� ..��.,.�-� � ' ,� �---�M �_.-__--- _,- �A3kl_`�;,,��&-� -x�; �S� ; ._ with gnlles between the glass �-'- - -- =�� � _�. ,,.....,__�_ 0.30 0 26 47� 55 _ - i •_--' avrffi�n� f-���`" �.=- ... _ _ 8�1� 6 es '�---• ` — - -- -�:� _�.. ,�.�_.:_ � __�.=�'�, ��=5�_ 5/8 NaturalSun Low E IG with argon with 25 mm lass � �` �` �..� — ._...�..__,., ._....�_�.�.�-.�.-�- � �--=�� ` ill 5s-�-..........z�..-:3 r' -�._._��-;�=-�-,,� 0 5,�.[�_,..�.,., _ .� �' T� twee�s c � (ass ---=---= .�.M-�.�-(-j�� ��'�' 6 `��'.� e -�,,�:...��x.�.���-�-��-.�.�'� �-�� ., �with integral grdles 0.33 0 48 54 �54 Y �B"'�"v'r� e�nse � oWs�:l��;`�:�y"g--�r?n,,,aN���� -]a—` L T.,--.�= - , : with grilfes-between-tl�e-glass ������'�'� ��2�-'=-���=�=5�^� � � �---- �2hihte r��--�"" 0.29 0 19 44 55 � 1 I _=:�C �....,-=��.� _,__ . 8 ' e�=--�--�- �--�'�:�M Y.� �- Q�O���;�__�' 5/8 SunDefenseTM Dual Low E IG w�th argon with 2.5 mm glass 0 26 4.20 45 Y 44~ i��? u�_ �T�slii�h-:'fJlles�-f��}�,51�5s� ,r-- .� 4:2ti Q 8� _ - �.-�.�. _........._ �""-= T� ��>>r�, - � 1� with integral rilles � " ��-� _�"' ���':� � 0.27 0.18 4Q 44 �� 1 5/8 BronzeAdvanced Low-E IG w/argon with 5 mm/3 mm Low-E Q.33 0.25 3d 52 �=���€�_".IeS7�etWe'e�he='}ass=��z _-- �--s�--- 3 � ��J�__ .,..�C�._ 9 ._ -- .,.x -� -{��.�__,._:.23.r,.�Q TS�-�: w�th mtegrel nlles � - ���8`=:;�.�3.Ad�?�(���_,.....,'o3v__�.E���v r an-aa ° 0 35 0 23 30 . _52 .�9�_�-���trim�f,31fi1ri�L�w`..� `��3i�-=.���r'..3 -=- with gnlles-between the glass --�-�- = ="•=' '=""'..._' - _ - ��---_ � - 5 0 21 26 52 �_:-uG�€�nte�iaT��g�.. �-,..�_ -=,���>�� `0.�� Q.� ``_-_ ��='.�-�`._`"�_ ���?� .�� 5/8 Green Advanced Low-E IG w/argon with 5 mm/3 mm Low E 0 33 p 25 41 52 � w�th�nlies��tr . _'1��- �--� 3 - � .- .�._��.�-x- _m=__�3���__.� �. ' . ._.:,_� -__._�___� ,_.-�--.,._-=�7 __.-���_ ! _ �-,�--._ within,eg,algrilles 0.35 0.22 37 52 . � , i ; 5/8 Advanced Low-c HA 1G wrth 2 5 mm glass 0.33 6.29 53 52 ; =V - � _ � ��.��Ylt��lles1�,g,twe��..{ ��s� �__=__-- _ ; withirrtegralgrilles "^=1 _--,--_.._._� 03�� 15�6-=47 -��v; ��%$ i�l��tcil`al��,'���.t��?�h�.��n ql�ss..,..�... ---=��.-�:�� - - - 0 34 0 26 47 52 --- -=--- wrth gnlles betweerrthe glass — � ��♦�'�� � �ti—'�.=�ii��rt�``r =-_.-.�..••_�-�---�...-�,___ 0 35 0 48 54 5� �--- ��JtU��" .� .���-.�- �-:,=x�:.��l x.3t-4:�-=`� 22 5/8 S u n D e f e n s e7""L o w E H A I G w i t h 2 5 m m lass ��"""`" ����s 2 1 �'----�--�---�- _- 9 0 33 0 21 49 52 ��w�-�-9��[es-ta��v�asuS�ie��'la�s = = ;_ . �-`�033=Li'.15?�--9 G�==�" with integral gnlles ~ " - p - M;SxB�uni�e�� "` " 0 34 19 44 52 '- -=c- -=._L3.F�)f.��'-„�fC*l�`arir�h��tir��-�°n`_'�'�'_�--II��I_-,D 2�-4�.�-'-�.,"' _ - 14 .". with grilles between-the-glass 0 29 0 1$ 40 41 � � - —�--r�- ��-�.�.-Y- =wrth irrte rai� r��_�_=-: ._---_ ._..._--� �-�- �:�_�. _..._�,�T �.__.�•--- x- _ �� ____.___ �__..__.. ,__,. _ _ ,�.- �.._.._.__ _ _ " ---------_-_— - ____._.__ w--..�--���=�..��.:�..4v=—=��": - ,.,.-__ 1? (7?Glazing performance values are calculated based on NFRC 100. Climete 2ones �2?The values shown are 6ased on Canada's updated ENERGY STAR�initiative that will go into effact in October 2010. � For center•glass values,see the Product Performance section. _ _ I R-Value=1N-Factor - -" SHGC=Solar Neat Gain Coefficient Nc � �� _� M VLT%=�sibleLightTransmission � D?� o �'� �_: CR=Condensation Resistance �, SC.• _ ��`r��:-�_ r ;�� ;%;�� ER=Canadian Energy Rating See the General Performance section for more detailed information. "� 4 A� : L ��� Rev.09/30/20i0 PeIla2070ArchitecturalDesignManual • Division08-Openings•WindowsandDoors • www,pellaADM.com � � 5-8 i i a Sidney Schultr _ From: Jennifer Sevde [jsevde@pellacolorado.com] Sent: Monday, October 25, 2010 2:52 PM To: sid@gpslarchitects.com Subject: RE: Fenestration Product Rating Attachments: Glazing Performance, Dave Thomas.pdf Hi Sidney, Please see the glazing performance data, attached. I have starred the glass that is currently in the unit, but alf the High Altitude glass options are available if we need to upgrade to meet any requirements. Please let me know if you need anything else. Thank you, Jenny Sevde Direct Sales Pella Windows and Doors, Inc. 4200 Carson Sh-eet Dem-er, CO 80239 303-3j0-5618 office 303-350-5681 fax 303-726-3979 cell isevde cr pellacolorado com From: Sidney Schultz [mailto:sid@gpslarchitects.com] Sent: Monday, October 25, 2010 2:18 PM To: Jennifer Sevde Subject: Fenestration Product Rating Jennifer, I am working with Dave Thomas on his remodel at Lion Square Lodge#307, your order Number 042, Quote Number 2087782. The Town of Vail now requires that we provide them with the U-factors for windows before they will issue a building permit. Can you e-mail me something with this information? Thanks for your help. Sidney Schultz ,� Sidn�ryr Schultz ; . r�-1.47C1.4lG.11.i,� fvar 47Q.d76.1Si2 .�wothmcy Pratt�chul4z LinrJot) Archit�clz, PC 1t�J0 Snuth fra�fica3e ltoad tMrst.5uite t��Vail.Ctl 81 b`sY w�wrr.��slorah�f+���a.c�ra� **ATTENTION** This email is intended to be a privileged and confidential communication. If � '; you have received this email by mistake please delete it and notify the �'I'`- sender. 10/25/2010 Proposal - Detailed �����'�'�, Pella Windows & Doors � 4200 Carson Street Denver, CO 50239 Phone:(303)371-3750 Fax: (303)371-4268 mer lnformation �' � Day Phone: Mobile Phone: �ax Number: E-Mail: Contact Name: Great Plains#: Qave Thomas l.ot# County: Owner Name: Owner Fhone; Sates Rep.Name: Sevde, Jennifer Sales Rep Phone: 303-350-5618 Sales Rep E-Mail: jsevde@pellacolorado.com Sales Rep Fax: 303-350-5681 ----;�. Idress Order I'nformation�; Quote Name: Dave Thomas Order Number: 042 Quote Number: 2pg77g2 Order Type: Non-installed Safes Wall Depth: Payment Terms: Ta�c Code: Cust Delivery Date: None Quo#ed Date: 10/6/2010 Contracted Date: Booked Date: Customer PO#: For more information regarding the finishing, maintenance, service and warranty of al! PeilaO products, visit the Pella�website at www_pella.com Printed on 10/11/209 0 Detailed Proposal Page 1 of 4 Customer: Project Name: Dave Thomas Line# Location: Quote Number. 2087782 '��' � i �� � �.�_�.. ��... . . �. �s, � �..... �..� � . . �'z�! _ �:.,., .�A%4��iL..iL....... ., �i:H:. i, ,�....� u.............. .. ... ... . .. . � � �: � � � � � - Viewed From E�erior Rough Opening: 96-1l4"X 42-1/4" Final Wall Depth:4-7/16" � I i , , ' I � I Custom Product Instructions: i � i , .� ; ' ' ! Special Architect, 3-Wide Double Hung, 95.5 X 41.5,4-7/16" ltem Price Qty Ext�d price $2,383.71 � $2,383.71 �:Nor+-Standard Size Double Hung,Equal Split Frame Size:22 X 41 1!2 General(nformation: Standard, Luxury Edition,Wood,Pine Exterior Color/Finish:Primed Interior Colo�/Finish:Unfinished Interior Glass:Insulated Tempered Low E Advanced High Altitude Nardware Options:Standard Lock, Oil-Rubbed Bronze,Order Sash Lift Screen:No Screen Gril(e: Vertical Mull 1:FactoryMull,Standard(Vertical Factory)(0") 2:NonStandard Size Fixed Double Hung Frame Size:51 1/2 X 41 1/2 General Information_ Standard,Wood, Pine Exterior Color/Finish:Primed Interior Color/Finish:Unfrnished Interior Glass: Insulated Tempered Low E Advanced High Altitude Grille: Vertica{Mull 2:FactoryMuli,Standard(Vertical Factory)(p") 3:NonStandard Size Double Hung,Equal Spfit Frame Size:22 X 41 1/2 General)nformation: Standard,Luxury Edition,Wood, Pine Exterior Color/Finish:Primed Interior Coior/Finish:Unfinished Interior Gfass:Insulated Tempered Low E Advanced Ffigh Altitude Flardware Options:Standard Lock, Oil-Rubbed Bronze,Order Sash Lift Screen:No Screen GriNe: Wrapping Information:4-7/16"Standard 4sided Jamb Extension,Factory Applied(bVA),Perimeter Length=274",Glazing Pressure=205. I NEED THE EXTERIQR WOOD TO REMAIN UNFINISHED FOR STAINING,NOT PRIMED. "'Wood windows and doors with unfinshed pine exferiors not being properly finished upon receipt,not re�inished annually and/or finished prior to installation will not be covered under the Pella warranty.*** Thank You For Your Interest In PeliaO Products PELLA WAR NTY• Pella products aze covered by Pella's limited wan-anties in effect at the tinae of sa1e.AlI applicable product warranties are incorporated"vnto and become a art Please see the warrauties for complete details,taking special note of the two unportant notice sections regarding installatzon of Pella products and proper xnanagement of mo sture within the wall system.Neither Pella Corporation nor PELLA wINDOWS&DOORS,LLC wiLl be bound by any other warranty uuless specifically set out in this contract. However„P,ella Cozporation will not be liable for bza.ach wazianties which create obligations in add"ztion to or obligations which are inconsistent with pella written warranties. Clear opening(egress)informatzon does not take i�nto consideration the addition of a Rolscreen to ensure your Pella prodncts meet locai egress requirements. [or any other accessory]to the product.You shouid consult your Iocal building code Formore information regarding #he finishing, maintenance, service and warranty of aii Pe!!aO products, visit the Pella�website at www.pel(a.com Printed on 10/11/2010 Detailed Proposal Page 2 of 4 Customer: Project Name: Dave Thomas Quote Number: 2087782 Per the manuf'acturer's limited warranty,unfinished mahogany exterior wizidows and doors must be finished upon receipt prior to installing and refinuis&ed annually,thereafier. Variations in wood gtain,color,texture or natural characteristzcs are not covered under the limited warrantv. BRANCH WARRqNTY• � The full text of ihe manufacturers current warranty can be found at<http://www.pelfa.com/products/warranty.asp> LIMITED WARRAN7Y Supplier(PWD)offers the following Limited Warranty: PWD MAKES NO WARRANTIES OF MERCHANTABiLITY, FITNESS FOR A PARTICULAR PtJRPOSE OR ANY OTHER NATURE OR GUARANTEE, EXPRESS�R IMPLIED. UPON REQUEST,PWD WILL PROVIDE THE MANUFACTURER'S WARRANTIES CURRENTLY IN EFFECT RELATED TO THE MATERIAL SUPPLIED. THE MANUFACTURER'S WARRANTIES SHALL HAVE NO EFFECT UNiIL PWD HAS BEEN PAID IN FULL ALL SUMS DUE AND OWING FOR THE PRQDUCT QR MATERIALS SUPPLIED PURSUANT TO THIS CON7RACT. !n no event shall PWD or Pella Corporation be iiable for consequential,indirect or incidental damages or for any amount in excess of the purchase price whether the claim is for breach of warranty or negligence_ IVATURAL PROPERTIES OF WOOD MATERIALS Wood is a natural product and ihat variations in grain and shading will occur and because no two pieces of wood are exactly alike,variations after finishing are to be expected and are not considered defects. Custom Materials Customer recognizes aad acknowledges that the product or materials supplied by PWD are cusiom in nature and there is no ready market or vafue other than for the job for which the materials are manufactured and/or supplisd_ If Cusiomer ai any time fails to pay PWD for the materials supplied,PWD may,at iYs option,suspend all deliveries or terminate the Contract with the Cusiomer.Such suspension or termination DOES NOT excuse payment for those materials and products already manufactured at the fufl contract price or payment for any component parts already purchased and obtained by PWD. Title Title,ownership and the right to possession of the product or materials furnished or to be furnished by PWD shall remain in PWD until PWD is paid in full. PWD shall have a right to possession of the product or materials but is not obligated to repossess the materials in the event of non-payment.PWD's righ#to repossess materials is in addition to,and not a limitation upon or a waiver of PWD's other legal rights including the right to place mechanic's liens against the real property for which materials were suppfied.All risk of loss or damage shall pass to the Customer upon delivery of the materials. In the event PWD elects to repossess any materials for which payment in fuil has not been made,Customer shal!be responsible for any damage to or loss of materials and their component parts. Risk of�Loss Although title and ownership and the right to possession of the maierials or product fumished or delivered to the Customer sitall remain with PWD until ihe materials are full aid for t loss for the product or materials once they are delivered to ihe Custamer shall be the Customer's responsibility.Therefore,the customer must maintain sufficient insurance t e over any�risk of damage,vandalism or any other loss to the product or materials.Any insurance proceeds woufd be paid over to PWD for the full amount owed to PWD in t he event of any loss. Dispute Resoluiion. Direct piscussior,. If a dispute arises out of or relaies to this Agreement,the parties shall endeavor to settle the dispute through direct discussion_ � Mediation. Disputes not resolved by direct discussion shall be submitted to mediation pursuant to the Construction Indusiry Mediation Rules of the American Arbitration Association. 7he parties shall select the mediator within fifteen{15)days of the request for mediation. Engaging in mediation is a condition precedent to any form of binding dispute resolution. This provislon shall�oi act to delay Supplier filing a mechanEc's lien foreclosure action. The cost of any mediation proceeding shall be shared equally by the parties participaUng. TERMS & CONDITIONS: For more information regarding the finishing, maintenance, service and warranty of all PelfaO products, Printed on 10/11/2010 Detailed Proposal � visit the Pella�website at www.pella.com Paae 3 of Customer: � Project Name: Dave Thomas Customer Name (Please print) Pella Sales Rep Name (Please print) CusEomer Signature Pella Safes Rep Signature Date rt I Date Quote Number: 2087782 Nate: These totats DO NOT include tax For more information regarding the finishing, maintenance, service and warranty of all Pefla�products, visi#the Pella�website at www.pella.com Printed on 10/11/2010 Detailed Proposal Page 4 of 4 StairMeister Lo VI/orks 9 Dave Thom4s / Vail pro ject 10-14-2010 Preliminary design thought for framing of the /anding and p/an view design for stQir ..�_...y � ������� w r mi5n StairMeister Lo Works 9 Dave Thomcrs / Vail project 10-14-2010 Preliminary design thought for frQming of the landing and section view design for stoir 01 -05 -2011 Inspection Request Reporting Page 10 4:28 pm Vail, CO - City Of Requested Inspect Date: Thursday, January 06, 2011 Inspection Area: CG Site Address: 660 LIONSHEAD PL VAIL UNIT 307 A /P /D Information Activity: B10 -0397 Type: A -MF Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: CG Owner: ROCKY MOUNTAIN SKI & RANCH COMPANY Phone: 952 -212 -8642 LLC Contractor: ROCKY MOUNTAIN SKI AND RANCH CO LLC Phone: 952 - 212 -8642 Description: INTERIOR REMODEL: kitchen, wall in loft, new electrical Re uested n IG -Final queMOU SKI AND RANCH CO LLC Comm Assigned To: SGREMMER Action: Time Exp: "Vo Requested Time: 08:30 AM Phone: 612 - 868 -6662 -or- 952 -212- 8642, steve cell Entered By: JMONDRAGON K REPT131 Run Id: 12401 i Inspection History /mer Item: 30 BLDG - Framing ** A 12/15/10 Inspector: sgre Action: NR NOT READY FOR INSPECTION Comment: Cancelled inspection 12/20/10 Comment: Inspector: sgremmer Middle landing and stair belowe Action: DN DENIED is 8" max 7 3/4" rise 01/03/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 60 BLDG - Sheetrock Nail ** Approved ** 12/30/10 Inspector: JRM Action: AP APPROVED Comment: 01/03/11 Inspector: sgremmer Action: AP APPROVED , Comment: Item: 90 BLDG -Final REPT131 Run Id: 12401 i