HomeMy WebLinkAbout1 - 210 C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
1 March 13, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/14/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 54 Air Range(%) 4.5-7.5%
Weather/Temperature Snowing,20's Temperature(°F) 50-90
Placement Location: Footing 211 and 212 near southeast corner of job site.
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 211,Southwest corner 6091 32119610 9:50 11:15 4 7.5 55 - 15 Gallons
Info Only 2nd Truck - - - - - 44 - -
Notification of field test results: Cowboy,Jeff with PCL Construction
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32119610 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 37140 58540 55400
Compressive Strength(psi) 2960 4660 4410
Test Date 02/21/08 03/13/08 03/13/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments A��s�owa�d��ewas�emo�edf�omfoot��9be,o�e�o���eteP�a�ed.Se�o�d�N�kwa544de9,ees,T,oYw��hP��was�o��f�ed.�Y���de�swe,ehea�ed�oo�e,,2ode9�eesd����9�����a�24ho�«��e.Field Technician John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
2 March 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/19/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 126 Air Range(%) 4.5-7.5%
Weather/Temperature Clear 30's Temperature(°F) 50-90
Placement Location: Footings BLL.8/33.9
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BLL.8/33.9 092 32119647 8:45 10:25 3 1/2 5.2 61 - 10 Gallons
Notification of field test results: Tom with PCL Construction
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: g2 Lab ID 895
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 44380 55850 55500
Compressive Strength(psi) 3530 4440 4420
Test Date 02/26/08 03/18/08 03/18/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
3 March 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/19/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 126 Air Range(%) 4.5-7.5%
Weather/Temperature Clear 40's Temperature(°F) 50-90
Placement Location: Footings BLL.8/33.9
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footings BLL.8/33.9 0 32119651 10:17 11:10 4 5.3 56 -
Notification of field test results: Tom with PCL Construction
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID 896
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 32780 60710 52380
Compressive Strength(psi) 2610 4830 4170
Test Date 02/26/08 03/18/08 03/18/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
4 March 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/19/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 126 Air Range(%) 4.5-7.5%
Weather/Temperature Clear 30's Temperature(°F) 50-90
Placement Location: Footings BLL.8/33.9
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BLL.8/33.9 Footings 6038 3211 12:12 12:49 4 1/4 6.1 59 8.0
Notification of field test results: Tom with PCL Construction
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 6038 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 47800 58270 62680
Compressive Strength(psi) 3800 4640 4990
Test Date 02/26/08 03/18/08 03/18/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
5 March 20, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/21/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 280 Air Range(%) 4.5-7.5%
Weather/Temperature Partly Cloudy 20-30's Temperature(°F) 50-90
Placement Location: Footers at Gridlines BEEE.8/B57.9,BGGG.9/B62.4, BNN.4/B62.4
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BEEE.8/657.9 6091 32119685 8:50 10:10 31/4 6.0 46 143.2 10
Notification of field test results: Tom with PCL Construction
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 6091 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 47350 52000 54620
Compressive Strength(psi) 3770 4140 4350
Test Date 02/28/08 03/20/08 03/20/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Tom with PCL notified of low temperature Field Technician John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
6 March 20, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/21/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 280 Air Range(%) 4.5-7.5%
Weather/Temperature Partly Cloudy 20-30's Temperature(°F) 50-90
Placement Location: Footers at Gridlines BEEE.8/B57.9,BGGG.9/B62.4, BNN.4/B62.4
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BEEE.8/657.9 0 32119693 10:46 11:35 6 7.2 50 138.2 15
Notification of field test results: Tom with PCL Construction and -
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 36370 51680 55720
Compressive Strength(psi) 2890 4110 4430
Test Date 02/28/08 03/20/08 03/20/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Tom with PCL Construction notified of high slump Field Technician John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
7 March 20, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/21/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 280 Air Range(%) 4.5-7.5%
Weather/Temperature Partly Cloudy 20-30's Temperature(°F) 50-90
Placement Location: Footers at Gridlines BEEE.8/B57.9,BGGG.9/B62.4, BNN.4/B62.4
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BEEE.8/657.9 6038 32119698 11:28 12:25 41/2 5.4 50 142.8 5
Notification of field test results: Tom with PCL Construction and -
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 6038 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 33620 54810 52860
Compressive Strength(psi) 2680 4360 4210
Test Date 02/28/08 03/20/08 03/20/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
8 February 21, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/21/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 280 Air Range(%) 4.5-7.5%
Weather/Temperature Partly Cloudy 20-30's Temperature(°F) 50-90
Placement Location: Footers at Gridlines BEEE.8/B57.9,BGGG.9/B62.4, BNN.4/B62.4
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BEEE.8/657.9 0 32119703 12:30 1:25 7 6.1 46 140.4
Notification of field test results: Tom with PCL Construction and -
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 6038 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 38050 59440 52710
Compressive Strength(psi) 3030 4730 4190
Test Date 02/28/08 03/20/08 03/20/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Slump of 7"reported to Tom with PCL Field Technician John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
9 March 20, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/21/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 280 Air Range(%) 4.5-7.5%
Weather/Temperature Partly Cloudy 20-30's Temperature(°F) 50-90
Placement Location: Footers at Gridlines BEEE.8/B57.9,BGGG.9/B62.4, BNN.4/B62.4
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BNN.4/B62.4 6038 32119709 1:19 2:10 61/4 4.7 45 143.4 10
Notification of field test results: Tom with PCL Construction and -
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 6038 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 41760 54150 56910
Compressive Strength(psi) 3320 4310 4530
Test Date 02/28/08 03/20/08 03/20/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Slump of 6 1/4"reported to Tom with PCL Field Technician John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
10 March 20, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/21/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 280 Air Range(%) 4.5-7.5%
Weather/Temperature Partly Cloudy 20-30's Temperature(°F) 50-90
Placement Location: Footers at Gridlines BEEE.8/B57.9,BGGG.9/B62.4, BNN.4/B62.4
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BNN.4/B62.4 6036 32119715 2:09 3:00 6 5.5 44 140.4
Notification of field test results: Tom with PCL Construction and -
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 6036 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 37390 57720 54380
Compressive Strength(psi) 2980 4590 4330
Test Date 02/28/08 03/20/08 03/20/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Slimp of 6"report to Tom with PCL Field Technician John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
11 March 24, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/25/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 70 Air Range(%) 4.5-7.5%
Weather/Temperature Clear in the 30's Temperature(°F) 50-90
Placement Location: Footings BNNN.4/71
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BNN.4/71 430 32119736 9:49 10:55 31/2 5.2 61 -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 6036 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 44840 59620 61890
Compressive Strength(psi) 3570 4740 4930
Test Date 03/03/08 03/24/08 03/24/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
12 April 23, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/27/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating/#37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 5 1/2 Air Range(%) 4.5-7.5%
Weather/Temperature Clear in the 40's Temperature(°F) 50-90
Placement Location: Plinths BEE.6, BLL8/62.4
Methods Employed: Crane and hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Plinth BLL.8/62.4 3 32119805 12:07 1:20 6 7.3 62 142.2 -
Notification of field test results: Tom with - with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32119805 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 38930 53810 55270 58410
Compressive Strength(psi) 3100 4280 4400 4650
Test Date 03/05/08 03/26/08 03/26/08 04/23/08
Test Age 7 28 28 56
Type of Fracture
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
13 March 28, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/29/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating/#37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 93 Air Range(%) 4.5-7.5%
Weather/Temperature Clear in the 40's Temperature(°F) 50-90
Placement Location: Pump boom#1
Methods Employed: Pumped to point of piacement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Pump boom#1 6037 32119878 1:03 1:59 6 1/2 7.1 66 142.8 -
Notification of field test results: Tom with PCL Construction
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32119878 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 42150 65920 70230
Compressive Strength(psi) 3350 5250 5590
Test Date 03/07/08 03/28/08 03/28/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
14 March 28, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/29/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 34 Air Range(%) 4.5-7.5%
Weather/Temperature Clear Temperature(°F) 50-90
Placement Location: Footings/1058/1055
Methods Employed: Pumped the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footings/1058/1055 0 32119856 8:47 10:15 51/2 5.7 66 - -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32119856 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 30210 59790 61320
Compressive Strength(psi) 2400 4760 4880
Test Date 03/07/08 03/28/08 03/28/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
15 March 28, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 02/29/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 93 Air Range(%) 4.5-7.5%
Weather/Temperature Clear in the 40's Temperature(°F) 50-90
Placement Location: Pump boom#1
Methods Employed: Pumped to point of piacement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Pump boom#1 6045 32119884 2:40 3:45 6 1/4 6.5 70 141.8 -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 49120 82140 84100
Compressive Strength(psi) 3910 6540 6690
Test Date 03/07/08 03/28/08 03/28/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
16- April 1, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/04/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 40 Air Range(%) 6%+/-1.5%
Weather/Temperature Cloudy in the 20's Temperature(°F) 50-90
Placement Location: Footing at BZZ.9/49
Methods Employed: Placed by chute
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing at BZZ.9/49 6037 32119911 10:00 10:30 4 1/2 6.6 50 - 10
Notification of field test results: Tom with PCL and -
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 41480 54800 55150
Compressive Strength(psi) 3300 4360 4390
Test Date 03/11/08 04/01/08 04/01/08
Test Age 7 28 28
Type of Fracture
Additional Comments Reinforcingsteeliorihisandsoulheastelevatorstaircasefoundationwallsobservedandappearedtobeplacedingeneralaccordancewilhiheprojectplansandspecifcations FI@�C�T@C�11lIC1a11 John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
17- April 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/05/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 24 Air Range(%) 4.5-7.5
Weather/Temperature Clear in the 20's Temperature(°F) 50-90
Placement Location: Shear Walls
Methods Employed: Pumped to point of piacement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BGGG2/657.2-shear walls 6004 32119946 11:40 1:00 8 7.5 58 138.0
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32119946 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 48890 67730 70430 77230
Compressive Strength(psi) 3890 5390 5600 6150
Test Date 03/12/08 04/02/08 04/02/08 04/30/08
Test Age 7 28 28 56
Type of Fracture
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
18- May 1, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/06/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 46 Air Range(%) 4.5-7.5%
Weather/Temperature Clear in the teens Temperature(°F) 50-90
Placement Location: Footing
Methods Employed: Tailgated to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BZZ.9/47.5 6004 3219 12:17 1:32 31/2 6.1 55 140.0
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 40080 56100 58630 64460
Compressive Strength(psi) 3190 4460 4670 5130
Test Date 03/13/08 04/03/08 04/03/08 05/01/08
Test Age 7 28 28 56
Type of Fracture
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
19 April 7, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 190 Air Range(%) 4.5-7.5%
Weather/Temperature Clear Temperature(°F) 50-90
Placement Location: Footing
Methods Employed: Point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
70/H.5 0 32120000 8:43 9:37 41/2 7.1 68 139.2 -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120000 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 26300 37870 43910
Compressive Strength(psi) 2090 3010 3490
Test Date 03/17/08 04/07/08 04/07/08
Test Age 7 28 28
Type of Fracture T-5 Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
20 April 7, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 190 Air Range(%) 4.5-7.5
Weather/Temperature Clear in the 40's Temperature(°F) 50-90
Placement Location: Footing
Methods Employed: Pumped to the Point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
70/H.5 0 32120009 10:20 11:10 5 6.2 61 143.2 -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120009 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 33970 47680 50510
Compressive Strength(psi) 2700 3790 4020
Test Date 03/17/08 04/07/08 04/07/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
21 April 7, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 190 Air Range(%) 4.5-7.5
Weather/Temperature Clear in the 40's Temperature(°F) 50-90
Placement Location: Footing
Methods Employed: Pumped to the Point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
70/H.8 6092 732120017 11:31 12:31 81/2 4.5 54 141.8 -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 732120017 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 29700 46350 48040
Compressive Strength(psi) 2360 3690 3820
Test Date 03/17/08 04/07/08 04/07/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
22 April 7, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 190 Air Range(%) 4.5-7.5
Weather/Temperature Clear Temperature(°F) 50-90
Placement Location: Footings
Methods Employed: Pumped to the Point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BNNN.4/52.3 6037 32120026 1:58 3:10 5 5.1 63 141.2 -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120026 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 30910 44370 45630
Compressive Strength(psi) 2460 3530 3630
Test Date 03/17/08 04/07/08 04/07/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
23 April 9, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/12/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 87 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/30's Temperature(°F) 50-90
Placement Location: Footings at MM-57.2, BAAA.2-63.7 and BTT.9-71
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing at MM-57.2 6012 32120065 8:40 10:05 4 6.8 57 140.3
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120065 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 26500 39260 42690
Compressive Strength(psi) 2110 3120 3400
Test Date 03/19/08 04/09/08 04/09/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
24 April 9, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/12/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 87 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/30's Temperature(°F) 50-90
Placement Location: Footings at MM-57.2, BAAA.2-63.7 and BTT.9-71
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing at BTT.9-71 0 32120087 11:04 12:07 4 3/4 5.8 60 141.2 5
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120087 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 26920 39030 44930
Compressive Strength(psi) 2140 3110 3580
Test Date 03/19/08 04/09/08 04/09/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
25 April 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/13/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 110 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Footings at(M-Y)to(B40.3-49)
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Gridlines P-39.5 6037 32120124 7:42 9:04 4 1/2 5.8 55 141.2 5
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120124 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 31130 50310 46180
Compressive Strength(psi) 2480 4000 3670
Test Date 03/20/08 04/10/08 04/10/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
26 April 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/13/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 110 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Footings at(M-Y)to(B40.3-49)
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Gridlines M-41 0 32120133 9:29 10:33 5 6.6 57 139.8 5
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120133 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 29630 42660 40670
Compressive Strength(psi) 2360 3390 3240
Test Date 03/20/08 04/10/08 04/10/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
27 April 11, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/14/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 107 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/30's Temperature(°F) 50-90
Placement Location: Footings 1055, 1058, 1010, 1026
Methods Employed: Pump to point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1055 6093 32120125 11:55 1:10 5 6.1 57 142.2 -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 32040 50060 49340
Compressive Strength(psi) 2550 3980 3930
Test Date 03/21/08 04/11/08 04/11/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
28 April 11, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/14/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 107 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/30's Temperature(°F) 50-90
Placement Location: Footings 1055, 1058, 1010, 1026
Methods Employed: Pumped to placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1058 6093 32120163 11:50 2:00 4 1/2 6.1 51 138.2 -
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 30930 44430 48300
Compressive Strength(psi) 2460 3540 3840
Test Date 03/21/08 04/11/08 04/11/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
29 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 490 Air Range(%) 6%+/-1.5%
Weather/Temperature Sunny/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
West end of footing 6092 32120191 6:38 8:09 3 1/4 6.3 50 139.8
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120191 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 31170 45660 50150 35910
Compressive Strength(psi) 2480 3630 3990 2860
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
30 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating# Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 475 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Base
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Northeast Tower Crane Base-west half 0 32120199 7:58 8:47 4 1/2 6.9 55 138.7
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120199 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 33870 48150 49020 44040
Compressive Strength(psi) 2700 3830 3900 3500
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
31 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 475 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: East Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Northeast corner of footing 321 32120206 8:51 9:50 4 3/4 6.9 53 137.9
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120206 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 35560 49440 51640 44010
Compressive Strength(psi) 2830 3930 4110 3500
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
32 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 475 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Southwest corner of footing 6037 32120211 9:25 10:20 5 1/2 7.0 54 137.5 5
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120211 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 34950 50960 47550 40520
Compressive Strength(psi) 2780 4060 3780 3220
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Tom with PCL Construction was notified of the high slump Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
33 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 475 Air Range(%) 6%+/-1.5%
Weather/Temperature Sunny/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
South end of footing 6093 32120217 10:22 11:19 5 1/4 6.2 54 138.4
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120217 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 28400 49880 50110 39800
Compressive Strength(psi) 2260 3970 3990 3170
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
34 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 500 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Southwest corner of footing 0 32120222 10:57 11:50 5 1/4 7.0 56 137.7
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120222 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 29150 51110 47180 38410
Compressive Strength(psi) 2320 4070 3750 3060
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
35 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 500 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Southeast corner of footing 6038 32120228 11:58 12:21 5 6.8 53 138.2
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120228 Lab ID 988
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 26650 42930 46220 32780
Compressive Strength(psi) 2120 3420 3680 2610
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
36 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 500 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Middle of footing 0 32120235 12:31 1:18 6 6.0 53 138.6
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120235 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 28320 48700 49510 38830
Compressive Strength(psi) 2250 3880 3940 3090
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
37 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 500 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Middle of footing 0 32120242 1:18 2:09 5 1/2 6.7 56 137.8
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120242 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 28180 44770 45620 37510
Compressive Strength(psi) 2240 3560 3630 2980
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
38 April 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/18/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 500 Air Range(%) 6%+/-1.5%
Weather/Temperature Partly Cloudy/20's Temperature(°F) 50-90
Placement Location: Northeast Tower Crane Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Northeast corner of footing 6037 32120247 1:55 2:50 6 1/4 6.9 54 138.1 10
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120247 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 25250 40560 41670 35650
Compressive Strength(psi) 2010 3230 3320 2840
Test Date 03/25/08 04/15/08 04/15/08 03/31/08
Test Age 7 28 28 13
Type of Fracture
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
39 April 16, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/19/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 6 Air Range(%) 6%+/-1.5%
Weather/Temperature Clear/40's Temperature(°F) 50-90
Placement Location: Grade Beams at A3-BZZ.9/BTT.9 and A2-BGGG.2/BAAA.2
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
6091 32120281 2:00 3:25 4 5.5 51 140.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120281 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57 12.57
Maximum Load 23960 27510 45290 40750
Compressive Strength(psi) 1910 2190 3600 3240
Test Date 03/22/08 03/26/08 04/16/08 04/16/08
Test Age 3 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
40 April 17, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/20/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 8 1/2 Air Range(%) 6%+/-1.5%
Weather/Temperature 40 degrees Temperature(°F) 50-90
Placement Location: BQQQ.4/40.5 Grade Beam
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BQQQ.4/40.5 Grade Beam 6093 32120297 11:50 1:00 5 5.5 57 140.5
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120297 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 30010 45960 47320 29270
Compressive Strength(psi) 2390 3660 3770 2330
Test Date 03/27/08 04/17/08 04/17/08 03/24/08
Test Age 7 28 28 4
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
41 April 24, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/27/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 39 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/40's Temperature(°F) 50-90
Placement Location: Frost walls M/70 footing
Methods Employed: Pumped ot the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
M.9/69 6092 32120498 8:51 10:25 61/2 7.5 57 142.4
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120498 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 48040 74410 65390
Compressive Strength(psi) 3820 5920 5200
Test Date 04/03/08 04/24/08 04/24/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
42 April 24, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/27/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 40 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/40's Temperature(°F) 50-90
Placement Location: D/71, D/65.5, H.S171 Footing
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing D/71 0 32120504 10:13 11:30 5 8.5 58 139.4
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 27040 35320 34270 42170
Compressive Strength(psi) 2150 2810 2730 3360
Test Date 04/03/08 04/24/08 04/24/08 05/22/08
Test Age 7 28 28 56
Type of Fracture
Additional Comments Tom was notified of the high air content. Field Technician Justin Heinrick
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
43 April 25, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 03/28/08 Specifications
Concrete Placed By: PCL Construction Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 90 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/40's Temperature(°F) 50-90
Placement Location: Footings at gridlines 41/BQQQ.4, M/63,and H/41
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing M/63 6037 32120541 11:56 1:15 5 6.5 65 140.2
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120541 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 30240 43610 48330
Compressive Strength(psi) 2410 3470 3850
Test Date 04/04/08 04/25/08 04/25/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
CRDUIIIn
ENGINEERING CDNSULTRNTS
CONCRETE PROPERTIES
Project: Ritz Carlton Residences
Job Number: 08-6502 Date: 4/25/2008
Client: RCR Vail LLC
953 South Frontage Road West, Suite 215
Vail, Colorado 81657
Attn: Mr. David Williams Cylinder Set Number: 44
Compressive Strength of Concrete Cylinders
Cast Date: 3/28/2008 Laboratory ID #:
Placement Location: South Shoring wall
Supplier/ Mix ID: Yenter on-site mix, approx .44 w/c ratio
Fresh Concrete Test Data Specifications
Slump (inches) NA (ASTM C 143)
Air Content (%) NA (ASTM C 231)
Temperature (°F) NA (ASTM C 1064)
Unit Weight (pc� NA (ASTM C 138)
Initial Cure Standard Initial Cure
Final Cure ASTM C31 - Laboratory Curing Room
Compressive Strength Test Data (ASTM C39)
Cylinder Set Number 44 A 44 B 44 C 44 D
Diameter(in.) 4.00 4.00 4.00 4.00
Cross Sect. Area (sq. in.) 12.57 12.57 12.57 12.57
Maximum Load (Ibf) 45,480 58,930 60,620
Compressive Strength (psi) 3620 4690 4820
Specified Strength (psi) Not provided
Test Date 04/04/08 04/25/08 04/25/08
Age at Test (Days) 7 28 28 Hold
41 Inverness Drive East 7393 Dahlia Street P.O.Box 464
Englewood,CO 80112 Commerce City,CO,80022 Gypsum,CO 81637
Tel:(303)289 1989 Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Fax:(303)289 6742 Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
45 May 2, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/04/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 10 Air Range(%) 4.5-7.5%
Weather/Temperature 40's Temperature(°F) 50-90
Placement Location: Plinths at(#202),42/H.0 and (#198), MD/B65.4
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
(#202),42/H.0 and (#198), MD/665.4 6091 32120725 12:07 1:15 6 5.5 60 145.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120725 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 51820 66470 70480
Compressive Strength(psi) 4120 5290 5610
Test Date 04/11/08 05/02/08 05/02/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
46 May 2, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/04/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 30 Air Range(%) 4.5-7.5%
Weather/Temperature 40's Temperature(°F) 50-90
Placement Location: Footing#1095-59/O
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing#1095,59/D.O 6037 32120726 12:26 1:45 5 5.5 62 142.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120726 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 38110 53240 52060
Compressive Strength(psi) 3030 4240 4140
Test Date 04/11/08 05/02/08 05/02/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
47 May 6, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/08/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 37 Air Range(%) 6%+/-1.5%
Weather/Temperature 30's Temperature(°F) 50-90
Placement Location: BEE.6/72,4/72, R/72, (1075, 1083,and 1084)&A7/P/72,A6/4/72,A5/4/72
Methods Employed: Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Grade Beams 72/4,72, R/72 6003 32120756 8:52 10:00 6 6.2 55 140.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120756 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 27130 46200 44540
Compressive Strength(psi) 2160 3680 3540
Test Date 04/15/08 05/06/08 05/06/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments We notified Jeff and Tom of the slump. Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
48 May 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 130 Air Range(%) 4.5-7.5
Weather/Temperature Snow/20's Temperature(°F) 50-90
Placement Location: Footing at R/59(1074)
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
R/59 1074 footer 0 32120809 9:00 10:15 5 7.5 55 140.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120809 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 26550 39220 39650
Compressive Strength(psi) 2110 3120 3160
Test Date 04/17/08 05/08/08 05/08/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
49 May 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 130 Air Range(%) 4.5-7.5
Weather/Temperature Snow/20's Temperature(°F) 50-90
Placement Location: Footing at(1074)R/59
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1074 R/59 0 32120816 10:50 11:45 7 5.2 53 144.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120816 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 30700 46280 43040
Compressive Strength(psi) 2440 3680 3430
Test Date 04/17/08 05/08/08 05/08/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments We notified Tom of the 7"slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
50 May 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 130 Air Range(%) 4.5-7.5
Weather/Temperature Snow/20's Temperature(°F) 50-90
Placement Location: Footing at(1074)R/59
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1074 R/59 0 32120823 11:54 12:20 5 6.8 55 144.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120823 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 32040 46380 44970
Compressive Strength(psi) 2550 3690 3580
Test Date 04/17/08 05/08/08 05/08/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
51 May 9, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/11/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 20 Air Range(%) 4.5-7.5
Weather/Temperature Snow/20's Temperature(°F) 50-90
Placement Location: Grade Beam at 1085-1073 P/72 and KK/72
Methods Employed: Hopper/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Grade Beam at 1085-1073 P/72&KK/72 6036 32120849 12:50 1:45 6 5.5 58 140.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120849 Lab ID 49
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 46150 71330 72870 76770
Compressive Strength(psi) 3670 5680 5800 6110
Test Date 04/18/08 05/09/08 05/09/08 06/06/08
Test Age 7 28 28 56
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
52 May 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/12/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 186 Air Range(%) 4.5-7.5
Weather/Temperature Clear/20's Temperature(°F) 50-90
Placement Location: Footings 1074, 1066,and 1056
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footings 1056 0 32120862 8:15 8:45 5 5.7 49 144.6
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120862 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 34580 41840 45330
Compressive Strength(psi) 2750 3330 3610
Test Date 04/19/08 05/10/08 05/10/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
53 May 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/12/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 186 Air Range(%) 4.5-7.5
Weather/Temperature Clear/20's Temperature(°F) 50-90
Placement Location: Footings 1074, 1066,and 1056
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footings 1074 6037 32120856 6:51 8:10 6 6.0 51 144.2
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120856 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 33430 44940 42540
Compressive Strength(psi) 2660 3580 3390
Test Date 04/19/08 05/10/08 05/10/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
54 May 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/12/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 186 Air Range(%) 4.5-7.5
Weather/Temperature Clear/20's Temperature(°F) 50-90
Placement Location: Footings 1074, 1066,and 1056
Methods Employed: Pumped to the point of placement
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footings 1066 0 32120870 9:51 10:52 5 1/2 6.1 52 143.2
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120870 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 37960 48580 52400
Compressive Strength(psi) 3020 3870 4170
Test Date 04/19/08 05/10/08 05/10/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
55 May 12, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/14/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 100 Air Range(%) 4.5-7.5
Weather/Temperature Clear/30's Temperature(°F) 50-90
Placement Location: Footings at KK/647.5 and BRR.5/647.5
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Gridline KK/B47.5 6003 32120925 11:52 1:30 2 3/4 5.0 68 145.2
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120925 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 37920 56840 56900
Compressive Strength(psi) 3020 4520 4530
Test Date 04/21/08 05/12/08 05/12/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments We notified Tom and John of the slump. Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
56 May 12, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/14/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#3732400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 10 Air Range(%) 4.5-7.5
Weather/Temperature Clear/30's Temperature(°F) 50-90
Placement Location: Shear Wall at R/59.2
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Shear Wall at R/59.2 6093 32120938 3:00 3:45 6 6.5 74 140.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120938 Lab ID 57
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 45990 64850 66120 75100
Compressive Strength(psi) 3660 5160 5260 5980
Test Date 04/21/08 05/12/08 05/12/08 06/09/08
Test Age 7 28 28 56
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
57 May 12, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/14/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 15 Air Range(%) 4.5-7.5
Weather/Temperature Clear/40's Temperature(°F) 50-90
Placement Location: Footing at KK/647.5 and BRR.5/B47.5
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Gridline BRR.5/B47.5 6091 32120940 3:42 4:40 5 1/2 4.5 65 145.2
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32120940 Lab ID 58
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 27220 47530 45560
Compressive Strength(psi) 2170 3780 3630
Test Date 04/21/08 05/12/08 05/12/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
58 May 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/17/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 6 1/2 Air Range(%) 4.5-7.5
Weather/Temperature 30's Temperature(°F) 50-90
Placement Location: Grade beam at BEEE.6-W/71.2
Methods Employed: Hopper/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Grade beam at BEEE.6-W/71.2 6095 32121044 12:00 1:00 4 1/2 7.5 62 137.2
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121044 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 28860 43030 43950
Compressive Strength(psi) 2300 3420 3500
Test Date 04/24/08 05/15/08 05/15/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
59 May 16, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3"-8"
Total Cubic Yards Placed: 100 Air Range(%) 4.5-7.5
Weather/Temperature 30's Temperature(°F) 50-90
Placement Location: 2WL of Parking Sturctural Topping at BQQQ4-BTT.9/71-48
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
2WL of Parking Sturctural Topping at BQQQ4-BTT.9/71-48 6095 32121053 7:00 AM 8:15 AM 5 1/2 4.5 62 145.2
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121053 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 53980 74610 78560
Compressive Strength(psi) 4300 5940 6250
Test Date 04/25/08 05/16/08 05/16/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
60 May 16, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3"-8"
Total Cubic Yards Placed: 100 Air Range(%) 4.5-7.5
Weather/Temperature 30's Temperature(°F) 50-90
Placement Location: Footings 1067 and 1082 at W/66514 abd 8/57.2
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footings 1067 and 1082 at W/B6514 abd 8/57.2 6038 32121069 11:00 AM 12:15 PM 5 4.5 65 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121069 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 63970 79560 81020
Compressive Strength(psi) 5090 6330 6450
Test Date 04/25/08 05/16/08 05/16/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
61 May 16, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 75 Air Range(%) 4.5-7.5
Weather/Temperature 40's Temperature(°F) 50-90
Placement Location: Footing 1092 at M/57.2
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1092 at M/57.2 6092 32121083 1:55 PM 3:15 PM 4 1/2 6.5 65 141.2
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 37960 53830 58060
Compressive Strength(psi) 3020 4280 4620
Test Date 04/25/08 05/16/08 05/16/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
62 May 21, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 10 Air Range(%) 4.5-7.5
Weather/Temperature 40's Temperature(°F) 50-90
Placement Location: Level 2 Parking Garage 57.2/BTT.9-BSSS.3
Methods Employed: Crane and Hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Level 2 Parking at 57.2/BTT.9-BSSS.3 6093 32121182 7:15 8:30 7 8.0 65 136.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121182 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 39550 64780 63580
Compressive Strength(psi) 3150 5160 5060
Test Date 04/30/08 05/21/08 05/21/08
Test Age 7 28 28
Type of Fracture Discarded
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
63 May 23, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/25/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 50 Air Range(%) 4.5-7.5
Weather/Temperature 30's Temperature(°F) 50-90
Placement Location: Level 2 Parking Garage BTT.9-BQQQ.4/B57.2-B47.5
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BTT.9-BQQQ.4-657.2-647.5 6095 32121273 7:02 8:15 7 4.0 60 144.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121273 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 50810 72670 77490
Compressive Strength(psi) 4040 5780 6170
Test Date 05/02/08 05/23/08 05/23/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
64 May 7, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 04/30/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 65 Air Range(%) 4.5%
Weather/Temperature 40's Temperature(°F) 50-90
Placement Location: Pad 7,8,&13 at Gridline 66/BTT.9&Footing 1100/F38 at A/43 pad 5&6 at 66/KK
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Pad 7,8,&13 at Gridline 66/BTT.9&Footing 1100/F38 at A/43 6025 32121412 6:58 8:20 4 1/2 4.5 68 144.0
pad 5&6 at 66/KK
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121412 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 27970 42390 37900
Compressive Strength(psi) 2230 3370 3020
Test Date 05/07/08 05/28/08 05/28/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
65 May 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 05/02/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 30 cubic yards Air Range(%) 4.5%
Weather/Temperature Snow/20's Temperature(°F) 50-90
Placement Location: Footing 1099 at C/44
Methods Employed: Hopper/bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1099 at C/44 6092 32121458 7:40 8:45 5 1/2 5.5 65 141.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121458 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 32180 48060 49800
Compressive Strength(psi) 2560 3820 3960
Test Date 05/09/08 05/30/08 05/30/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
66 June 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 05/06/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 6 1/2 Air Range(%) 4.5-7.5%
Weather/Temperature 50's Temperature(°F) 50-90
Placement Location: Mechanical Pad at H/70 and Grade Beam C.5 at C/47.5
Methods Employed: Hopper/bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Pad at H/70 and Grade Beam C.5 at C/47.5 6012 32121606 10:04 11:15 5 5.5 65 140.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121606 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 32000 46860 43730
Compressive Strength(psi) 2550 3730 3480
Test Date 05/13/08 06/03/08 06/03/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
67 June 6, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 05/09/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 52 Air Range(%) 4.5-7.5%
Weather/Temperature 40's Temperature(°F) 50-90
Placement Location: Footing 1101, 1102,and 1098
Methods Employed: Hopper/bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1101 at C/39, 1102 at F/35,and 1098 at D/42 6042 32121712 11:14 12:30 4 1/2 6.0 84 140.0 -
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32121712 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 32230 48050 48760
Compressive Strength(psi) 2560 3820 3880
Test Date 05/16/08 06/06/08 06/06/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
68 June 20, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 05/23/08 Specifications
Concrete Placed By: Concrete Management Corporation Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 75 Air Range(%) 4.5-7.5%
Weather/Temperature Sunny/50's Temperature(°F) 50-90
Placement Location: Gridlines SS to B48.4 and MMM to SSS,slab on grade
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Southwest corner of pour 6093 32122152 7:36 8:35 3 3/4 4.6 65 - 18
Notification of field test results: Jeff&Tom with PCL and CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122152 Lab ID 283
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 36110 51150 54450
Compressive Strength(psi) 2870 4070 4330
Test Date 05/30/08 06/20/08 06/20/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician John Williams
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
69 June 28, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 05/31/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating# Slump Range(in.) N/S
Total Cubic Yards Placed: 66 Air Range(%) 4.5-7.5%
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Slab on grade BTT.9-BZZ.9/B57.2-B65.4
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Slab on grade BTT.9-BZZ.9/B57.2-B65.4 6091 32122388 7:31 8:15 5 1/2 6.5 60 140.0 -
Notification of field test results: Jeff&Tom with PCL and CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122388 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 39360 45570 48150
Compressive Strength(psi) 3130 3630 3830
Test Date 06/07/08 06/28/08 06/28/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
70 July 4, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/06/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37542402 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 290 Air Range(%) 4.5-7.5%
Weather/Temperature Chilly/50's Temperature(°F) 50-90
Placement Location: Slab on grade P.T.
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
662-71/BTT.9-BZZ.9 6038 32122592 6:10 7:15 5 4.5 68 145.0 -
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122592 Lab ID 366
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 53300 77440 95620 94360
Compressive Strength(psi) 4240 6160 7610 7510
Test Date 06/09/08 06/13/08 07/04/08 07/04/08
Test Age 3 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
71 July 4, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/06/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37542402 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 290 Air Range(%) 4.5-7.5%
Weather/Temperature Chilly/50's Temperature(°F) 50-90
Placement Location: Slab on grade P.T.
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BAAA.2-BNNN.8/71-61.9 6041 32122609 9:11 9:30 71/2 4.0 70 144.0 -
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122609 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 59840 76970 92400 95590
Compressive Strength(psi) 4760 6130 7350 7610
Test Date 06/09/08 06/13/08 07/04/08 07/04/08
Test Age 3 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
72 July 4, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/06/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37542402 Slump Range(in.) 7+/-1"
Total Cubic Yards Placed: 290 Air Range(%) 0-3%
Weather/Temperature Chilly/50's Temperature(°F) 50-90
Placement Location: Slab on Deck,Terrace Level
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
B47.5-B57.2/BQQQ.4-BAAA.2 6037 32122622 10:16 11:20 81/2 2.0 70 144.0 -
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122622 Lab ID 365
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 56470 74370 97940 10090
Compressive Strength(psi) 4490 5920 7790 800
Test Date 06/09/08 06/13/08 07/04/08 07/04/08
Test Age 3 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
73 July 4, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/06/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37542402 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 290 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Slab on Deck
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
B47.5-B51.2/BQQQ.4-BAAA.2 6041 32122634 10:15 11:30 8 2.5 70 144.0 -
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 3.212E+09 Lab ID 364
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 61130 79260 84360 86430
Compressive Strength(psi) 4860 6310 6710 6880
Test Date 06/09/08 06/13/08 07/04/08 07/04/08
Test Age 3 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
74 July 9, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/11/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 6 1/2 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Columns on Terrrace Level Deck
Methods Employed: A Bucket/Hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Columns 273,274,and 144 6003 32122819 1:37 2:35 8 4.5 68 140.0 10
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122819 Lab ID 417
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 62690 88640 90670
Compressive Strength(psi) 4990 7050 7220
Test Date 06/18/08 07/09/08 07/09/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Tom and Jeff of the 9"slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
75 July 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/12/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37024550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 80 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Precast composite Topping
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
46-72/C-W 6004 32212844 8:02 9:00 9 3.5 68 144.0 -
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122844 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 69130 75870 73920
Compressive Strength(psi) 5500 6040 5880
Test Date 06/19/08 07/10/08 07/10/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Tom and Jeff of the 9"slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
76 July 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/12/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37024550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 80 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Precast composite Topping
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
46-72/C-W-Super P 6039 32122858 10:41 11:30 7 7.0 65 140.0 80z
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122858 Lab ID 425
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 70130 86760 87940
Compressive Strength(psi) 5580 6900 7000
Test Date 06/19/08 07/10/08 07/10/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Tom and Jeff of the 9"slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
77 July 11, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/13/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 200 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Footing 1215&1103
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1215&1103 6032 3422907 12:00 12:40 7 6.0 68 140.0
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 3422907 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 32370 49250 51320
Compressive Strength(psi) 2580 3920 4080
Test Date 06/20/08 07/11/08 07/11/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Tom of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
78 July 11, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/13/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 200 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Footing 1215&1103
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1215&1103 6042 3212918 12:53 1:45 7 1/2 7.5 65 140.0
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122918 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 30720 52760 55940
Compressive Strength(psi) 2440 4200 4450
Test Date 06/20/08 07/11/08 07/11/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Tom of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
79 July 11, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/13/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 200 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Footing 1215
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1215 6091 32122926 1:50 2:15 5 1/2 7.5 68 140.0
Notification of field test results: Jeff with PCL and Tom with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122926 Lab ID 442
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 34080 51450 50700
Compressive Strength(psi) 2710 4090 4030
Test Date 06/20/08 07/11/08 07/11/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Tom of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
80 July 11, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/13/08 Specifications
Concrete Placed By: Concrete Management Corp. Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 45 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: SW 8 Terrace level deck
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
SW 8 Terrace level deck 6037 32122932 3:25 4:00 5 4.5 65 144.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122932 Lab ID 426
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57 12.57
Maximum Load 67000 62900 78470 112340 110270
Compressive Strength(psi) 5330 5010 6240 8940 8780
Test Date 06/16/08 06/16/08 06/20/08 06/20/08 07/11/08 07111/08
Test Age 3 3 7 7 28 28
Type of Fracture
Additional Comments We notified Tom of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
81 July 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/17/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4+/-1"
Total Cubic Yards Placed: 60 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Footings at RG/R9-R141 and R11/RG-RJ
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing RG/R9-R141 and R11/RG-RJ 6042 32122992 7:18 8:15 4 1/2 5.5 68 144.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122992 Lab ID 464
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 33790 51540 52700
Compressive Strength(psi) 2690 4100 4190
Test Date 06/24/08 07/15/08 07/15/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
82 July 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/17/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#3752401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 23 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Column 407
Methods Employed: Hopper and bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Column 407 6037 32123037 1:12 2:15 7 1/2 6.0 65 140.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123037 Lab ID 465
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 77140 103310 107240
Compressive Strength(psi) 6140 8220 8530
Test Date 06/24/08 07/15/08 07/15/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
83 July 17, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/19/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 81 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: 2nd level topping slab
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
42/C-BEE.6 6038 32123097 7:12 8:30 61/2 6.0 75 140.0
Notification of field test results: Tom with PCL Jeff with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123097 Lab ID 476
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 66970 85560 84170
Compressive Strength(psi) 5330 6810 6700
Test Date 06/26/08 07/17/08 07/17/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
84 July 17, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/19/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 81 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: 2nd level garage topping
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
42/C-BEE.6 6093 32123109 9:22 10:40 61/2 4.5 70 144.0
Notification of field test results: Tom with PCL Jeff with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123109 Lab ID 477
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 86890 108650 110420
Compressive Strength(psi) 6910 8650 8790
Test Date 06/26/08 07/17/08 07/17/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
85 July 17, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/19/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 9 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Terrace level columns:408,407,379, 388,389,and 455
Methods Employed: Hopper/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
52.3/MMM column 407 6093 32123131 3:00 4:30 8 1/2 5.5 68 140.0
Notification of field test results: Tom with PCL Jeff with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123131 Lab ID 478
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 52260 85830 87040
Compressive Strength(psi) 4160 6830 6930
Test Date 06/26/08 07/17/08 07/17/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
86 July 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/20/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 300 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/60's Temperature(°F) 50-90
Placement Location: Footing 1228
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1228 M/28 6038 32123149 9:00 10:00 4 1/2 5.0 68 144.0 10
Notification of field test results: Tom with PCL Jeff with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123149 Lab ID 484
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 34210 52870 50710
Compressive Strength(psi) 2720 4210 4040
Test Date 06/27/08 07/18/08 07/18/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
87 July 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/20/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 300 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/60's Temperature(°F) 50-90
Placement Location: Footing 1228
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1228 M/28 0 32123159 10:13 11:00 5 6.0 70 140.0 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123159 Lab ID 485
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 34030 50330 52830
Compressive Strength(psi) 2710 4010 4200
Test Date 06/27/08 07/18/08 07/18/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
88 July 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/20/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 300 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/60's Temperature(°F) 50-90
Placement Location: Footing 1228
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1228 M/28 0. 32123172 11:40 12:45 3 6.0 68 140.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123172 Lab ID 486
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 37990 56420 59310
Compressive Strength(psi) 3020 4490 4720
Test Date 06/27/08 07/18/08 07/18/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
89 July 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/20/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 300 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/60's Temperature(°F) 50-90
Placement Location: Footijng 1228
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1228 M/28 6091 32123181 12:37 1:30 7 6.5 70 140.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123180 Lab ID 487
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 31010 49230 54890
Compressive Strength(psi) 2470 3920 4370
Test Date 06/27/08 07/18/08 07/18/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
90 July 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/20/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 300 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/60's Temperature(°F) 50-90
Placement Location: Footijng 1228
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1228 M/28 6092 32123189 1:40 2:30 5 5.5 70 140.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123189 Lab ID 488
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 37640 55520 58010
Compressive Strength(psi) 3000 4420 4620
Test Date 06/27/08 07/18/08 07/18/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
91 July 18, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/20/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 3 1/2 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/60's Temperature(°F) 50-90
Placement Location: Column 382
Methods Employed: Hopper/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Column 382 6025 32123196 3:45 5:00 9 6.0 70 140.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123196 Lab ID 483
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 61060 67980 90660 93540
Compressive Strength(psi) 4860 5410 7210 7440
Test Date 06/23/08 06/27/08 07/18/08 07/18/08
Test Age 3 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
92 July 22, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/24/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 30 Air Range(%) 4.5-7.5
Weather/Temperature 60's Temperature(°F) 50-90
Placement Location: Footings 1234, 1235,and 1236
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footings 1234, 1235,and 1236 0 32123330 9:10 10:15 5 5.5 68 142.0 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123330 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 89330 56180 58250
Compressive Strength(psi) 7110 4470 4640
Test Date 07/01/08 07/22/08 07/22/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
93 July 22, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/24/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 40 Air Range(%) 4.5-7.5
Weather/Temperature 70's Temperature(°F) 50-90
Placement Location: Shear walls at 1228 footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Shear walls at 1228 footing 0 32123371 1:40 2:30 8 5.0 68 142.0 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123371 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 84330 110090 111100
Compressive Strength(psi) 6710 8760 8840
Test Date 07/01/08 07/22/08 07/22/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
94 July 23, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/25/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 90 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Footing 1227
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1227 6091 32123418 1:16 2:30 5 5.0 70 142.0 -
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123418 Lab ID 534
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 40040 52620 56280
Compressive Strength(psi) 3190 4190 4480
Test Date 07/02/08 07/23/08 07/23/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
95 July 23, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/25/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 90 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Footing 1238
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1238 6037 32123430 3:03 3:50 5 6.0 70 140.0 -
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123430 Lab ID 535
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 38540 51740 53530
Compressive Strength(psi) 3070 4120 4260
Test Date 07/02/08 07/23/08 07/23/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
96 July 23, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/25/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 9 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Column 199
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Column 199 6037 32123434 4:19 5:00 9 5.0 70 140.0 -
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123434 Lab ID 536
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 70130 91670 94530
Compressive Strength(psi) 5580 7290 7520
Test Date 07/02/08 07/23/08 07/23/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
97 July 24, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/26/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 72 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/60's Temperature(°F) 50-90
Placement Location: Parking structure topping
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Topping at W-BZZ.9/647.5-70 6042 32123449 7:18 8:30 8 7.0 70 140.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123449 Lab ID 543
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 64180 89710 86470
Compressive Strength(psi) 5110 7140 6880
Test Date 07/03/08 07/24/08 07/24/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
98 July 24, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/26/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating#35542430 Slump Range(in.) 4"+/-1
Total Cubic Yards Placed: 39 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Footing 1240 at B/28
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing at B/28 6039 32123503 1:49 2:45 5 1/2 5.0 72 142.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123503 Lab ID 544
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 38580 53390 51680
Compressive Strength(psi) 3070 4250 4110
Test Date 07/03/08 07/24/08 07/24/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
99 July 24, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/26/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 7 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Columns 199 and 200, Level 1
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Columns 199 and 200 6025 32123512 3:06 4:00 8 1/2 4.0 68 144.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123512 Lab ID 545
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 86760 102290 102210
Compressive Strength(psi) 6900 8140 8130
Test Date 07/03/08 07/24/08 07/24/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
100 July 24, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/26/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating# Slump Range(in.) 3-8
Total Cubic Yards Placed: 24 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Footer 1237
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1237 0 32122580 2:19 3:30 9 5.0 72 142.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32122580 Lab ID 581
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 68100 93830 94830
Compressive Strength(psi) 5420 7470 7550
Test Date 07/03/08 07/24/08 07/24/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Jeff with PCL of the high slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
101 July 25, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/27/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 72 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Level 2 parking composite topping
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Level 2 composite topping 0 32123531 7:30 9:15 9 6.0 80 141.0 1
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID 580
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 70200 90860 88520
Compressive Strength(psi) 5590 7230 7040
Test Date 07/04/08 07/25/08 07/25/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Jeff with PCL of the high slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
102 July 28, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 06/30/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 8 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Perimeter Wall
Methods Employed: Hopper/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
6091 32123635 10:25 11:30 8 5.0 70 144.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123635 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 78230 118350 122760
Compressive Strength(psi) 6230 9420 9770
Test Date 07/07/08 07/28/08 07/28/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
103 July 31, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/03/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 50 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Terrace level composite
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Terrace IeveL Topping BTT.9-BEE.6/56-70 6042 32122840 7:16 8:30 9 5.0 72 142.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123840 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 67420 86350 88240
Compressive Strength(psi) 5370 6870 7020
Test Date 07/10/08 07/31/08 07/31/08
Test Age 7 28 28
Type of Fracture
Additional Comments Notified Tom of slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
104 August 5, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/08/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 50 Air Range(%) 4.5-7.5
Weather/Temperature Sunny Temperature(°F) 50-90
Placement Location: Footings: 1028, 1059,and 1034
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1034 at B40.3/BNNN.4 6037 32123965 1:25 2:30 3 5.5 70 140.0 Super P
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123840 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 42960 60630 63490
Compressive Strength(psi) 3420 4820 5050
Test Date 07/15/08 08/05/08 08/05/08
Test Age 7 28 28
Type of Fracture
Additional Comments Notified Tom of slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
105 August 5, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/08/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 8 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Column 406
Methods Employed: Hopper/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Column 406 at B48.4/BQQQ.4 6012 32123998 4:43 5:30 9 5.0 70 143.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32123998 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 71530 92110 92700
Compressive Strength(psi) 5690 7330 7380
Test Date 07/15/08 08/05/08 08/05/08
Test Age 7 28 28
Type of Fracture
Additional Comments Notified Tom and Jeff of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
106 August 6, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/09/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 44 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Footing 1062&1060
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1062 and 1060 0 32124049 12:35 1:45 3 4.5 72 143.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124049 Lab ID 671
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 44050 59560 61950
Compressive Strength(psi) 3510 4740 4930
Test Date 07/16/08 08/06/08 08/06/08
Test Age 7 28 28
Type of Fracture
Additional Comments Notified Tom and Jeff of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
107 August 7, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4+/-1"
Total Cubic Yards Placed: 65 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Footing 1061 &1033
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1061 &1033 0 32124098 1:02 2:00 4 5.5 75 142.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124098 Lab ID 690
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 47260 58120 60570
Compressive Strength(psi) 3760 4630 4820
Test Date 07/17/08 08/07/08 08/07/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
108 August 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/11/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 47 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Footing 1031 &1032
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1031 34/BEEE.8 712 32124198 2:18 3:15 3 3/4 4.4 80 144.0 15
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124198 Lab ID 711
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 42950 56520 55510
Compressive Strength(psi) 3420 4500 4420
Test Date 07/18/08 08/08/08 08/08/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
109 August 12, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/15/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 10 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Slab on Grade
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Slab on Grade at M-P/66-70 6091 32124258 9:06 10:15 3 3/4 5.5 80 145.0 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124258 Lab ID 726
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 34120 61710 62020
Compressive Strength(psi) 2720 4910 4940
Test Date 07/22/08 08/12/08 08/12/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
110 August 12, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/15/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 61 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Footing B.6
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 6.6 6091 32124273 1:01 2:00 5 5.5 78 140.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124273 Lab ID 727
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 33800 52810 52790
Compressive Strength(psi) 2690 4200 4200
Test Date 07/22/08 08/12/08 08/12/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
111 August 13, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/16/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 46 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Footing 1168
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1168 6092 32124331 1:10 2:10 4 1/4 5.3 82 142.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124331 Lab ID 731
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 42540 63560 61810
Compressive Strength(psi) 3390 5060 4920
Test Date 07/23/08 08/13/08 08/13/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
112 August 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/18/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 220 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Slab on Grade 3 and 2A
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Slab on grade at H/65 6091 32124437 7:00 8:00 5 1/4 4.8 75 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124437 Lab ID 771
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 42760 59370 60510
Compressive Strength(psi) 3400 4720 4820
Test Date 07/25/08 08/15/08 08/15/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
113 August 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/18/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4+/-1"
Total Cubic Yards Placed: 220 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Slab on Grade 3 and 2A
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Slab on grade at 65/Y 6036 32124458 9:26 10:20 5 1/2 6.0 75 141.0 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124458 Lab ID 772
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 34830 52710 49930
Compressive Strength(psi) 2770 4190 3970
Test Date 07/25/08 08/15/08 08/15/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
114 August 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/18/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 220 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Footings 1173, 1167, 1105,and B.7
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1173 6038 32124484 1:32 2:15 4 1/4 5.0 75 143.0 -
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124484 Lab ID 773
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 50980 67360 67170
Compressive Strength(psi) 4060 5360 5350
Test Date 07/25/08 08/15/08 08/15/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
115 August 19, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/22/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 9 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: S.O.G.
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
S.O.G.at pour 3 Mechanical Room 0 32124621 9:08 10:00 4 3/4 5.8 72 143.0 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124621 Lab ID 804
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 37890 53560 54580
Compressive Strength(psi) 3020 4260 4340
Test Date 07/29/08 08/19/08 08/19/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
116 August 21, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/24/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 130 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: S.O.G.
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
S.O.G.at 51/R 0 32124686 7:21 8:15 5 3/4 4.6 75 142.4 Super P
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124686 Lab ID 834
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 35600 57490 60120
Compressive Strength(psi) 2830 4570 4780
Test Date 07/31/08 08/21/08 08/21/08
Test Age 7 28 28
Type of Fracture
Additional Comments Tom was notified of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
117 August 21, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/24/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4:+/-1":
Total Cubic Yards Placed: 140 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: S.O.G.
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
S.O.G.at 51/P 6036 32124708 9:30 10:55 3 3/4 5.6 70 142.0 Super P&1
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124708 Lab ID 835
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 31300 59920 62990
Compressive Strength(psi) 2490 4770 5010
Test Date 07/31/08 08/21/08 08/21/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
118 August 21, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/24/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4+/-1":
Total Cubic Yards Placed: 140 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: Footings
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1106 6003 32124726 11:58 12:45 3 4.3 70 145.2 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124726 Lab ID 836
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 35930 69810 68990
Compressive Strength(psi) 2860 5560 5490
Test Date 07/31/08 08/21/08 08/21/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Aftn:
119 August 22, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/25/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4+/-1":
Total Cubic Yards Placed: 27 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: Footings
Methods Employed: Bucket/Hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1164 at 23.4/BAAA.2 6039 32124759 1:24 2:15 4 1/2 6.2 72 141.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124759 Lab ID 842
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 47420 57820 61320
Compressive Strength(psi) 3770 4600 4880
Test Date 08/01/08 08/22/08 08/22/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
120 August 25, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/28/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4+/-1":
Total Cubic Yards Placed: 68 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: Footings
Methods Employed: Bucket/Hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1111 at B23/BNNN.4 6093 32124775 12:55 1:20 3 3/4 5.2 72 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124775 Lab ID 851
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 34450 53200 57430
Compressive Strength(psi) 2740 4230 4570
Test Date 08/04/08 08/25/08 08/25/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
121 August 26, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/29/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4+/-1":
Total Cubic Yards Placed: 72 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: Footings,Area 5
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1133 at 1.1/RRR 6091 32124811 1:14 2:15 5 1/4 6.4 75 142.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124811 Lab ID 860
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 29430 50620 47900
Compressive Strength(psi) 2340 4030 3810
Test Date 08/05/08 08/26/08 08/26/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
122 August 27, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/30/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4+/-1"
Total Cubic Yards Placed: 70 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1129 at 1.4/RRR 6041 32124842 12:54 1:50 4 3/4 6.5 70 142.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124842 Lab ID 869
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 44670 57830 57520
Compressive Strength(psi) 3550 4600 4580
Test Date 08/06/08 08/27/08 08/27/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Aftn:
123 August 28, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 07/31/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 45 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Parking Structure topping 1 st level
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Topping 24-42.8/R-RG 6037 32124852 6:52 8:00 8 5.4 68 144.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124852 Lab ID 881
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 68480 77000 78370
Compressive Strength(psi) 5450 6130 6240
Test Date 08/07/08 08/28/08 08/28/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
124 August 29, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/01/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 80 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: S.O.G.24-44/RG-F
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
S.O.G.24/RG 6037 32124909 7:02 8:15 41/4 5.7 72 143.0 15
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124909 Lab ID 902
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 41230 54520 51940
Compressive Strength(psi) 3280 4340 4130
Test Date 08/08/08 08/29/08 08/29/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
125 August 29, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/01/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 80 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: S.O.G.
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
S.O.G.24-44/RG-F 6039 32124931 9:42 10:30 5 6.2 70 143.0 15
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124931 Lab ID 903
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 35700 52150 53840
Compressive Strength(psi) 2840 4150 4280
Test Date 08/08/08 08/29/08 08/29/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
126 August 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/01/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 40 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footings
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing B.16 6005 32124959 1:09 2:00 5 1/4 6.0 70 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32124959 Lab ID 904
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 29940 41030 39780
Compressive Strength(psi) 2380 3270 3170
Test Date 08/08/08 08/29/08 08/29/08
Test Age 7 28 28
Type of Fracture
Additional Comments We notified Tom of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
127 September 2, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/05/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 8 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footings
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footers 1128 at B2.4/QQQ 8038 32125041 9:17 10:00 8 1/2 7.0 68 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125041 Lab ID 923
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 69320 86460 89700
Compressive Strength(psi) 5520 6880 7140
Test Date 08/12/08 09/02/08 09/02/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
128 August 12, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/05/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 43 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footings
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footers 1128 at B2.4/QQQ 6041 32125054 12:27 1:30 3 7.2 70 144.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125054 Lab ID 924
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 42540 63220 64200
Compressive Strength(psi) 3390 5030 5110
Test Date 08/12/08 09/02/08 09/02/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
129 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 35542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BQQQ.4-BEEE.6/617.5-71 6042 32125077 6:28 7:45 10 7.5 65 137.4
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125077 Lab ID 937
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57 12.57
Maximum Load 59840 59510 75630 74080 76060
Compressive Strength(psi) 4760 4740 6020 5900 6050
Test Date 08/13/08 08/13/08 09/03/08 09/03/08 09/03/08
Test Age 7 7 28 28 28
Type of Fracture
Additional Comments We notified Tom of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
130 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 35542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/50's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
GL MMM-69 0 32125078 6:40 7:49 10 1/2 6.8 72 136.5
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125078 Lab ID 938
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57 12.57
Maximum Load 47560 53540 77540 76070 83610
Compressive Strength(psi) 3780 4260 6170 6050 6650
Test Date 08/09/08 08/13/08 09/03/08 09/03/08 10/01/08
Test Age 3 7 28 28 56
Type of Fracture
Additional Comments Field Technician Stephen Buckeridge
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
131 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 35542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/50's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
GL NNN-65 6036 32125086 7:22 8:22 10 1/4 7.2 71 135.0 10
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125086 Lab ID 943
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57 12.57
Maximum Load 58440 55620 76980 74050 76130
Compressive Strength(psi) 4650 4430 6130 5890 6060
Test Date 08/13/08 08/13/08 09/03/08 09/03/08 09/03/08
Test Age 7 7 28 28 28
Type of Fracture
Additional Comments Field Technician Stephen Buckeridge
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
132 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Post Tension Deck BQQQ.4-BEEE.4/B47.5-71 6004 32125091 8:17 8:56 9 1/2 7.0 68 139.0
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125091 Lab ID 936
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 62000 60820 82950 85170
Compressive Strength(psi) 4930 4840 6600 6780
Test Date 08/13/08 08/13/08 09/03/08 09/03/08
Test Age 7 7 28 28
Type of Fracture
Additional Comments Tom was notified of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
133 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/60's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
GL GGG 61 6041 32125097 8:50 9:42 9 6.6 75 138.8 5
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125097 Lab ID 942
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 62780 65240 85450 86970
Compressive Strength(psi) 5000 5190 6800 6920
Test Date 08/13/08 08/13/08 09/03/08 09/03/08
Test Age 7 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
134 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Post Tension Deck Level 1 6037 32125106 9:43 10:30 9 1/4 7.5 72 134.4
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125106 Lab ID 935
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 62490 59810 82810 86230
Compressive Strength(psi) 4970 4760 6590 6860
Test Date 08/13/08 08/13/08 09/03/08 09/03/08
Test Age 7 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
135 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Cloudy/60's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
GL GGG-58 6004 32125107 9:48 10:42 9 3/4 6.8 75 136.8
Notification of field test results: Tom with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125107 Lab ID 941
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 64170 63550 80920 83670
Compressive Strength(psi) 5110 5060 6440 6660
Test Date 08/13/08 08/13/08 09/03/08 09/03/08
Test Age 7 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
136 October 1, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Cloudy/60's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Post Tension Deck Level 1 BQQQ.6/B47.5-71 6041 32125115 10:37 11:30 10 7.6 70 136.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125115 Lab ID 934
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57 12.57
Maximum Load 42050 45140 55370 59190 84190
Compressive Strength(psi) 3350 3590 4410 4710 6700
Test Date 08/13/08 08/13/08 09/03/08 09/03/08 09/30/08
Test Age 7 7 28 28 55
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
137 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Cloudy/60's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
GL NNN-55 6025 32125117 10:48 11:41 9 7.5 79 135.8 5
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125117 Lab ID 940
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 58210 59660 81880 78950
Compressive Strength(psi) 4630 4750 6520 6280
Test Date 08/13/08 08/13/08 09/03/08 09/03/08
Test Age 7 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
138 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Cloudy/70's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
GL EEE-55 0 32125124 11:41 12:39 10 7.0 80 137.0 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125124 Lab ID 939
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 56150 57520 81590 81780
Compressive Strength(psi) 4470 4580 6490 6510
Test Date 08/13/08 08/13/08 09/03/08 09/03/08
Test Age 7 7 28 28
Type of Fracture
Additional Comments Field Technician Stephen Buckeridge
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
139 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Post Tension Deck Level 1-BQQQ.4-BEEE.6/B47.5 6025 32125132 12:11 12:50 9 1/4 7.4 73 137.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125132 Lab ID 933
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 64750 68090 83190 79600
Compressive Strength(psi) 5150 5420 6620 6330
Test Date 08/13/08 08/13/08 09/03/08 09/03/08
Test Age 7 7 28 28
Type of Fracture
Additional Comments Field Technician Stephen Buckeridge
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
140 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Cloudy/60's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
GL EEE-47 0 32125142 1:22 2:01 10 1/4 5.5 76 140.5 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125142 Lab ID 944
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 60400 62610 84060 82130
Compressive Strength(psi) 4810 4980 6690 6540
Test Date 08/13/08 08/13/08 09/03/08 09/03/08
Test Age 7 7 28 28
Type of Fracture
Additional Comments Field Technician Stephen Buckeridge
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
141 September 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/06/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 800 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Terrace Level Post Tension Deck
Methods Employed: Pump truck,a vibrator,and finish
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Post Tension Deck Level 1 at BQQQ.4-BEEE.6/647.5-71 0 32125146 1:42 2:30 9 1/2 7.5 75 138.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125146 Lab ID 932
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57 12.57
Maximum Load 58330 53200 74220 76080 77010
Compressive Strength(psi) 4640 4230 5910 6050 6130
Test Date 08/13/08 08/13/08 09/03/08 09/03/08 09/03/08
Test Age 7 7 28 28 28
Type of Fracture
Additional Comments We notified Tom of the slump Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
142 September 4, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/07/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 24 Air Range(%) 4.5-7.5
Weather/Temperature Raining/70's Temperature(°F) 50-90
Placement Location: Footings
Methods Employed: Chute
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer B.14 6091 32125235 1:44 2:30 3 1/2 5.4 70 144.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125235 Lab ID 964
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 41430 62390 63900
Compressive Strength(psi) 3300 4960 5090
Test Date 08/14/08 09/04/08 09/04/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
143 September 5, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/08/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 100 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footer
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1150 at 5/BEEE.8 0 32125282 12:01 1:00 5 3/4 5.5 70 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125282 Lab ID 971
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 74240 89550 89310
Compressive Strength(psi) 5910 7130 7110
Test Date 08/15/08 09/05/08 09/05/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
144 September 5, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/08/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 100 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footer 1150
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1150 at 5/BEEE.8 0 32125289 1:28 2:25 8 4.6 72 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125289 Lab ID 972
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 74420 89910 91620
Compressive Strength(psi) 5920 7150 7290
Test Date 08/15/08 09/05/08 09/05/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
145 September 5, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/08/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 100 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footer 1150
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1150 at 5/BEEE.8 6037 32125298 2:21 3:00 6 4.7 70 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125298 Lab ID 973
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 69580 85510 89170
Compressive Strength(psi) 5540 6800 7100
Test Date 08/15/08 09/05/08 09/05/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
146 September 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/11/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 14 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Columns 447,448,455
Methods Employed: A bucket and hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Column 447 at R14/RP 6012 32125346 11:35 12:10 8 5.9 72 139.2
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125346 Lab ID 976
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 60800 74289 88440 85340
Compressive Strength(psi) 4840 5910 7040 6790
Test Date 08/14/08 08/18/08 09/08/08 09/08/08
Test Age 3 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
147 September 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/11/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 4"+/-1"
Total Cubic Yards Placed: 12 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footer 1202
Methods Employed: A bucket and hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1202 at 5/W 6092 32125360 12:30 2:00 3 3/4 4.5 75 144.0 15
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125360 Lab ID 977
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 34230 51040 50530
Compressive Strength(psi) 2720 4060 4020
Test Date 08/18/08 09/08/08 09/08/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
148 September 9, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/12/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 65 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Composite Topping-Upper Basement Level
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Topping at H/642 6037 32125312 7:05 8:15 8 1/4 5.4 72 143.0
Notification of field test results: Jeff with PCL tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125312 Lab ID 993
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 65180 82370 85420
Compressive Strength(psi) 5190 6550 6800
Test Date 08/19/08 09/09/08 09/09/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
149 August 19, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/12/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 6 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Columns
Methods Employed: A bucket/hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Column 445 at RP/R14 6005 32125400 1:08 2:10 9 6.0 72 137.6
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125400 Lab ID 994
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 59060 71250 70910 85390
Compressive Strength(psi) 4700 5670 5640 6800
Test Date 08/19/08 09/09/08 09/09/08 10/07/08
Test Age 7 28 28 56
Type of Fracture T5 T5 T5
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
150 September 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/13/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 65 Air Range(%) 4.5-7.5
Weather/Temperature Clear/70's Temperature(°F) 50-90
Placement Location: Compsite Topping
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Topping 1 Level at 24/H 6037 32125409 6:54 8:10 6 3/4 6.1 72 -
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125409 Lab ID 995
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 71770 88960 85550
Compressive Strength(psi) 5710 7080 6810
Test Date 08/20/08 09/10/08 09/10/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
151 September 10, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/13/08 Specifications
Concrete Placed By: CMC Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating Slump Range(in.) 3-8
Total Cubic Yards Placed: 65 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Columns
Methods Employed: A bucket/hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Column 457 at 50/ZZ 0042 32125439 1:25 2:15 9 5.9 75 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125439 Lab ID 996
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 53560 71840 103420 105810
Compressive Strength(psi) 4260 5720 8230 8420
Test Date 08/16/08 08/20/08 09/10/08 09/10/08
Test Age 3 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
152 August 21, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/14/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: 40 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Shearwall#7
Methods Employed: A bucket/hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Shear Wall#7 at 660/BAAA.2 6091 32125512 1:08 2:00 9 5.9 75 143.0
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125512 Lab ID 1038
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 65580 90000 88920
Compressive Strength(psi) 5220 7160 7080
Test Date 08/21/08 09/11/08 09/11/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
153 September 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 170 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footings 1064, 1122, 1126,&1183
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footings 1122 6003 32125603 1:34 2:35 6 5.9 70 141.6
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125603 Lab ID 1041
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 61890 75900 76850
Compressive Strength(psi) 4930 6040 6120
Test Date 08/25/08 09/15/08 09/15/08
Test Age 7 28 28
Type of Fracture T5 T5
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
154 September 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 170 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footings 1064, 1122, 1126,&1183
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1064 6093 32125599 12:17 1:10 5 5.2 61 140.2
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125599 Lab ID 1042
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 62580 80440 84290
Compressive Strength(psi) 4980 6400 6710
Test Date 08/25/08 09/15/08 09/15/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
155 September 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 170 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footings 1064, 1122, 1126,&1183
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1183 6003 32125621 3:45 4:45 5 5.9 69 142.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125621 Lab ID 1040
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 62460 79400 80030
Compressive Strength(psi) 4970 6320 6370
Test Date 08/25/08 09/15/08 09/15/08
Test Age 7 28 28
Type of Fracture T5 T5
Additional Comments Field Technician
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
156 September 17, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/20/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 120 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footings 1124 and 1178
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1124 at 68.5/QQQ 6039 32125703 1:38 2:45 6 1/2 4.9 75 143.0 10
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125703 Lab ID 1063
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 61520 79180 79910
Compressive Strength(psi) 4900 6300 6360
Test Date 08/27/08 09/17/08 09/17/08
Test Age 7 28 28
Type of Fracture T5 T5
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
157 September 17, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/20/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 120 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footings 1124 and 1178
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1178 at 13/BTT.9 6037 32125708 2:43 3:45 6 3/4 5.9 72 141.0 -
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125708 Lab ID 1064
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 61980 75120 76490
Compressive Strength(psi) 4930 5980 6090
Test Date 08/27/08 09/17/08 09/17/08
Test Age 7 28 28
Type of Fracture T5 T5
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
158 September 19, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/22/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 120 Air Range(%) 4.5-7.5
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footers
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1063 6039 32125830 12:30 1:45 5 4.5 75 144.0 -
Notification of field test results: Jeff with PCL Tom with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125830 Lab ID 1079
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 73170 96830 96150
Compressive Strength(psi) 5820 7710 7650
Test Date 08/29/08 09/19/08 09/19/08
Test Age 7 28 28
Type of Fracture T5 T5
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
159 September 19, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/22/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 192 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: Footers
Methods Employed: A bucket/hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer of placing boom at B39/Y 6042 32125841 1:38 3:00 5 1/4 4.5 75 143.0 -
Notification of field test results: Jeff with PCL David with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125841 Lab ID 1080
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 76040 86020 88830
Compressive Strength(psi) 6050 6850 7070
Test Date 08/29/08 09/19/08 09/19/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
160 September 19, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/22/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 192 Air Range(%) 4.5-7.5
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: Footers
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1187 at 6/BZZ.5 0 32125846 2:39 4:00 6 3/4 4.5 75 143.0 -
Notification of field test results: Jeff with PCL David with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125846 Lab ID 1082
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 62190 80110 81960
Compressive Strength(psi) 4950 6370 6520
Test Date 08/29/08 09/19/08 09/19/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
161 September 19, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/22/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 192 Air Range(%) 4.5-7.5%
Weather/Temperature 80's Temperature(°F) 50-90
Placement Location: Footer 1187
Methods Employed: A pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1187 at 6/BZZ.5 6037 32125857 3:26 4:30 7 1/4 4.8 75 144.0 -
Notification of field test results: Jeff with PCL David with
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125857 Lab ID 1081
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 65940 85840 84200
Compressive Strength(psi) 5250 6830 6700
Test Date 08/29/08 09/19/08 09/19/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
162 September 23, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/26/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 36042478 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 33 Air Range(%) 4.5-7.5%
Weather/Temperature Sunny/80's Temperature(°F) 50-90
Placement Location: Footer
Methods Employed: A bucket/Hopper
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footer 1177 at B17.7/BTT.9 6005 32125973 12:12 1:20 4 3/4 1.6 75 145.0 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32125973 Lab ID 1115
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 41720 70710 67410
Compressive Strength(psi) 3320 5630 5360
Test Date 09/02/08 09/23/08 09/23/08
Test Age 7 28 28
Type of Fracture T5 T5 T3
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
163 September 26, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 08/29/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 44 Air Range(%) 4.5-7.5%
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Composite Topping/Slab on Deck
Methods Employed: pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Slab on Deck W/59 6093 32126102 8:13 9:45 4 4.5 72 145.0 -
Notification of field test results: Dave with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126102 Lab ID 1159
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 70750 80450 82070
Compressive Strength(psi) 5630 6400 6530
Test Date 09/05/08 09/26/08 09/26/08
Test Age 7 28 28
Type of Fracture
Additional Comments Field Technician James Ford
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
164 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/02/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 174 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footing 1154 Lower haif
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1154 lower half 6039 32126170 1:27 2:15 5 1/2 5.2 69 - -
Notification of field test results: Dave with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126170 Lab ID
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 68450 98130 92230
Compressive Strength(psi) 5450 7810 7340
Test Date 09/09/08 09/30/08 09/30/08
Test Age 7 28 28
Type of Fracture T5 T5 T3
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
165 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/02/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 174 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/80's Temperature(°F) 50-90
Placement Location: Footing 1154 Lower haif
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1154 lower half 6092 32126184 2:30 3:15 6 6.1 70 - -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126184 Lab ID 1170
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 57120 86080 90810
Compressive Strength(psi) 4550 6850 7230
Test Date 09/09/08 09/30/08 09/30/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
166 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/02/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 172 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/70's Temperature(°F) 50-90
Placement Location: Footing 1154 Lower haif
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1154 lower half 6091 32126191 4:13 5:10 5 3/4 6.0 67 - -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126191 Lab ID 1171
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 57300 86460 89390
Compressive Strength(psi) 4560 6880 7110
Test Date 09/09/08 09/30/08 09/30/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
167 October 2, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/04/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 112 Air Range(%) 4.5-7.5%
Weather/Temperature Sunny/81 Degrees F Temperature(°F) 50-90
Placement Location: Placing Boom#3 Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Gridline 12, BAAA.2 and BEEE.8 6039 32126283 2:57 4:15 6 1/2 5.6 67 - -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126283 Lab ID 1166
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 60300 85140 86540
Compressive Strength(psi) 4800 6780 6890
Test Date 09/11/08 10/02/08 10/02/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician April Wyatt
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
168 October 2, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/04/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 112 Air Range(%) 4.5-7.5%
Weather/Temperature Sunny/78 Degrees F Temperature(°F) 50-90
Placement Location: Placing Boom#3 Footing
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
B17.7, BAAA.2 to BEEE.8 6004 32126275 2:06 3:10 5 5.6 67 - -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126275 Lab ID 1167
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 60230 80890 84120
Compressive Strength(psi) 4790 6440 6690
Test Date 09/11/08 10/02/08 10/02/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician April Wyatt
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
169 October 2, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/04/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 300 Air Range(%) 4.5-7.5%
Weather/Temperature Sunny/70 Degrees F Temperature(°F) 50-90
Placement Location: Topping slab Area 2,Terrace Level
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
D,52.3 0 32126246 10:00 10:35 9 1/2 7.1 65 - -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126246 Lab ID 1172
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 76340 94140 92100
Compressive Strength(psi) 6070 7490 7330
Test Date 09/11/08 10/02/08 10/02/08
Test Age 7 28 28
Type of Fracture T3 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
170 October 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/05/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 111 Air Range(%) 4.5-7.5%
Weather/Temperature Clear Temperature(°F) 50-90
Placement Location: Footing 1154 Upper haif
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1154 0 32126342 3:45 4:42 6 1/2 5.9 74 140.2 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126342 Lab ID 1168
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 70290 91610 87730
Compressive Strength(psi) 5590 7290 6980
Test Date 09/12/08 10/03/08 10/03/08
Test Age 7 28 28
Type of Fracture T6 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
171 October 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/05/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 111 Air Range(%) 4.5-7.5%
Weather/Temperature Clear Temperature(°F) 50-90
Placement Location: Footing 1154 Upper haif, 1190
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1190 3 32126336 12:58 1:30 6 4.9 72 143.8 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126342 Lab ID 1173
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 41030 97920 94330
Compressive Strength(psi) 3270 7790 7510
Test Date 09/12/08 10/03/08 10/03/08
Test Age 7 28 28
Type of Fracture T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
172 October 7, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/09/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: Air Range(%) 4.5-7.5%
Weather/Temperature Clear/70'S Temperature(°F) 50-90
Placement Location: Footing 1174
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1174 6012 32126421 1:20 2:15 8 5.0 70 139.8 10
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126421 Lab ID 1184
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 69500 88390 84310
Compressive Strength(psi) 5530 7030 6710
Test Date 09/16/08 10/07/08 10/07/08
Test Age 7 28 28
Type of Fracture T5 T3 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
173 October 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 80 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/70's Temperature(°F) 50-90
Placement Location: Slab on Grade-Garage Level 42-49,A to M
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
43/6.7 0 - 6:58 8:15 61/2 5.6 72 143.1 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID 1193
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 42680 56170 59730
Compressive Strength(psi) 3400 4470 4750
Test Date 09/17/08 10/08/08 10/08/08
Test Age 7 28 28
Type of Fracture T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
174 September 17, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 80 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/70's Temperature(°F) 50-90
Placement Location: Slab on Grade-Garage Level 42-49,A to M
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
44/D.5� 6041 32126443 9:11 10:45 71/2 6.1 70 140.6 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126443 Lab ID 1194
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 39100 59170 54760
Compressive Strength(psi) 3110 4710 4360
Test Date 09/17/08 10/08/08 10/08/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
175 October 8, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/10/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 70 Air Range(%) 4.5-7.5%
Weather/Temperature Raining/50's Temperature(°F) 50-90
Placement Location: Footings 1193, 1171
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1193 9 4.5 67 140.2
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID 1195
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 62830 75320 75510
Compressive Strength(psi) 5000 5990 6010
Test Date 09/17/08 10/08/08 10/08/08
Test Age 7 28 28
Type of Fracture T5 T5
Additional Comments Field Technician Nathan Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
176 October 9, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/11/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 75 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/40's Temperature(°F) 50-90
Placement Location: Slab on Deck, Garden Level R/SS.9, B29/B62
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Slab on Deck,Garden Level R.5/B31 6093 32126457 7:00 8:15 7 4.8 61 143.6 7
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126457 Lab ID 1190
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 62240 82360 78140
Compressive Strength(psi) 4950 6550 6220
Test Date 09/18/08 10/09/08 10/09/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
177 October 9, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/11/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 75 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Slab on Deck, Garden Level R/SS.9, B29/B62
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
J.5/SS Slab on Deck, Garden Level 6004 32126489 9:57 11:10 5 1/2 3.5 65 144.2 10
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126489 Lab ID 1191
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 73700 81450 82350
Compressive Strength(psi) 5860 6480 6550
Test Date 09/18/08 10/09/08 10/09/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
178 October 9, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/11/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 75 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Footings 1192 and 1172
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Footing 1192 0 32126516 1:56 3:35 9 1/2 4.1 70 145.6
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126516 Lab ID 1192
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 75790 91220 95460
Compressive Strength(psi) 6030 7260 7600
Test Date 09/18/08 10/09/08 10/09/08
Test Age 7 28 28
Type of Fracture T3 T6 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
179 October 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/17/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 80 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Slab on grade garage Ievel pour 7
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
634/H 0 32126630 6:55 8:15 61/2 4.9 70 140.9 8
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126516 Lab ID 1257
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 38320 58030 58120
Compressive Strength(psi) 3050 4620 4630
Test Date 09/24/08 10/15/08 10/15/08
Test Age 7 28 28
Type of Fracture T3 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
180 October 15, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/17/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 80 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Slab on grade garage Ievel pour 7
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
S2.3/M 5 32126648 9:26 11:10 4 4.6 70 142.1
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126516 Lab ID 1258
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 38340 54010 57110
Compressive Strength(psi) 3050 4300 4540
Test Date 09/24/08 10/15/08 10/15/08
Test Age 7 28 28
Type of Fracture T5 T5 T6
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
181 September 24, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/17/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 5 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Stairs Garage Level to the first level
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Stairs/Garage Level 4 3/4 5.0 69 141.5
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: Lab ID 1259
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 34300 55230 51970 72320
Compressive Strength(psi) 2730 4400 4140 5760
Test Date 09/24/08 10/15/08 10/15/08 11/12/08
Test Age 7 28 28 56
Type of Fracture T5 T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
182 September 25, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 110 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Slab on deck,garage Ievel,pour#14 and 8
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
35/JJJ 6039 32126676 7:43 8:30 51/2 5.9 68 143.6
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126676 Lab ID 1275
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 39980 53560 57530
Compressive Strength(psi) 3180 4260 4580
Test Date 09/25/08 10/16/08 10/16/08
Test Age 7 28 28
Type of Fracture T6
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
183 September 25, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/18/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-5"
Total Cubic Yards Placed: 22 Air Range(%) 4.5-7.5%
Weather/Temperature Clear Temperature(°F) 50-90
Placement Location: Slab on Grade, Pour#15
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
35/Y 6038 32126734 9:46 10:35 6 7.1 71 140.0
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126734 Lab ID 1274
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 37480 55910 59870
Compressive Strength(psi) 2980 4450 4760
Test Date 09/25/08 10/16/08 10/16/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
184 September 26, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/19/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 110 Air Range(%) 4.5-7.5%
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Slab on Grade, Garage Level, Pour#14 and 8
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
48/HHH 6038 32126687 9:11 10:45 61/2 6.5 70 139.8
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126687 Lab ID 1276
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 38110 55890 56530
Compressive Strength(psi) 3030 4450 4500
Test Date 09/26/08 10/17/08 10/17/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
185 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BTT.7-71 6038 32126817 6:08 7:37 101/2 4.8 60 142.7 20
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126817 Lab ID 1303
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 73790 94360 92280
Compressive Strength(psi) 5870 7510 7340
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
186 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
KK-69 6092 32126825 7:25 8:27 9 3/4 1.3 63 144.9 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126825 Lab ID 1304
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 79230 94460 97530
Compressive Strength(psi) 6300 7520 7760
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
187 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
R-70 6038 32126830 8:06 9:11 11 1.7 61 144.8 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126830 Lab ID 1305
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 77370 92610 97850
Compressive Strength(psi) 6160 7370 7790
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T3
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
188 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Y-67 6012 32126836 9:20 10:18 91/4 2.2 60 144.0 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126836 Lab ID 1306
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 77630 98260 97260
Compressive Strength(psi) 6180 7820 7740
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
189 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BEEE-67 6041 32126842 10:11 11:09 101/2 1.1 67 145.2 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126842 Lab ID 1307
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 84380 99960 105410
Compressive Strength(psi) 6710 7950 8390
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
190 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BLL-64 6012 32126847 11:15 11:54 9 3/4 3.6 65 143.4 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126847 Lab ID 1308
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 71730 93470 93790
Compressive Strength(psi) 5710 7440 7460
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
191 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
KK-61 6041 32126852 11:46 12:52 10 2.1 66 144.6 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126852 Lab ID 1309
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 69850 89790 94210
Compressive Strength(psi) 5560 7150 7500
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
192 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BHHH.9-B57.2 - 32126858 12:33 1:51 101/2 1.7 71 145.0 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126858 Lab ID 1310
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 71020 91390 92400
Compressive Strength(psi) 5650 7270 7350
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
193 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Y-56 6041 32126865 1:18 2:07 11 2.4 68 144.4 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126865 Lab ID 1311
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 75780 101220 99730
Compressive Strength(psi) 6030 8050 7940
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
194 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BTT-49 - 32126871 1:54 2:44 10 1.4 68 144.9 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126871 Lab ID 1312
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 79870 94400 95920
Compressive Strength(psi) 6360 7510 7630
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
195 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BHHH.9-648.4 6025 32126875 2:40 3:41 101/2 1.3 73 145.1 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126875 Lab ID 1313
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 79910 96990 100460
Compressive Strength(psi) 6360 7720 7990
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T6
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
196 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
BLL.8-48 41 32126879 3:06 4:27 91/4 1.6 69 144.7 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126879 Lab ID 1314
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 70220 98070 98140
Compressive Strength(psi) 5590 7800 7810
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
197 September 30, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/23/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37342400 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 670 Air Range(%) N/A
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: 1st Floor, Pour 1 at(BTT.9-P)-(647.5-72)
Methods Employed: Pump Truck and Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Y-48 895 32126887 3:49 5:27 11 2.8 70 144.1 5
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126887 Lab ID 1315
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 68010 101580 98080
Compressive Strength(psi) 5410 8080 7800
Test Date 09/30/08 10/21/08 10/21/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
198 October 1, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/24/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 3000
Concrete Supplier/Mix ID: B&B Excavating 35542430 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 50 Air Range(%) 4.5-7.5
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Garage Level slab on grade Pour#9
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Garage Level slab on grade Gridline JJJ/1.4 6093 32126915 9:07 10:10 6 4.9 68 142.6 15
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126915 Lab ID 1277
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 39610 59550 62490
Compressive Strength(psi) 3150 4740 4970
Test Date 10/01/08 10/22/08 10/22/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
199 October 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/26/08 Specifications
Concrete Placed By: PCL/CMC Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating 37042550 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 60 Air Range(%) 4.5-7.5
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Upper level,Garage Precast Area 3, Pour 2
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
34/SS 6042 32126992 7:10 8:15 101/2 5.2 70 - -
34/SS at Point of Placement - - - - 7 - - -
Notification of field test results: Jeff/Troy with PCL and Ronnie with CMC
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32126992 Lab ID 1291
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 79980 103740 107650
Compressive Strength(psi) 6360 8260 8570
Test Date 10/03/08 10/24/08 10/24/08
Test Age 7 28 28
Type of Fracture
Additional Comments The second slump was sampled at the Point of placement Field Technician Nate Fintei
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
200 October 3, 2008 Mr. David Williams
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/26/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating 37542401 Slump Range(in.) 3-8
Total Cubic Yards Placed: - Air Range(%) 4.5-7.5
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: 1 st Level Columns 473,479,478,477,468,467,425,472,472,474,475,and 427
Methods Employed: Crane/Bucket
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
1st Level Columns 473" 6005 32127056 1:47 2:57 11 - - - -
1 st Level Columns 473 6038 32127065 2:57 4:45 9 5.1 67 - -
Notification of field test results: Jeff/Troy with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32127065 Lab ID 1292
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 95810 136100 130860
Compressive Strength(psi) 7620 10830 10410
Test Date 10/03/08 10/24/08 10/24/08
Test Age 7 28 28
Type of Fracture
Additional Comments "=indicates that the load was rejected by PCL Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
201 October 7, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/30/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: Lafarge RMXAGC65GF8 Slump Range(in.) 22-26
Total Cubic Yards Placed: 22 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/50's Temperature(°F) 50-90
Placement Location: Columns 473,479,478,477,468,467,468,467,471,474,472
Methods Employed: Pump Truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Columns 479 4780612 85908300 8:04 9:54 31 5.3 68 141.0 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 85908300 Lab ID 1347
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 86510 123060 116610
Compressive Strength(psi) 6880 9790 9280
Test Date 10/07/08 10/28/08 10/28/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
202 October 7, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 09/30/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37542401 Slump Range(in.) 3-8"
Total Cubic Yards Placed: 38 Air Range(%) 4.5-7.5
Weather/Temperature Sunny/70's Temperature(°F) 50-90
Placement Location: Shear Wall#6
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Northeast corner of Shear Wall#6 321 32127127 11:05 12:34 7 1/4 4.5 73 142.0 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32127127 Lab ID 1346
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 79680 99440 102500
Compressive Strength(psi) 6340 7910 8160
Test Date 10/07/08 10/28/08 10/28/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
203 October 9, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 10/02/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: B&B Excavating#37542350 Slump Range(in.) 3-8
Total Cubic Yards Placed: 7 1/2 Air Range(%) 4.5-7.5%
Weather/Temperature Partly Cloudy/65 Degrees F Temperature(°F) 50-90
Placement Location: Beam of upper Ievel garage-Gridline H-72
Methods Employed: Two yard bucket with a crane
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
Beam of upper level garage-Gridline H-72 0 32127249 2:00 3:35 10 1/2 2.2 67 - -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32127249 Lab ID 1407
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 62200 77150 75820
Compressive Strength(psi) 4950 6140 6030
Test Date 10/09/08 10/30/08 10/30/08
Test Age 7 28 28
Type of Fracture T3 T5 T5
Additional Comments Field Technician Derek Richards
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
204 October 9, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 10/02/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 5000
Concrete Supplier/Mix ID: B&B Excavating#37042550 Slump Range(in.) 3-8
Total Cubic Yards Placed: 81 Air Range(%) 4.5-7.5
Weather/Temperature Clear/60's Temperature(°F) 50-90
Placement Location: Topping slab precast Area#3 upper level garage pour#3
Methods Employed: Pumped
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
28/BEEE.8 6037 32127201 7:06 8:47 71/2 4.8 68 - 10
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 32127201 Lab ID 1408
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 63170 83720 85730
Compressive Strength(psi) 5030 6660 6820
Test Date 10/09/08 10/30/08 10/30/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Nate Fintel
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
205 October 10, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 10/03/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: Lafarge RMXAGV65GF8 Slump Range(in.) 22-28"
Total Cubic Yards Placed: 460 Air Range(%) 4.5-7.5
Weather/Temperature Partly Cloudy/70's Temperature(°F) 50-90
Placement Location: 1 st floor slab on deck pour 3
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
M/47 4780730 85813215 6:46 7:35 30 6.0 61 139.8 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: g5813215 Lab ID 1380
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 73150 113340 112460
Compressive Strength(psi) 5820 9020 8950
Test Date 10/10/08 10/31/08 10/31/08
Test Age 7 28 28
Type of Fracture T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
206 October 10, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 10/03/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: Lafarge RMXAGV65GF8 Slump Range(in.) 22-28"
Total Cubic Yards Placed: 460 Air Range(%) 4.5-7.5
Weather/Temperature Partly Cloudy/70's Temperature(°F) 50-90
Placement Location: 1 st floor slab on deck pour 3
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
M.5/49 4780640 85908359 7:40 8:22 26 5.7 67 140.3 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 85908359 Lab ID 1381
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 71030 84720 87610 85790
Compressive Strength(psi) 5650 6740 6970 6830
Test Date 10/10/08 10/31/08 10/31/08 10/31/08
Test Age 7 28 28 28
Type of Fracture T5 T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
207 October 10, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 10/03/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: Lafarge RMXAGV65GF8 Slump Range(in.) 22-28"
Total Cubic Yards Placed: 460 Air Range(%) 4.5-7.5
Weather/Temperature Partly Cloudy/70's Temperature(°F) 50-90
Placement Location: 1 st floor slab on deck pour 3
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
H-53 4780810 859083638 8:45 9:30 25 4.8 64 140.8 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: g59083638 Lab ID 1382
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 60370 98300 101810 104630
Compressive Strength(psi) 4800 7820 8100 8330
Test Date 10/10/08 10/31/08 10/31/08 10/31/08
Test Age 7 28 28 28
Type of Fracture T6 T5 T6 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
208 October 10, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 10/03/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: Lafarge RMXAGV65GF8 Slump Range(in.) 22-28"
Total Cubic Yards Placed: 460 Air Range(%) 4.5-7.5
Weather/Temperature Partly Cloudy/70's Temperature(°F) 50-90
Placement Location: 1 st floor slab on deck pour 3
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
H-48 4780045 85813238 8:45 10:03 23 6.4 65 139.5 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: g5813238 Lab ID 1383
Cylinder Diameter(in.) 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57
Maximum Load 75940 117300 116380
Compressive Strength(psi) 6040 9330 9260
Test Date 10/10/08 10/31/08 10/31/08
Test Age 7 28 28
Type of Fracture T2 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
209 October 10, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 10/03/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: Lafarge RMXAGV65GF8 Slump Range(in.) 22-28"
Total Cubic Yards Placed: 460 Air Range(%) 4.5-7.5
Weather/Temperature Partly Cloudy/70's Temperature(°F) 50-90
Placement Location: 1 st floor slab on deck pour 3
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
D-59 4780811 85908375 10:25 11:17 28 6.7 70 139.4 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 85908375 Lab ID 1384
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 87300 113210 113800 117760
Compressive Strength(psi) 6950 9010 9060 9370
Test Date 10/10/08 10/31/08 10/31/08 10/31/08
Test Age 7 28 28 28
Type of Fracture T5 T5 T5 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721
C RDU�1In Client:
Job Name RCR Vail LLC
ENGINEERING C�NSULTRNTS RitzCarltonResidences Address:
CONCRETE FIELD PROPERTIES AND 953 South Frontage Road West, Suite 215
COMPRESSIVE STRENGTH TEST RESULTS Job Number Vail, Colorado 81657
08-6502
Report Number Report Date Attn:
210 October 10, 2008 Mr. Cody O'Kelly
On the date specified above, Ground Engineering Consultants, Inc (GROUND) was requested to provide materials testing services for this project on sampled concrete. GROUND
performed testing in general accordance with tne frequencies required and/or as requested by the contractor or onsite representative of the owner.The following information includes
related site observations for the concrete placement and to the best of our knowledge including information from site representatives. As we provide periodic services on most projects
and may not be onsite during the entire concrete placement, the contractor should be consulted for precise details. This report includes the results of the tests we performed and our
observations,however, it is the responsibility of the contractor to pertorm construction and provide materials that meet the project plans and specifications
Placement Date: 10/03/08 Specifications
Concrete Placed By: PCL Required Strength(psi) 6000
Concrete Supplier/Mix ID: Lafarge RMXAGV65GF8 Slump Range(in.) 22-28"
Total Cubic Yards Placed: 460 Air Range(%) 4.5-7.5
Weather/Temperature Partly Cloudy/70's Temperature(°F) 50-90
Placement Location: 1 st floor slab on deck pour 3
Methods Employed: Pump truck
Test Sample Location Truck No. Ticket No. Batch Time Test Time Slump or Air Content Concrete Unit Weight Water Added
Spread(in.) (/o) Temp:°F (pcf) (gallons)
C.5-47 V708 85908380 11:50 12:27 26 6.3 70 139.9 -
Notification of field test results: Jeff with PCL
Compressive Strenqth Results (ASTM C39) Cylinders Cast from ticket: 85908380 Lab ID 1385
Cylinder Diameter(in.) 4.00 4.00 4.00 4.00
Cross Secional Area(sq in.) 12.57 12.57 12.57 12.57
Maximum Load 86770 128380 122360 124560
Compressive Strength(psi) 6900 10220 9740 9910
Test Date 10/10/08 10/31/08 10/31/08 10/31/08
Test Age 7 28 28 28
Type of Fracture T5 T5 T2 T5
Additional Comments Field Technician Kevin McClure
Corporate Office Gypsum Office
41 Inverness Dr East P.O Box 464
Englewood,CO 80112 Gypsum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Offices:Denver,Loveland,Western Slope,Granby Fax:(970)524 0721