HomeMy WebLinkAboutDeck FP �r�ou�n
ENGINEERING CONSULTRNTS
FIREPROOFING DATA SHEET
Project: Ritz Carlton Residences Date: September 14, 2009
Job Number: 08 6502
Reported to: RCR Vail, LLC Copies to:
953 South Frontage Road West, Suite 215
Vail, Colorado 81657
Attn: Mr. Cody O'Kelly
Decking Test number: 1
THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION
Location: Roof, Gridlines LLL-62.5 Location: Roof, Gridlines LLL-62.5
L � 4 '
Q �� d
� ° � ° ° ThiCkness #1 inches
a �� a
� i� a ThiCkness #2 inches
° � �CREST� ° a Thickness #3 inches
� � � � ThiCkness #4 inches
SIDE SIDE ThiCkness #5 inches
VALLEY
ThiCkness #6 inches
TAI�4 MEASUREJV��fTS Thickness #7 inches
INA1-FOOTSQUAREAREA Thickness #8 inches
ON EACH OF THE FO�LO\MNG: Thickness #9 inches
Thickness #10 inches
Crest Valley Sides Thickness #11 inches
Test Number: Test Number: Test Number: Thickness #12 inches
1.) 13/16 1.) 12/16 1.) 12/16 Volume of test area: cubic feet
2.) 14/16 2.) 12/16 2.) 13/16 Length of test area: inches
3.) 12/16 3.) 14/16 3.) 14/16 Width of test area: inches
4.) 14/16 4.) 13/16 4.) 13/16 Average thickness: inches
DENSITY DETERMINATION
Weight of pan (g)
Weight of pan and material (g)
Weight of material (Ibs) 23.2
Average Thickness (inches) 13/16 Density (pcf) 25.0
Specified Thickness (inches) min. 12/16 Specified density (pcf) min.
ADHESION DETERMINATION Diameter of specimen: 3.25 inches
Location: Area of specimen: 0.0576 sq.ft.
Recorded force: 28 Ibs.
Adhesion (psf) 486 Specified adhesion (psf) min. 150
Notes:
Field Representative: Kevin McClure
�r�ou�n
ENGINEERING CONSULTRNTS
FIREPROOFING DATA SHEET
Project: Ritz Carlton Residences Date: September 25, 2009
Job Number: 08 6502
Reported to: RCR Vail, LLC Copies to:
953 South Frontage Road West, Suite 215
Vail, Colorado 81657
Attn: Mr. Cody O'Kelly
Decking Test number: 2
THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION
Location: Roof, Gridlines G.5/69 Location: Roof, Gridlines G.5/69
�i Q 4 �.
Q �� d
� ° � ° ° ThiCkness #1 inches
a �� a
� i� a ThiCkness #2 inches
° � �CREST� ° a Thickness #3 inches
� � � � ThiCkness #4 inches
SIDE SIDE ThiCkness #5 inches
VALLEY
ThiCkness #6 inches
TAI�4 MEASUREJV��fTS Thickness #7 inches
INA1-FOOTSQUAREAREA Thickness #8 inches
ON EACH OF THE FO�LO\MNG: Thickness #9 inches
Thickness #10 inches
Crest Valley Sides Thickness #11 inches
Test Number: Test Number: Test Number: Thickness #12 inches
1.) 14/16 1.) 13/16 1.) 15/16 Volume of test area: cubic feet
2.) 12/16 2.) 13/16 2.) 12/16 Length of test area: inches
3.) 12/16 3.) 12/16 3.) 13/16 Width of test area: inches
4.) 12/16 4.) 14/16 4.) 13/16 Average thickness: inches
DENSITY DETERMINATION
Weight of pan (g)
Weight of pan and material (g)
Weight of material (Ibs) 0.0000
Average Thickness (inches) 13/16 Density (pc�
Specified Thickness (inches) min. 12/16 Specified density (pcf) min.
ADHESION DETERMINATION Diameter of specimen: inches
Location: Area of specimen: 0 sq.ft.
Recorded force: Ibs.
Adhesion (psf� Specified adhesion (psf� min.
Notes:
Field Representative: Kevin McClure
�r�ou�n
ENGINEERING CONSULTRNTS
FIREPROOFING DATA SHEET
Project: Ritz Carlton Residences Date: November 16, 2009
Job Number: 08 6502
Reported to: RCR Vail, LLC Copies to:
953 South Frontage Road West, Suite 215
Vail, Colorado 81657
Attn: Mr. Cody O'Kelly
Decking Test number: 3
THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION
Location: Roof, Gridlines PPP.2/16.5 Location: Roof, Gridlines PPP.2/16.5
�i Q 4 �.
Q �� d
� ° � ° ° ThiCkness #1 inches
a �� a
� i� a ThiCkness #2 inches
° � �CREST� ° a Thickness #3 inches
� � � � ThiCkness #4 inches
SIDE SIDE ThiCkness #5 inches
VALLEY
ThiCkness #6 inches
TAI�4 MEASUREJV��fTS Thickness #7 inches
INA1-FOOTSQUAREAREA Thickness #8 inches
ON EACH OF THE FO�LO\MNG: Thickness #9 inches
Thickness #10 inches
Crest Valley Sides Thickness #11 inches
Test Number: Test Number: Test Number: Thickness #12 inches
1.) 15/16 1.) 12/16 1.) 12/16 Volume of test area: cubic feet
2.) 14/16 2.) 13/16 2.) 13/16 Length of test area: inches
3.) 14/16 3.) 12/16 3.) 15/16 Width of test area: inches
4.) 12/16 4.) 12/16 4.) 14/16 Average thickness: inches
DENSITY DETERMINATION
Weight of pan (g)
Weight of pan and material (g)
Weight of material (Ibs) 0.0000
Average Thickness (inches) 13/16 Density (pc�
Specified Thickness (inches) min. 12/16 Specified density (pcf) min.
ADHESION DETERMINATION Diameter of specimen: inches
Location: Area of specimen: sq.ft.
Recorded force: /bs.
Adhesion (psf� Specified adhesion (psf� min.
Notes: Adhesion test was performed on 11/17/2009
Field Representative: Kevin McClure
�r�ou�n
ENGINEERING CONSULTRNTS
FIREPROOFING DATA SHEET
Project: Ritz Carlton Residences Date: December 3, 2009
Job Number: 08 6502
Reported to: RCR Vail, LLC Copies to:
953 South Frontage Road West, Suite 215
Vail, Colorado 81657
Attn: Mr. Cody O'Kelly
Decking Test number: 4
THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION
Location: Roof, Gridlines D.0/28.0 Location: Roof, Gridlines D.0/28.0
�i Q 4 �.
Q �� d
� ° � ° ° ThiCkness #1 inches
a �� a
� i� a ThiCkness #2 inches
° � �CREST� ° a Thickness #3 inches
� � � � ThiCkness #4 inches
SIDE SIDE ThiCkness #5 inches
VALLEY
ThiCkness #6 inches
TAI�4 MEASUREJV��fTS Thickness #7 inches
INA1-FOOTSQUAREAREA Thickness #8 inches
ON EACH OF THE FO�LO\MNG: Thickness #9 inches
Thickness #10 inches
Crest Valley Sides Thickness #11 inches
Test Number: Test Number: Test Number: Thickness #12 inches
1.) 12/16 1.) 12/16 1.) 13/16 Volume of test area: cubic feet
2.) 15/16 2.) 12/16 2.) 12/16 Length of test area: inches
3.) 14/16 3.) 12/16 3.) 14/16 Width of test area: inches
4.) 14/16 4.) 13/16 4.) 13/16 Average thickness: inches
DENSITY DETERMINATION
Weight of pan (g)
Weight of pan and material (g)
Weight of material (Ibs) 0.0000
Average Thickness (inches) 13/16 Density (pc�
Specified Thickness (inches) min. 12/16 Specified density (pcf) min.
ADHESION DETERMINATION Diameter of specimen: 3.25 inches
Location: Area of specimen: 0.0576 sq.ft.
Recorded force: 26 Ibs.
Adhesion (psf) 452 Specified adhesion (psf) min. 150
Notes:
Field Representative: Kevin McClure
�r�ou�n
ENGINEERING CONSULTRNTS
FIREPROOFING DATA SHEET
Project: Ritz Carlton Residences Date: January 11, 2010
Job Number: 08 6502
Reported to: RCR Vail, LLC Copies to:
953 South Frontage Road West, Suite 215
Vail, Colorado 81657
Attn: Mr. Cody O'Kelly
Decking Test number: 5
THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION
Location: Roof, Gridlines AA.O/12.2 Location:
�i Q 4 �.
Q �� d
� ° � ° ° ThiCkness #1 inches
a �� a
� i� a ThiCkness #2 inches
° � �CREST� ° a Thickness #3 inches
� � � � ThiCkness #4 inches
SIDE SIDE ThiCkness #5 inches
VALLEY
ThiCkness #6 inches
TAI�4 MEASUREJV��fTS Thickness #7 inches
INA1-FOOTSQUAREAREA Thickness #8 inches
ON EACH OF THE FO�LO\MNG: Thickness #9 inches
Thickness #10 inches
Crest Valley Sides Thickness #11 inches
Test Number: Test Number: Test Number: Thickness #12 inches
1.) 13/16 1.) 12/16 1.) 13/16 Volume of test area: cubic feet
2.) 12/16 2.) 13/16 2.) 15/16 Length of test area: inches
3.) 12/16 3.) 12/16 3.) 12/16 Width of test area: inches
4.) 13/16 4.) 14/16 4.) 12/16 Average thickness: inches
DENSITY DETERMINATION
Weight of pan (g)
Weight of pan and material (g)
Weight of material (g) 17.9
Average Thickness (inches) 13/16 Density (pcf) 24.0
Specified Thickness (inches) min. 12/16 Specified density (pcf) min.
ADHESION DETERMINATION Diameter of specimen: 3.25 inches
Location: Area of specimen: 0.0576 sq.ft.
Recorded force: 25 Ibs.
Adhesion (psf) 434 Specified adhesion (psf) mi 150
Notes:
Field Representative: Kevin McClure
�r�ou�n
ENGINEERING CONSULTRNTS
FIREPROOFING DATA SHEET
Project: Ritz Carlton Residences Date: January 11, 2010
Job Number: 08 6502
Reported to: RCR Vail, LLC Copies to:
953 South Frontage Road West, Suite 215
Vail, Colorado 81657
Attn: Mr. Cody O'Kelly
Decking Test number: 6
THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION
Location: Level 6, G.0/23.0 Location: 0
�i Q 4 �.
4 �Q d
� ° � ° ° ThiCkness #1 inches
a �� a
� i� a ThiCkness #2 inches
° � �CREST� ° a Thickness #3 inches
� � � � ThiCkness #4 inches
SIDE SIDE ThiCkness #5 inches
VALLEY
ThiCkness #6 inches
TAI�4 MEASUREJV��fTS Thickness #7 inches
INA1-FOOTSQUAREAREA Thickness #8 inches
ON EACH OF THE FO�LO\MNG: Thickness #9 inches
Thickness #10 inches
Crest Valley Sides Thickness #11 inches
Test Number: Test Number: Test Number: Thickness #12 inches
1.) 14/16 1.) 13/16 1.) 13/16 Volume of test area: cubic feet
2.) 14/16 2.) 14/16 2.) 14/16 Length of test area: inches
3.) 14/16 3.) 12/16 3.) 13/16 Width of test area: inches
4.) 14/16 4.) 12/16 4.) 13/16 Average thickness: inches
DENSITY DETERMINATION
Weight of pan (g)
Weight of pan and material (g)
Weight of material (Ibs)
Average Thickness (inches) 13/16 Density (pc�
Specified Thickness (inches) min. 12/16 Specified density (pcf) min.
ADHESION DETERMINATION Diameter of specimen: inches
Location: Area of specimen: 0 sq.ft.
Recorded force: Ibs.
Adhesion (psf) Specified adhesion (psf) min.
Notes:
Field Representative: Kevin McClure