HomeMy WebLinkAboutOD100311-Shop Discrepancies Page 1 of 3
CRDUIIIn
ENGINEERING CDNSULTRNTS
List of Outstanding Discrepancies
Project Name: Ritz Carlton Residences (Shop List)
Project No: 08-6502
Client: Vail Resort Development Company Date: 3/11/2010
Address: 953 S. Frontage Rd., West, Suite 215
Vail, CO 81657
Attn: Mr. Cody O'Kelly
It is the responsibility of the contractor to notify GROUND once corrections have been made and to schedule re-
observations. The contractor should provide our office hard copies of any changes or approvals made by the
Structural Engineer of Record.
Date Item Outstanding Discrepancy Date Per Plan/
Re orted No. Acce ted Per RFI
02-19-08 1 13 - 4248-A embed plates had undercut. They were 03-05-08 Per Plan
marked with orange paint.
03-10-09 2 Part#52AL-569 was found in non-compliance due to 03-16-09 Per Plan
a missing weld.
03-10-09 3 Part#52A-618 was in non-compliance due to 3-20-09 Per Plan
undercut.
03-10-09 4 Part#52A-565 was in non-compliance due to 3-20-09 Per Plan
undercut.
03-16-09 5 Part#52-A-834 was in non-compliance due to a 4-7-09 Per Plan
missing weld.
03-16-09 6 Part#52-AL-906 was in non-compliance due to a 3-20-09 3-20-09
missing weld.
03-24-09 7 Part#52-AL-536 was in non-compliance due to 04-21-09 Per Plan
missing welds.
03-24-09 8 Part#52-AL-851 was in non-compliance due to 04-21-09 Per Plan
missing welds.
Corporate Office Gypsum Office
41 Inverness Drive East PO Box 464
Englewood,CO 80112 Gypum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Fax:(970)524 0721
Page 2 of 3
Date Item Outstanding Discrepancy Date Per Plan/
Re orted No. Acce ted Per RFI
03-24-09 9 Part#52-AL-486 was in non-compliance due to 04-20-09 Per Plan
missing welds.
03-24-09 10 Part#52-AL-812 was in non-compliance due to 04-20-09 Per Plan
missing welds.
3-24-09 11 Part#52-AL-845 was in non-compliance due to torch 4-7-09 Per Plan
gouges on the weld access holes.
04-07-09 12 Part#52-AL-349 was in non-compliance due to 04-23-09 Per Plan
undercut.
04-22-09 13 Assembly#52AL774, missing weld on clip angle to 04-23-09 Per Plan
flange and gouges in access hole for flange CJP.
04-22-09 14 Assembly#52AL732, 3/16" fillet welds on angle 04-23-09 Per Plan
kickers not full length.
04-22-09 15 Assembly#52AL731, 3/16" fillet welds on angle 04-23-09 Per Plan
kickers not full length.
04-22-09 16 Assembly#52AL557, 3/16" fillet welds on angle 04-23-09 Per Plan
kickers not full length.
04-22-09 17 Assembly#52AL674, 3/16" fillet welds on angle 04-23-09 Per Plan
kickers not full length.
04-22-09 18 Assembly#52AL895, under filled CJP weld on two 04-23-09 Per Plan
shear plates.
04-22-09 19 Assembly#52AL429, 3/16" fillet welds on angle 04-05-09 Per Plan
kickers not full length.
04-22-09 20 Assembly#52AL425, 5/16" fillet weld not full length 05-05-09 Per Plan
on 3 sides of bent plate (connection plate).
04-22-09 21 Assembly#52A552, under filled PJP weld on shear 04-28-09 Per Plan
plate.
04-22-09 22 Assembly#52AL340, weld spacing on top flange bent 04-28-09 Per Plan
plate not 3" - 24" at one location both sides.
Corporate Office Gypsum Office
41 Inverness Drive East PO Box 464
Englewood,CO 80112 Gypum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Fax:(970)524 0721
Page 3 of 3
Date Item Outstanding Discrepancy Date Per Plan/
Re orted No. Acce ted Per RFI
03-10-09 63 Part number 52AL-569 non compliant due to missing 3-16-09 Per Plan
welds. Moved from field list on 12/17/09
03-10-09 64 Part number 52A618 non compliant due to slag 3-20-09 Per Plan
inclusions. Moved from field list on 12/17/09
03-10-09 65 Part number 52A565 non compliant due to undercut. 3-20-09 Per Plan
Moved from field list on 12/17/09
Corporate Office Gypsum Office
41 Inverness Drive East PO Box 464
Englewood,CO 80112 Gypum CO 81637
Tel:(303)289 1989 Tel:(970)524 0720
Fax:(303)289 1686 Fax:(970)524 0721