Loading...
HomeMy WebLinkAboutOD100311-Shop Discrepancies Page 1 of 3 CRDUIIIn ENGINEERING CDNSULTRNTS List of Outstanding Discrepancies Project Name: Ritz Carlton Residences (Shop List) Project No: 08-6502 Client: Vail Resort Development Company Date: 3/11/2010 Address: 953 S. Frontage Rd., West, Suite 215 Vail, CO 81657 Attn: Mr. Cody O'Kelly It is the responsibility of the contractor to notify GROUND once corrections have been made and to schedule re- observations. The contractor should provide our office hard copies of any changes or approvals made by the Structural Engineer of Record. Date Item Outstanding Discrepancy Date Per Plan/ Re orted No. Acce ted Per RFI 02-19-08 1 13 - 4248-A embed plates had undercut. They were 03-05-08 Per Plan marked with orange paint. 03-10-09 2 Part#52AL-569 was found in non-compliance due to 03-16-09 Per Plan a missing weld. 03-10-09 3 Part#52A-618 was in non-compliance due to 3-20-09 Per Plan undercut. 03-10-09 4 Part#52A-565 was in non-compliance due to 3-20-09 Per Plan undercut. 03-16-09 5 Part#52-A-834 was in non-compliance due to a 4-7-09 Per Plan missing weld. 03-16-09 6 Part#52-AL-906 was in non-compliance due to a 3-20-09 3-20-09 missing weld. 03-24-09 7 Part#52-AL-536 was in non-compliance due to 04-21-09 Per Plan missing welds. 03-24-09 8 Part#52-AL-851 was in non-compliance due to 04-21-09 Per Plan missing welds. Corporate Office Gypsum Office 41 Inverness Drive East PO Box 464 Englewood,CO 80112 Gypum CO 81637 Tel:(303)289 1989 Tel:(970)524 0720 Fax:(303)289 1686 Fax:(970)524 0721 Page 2 of 3 Date Item Outstanding Discrepancy Date Per Plan/ Re orted No. Acce ted Per RFI 03-24-09 9 Part#52-AL-486 was in non-compliance due to 04-20-09 Per Plan missing welds. 03-24-09 10 Part#52-AL-812 was in non-compliance due to 04-20-09 Per Plan missing welds. 3-24-09 11 Part#52-AL-845 was in non-compliance due to torch 4-7-09 Per Plan gouges on the weld access holes. 04-07-09 12 Part#52-AL-349 was in non-compliance due to 04-23-09 Per Plan undercut. 04-22-09 13 Assembly#52AL774, missing weld on clip angle to 04-23-09 Per Plan flange and gouges in access hole for flange CJP. 04-22-09 14 Assembly#52AL732, 3/16" fillet welds on angle 04-23-09 Per Plan kickers not full length. 04-22-09 15 Assembly#52AL731, 3/16" fillet welds on angle 04-23-09 Per Plan kickers not full length. 04-22-09 16 Assembly#52AL557, 3/16" fillet welds on angle 04-23-09 Per Plan kickers not full length. 04-22-09 17 Assembly#52AL674, 3/16" fillet welds on angle 04-23-09 Per Plan kickers not full length. 04-22-09 18 Assembly#52AL895, under filled CJP weld on two 04-23-09 Per Plan shear plates. 04-22-09 19 Assembly#52AL429, 3/16" fillet welds on angle 04-05-09 Per Plan kickers not full length. 04-22-09 20 Assembly#52AL425, 5/16" fillet weld not full length 05-05-09 Per Plan on 3 sides of bent plate (connection plate). 04-22-09 21 Assembly#52A552, under filled PJP weld on shear 04-28-09 Per Plan plate. 04-22-09 22 Assembly#52AL340, weld spacing on top flange bent 04-28-09 Per Plan plate not 3" - 24" at one location both sides. Corporate Office Gypsum Office 41 Inverness Drive East PO Box 464 Englewood,CO 80112 Gypum CO 81637 Tel:(303)289 1989 Tel:(970)524 0720 Fax:(303)289 1686 Fax:(970)524 0721 Page 3 of 3 Date Item Outstanding Discrepancy Date Per Plan/ Re orted No. Acce ted Per RFI 03-10-09 63 Part number 52AL-569 non compliant due to missing 3-16-09 Per Plan welds. Moved from field list on 12/17/09 03-10-09 64 Part number 52A618 non compliant due to slag 3-20-09 Per Plan inclusions. Moved from field list on 12/17/09 03-10-09 65 Part number 52A565 non compliant due to undercut. 3-20-09 Per Plan Moved from field list on 12/17/09 Corporate Office Gypsum Office 41 Inverness Drive East PO Box 464 Englewood,CO 80112 Gypum CO 81637 Tel:(303)289 1989 Tel:(970)524 0720 Fax:(303)289 1686 Fax:(970)524 0721