Loading...
HomeMy WebLinkAboutM10-0262NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT MWOFVK Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 4650 MEADOW DR VAIL Location.....: BUILDING 11, UNIT 13 Parcel No...: 210112404013 OWNER THOMAS, JEROME V. & RITA 11/01/2010 8071 SUMMERBREEZE LN BOCA RATON FL 33496 APPLICANT MOUNTAIN MAN FIREPLACE AND C 11/01/2010 Phone: 303 - 679 -1601 7001 HIGHWAY 73 EVERGREEN CO 80439 License: 438 -M CONTRACTOR MOUNTAIN MAN FIREPLACE AND C 11/01/2010 Phone: 303 - 679 -1601 7001 HIGHWAY 73 EVERGREEN CO 80439 License: 438 -M Desciption: INSTALL NEW WOOD BURNING STOVE. Valuation: $1,654.00 ALL TIMES Permit #: M10 -0262 Project #: PRJ10 -0728 Status ...: ISSUED Applied ..: 11/01/2010 Issued . .. 11/09/2010 Expires. .: 05/08/2011 ...+,*..*.... �.* �....>.>...,.» ..............: *.... :... *�..,...... *.... <.. » »* *'*""" SUMMARY*.., t...... �.<... ��, �,..»... ��, �.....,+*,.... �., t.*,....,+*..,`.,.. ... *.. *..............,.... «..., Mechanical Permit Fee --- > $40.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $54.00 Plan Check ------------------- > $10.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00 Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $54.00 Total Calculated Fees - -> $54.00 Payments ----- — ---------- > $54.00 BALANCE DUE --------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 11/01/2010 DRHOADES Action: AP OK TO APPROVE PER JRM CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE, Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. 1 agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSP CTION SHALL BE -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01 AM - 4 PM. �J / /��N /�1 ignature of Own Contractor Date Print Name m e c h ca n i ca I_pe rm it_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R100001806 Amount: $54.00 11/09/201001:32 PM Payment Method: Check Init: SAB Notation: CK# 13254 CHRISTOPHER GUFFEY ----------------------------------------------------------------------------- Permit No: M10 -0262 Type: MECHANICAL PERMIT Parcel No: 2101 - 124 - 0401 -3 Site Address: 4650 MEADOW DR VAIL Location: BUILDING 11, UNIT 13 Total Fees: $54.00 This Payment: $54.00 Total ALL Pmts: $54.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- MP 00100003111100 MECHANICAL PERMIT FEES 40.00 PF 00100003112300 PLAN CHECK FEES 10.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 OCT -29 -2010 07:48 FROM: TO:19704792452 P.3/9 Boller / Furnace & Fireplace Aanllcatlans MUD Include: ❑ Complete Mechanical Room Floor Plan with Dimensions ❑ Boiler size & efficiency in Combustion Air Duct Size and Location Equipment Cut Sheets for Fireplaces /Log Sets a Flue detail or Vent size, location & termination _Manufacturer's Info showin make, model & approva listi o Gas Piping layout including development length calculations Office Use: �.V 10 - 0013 ❑ Heat Loss Calculations Project #: Prt2N 10 " 0fZas Project Street Addres Building Permit #; W + �G �D l � ^ >' T up 6114b DYl yA Mechanical Permit #: o'Q (Number) (Street) (Suite #) /� Lot #: Block # Subdivision: Building/Complex Name: u- 1 +C(; , e+ CLU , L Q o_�'t1..___..__ _.__j Define Scope and Location of Work: Contractor Infor tion: 5 e 7 — r og C N Company; � / i Company Address, 1�N 1 City: State: Zip: L2 � 39 0 (use aaailional sheet it necessary) Contact Name: � A) sp o Gas Piping Included Contact Phone 30 7 9 ' i' �D 0 G n Gas Piping by Others E -Mail � A'KS (�; T& /Z �. L�%Y� p Wood to Gas Firoplaco Convorsion Town of Va' Contractor R gi ation No,: / X ` Boller Location: Interior ( ) Exterior ( ) Other ..... ....... ( ) X ..,.,.,,..,..,..._.,.,..._... .................._�. __..__.. ................ ..... _..... __.... .. ._. Co rector Sign re (required) Number of Existing Fireplaces: Gas Appliances Gas Logs Wood /Pellet _._..._ _ Property Infor atlon �{. Parcel #: --- '_ I f 12 4 'O 1 Number of Proposed Fireplaces: I (For parcel #, contact Eagle County Assessors Office at 970 - 328.8640 or Gas Appliances Gas Logs Wood /Pellet ` visit www.eaglecounty.us /patie) €...._....__��..._..,__,.. ... _.. ...._._.. __......_...._. _.— _ .. ._. € Type of Building: 7enanl Name: ,� A� GLZ �Commerciq ropertias Owner Name: _)eVom0_1 Complete Valuation for Mechanical irrmit: (inclucli p fireplaces) Mechanical $: Ap r 6 5 Single - Family ( ) Duplex ( Restaurant ( ) Other( Date Received: CEL Multi - Family Commercial OCT 2 a 2010 TOWN OF VAIL MECHANICAL PERMIT OCT -29 -2010 07:49 FROM: TO:19704792452 P.4/9 Ua1 1u 1U UVUe Veil Kscguet Ulub - Malnt b /U4( /JUt)1 p.'L account Purge I. of I Account: 8033527 Location Purcel Number 2t01- 1 24 - 04 - 013 Tax Arta SC 103 - VAIL (TOWN) - SC 103 Sltus Address 4450 VAtL RACQUET CLUD DR 013 l,e&i1 SurnmAry DESC,: BLDG 1 I Subdivision: VAIL RACQUET CLUB CONDOWNIUMS Unit: 13 UK -0704 PG -0066 WD 09 -27 -96 R21NJ813668 DC: 08 -16-07 Tr n fer Qw 1iIf OTmati0n Owner Name TMMAS, JEROMEV. & RITA Owner Address 19333 D E 4SB11RY DR AURORA, CO 50013 Snlr Price Cafe nate 3 U (1 1 / 997 S 31,9 00 I I /2b� 194 Images A »95minl Bator Actua1(2010) $332.250 Primary Taxable 526.450 Tax Arco: SC103 Mill Loevy. 44.2270 Type Actual Assessed Acres SQET Improvements 5792,540 $23,290 Lund 539,710 113,160 0.026 576.400 Receptioe Number 1300k. page 8 025_7 P 9.1 s3 B. 0243 P O(r10 liq:,`/ property. cagglccowity .us /assessor /taxwt b/account.j5 ?acccuntNum =R033527 WfM2010 OCT -29 -2010 07:49 FROM: 2100 & 2200 LEG MODELS & PEDESTAL MODELS SAFETY INFORMATION If the Information In them Instructions Is not followed exactly, a flre or explosion may result causing property damage, personal injury or death. Improper Installation, adjustment, alteration, service or maintenance can cause Injury or property damage, bodily injury or even death. Please read entire manual before you install and use your applianco, - This appllenca can bo vary hot when burning. . Combustible materials such as firewood, wet clothing, etc. placed too close can catch fire. -Children and pats must bo kept from touching the appliance when It Is hot. • The chimney must be sound and free of cracks. Before Installing this unit, contact the local building or fire authority and follow their guidelines. • Operate only with the door tightly closed. • Burn wood behind the log retainer directly on the firebricks. • Do not use an elevated grata or otherwise raise the fire. At least 14 equaro Inches of outsldo air must bo admlttod to tho room or directly to the unit through a 4" diameter pipe. - This appliance Is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning alt dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. • Do not start a fire with chemicals or flulde such as gasoline, engine oil, etc, - Do not burn treated wood, coal, charcoal, coloured paper, cardboard, eolvente or garbage. • Do not lot the appliance become hot enough for any part to glow red. . KEEP THE STOVE TOP TEMPERATURE BELOW 700 °E 1371 °C1. Attempts to achieve hest output rates that exceed design specifications can result In stool distortion and damage, TO:19704792452 P.5/9 lorw O VIO) " .......... FU �.L L tlS s4 �i l' �iL ?• �'i xl ii �H CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 40 0,1' R PART 130 AND THE OREGON DEPARTMENT Uh ENVIRONMENTAL QUALITY (O.E Q) PARTICULATE EMISSION STANDARDS BY E.E.M.0 THESE STOVES HAVE BEEN TESTED AND LISTED BY OMNI TESTING SERVICES TO STANDARDS. GSA 8388.2, ULC S027, UL 1482• $10.00 1.14 Vohs V0 I M 7A na OCT -'29 -2010 07:49 FROM: TO:19704792452 P.6/9 6 1.2 DIMENSIONS 2100 W e" s 1u 19 31d" 21 618" 2200 1 22 3 /4" 24 618" 31 13" Ll 6 112" RJ 6" 1.3 SPECIFICATIONS Specifications 2100 2200 WIDTH 26" 26" DEPTH 21 5/8" 24 5/8" FLUE CENTER LINE TO REAR 61/2 6 1/2" FLUE CENTER LINE TO SIDE 13" 13" HEIGHT PEDESTAL MODEL 29 7/8" 29 7/8" HEIGHT LEG MODEL 315/8' 31 5/8" CHAMBER (D.W.H) 11 5/8 x 20 7/8 x 11 5/8 14 5/8 x 20 7/8 x 11 5/8 CAPACITY 1.5 cubic feet 1.9 cubic feet APPROX. AREA HEATED' 600 -1800 square feet 800 -1800 square feet HEAT OUTPUT (HIGH BURN) — 45,000 BTU 60, 000 BTU DURATION LOW FIRE' 6 hours 8 hours WEIGHT w/o BRICKS 180 Ibs 210 Ibs WEIGHT OF BRICKS 47 lb 60 Ibs Figures will vary considerably with individual conditions. 11 Wolf Steel Ltd. estimated realistic BTU /h with hardwood logs and regular refueling. OCT -�?9 -2010 07:50 FROM: 70:19704792452 P.7/9 10 2.1 CLEARANCE TO COMBUSTIBLES DO NOT INSTALL INTO ANY AREA HAVING LESS THAN 7 FEET (CEILING TO APPLIANCE BOTTOM, EXCLUDING HEARTH HEIGHT). BACK WALL BACK WALL J J W D N PARALLEL & CORNER SINGLL WALL CONNECTOR DOUBLE WALL CONNECTOR SIDEWALL (A) 19" 19, SIDEWALL TO FLUE (B) 28 718" 28 7/8" BACKWALL (C) 17 1/2" 12 1/2" BACKWALL TO FLUE (D) 21" 16 " CORNER (E) 11 " 7 ALC PARALLEL & CORNER • •- DOUBLE WALL CONNECTOR BACKWALL (F) 12 1/2 12 1/2" CEILING (G) 42" 42" CEILING (H) 72 11 72" j= Minimum width 52 11 , Minimum depth 32" FL OOR MINIMUM PROTECTIO K •• ■ CANADA 18" 8" 8" O J USA 16" 8" 8" bjQjf; If a section of horizontal chimney connector Is used, floor protection Is I required under the chimney connector and 2" beyond each side, You may decrease the minimum clearances to combustible materials by installing heat radiation shields be- tween the walls or the ceiling and the appliance. Those heat radiation shields must be installed permanently. These reduced clearances must be approved by a regulatory authority. 2.2 FLOOR PROTECTION If the appliance Is to be installed on top of a combustible floor, it must be guarded by a non - combustible mate- rial extending a minimum 18" (16" in the United States) from the front and 8" from the sides and back of the appliance, see "CLEARANCE TO COMBUSTIBLES" section. NOTE: Floor protection is required for spark and ash shielding, but not for limiting floor temperatures from the radiant heat of the appliance. The appliance was designed and safety tested so that without any protection, the floor would not overheat. Refer to local building codes for suitable floor protection materials. OCT -29 -2010 07:50 FROM: TO:19704792452 P.8/9 15 2.3.4 TYPICAL THROUGH THE WALL If possible, design the installation so that the connector does not pass through a combustible wall. If during your installation you must pass through a combustible wall, check with your building inspector before you be- gin. Also check with the chimney connector manufacturer for any specific requirements. Consult with your dealer regarding special connection components available for use for wall pass - throughs. Use only parts that have been tested and listed for use in a wall pass - through. FLOOR � Ff COMBUSTIBLE PROTECTOR WALL 61.1 ERMINAL MAINTAIN 2" ROOF CLEARANCE THROUGH EAVE COMBUSTIBLE STORM OUTSIDE WALL COLLAR SECTION LISTED FLASHING LISTED CHIMNEY 2 CHIMNEY PIPE CLEARANCE TO I INSULATED TOVE COMBUSTIBLE „ CEILING WALL SUPPORT THIMBLE WALL SPACER FOR OUTSIDE WALL CHIMNEY CONNECTION CONNECTOR DETAIL FLOOR � Ff COMBUSTIBLE PROTECTOR WALL 61.1 OCT -29 -2010 07:50 FROM: TO:19704792452 P.9/9 DuraVent Page 1 of 2 login f, 0dealer locator all -fuel I pellet I relining direct vent I stovepipe I gas featuresi New interactive installation guide All l k w trE Ventinox J Fds%eal DVL® DVL's double -wall, air-insulated design reduces clearances to combustibles from 18" to 6" the closest clearance to a wall of any connector pipe. DVL improves stove performance by maintaining high flue gas temperatures for a strong, steady draft. Because the inner wall is stainless steel the flue heats up faster, stays hot longer, minimizes the formation of creosote, and has the same life expectartLy as the chimney. Adjustable lengths eliminate the need for cutting or crimping. Required for Manufactured Horne installations, See appliance manufacturer's installation instructions. Applications Double -wall interior stovepipe for connecting woodstoves to manufactured chimney_ Materials and Construction .016" stainiess steel inner wall. .018'gaivanized outer, painted black. Clearances 6" clearance to walls. 8" clearance to ceilings, including cathedral cellings. Diameters 6' 1 and 8 ". Listings c -UL -us listed to ULC S641 (MH14089). Limited Lifetime Warranty 46 catalogs and instructions I sdv news I durapro I login I technical support I about us I contact us I home 02010M&s0uuraVent,Inr AI nghtdraserved catalog I installation instructions I FAQ's