Loading...
HomeMy WebLinkAboutM10-0272NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT MWNO VVAp, Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 5040 MAIN GORE PL VAIL Location.....: SUNDIAL UNIT A -1 Parcel No...: 210113105007 OWNER LANGEREIS, ARTHUR HENRY 5040 MAIN GORE PL Al VAIL CO 81657 APPLICANT JERRY SIBLEY PLUMBING P.O. BOX 340 MINTURN CO 81645 License: 152 -M CONTRACTOR JERRY SIBLEY PLUMBING P.O. BOX 340 MINTURN CO 81645 License: 152 -M 11/10/2010 11/10/2010 Phone: 970-827-5736 11/10/2010 Phone: 970-827-5736 Desciption: FURNACE REPLACEMENT, INSTALL NEW SEALED COMBUSTION FLUE: 75,000 BTU 95% Valuation: $4,300.00 ALL TIMES Permit #: M10 -0272 Project #: PRJ10 -0744 Status ...: ISSUED Applied..: 11/10/2010 Issued . .: 11/17/2010 Expires. .: 05/16/2011 Total Calculated Fees - -> $129.00 Payments - - -- - - -> $129.00 BALANCE DUE - - -> $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 11/13/2010 Martin Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 +++++++++++++++++++++++++++«+ w+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ w+++++++++++++++++►++++++ ne+ fnt + + + +++++ww++ +w + +++ + + + +++ +m+«+ ++ DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR I HNADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01 AM - 4 PM. 1111 ignature of r or Contractor Date Name mechcanica I_perm it_041908 «« « ««« « « « +««« + FEE SUMMARY­*­**"**** +«++++++++++++«««++.«««+«««««««+« +++++. +..+«... «««« « « ++. «...««.+ Mechanical Permit Fee —> $100.00 Will Call - - - -> $4.00 Total Calculated Fees - -> $129.00 Plan Check---- - - - - -> $25.00 Use Tax Fee ------ > $0.00 Additional Fees- - - - - -> $0.00 Investigation--- - - - - -> $0.00 TOTAL PERMIT FEE--> $129.00 Total Calculated Fees - -> $129.00 Payments - - -- - - -> $129.00 BALANCE DUE - - -> $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 11/13/2010 Martin Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 +++++++++++++++++++++++++++«+ w+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ w+++++++++++++++++►++++++ ne+ fnt + + + +++++ww++ +w + +++ + + + +++ +m+«+ ++ DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR I HNADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01 AM - 4 PM. 1111 ignature of r or Contractor Date Name mechcanica I_perm it_041908 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001856 Amount: $129.00 11/17/201010:50 AM Payment Method: Check Init: SAB Notation: 32074 JERRY SIBLEY ----------------------------------------------------------------------------- Permit No: M10 -0272 Type: MECHANICAL PERMIT Parcel No: 2101 - 131 - 0500 -7 Site Address: 5040 MAIN GORE PL VAIL Location: SUNDIAL UNIT A -1 Total Fees: $129.00 This Payment: $129.00 Total ALL Pmts: $129.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- MP 00100003111100 MECHANICAL PERMIT FEES 100.00 PF 00100003112300 PLAN CHECK FEES 25.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 NOV- 05- 2010(FRI) 04:08 V"Complete Mechanical Ro wl" Combustion Air Duct Size and Location ta detail or Vent size, location & termination • Gas Piping layout Including development length calculations • Heat Loss Calculations Protect Street Address: 640 Mace— N 1% 1 1-4tall d1 -07 50 .�D� Y' Equipment Cut Sheets for Fireplaces/Log Sets (Manufacturer's Info showing make, model & appn P. 001 /006 Office Use: Project #: '� � l - 0A a"'1 Building Permit #: — /IA ' Mechanical Permit V U) - 6 Z ( um er) ( Street 1 Lot V. Block # Building /Complex Name: CLA I Nam Defte Sc and Location of Work: � �[.wy� A De _ Contractor Information Company: J 'S `6 1 +tPr• ! Company Address: l ogo ► P Y City 1� &!W..� State: j // Zip: SIG LK Contact Name: Contact Phone: Town of Vail Contractor Registration No.: Signature Property infonnatlon Parcel *. 7-161 - -- A 31— 1 05 — 00 q (For parcel #, contact Eagle Counry Assessors Office at 970-32&490 or visit www.eagleccunty.uslpatle) Tenant Name: (Commercial Properties) Owner Name. G �+. l�1d3�C mff� C� omplete Valuation for Mechanical Permit: (including fireplaces) Mechanical C:\ edcv\ forms\permits \building\ineehanicW_pc mil olo►to Subdivision: M ri M a NU Gas Piping Included Gas Piping by Others Wood to Gas Fireplace Conversion Interior (✓f Exterior ( ) Other ( ) Fireplaces: Gas Appliances � as Logs Wood/Pellet Number reposed Fireplaces: Gas Appliances Gas Logs Wood /Pellet Typo of Building: Single- Family ( ) Duplex (Multi- Family ( ) Commercial ( ) Restaurant( ) Other ( ) Date Received: NOV 0 5 2010 TOWN OF VAIL MECHANICAL PERMIT Boiler / Furnace & Fireplace Applications MUST indude: ' rwrL� om Floor Plan with Dimensions o 9ellerslze & efficiency NOV- 05- 2010(FRI) OQ;08 � ►' �-r�' i:� g&5 k Q�1 1ir FU eve +5L� d'e- [A),-,L d Ctf PQ-� Town of Vail "L D REVIEWED FOR CODE COMPLI NCE / 1 13 i v at BY o J ca Code: P. 0021006 pX 513 NOV- 05- 2010(FRI) Od:08 P. 003/006 FORM NO. G11 -503 1 , al �-t �.� 26- 01 CMA-� VW W0WjVNWM=M RGRC- SERIES Model with Input Rates from 45,000 to 105,000'BTU /HR [13.19 to 30.77 kW] (All Models 95 %A.F.U.E.t) d ,A ¢� member G gama CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES The Rheem° 95%A.F.U.E. High Efficiency line of upflow gas furnaces are designed for utility moms, closets or alcoves. The design Is certified by CSA. Features ■ Heat exchanger is constructed of all stainless steel for maximum corrosion resistance and thermal fatigue roliablllty. le Low profile "34 Inch` design Is lighter and easier to han- dle and leaves room for optional accessories. • Left or right side gas, electric, and condensate drainage connections on upflow models. • Integrated control board manages all operational func- tions and provides hookups for humidifier and electronic air cleaner. • An Insulated blower compartment, a slow - opening gas valve and a specially designed Inducer system make it one of the quietest furnaces on the market today. • Pre -paint galvanized steel cabinet. • Molded permanent filters. r Optional Indoor or outdoor combustion air. In addition, combustion air may be piped to either the top or side of the cabinet on all upflow models. A special molded fitting Is provided to ease Installation. ■ Control fuse protection. • Solid bottom Is standard. • Control board diagnostics. A variety of cooling coils and plenums designed to use with the Classic 95% A.F.U.E. gas furnaces are available as optional accessories for air conditioning models. TA.F.UZ VLNWW fool IJIWA un EffWl alculeled In amroNena wlft DuVal of error ru owl NOV- 05- 2010(FRI) Oa;08 STANDARD EQUIPMENT Complomly assembled and wired; heat exchanger. primary: 409 and aluminlmd 409 stainless stool, secondary: 29.40 stainless steel; induced draft; pressure switches: redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut -off Valve; 100% safety lock out; cool tan off delay; held selectable heat tan oil dolay; one hour automatic retry; power and sell -test diagnostics; llama sense current diagnostics; electronic air cleaner connections; twinning (bunt -In) foaturos; humidifier connections; humidifier onlof delay; low speed continuous fan option; single speed option for heating and cooling applications; pressure regulator for natural and L.P. (propono) gasses; transformer; direct drive, muitl- speed blower motor. (Please note: a thermostat Is not Included as standard equipment.) P. OOd /006 OPTIONAL EQUIPMENT Side and bottom tiller racks; return air cabinet for all atzos. NOTE: Furnace Is not hated for use with fuels other than natural or LP. (propane) gas. All models can be converted by a qualified distributor or local service dealer to use LP. (propane) gas without changing burners. Factory approved Idts must be used to convert from natural to LP. (propane) gas and may be ordered as optional accessorles from a parts distributor. For LP. (propane) oporallon, refer to Conversion Kit Index Form. Rheem Heating, Cooling and Water Healing NOV- 05- 2010(FRI) 0r1:09 P. 0051006 BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. MEEMEE PHYSICAL DATA AND SPECIFICATION -U PF ` W MODELS 11 C 2nd f!nnadion Mndole MODEL NUMBERS RGRC44'MAES RGRC-OB'MAES L RGRC- 07 -MAES RGRC -07 9 RIGS RGRC-OB'ZAiS RGRC- 10'I1W8 HIGH FIRE INPUT BTU/HR WM W 45,000 [13.191 60.000117M] 1 75.000 [21.98] 90,000 (26.38) 106.000 130.771 HEATING CAPACITY BTUMR (k1N] 42,000 [12.31] 56,000 [16.41] 70,000 [20.51] 70,000 [20.51] 84,000•[24.621 100,000 [29271 HIGH ALTITUDE OUTPUT AT 8000' 28,458 [8.341 37,944 [11.121 47,430 (13.901 47,430 113.901 56,915 116.691 66,402 [19A6] (HIGH FIRE) [kWJ d9 BLOWER (DxW) [mm] 110 1279 x 1781 110 1279 x 1781 11 x7 1279 x 1781 12x11 1305 x 2791 12x11 [305 x 2701 12x11 [305 x 2791 MOTOR H.P. [W] t/z [3731 - 4 - PSC 1 12 [373] - 4 - PSC 1/2 [373] - 4 - PSC 1/2 [373] - PSC e14 [559] - PSC 3 /4 [559]4 - PSC TYPE MOTOR FULL LOAD AMPS GA 6.8 6.8 6.8 9.5 9.5 HEATING SPEED MED -LO MED -HIGH MED -HIGH MED -HIGH MED -HIGH • MED -HIGH COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH MINIMUM Eff. STATIC PRESSURE 10 [.0251 .12 [.029] .12 [.029] .12 [.029] .15 [.0371 20 [.0491 (IN. W.C.) [kPa1 MAXIMUM EXT. STA11C PRESSURE .50 [.1241 .50 [.124[ .50 [.1241 . .50 [.124) .50 [.1241 .50 [.1241 (IN. W.C.) [kPa] HEATING CFM 01' 1.049 kPaJ 88514171 84513961 1050 [4951 1500 [7061 1640 [7741 1445 [6621 W.C. E.S.P. [Us] COOLING CFM M .5' 1.124 kPa] 119515641 1100 [519] 1110 [524] 1600 [755] 1820 [8591 1810 [854] W.C. F [US] TEMPERATURE RISE -HIGH FIRE RANGE IN DEGREES - F ['C[ 30.60 [16.7 -33.3] 40.70 [222 - 38.91 40.70 [222 -38.91 30.60 [16.7 -33.31 35.65 [19.4 -36.11 50.60 [27.844.4] RETURN AIR CABINETS (OPT.) C178 C170 C178 C218 C218 C218 RXGR- FILTER SIZE (2) 17 x 16' [305 x 4061 (2)12' x 16 [305 x 4061 (2)12' x 16' [305 x 4061 (2)12' x 20' 1305 x 5081 (2)12' x 20 1305 x 5061 (2) 17 x 20" 1305 x 5081 ImmJ STANDARD, HIGH VELOCITY 15 x 25 x 1 153/4 x 25 x 1 15314 x 25 x 1 19 1 /4 x 25'x 1 19 x•25 x 1 191/4 x 25 x 1 PERMANENT FILTER (IN.) APPROX. SHIPPING WEIGHT 111 [503] 117 [53.1] 124 [56.2] 137 [62.1 148 [67.11 152 [68.9] (LBS.) f k01 AFUE W 95,096 95.096 95.0% 95.0% 95.0% 95.0% NOTES: All models are 115V, 60HZ,1 phase Gas connocilon slzo for all models, Is lk [13 mm] N.P.T. d) See Conversion Kit Index Form for high altitude dente. m Canadian Installatlous only. co In accordance with D.O.E. lost procedures. 'E ■Standard "N■NOx Models MODEL IDENTIFICATION Ia�E R G R C � M ® ( o o - o Rheem Gas Upflow/ Design Heating Input Blower Site Furnace Condensing Series Designation 11 x 7 Gas Furnace 1279 x 178 mm] R all x 10 [279 x 254 mm] Z ■12x11 - (305 x 279 mm) [ I DeWgnaocs Metric Conversions d) O nations Sld. HeaUCool Deslgnatlon I Code S .S. and Cabinot E>1100.1300 CFM Canadian B - Edo [510.613.5 Us] Natural Gas Cabinet G = 1500.1700 CFM [707.9.602.3 Us] J a 1900 -2100 CFM [896.7 -991.1 Us] Rheem Heating, Cooling and Water Heating I,NOV- 05- 2010(FRI) 0Q,09 P.006/006 UPFLOW MODELS TOP [[�� mm OIA, I CON>SENSA 1 DRAIN r l 965 mm) 1 I 11 i OPTIONAL RETURN AIR CUTOUT I mm] ((EITHER SID FOR USE WITH ETERNAL 91�E FILTER F1�AME 1885 mm) 1241 mm) LEFT SIDE [672 mm] GAS C" =ON 7 >' /a'(� mm as (5 ELEA CONNECTION 261.' (876 mm) (HIGH VOLTAGE) ? /s' 122 mm,] OIA. — 27 ------ CoW TALE I . (895 mm) rR 25112 (848 mm] A 19 1' . (16 mm) 9 115 mmI F_ SUPPLY AIR 19 ml ALT COMBUSTION AIR IN FRONT I= =30 11 ple' 1292 mm1 W [m 24 i1 I ola 24"s• 118 mm[ . 2• 161 mml DIA- KNOCOUT ALT. G CONNECTION [878 mm] 7. (� mm MA. KNOCImUT ALT. ELECfR�CAL CONNECTION nw* 122 mni DIA. IWOCIOUT I ALT Low vwme VVIRING I I i 1 1$' 1 71/a• 120 mm DUL IWOCKOUT 1381 mm[ I ALT. CONDENSATE DRAIN 1 � I I � ry� )584 mml 2J hs' INS mm] RIGHT SIDI[f n[ 4 Flheem Heating, Cooling and Water Heating mml ?NT OUTLET r COVUSTION AIR INLET 147 /mm) ; :F all 28Hw' 110 mm) —�{ 1713 mml •x I r 0 115 mml D I � 16o�mm1 141111 � 27*1/r' ]710 [ ] Designates Motrlo Convemlons MINIMUM CLEARANCE (IN.) [mm] SNIP MODEL RGRC• A 8 C D E F SIDE RIGHT SACK TOP FRONT VENT WETS. [k01 SIDE 04EM 171/214451 1611/32 [415] 15 [397] 2 [51] 15 14221 1394m [352] 0 0 0 1 2 [51 0 111 [50] OSEM 17 (445] 16 (415] 15514 [397] 2 [511 15 14221 13a/m 1352 0 0 0 1251 2 [51] 1 0 1 117 [531 7EM 17 (4451 18 /3z (415) 15 2151 15 4221 13m/n [952] 0 0 0 1 2 1511 0 124 [561 7 ER 21 [533] 192 [504] 19 2 (611 16 (511] 17o /2z (441] 0 0 0 1 (25] 2151 0 137 521 9EZ rQ10E 21 1533 1977/3z 5041 19 [4871 2 [51) 181h [5111 17 (441 0 0 0 1 251 2 51 ] 0 148 [67] 21 [533] 1927/32 504] 19 [487] 2 [51] 18 15111 179/32 (441] 0 0 0 1 (25] 2 [51] 0 1521691 4 Flheem Heating, Cooling and Water Heating mml ?NT OUTLET r COVUSTION AIR INLET 147 /mm) ; :F all 28Hw' 110 mm) —�{ 1713 mml •x I r 0 115 mml D I � 16o�mm1 141111 � 27*1/r' ]710 [ ] Designates Motrlo Convemlons 12 -03 -2010 Inspection Request Reporting Page 25 8:52 am Vail, CO - City Of Requested Inspect Date: Friday, December 03, 2010 Inspection Area: MH Site Address: 5040 MAIN GORE PL VAIL SUNDIAL UNIT A -1 A /P /D Information Activity: M10 -0272 Type: B -MECH Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: MH Owner: LANGEREIS, ARTHUR HENRY Contractor: JERRY SIBLEY PLUMBING Phone: 970 - 827 -5736 Description: FURNACE REPLACEMENT, INSTALL NEW SEALED COMBUSTION FLUE: 75,000 BTU 95% Requested Inspe Item: Requestor: Comments: Assigned To: ction: ction s 39 MECH -Final JERRY SIBLEY PLU BING UNIT A -1, CALL 30 NUTES PRIOR Time Exp: . Requested Time: 10:30 AM Phone: 970 - 827 -5736 Entered By: DRHOADES K J Inspection History Item: 310 MECH- Heating Item: 390 MECH -Final jlr E C Jai v � � � L lei 5 V �� v� S� REPT131 Run Id: 245