HomeMy WebLinkAboutM10-0279 VOIDNOV -17 -2010 08:02 FROM: ❑ Complete Mechanical Room Floor Plan with Dimensions ❑ Combustion Air Duct Size and Location X Flue detail or Vent size, location & termination Q Gas Piping layout including development length calculations ❑ Heat Loss Calculations Project Street Address: —26e�L. L 4 RK PU 2 uE — (Number) (Street) (Suite ) Building /Complex Name: At IA TO:19704792452 P.2/8 ❑ Boiler size & efficiency (, Equipment Cut Sheets for Fireplaces /Log Sets Manufacturer's info showing make. model & approval listin Office use; Project #: PR f N &2 Building Permit #: I Mechanical Permit #: I in D 2 2 Lot #: Block # Subdivision: caner ame. � /Y _. �..__._. _,, ..,,.._� .._ ......,.- - - -... .. .. .. . Date Received: Complete Valuation for Mechanical Permit: (including fireplaces) Mechanical $; 17- �7 0 NOV 17 2010 TOWN OF VAIL C:\ cdev\ formelpermitslbuilding \ntechunicul ,pcnnit_010110 MECHANICAL PERMIT Define Scope and Location of Work: 2n5 0 o/1 Contractor Information: � � Company: 0Dun a A OP.S� f�6 W 1 C Ca b, n� ► ita!► 1 22 � � 7 1 ` f Ve a L is 1 114 Pi � �ir Company Address: 0� I` J City; A State: Q Zip: ot 3q ' X3 > l4T 0 7 (use additional sheet If n• nary) Contact Name. .� ,�� _ / � - 1 am OI Contact Phone � ( ✓ 0 _t r.� Gas Piping Included ❑ Gas Piping by Others t� t1 E -Mail _ -14KE ID / � � 7 4 R C 0 M ❑ Wood to Gas Fireplace Conversion Town of Vail Contractor Re ' tration No.: 1 + 8' Boiler Location: Interior ( ) Exterior ( ) Other ( ) r Number of Existing Fireplaces: Gas Appliances Gas Logs Wood /Pellet Co ractor Sign ure (required) _ Property Information Parcel #: Z `D 3 4 O . .. - - - .. 1 ......-­ .... ,._ .....-. . __ Number of Proposed Fireplaces: (For parcel 0, contact Eagle County Asbessors Office at 870- 328 -8640 or Gas Appliances Gas Logs Wood /Pellet l visit wwwmaglecounty.us /patie) ... ........ _....__.... �1 Tenant Name, /,4 Type of Building: U ( omm rcial Pr a ies) 0 N n " ( O single - Family Y�1 Duplex ( ) Multi - Family ( ) Commercial ( ) Restaurant ( ) Other ( ) caner ame. � /Y _. �..__._. _,, ..,,.._� .._ ......,.- - - -... .. .. .. . Date Received: Complete Valuation for Mechanical Permit: (including fireplaces) Mechanical $; 17- �7 0 NOV 17 2010 TOWN OF VAIL C:\ cdev\ formelpermitslbuilding \ntechunicul ,pcnnit_010110 MECHANICAL PERMIT NOV -17 -2010 08:02 FROM: r ���N 7001 Highway 73, Evergreen, CO. 80439 TeL (303)670 0S8 /674.9377 Rix: (303)679.1592 ofrice@MtnHP.com www.MtnHP.com 16 November 2010 To: Town of Vail - TOV Building Department Attn: Mr, David Rhoades 75 South Frontage Road Vail CO 81657 From: Jake T Johnson President Dear David, TO:19704792452 P.1 /8 Please find attached our Mechanical Permit to install a. Morso Model 5660 woodstove insert and zero - clearance cabinet in the home of Ms. Sheila Sullivan at 2645 Larkspur Lane in Vail, Colorado. The woodstove is EPA Phase 11 Certified and U, Listed —see attached pages. The scope of our work will include: a. Installation of the ZC cabinet onto a previously constructed base b. Installation of the 5660 insert into the cabinet c. Connection of the insert to the cabinet d, Installation of a Metal Fab TempGuard chimney system. 1. 6" interior diameter chimney listed to UL 14T103 2. 2" clearance to combustible materials 3. Vertical rise of approximately 18' 4. Roof flashing for 4/12 pitched roof 5. Storm collar and chimney cap w /spark - arresting screen 6. Interior lirestop plate at ceiling. e, Installation of optional outside air kit adapter and termination Dates of operation -- December 4' , 2010 Onsite owner representative — Sheila Sullivan (VRC) Onsite project supervisor — Nick Wallbank (M.R &P) Please contact me with any problems or if you need any more infonration. Respectfully submitted — Jake JaV T Jb nson CSIA / 14FI / FIRE D I�C�L dMC� D NOV 17 2010 TOWN OF VAIL NOU -17 -2010 08:03 FROM: TO :19704792452 P.3/8 T By appointment to Tho Royal Danish Court rso Installation and Operating Instructions 5660 Standard Insert For use in North America Read this entire manual before you install and use your new room heater. If this room heater is not properly Installed, a house fire may result. To reduce the risk of fire, follow the installation Instructions. Failure to follow Instructions may result In property damage, bodily injury, or even death, Contact local building officials about restrictions and installation /inspection- requlrements In your area. Save these instructions MORSO JERNSTOSERI A/S . OK -7900 NYKOBING MORS E -Mail: stoves ®morsoe.com - Website: www.morsoe.com Distributed by: MORSO US LLC 1011 Highway 52 West - Portland TN - 37148 - USA Website: www.morsousa.com NOU -17 -2010 08:03 FROM: TO:19704792452 P.4/8 We congratulate you on your choice of a Morso stove. Morso has been producing some of the world's best stoves since 1853. If you follow this installation- and operating instruction carefully, we can assure you many years of warmth and pleasure, Optional Accessories A wide range of accessories (such as handling gloves, fireside tools, glass cleaner and heatproof paint) are available for use with your Morso stove. They help with day -to -day running and maintenance. Contact your Morso dealer for more Information. The Morso 5660 Standard Insert masts the U.S. Environmental Protectlon Agency's emission limits for wood heaters sold on or after July 1, 1990 The Mureo 5690 Standard Insert havo bean tasted by OMNI -Test Laboratories, Inc. The lost standards ore ANSI /UL -1482 for the United States and ULC 5627 for Canada. iYhe stove Is listed for burning wood only. Do not burn other fuels. 2 w►YforuL We recommend that our pellet hearth jNR�Tr products be installed and serviced by FR professionals who are certified in the U.S. by the National Fireplace InstituteP (NFI) as NFI Pellet Specialists or who are certified in Canada by d IED Energy Technical L.. okwdiwuq Training (WETT) .......,..... NOV -17 -2010 08:03 FROM: TO:19704792452 P.5/8 1.1 The chimney / flue system Note that the flue system must be independently secured and must not rely on tho stove for r,upport, The stove must not be connected to a chimney flue serving any other appliance. (Several flues may run up a single chimney stack; use one flueway per appliance). Use a residential type masonry or listed type HT factory built chimney, High Temperature (H.T.) Chimney Standard UL- 103.1885 (2100 F,) for the USA, and High Temperature (650 °C) Standard ULC S•629 for Canada. The Internal dimensions of the chimney connector and chimney must not be less than a Inches diameter (or equivalent cross section), and should not be significantly larger then this. Too large a section will tend to allow the flue gases to cool excessively, causing sluggishness or unpredictability in the stove's performance. We recommend the length of the chimney system should be at least 16 feet (not required) above the stove in normal domestic situatlons, measured from the flue collar to the top of the chimney. Local conditions like for example - roof constructions, large trees nearby and high altitude, may influence the chimney draft and height. Therefore, contact the local professional chimney sweep or your Morso dealer. Do not connect to any air distribution duct or system. Important: If the installation Instructions are not followed carefully, It may cause dan- gerous situations like chimney • and house fires. Follow the instructions carefully and do not deviate from them as it may cause injuries to people or property. NOU -17 -2010 08:03 FROM: ■ ' . TO:19704792452 .;t;. By appointment to The Royal Danish Court P. 6/8 11 • • energy wood efficient stoves MORSO 5660 Fireplace Insert Zero Clearance Enclosure ENCLOSURE MODEL 90566400 FOR INSERT MODEL 566ONA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD Morso US LLC 1011 Hwy. 52 West Portland, TN 37148 TEL: (615) 323 0561 iMUd d. Pomana usled By . Orapoa USA us OUNI.Taa1 Laborarorlen, Inc. Roport # 192-S-22-2 NOO -17 -2010 08:04 FROM: T0:19704792452 P.7/8 Installing the Morso 5660Fireplace Insert Zero Clearance Enclosure PRODUCT SAFETY THESE FIREPLACE INSERT ZERO CLEARANCE ENCLOSURES ARE A LISTED COMPONENT FOR AND ARE INTENDED FOR USE WITH THE MORSO MODELS 5660 STANDARD AND 566ONA W000- BURNING FIREPLACE INSERTS ONLY. DO NOT USE OTHER PRODUCTS NOT SPECIFIED OR LISTED FOR USE WITH THESE ENCLOSURES. WARNING: IF THESE ENCLOSURES AND FIREPLACE INSERTS ARE NOT PROPERLY IN- STALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE IN- STALLATION INSTRUCTIONS EXACTLY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. IT IS A GOOD IDEA TO REVIEW YOUR PLANS WITH THEM BEFORE BEGINNING THE INSTAL- LATION, ASK YOUR MORSO AUTHORIZED DEALER FOR HELP WITH LOCAL OFFICIALS IF NEEDED. WHEN INSTALLLED IN THESE FIREPLACE INSERT ZERO CLEARANCE ENCLOSURES IN THE UNITED STATES, THE MORSO MODELS 5660 STANDARD AND 566ONA FIREPLACE INSERTS MUST ONLY BE CONNECTED TO ONE OF THE SPECIFIC CHIMNEYS LISTED ON PAGE 4 OF THIS MANUAL. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THE FIREPLACE IN- SERT ZERO CLEARANCE ENCLOSURE AND MORSO MODEL 5660 STANDARD OR 5660NA FIREPLACE INSERT. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. FOR FURTHER INFORMATION, REFER TO THE NATIONAL FIRE PROTECTION ASSOCIATION ANSI /NFPA 211 STANDARD FOR CHIMNEYS, FIREPLACES, VENTS AND SOLID FUEL BURN- ING APPLIANCES. REFER TO THE MORSO MODEL 5660 STANDARD OR 5660NA OPERATING INSTRUCTIONS FOR INFORMATION ON THE PROPER USE AND MAINTENANCE OF THE FIREPLACE INSERT. WARNING: THIS FIREPLACE INSERT ZERO CLEARANCE ENCLOSURE IS NOT A FIREPLACE. BUILDING A FIRE IN THE ENCLOSURE WITHOUT THE MORSO MODEL 5660 STANDARD OR 566ONA INSTALLED IS PROHIBITED AND MAY RESULT IN PROPERTY DAMAGE, BODILY IN- JURY OR EVEN DEATH. j NOV -17 -2010 08:04 FROM: TO:19704792452 P.8/8 Installing the Morso 5660 Fireplace Insert Zero Clearance Enclosure CHIMNEY REQUIREMENTS For proper draft and best performance, the chimney should extend at least 15' (4.6m) and not more than 35' (10.6m) above the level of the MORSO Model 5660 STANDARD or Model 5660NA hearth. The chimney must be properly installed and supported in accordance with the chimney manufac- turer's instructions. The enclosure is not intended to support the entire weight of the chimney. Sup- port components are available from the chimney manufacturer. If possible, an installation with a straight vertical chimney will provide the best draft and will be easi- est to clean. If a straight chimney is not possible due to obstructions, up to four 30° elbows may be used to offset the chimney around the obstructions. The elbows must be used in pairs in order to return the chim- ney to vertical after passing the obstruction. The first offset must be at least 8' (2.5m) above the Insert hearth. The Morso 5660 Fireplace Insert Zero Clearance Enclosures are approved for installation in the United States with the following chimneys: Metal Fab, Inc. Security Chimneys Selkirk Metalbest Simpson -Dora -Vent Model TG Model ASHT Model Ultra -Temp Model Dura -Plus (SDP) The chimney installation begins with a base plate or anchor plate mounted to the top of the Fireplace Insert zero Clearance Enclosure. Before the base plate is installed on the enclosure top, the flexible stainless steel flue connector (provided with the enclosure) that will connect the Insert to the chim- ney system must be attached to the base plate using the four provided sheet metal fasteners. See FIG. 1. Next, insert the anchor plate /flex connector assembly down through the hole in the top of the enclosure. Use the four provided sheet metal fasteners to secure the base /anchor plate to the enclosure top. Next slide the stainless steel 45° slip connector elbow all the way onto the stainless flex connector in preparation for installing the Insert. 110000000� Chimney Basel Anchor Plate Sheet Metal Fasteners •� Stainless Steel Flex Connector Stainless Steel 45° Slip Elbow FIG. 1