HomeMy WebLinkAboutM10-0279 VOIDNOV -17 -2010 08:02 FROM:
❑ Complete Mechanical Room Floor Plan with Dimensions
❑ Combustion Air Duct Size and Location
X Flue detail or Vent size, location & termination
Q Gas Piping layout including development length calculations
❑ Heat Loss Calculations
Project Street Address:
—26e�L. L 4 RK PU 2 uE —
(Number) (Street) (Suite )
Building /Complex Name: At IA
TO:19704792452 P.2/8
❑ Boiler size & efficiency
(, Equipment Cut Sheets for Fireplaces /Log Sets
Manufacturer's info showing make. model & approval listin
Office use;
Project #: PR f N &2
Building Permit #: I
Mechanical Permit #: I in D 2 2
Lot #: Block # Subdivision:
caner ame. � /Y
_. �..__._. _,, ..,,.._� .._ ......,.- - - -... .. .. .. . Date Received:
Complete Valuation for Mechanical Permit: (including fireplaces)
Mechanical $; 17- �7 0
NOV 17 2010
TOWN OF VAIL
C:\ cdev\ formelpermitslbuilding \ntechunicul ,pcnnit_010110
MECHANICAL PERMIT
Define Scope and Location of Work: 2n5 0 o/1
Contractor Information: � �
Company: 0Dun a A OP.S� f�6 W 1 C Ca b, n�
►
ita!► 1 22 � �
7
1 ` f
Ve a L is 1 114 Pi � �ir
Company Address: 0� I` J
City; A State: Q Zip: ot 3q
'
X3 >
l4T 0
7
(use additional sheet If n• nary)
Contact Name.
.� ,�� _ / � - 1 am OI
Contact Phone � ( ✓ 0 _t
r.� Gas Piping Included
❑ Gas Piping by Others
t� t1
E -Mail _ -14KE ID / � � 7 4 R C 0 M
❑ Wood to Gas Fireplace Conversion
Town of Vail Contractor Re ' tration No.: 1 + 8'
Boiler Location:
Interior ( ) Exterior ( ) Other ( ) r
Number of Existing Fireplaces:
Gas Appliances Gas Logs Wood /Pellet
Co ractor Sign ure (required)
_
Property Information
Parcel #: Z `D 3 4 O
. .. - - - .. 1 ......- .... ,._ .....-. . __
Number of Proposed Fireplaces:
(For parcel 0, contact Eagle County Asbessors Office at 870- 328 -8640 or
Gas Appliances Gas Logs Wood /Pellet
l
visit wwwmaglecounty.us /patie)
... ........ _....__....
�1
Tenant Name, /,4
Type of Building:
U
( omm rcial Pr a ies)
0 N n " ( O
single - Family Y�1 Duplex ( ) Multi - Family ( ) Commercial ( )
Restaurant ( ) Other ( )
caner ame. � /Y
_. �..__._. _,, ..,,.._� .._ ......,.- - - -... .. .. .. . Date Received:
Complete Valuation for Mechanical Permit: (including fireplaces)
Mechanical $; 17- �7 0
NOV 17 2010
TOWN OF VAIL
C:\ cdev\ formelpermitslbuilding \ntechunicul ,pcnnit_010110
MECHANICAL PERMIT
NOV -17 -2010 08:02 FROM:
r
���N
7001 Highway 73, Evergreen, CO. 80439
TeL (303)670 0S8 /674.9377 Rix: (303)679.1592
ofrice@MtnHP.com
www.MtnHP.com
16 November 2010
To: Town of Vail - TOV Building Department
Attn: Mr, David Rhoades
75 South Frontage Road
Vail CO 81657
From: Jake T Johnson
President
Dear David,
TO:19704792452 P.1 /8
Please find attached our Mechanical Permit to install a. Morso Model 5660 woodstove insert
and zero - clearance cabinet in the home of Ms. Sheila Sullivan at 2645 Larkspur Lane in
Vail, Colorado.
The woodstove is EPA Phase 11 Certified and U, Listed —see attached pages.
The scope of our work will include:
a. Installation of the ZC cabinet onto a previously constructed base
b. Installation of the 5660 insert into the cabinet
c. Connection of the insert to the cabinet
d, Installation of a Metal Fab TempGuard chimney system.
1. 6" interior diameter chimney listed to UL 14T103
2. 2" clearance to combustible materials
3. Vertical rise of approximately 18'
4. Roof flashing for 4/12 pitched roof
5. Storm collar and chimney cap w /spark - arresting screen
6. Interior lirestop plate at ceiling.
e, Installation of optional outside air kit adapter and termination
Dates of operation -- December 4' , 2010
Onsite owner representative — Sheila Sullivan (VRC)
Onsite project supervisor — Nick Wallbank (M.R &P)
Please contact me with any problems or if you need any more infonration.
Respectfully submitted — Jake
JaV T Jb nson
CSIA / 14FI / FIRE
D I�C�L dMC� D
NOV 17 2010
TOWN OF VAIL
NOU -17 -2010 08:03 FROM: TO :19704792452 P.3/8
T
By appointment to Tho Royal Danish Court
rso
Installation and Operating Instructions
5660 Standard Insert
For use in North America
Read this entire manual before you install and use your new room heater. If this room
heater is not properly Installed, a house fire may result. To reduce the risk of fire, follow
the installation Instructions. Failure to follow Instructions may result In property damage,
bodily injury, or even death,
Contact local building officials about restrictions and installation /inspection- requlrements
In your area.
Save these instructions
MORSO JERNSTOSERI A/S . OK -7900 NYKOBING MORS
E -Mail: stoves ®morsoe.com - Website: www.morsoe.com
Distributed by: MORSO US LLC
1011 Highway 52 West - Portland TN - 37148 - USA
Website: www.morsousa.com
NOU -17 -2010 08:03 FROM:
TO:19704792452 P.4/8
We congratulate you on your choice of a Morso stove. Morso has
been producing some of the world's best stoves since 1853. If you
follow this installation- and operating instruction carefully, we can
assure you many years of warmth and pleasure,
Optional Accessories
A wide range of accessories (such as handling gloves, fireside tools, glass cleaner and heatproof
paint) are available for use with your Morso stove. They help with day -to -day running and
maintenance. Contact your Morso dealer for more Information.
The Morso 5660 Standard Insert masts the U.S. Environmental Protectlon Agency's emission
limits for wood heaters sold on or after July 1, 1990
The Mureo 5690 Standard Insert havo bean tasted by OMNI -Test Laboratories, Inc. The lost
standards ore ANSI /UL -1482 for the United States and ULC 5627 for Canada.
iYhe stove Is listed for burning wood only. Do not burn other fuels.
2
w►YforuL We recommend that our pellet hearth
jNR�Tr products be installed and serviced by
FR professionals who are certified in the U.S.
by the National Fireplace InstituteP (NFI)
as NFI Pellet Specialists or who are
certified in Canada by d
IED Energy Technical
L.. okwdiwuq Training (WETT) .......,.....
NOV -17 -2010 08:03 FROM: TO:19704792452 P.5/8
1.1 The chimney / flue system
Note that the flue system must be independently secured and must not rely on tho stove for
r,upport,
The stove must not be connected to a chimney flue serving any other appliance.
(Several flues may run up a single chimney stack; use one flueway per appliance).
Use a residential type masonry or listed type HT factory built chimney,
High Temperature (H.T.) Chimney Standard UL- 103.1885 (2100 F,) for the USA, and
High Temperature (650 °C) Standard ULC S•629 for Canada.
The Internal dimensions of the chimney connector and chimney must not be less than a Inches
diameter (or equivalent cross section), and should not be significantly larger then this. Too
large a section will tend to allow the flue gases to cool excessively, causing sluggishness or
unpredictability in the stove's performance.
We recommend the length of the chimney system should be at least 16 feet (not required) above
the stove in normal domestic situatlons, measured from the flue collar to the top of the chimney.
Local conditions like for example - roof constructions, large trees nearby and high altitude, may
influence the chimney draft and height. Therefore, contact the local professional chimney sweep or
your Morso dealer.
Do not connect to any air distribution duct or system.
Important: If the installation Instructions are not followed carefully, It may cause dan-
gerous situations like chimney • and house fires. Follow the instructions carefully and
do not deviate from them as it may cause injuries to people or property.
NOU -17 -2010 08:03 FROM:
■ ' .
TO:19704792452
.;t;.
By appointment to The Royal Danish Court
P. 6/8
11 • •
energy
wood
efficient
stoves
MORSO 5660 Fireplace Insert
Zero Clearance Enclosure
ENCLOSURE MODEL 90566400 FOR INSERT MODEL 566ONA
And
ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD
Morso US LLC
1011 Hwy. 52 West
Portland, TN 37148
TEL: (615) 323 0561
iMUd d. Pomana
usled By . Orapoa USA
us
OUNI.Taa1 Laborarorlen, Inc.
Roport # 192-S-22-2
NOO -17 -2010 08:04 FROM: T0:19704792452 P.7/8
Installing the Morso 5660Fireplace Insert Zero Clearance Enclosure
PRODUCT SAFETY
THESE FIREPLACE INSERT ZERO CLEARANCE ENCLOSURES ARE A LISTED COMPONENT
FOR AND ARE INTENDED FOR USE WITH THE MORSO MODELS 5660 STANDARD AND
566ONA W000- BURNING FIREPLACE INSERTS ONLY. DO NOT USE OTHER PRODUCTS
NOT SPECIFIED OR LISTED FOR USE WITH THESE ENCLOSURES.
WARNING: IF THESE ENCLOSURES AND FIREPLACE INSERTS ARE NOT PROPERLY IN-
STALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE IN-
STALLATION INSTRUCTIONS EXACTLY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS
ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
IT IS A GOOD IDEA TO REVIEW YOUR PLANS WITH THEM BEFORE BEGINNING THE INSTAL-
LATION, ASK YOUR MORSO AUTHORIZED DEALER FOR HELP WITH LOCAL OFFICIALS IF
NEEDED.
WHEN INSTALLLED IN THESE FIREPLACE INSERT ZERO CLEARANCE ENCLOSURES IN THE
UNITED STATES, THE MORSO MODELS 5660 STANDARD AND 566ONA FIREPLACE INSERTS
MUST ONLY BE CONNECTED TO ONE OF THE SPECIFIC CHIMNEYS LISTED ON PAGE 4 OF
THIS MANUAL.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THE FIREPLACE IN-
SERT ZERO CLEARANCE ENCLOSURE AND MORSO MODEL 5660 STANDARD OR 5660NA
FIREPLACE INSERT. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY
DAMAGE, BODILY INJURY OR EVEN DEATH.
FOR FURTHER INFORMATION, REFER TO THE NATIONAL FIRE PROTECTION ASSOCIATION
ANSI /NFPA 211 STANDARD FOR CHIMNEYS, FIREPLACES, VENTS AND SOLID FUEL BURN-
ING APPLIANCES.
REFER TO THE MORSO MODEL 5660 STANDARD OR 5660NA OPERATING INSTRUCTIONS
FOR INFORMATION ON THE PROPER USE AND MAINTENANCE OF THE FIREPLACE INSERT.
WARNING: THIS FIREPLACE INSERT ZERO CLEARANCE ENCLOSURE IS NOT A FIREPLACE.
BUILDING A FIRE IN THE ENCLOSURE WITHOUT THE MORSO MODEL 5660 STANDARD OR
566ONA INSTALLED IS PROHIBITED AND MAY RESULT IN PROPERTY DAMAGE, BODILY IN-
JURY OR EVEN DEATH.
j
NOV -17 -2010 08:04 FROM: TO:19704792452 P.8/8
Installing the Morso 5660 Fireplace Insert Zero Clearance Enclosure
CHIMNEY REQUIREMENTS
For proper draft and best performance, the chimney should extend at least 15' (4.6m) and not more
than 35' (10.6m) above the level of the MORSO Model 5660 STANDARD or Model 5660NA hearth.
The chimney must be properly installed and supported in accordance with the chimney manufac-
turer's instructions. The enclosure is not intended to support the entire weight of the chimney. Sup-
port components are available from the chimney manufacturer.
If possible, an installation with a straight vertical chimney will provide the best draft and will be easi-
est to clean.
If a straight chimney is not possible due to obstructions, up to four 30° elbows may be used to offset
the chimney around the obstructions. The elbows must be used in pairs in order to return the chim-
ney to vertical after passing the obstruction. The first offset must be at least 8' (2.5m) above the
Insert hearth.
The Morso 5660 Fireplace Insert Zero Clearance Enclosures are approved for installation in the
United States with the following chimneys:
Metal Fab, Inc.
Security Chimneys
Selkirk Metalbest
Simpson -Dora -Vent
Model TG
Model ASHT
Model Ultra -Temp
Model Dura -Plus (SDP)
The chimney installation begins with a base plate or anchor plate mounted to the top of the Fireplace
Insert zero Clearance Enclosure. Before the base plate is installed on the enclosure top, the flexible
stainless steel flue connector (provided with the enclosure) that will connect the Insert to the chim-
ney system must be attached to the base plate using the four provided sheet metal fasteners. See
FIG. 1.
Next, insert the anchor plate /flex connector assembly down
through the hole in the top of the enclosure. Use the four
provided sheet metal fasteners to secure the base /anchor
plate to the enclosure top.
Next slide the stainless steel 45° slip connector elbow all
the way onto the stainless flex connector in preparation for
installing the Insert.
110000000�
Chimney Basel
Anchor Plate
Sheet Metal
Fasteners
•� Stainless Steel
Flex Connector
Stainless Steel
45° Slip Elbow
FIG. 1