Loading...
HomeMy WebLinkAboutBinder1 6045 E. 76th Ave., Unit #12, Commerce City, CO 80022 Phone: (303) 288-3901 Fax: (303) 288-1936 www.allstatefireprotection.com Fire Sprinkler Equipment Submittal For Dennis Basso Shop 1 Vail Rd., Four Seasons Unit 5411 Vail, CO 81657 Series RFII — 5.6 K-factor “Royal Flush II” Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage Technical Services: Tel: (800) 381-9312 /Fax: (800) 791-5500 Email: techserv@tycofp.com Page 1 of 6 OCTOBER 2009 TFP181 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. General Description The Tyco® Series RFII Quick Response (3-mm bulb) and Standard Response (5-mm bulb), 5.6 K-Factor, “Royal Flush II” Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly. The separable, two-piece assembly design provides the following benefits: • Allows installation of the sprinklers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. • Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. • Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Protective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Protective Cap. When ceiling installation is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) “Royal Flush II” Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. NOTICE The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 — 3 mm bulb TY3551 — 5 mm bulb TFP181 Page 2 of 6 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. • TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, LPCB Approved (Ref. No. 094a/10), VdS Approved (Certificate No. G 4090007), and NYC Approved (MEA 353-01-E) as Quick Response. • TY3531 (3-mm Bulb) is FM Approved as Standard Response. Factory Mutual does not approve any concealed sprinklers for quick response. • TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F/68°C Sprinkler with 139°F/59°C Plate 200°F/93°C Sprinkler with 165°F/74°C Plate Discharge Coefficient K= 5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . Bronze Support Cup . . . Chrome Plated Steel Guide Pins . . . . . . . . . . Stainless Steel Deflector . . . . . . . . . . . . . . . . . Bronze Compression Screw . . . . . . . . . Brass Bulb . . . . . . . . . . . . . . . . . . . . . . Glass Cap . . . . . . . . . . . . Bronze or Copper Sealing Assembly . . . . . . . . Beryllium Nickel w/Teflon† Cover Plate . . . . . . . . . . . . . . . . Brass Retainer . . . . . . . . . . . . . . . . . . . Brass Ejection Spring . . . . . . Stainless Steel SPRINKLER/SUPPORT CUP ASSEMBLY COVER PLATE/RETAINER ASSEMBLY GUIDE DEFLECTOR (DROPPED POSITION) PINS (2) SCREW COMPRESSION DEFLECTOR ROLL FORMED THREADS CUP WITH SUPPORT FRAME 1/2" NPT CAP BULB SEALING ASSEMBLY RETAINER WITH THREAD DIMPLES SPRING EJECTION TABS (3) SOLDER COVER PLATE THREAD INTO UNTIL MOUNTING SUPPORT CUP SURFACE IS FLUSH WITH CEILING FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Design Criteria The Tyco® Series RFII Concealed Pendent Sprinklers are intended for fire protection systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Suppression & Building Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. NOTICE Do not use the Series RFII in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. †DuPont Registered Trademark TFP181 Page 3 of 6 CLEARANCE HOLE Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector—supported by the Guide Pins—then drops down to its operational position. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. FIGURE 4 DISPOSABLE PROTECTIVE CAP COVER PLATE PROFILE DEPTH DIMENSION B 1/2" (12,7 mm) THREADED D ADJUSTMENT SPRINKLER FACE OF FITTING RETAINER ASSEMBLY MANUFACTURER 3/32" (2,4 mm) PRESET GAP FACE OF CEILING, RETAINING RING MOUNTING SURFACE SUPPORT CUP SPRINKLER ASSEMBLY DIAMETER CLEARANCE HOLE DEFLECTOR IN DROPPED POSITION (4,8 to 17,5 mm) 3/16" to 11/16" REFERENCE COVER PLATE COVER PLATE DIAMETER DIMENSION A DIMENSION C A: 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) B: 3/16 inches (4,8 4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FRAME ARM SUPPORT CUP 7/8" (23 mm) SQUARE 1/2" SOCKET ACCEPTS DRIVE ARROWS WITH ALIGN FRAME ARMS FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS FIGURE 3 RFII SPRINKLER WRENCH TFP181 Page 4 of 6 Installation The Tyco® Series RFII must be installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C and 3/32 inch (2,4 mm) for the 200°F/93°C temperature ratings. Obtain a 1/2 inch NPT sprinkler joint by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler by under-or over-tightening the Sprinkler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Protective Cap. NOTICE As long as the Protective Cap remains in place, the system is considered “Out of Service”. Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly sufficiently to contact the ceiling, you must reposition the Sprinkler Fitting. Care and Maintenance The Tyco® Series RFII must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler operation in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Replace sprinklers that: • are leaking or exhibiting visible signs of corrosion. • were modified or over-heated. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. If necessary, replace them with factory-painted units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of a fire. Exercise care to avoid damage to sprinklers before, during, and after installation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. Responsibility lies with sprinkler owners for the inspection, testing, and maintenance of their fire protection system and devices in in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national code. CUP SUPPORT ROOM SEAL PLATE RETAINER SPRINKLER CLEAN PLATE COVER RETAINER LIP OF FACE OF CEILING BEVEL AS ORIENT SEAL ASSEMBLY COVER SHOWN FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) TFP181 Page 5 of 6 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for products or components manufactured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP’s sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP’s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: (SIN), (temperature rating from below) Series RFII Concealed Pendent Sprinkler, P/N (specify). 155°F/68°C 200°F/93°C TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F/59°C(a) 165°F/74°C(b) Brass. . . . . . . . . . . 56-792-1-135 56-792-1-165 Chrome. . . . . . . . . 56-792-9-135 56-792-9-165 Signal White (RAL 9003). . . . . 56-792-4-135 56-792-4-165 Grey White (RAL 9002). . . . . 56-792-0-135 56-792-0-165 Pure White (c) (RAL 9010). . . . . 56-792-3-135 56-792-3-165 Custom. . . . . . . . . 56-792-X-135 56-792-X-165 (a) For use with 155°F/68°C sprinklers. (b) For use with 200°F/93°C sprinklers. (c) Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. ©2008 -2009 TYCO FIRE SUPPRESSION & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 TFP181 Page 6 of 6 General Description The Series TY-L , 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response -standard coverage, solder type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, offices, etc. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling.Horizontal sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations where piping across the ceiling is not desirable. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series TY-L Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY3311 -HSW 5.6K, 1/2"NPT TY3311 is a redesignation for S1803 and G3113. Technical Data Approvals UL and C-UL Listed. FM Approved. (Refer to Table A for complete approval information.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table A Physical Characteristics Frame . . . . . . . . . . . . . Brass Sealing Button . . . Bronze w/Teflon† Ejection Spring . . . Stainless Steel Fusible Element . . . Solder, Copper . . . . . . . . . . . . Stainless Steel Strut . . . . . . . . . . . . . . Monel Hook . . . . . . . . . Bronze/Monel Deflector . . . . . . . . . . . Bronze † DuPont Registered Trademark Operation A copper tube sealed by two stainless steel balls holds a fusible alloy. When the rated temperature is reached, the alloy melts, the balls are forced toward each other releasing the tension mechanism, allowing the sprinkler to operate. Page 1 of 4 JULY, 2004 TFP120 Series TY-L — 5.6 K-factor Horizontal Sidewall Sprinklers Standard Response, Standard Coverage Technical Services: Tel: (800) 381-9312 /Fax: (800) 791-5500 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Design Criteria The 5.6 K-factor, Series TY-L Horizontal Sidewall Sprinklers are intended for fire protection systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Series TY-L Horizontal Sidewall Sprinkler must be installed with a deflector to ceiling distance of 4 to 6 inches (100 to 150 mm). To meet this requirement the centerline of the sprinkler waterway must be located 4-5/16 to 6-5/16 inches (110 to 160 mm) below the ceiling. Installation of the Series TY-L Horizontal Sidewall Sprinklers in recessed escutcheons will void all manufacturer’s warranties, as well as possibly void the sprinkler’s Approvals and/or Listings. Installation The Series TY-L Sprinklers must be installed in accordance with the following instructions:NOTES A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insufficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-L Horizontal Sidewall Sprinklers must be installed in accordance with the following instructions. Step 1. The Series TY-L Horizontal Sidewall Sprinklers must be installed with their centerline of waterway parallel to the ceiling and perpendicular to the back wall surface. The word “TOP” on the deflector must face upwards toward the ceiling. Step 2. After installing an escutcheon (as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 2), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figure 1, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area, or as applicable, the adjustable Crescent wrench is to be applied to the wrenching flanges. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just contact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be inspected and the wax coating retouched (repaired) whenever the coating has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gently applying a heated 1/8 inch diameter steel rod to the areas of wax that have Page 2 of 4 TFP120 FIGURE 1 STANDARD RESPONSE SERIES TY-L (TY3311) HORIZONTAL SIDEWALL SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 1 -Frame 2 -Sealing Button 3 -Ejection Spring 4 -Fusible Element 5 -Strut 6 -Hook 7 -Deflector * Temperature rating is indicated on deflector. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 W-TYPE 9 SPRINKLER WRENCH RECESS WRENCH WRENCHING CENTERLINE 7 TOP 3/8" (9,5 mm) 7/16" (11,1 mm) 1-1/2" (38,1 mm) (63,5 mm) 2-1/2" 1-7/8" NOMINAL MAKE-IN (47,6 mm) 7/16" (11,1 mm) OF WATERWAY SPRINKLER FLANGES WRENCHING 6 5 4 3 SURFACE PLATE SEATING ESCUTCHEON 2 1 NPT AREA 1/2" been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuccessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously described, touch the rod to the area requiring additional wax with the rod angled downward, and then touch the wax stick to the rod approximately one-half inch away from the area requiring retouching. The wax will melt and run down onto the sprinkler. Care and Maintenance The Series TY-L Sprinklers must be maintained and serviced in accordance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modified or over-heated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers -before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Frequent visual inspections are recommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products’ sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or TFP120 Page 3 of 4 TYPE TEMP. RATING FRAME COLOR CODE NATURAL BRASS CHROME PLATED SPRINKLER FINISH NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) for Light or Ordinary Hazard Occupancies. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) for Light or Ordinary Hazard Occupancies. 3. Approved by Factory Mutual Research Corporation (FM) for Light Hazard Occupancies. N/A: Not Available. TABLE A LABORATORY LISTINGS AND APPROVALS 5.6 1/2" NPT HORIZONTAL SIDEWALL (TY3311) 165°F/74°C Unpainted 212°F/100°C White 280°F/138°C Blue 1, 2, 3 K LEAD COATED WAX COATED WAX OVER LEAD COATED 1, 2 N/A incomplete information supplied by Buyer or Buyer’s representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS’ LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHERWARRANTIES EXPRESS OR IMPLIED, INCLUDINGWARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for availability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Standard Response, (specify K-factor), (specify temperature rating), Series TY-L Horizontal Sidewall Sprinkler with (specify type of finish), P/N (specify from Table B). Sprinkler Wrench: Specify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify temperature rating) temperature rated Series TY-L Sprinklers, P/N (specify). Red for 165°F . . . . . . . . . . . . . P/N 56-065-1-155 Blue for 212°F and 280°F . . . . . . . . . . . . . . . . . P/N 56-065-1-286 NOTES Each wax stick is suitable for retouching up to twenty-five sprinklers. The wax used for 280°F sprinklers is the same as for 212°F sprinklers, and, therefore, the 280°F sprinkler is limited to the same maximum ceiling temperature as the 212°F sprinkler (i.e., 150°F). Page 4 of 4 TFP120 P/N 53 — XXX — X — XXX 165 165°F/74°C TEMPERATURE RATING 1 SPRINKLER TABLE B PART NUMBER SELECTION SERIES TY-L HORIZONTAL SIDEWALL SPRINKLERS 212°F/100°C 280 280°F/138°C NATURAL BRASS 212 9 MODEL/SIN CHROME PLATED 113 5.6K HSW (1/2"NPT) TY3311 7 LEAD COATED 6 WAX WAX COATED 165°F and 212°F ONLY 7 WAX OVER LEAD 165°F and 212°F ONLY TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Eddythread 40 A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail: info@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 02/03 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: · Has a Corrosion Resistance Ratio of 1.0 · Has No Thread Warning · Has a Pressure Rating of 300 psi · Is Lighter Weight Than Schedule 40 · Is Approved by Factory Mutual and Listed by Underwriters Laboratories · Is Produced in Accordance to ASTM A-135 and A-795 · Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves · Is Produced From Steel With Excellent Properties of Strength and Threadability · Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* · Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS Nominal Pipe Size (in) Weight Lb./Ft I.D. (in) Bundle Size 1 1-1/4 1-1/2 2 1.600 2.139 2.562 3.364 1.090 1.425 1.655 2.124 70 51 44 30 CORROSION RESISTANCE RATIOS Nominal Pipe Size (in) Sch. 40 EDDYTHREAD 40 EDDYLITE 1 1-1/4 1-1/2 2 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.74 0.48 0.47 0.38 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems Page 21 D.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 DUCTILE IRON 90 DEG. ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 DB90033 500 1.50 1.50 0.62 1 1/4 DB90044 500 1.75 1.75 0.90 1 1/2 DB90055 500 1.94 1.94 1.20 2 DB90066 500 2.25 2.25 1.85 DIMENSIONS DUCTILE IRON STRAIGHT TEE NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 DT333 500 1.50 1.50 0.85 1 1/4 DT444 500 1.75 1.75 1.22 1 1/2 DT555 500 1.94 1.94 1.55 2 DT666 500 2.25 2.25 2.45 DIMENSIONS DUCTILE IRON RED.90 DEG. ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1X1/2 DB90031 500 1.26 1.36 0.44 1X3/4 DB90032 500 1.37 1.45 0.52 1 1/4X1/2 DB90041 500 1.34 1.53 0.64 1 1/4X3/4 DB90042 500 1.45 1.62 0.72 1 1/4X1 DB90043 500 1.58 1.67 0.75 1 1/2X1 DB90053 500 1.65 1.80 0.92 1 1/2X1 1/4 DB90054 500 1.82 1.88 1.08 2X1/2 DB90061 500 1.49 1.88 1.08 2X3/4 DB90062 500 1.60 1.97 1.24 2X1 DB90063 500 1.73 2.02 1.40 2X1 1/4 DB90064 500 1.90 2.10 1.52 2X1 1/2 DB90065 500 2.02 2.16 1.65 DIMENSIONS DUCTILE IRON COUPLING NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE 1 DCL033 500 1.67 0.40 1 1/4 DCL044 500 1.93 0.57 1 1/2 DCL055 500 2.15 0.75 2 DCL066 500 2.53 1.15 DUCTILE IRON RED. COUPLING NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE 1X1/2 DRC031 500 1.69 0.39 1X3/4 DRC032 500 1.69 0.53 DUCTILE IRON 45 DEG. ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 DB45033 500 1.12 1.12 0.46 1 1/4 DB45044 500 1.29 1.29 0.73 1 1/2 DB45055 500 1.43 1.43 0.92 2 DB45066 500 1.68 1.68 1.50 DIMENSIONS Ductile iron threaded fittings are UL, ULC listed and factory mutual approved for 500 psi service. Ductile iron per ASTM A 536 grade 65-45-12. Dimensions conform to ANSI B16.3 class 150. Threads are NPT per ANSI/ASME B1.20.1. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe pipe threads which may cause leakage. Ductile iron fittingd should be tightened theree turns beyond hand tight, but no more than four turns. A Page 22 DUCTILE IRON REDUCING TEE NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B C PIECE 1X1X1/2 DT331 500 1.26 1.26 1.36 0.64 1X1X3/4 DT332 500 1.37 1.37 1.45 0.73 1X1/2X1 DT313 500 1.50 1.36 1.50 0.71 1X3/4X1 DT323 500 1.50 1.45 1.50 0.76 1X1X1 1/4 DT334 500 1.67 1.67 1.58 0.98 1X1X1 1/2 DT335 500 1.80 1.80 1.65 1.16 1 1/4X1X1/2 DT431 500 1.34 1.26 1.53 0.82 1 1/4X1X3/4 DT432 500 1.45 1.37 1.62 0.90 1 1/4X1X1 DT433 500 1.58 1.50 1.67 1.00 1 1/4X1X1 1/4 DT434 500 1.75 1.67 1.75 1.08 1 1/4X1X1 1/2 DT435 500 1.88 1.80 1.82 1.42 1 1/4X1 1/4X1/2 DT441 500 1.34 1.34 1.53 0.86 1 1/4X1 1/4X3/4 DT442 500 1.45 1.45 1.62 0.92 1 1/4X1 1/4X1 DT443 500 1.58 1.58 1.67 0.95 1 1/4X1 1/4X1 1/2 DT445 500 1.88 1.88 1.82 1.45 1 1/4X1 1/4X2 DT446 500 2.10 2.10 1.90 1.75 1 1/2X1X1/2 DT531 500 1.41 1.34 1.66 0.95 1 1/2X1X3/4 DT532 500 1.52 1.37 1.75 1.14 1 1/2X1X1 DT533 500 1.65 1.50 1.80 1.17 1 1/2X1X1 1/4 DT534 500 1.82 1.67 1.88 1.34 1 1/2X1X1 1/2 DT535 500 1.94 1.80 1.94 1.45 1 1/2X1 1/4X1/2 DT541 500 1.41 1.34 1.66 1.05 1 1/2X1 1/4X3/4 DT542 500 1.52 1.45 1.75 1.15 1 1/2X1 1/4X1 DT543 500 1.65 1.58 1.80 1.25 1 1/2X1 1/4X2 DT546 500 2.16 2.10 2.02 1.90 1 1/2X1 1/2X1/2 DT551 500 1.41 1.41 1.16 1.15 1 1/2X1 1/2X3/4 DT552 500 1.52 1.52 1.75 1.24 1 1/2X1 1/2X1 DT553 500 1.65 1.65 1.80 1.30 1 1/2X1 1/2X1 1/4 DT554 500 1.82 1.82 1.88 1.48 1 1/2X1 1/2X2 DT556 500 2.16 2.16 2.02 1.98 2X1X2 DT636 500 2.25 2.02 2.25 2.15 2X1 1/4X2 DT646 500 2.25 2.10 2.25 2.30 2X1 1/2X1/2 DT651 500 1.49 1.41 1.88 1.50 2X1 1/2X3/4 DT652 500 1.60 1.52 1.97 1.62 2X1 1/2X1 DT653 500 1.73 1.65 2.02 1.64 2X1 1/2X1 1/4 DT654 500 1.90 1.82 2.10 1.80 2X1 1/2X1 1/2 DT655 500 2.02 1.94 2.16 2.00 2X1 1/2X2 DT656 500 2.25 2.16 2.25 2.35 2X2X1/2 DT661 500 1.49 1.49 1.88 1.60 2X2X3/4 DT662 500 1.60 1.60 1.97 1.68 2X2X1 DT663 500 1.73 1.73 2.02 1.85 2X2X1 1/4 DT664 500 1.90 1.90 2.10 2.04 2X2X1 1/2 DT665 500 2.02 2.02 2.16 2.18 2X2X2 1/2 DT556 500 2.60 2.60 2.39 3.61 2 1/2X2X3/4 DT762 500 1.74 1.60 2.32 2.28 DIMENSIONS DUCTILE IRON CAP NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE 1 DCP003 500 1.16 0.32 1 1/4 DCP004 500 1.28 0.43 1 1/2 DCP005 500 1.33 0.60 2 DCP006 500 1.45 0.91 DUCTILE IRON CROSS NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I A B PIECE 1 DX033 500 1.50 1.50 0.98 1 1/4 DX044 500 1.75 1.75 1.50 1 1/2 DX055 500 1.94 1.94 1.90 2 DX066 500 2.25 2.25 2.95 1 1/4X1 DX043 500 1.58 1.67 1.27 1 1/2X1 DX053 500 1.65 1.80 1.48 2X1 DX063 500 1.73 2.02 2.10 DIMENSIONS DT667 DUCTILE IRON BUSHINGS NOMINAL ITEM SIZE CODE (INCH) # DIMENSIONS 1x1/2 DBUSH31 0.75 0.25 1.42 OUT 1x3/4 DBUSH32 0.75 0.25 1.42 OUT 1 1/4x1 DBUSH43 0.80 0.28 1.76 OUT 1 1/2x1 DBUSH53 0.83 0.31 2.00 OUT 1 1/2x1 1/4 DBUSH54 0.83 0.31 2.00 OUT 2x1 DBUSH63 0.88 0.41 1.95 IN 2x1 1/4 DBUSH64 0.88 0.34 2.48 OUT 2x1 1/2 DBUSH65 0.88 0.34 2.48 OUT 0.22 0.17 0.28 0.44 0.30 0.66 0.72 0.61 DIMENSIONS A B C STYLE WT. EACH D.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 OUTSIDE HEAD INSIDE HEAD OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 66 www.tolco.com Revision 5/24/2001 ™® a brand of Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11⁄4 8000 7140 360 11⁄2 11630 10370 510 www.8/15/2005 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 98 -Rod Stiffener Fig. 99 -All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 -All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Component of State of California OSHPD Approved Seismic Restraints System | Visit Hilti Online US www.us.hilti.com Canada www.ca.hilti.com Listings/Approvals ICC-ES (International Code Council) Evaluation Report No. 5264 COLA (City of Los Angeles) Research Report No. 25350 FM (Factory Mutual) 4.3.7.4 Installation Instructions 4.3.7.5 Ordering Information 4.3.7.3 Technical Data Average Ultimate Loads, lb (kN) Allowable Loads, lb (kN) 4000 psi Concrete Hollow Core 4000 psi Concrete Hollow Core Length Bit Size1 (27.6 MPa) (Spancrete) (27.6 MPa) (Spancrete) Desc. in. (mm) in. Tension Shear Tension Shear Tension Shear Tension Shear HDI-P 3/8 3/4 (19.1) 1/2 1900 (8.5) 3000 (13.3) 2100 (9.3) 4000 (17.8) 380 (1.7) 600 (2.7) 420 (1.9) 800 (3.6) 1. Set depth gauge on drill. 2. Hammer-drill hole. 3. Clean hole. 4. Insert anchor. 5. Insert setting tool and strike with hammer until anchor is fully set. 6. Collar of setting tool will leave an indentation on flange of anchor when properly expanded. HDI-P Anchor Item No. Description Box Qty 00283611 HDI-P 3/8 100 Setting Tools for HDI-P Anchors Item No. Description 00283611 HSD-G 3/8" – 3/4" Setting Tool w/hand guard 00253784 HST-P 3/8" – 3/4" Setting Tool 1 For Hilti matched tolerance carbide tipped drill bits, see section 8.4.1. The Hilti HDI-P Drop-In anchor is an internally threaded, flush mounted expansion anchor for solid and hollow concrete. Product Features • Optimized 3/4" anchor length to allow reliable fastenings in hollow core panels, precast plank & post tensioned slabs • Shallow drilling enables fast installation • Lip provides flush installation, consistent anchor depth and easy rod alignment • Setting tool leaves mark on flange when anchor is set properly to enable inspection & verification of proper expansion Guide Specifications Expansion Anchor Expansion anchors shall be flush or shell type and zinc plated in accordance with ASTM B 633, SC 1, Type III. Anchors shall be Hilti HDI-P anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits. Install anchors in accordance with manufacturer’s recommendations. 4.3.7.2 Material Specifications The HDI-P is manufactured from mild carbon steel, which is zinc plated for corrosion protection in accordance with ASTM B 633, SC 1, Type III HDI-P Drop-In Anchor 4.3.7 Mechanical Anchoring Systems Hilti, Inc. (US) 1-800-879-8000 I Product Technical Guide 2004 I Hilti (Canada) Corporation 1-800-363-4458 185 4.3.7 HDI-P 4.3.7.1 Product Description 4.3.7.2 Material Specifications 4.3.7.3 Technical Data 4.3.7.4 Installation Instructions 4.3.7.5 Ordering Information 4.3.7.1 Product Description HDI-P Specification Table Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com 90 www.tolco.com Revision 5/24/2001 ™® a brand of Fig. 200 -“Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features— • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materials, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/8 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136