HomeMy WebLinkAboutM10-0288� f
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MWO Vy
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
MECHANICAL PERMIT
AMF
Job Address: 483 GORE CREEK DR VAIL
Location.....: TEXAS TOWNHOMES 5B
Parcel No...: 210108274007
OWNER GORDON, LORIE 11/23/2010
7 STERLING AVE
CHERRY HILLS VILLAGE
CO 80113
CONTRACTOR HOME & HEARTH OUTFITTERS
730 S. JASON ST. #28
DENVER
COLORADO 80223
License: 368 -M
11 /23/2010 Phone: (303) 327 -4654
Desciption: INSTALL ONE GAS APPLIANCE FIREPLACE
Valuation: $3,000.00
Permit #: M10 -0288
Project #:
Status ...
Applied ..
Issued . . .
Expires. .:
PRJ 10 -0594
ISSUED
11/23/2010
11/24/2010
05/23/2011
«,.... ������........*........... �*:, �. �... �....... .�..�.. * * * * * * * * * *' * * * * * *""" "'** *FEE S UMMARY """ �...... ��*..., ��,.... �,.,. �... �. ���...... �. �� ........... ...�....,.�� >�..» «.��.. ». « «....
Mechanical Permit Fee --- > $60.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $79.00
Plan Check ------------------- > $15.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00
Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $79.00
Total Calculated Fees - -> $79.00 Payments ----- — ---------- > $79.00
BALANCE DUE --------- > $0.00
APPROVALS
Item: 05100 BUILDING DEPARTMENT
11/23/2010 SBellm Action: AP Per approval of building permit
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01
AM - 4 PM.
Signature of Owner or Contractor
Print Name
</. 4 L
Date
mechca n ica I_perm it_041908
TOWN OF VAIL, COLORADO Statement
Statement Number: R100001909 Amount: $79.00 11/24/201002:45 PM
Payment Method:Credit Crd Init: RFD
Notation: BRIAN
STRICKLAND AUTH031352
-----------------------------------------------------------------------------
Permit No: M10 -0288 Type: MECHANICAL PERMIT
Parcel No: 2101 - 082 - 7400 -7
Site Address: 483 GORE CREEK DR VAIL
Location: TEXAS TOWNHOMES 5B
Total Fees: $79.00
This Payment: $79.00 Total ALL Pmts: $79.00
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
MP 00100003111100 MECHANICAL PERMIT FEES 60.00
PF 00100003112300 PLAN CHECK FEES 15.00
WC 00100003112800 WILL CALL INSPECTION FEE 4.00
04/19/2006 06:58 FAX
Li Complete Mechanical Room Floor Plan with Dimensions
Li Combustion Air Duct Size and Location
❑ Flue detail or Vent size, location & termination
❑ Gas Piping layout including development length calculations
❑ Heat Loss Calculations
Project Street Address:
4 Do i ✓E' > S
(Number) (Street) (Suite #)
BulldinglComplex Name: Tf-A A S 70VzAl 6(or f 6 S
Contractor Information;
Company: fk rw ry �f Z' '�'�/ 6 �'T�/'J
Company Address: E, fl/ANJ
City: t�E7"vrx State: GO zip; f d d a'l o
Contact Name. .FR -IAnr �S'Rz�k =eft nlD
Li Boller size & efficiency
Equipment Cut Sheets for Flreplaces /Log Sets
a 0 01
Manufacturer's Info showing make, model & approval Ilstln
Office Use: /J�y
Project #: A .1�J1c) - () 5qq
Building Permit #: /U 0.3/8 C
Mechanical Permit #: 10 — Oc�C�S[�
Lot #-. Block # Subdivision:
Define Scope and Location of Work: /NS 7—A L[ riNc�
G AS A PP4- , g Al oeC A r F
(use additional sheet If necessary)
❑ Gas Piping Included
Contest Phone' Gas Piping by Others
E -Mail _Z,y /- �� �amc �t�..�/f a� /oli f'ii�r -. s, r; r�00 Wood to Gas Fireplace Conversion
Town of Vail Contractor Registration No.: 3� f3` - /� Boiler Location:
Interior ( ) Exterior ( ) Other ( )
C( ntrac nature (required) Number of Existing Fireplaces:
Gas Appliances Gas Logs I Wood /Pellet
Property Information
Parcel #: Number of Proposed Fireplaces;
(For parcel #, contact Eagle County Assessors Office at 970 -326 -8640 or Gas Appliances i Gas Logs Wood /Pellet
visit www,eaglecounty.us /patle)
Tenant Name:
(Commercial Properties)
Owner Name:
Complete Valuation for Mechanical Permit: (including fireplaces)
Mechanical $: 660
I
1 C:\cdcv \fonns\permils\ building \mechanical _pcnnit_010110
Type of Building:
Single - Family ( ) Duplex ( ) Multi-Family Commercial ( )
Restaurant( ) Other( )
Date Received:
MECHANICAL PERMIT
Boiler / furnace & Fireplace Applications MUST include:
04/19/2006 06:58 FAX
HEARTH
r.I
Town & C ountry 30" Series -C
IICk+Lnp h!u"Inr1
O Q U
I -_
Up W 25 Fte1
O
v
.., %
COMBUBTIBLE FRAMING
AND FINISH WALL ABOVE
STANOOFF9
MAY USE COMBUSTIBLE
FACING MATERIAL IN THIS
AREA
NONCOMBUSTIBLE
nNIi"MAI LRIAL
A
8 C
TOP OF LINTEL BAn
FIREPLACE FRONT. —
NOTE: Fireplace Should be In Its
final location Wore Ireminq.
WINDOW
l'
MAX
HEMTH YnNOOW BUS -FLOOR
EXTENSION TnACK
Whilo a hoorm eelM.len Is MI npulred lop 11116
nwplaw. we Is le64mmeneed lof eYe0u6c
feAeon.. Th. hearm exteralon should De ran.
combucholc end muil MI tv any more Ilan
,. 0.0 the wtlom of IM Moplam. II WiA,.r,
C
1441 . n ' W Seised up aocomnplr.
Caution: Hearth extenalons
thicker then 1" will interfere with
the window frame.
STEEL pRAMING
/ SrANDOFFB
—. :� r/ •' ,
MANTLE CLEARANCE
NON- OOMSWIBLE ZONE.
'f �, .•. •'��
A
X 00 NOT INSTALL ANY
COMBUSTIBLE MATERIAL,
D
12"
r•I, L:C I MCAL WIRING,
'
6
INBULATION, rn.AS K;
�.�•�'.''.•'.'
G"
VAPOUR BARRIER OR
1 1/2"
OAU PLUMBING IN THIS
REf_
MANTLE CLEARANCE
I REF-
MANTLE EXTENSION
A
12"
D
12"
a
g.,
6
B 3/4"
C
G"
F
1 1/2"
I For Technical Questions Please Call 303- 722 -6698
Non - combustible Zone.
Do not Install any
combustible meter
electric wiring,
Insulation, plastic
vapour barrier or
gas plumbing
within the steel
stud frame. 1
28 1,
All other framing
can be done with
conventional lumber
WALL SHIELD
THIMBLE
24" VENT PIPE
ELBOW
12" VENT
PIPE X
141/2" FRAMED
OPENING
'4"
HORIZONTAL
TERMINAL
1F
UZ
w Minimum height from the floor to center of the
opening with a maximum horizontal run of 34 5/16"
using a 24" pipe. The height will need to be Increased
with a longer horizontal run.
Gas and electrical need to be brought to the
same location. The right side of the firebox
has a control box mounted on the side of the
unit. Also, your plumber needs to install an
accessible gas shut off key valve. The
electrical needs to be un- switched continuous
11 0v.
04/19/2006 06:58 FAX
TOWN &COUNTRY
L U X U R Y ;I R E P L A C E S
SECTION 10305
MANUFACTURED GAS FIREPLACES
PART
1
GENERAL
1.1
SECTION
INCLUDES
A.
Modular luxury direct -vent gas fireplaces, vented to the exterior.
1.2
RELATED
SECTIONS
A.
Section 15145 - Plumbing Piping: Gas piping and shut -off valve.
1.3
REFERENCES
A.
ANSI Z223.1 - National Fuel Gas Code.
B.
CAN /GSA 8149.1 - Natural Gas and Propane Installation Code
C.
CSA 2.22 - Vented Gas Fireplaces
D.
CAN /CGA 2.17 - M91 Gas -fired Appliance for Use at High Altitudes
1.4
SUBMITTALS
A.
Submit under provisions of Section 01300,
B.
Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
3. Installation methods.
1.5
QUALITY ASSURANCE
A,
Manufacturer Qualifications:
1. Manufacturer of fireplaces and stoves continuously for over 30 years.
B.
Installer Qualifications:
1. Licensed as required by local codes.
2. National Fireplace Institute certified installers required.
3. Factory- trained installers from authorized dealers required.
C.
Multiple Installation Mock -Up: Provide a mock -up for evaluation of site and framing
preparation techniques and installation workmanship.
1. Provide representative fireplace In area designated by Architect.
2. Do not proceed with remaining units until workmanship, installation and
operation are approved by Architect.
0 003
10305 -1
04/19/2006 06:58 FAX
3. Remake mock -up unit as required to produce acceptable work.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Store products in manufacturer's unopened packaging until ready for installation.
B. Packaging includes large premium ceramic glass door. Handle with care.
1.7 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within
limits recommended by manufacturer for optimum results. Do not install products
under environmental conditions outside manufacturer's absolute limits.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Town & Country Fireplaces Ltd.; 2975 Allenby Rd.,
Duncan, BC, Canada V9L 6V8. ASD. Toll Free Tel: (888) 223 -0088. Fax: (250)
748 -0844. Email: sales(a Web:
http: / /www_ town andcountryfireplaces, net
2.2 GAS FIREPLACES, DECORATIVE DIRECT VENT
A. Provide fireplace housing, interior panels, burner, venting, controls and accessories
as required for complete installation. Installation shall include the following;
1. Framing: Provide factory framing kit of non combustible material engineered
to maintain required clearances, and support finished surround materials,
2. Facade: Provide clean face style, no louvers, flush hearth capability and
premium ceramic glass
3, Gas valve control: Provide wall mounted control system and hand held
programmable remote. Maestro Control System as supplied by Town &
Country Fireplaces Ltd.
4. Ignition System: Provide electronic ignition, with standing pilot capacity and
battery back -up
5. Heat Control Safety; Provide thermostat lock -out (as required by local codes)
and child lock -out
6. Aesthetic design: Provide interchangeable interior panels and burners.
Design -A -Fire as supplied by Town & Country Fireplaces, Ltd
7_ Provide gas conversion kit: natural gas to propane
B. Direct Vent Gas Fireplace: Town & Country TC30 DDV Luxury Gas Fireplace:
Front View, Ceramic Glass, no louvers, interchangeable interior panels and burners,
glowing embers, Finishing Touch Trim Kit, Maestro wall and programmable
handheld controls:
1. Model: Town & Country TC30 Luxury DDV Fireplace.
2. Burner: Maximum BTU input - 35,000. Minimum BTU input - 27,000.
3. Firebox Liner: Beige Herringbone Panels.
PART 3 EXECUTION
3.1 EXAMINATION
A. Do not begin installation until site has been properly prepared.
B. If location preparation is the responsibility of another installer, notify Architect of
unsatisfactory preparation before proceeding.
Z004
10305 -2
04/19/2006 06:58 FAX
3.2 PREPARATION
A. Clean surfaces thoroughly prior to installation.
B. Prepare opening and supporting surfaces to comply with local codes and
manufacturer's requirements to maintain approved construction rated classification.
C. Verify proper power supply and fuel source are available.
3.3 INSTALLATION
A. Install in accordance with manufacturer's instructions, and the requirements of
authorities having jurisdiction, as approved by the Architect.
B, Use manufacturer's fireplace and venting guidelines for minimum clearances to
combustibles, walls, and finishes.
C. Upon completion of installation, visually Inspect all exposed surfaces. Touch up
scratches and abrasions with touch -up paint recommended by the manufacturer,
make imperfections invisible to the unaided eye from a distance of 5 feet (1.5 m).
D. Test for proper operation.
E. Complete Installer's Warranty Validation Card
3.4 PROTECTION
A. Protect installed products, especially fireplace glass, until completion of project.
B. Touch -up, repair or replace damaged products before Substantial Completion.
END OF SECTION
Q 005
10305 -3
M Type: B-MECH Vers: 2007 MECHANICAL PERMIT Sub-Type- AMF (Activity)
Permit N: IM10.0288 Address: 1483 GORE CREEK DR VAIL
Status: IFINAL OWNER: IGORDON, LORIE
Date: F1-1/23/2010
IM
icreeni
ED
Fees
A
I
9XK
I Deslj�
A
Cand
I LIHIN
HPIn
Pe le
"Jowc
Relate
LINK
Doc
Action
. . ... ...... ....
Inspection Items for M10-0288
Inspections I Guide Sheet
See
Item Id
Description
Appi
Req
items
Action
I
200
M E CH -R ough
Yes
10
i 1
1 AP
310
MECH-Heating
h4•6as PignQ
MECH-Exhaust Hoods
No
0
0
315
320
No
No
0
0
0
0
330
MECH-Supply Air
No
0
0
340
No
0
0
Backkop
K=-7
Add
Item
Insert
Item
Remov
Item
F Display Updateable Items Only
Pnnt
Entries for Item:390 MECH-Final
Action I Comments I By i Date I imm Kel
LLJ 11
Action: AP By Martin Date:
Begin Time: End Time: "ii OR Elapsed Time:
Start Miles: EndlVliiles:[0.110 OR Total Mileagef 0.00
Vehicle Id: Violations:
Select
Comment
6w
Entry
Updal:
Entry
Delete
E ntry
Refresh
e5
Entered Date: Entered By: MHAEBERLE pt
Toolbar Order Select Select muitii* r-
Multiple
ho
for Insp
liN Document Doc I Back] 1Er:itd