Loading...
HomeMy WebLinkAboutB10-0425NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES WO Vv Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD /ALT MF BUILD PERMIT Permit #: B10 -0425 Job Address: 4507 MEADOW DR VAIL Location......: SUNWOOD CONDOS, UNIT A -1 Parcel No....: 210112425001 OWNER AHBE, NINA B. - SIPAL, CAROL 11/26/2010 KATHERINE S. KODIAK TRUST- KOZMIN, JULIA 6331 S GENEVA CIR ENGLEWOOD CO 80111 -5437 ARCHITECT TRD ARCHITECTS 11/26/2010 Phone: 970 - 479 -7387 TOM DUBOIS PO BOX 1492 VAIL CO 81658 License: 0000001769 APPLICANT W.B. MONTAG /HOME IMPROVEMENT 11/26/2010 Phone: 970 - 748 -7394 P.O. BOX 3534 VAIL CO 81658 License: 196 -B CONTRACTOR W.B. MONTAG /HOME IMPROVEMENT 11/26/2010 Phone: 970 - 748 -7394 P.O. BOX 3534 VAIL CO 81658 License: 196 -B Description: FULL INTERIOR REMODEL: KITCHEN, DINING, HALL, TV ROOM, BATHROOMS, BEDROOMS Project #: Status .. : Applied. Issued ... Expires ...: PRJ10 -0782 ISSUED 11/26/2010 12/14/2010 06/12/2011 Occupancy: Valuation: $49,000.00 Type Construction: Total Sq Ft Added: 0 ...,.. . FEE SUMMARY ................� ....., .,� .......� >..�..,,, .....�..............��....... Building Permit Fee ------ > $633.65 Will Cal Fee --------------------- > $4.00 Total Calculated Fees ------------- > $1,829.52 Plan Check--------------- - - - - -> $411.87 Use Tax Fee --------------------- > $780.00 Additional Fees ---------- — ----------- > $0.00 Add'[ Plan Check Hours -> $0.00 Restuarant Plan Review - - - - -> $0.00 TOTAL PERMIT FEES -- ----------- > $1,829.52 Investigation------------ - - - - -> $0.00 Recreation Fee------------ - - - - -> $0.00 Payments -- ---------------------------- > $1,829.52 Total Calculated Fees--- - - - - -> $1,829.52 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the informatior as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 Ppe Signature of Owner ontractor Date Print Name b Id —a It —co n st ru cti o n_pe rm it_041908 APPROVALS Permit #: B10 -0425 as of 12 -14 -2010 Status: ISSUED Item: 05100 BUILDING DEPARTMENT 12/14/2010 martin Action: AP Item: 05110 ELECTRICAL REVIEW 12/14/201.0 martin Action: AP Item: 05120 MECHANICAL REVIEW 12/14/2010 martin Action: AP Item: 05130 PLUMBING REVIEW 12/14/2010 martin Action: AP Item: 05600 FIRE DEPARTMENT 12/07/2010 mvaughan Action: AP See the Conditions section of this Document for any that may apply. b Id_a It_co nstruction_perm it_041908 CONDITIONS OF APPROVAL Permit #: B10 -0425 as of 12 -14 -2010 Status: ISSUED Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. bid_a It_co nstruction_pe rm it_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R100002009 Amount: $1,829.52 12/14/201011:37 AM Payment Method: Check Init: LC Notation: #2476 / WB MONTAG HOME IMPROVEMENT ----------------------------------------------------------------------------- Permit No: B10 -0425 Type: ADD /ALT MF BUILD PERMIT Parcel No: 2101 -124- 2500 -1 Site Address: 4507 MEADOW DR VAIL Location: SUNWOOD CONDOS, UNIT A -1 Total Fees: $1,829.52 This Payment: $1,829.52 Total ALL Pmts: $1,829.52 Balance: $0.00 ACCOUNT ITEM LIST: Account Code -------------- Description Current Pmts BP - - - - -- 00100003111100 ------------------------ - - - - -- BUILDING PERMIT FEES ------ - - - - -- 633.65 PF 00100003112300 PLAN CHECK FEES 411.87 UT 11000003106000 USE TAX 4% 780.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 Project S�tlreet Address: Office Use: Q� Z ct� ��_ Project #: (Number) (Street) (Suite #) DRB #: Building/Complex Name: JJ`. V00 ,9& Building Permit # I/D • 0245 Contractor, Information- Company: w • 3.A, —� 1 11a�, tV,rx1�•N�+l Company address: City: \ � 0 State: Tip. l Contact Nam: Contact Phone: E-Mail Town of Vail Contractor Registration No.: ` 0((o Q X�� Contractor Signature (required) Lot #: Block # Subdivision: Detailed Description of Work: r�Jf (use additional sheet if necessary) I Work Class: New ( ) Addition ( ) Remodel ()0 Repair ( ) Other ( ) Work Type Interior ()<) Exterior( ) Both( ) Property Information Type of Building: Parcel # 1 ` 0 \ kg�-L 2s,d Single- Family ( ) Duplex ( ) Muni- Family (�) (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or i visit www.eagleoounty.us/patie) i Commercial( ) Other( ) Tenant Name: Owner Name: JQ- I & kikst Valuations (Labor & MateriaD) Building: $ l Lx� Plumbing: $ Electrical: $ • Uo Mechanical: $ Q — Total: $ Cl ( c ) c :kdcWOrm *- Iitslbui ldinglcomm_lwildingjermit loolo9 Does a Fire Alarm Exist? Yes ( ) No P<) Monitored Alarm? Yes ( i No (7Cj Does a Sprinkler System Exist? Yes ( ) No (� # & Type of Existing Fireplaces: Gas Appliances Gas Log Wood/Pellet Wood Burning 4- # & Type of Proposed Fireplaces: Gas Appliances Gas Log Wood/Pellet Wood Burning _ Date Receiv °,, NOV 2 3 2010 u F VAIL 01 -OU-09 PROJECT OUTLINE Renovate /remodel condominium as follows; Remove and dispose of all existing construction debris currently in condominium and on condominium back deck. All -new prehung doors /doorjambs, bifold doors /doorjambs /headers, base trim, and door /window casing will be finished using two coats clear, water -based polyurethane with a satin finish. All new file and grout will be sealed using standard matte finish sealer. Install new white colored thermostats for baseboard heaters replacing existing baseboard heater thermostats. Install new white colored, Decora style switches and receptacles /switch covers receptacle covers throughout the condominium; 24 duplex receptacles, 12 single poll switches, 6, 3-way switches, 5 single pole dimmer switches. Kitchen /Dir ft room /Fireplace room: Remove and dispose of existing kitchen lighting. Install 6 new standard 6" can rights in ceiling. Can lights will have standard white trims. Can fights will have 75 watt halogen right bulbs. Remove and dispose of existing non - bearing kitchen "post" and rewire existing electrical switches, electric receptacle, and phone line. Phone line will be rewired and located above the kitchen counter near dining room window. Light switches will be rewired and located near electrical breaker box. Electric receptacle will be rewired and located in the side of the kitchen island base cabinets. A second electrical receptacle will be wired on the opposite side of the kitchen island base cabinets using the some electrical circuit. Move existing electric range 240 volt circuit from current location to new location in kitchen island to allow for electric range installation. Install 2 new GFI protected electrical receptacles above kitchen countertop. Install new standard 120 volt under cabinet heater under kitchen sink cabinet. Install power source and switchbox for the in floor heat system with a new 240 volt GFI breaker. Remove any existing floor file and prep floor for new file installation. Install in floor heating system with seven day programmable thermostat. Thermostat will be installed near kitchen cabinets /dining room window. Heating system /file will be installed on the entire floor area from main exterior entrance, to doorway into TV room, approximately 260 ff2. Install Ditra- Schlueter anti - fracture system over new in floor heating system. Install approximately 260 ft .2 of 16 x 16 slate tiles on anti - fracture membrane using standard thinset. Seal all 16 x 16 slate tiles using standard matte finish sealer. Install standard sanded grout in all newly created grout joints. Size of grout joints yet to be determined. Grout color yet to be determined. Install backsplash file above kitchen countertops /below kitchen cabinets using standard wall tile mastic. Size and type of file and grout joints yet to be determined. Install standard grout in all newly created grout joints. Size of grout joints yet to be determined. Grout type and color yet to be determined. Remove and save for reinstallation dining room chandelier and the main entryway wall fight. Remove all popcorn texture from ceiling. Replace any missing drywall on walls and ceilings. Patch any drywall where removed for new electrical installation. Finish all new drywall to be flat and smooth. Prep walls for new texture. Apply a medium skip trowel texture to all walls and ceilings. Apply one coat of drywall primer to all new drywall. Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all ceilings. Paint Sheen will be flat. Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all walls. Sheen will be eggshell. Install new kitchen cabinets. Install kitchen cabinet crown molding /trim. Install new cabinet /drawer pulls /handles. Oversee new granite countertops /sink installation. Install new kitchen faucet, new kitchen drain hardware, new kitchen dispose all using steel braided water supply lines and plastic drain piping. Install existing refrigerator, new electric range, and new dishwasher with steel braided water supply line. Apply one coat of Uz2 stain Mocker /primer to 2' x 8' sub floor area in front of sliding door. Approximately 16 ft?. Install 9/16" x 5" #412 Austin Victorian K. knotty alder base trim where needed. Install 5/8" x 3" #332 Austin /Victorian K. knotty alder casing around dining room windows. Reinstall dining room chandelier and the main entryway wall light. TV roam: Cap wet bar plumbing inside of wall. Remove existing dangling wet bar wires. Move existing dangling electrical receptacle to new location in wet bar area. Receptacle location yet to be determined. Install 2 new standard 6" can lights with wall light switch in ceiling of wet bar area. Light switch location yet to be determined. Install 2 new standard 6" can lights with wall light switch in ceiling of TV room area. Light switch location yet to be determined. Install 2 x 4 framing where needed in a bar area to allow for drywall installation. Prep walls for new texture. Remove all popcom texture from ceiling. Replace any missing drywall on walls and ceiling. Install square drywall comer bead where needed in wet bar area. Patch any drywall where removed for plumbing work /new electrical installation. Finish all new drywall to be flat and smooth. Apply a medium skip trowel texture to all walls and ceiling. Apply one coat of drywall primer to all new drywall. Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all ceilings. Paint Sheen will be flat. Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all walls. Sheen will be eggshell. Install new 8'and 6' electric baseboard heaters using existing electric heater circuits. Heater cover color will be Navajo white Apply one coat of Kltz2 stain blocker /primer to 2' x 8' sub floor area in front of sliding door. Approximately 16 ft?. Install 9/16" x 5" #412 Austin Victorian K. knotty alder base trim where needed. Hallway: Remove wall light fixture and save for reinstallation. Remove all popcorn texture from ceiling. Replace any missing drywall on walls and ceiling. Install square metal corner bead where needed. Finish all new drywall to be flat and smooth. Apply a medium skip trowel texture to all walls and ceilings. Apply one coat of drywall primer to all new drywall. Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all ceilings. Paint Sheen will be flat. Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all walls. Sheen will be eggshell. Reinstall wall fight fixture. Install Knotty Alder, 2 panel, Flat panel, Square top, V Groove, 24" bifold door in hall closet door opening using Johnson hardware. Install 9/16" x 5" #412 Austin Victorian K. knotty alder base trim where needed. Install 5/8" x 3" #332 Austin Victorian K. knotty alder casing around prehung doorframes. Halway Bathroom: Replace existing shower control and showerhead with new shower control and showerhead. Install framing for shower bench using 2 x 4 pressure - treated lumber. Install new concrete shower pan using steel mesh reinforcement, standard concrete shower pan drain hardware, and PVC shower pan drain liner. Install 4 mill plastic vapor barrier around /on shower area framing. Install %" cement board on walls and bench of shower area framing using 15/8" zinc coated screws. Install 12 x 12 porcelain tiles on the walls and bench with a 4 x 12 listelle on the walls, using standard thinset. Size of grout joints yet to be determined. Install pebble files on 12 x 12 mesh backing on shower floor using standard thinset. Install grout in all newly created grout joints. Type of gout yet to be determined. Color of gout yet to be determined. Install standard glass shower enclosure /shower door. Install new vanity. Install new cabinet /drawer pulls /handles. Oversee granite countertop /sinks installation. Install chrome colored water shutoff valves for vanity sinks and toilet. Install new faucets /drain hardware using new steel braided supply lines. Install new 2' electric baseboard heater using existing electric heater circuit. Heater cover color will be Navajo white. Install Knotty Alder, 2 panel, Flat panel, Square top, V Groove, bifold door in water heater closet opening using Johnson hardware. Install new Knotty Alder, 2 panel, Rat panel, Square top, V Groove with oil rubbed bronze hinges, 30" right -hand prehung toilet room door with lock set /handle set /latch plate. Install new Knotty Alder, 2 panel, Hat panel, Square top, V Groove with oil rubbed bronze hinges, 30" right -hand prehung hallway entrance door with lock set /handle set /latch plate. Remove all popcorn texture from ceiling. Replace any missing drywall on walls and ceiling. Finish all new drywall to be flat and smooth. Apply a medium skip trowel texture to all walls and ceilings. Apply one coat of drywall primer to all new drywall. Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all ceilings. Paint Sheen will be flat. Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all walls. Sheen will be eggshell. Install 2 new vanity light fixtures. Install 5/8" x 3" #332 Austin Victorian K. knotty alder casing around alder doorframes. Master Bathroom: Replace existing exhaust fan with new Panasonic quiet exhaust fan. Replace existing shower control and showerhead with new shower control and showerhead. Install new bathtub. Install 4 mill plastic vapor barrier around /on tub /shower area framing. Install 1/2" cement board on walls of shower area framing using 1 5/8" zinc coated screws to allow for the installation. Install 12 x 12 tiles on the walls of tub /shower area, with a 4 x 12 listelle on the walls, using standard thinset. Size of grout joints yet to be determined. Install standard grout in all newly created grout joints. Type of grout yet to be determined. Color of grout yet to be determined. Install 120 V power supply with switch box and new GFI protected breaker for in floor heating system. Install floor heating system using seven day programmable thermostat. Install Ntra- Schlueter anti- fracture system over new in floor heating system. Install 16 x 16 slate files using standard thinset. Approximately 35 ft .2. Size of grout joints yet to be determined. Seal slate tiles using standard matte finish sealer. Install standard sanded grout in all newly created grout joints. Grout color yet to be determined. Install new vanity. Install new cabinet /drawer pulls /handles. Oversee granite countertop /sink installation. Install new chrome colored water shutoff valves for vanity sink and toilet. Install new faucet /drain hardware using new steel braided supply lines. Install Knotty Alder, 2 panel, Flat panel, Square top, V Groove, 30" bifold door in linen closet opening using Johnson hardware. Install new Knotty Alder, 2 panel, Fiat panel, Square top, V Groove with oil rubbed bronze hinges, 36" right -hand prehung hallway entrance door with lock set /handle set /latch plate. Remove all popcom texture from ceiling. Replace any missing drywall on walls and ceiling. Finish all new drywall to be flat and smooth. Apply a medium skip trowel texture to all walls and ceilings. Install existing mirror above vanity. Install new vanity fight fixture. Install new toilet using wax ring and new wire mesh supply line. Apply one coat of drywall primer to all new drywall. Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all ceilings. Point Sheen will be flat. Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all walls. Sheen will be eggshell. Install 5/8" x 3" #332 Austin Victorian K. knotty alder casing around alder doorframes. Master Bedroom: ceiling. Install switch and new power to new ceiling light junction box located in the center of Remove and dispose of existing carpet and carpet padding. Remove and dispose of existing closet doors, closet doorjambs /header, door and window trim. Remove all popcom texture from ceiling. Apply a medium skip trowel texture to all walls and ceilings. Apply one coat of drywall primer to all new drywall. Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all ceilings. Paint Sheen will be flat. Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all walls. Sheen will be eggshell. Install Knotty Alder, 2 panel, Rat panel, Square top, V Groove with oil rubbed bronze hinges, 30" right -hand prehung door with lock set /handle set /latch plate. Install new knotty alder closet door jambs /header. Install 2, Knotty Alder, 2 panel, Rat panel, Square top, V Groove, 36 inch doors with bypass hardware in closet door opening. Install new 4'and 3' electric baseboard heaters using existing electric heater circuits. Heater cover color will be Navajo white. Install 9/16" x 5" #412 Austin /Victorian K. knotty alder base trim where needed. Install 5/8" x 3" #332 Austin /Victorian K. knotty alder casing around alder doorframes and window where needed. Install new cei ing fight fixture. 2nd Bedroom: Install switch and new power to new ceiling light junction box located in the center of ceiling. Remove and dispose of existing carpet and carpet padding Remove and dispose of existing closet doors, closet doorjambs /header, door and window trim. Remove all popcom texture from ceiling. Apply a medium skip trowel texture to all walls and ceilings. Apply one coat of drywall primer to all new drywall. Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all ceilings. Paint Sheen will be flat. Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all walls. Sheen will be eggshell. Install Knotty Alder, 2 panel, Hat panel, Square top, V Groove with oil rubbed bronze hinges, 30" left -hand prehung knotty alder door with lock set /handle set /latch plate. Install new knotty alder closet door jambs /header. Install 2, Knotty Alder, 2 panel, Rat panel, Square top, V Groove, 36 inch doors with bypass hardware in closet door opening. Install new 4'and 3' electric baseboard heaters using existing electric heater circuits. Heater cover color will be Navajo white. Install 9/16" x 5" #412 Austin Victorian K. knotty alder base trim where needed. Install 5/8" x 3" #332 Austin /Victorian K. knotty alder casing around alder doorframes and window where needed. Install new ceding fight fixture. V Asbestos Inspection and Sampling Report Sunwood Condos 4594 Meadow Dr. UnitA -1, Vail, Colorado 81657 Presented to: Mr. Jon Greener Ridgeline Builders PO Box 3314 Vail, CO 81620 (970) 331 -9990 Performed & Prepared by: Mr. Nate Skinner DS Consulting, Inc. PO Box 6864 Avon, CO 81620 (303) 917 -8081 Project Details: DSC Project #: 2656 Conducted: August 18, 2010 Consulting OP , EXECUTIVE SUMMARY On August 18, 2010, Mr. Nate Skinner of DS Consulting, Inc. (DSC) performed a limited inspection and asbestos bulk - sampling at Sunwood Condos 4594 Meadow Dr. Unit A -1, Vail, Colorado, in order to identify potentially hazardous friable and non - friable asbestos - containing materials (ACM) within the above - referenced, single family residence where renovations activities are planned. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos - containing material (ACM) as a material containing more than 1% asbestos. Mr. Skinner performed asbestos bulk - sampling of drywall (surfacing material) in a total of six (6) locations within the residence (see Appendix A for sample locations). All six (6) bulk - samples were analyzed by Aerobiology Laboratory Associates, Inc. (NVLAP #200860 -0) with all six (6) laboratory results reporting as negative for asbestos (see Appendix C for laboratory results). 2 PROJECT OVERVIEW I. Introduction A limited inspection and bulk - sampling for ACM was conducted at Sunwood Condos 4594 Meadow Dr. Unit A -1, Vail, Colorado, by Mr. Skinner on August 18, 2010, at the request of Mr. Jon Greener with Ridgeline Builders. Mr. Skinner is a Colorado State Certified Building Inspector; having EPA Accreditation #16227 (see Appendix B for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non - friable ACM within the residence. II. Structural Design The structure is a single -level unit, in a multi -unit complex. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk - sampling techniques. The asbestos bulk- sampling was conducted on suspect ACM with a limited number of bulk - samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency / AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk - samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk - samples, representative of the suspect asbestos - containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA),15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un- sampled material. Bulk- samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk - samples was performed on the "date reported," as listed in the bulk - sample analysis report. r IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing Material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl /linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water - stained, gouged, marred or otherwise abraded over less than one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: • The surface is crumbling or blistered over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). • One -tenth (one - quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. • Water stains, gouges, or mars are over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response- action recommendations for asbestos - containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1% within the bulk- sample, or a bulk - sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1% within the bulk - sample, or a bulk - sample in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1% unless it is analyzed by the point -count method to be less than 1 %. V. Inspector Comments No asbestos - containing material (ACM) was identified during the bulk - sampling conducted at Sunwood Condos 4594 Meadow Dr. Unit A -1, Vail, Colorado. A total of six (6) bulk - samples were collected from drywall within the above - referenced residence. All six (6) bulk- samples tested negative for asbestos. 4 VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent - asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at Sunwood Condos 4594 Meadow Dr. Unit A -1, Vail, Colorado, on August 18, 2010. The quantities are approximations and are subject to field verification: Homogeneous Area #01 Sample #: DC1 -1 Homogeneous Area #01 Sample #: DC1 -2 Sample Description: Drywall Sample Description: Drywall Sample Location: Living Room Ceiling Sample Location: Hallway Ceiling Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity. +/- 900ft2 Material Quantity: +/- 900ft2 Material Condition: Good Material Condition: Good Physical Description (layers): White texture; White foamy texture; White compound; White /tan drywall physical Description (layers): White foamy texture w/ tan paint; White /tan drywall Asbestos Detected (layers): Negative; Negative; Negative; Negative Asbestos Detected (layers): Negative; Negative Recommendations: GENERAL - See Section VII Recommendations. GENERAL - See Section VII Homogeneous Area #0 1 Sample #: DC1 -3 Homogeneous Area #02 Sample #: DW1 -1 Sample Description: Drywall Sample Description: Drywall Sample Location: Bedroom 1 Ceiling Sample Location: Living Room Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity. +/- 900ft2 Material Quantity. +/- 900ft2 Material Condition: Good Material Condition: Good Physical Description (layers): White compound; White texture w/ white paint; White /tan drywall Physical Description (layers): White tape; White joint compound; White texture w/ cream paint; Gra tan drywall Asbestos Detected (layers): Negative; Negative; Negative; Negative Asbestos Detected (layers): Negative; Negative; Negative; Negative Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII 5 Homogeneous Area #02 Sample #: DWI-2 Homogeneous Area #02 Sample #: DW1 -3 Sample Description: Drywall Sample Description: Drywall Sample Location: Hallway Wall Sample Location: Bedroom 1 Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity. +/- 900ft2 Material Quantity: +/- 900ft2 Material Condition: Good Material Condition: Good Physical Description (layers): White tape; White joint compound; White compound w/ white paint; White compound w/ cream paint; Gray /tan d all physical Description (layers): White tape; White joint compound; White texture w/ white paint; Gray /tan drywall Asbestos Detected (layers): Negative; Negative; Negative; Negative Asbestos Detected (layers): Negative; Negative; Negative; Negative Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII VII. Recommendations GENERAL: The laboratory results of the potential ACM sampled at Sunwood Condos 4594 Meadow Dr. Unit A -1, Vail, Colorado, indicate that all six (6) bulk - samples of drywall collected were reported as negative for asbestos. Therefore, no professional abatement activities are recommended to remove the above - referenced material. I APPENDIX A SAMPLE LOCATIONS APPENDIX B CERTIFICATION STATE OF COLORADO ASBESTOS CERTIFICATION* Colorado Department of Public Health and Environment Air Pollution Control Division This certifies that Nathan Skinner Certification No: 16227 has met the requirements of 25 -7 -507, C.R.S. and Air Quality Control Commission Regulation No. 8, Part B, and is hereby certified by the state of Colorado in the following discipline: Building Inspector* Issued: 2/6/2010 Expires on: 2/6/2011 ' This crrrifirare is wAd wwfp Y'&k 66c pwnminw wja tvrrrwr DYrisiaw- app+wvrd rraiwiap copra c ulian in 1k, dh *,—spr feed ab- APPENDIX C LABORATORY ANALYSIS ` kt AERUDIULOt1y LADORATORY ASSOCIATES, INCORPORATED X� CONSULTING LABORATORY 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 Certificate of Analysis www.aerobiolony.net Client Name Street address DS Consluting, Inc. 5366 Flatrock Ct. Minn n� Date Collected: 08/18/10 Number of La ers % W `/ ISLrJ Date Received: 08 /18 /10 City, State ZIP Morrison, CO 80465 Date Analyzed: 08/18/10 Attn: Nate Skinner #200860 -0 Date Reported: 08/18/10 Client Project Name: Sunwood Condos Unit A8 Vail Project ID: 105881 4,5% Job ID: CHRY= Chrysotile Test Requested: 3002, Asbestos in Bulk Samples 105881 -1B Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA -600/R- 93/116. July 1993. 4,10% Sample Identification Physical Description of Sample; Additional Comments Homo- geneous es /no Number of La ers % Asbestos Detected Non - Asbestos Fibers area % Non - Fibrous Material area % Matrix Material (composition) MW = Mineral Wool Client Lab Sample Number DC1 -1 1058814A White Texture N 4,5% Negative CHRY= Chrysotile 100 C,M 105881 -1B White Foamy Texture N 4,10% Negative Adam Humphreys 100 C,M 105881 -1C White Compound N 4,15% Negative NAC = Non- Asbestiform AC 100 G 105881 -1D White /Tan Drywall N 4,70% Negative 30% CELL 70 G DC 1 -2 105881 -2A White Foamy Texture w/ Tan Paint N 2,15% Negative 100 C,M 105881 -2B White/Tan Drywall N 2,85% Negative 30% CELL 70 G DCl -3 105881 -3A White Compound N 3,5% Negative 100 G,M 105881 -313 White Texture w/ White Paint N 3,15% Negative 100 C,M 105881 -3C White/Tan Drywall N 3,80% Negative 30% CELL 70 G DW24 1058814A White Tape N 4,10% Negative 97% CELL 3 B A = Amosite CELL = Cellulose Q = Quartz f AC = Actinolite MW = Mineral Wool C = Carbonates / % b - — ` —` - , _ _ _ . AN = Anthophyllite FBG = Fiberglass V = Vermiculite CHRY= Chrysotile SYN = Synthetic G = Gypsum CR = Crocidolite WO = Wollastonite M = Mica Adam Humphreys Adam Humphreys TR = Tremolite NTR = Non- Asbestiform TR T = Tar Laboratory Analyst Asbestos Laboratory Supervisor Trace =Less Than 1% NAC = Non- Asbestiform AC P = Perlite FT = Fibrous Talc O = Organic AH = Animal Hair B = Binder OP = Opaques \_ AERODIULUCiy LADORATORY 1'1 ASSOCIATES, INCORPORATED �\ CONSULTING LABORATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205' Lakewood, CO 80401 303.232.3746 www.aerobiology.net Client Name Street address DS Consluting, Inc. 5366 Flatrock Ct. Date Collected: 08/18/10 Asbestos Detected Non - Asbestos Fibers area % ���� Date Received: 08/18/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 08/18/10 Attn: Nate Skinncr #200860 -0 Date Reported: 08/18/10 Client Project Name: Sumvood Condos Unit A8 Vail Project ID: 105881 1058814C White Texture w/ Cream Paint Job ID: 4,25% Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993. Sample Identification Physical Description of Sample; Additional Comments Homo- geneous es /no Number of La ers % Asbestos Detected Non - Asbestos Fibers area % Non - Fibrous Material area % Matrix Material (composition) V = Vermiculite Client Lab Sample Number DW24 105881 -413 White Joint Compound N 4,25% Negative T = Tar 100 G,M 1058814C White Texture w/ Cream Paint N 4,25% Negative AH =Animal Hair 100 C,M 1058814D Gray /Tan Drywall N 4,40% Negative 35% CELL 65 G DW2 -2 105881 -5A White Tape N 5,10% Negative 97% CELL 3 B 105881 -513 White Joint Compound N 5,15% Negative 100 G,M 105881 -5C White Compound w/ White Paint N 5,20% Negative 100 C M 105881 -51) White Compound w/ Cream Paint N 5,20% Negative 100 C,M 105881 -5E Gray/Tan Drywall N 5,35% Negative 50% CELL 50 G DW2 -3 105881 -6A White Tape N 4,10% Negative 97% CELL 3 B 105881 -6B White Joint Compound N 4,15% Negative 100 G,M A = Amosite CELL = Cellulose Q = Quartz AC = Actinolite MW = Mineral Wool C = Carbonates AN = Anthophyllite FBG = Fiberglass V = Vermiculite -' ✓` "" - CHRY= Chrysotile SYN = Synthetic G = Gypsum CR = Crocidolite WO = Wollastonite M = Mica TR = Tremolite Adam Humphreys Adam Humphreys NTR = Non - Asbestiform TR T = Tar Trace =Less Than I% Laboratory Analyst Asbestos Laboratory Supervisor NAC = Non - Asbestiform AC P = Perlite FT = Fibrous Talc O = Organic AH =Animal Hair B = Binder _ OP = Opaques `k AEROD1010(.iy LADORATORy —.—� ASSOCIATES, INCORPORATED CONSULTING LABORATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerobioloay.net Client Name Street address DS Consluting, Inc. 5366 Flatrock Ct. Date Collected: 08/18/10 Asbestos Detected Non - Asbestos Fibers area % KWR,� Date Received: 08/18/10 City, State ZIP Morrison. CO 80465 Date Analyzed: 08/18/10 Ann: Nate Skinner #200860 -0 Date Reported: 08/18/10 Client Project Name: Sunwood Condos Unit A8 Vail Project ID: 105881 105881 -613 Gray /Tan Drywall Job ID: 4,60% Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993. Sample Identification Physical Description of Sample; Additional Comments Homo- geneous es /no Number of La ers % Asbestos Detected Non - Asbestos Fibers area % Non- Fibrous Material area % Matrix Material (composition) V = Vermiculite Client Lab Sample Number DW2 -3 105881 -6C White Texture w/ White Paint N 4,15% Negative T = Tar 100 C,M 105881 -613 Gray /Tan Drywall N 4,60% Negative 40% CELL 60 G OP ^Opaques Adam Humphreys Laboratory Analyst Haam rtumpnreys Asbestos Laboratory Supervisor A = Amosite CELL = Cellulose Q = Quartz AC = Actinolite MW = Mineral Wool C = Carbonates AN = Anthophyllite FBG = Fiberglass V = Vermiculite CHRY= Chrysotile SYN = Synthetic G = Gypsum CR = Crocidolite WO = Wollastonite M = Mica TR = Tremolite NTR = Non - Asbestiform TR T = Tar Trace =Less Than 1% NAC = Non - Asbestiform AC P = Perlite FT = Fibrous Talc O = Organic AH =Animal Hair B = Binder OP ^Opaques AERObiolocjy LAbORATORy 13949 W. Colfax Ave ASSOCIATES, INCORPORATED Suite 205 Lakewood, CO 80401 CONSULTING LABORATORY 303.232.3746 Certificate of Analysis www.aerobiolo_q net DS Consluting, Inc. 5366 Flatrock Ct. Date Collected: 08/18/10 Morrison, CO 80465 MWa ? Date Received: Date Analyzed: 08/18/10 08 /I8 /10 Nate Skinner #200860 -0 Date Reported: 08/18/10 Client Project Name: Sunwood Condos Unit A8 Vail Project ID: 105881 Job ID: General Notes ♦ Negative indicates no asbestos was detected; the method detection limit is 1 %. ♦ Trace or " <1" indicates asbestos was identified in the sample, but the concentration is less than the method detection limit of 1 %. ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the asbestiform variety of the mineral reibekite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi - quantitative bulk TEM floor tile analysis is accepted under the NESHAPS regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples. Notes Required by NVLAP ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP- approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 03 -01 -2011 Inspection Request Reporting Page 6 4:12 pm Vail, CO - City 0 Requested Inspect Date: Wednesday, March 02, 2011 Inspection Area: JRM Site Address: 4507 MEADOW DR VAIL SUNWOOD CONDOS, UNIT A -1 A/P /D Information Activity: B10 -0425 Type: A -MF Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: JRM Owner: AHBE, NINA B. - SIPAL, CAROLINE - Architect: TRD ARCHITECTS Phone: 970 - 479 -7387 Contractor: W.B. MONTAG /HOME IMPROVEMENT Phone: 970 - 748 -7394 Description: FULL INTERIOR REMODEL: KITCHEN, DINING, HALL, TV ROOM, BATHROOMS, BEDROOMS Reauested Inspectionls Item: 90 BLDG -Final Requestor: W.B. MONTAG /HOME IMPROVEMENT Comments: 331 -3111 Assigned To: JMONDRAGON Action: Time Exp: Inspection History Item: 60 BLDG - Sheetrock Nail 01/06/11 Inspector: Comment: Requested Time: 01:30 PM Phone: 970 - 748 -7394 Entered By: JMONDRAGON K y;erL-e_C- ** Approved ** nchand Item: 70 BLDG -Misc. "A pproved ** 01/24/11 Inspector: JRM Comment: COURTSEY Item: 90 BLDG -Final REPT131 Action: AP APPROVED ` be (''-40vllc� Action: AP APPROVED Run Id: 12718