HomeMy WebLinkAboutB10-0425NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
WO Vv
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
ADD /ALT MF BUILD PERMIT Permit #: B10 -0425
Job Address: 4507 MEADOW DR VAIL
Location......: SUNWOOD CONDOS, UNIT A -1
Parcel No....: 210112425001
OWNER AHBE, NINA B. - SIPAL, CAROL 11/26/2010
KATHERINE S. KODIAK TRUST- KOZMIN, JULIA
6331 S GENEVA CIR
ENGLEWOOD
CO 80111 -5437
ARCHITECT TRD ARCHITECTS 11/26/2010 Phone: 970 - 479 -7387
TOM DUBOIS
PO BOX 1492
VAIL
CO 81658
License: 0000001769
APPLICANT W.B. MONTAG /HOME IMPROVEMENT 11/26/2010 Phone: 970 - 748 -7394
P.O. BOX 3534
VAIL
CO 81658
License: 196 -B
CONTRACTOR W.B. MONTAG /HOME IMPROVEMENT 11/26/2010 Phone: 970 - 748 -7394
P.O. BOX 3534
VAIL
CO 81658
License: 196 -B
Description:
FULL INTERIOR REMODEL: KITCHEN, DINING, HALL, TV ROOM,
BATHROOMS, BEDROOMS
Project #:
Status .. :
Applied.
Issued ...
Expires ...:
PRJ10 -0782
ISSUED
11/26/2010
12/14/2010
06/12/2011
Occupancy:
Valuation: $49,000.00
Type Construction:
Total Sq Ft Added: 0
...,.. .
FEE SUMMARY ................� ....., .,� .......� >..�..,,, .....�..............��.......
Building Permit Fee ------ >
$633.65
Will Cal Fee --------------------- >
$4.00
Total Calculated Fees ------------- >
$1,829.52
Plan Check--------------- - - - - ->
$411.87
Use Tax Fee --------------------- >
$780.00
Additional Fees ---------- — ----------- >
$0.00
Add'[ Plan Check Hours ->
$0.00
Restuarant Plan Review - - - - ->
$0.00
TOTAL PERMIT FEES -- ----------- >
$1,829.52
Investigation------------ - - - - ->
$0.00
Recreation Fee------------ - - - - ->
$0.00
Payments -- ---------------------------- >
$1,829.52
Total Calculated Fees--- - - - - ->
$1,829.52
BALANCE DUE------------------ - - - - ->
$0.00
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the informatior
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 Ppe
Signature of Owner ontractor Date
Print Name
b Id —a It —co n st ru cti o n_pe rm it_041908
APPROVALS
Permit #: B10 -0425 as of 12 -14 -2010 Status: ISSUED
Item: 05100 BUILDING DEPARTMENT
12/14/2010 martin Action: AP
Item: 05110 ELECTRICAL REVIEW
12/14/201.0 martin Action: AP
Item: 05120 MECHANICAL REVIEW
12/14/2010 martin Action: AP
Item: 05130 PLUMBING REVIEW
12/14/2010 martin Action: AP
Item: 05600 FIRE DEPARTMENT
12/07/2010 mvaughan Action: AP
See the Conditions section of this Document for any that may apply.
b Id_a It_co nstruction_perm it_041908
CONDITIONS OF APPROVAL
Permit #: B10 -0425 as of 12 -14 -2010 Status: ISSUED
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Cond: 14
(BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO
BE SEALED WITH AN APPROVED FIRE MATERIAL.
Cond: 1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
bid_a It_co nstruction_pe rm it_041908
TOWN OF VAIL, COLORADO Statement
Statement Number: R100002009 Amount: $1,829.52 12/14/201011:37 AM
Payment Method: Check Init: LC
Notation: #2476 / WB
MONTAG HOME IMPROVEMENT
-----------------------------------------------------------------------------
Permit No: B10 -0425 Type: ADD /ALT MF BUILD PERMIT
Parcel No: 2101 -124- 2500 -1
Site Address: 4507 MEADOW DR VAIL
Location: SUNWOOD CONDOS, UNIT A -1
Total Fees: $1,829.52
This Payment: $1,829.52 Total ALL Pmts: $1,829.52
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code
--------------
Description
Current Pmts
BP
- - - - --
00100003111100
------------------------ - - - - --
BUILDING PERMIT FEES
------ - - - - --
633.65
PF
00100003112300
PLAN CHECK FEES
411.87
UT
11000003106000
USE TAX 4%
780.00
WC
00100003112800
WILL CALL INSPECTION FEE
4.00
Project S�tlreet Address: Office Use: Q�
Z ct� ��_ Project #:
(Number) (Street) (Suite #) DRB #:
Building/Complex Name: JJ`. V00 ,9& Building Permit # I/D • 0245
Contractor, Information-
Company: w • 3.A, —� 1 11a�, tV,rx1�•N�+l
Company address:
City: \ � 0 State: Tip. l
Contact Nam:
Contact Phone:
E-Mail
Town of Vail Contractor Registration No.: ` 0((o Q
X��
Contractor Signature (required)
Lot #: Block # Subdivision:
Detailed Description of Work:
r�Jf
(use additional sheet if necessary)
I Work Class:
New ( ) Addition ( ) Remodel ()0 Repair ( ) Other ( )
Work Type
Interior ()<) Exterior( ) Both( )
Property Information Type of Building:
Parcel # 1 ` 0 \ kg�-L 2s,d Single- Family ( ) Duplex ( ) Muni- Family (�)
(For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or i
visit www.eagleoounty.us/patie) i Commercial( ) Other( )
Tenant Name:
Owner Name: JQ- I & kikst
Valuations (Labor & MateriaD)
Building: $ l Lx�
Plumbing: $
Electrical: $ • Uo
Mechanical: $ Q —
Total: $ Cl ( c )
c :kdcWOrm *- Iitslbui ldinglcomm_lwildingjermit loolo9
Does a Fire Alarm Exist? Yes ( ) No P<)
Monitored Alarm? Yes ( i No (7Cj
Does a Sprinkler System Exist? Yes ( ) No (�
# & Type of Existing Fireplaces: Gas Appliances
Gas Log Wood/Pellet Wood Burning 4-
# & Type of Proposed Fireplaces: Gas Appliances
Gas Log Wood/Pellet Wood Burning _
Date Receiv °,,
NOV 2 3 2010
u
F VAIL
01 -OU-09
PROJECT OUTLINE
Renovate /remodel condominium as follows;
Remove and dispose of all existing construction debris currently in condominium and on
condominium back deck.
All -new prehung doors /doorjambs, bifold doors /doorjambs /headers, base trim, and
door /window casing will be finished using two coats clear, water -based polyurethane with a
satin finish.
All new file and grout will be sealed using standard matte finish sealer.
Install new white colored thermostats for baseboard heaters replacing existing
baseboard heater thermostats.
Install new white colored, Decora style switches and receptacles /switch covers
receptacle covers throughout the condominium; 24 duplex receptacles, 12 single poll switches,
6, 3-way switches, 5 single pole dimmer switches.
Kitchen /Dir ft room /Fireplace room:
Remove and dispose of existing kitchen lighting.
Install 6 new standard 6" can rights in ceiling. Can lights will have standard white trims.
Can fights will have 75 watt halogen right bulbs.
Remove and dispose of existing non - bearing kitchen "post" and rewire existing electrical
switches, electric receptacle, and phone line. Phone line will be rewired and located above the
kitchen counter near dining room window. Light switches will be rewired and located near
electrical breaker box. Electric receptacle will be rewired and located in the side of the kitchen
island base cabinets. A second electrical receptacle will be wired on the opposite side of the
kitchen island base cabinets using the some electrical circuit.
Move existing electric range 240 volt circuit from current location to new location in
kitchen island to allow for electric range installation.
Install 2 new GFI protected electrical receptacles above kitchen countertop.
Install new standard 120 volt under cabinet heater under kitchen sink cabinet.
Install power source and switchbox for the in floor heat system with a new 240 volt GFI
breaker.
Remove any existing floor file and prep floor for new file installation.
Install in floor heating system with seven day programmable thermostat. Thermostat will
be installed near kitchen cabinets /dining room window. Heating system /file will be installed on
the entire floor area from main exterior entrance, to doorway into TV room, approximately 260
ff2.
Install Ditra- Schlueter anti - fracture system over new in floor heating system.
Install approximately 260 ft .2 of 16 x 16 slate tiles on anti - fracture membrane using
standard thinset.
Seal all 16 x 16 slate tiles using standard matte finish sealer.
Install standard sanded grout in all newly created grout joints. Size of grout joints yet to
be determined. Grout color yet to be determined.
Install backsplash file above kitchen countertops /below kitchen cabinets using standard
wall tile mastic. Size and type of file and grout joints yet to be determined.
Install standard grout in all newly created grout joints. Size of grout joints yet to be
determined. Grout type and color yet to be determined.
Remove and save for reinstallation dining room chandelier and the main entryway wall
fight.
Remove all popcorn texture from ceiling.
Replace any missing drywall on walls and ceilings.
Patch any drywall where removed for new electrical installation.
Finish all new drywall to be flat and smooth.
Prep walls for new texture.
Apply a medium skip trowel texture to all walls and ceilings.
Apply one coat of drywall primer to all new drywall.
Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all
ceilings. Paint Sheen will be flat.
Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all
walls. Sheen will be eggshell.
Install new kitchen cabinets.
Install kitchen cabinet crown molding /trim.
Install new cabinet /drawer pulls /handles.
Oversee new granite countertops /sink installation.
Install new kitchen faucet, new kitchen drain hardware, new kitchen dispose all using
steel braided water supply lines and plastic drain piping.
Install existing refrigerator, new electric range, and new dishwasher with steel braided
water supply line.
Apply one coat of Uz2 stain Mocker /primer to 2' x 8' sub floor area in front of sliding
door. Approximately 16 ft?.
Install 9/16" x 5" #412 Austin Victorian K. knotty alder base trim where needed.
Install 5/8" x 3" #332 Austin /Victorian K. knotty alder casing around dining room
windows.
Reinstall dining room chandelier and the main entryway wall light.
TV roam:
Cap wet bar plumbing inside of wall.
Remove existing dangling wet bar wires.
Move existing dangling electrical receptacle to new location in wet bar area.
Receptacle location yet to be determined.
Install 2 new standard 6" can lights with wall light switch in ceiling of wet bar area. Light
switch location yet to be determined.
Install 2 new standard 6" can lights with wall light switch in ceiling of TV room area. Light
switch location yet to be determined.
Install 2 x 4 framing where needed in a bar area to allow for drywall installation.
Prep walls for new texture.
Remove all popcom texture from ceiling.
Replace any missing drywall on walls and ceiling.
Install square drywall comer bead where needed in wet bar area.
Patch any drywall where removed for plumbing work /new electrical installation.
Finish all new drywall to be flat and smooth.
Apply a medium skip trowel texture to all walls and ceiling.
Apply one coat of drywall primer to all new drywall.
Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all
ceilings. Paint Sheen will be flat.
Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all
walls. Sheen will be eggshell.
Install new 8'and 6' electric baseboard heaters using existing electric heater circuits.
Heater cover color will be Navajo white
Apply one coat of Kltz2 stain blocker /primer to 2' x 8' sub floor area in front of sliding
door. Approximately 16 ft?.
Install 9/16" x 5" #412 Austin Victorian K. knotty alder base trim where needed.
Hallway:
Remove wall light fixture and save for reinstallation.
Remove all popcorn texture from ceiling.
Replace any missing drywall on walls and ceiling.
Install square metal corner bead where needed.
Finish all new drywall to be flat and smooth.
Apply a medium skip trowel texture to all walls and ceilings.
Apply one coat of drywall primer to all new drywall.
Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all
ceilings. Paint Sheen will be flat.
Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all
walls. Sheen will be eggshell.
Reinstall wall fight fixture.
Install Knotty Alder, 2 panel, Flat panel, Square top, V Groove, 24" bifold door in hall
closet door opening using Johnson hardware.
Install 9/16" x 5" #412 Austin Victorian K. knotty alder base trim where needed.
Install 5/8" x 3" #332 Austin Victorian K. knotty alder casing around prehung doorframes.
Halway Bathroom:
Replace existing shower control and showerhead with new shower control and
showerhead.
Install framing for shower bench using 2 x 4 pressure - treated lumber.
Install new concrete shower pan using steel mesh reinforcement, standard concrete
shower pan drain hardware, and PVC shower pan drain liner.
Install 4 mill plastic vapor barrier around /on shower area framing.
Install %" cement board on walls and bench of shower area framing using 15/8" zinc
coated screws.
Install 12 x 12 porcelain tiles on the walls and bench with a 4 x 12 listelle on the walls, using
standard thinset. Size of grout joints yet to be determined.
Install pebble files on 12 x 12 mesh backing on shower floor using standard thinset.
Install grout in all newly created grout joints. Type of gout yet to be determined. Color of
gout yet to be determined.
Install standard glass shower enclosure /shower door.
Install new vanity.
Install new cabinet /drawer pulls /handles.
Oversee granite countertop /sinks installation.
Install chrome colored water shutoff valves for vanity sinks and toilet.
Install new faucets /drain hardware using new steel braided supply lines.
Install new 2' electric baseboard heater using existing electric heater circuit. Heater
cover color will be Navajo white.
Install Knotty Alder, 2 panel, Flat panel, Square top, V Groove, bifold door in water heater
closet opening using Johnson hardware.
Install new Knotty Alder, 2 panel, Rat panel, Square top, V Groove with oil rubbed bronze
hinges, 30" right -hand prehung toilet room door with lock set /handle set /latch plate.
Install new Knotty Alder, 2 panel, Hat panel, Square top, V Groove with oil rubbed bronze
hinges, 30" right -hand prehung hallway entrance door with lock set /handle set /latch plate.
Remove all popcorn texture from ceiling.
Replace any missing drywall on walls and ceiling.
Finish all new drywall to be flat and smooth.
Apply a medium skip trowel texture to all walls and ceilings.
Apply one coat of drywall primer to all new drywall.
Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all
ceilings. Paint Sheen will be flat.
Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all
walls. Sheen will be eggshell.
Install 2 new vanity light fixtures.
Install 5/8" x 3" #332 Austin Victorian K. knotty alder casing around alder doorframes.
Master Bathroom:
Replace existing exhaust fan with new Panasonic quiet exhaust fan.
Replace existing shower control and showerhead with new shower control and
showerhead.
Install new bathtub.
Install 4 mill plastic vapor barrier around /on tub /shower area framing.
Install 1/2" cement board on walls of shower area framing using 1 5/8" zinc coated screws
to allow for the installation.
Install 12 x 12 tiles on the walls of tub /shower area, with a 4 x 12 listelle on the walls, using
standard thinset. Size of grout joints yet to be determined.
Install standard grout in all newly created grout joints. Type of grout yet to be
determined. Color of grout yet to be determined.
Install 120 V power supply with switch box and new GFI protected breaker for in floor
heating system.
Install floor heating system using seven day programmable thermostat.
Install Ntra- Schlueter anti- fracture system over new in floor heating system.
Install 16 x 16 slate files using standard thinset. Approximately 35 ft .2. Size of grout joints
yet to be determined.
Seal slate tiles using standard matte finish sealer.
Install standard sanded grout in all newly created grout joints. Grout color yet to be
determined.
Install new vanity.
Install new cabinet /drawer pulls /handles.
Oversee granite countertop /sink installation.
Install new chrome colored water shutoff valves for vanity sink and toilet.
Install new faucet /drain hardware using new steel braided supply lines.
Install Knotty Alder, 2 panel, Flat panel, Square top, V Groove, 30" bifold door in linen
closet opening using Johnson hardware.
Install new Knotty Alder, 2 panel, Fiat panel, Square top, V Groove with oil rubbed bronze
hinges, 36" right -hand prehung hallway entrance door with lock set /handle set /latch plate.
Remove all popcom texture from ceiling.
Replace any missing drywall on walls and ceiling.
Finish all new drywall to be flat and smooth.
Apply a medium skip trowel texture to all walls and ceilings.
Install existing mirror above vanity.
Install new vanity fight fixture.
Install new toilet using wax ring and new wire mesh supply line.
Apply one coat of drywall primer to all new drywall.
Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all
ceilings. Point Sheen will be flat.
Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all
walls. Sheen will be eggshell.
Install 5/8" x 3" #332 Austin Victorian K. knotty alder casing around alder doorframes.
Master Bedroom:
ceiling.
Install switch and new power to new ceiling light junction box located in the center of
Remove and dispose of existing carpet and carpet padding.
Remove and dispose of existing closet doors, closet doorjambs /header, door and
window trim.
Remove all popcom texture from ceiling.
Apply a medium skip trowel texture to all walls and ceilings.
Apply one coat of drywall primer to all new drywall.
Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all
ceilings. Paint Sheen will be flat.
Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all
walls. Sheen will be eggshell.
Install Knotty Alder, 2 panel, Rat panel, Square top, V Groove with oil rubbed bronze
hinges, 30" right -hand prehung door with lock set /handle set /latch plate.
Install new knotty alder closet door jambs /header.
Install 2, Knotty Alder, 2 panel, Rat panel, Square top, V Groove, 36 inch doors with
bypass hardware in closet door opening.
Install new 4'and 3' electric baseboard heaters using existing electric heater circuits.
Heater cover color will be Navajo white.
Install 9/16" x 5" #412 Austin /Victorian K. knotty alder base trim where needed.
Install 5/8" x 3" #332 Austin /Victorian K. knotty alder casing around alder doorframes
and window where needed.
Install new cei ing fight fixture.
2nd Bedroom:
Install switch and new power to new ceiling light junction box located in the center of
ceiling.
Remove and dispose of existing carpet and carpet padding
Remove and dispose of existing closet doors, closet doorjambs /header, door and
window trim.
Remove all popcom texture from ceiling.
Apply a medium skip trowel texture to all walls and ceilings.
Apply one coat of drywall primer to all new drywall.
Apply one coat of interior latex paint, Benjamin Moore color #INT.RM "white dove" to all
ceilings. Paint Sheen will be flat.
Apply one coat of interior latex paint, Benjamin Moore color #HC45, "shaker beige" to all
walls. Sheen will be eggshell.
Install Knotty Alder, 2 panel, Hat panel, Square top, V Groove with oil rubbed bronze
hinges, 30" left -hand prehung knotty alder door with lock set /handle set /latch plate.
Install new knotty alder closet door jambs /header.
Install 2, Knotty Alder, 2 panel, Rat panel, Square top, V Groove, 36 inch doors with
bypass hardware in closet door opening.
Install new 4'and 3' electric baseboard heaters using existing electric heater circuits.
Heater cover color will be Navajo white.
Install 9/16" x 5" #412 Austin Victorian K. knotty alder base trim where needed.
Install 5/8" x 3" #332 Austin /Victorian K. knotty alder casing around alder doorframes
and window where needed.
Install new ceding fight fixture.
V
Asbestos Inspection and Sampling Report
Sunwood Condos 4594 Meadow Dr. UnitA -1, Vail, Colorado 81657
Presented to:
Mr. Jon Greener
Ridgeline Builders
PO Box 3314
Vail, CO 81620
(970) 331 -9990
Performed & Prepared by:
Mr. Nate Skinner
DS Consulting, Inc.
PO Box 6864
Avon, CO 81620
(303) 917 -8081
Project Details:
DSC Project #: 2656
Conducted: August 18, 2010
Consulting
OP ,
EXECUTIVE SUMMARY
On August 18, 2010, Mr. Nate Skinner of DS Consulting, Inc. (DSC) performed a limited inspection and
asbestos bulk - sampling at Sunwood Condos 4594 Meadow Dr. Unit A -1, Vail, Colorado, in order to identify
potentially hazardous friable and non - friable asbestos - containing materials (ACM) within the above -
referenced, single family residence where renovations activities are planned. The Colorado Department of
Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos - containing material
(ACM) as a material containing more than 1% asbestos.
Mr. Skinner performed asbestos bulk - sampling of drywall (surfacing material) in a total of six (6) locations
within the residence (see Appendix A for sample locations). All six (6) bulk - samples were analyzed by
Aerobiology Laboratory Associates, Inc. (NVLAP #200860 -0) with all six (6) laboratory results reporting
as negative for asbestos (see Appendix C for laboratory results).
2
PROJECT OVERVIEW
I. Introduction
A limited inspection and bulk - sampling for ACM was conducted at Sunwood Condos 4594 Meadow Dr.
Unit A -1, Vail, Colorado, by Mr. Skinner on August 18, 2010, at the request of Mr. Jon Greener with
Ridgeline Builders. Mr. Skinner is a Colorado State Certified Building Inspector; having EPA Accreditation
#16227 (see Appendix B for certificate). The purpose of the inspection was to identify, sample and assess
potentially hazardous friable and non - friable ACM within the residence.
II. Structural Design
The structure is a single -level unit, in a multi -unit complex.
III. Sampling and Analytical Procedures
The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building
Inspector qualified by experience, education and training in the recognition of potential ACM and
approved bulk - sampling techniques. The asbestos bulk- sampling was conducted on suspect ACM with a
limited number of bulk - samples being collected within the residence.
The inspection, assessment and sampling were performed in accordance with Environmental Protection
Agency / AHERA recommended procedures. These procedures call for the visual inspection of the area of
concern and the collection and analysis of representative bulk - samples of suspect material.
Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not
broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be
located in these and other inaccessible areas.
Random bulk - samples, representative of the suspect asbestos - containing building materials (ACBM) of
each homogeneous area (HA), were collected according to the guidelines published as Environmental
Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA),15 USC, Sections
2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the
following criteria:
1. The distribution of the suspect material throughout the HA.
2. The suspect material's physical characteristics and application.
3. Random sampling patterns determined for each HA.
Suspect materials sampled and analyzed should be considered to be representative of materials in each
HA if they exhibit similar physical characteristics and the application of the sampled material can be
correlated to the application of un- sampled material. Bulk- samples collected were analyzed utilizing the
EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993)
and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the
bulk - samples was performed on the "date reported," as listed in the bulk - sample analysis report.
r IV. Notes on Report Format
Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were
divided into three classifications:
1. Surfacing Material: sprayed or troweled onto structural building member.
2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation.
3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl /linoleum, ceiling tiles,
insulation, and finishing materials.
Condition assessments were performed by the accredited inspector at the time of inspection. Condition
assessments are listed in the following section. Ratings of "good," "damaged," and "significantly
damaged" are meant to indicate the overall condition of the material.
A material in "good" condition has no visible damage or deterioration, or showing only very limited
damage or deterioration.
A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered,
water - stained, gouged, marred or otherwise abraded over less than one -tenth of the surface if the
damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or
debris similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence. A material in "significantly damaged" condition has one or more of the following
characteristics:
• The surface is crumbling or blistered over at least one -tenth of the surface if the damage is evenly
distributed (one - quarter if the damage is localized).
• One -tenth (one - quarter, if localized) of the material is hanging from the surface, deteriorated, or
showing adhesive failure.
• Water stains, gouges, or mars are over at least one -tenth of the surface if the damage is evenly
distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris
similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence.
Response- action recommendations for asbestos - containing HAs are listed in the section VII.
Recommendations may be for more than one HA, if materials are alike. Recommendations are either
"general" or "immediate." An immediate recommendation indicates the presence of asbestos greater
than 1% within the bulk- sample, or a bulk - sample in the same HA, and should be addressed accordingly.
A general recommendation indicates asbestos does not exist greater than 1% within the bulk - sample, or
a bulk - sample in the same HA, and no further abatement activities are required for removal of the
material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for
asbestos greater than 1% unless it is analyzed by the point -count method to be less than 1 %.
V. Inspector Comments
No asbestos - containing material (ACM) was identified during the bulk - sampling conducted at Sunwood
Condos 4594 Meadow Dr. Unit A -1, Vail, Colorado. A total of six (6) bulk - samples were collected from
drywall within the above - referenced residence. All six (6) bulk- samples tested negative for asbestos.
4
VI. Homogeneous Area Descriptions
The following section contains sampled HA descriptions and sample locations. Percent - asbestos content
for each sample indicated can vary depending on sample locations, homogeneity of the materials, and
type of application. The following samples were collected from the single family residence at Sunwood
Condos 4594 Meadow Dr. Unit A -1, Vail, Colorado, on August 18, 2010. The quantities are
approximations and are subject to field verification:
Homogeneous Area #01
Sample #: DC1 -1
Homogeneous Area #01
Sample #: DC1 -2
Sample Description: Drywall
Sample Description: Drywall
Sample Location: Living Room Ceiling
Sample Location: Hallway Ceiling
Material Classification: Surfacing Material
Material Classification: Surfacing Material
Material Quantity. +/- 900ft2
Material Quantity: +/- 900ft2
Material Condition: Good
Material Condition: Good
Physical Description (layers): White texture; White
foamy texture; White compound; White /tan
drywall
physical Description (layers): White foamy texture
w/ tan paint; White /tan drywall
Asbestos Detected (layers): Negative; Negative;
Negative; Negative
Asbestos Detected (layers): Negative; Negative
Recommendations: GENERAL - See Section VII
Recommendations. GENERAL - See Section VII
Homogeneous Area #0 1
Sample #: DC1 -3
Homogeneous Area #02
Sample #: DW1 -1
Sample Description: Drywall
Sample Description: Drywall
Sample Location: Bedroom 1 Ceiling
Sample Location: Living Room Wall
Material Classification: Surfacing Material
Material Classification: Surfacing Material
Material Quantity. +/- 900ft2
Material Quantity. +/- 900ft2
Material Condition: Good
Material Condition: Good
Physical Description (layers): White compound;
White texture w/ white paint; White /tan drywall
Physical Description (layers): White tape; White
joint compound; White texture w/ cream paint;
Gra tan drywall
Asbestos Detected (layers): Negative; Negative;
Negative; Negative
Asbestos Detected (layers): Negative; Negative;
Negative; Negative
Recommendations: GENERAL - See Section VII
Recommendations: GENERAL - See Section VII
5
Homogeneous Area #02
Sample #: DWI-2
Homogeneous Area #02
Sample #: DW1 -3
Sample Description: Drywall
Sample Description: Drywall
Sample Location: Hallway Wall
Sample Location: Bedroom 1 Wall
Material Classification: Surfacing Material
Material Classification: Surfacing Material
Material Quantity. +/- 900ft2
Material Quantity: +/- 900ft2
Material Condition: Good
Material Condition: Good
Physical Description (layers): White tape; White
joint compound; White compound w/ white paint;
White compound w/ cream paint; Gray /tan
d all
physical Description (layers): White tape; White
joint compound; White texture w/ white paint;
Gray /tan drywall
Asbestos Detected (layers): Negative; Negative;
Negative; Negative
Asbestos Detected (layers): Negative; Negative;
Negative; Negative
Recommendations: GENERAL - See Section VII
Recommendations: GENERAL - See Section VII
VII. Recommendations
GENERAL:
The laboratory results of the potential ACM sampled at Sunwood Condos 4594 Meadow Dr. Unit A -1, Vail,
Colorado, indicate that all six (6) bulk - samples of drywall collected were reported as negative for
asbestos. Therefore, no professional abatement activities are recommended to remove the above -
referenced material.
I
APPENDIX A
SAMPLE LOCATIONS
APPENDIX B
CERTIFICATION
STATE OF COLORADO
ASBESTOS
CERTIFICATION*
Colorado Department of Public Health
and Environment
Air Pollution Control Division
This certifies that
Nathan Skinner
Certification No: 16227
has met the requirements of 25 -7 -507, C.R.S. and Air Quality Control
Commission Regulation No. 8, Part B, and is hereby certified by the
state of Colorado in the following discipline:
Building Inspector*
Issued: 2/6/2010
Expires on: 2/6/2011
' This crrrifirare is wAd wwfp Y'&k 66c pwnminw wja tvrrrwr DYrisiaw- app+wvrd rraiwiap copra
c ulian in 1k, dh *,—spr feed ab-
APPENDIX C
LABORATORY ANALYSIS
` kt AERUDIULOt1y LADORATORY
ASSOCIATES, INCORPORATED
X� CONSULTING LABORATORY
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
303.232.3746
Certificate of Analysis www.aerobiolony.net
Client Name
Street address
DS Consluting, Inc.
5366 Flatrock Ct. Minn n� Date Collected:
08/18/10
Number
of
La ers %
W `/ ISLrJ Date Received:
08 /18 /10
City, State ZIP
Morrison, CO 80465 Date Analyzed:
08/18/10
Attn:
Nate Skinner #200860 -0 Date Reported:
08/18/10
Client Project Name:
Sunwood Condos Unit A8 Vail Project ID:
105881
4,5%
Job ID:
CHRY= Chrysotile
Test Requested:
3002, Asbestos in Bulk Samples
105881 -1B
Method:
Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA -600/R- 93/116. July 1993.
4,10%
Sample Identification
Physical Description of Sample;
Additional Comments
Homo-
geneous
es /no
Number
of
La ers %
Asbestos Detected
Non - Asbestos
Fibers
area %
Non - Fibrous
Material
area %
Matrix
Material
(composition)
MW = Mineral Wool
Client
Lab Sample Number
DC1 -1
1058814A
White Texture
N
4,5%
Negative
CHRY= Chrysotile
100
C,M
105881 -1B
White Foamy Texture
N
4,10%
Negative
Adam Humphreys
100
C,M
105881 -1C
White Compound
N
4,15%
Negative
NAC = Non- Asbestiform AC
100
G
105881 -1D
White /Tan Drywall
N
4,70%
Negative
30%
CELL
70
G
DC 1 -2
105881 -2A
White Foamy Texture w/ Tan Paint
N
2,15%
Negative
100
C,M
105881 -2B
White/Tan Drywall
N
2,85%
Negative
30%
CELL
70
G
DCl -3
105881 -3A
White Compound
N
3,5%
Negative
100
G,M
105881 -313
White Texture w/ White Paint
N
3,15%
Negative
100
C,M
105881 -3C
White/Tan Drywall
N
3,80%
Negative
30%
CELL
70
G
DW24
1058814A
White Tape
N
4,10%
Negative
97%
CELL
3
B
A = Amosite
CELL = Cellulose
Q = Quartz
f
AC = Actinolite
MW = Mineral Wool
C = Carbonates
/ % b - — ` —` -
, _ _ _ .
AN = Anthophyllite
FBG = Fiberglass
V = Vermiculite
CHRY= Chrysotile
SYN = Synthetic
G = Gypsum
CR = Crocidolite
WO = Wollastonite
M = Mica
Adam Humphreys
Adam Humphreys
TR = Tremolite
NTR = Non- Asbestiform TR
T = Tar
Laboratory Analyst
Asbestos Laboratory Supervisor
Trace =Less Than 1%
NAC = Non- Asbestiform AC
P = Perlite
FT = Fibrous Talc
O = Organic
AH = Animal Hair
B = Binder
OP = Opaques
\_ AERODIULUCiy LADORATORY
1'1 ASSOCIATES, INCORPORATED
�\ CONSULTING LABORATORY
Certificate of Analysis
13949 W. Colfax Ave
Suite 205'
Lakewood, CO 80401
303.232.3746
www.aerobiology.net
Client Name
Street address
DS Consluting, Inc.
5366 Flatrock Ct.
Date Collected:
08/18/10
Asbestos Detected
Non - Asbestos
Fibers
area %
���� Date Received:
08/18/10
City, State ZIP
Morrison, CO 80465
Date Analyzed:
08/18/10
Attn:
Nate Skinncr
#200860 -0 Date Reported:
08/18/10
Client Project Name:
Sumvood Condos Unit A8 Vail
Project ID:
105881
1058814C
White Texture w/ Cream Paint
Job ID:
4,25%
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993.
Sample Identification
Physical Description of Sample;
Additional Comments
Homo-
geneous
es /no
Number
of
La ers %
Asbestos Detected
Non - Asbestos
Fibers
area %
Non - Fibrous
Material
area %
Matrix
Material
(composition)
V = Vermiculite
Client
Lab Sample Number
DW24
105881 -413
White Joint Compound
N
4,25%
Negative
T = Tar
100
G,M
1058814C
White Texture w/ Cream Paint
N
4,25%
Negative
AH =Animal Hair
100
C,M
1058814D
Gray /Tan Drywall
N
4,40%
Negative
35%
CELL
65
G
DW2 -2
105881 -5A
White Tape
N
5,10%
Negative
97%
CELL
3
B
105881 -513
White Joint Compound
N
5,15%
Negative
100
G,M
105881 -5C
White Compound w/ White Paint
N
5,20%
Negative
100
C M
105881 -51)
White Compound w/ Cream Paint
N
5,20%
Negative
100
C,M
105881 -5E
Gray/Tan Drywall
N
5,35%
Negative
50%
CELL
50
G
DW2 -3
105881 -6A
White Tape
N
4,10%
Negative
97%
CELL
3
B
105881 -6B
White Joint Compound
N
4,15%
Negative
100
G,M
A = Amosite
CELL = Cellulose
Q = Quartz
AC = Actinolite
MW = Mineral Wool
C = Carbonates
AN = Anthophyllite
FBG = Fiberglass
V = Vermiculite
-' ✓` "" - CHRY= Chrysotile
SYN = Synthetic
G = Gypsum
CR = Crocidolite
WO = Wollastonite
M = Mica
TR = Tremolite
Adam Humphreys Adam Humphreys
NTR = Non - Asbestiform TR
T = Tar
Trace =Less Than I%
Laboratory Analyst Asbestos Laboratory Supervisor
NAC = Non - Asbestiform AC
P = Perlite
FT = Fibrous Talc
O = Organic
AH =Animal Hair
B = Binder
_
OP = Opaques
`k AEROD1010(.iy LADORATORy
—.—� ASSOCIATES, INCORPORATED
CONSULTING LABORATORY
Certificate of Analysis
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
303.232.3746
www.aerobioloay.net
Client Name
Street address
DS Consluting, Inc.
5366 Flatrock Ct.
Date Collected:
08/18/10
Asbestos Detected
Non - Asbestos
Fibers
area %
KWR,� Date Received:
08/18/10
City, State ZIP
Morrison. CO 80465
Date Analyzed:
08/18/10
Ann:
Nate Skinner
#200860 -0 Date Reported:
08/18/10
Client Project Name:
Sunwood Condos Unit A8 Vail
Project ID:
105881
105881 -613
Gray /Tan Drywall
Job ID:
4,60%
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993.
Sample Identification
Physical Description of Sample;
Additional Comments
Homo-
geneous
es /no
Number
of
La ers %
Asbestos Detected
Non - Asbestos
Fibers
area %
Non- Fibrous
Material
area %
Matrix
Material
(composition)
V = Vermiculite
Client
Lab Sample Number
DW2 -3
105881 -6C
White Texture w/ White Paint
N
4,15%
Negative
T = Tar
100
C,M
105881 -613
Gray /Tan Drywall
N
4,60%
Negative
40%
CELL
60
G
OP ^Opaques
Adam Humphreys
Laboratory Analyst
Haam rtumpnreys
Asbestos Laboratory Supervisor
A = Amosite
CELL = Cellulose
Q = Quartz
AC = Actinolite
MW = Mineral Wool
C = Carbonates
AN = Anthophyllite
FBG = Fiberglass
V = Vermiculite
CHRY= Chrysotile
SYN = Synthetic
G = Gypsum
CR = Crocidolite
WO = Wollastonite
M = Mica
TR = Tremolite
NTR = Non - Asbestiform TR
T = Tar
Trace =Less Than 1%
NAC = Non - Asbestiform AC
P = Perlite
FT = Fibrous Talc
O = Organic
AH =Animal Hair
B = Binder
OP ^Opaques
AERObiolocjy LAbORATORy
13949 W. Colfax Ave
ASSOCIATES, INCORPORATED
Suite 205
Lakewood, CO 80401
CONSULTING LABORATORY
303.232.3746
Certificate of Analysis
www.aerobiolo_q net
DS Consluting, Inc.
5366 Flatrock Ct.
Date Collected:
08/18/10
Morrison, CO 80465
MWa ?
Date Received:
Date Analyzed:
08/18/10
08 /I8 /10
Nate Skinner
#200860 -0
Date Reported:
08/18/10
Client Project Name: Sunwood Condos Unit A8 Vail
Project ID:
105881
Job ID:
General Notes
♦ Negative indicates no asbestos was detected; the method detection limit is 1 %.
♦ Trace or " <1" indicates asbestos was identified in the sample, but the concentration is less than the method detection limit of 1 %.
♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos
minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the
asbestiform variety of the mineral reibekite.
♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM.
For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi - quantitative bulk TEM
floor tile analysis is accepted under the NESHAPS regulations.
♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation
of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.
♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days
before discarding. A shipping and handling charge will be assessed for the return of any samples.
Notes Required by NVLAP
♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
♦ This test report relates only to the items tested or calibrated.
♦ This report is not valid unless it bears the name of a NVLAP- approved signatory.
♦ Any reproduction of this document must include the entire document in order for the report to be valid.
13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746
03 -01 -2011 Inspection Request Reporting Page 6
4:12 pm Vail, CO - City 0
Requested Inspect Date: Wednesday, March 02, 2011
Inspection Area: JRM
Site Address: 4507 MEADOW DR VAIL
SUNWOOD CONDOS, UNIT A -1
A/P /D Information
Activity: B10 -0425 Type: A -MF Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: Insp Area: JRM
Owner: AHBE, NINA B. - SIPAL, CAROLINE -
Architect: TRD ARCHITECTS Phone: 970 - 479 -7387
Contractor: W.B. MONTAG /HOME IMPROVEMENT Phone: 970 - 748 -7394
Description: FULL INTERIOR REMODEL: KITCHEN, DINING, HALL, TV ROOM, BATHROOMS, BEDROOMS
Reauested Inspectionls
Item: 90 BLDG -Final
Requestor: W.B. MONTAG /HOME IMPROVEMENT
Comments: 331 -3111
Assigned To: JMONDRAGON
Action: Time Exp:
Inspection History
Item: 60 BLDG - Sheetrock Nail
01/06/11 Inspector:
Comment:
Requested Time: 01:30 PM
Phone: 970 - 748 -7394
Entered By: JMONDRAGON K
y;erL-e_C-
** Approved **
nchand
Item: 70 BLDG -Misc. "A pproved **
01/24/11 Inspector: JRM
Comment: COURTSEY
Item: 90 BLDG -Final
REPT131
Action: AP APPROVED ` be (''-40vllc�
Action: AP APPROVED
Run Id: 12718