NEW FAUX BEAM �
_ �
8'WALLS WITH CEILING TO ENCLOSE SPACE � �
�-_�
� �
�
BEDROOM 1 2 2 BEDROOM 2 MASTER
�
EDR M
�
INCREASE SOFFIT
B 00
EXISTING ROOF SLOPES AND FORMS
NOT TO BE DISTURBED OR CHANGED
P�
INCREASE SOFFIT
2
' P-L 4-060 �
4 r,
OPEN CEILING TO FULL HEIGHT- - / G E N E R A L N 0 T E S w
ROOF FORMS AND SHAPES NOT TO BE DISTURBED � �
ALL INFORMATION SHALL BE PROVIDED ��
2 ON THESE DRAWINGS �
THIS SYMBOL LEGEND IS FOR GENERAL REFERENCE
P-L 4-057 P-L 4-056 P-L 4-058 USE. SPECIFIC REQUIREMENTS ON THE PLANS OR
� SCHEDULES TAKE PRECEDENCE
i
BATH DROP CEILING HEIGHT AT 11' �� � � � ALL DEVICES ARE TO BE INSTALLED FLUSH
____ j UNLESS OTHERWISE NOTED
BATH 3
,
%
ALL INITIATING, NOTIFICATION, CONTROL AND
�� �'�� '� �� MONITORING DEVICES REQUIRE BACK BOXES
o „ ,,;, „ , �; ; � % � % 4-061
W�� � ALL INDICATING DEVICES TO BE MOUNTED 80"TO •
BATH 1 �� �
�/ ��� � CENTER A.F.F. UNLESS OTHERWISE NOTED �
�
' " �---------- -------- MOUNTING HEIGHTS SHOWN ONTHE PLANSTAKE ��
EXIST. � ' ' ,�%� � EXIST. PRECEDENCE OVER THIS LEGEND
�P SLOPE SLOPE
NEW EXPOSED FRAMING - ► � ��� CHECK ALL DOOR SWINGS AND CABINETRY ^
�� , ELEVATIONS BEFORE INSTALLING ANY DEVICE �
LOFT 1 ��%� LOFT 2 BoxEs
0 0 � ALL INITIATING CIRCUITS TO BE 18 AWG FPL � �
� �� UNLESS OTHERWISE INDICATED � �
� �
DW P- 4-086 � / 2 P-L 4-087 ALL INDICATING CIRCUITS TO BE 14 AWG FPL �1 U � U
� �� �� .
, UNLESS OTHERWISE INDICATED T^ w � (n
� KITCHEN — — — �% ; ���'� SHOP DRAWINGS ARE FOR SCHEMATIC PURPOSES � � � �
�/ �;
� �� 16�-8° ONLY. CONTRACTOR TO ROUTE WIRE PER SITE � �
O P-L 4-OrJ9 ��� CEILING REQUIREMENTS � � � �
UP TO � �:' i /�� � NO DETECTORTO BE INSTALLED WITHIN 36" OF �'
LINE OF EXISTING LOFT ABOVE � � � � �%/,j ANY AIR DIFFUSER � � �-+ �
DEVICE NEW EXPOSED FRAMING � � �;� j� -�„ � M Q � �
� � ABOVE LOFT EXPANDED SOUTH 18" � � �" DOOR HOLDER WIRE TO BE 14 AWG UNLESS � (� � � O
���� � OTHERWISE INDICATED
EXIST. EXIST. SYSTEM IS ID# IS NEXT TO EACH DEVICE AND MUST ~� 0 J ¢i U
SLOPE SLOPE �q � O � �
� FROM BE FIELD PROGRAMMED BY INSTALLER
� DEVICE 27'-6" /C CANDELA &VOLUME SETTING FOR INDICATING �/ U � O
LIVWG AREA � 15'-0" DEVICES IS NEXTTO DEVICE w � W � Q
CEILING CEILING
BELOW EXAMPLE: CANDELA = 15, VOLUME LOW � z J C,Q �
\ HEIGHT HEIGHT CM 15� EX = EXISTING � � 00 (a
2 P-L 4-062 g CM = CEILING MOUNT O (n �Q .0
WP = WATER PROOF 0 Q L
--- � ALL HORNS SET FOR TEMPORAL SOUNDING � U U N
6:12 6:12 EX = EXISTING WHEN ADDED TO ANY ITEM ON LEGEND n
12'-7" w � � �
HEIGHT L E G E N D � � z �
� � �
Q J-BOX �
Q MANUAL STATION - PULL STATION ��
WRAP OR�F HEAT DETECTOR - FIXED/RATE OF RISE �
FIREPLACE w
O2 P � PHOTOELECTRIC SMOKE DETECTOR - LOCAL SOUNDER ~j
F-1
Unit 703 OP PHOTOELECTRIC SMOKE DETECTOR �
Level 2 Floor Plan O2 PD PHOTOELECTRIC DUCT SMOKE DETECTOR
Unit 703 � � ��Cx�'.E:�7li[tt1 S��c�r1 2 P 1 R/FPHOTOELECTRIC SMOKE DETECTOR W/ HEAT DETECTOR
�� E � '�t`-`!)"-'i:: 5�?�Gif14" i�t=,�:�� � VALVE WITH TAMPER SWITCH �
Level 1 Floor Plan ����� [ � ��;�F�c.��.}�� -- E��:��,�;�„�
f � #,e:��i,� �� ��s�,bn3�t q O
� �A!��1�E,c,c��rt;�[���n5 Ea�nq��±�, ♦ PRESSURE DETECTOR/SWITCH �
4 y � ��lia i:��!�EI+! �;}�"€}E;��qr�}}4.s?�1��1i�1�ir'{��yNFI l 1ti�-s�'St��C�3�1r€�t)t Uf��1� � FLOW DETECTOR/SWITCH �
�'r;,
� ,,, 6 t rd �er��� co �t����r7 ti�i�l� t��[ �r f�irr�,tion��ver� i�� tht �
Q d J J . �� �3 `{ r. �,. 3 � '�
�:, a 3 �
W a � ¢ � y a z �
�.n � z z � � l7 � � ¢ � O � �;;j�}s(zc.f{,�r(14 L1fT3t �115 ��ls i7L�I4Ji7�F};�'.�il i_a .`iiE�c�.C{kD tfl€? CF�;�?11fE; �f �
! i rn�. ;t�s
a �'�, o � ❑ � � ° � a � a � ° °o } p o�k��' ( icl'17 t L���� �FiiC�.�fr{71�5 ❑Q SPEAKER/HORN (ELECTRIC HORN) � U
S�QUENCE DF � o � � � m � � 2 � Q � � Q m o � Q ¢ !:C t� ��':;r 4,3�;5�J4�1�i�,��li�F c�rrii=i�3r}� 5 1^1f11Ch 5ilt�ll �?t CC3t��ll �1P;1-]t�C� �
u ¢ � � � � � z � p v ¢ a o a c"'�,n m �•�, c7 J Gi�; N-'�3iE-<"r�t lfl:i j1f �fE, �'?11��1u`iHCf 1�]�t�r,(:�i5 �Ilij tLf.flalit�llE;'�Ql � HORN WITH LIGHT AS ONE ASSEMBLY
� z � �;ari 1� �' t�ti�n tr nil u�,,rk wRf�-� t,i�t��7f�II otl�cr ir�tuc��ttru� � U �
J � ¢ z ,�r � � � t= � � z w �,,, Jo �
, W � V ,� a� � O F [] � � 4 � � � Q D m r f �i:�F G`��,�Ga�a i' f r
r� ,Q � � ° w z � � "` ;n o q w ° � _ � � t!`�E'. �� �i��i;'�Of�+ }1E.�'fOrr77�1i�i:E'. �f}�i;;!n��;tk. ;O� REMOTE INDICATOR LIGHT '`' � �
� a �' � ❑ "' � z � z o z 4 � J � D �{.ia `:1:�ff1� �.{)�5 f�C��(��lF'Vf;��9`; i;Ofllf�lC.IC`f r��f1r5 1't:SJ�QI1Si�"��;i�lf?S IO �RL � � i--�
� W w z � o � a � ; � �
g ❑ C7 w (:E7f�1iJ�' �"�!��1 a�f�E.?)�fC���J��C{�{�L �bf��;��1EP..tIC�li Ci�EJ<if3lZr`1alUI� f "'Ulf'EI71E)[�fS, �� M
z � z � � � z � � a z �
¢ � o F � � r � ,� Q � o � � � ��{ 'c r ;O� UGHT (LAMP, SIGNAL LIGHT, INDICATOR LAMP, STROBE) w
❑EVICE DESCRIPTIC7N ¢ � r
II/IANLIAL PLILLSTATIflN'S """`"`����� � � �
� }� X X C'i.}�=1_,.�_ .Y..��� F�� � O
� Digitally signed by FACP FIRE ALARM CONTROL PANEL � 0 U
SY53EM SMOKE DETECTORS M � c h a �
� X � � Michael McGee W I R E - L E G E N D - C 0 N D U I T RPS FIRE ALARM REMOTE POWER SUPPLY Q J •�
SYSTEM HEAT DETE�TORS � }( }( �( DN: cn=Michael P R 0 J E C T N 0 T E S � ANN REMOTE ANNUNCIATOR PANEL >
McGee,o=Vail Fire& a\- i$i4 FP�P ARMORE� cas�E � � �
���,= I" EMT Q
N �� �� ����� � ���� — � � ELEV.�C]BBYI5NAF7/EQUIP.RM.SMOKE � �( }( }( EfT1eI"g211Cy S2fVIC25, � 14/2 FPLR � � CONTROL RELAY � �
e I ou=Deput Chief, = IS/8 FPL ARMORED CABLE Z I/2" EMT R
y • SMOKE DETECTORS TO BE REMOVED AND � n�n END OF LINE RESISTOR �
HEATDETECT�RS(ELEV.SHAFT,EQUIP.RM.} � �( x �( x email=mmcgee@vailg REPLACED WITH HEAT DETECTORS �� �= 3/4° EMT �rv
WATERFL�W SWITCHES � x }� �( x OV.COI'Tl, C-US DURING CONSTRUCTION j u �- �4�4 FP�R 40 LOW TEMPERATURE SENSOR-40 DEG. SET POINT M�-�
M c G e e • ALL WIRING TO BE REPLACED WITH ED-- 18/2 FPLR �
Date: 2���.� �.�5 MM MONITOR MODULE
ARMORED FPL CABLE /� �
VALVETAMPERSWITCHES ,X }�, 09:57:20-06�00� • NO DEVICES TO BE ADDED OR REMOVED / r \= 18/4 FPLR PRM POWER SUPERVISION RELAY Q
REM4TEPOWERSUPPLYMbNITOR WHEN COMPLETE-MINOR RELOCATION G 14/2 FPLP ARMORED CABLE o0
X }( ONLY DUE CEILING REFINISH AND o SYNC MODULE �
- ADDITION OF CEILING FANS H0= 12/2 FPLP ARMORED CABLE TS DUCT DETECTOR TEST SWITCH �
�
AC RpWER LOS$ �{ � �( � 12/2 FPLR PSR POLARITY REVERSAL MODULE
GROUND FAULT � }�
t3PEM CIRCUIT/SWORTCIRCUIT � �
DA TE DRA WN B NO TES DRAWN �M
UNITSMOKEDETECTORS �( �{ 9—>-10 JM FIRE_ALARM DESIGN CHECKED SM
AMERICAN PROTECTION SYSTEMS, INC. ASSUMES NO
KNOXBO?fQPENING{WHERERERUiRED} � x RESPONSIBILITY FOR COMPLIANCE WITH ALL FEDERAL ADA DATE s-�-�o
NOTE: ELEVATOR RECALL CONSISTS OF PRIMARY AND SECdNQARY RECALL.PRIMARY RECALL IS TO THE GROUN6 FL40R,SECi7NC7ARY f5 R E Q U I R E M E NTS I N TH E D E S I G N O F TH I S SYST E M. SHEET �
TO THE 2ND FLC}OR.PRIMARY RECALL OCClJRS WFqEN THE SMOKE DETEGTORS IN THE ELEVATOR EQIJIPMENT RDQM,SHAFT,OR
ELEVATOR L08BIE5{E3(CEPT GRDUND FLflQR)ACTIVATE.SECONQARY REC&LC OCCURS WHEN THE SIVIQKE DETECTDRS LOCATED IN THE
GROUND FLOOR ELEVATOR LO�BIES ACTIVATE. # OF
SHEETS 1