Loading...
HomeMy WebLinkAboutF10-0088 specsMaterial Submittal FOR VAIL RUN SPA/POOL 1000 LIONS RIDGE LOOP VAIL, CO 81657 Tenant Remodel Prepared by: Jeff Hagan Project Manager Western States Fire Protection Co. 7026 S. Tucson Way Centennial, CO 80112 Phone (303) 792-0022 Fax (303) 792-9049 Cell (303-549-9553 Email jeff.hagan@wsfp.us WSFP #CS0997 October 24, 2010 MATERIAL INDEX Description Model Manufacturer I.Sprinkler Heads A. Standard Spray Quick Response Upright Sprinkler F1FR-R3625 Reliable B. Standard Spray Quick Response Semi-Recessed Pendant F1FR-R3615 Reliable III. Pipe – 1-1/2” and smaller threaded A. Black Schedule 40 Pipe ASTM A 795 Varies** IV. Pipe – 2” and larger grooved A. Black Schedule 10 Pipe ASTM A135 Varies** V. Cast Iron Fittings Varies Varies** VI. Pipe Hangers (Per NFPA 13) A. All Thread Rod Fig. 100 Tolco B. Adjustable Ring Hanger Fig. 200 Tolco C. C-Clamp Top Beam w/Locknut Fig. 68 Tolco VII. Grooved Fittings A. Grooved Firelock Fittings Varies Victaulic B. Grooved Firelock Rigid Couplings Style 005 Victaulic C. Mechanical T, Bolted Branch Outlet Style 920/922 Victaulic D. Grooved Concentric Reducer Style 50/51 Victaulic **Because of the current escalation occurring with steel, WSFP reserves the right to substitute pipe as required to meet project schedules. ModelF1FRSprinklerTypes StandardUpright StandardPendent Conventional VerticalSidewall HorizontalSidewall –HSW1Deflector ModelF1FRRecessedSprinklerTypes RecessedPendent RecessedHorizontalSidewall –HSW1Deflector ModelF1FR ModelF1FRRecessed QuickResponse Sprinklers TheReliableAutomaticSprinklerCo.,Inc.525NorthMacQuestenParkway,MountVernon,NewYork10552 Bulletin136 Rev.M HorizontalSidewall HSW1Deflector RecessedPendent (ModelFPShown) Upright Pendent VerticalSidewall Conventional Application Quickresponsesprinklersareusedinfixedfireprotec- tionsystems:Wet,Dry,DelugeorPreaction.Caremustbe exercisedthattheorificesize,temperaturerating,deflector styleandsprinklertypeareinaccordancewiththelatest publishedstandardsoftheNationalFireProtectionAsso- ciationortheapprovingAuthorityHavingJurisdiction. Quickresponsesprinklersareintendedforinstallationas specifiedinNFPA13.Quickresponsesprinklersandstan- dardresponsesprinklersshouldnotbeintermixed. Bu l l e t i n 1 3 6 Re v . M Listings&Approvals 1.ListedbyUnderwritersLaboratories,Inc.(UL) 2.ListedbyUnderwriters’LaboratoriesofCanada(ULC) 3.CertifiedbyFMApprovals 4.LossPreventionCouncil(LPC,UK) 5.NYCBS&ANo.587-75-SA 6.MeetsMIL-S-901CandMIL-STD167-1 7.VerbandderSchadenversicherer(VdS,Germany) 8.NYCMEA258-93-E ULListingCategory Sprinklers,Automatic&Open QuickResponseSprinkler ULGuideNumber VNIV ProductDescription ReliableModelsF1FRandF1FRRecessedSprinklersare quickresponsesprinklerswhichcombinethedurabilityofa standardsprinklerwiththeattractivelowprofileofadecorative sprinkler. TheModelsF1FRandF1FRRecessedautomaticsprinklers utilizea3.0mmfrangibleglassbulb.Thesesprinklershave demonstratedresponsetimesinlaboratorytestswhichare fivetotentimesfasterthanstandardresponsesprinklers.This quickresponseenablestheModelF1FRandF1FRRecessed sprinklerstoapplywatertoafiremuchfasterthanstandard sprinklersofthesametemperaturerating. Theglassbulbconsistsofanaccuratelycontrolledamount ofspecialfluidhermeticallysealedinsideapreciselymanu- facturedglasscapsule.Thisglassbulbisspeciallycon- structedtoprovidefastthermalresponse.Thebalanceof partsaremadeofbrass,copperandberylliumnickel. Atnormaltemperatures,theglassbulbcontainsthefluid inboththeliquidandvaporphases.Thevaporphasecan beseenasasmallbubble.Asheatisapplied,theliquidex- pands,forcingthebubblesmallerandsmallerastheliquid pressureincreases.Continuedheatingforcestheliquidto pushoutagainstthebulb,causingtheglasstoshatter, openingthewaterwayandallowingthedeflectortodistrib- utethedischargingwater. Patents:USPatentNo.6,374,920Appliesto ModelF1FRVerticalSidewallSprinklers. ModelF1FRQuickResponseUpright,Pendent&ConventionalSprinklers InstallationWrench:ModelDSprinklerWrench InstallationData: ModelF1FRQuickResponseRecessedPendentSprinkler InstallationWrench:ModelGFR1SprinklerWrench InstallationData: 2. Nominal Orifice Thread Size KFactor Sprinkler Height Approval(1) Organizations SprinklerIdentification Number(SIN)USMetric 1 2 (15mm)1 2 NPT(R½)5.6802.2 (56mm)1,2,3,4,5,7,8R3615 17 32 (20mm)3 4 NPT(R¾)8.01152.3 (58mm)1,2,3,8R3612 7 16 (11mm)1 2 NPT(R½)4.2602.2 (56mm)1,2,8R3613 3 8 (10mm)1 2 NPT(R½)2.8402.2 (56mm)1,2,8R3611 10mmR3 8 4.26056mm4,7R3614 (1)Refertoescutcheondatatableforapprovalsanddimensions. Upright Pendent Conventional SprinklerType KFactor Sprinkler Height Approval Organization SprinklerIdentification Number(SIN) USMetric SSUSSP 1 2 (15mm)StandardOrificewith 1 2 NPT(R 1 2)Thread5.6802.2 (56mm)1,2,3,4,5,6,7R3625R3615 17 32 (20mm)LargeOrificewith 3 4 NPT(R¾)Thread8.01152.3 (58mm)1,2,3,4,7,8R3622R3612 7 16 (17mm)SmallOrificewith 1 2 NPT(R 1 2)Thread4.2602.2 (56mm)1,2,8R3623R3613 3 8 (10mm)SmallOrificewith 1 2 NPT(R 1 2)Thread2.8402.2 (56mm)1,2,8R3621R3611 10mmOrificeXLHwithR3 8 Thread4.26056mm4,6,7R3624R3614 Conventional–InstallinUprightorPendentPosition 10mmOrificeXLHwithR3 8 Thread 15mmStandardOrificewith 1 2 NPT(R 1 2)Thread 20mmLargeOrificewith¾NPT(R¾)Thread 4.2 5.6 8.0 60 80 115 56mm 56mm 58mm —— 4,6,7 4,7 R3674 R3675 R3672 TheequipmentpresentedinthisbulletinistobeinstalledinaccordancewiththelatestpertinentStandardsoftheNationalFireProtectionAssociation,FactoryMutualResearch Corporation,orothersimilarorganizationsandalsowiththeprovisionsofgovernmentalcodesorordinanceswheneverapplicable. ProductsmanufacturedanddistributedbyReliablehavebeenprotectinglifeandpropertyforover80years,andareinstalledandservicedbythemost highlyqualifiedandreputa- blesprinklercontractorslocatedthroughouttheUnitedStates,Canadaandforeigncountries. TheReliableAutomaticSprinklerCo.,Inc. (800)431–1588SalesOffices (800)848–6051SalesFax (914)668–3470CorporateOffices www.reliablesprinkler.com InternetAddress Manufacturedby Revisionlinesindicateupdatedornewdata Recycled Paper EG.PrintedinU.S.A.7/05P/N9999970027 OrderingInformation Specify: 1.SprinklerModel 2.SprinklerType 3.OrificeSize 4.DeflectorType 5.TemperatureRating 6.SprinklerFinish 7.EscutcheonType 8.EscutcheonFinish(whereapplicable) Note:WhenModelF1FRRecessedsprinklersare ordered,thesprinklersandescutcheonsarepackaged separately. TemperatureRatings Classification Sprinkler Temperature Max.Ambient Temp. Bulb Color°C°F Ordinary Ordinary Intermediate Intermediate High (1) 57 68 79 93 141 135 155 175 200 286 100 F(38 C) 100 F(38 C) 150 F(66 C) 150 F(66 C) 225 F(107 C) Orange Red Yellow Green Blue (1)Notavailableforrecessedsprinklers. Escutcheon Model ApprovalsAdjustment “A” Dimension FaceofFitting toCeilingor WallDimension F1 1,2,4,8 MaxRecess MinRecess 1 1 2 (38.1mm) 3 4 (19.1mm) 3 16 -15 16 (5mm-24mm) F2 1,2,3,4,5,7,8 MaxRecess MinRecess 1 1 2 (38.1mm) 15 16 (24mm) 3 16 -11 16 (5mm-17mm) FP Push-on/ Thread-off 1,2MaxRecessed 7 16 (11mm)112 (38.1mm) 1,2MinRecessed 15 16 (24mm)1 (25.4mm) EscutcheonData Finishes (1)(2) Installation Quickresponsesprinklersareintendedforinstallationas specifiedinNFPA13.Quickresponsesprinklersandstan- dardresponsesprinklersshouldnotbeintermixed. TheModelF1FRRecessedQuickResponseSprinklersareto beinstalledasshown.TheModelF1orF2Escutcheonsillus- tratedaretheonlyrecessedescutcheonstobeusedwiththe ModelF1FRSprinklers.Theuseofanyotherrecessedescutch- eonwillvoidallapprovalsandnegateallwarranties. WheninstallingModelF1FRSprinklers,usetheModelDSprin- klerWrench.WheninstallingModelF1FRRecessedPendentor SidewallSprinklers,usetheModelGFR1SprinklerWrench.Any othertypeofwrenchmaydamagethesesprinklers. Glassbulbsprinklershaveorangebulbprotectorstominimize bulbdamageduringshipping,handlingandinstallation.RE- MOVETHISPROTECTIONATTHETIMETHESPRINKLER SYSTEMISPLACEDINSERVICEFORFIREPROTECTION.Re- movaloftheprotectorsbeforethistimemayleavethebulbvul- nerabletodamage.RASCOwrenchesaredesignedtoinstall sprinklerswhencoversareinplace.REMOVEPROTECTORS BYUNDOINGTHECLASPBYHAND.DONOTUSETOOLS TOREMOVETHEPROTECTORS. SprinklerTypes StandardUpright StandardPendent Conventional Sidewall(Vertical,HorizontalHSW1) RecessedPendent RecessedHorizontalSidewallHSW1 (1)Otherfinishesandcolorsareavailableonspecialorder. Consultthefactoryfordetails. (2)FMApprovalsislimitedtobronzeandbrass,chromeorblack platedfinishesonly. (3)FPPush-on/Thread-offescutcheon StandardFinishes SprinklerEscutcheon Bronze ChromePlated WhitePolyesterCoated Brass ChromePlated (3) WhitePainted (3) SpecialApplicationFinishes SprinklerEscutcheon BrightBrass BlackPlated BlackPaint OffWhite SatinChrome BrightBrass BlackPlated BlackPaint OffWhite SatinChrome Maintenance TheModelsF1FRandF1FRRecessedSprinklers shouldbeinspectedquarterlyandthesprinklersystem maintainedinaccordancewithNFPA25.Donotclean sprinklerswithsoapandwater,ammoniaoranyother NoDimensionalFigureforFP cleaningfluids.Removedustbyusingasoftbrushorgen- tlevacuuming.Removeanysprinklerwhichhasbeen painted(otherthanfactoryapplied)ordamagedinany way.Astockofsparesprinklersshouldbemaintainedto allowquickreplacementofdamagedoroperatedsprin- klers.Priortoinstallation,sprinklersshouldbemaintained intheoriginalcartonsandpackaginguntilusedtomini- mizethepotentialfordamagetosprinklersthatwould causeimproperoperationornon-operation. OFFICE/MANUFACTURING FACILITY• 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE• 800.786.5266 www.tolco.com 66 www.tolco.com Revision 5/24/2001 ™ ® a brand of Max Rec. Load Lbs. Rod For Service Temps Approx. Size650°F750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11⁄4 8000 7140 360 11⁄2 11630 10370 510 www.tolco.com Revision 8/15/2005 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 98 - Rod Stiffener Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Component of State of California OSHPD Approved Seismic Restraints System OFFICE/MANUFACTURING FACILITY• 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE• 800.786.5266 www.tolco.com 84 www.tolco.com Revision 5/24/2001 ™ ® a brand of www.tolco.com Revision 5/24/2001 Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21⁄2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31⁄8 25⁄8 400 11 3/4 3/8 8mm or 10mm 31⁄8 21⁄2 400 11 1 3/8 8mm or 10mm 33⁄8 25⁄8 400 12 11⁄4 3/8 8mm or 10mm 33⁄4 27⁄8 400 13 11⁄2 3/8 8mm or 10mm 37⁄8 27⁄8 400 14 2 3/8 8mm or 10mm 41⁄2 3 400 15 21⁄2 3/8 10mm 55⁄8 41⁄8 600 27 3 3/8 10mm 57⁄8 4 600 29 31⁄2 3/8 10mm 73⁄8 51⁄4 600 34 4 3/8 10mm 73⁄8 5 1000 35 5 1/2 12mm 91⁄8 61⁄4 1250 66 6 1/2 12mm 101⁄8 63⁄4 1250 73 8 1/2 12mm 131⁄8 83⁄4 1250 136 www.tolco.com Revision 1/24/2007 OFFICE/MANUFACTURING FACILITY• 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE• 800.786.5266 www.tolco.com 62 Size Range — 3/8" thru 3/4" rod Function — For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals — Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number, rod size and finish Note — Do not over tighten set screw. Fig. 68 - Wide Throat Top Beam “C” Clamp w/Locknut Dimensions • Weights Rod Max. Rec. Approx. Size Load Lbs. Wt./100 3/8 400 34 1/2 500 50 5/8 600 53 3/4 800 86 IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY ® REGISTERED TRADEMARK OF VICTAULIC – © COPYRIGHT 2006 VICTAULIC – PRINTED IN U.S.A. – SKU #WCAS-67PJUX 1539 REV F 10.03 United States • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e-mail: pickvic@victaulic.com Canada • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada@victaulic.com Europe • Phone: 32-9-381-1500 • Fax: 32-9-380-4438 • e-mail: viceuro@victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e-mail: viceuro@victaulic.be Central and South America • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vical@victaulic.com Australasia • Phone: 86-21-54253300 • Fax: 86-21-54253671 • e-mail: vicap@victaulic.com FireLock®Fittings PRODUCT DESCRIPTION FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. DIMENSIONS T C to E C to E C to E No. 001No. 003 No. 002No. 006 C to E C to E Fitting Size No. 001 90° Elbow No. 003 45° Elbow No. 002 Straight Tee No. 006 Cap Nominal Diameter Inches/mm Actual Outside Diameter Inches/mm C to E Inches mm Aprx. Weight Each Lbs./kg C to E Inches mm Aprx. Weight Each Lbs./kg C to E Inches mm Aprx. Weight Each Lbs./kg Thickness “T” Inches mm Aprx. Weight Each Lbs./kg 11/4 1.660 ––––––0.820.3 3242.4 ––––––210.1 11/2 1.9002.751.21.750.92.752.00.820.4 4048.3700.5454.1700.9210.2 22.3752.751.72.001.82.752.40.880.6 5060.3700.8510.8701.1220.3 21/2 2.8753.003.12.252.23.003.60.881.0 6573.0761.4571.0761.6220.5 76.1 mm 3.0003.003.302.252.4–––– 76.1761.5571.1–––– 33.5003.384.02.503.13.385.30.881.2 8088.9861.8641.4862.4220.5 108 mm 4.2504.005.73.005.14.007.5–– 108.01022.6762.31023.4–– 44.5004.006.73.005.64.008.71.002.4 100114.31023.0762.51023.9251.1 55.5634.8812.63.258.34.8815.71.004.1 125141.31245.7833.81247.1251.9 159 mm 6.2505.5012.63.509.23.5017.9–– 158.81405.7894.21408.0–– 66.6255.5018.33.5011.75.5022.71.005.9 150168.31408.3895.314010.3252.7 88.6256.8125.54.2520.46.9438.71.1312.7 200219.117311.61089.317617.6295.8 ULCUL® FM See Victaulic publication 10.01 for details. Patented 2 FireLock® Fittings 10.03 FLOW DATA MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12 Fitting Coating: Orange enamel •Optional: Hot dipped galvanized Fitting Size Frictional Resistance Equivalent Feet/meters of Straight Pipe Nominal Diameter Inches/mm Actual Outside Diameter Inches/mm 90° Elbow No. 001 45° Elbow No. 003 Straight Tee No. 002 BranchRun 11/4 1.6601.50.83.71.5 3242.40.50.21.10.5 11/2 1.9002.21.15.52.2 4048.30.70.31.70.7 22.3753.51.88.53.5 5060.31.10.52.61.1 21/2 2.8754.32.210.84.3 6573.01.30.73.31.3 76.1 mm 3.0004.52.311.04.5 76.11.40.73.41.4 33.5005.02.613.05.0 8088.91.50.84.01.5 108 mm 4.2506.43.215.36.4 108.02.00.94.72.0 44.5006.83.416.06.8 100114.32.11.04.92.1 55.5638.54.221.08.5 125141.32.61.36.42.6 159 mm 6.2509.44.925.09.6 158.82.91.57.62.9 66.62510.05.025.010.0 150168.33.01.57.63.0 88.62513.05.033.013.0 200219.14.01.510.14.0 † The flow data listed is based upon the pressure drop of Schedule 40 pipe. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.02 PRODUCT DESCRIPTION Style 005 FireLockTM Rigid Coupling with Vic-PlusTM Gasket System Patented 10.02-1D SIZE Nominal Inches Actual mm Max. Work. Press. § PSI*/kPa Max. End Load Lbs.*/N Allow. Pipe End Sep. † In./mm @ Bolt/Nut No. - Size Inches/mm Dimensions Inches/mm Aprx. Wgt. Ea. Lbs./kgXYZ 1 ¹⁄₄3507550.05 2 - ³⁄₈ ✕2 2.754.501.881.2 42,4241333701,2701141480,5 1 ¹⁄₂3509900.05 2 - ³⁄₈ ✕2 3.004.751.881.2 48,3241344151,2761211480,5 235015500.07 2 - ³⁄₈ ✕2 ¹⁄₂3.505.251.881.6 60,3241369001,7891331480,7 2 ¹⁄₂35022700.07 2 - ³⁄₈ ✕2 ¹⁄₂4.005.751.881.9 73,02413101101,71021461480,9 76,1 mm 35024750.07 2 - ³⁄₈ ✕2 ¹⁄₂4.135.751.881.9 2413110101,71051461480,9 335033650.07 2 - ³⁄₈ ✕2 ¹⁄₂4.636.131.882.1 88,92413149851,71181561481,0 435055650.16 2 - ³⁄₈ ✕2 ¹⁄₂5.757.252.133.1 114,32413247704,1146184541,4 108,0 mm 30042550.16 2 - ³⁄₈ ✕2 ¹⁄₂5.637.252.133.1 2068189404,1143184541,4 530072900.16 2 - ¹⁄₂ ✕2 ³⁄₄6.889.002.134.5 141,32068324454,1175229542,0 133,0 mm 30064950.16 2 - ¹⁄₂ ✕2 ³⁄₄6.639.002.134.5 2068289004,1168229542,0 139,7 mm 30071250.16 2 - ¹⁄₂ ✕2 ³⁄₄6.889.002.134.8 2068317154,1175229542,2 6300103400.16 2 - ¹⁄₂ ✕2 ³⁄₄8.0010.002.135.0 168,32068460204,1203254542,3 159,0 mm 30092000.16 2 - ⁵⁄₈ ✕4 ¹⁄₄7.6310.002.135.5 2068409554,1194254542,5 165,1 mm 30099550.16 2 - ¹⁄₂ ✕2 ³⁄₄8.1510.002.135.5 2068442954,1207254542,5 8300175250.19 2 - ⁵⁄₈ ✕4 ¹⁄₄10.5013.132.6311.3 219,12068780004,8267334675,1 * @ § † Refer to notes on page 2. DIMENSIONS Rated for wet and dry sprinkler systems at 350 PSI (2413 kPa) for 1 ¹⁄₄ - 4" (42,4 - 114,3 mm) sizes and 300 PSI (2068 kPa) for 4 ¹⁄₄ - 8" (108,0 - 219,1 mm) sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expan- sion, contraction or angular deflection. X Y Z FireLock™ Style 005 rigid coupling has a unique, pat- ented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. The FireLock couplings provide rigidity for valve connections, fire mains and long straight runs. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle- pad design permits assem- bly by removing one nut/ bolt and swinging the housing over the gasket. This reduces components to handle during assembly; speeds and eases installa- tion on pipe grooved to Victaulic specifications. Style 005 FireLock cou- plings with the Vic- PlusTM Gasket System are designed and rec- ommended for use ONLY on fire protection systems. Vic-Plus Gasket System: Victaulic® now offers a gas- ket system which requires no field lubrication. The Vic-PlusTM System (patent pending) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. THE LOSS PREVENTION COUNCIL VdS § LPC and VdS Approved, see notes on page 2. Victaulic® World Headquarters • P.O. Box 31, Easton, PA 18044-0031 • 4901 Kesslersville Rd., Easton, PA 18040 • 1-800-PICK VIC • FAX: 610/250-8817 • www.victaulic.com 1538 Rev.E10/00® Registered Trademark of Victaulic© Copyright 1999 VictaulicPrinted in U.S.A. 10.90 - 2 MATERIAL SPECIFICATIONS Housing: Ductile iron conform- ing to ASTM A-395, grade 65- 45-15, and ASTM A-536, grade 65-45-12. Housing Coating: Orange enamel ❏Optional: Hot dipped galva- nized Gasket: ❏Grade “E” EPDM - Type A Vic-Plus Gasket System † (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler ser- vices up to the rated working pressure using the Grade “E” Type A Vic-Plus Gasket System, requiring no field lubrication. For dry services, Victaulic continues to recommend the use of Grade “E” Type A FlushSeal® Vic-Plus Gasket System. Contact Victaulic for details. Bolts/Nuts: Heat treated car- bon steel, zinc electroplated to ASTM B-633; Track head bolt conforming to ASTM A-183 minimum tensile 110,000 PSI (758340 kPa); Flanged hex nut conforming to ASTM A-563, Grade A. † Standard gasket and FlushSeal gasket approved for dry pipe systems to –40°F (–40°C). Supplemental lubricant is rec- ommended for services installed at or continuously operating below 0°F (-18°C). Victaulic continues to recom- mend the use of FlushSeal gaskets for dry services. NOTES * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accor- dance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 ¹⁄₂ times the figures shown. † For field installation only. FireLock Style 005 couplings are essentially rigid and do not accommodate expansion/contraction. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar (175 PSI). WARNING: Piping systems must always be depressurized and drained before attempting disassembly and removal of any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 10.02-2A Rated Working PressureRated Working Pressure Pipe Schedule Size InchesULULCFM Pipe Schedule Size InchesULULCFM 51 ¹⁄₄ - 3175175175 EZ 4300300300 10, 40 1 ¹⁄₄ - 43503503506175175175 5 - 8300300300SF1 ¹⁄₄ - 4300300300 BLT1 ¹⁄₄ - 2300300300Super 401 ¹⁄₄ - 2300300300 DF 1 ¹⁄₄ - 4300300300TL1 ¹⁄₄ - 2300300300 6175175175WLS1 ¹⁄₄ - 2300300300 DT1 ¹⁄₄ - 2300300300XL/XL-II1 ¹⁄₄ - 3300300300 EL1 ¹⁄₄ - 2300300300 NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe. 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. BLT refers to Listed/Approved steel sprinkler pipe manufactured by American Tube Company. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. DT refers to Listed/Approved Dyna Thread steel sprinkler pipe manufactured by American Tube Company. EL refers to Listed/Approved Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed/Approved EZ-Flow steel sprinkler pipe manufactured by Northwest Pipe & Casing Co. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. SL refers to Listed/Approved steel sprinkler pipe manufactured by Western Tube and Conduit Corporation. Super 40/XL refers to Listed/ Approved Super 40 or Super XL steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. WLS refers to Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. XL/XL-II refers to Listed/Approved XL or XL-II steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a “holefinder” locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. MATERIAL SPECIFICATIONSHousing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade “E” EPDM EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are s ervices for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a l isting of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. 11.02_1 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS JOB OWNERCONTRACTORENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I STYLES 920 AND 920NSTYLE 920 CROSS DIMENSIONS GROOVED OUTLET W ZY V Size Style No. Max. Work PressureDimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg 2 × ½ (a)920N 5001.502.002.53 —1.615.352.753.1 —5015345038.1516441136701.5 ¾ (a)920N 5001.501.972.53 —1.615.352.753.1 —20345038.1506441136701.5 1 (a)920N 5001.501.852.53 —1.615.352.753.0 —25345038.1476441136701.4 1 ¼ (a) †920N 5001.752.052.753.001.615.353.003.53.2 32345044.552707641136761.71.5 1 ½ (a) †920N 5001.752.032.753.121.615.353.253.63.2 40345044.552707941136831.71.5 2 ½ × ½ (a)920N 5001.502.212.74 —91.825.642.753.0 —6515345038.1567046143701.4 ¾ (a)920N 5001.502.182.74 —1.825.642.753.0 —20345038.1557046143701.4 1 (a)920N 5001.502.062.74 —1.825.642.752.9 —25345038.1527046143701.4 1 ¼ † (a)920N 5001.752.303.003.251.826.293.003.53.2 32345044.558768346160761.71.5 1 ½ † (a)920N 5002.002.283.003.251.826.263.253.63.3 40345050.858768346159831.71.6 76.1× ½ (a)920 3001.502.222.75 —2.256.463.183.9 —15206538.1567057164811.8 ¾ (a)920 3001.502.192.75 —2.256.463.183.9 —20206538.1567057164811.8 1 (a)920 3001.502.072.75 —2.256.463.183.8 —25206538.1537057164811.7 1 ¼ (a)920 5001.752.303.003.311.926.293.003.53.2 32345044.558768449160761.61.5 1 ½ (a)920 5002.002.283.003.311.926.293.253.53.3 40345050.858768449160831.61.5 3 × ½ (a)920N 5001.502.523.05 —2.286.152.753.4 —8015345038.1647858156701.6 ¾ (a)920N 5001.502.493.05 —2.286.152.753.4 —20345038.1637858156701.6 1 (a)920N 5001.502.383.06 —2.286.152.753.3 —25345038.1617858156701.6 1 ¼ (a) †)920N 5001.752.553.253.562.286.153.003.83.7 32 (b345044.565839058156761.81.8 1 ½ (a) †920N 5002.002.783.503.562.286.153.254.13.8 40 (b)345050.871899058156831.91.8 2 (a)920N 5002.502.753.503.562.286.753.884.94.6 50345063.570899058172992.32.1 3 ½ × 2 920N 5002.50 ——3.752.446.723.88 —3.8 9050345063.59562171991.8 TABLE CONTINUED ON PG. 3 FEMALE THREADED OUTLET T W ZY V IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm 11.02_2 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I STYLES 920 AND 920NSTYLE 920 CROSS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Size Style No. Max. Work PressureDimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 4 165.1× 1 920 5001.503.884.56 —3.799.342.758.0 —25345038.19911696237703.6 1 ¼ 920 5001.754.435.13 —3.799.343.258.4 —32345044.511313096237833.8 1 ½ (a) †920 5002.004.415.13 —3.799.343.258.4 —40345050.811213096237833.8 2 (a) †920 5002.504.385.13 —3.799.343.888.5 —50345063.511113096237993.9 2 ½ †920 5002.754.015.13 —3.6310.514.638.67.6 65345069.9110130922671183.93.4 76.1 mm920 5002.754.015.135.213.6310.514.638.67.6 345069.9110130132922671183.93.4 3 (a) †920 5003.504.315.505.133.6310.515.3110.28.4 80345088.9110140130922671354.63.8 4 (a) †920 5004.503.815.755.383.6310.516.2510.58.4 1003450114.397146137922671594.83.8 8 × 2 (a) †920 5002.755.446.196.254.8112.424.5011.611.6 20050345069.91381571591223161145.35.3 2 ½ (a) †920 5002.755.076.196.194.8112.424.5011.611.6 65345069.91291571571223161145.35.3 76.1 mm920 5002.75 ——6.254.8112.424.56 —11.6 345069.91591223161165.3 3 (a) †920 5003.505.316.506.504.8112.425.3112.611.6 80345088.91351651651223161355.75.3 4 (a) †920 5004.504.816.756.384.8112.426.2515.312.5 1003450114.31221711621223161596.95.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order. DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm 11.02_5 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I STYLES 920 AND 920NSTYLE 920 CROSS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 900N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. CV Values Values for flow of water at +60°F/+16°C are shown in the table below. SIZE Equivalent Length Feet/meter of PipeSIZE Equivalent Length Feet/meter of Pipe Nominal Diameter In./mm Actual Out. Dia. In./mmGrooved Female Threaded Nominal Diameter In./mm Actual Out. Dia. In./mmGrooved Female Threaded ½ 0.840 —2.022.3759.010.5 1521.30.65060.32.73.2 ¾ 1.050 —4.02 ½ 2.87511.012.5 2026.71.26573.03.43.8 11.315—5.033.50013.515.5 2533.71.58088.94.14.7 1 ¼ 1.6605.56.044.50020.022.0 3242.41.71.8100114.36.16.7 1 ½ 1.9007.08.0 4048.32.12.4 Formulas for CV Values: ΔP = Q2 Cv 2 Where: Q = Flow (GPM) ΔP = Pressure Drop (psi) Cv = Flow CoefficientQ = Cv x ΔP SizeCVSizeCVSizeCV Nominal Size Inches/mm Actual Outside Diameter Inches/mmValues Nominal Size Inches/mm Actual Outside Diameter Inches/mmValues Nominal Size Inches/mm Actual Outside Diameter Inches/mmValues ½ 0.840 17 1 ¼ 1.660 45 2 ½ 2.875 1351521.33242.46573.0 ¾ 1.050 21 1 ½ 1.900 60 33.5002002026.74048.38088.9 11.31525 22.375100 44.5004002533.75060.3100114.3 1 2 Exaggerated for Clarity 11.02_6 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I STYLES 920 AND 920NSTYLE 920 CROSS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS APPROVED PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publi- cation. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run SizeOutlet SizePipeRated Working Pressures – psi/kPa Nominal Size Inches/mm Actual Outside Diameter Inches/mmInches/mmScheduleULULCFM 21/2 - 62.875 - 6.625 All10, 40 400400400 65 - 15073.0 - 168.3275527552755 21/2 - 42.875 - 4.500 AllDF 300300300 65 - 10073.0 - 114.3206520652065 21/2 - 42.875 - 4.500 AllSF 300300300 65 - 10073.0 - 114.3206520652065 66.6253, 410 300300250 150168.3206520651724 66.6253,430, 40 300300300 150168.3206520652065 88.62521/210, 40 400 ——200219.12755 88.6253,410 300 —250 200219.120651724 88.6253,430, 40 300 —300 200219.120652065 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. 11.02_7 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I STYLES 920 AND 920NSTYLE 920 CROSS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS R IPS CARBON STEEL PIPE – HOLE CUT PRODUCTS VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY ® REGISTERED TRADEMARK OF VICTAULIC – © COPYRIGHT 2003 VICTAULIC – PRINTED IN U.S.A.3355 REV B 10.52 Victaulic Company of America • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e-mail:pickvic@victaulic.com Victaulic Company of Canada • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada@victaulic.com Victaulic Europe • Phone:32-9-381-1500 • Fax: 32-9-380-4438 • e-mail: viceuro@victaulic.be Victaulic America Latina • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vical@victaulic.com Victaulic Asia Pacific • Phone: 65-6235-3035 • Fax: 65-6235-0535 • e-mail: vicap@victaulic.com Style 922 FireLock® Outlet-T PRODUCT DESCRIPTION The Style 922 Outlet-T provides a convenient method of incorporating 1/2,3/4, and 1" (15, 20 and 25 mm) outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76,1 mm (32 to 76,1 mm) piping systems, Style 922 outlets are UL/ULC Listed, LPC, Vds/FM approved for branch connections on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi (2068 kPa) and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* It is supplied with a clear, rust inhibitive coating. Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. DIMENSIONS ULCUL® FM See Victaulic publication 10.01 for details. VdS THE LOSS PREVENTION COUNCIL V T W Y Z Nominal Size inches/mm Hole Diameter +0.06/+1,5 -0.00/-0,0 Dimensions – inches/millimeters Approx. Weight Each lbs/kg Run ✕ Branch FPT†T*VWYZ 11/4 X 1/2 13/16 1.301.831.103.872.561.0 32X1530,233,046,527,998,365,00,45 11/4 X 3/4 13/16 1.281.831.103.872.561.1 32X2030,232,546,527,998,365,00,50 11/4 X113/16 1.522.181.103.872.561.2 32X2530,238,655,427,998,365,00,54 11/2 X 1/2 13/16 1.421.951.224.082.561.2 40X1530,236,149,531,0103,665,00,54 11/2 X 3/4 13/16 1.401.951.224.082.561.2 40X2030,235,649,531,0103,665,00,54 11/2 X113/16 1.642.301.224.082.561.3 40X2530,241,758,431,0103,665,00,59 2X 1/2 13/16 1.662.191.464.602.561.3 50X1530,242,255,637,1116,865,00,59 2X 3/4 13/16 1.642.191.464.602.561.4 50X2030,241,755,637,1116,865,00,64 2X1 13/16 1.882.541.464.602.561.5 50X2530,247,864,537,1116,865,00,68 21/2 X 1/2 13/16 1.912.441.715.402.561.6 65X1530,248,562,043,4137,265,00,73 21/2 X 3/4 13/16 1.892.441.715.402.561.6 65X2030,248,062,043,4137,265,00,73 21/2 X113/16 2.132.791.715.402.561.6 65X2530,254,170,943,4137,265,00,73 76,1 mm X 1/2 13/16 1.912.441.715.502.561.6 76,1X1530,248,562,043,4139,765,00,73 76,1 mm X 3/4 13/16 1.892.441.715.502.561.6 76,1X2030,248,062,043,4139,765,00,73 76,1 mm X1 13/16 2.132.791.715.502.561.7 76,1X2530,254,170,943,4139,765,00,80 † Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinklers, etc., should be verified as suitable for use with this Vic- taulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). 2 Style 922 FireLock® Outlet-T 10.52 PERFORMANCE MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-395, grade 65-45-15, and ASTM A-536, grade 65-45-12 Gasket: •Grade “E” EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade “E” Type A Gasket System. Bolts/Nuts:Heat treated carbon steel zinc electroplated track head bolt with a minimum tensile strength of 110,000 psi (758340 kPa). Flanged hex nut, zinc electroplated. Nominal Size Inches/mm Equivalent Length of 1" Pipe Feet/meters 11/4 X18.5 32X252,6 11/2 X18.5 40X252,6 2X18.5 50X252,6 2 ¹⁄₂X18.5 65X252,6 76,1 mmX18.5 76,1X252,6 This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 8 Grooved End Fittings 07.01 No. 50 and No. 51 Concentric/Eccentric Reducers Steel (except as noted) Nominal Size Inches/mm No. 50No. 51 Nominal Size Inches/mm No. 50No. 51 E to E Inches mm Approx. Wgt. Ea. Lbs./kg E to E Inches mm Approx. Wgt. Ea. Lbs./kg E to E Inches mm Approx. Wgt. Ea. Lbs./kg E to E Inches mm Approx. Wgt. Ea. Lbs./kg 11/4 X 3/4 +1.9––4X33.00* d3.24.00 d3.5 32X20+0.9––100X80761.41021.6 X1+1.9––X 31/2 3.00 d2.910.008.0 X25+0.9––X90761.32543.6 11/2 X 3/4 +1.4––5X24.009.011.005.2 40X20+0.6––125X501024.12792.4 X12.50* d0.88.504.5X 21/2 11.0011.011.0010.8 X25640.42162.0X652795.02794.9 X 11/4 2.50* d1.0––X34.00 d5.511.0011.1 X32640.5––X801022.52795.0 2X3/4 2.50* d0.99.002.0X43.50 d4.35.00 d12.0 50X20640.32290.9X100891.91275.4 X12.50* d0.79.002.36X14.00* d5.011.5014.5 X25640.32291.0150X251022.32926.6 X 11/4 2.50* d1.29.004.6X 11/2 +5.5++ X32640.52292.1X40+2.5++ X 11/2 2.50* d1.09.004.6X24.00* d6.611.5014.5 X40640.52292.1X501023.02926.6 21/2 X 3/4 +1.3+3.3X 21/2 4.00* d6.411.5014.2 65X20+0.6+1.5X651022.92926.4 X19.503.69.503.5X34.00* d6.45.50 d15.0 X252411.52411.6X801022.91406.8 X 11/4 2.50* d3.39.50+X44.00 d6.55.50 d17.0 X32641.5241+X1001022.91407.7 X 11/2 2.50* d3.69.503.7X54.00 d6.45.50 d17.0 X40641.62411.7X1251022.91407.7 X22.50 d3.99.504.38X 21/2 16.00*7.912.0026.1 X50641.82412.0200X654063.630511.8 3X3/4 +1.5+4.5X35.00 d9.312.0022.0 80X20+0.7+2.0X801274.230510.0 X12.50* d1.39.504.8X45.00 d10.412.0023.0 X25640.62412.2X1001274.830510.4 X 11/4 +3.0+4.8X55.00 d11.612.0023.0 X32+1.4+2.2X1251275.230510.4 X 11/2 2.50* d5.19.505.1X65.00 d11.96.00 d24.0 X40642.32412.3X1501275.415210.9 X22.50* d1.63.50 d6.010X46.00 d19.713.0032.0 X50640.7892.7250X1001528.933014.5 X 21/2 2.50* d1.83.50 d7.0X5+34.3+34.6 X65640.8893.2X125+15.6+15.7 X76,1 mm 2.50 d2.1––X66.00 d20.013.0036.9 641.0––X1501529.133016.7 31/2 X32.50 d2.09.507.0X86.00 d22.07.0 d21.6 90X80640.92413.2X20015210.01789.8 4X13.00* d3.010.006.512X4+44.014.0048.0 100X25761.42542.9300X100+20.035621.8 X 11/4 +4.6––X67.00 d24.614.0050.0 X32+2.1––X15017811.235622.7 X 11/2 10.006.910.008.1X87.00 d52.014.0053.5 X402543.12543.7X20017823.635624.3 X23.00* d2.44.00 d3.3X107.00 d39.014.0057.0 X50761.11021.5X25017817.735625.9 X 21/2 3.00* d2.74.00 d3.4 Table continued on page 9. See notes on page 9.X65761.21021.5 E to E E to E