Loading...
HomeMy WebLinkAboutF10-0084 Gouriex Res Lionshead CentreTheReliableAutomaticSprinklerCo.,Inc.,103FairviewParkDrive,Elmsford,NewYork10523 Bulletin176 Rev.A Bu l l e t i n 1 7 6 Re v . A ModelF1ResSprinklersengineeredforthelowestflows tomeettheminimumdesigndensityof.05gpm/ft2 Types: 1.F1Res49Pendent 2.F1Res49RecessedPendent/F1 3.F1Res49RecessedPendent/FP 4.F1Res49CCPPendent 5.F1Res58Pendent 6.F1Res58RecessedPendent/F1 7.F1Res58RecessedPendent/FP 8.F1Res58CCPPendent 9.F1Res44&58HSW 10.F1Res44&58HSWRecessedHSW/F2 11.F1Res44SWC 12.F1Res76Pendent 13.F1Res76RecessedPendent/F1 14.F1Res76RecessedPendent/FP 15.F1Res76CCPPendent Listings&Approvals 1.ListedbyUnderwritersLaboratoriesInc.and ULCertifiedforCanada(cULus) 2.NYCMEA258-93-E ProductDescription ModelF1ResPendentsprinklers(Figs.1,2,3&4) combineexcellentdurability,highsensitivityglass-bulb andlowprofiledecorativedesign. The3mmglass-bulbpendentsprinklerspermitthe efficientuseofresidentialwatersuppliesforsprinkler coverageinresidentialfireprotectiondesign. ThelowflowF1Ressprinklersarespecially engineeredforfastthermalresponsetomeetthe sensitivefireprotectionapplicationneedsofthelatest residentialmarketstandards(UL1626Standard * Uponfireconditions,risingheatcausesasprinkler’s heat-sensitiveglass-bulbtoshatter,releasingthe waterwayforwaterflowontothedeflector,evenly distributingthedischargedwatertocontrolafire. F1Res49,58&76 RecessedPendent/F1 F1Res49,58&76 RecessedPendent/FP F1Res49,58&76 CCPPendent ULListingCategory ResidentialAutomaticSprinkler ULGuideNumber VKKW Patents USPatentNo.6,516,893appliestothe ModelF1Res49&58PendentSprinklers TechnicalData: •ThermalSensor:Nominal3mmglass-bulb •SprinklerFrame:BrassCasting •Sprinklers’PressureRating:175psi FactoryHydrostaticallyTestedto500psi •ThreadSize:½”NPT(R1/2) •K-Factor:4.9(Actual)-F1Res49PendentSprinkler 5.8(Actual)-F1Res58Pendent&HSWSprinkler 7.6(Actual)-F1Res76PendentSprinkler 4.4(Actual)-F1Res44HSWSprinkler •Density:Minimum0.10gpm/ft2 F1Res44&58 RecessedHSW/F2 ModelF1 ResidentialSprinklersfor DesignDensityof.10gpm/ft2 F1Res44SWC *Effectivedate7/12/02 Application ModelF1ResSprinklersareusedforResidentialFire ProtectionaccordingtoUL1626Standard*.Besure thatorificesize,temperaturerating,deflectorstyleand sprinklertypeareinaccordancewiththelatest publishedstandardsofTheNationalFireProtection Associationortheapprovingauthorityhaving jurisdiction. WhenusingF1ResidentialSprinklersforsystems designtoNFPA13DorNFPA13R,uselistedareaof coverageandminimumflowandpressurerequirements showninBulletin135. ForsystemsdesignedtoNFPA13,useinformationin thisbulletin.Thenumberofdesignsprinklersshallbethe mosthydraulicallydemandingsprinklersasrequiredby NFPA13.Flowsandpressurescannotbebelowthe baselineflowsandpressurers. NFPA13 ForresidentialsprinklersystemsdesignedtoNFPA13, aminimumdensityof0.1gpm/ft2 mustbeprovidedover the“designarea”thatincludesthefour(4)hydraulically mostdemandingsprinklersfortheactualcoverage areasbeingprotectedbythe4sprinklers.Theminimum requireddischargefromeachofthefourmost hydraulicallydemandingsprinklersshallbethe greater ofthefollowing: 1.TheflowratesgivenintheReliableResidential SprinklerTechnicalBulletinsreferencedinTableA forNFPA13Dand13Rasafunctionoftemperature ratingandmaximumallowablecoveragearea(for actualcoverageareaslessthanorbetweenthose indicatedintherespectivetechnicalbulletin,itis requiredtousetheminimumrequiredflowforthe nextlargestcoveragearea);or 2.Aminimumdischargedensityof0.1gpm/ft2 appliedoverthe“designarea”consistingofthefour mosthydraulicallydemandingsprinklersforthe actualcoverageareasbeingprotectedbythefour sprinklers.Themaximumdimensionoftheactual coverageareacannotbeanygreaterthanthe maximumcoverageareaindicatedinthetechnical bulletinsreferencedinTableA. DesignNote:UsingtheAs =SxLmethodto determinethesprinklerprotectionareaofcoverage inaccordancewithNFPA13,applythe0.1gpm/ft2 densitytothisareatodeterminetheminimum requiredflow.Comparethisflowtotheminimum 0.05gpm/ft2 cULusListedflowfortheappropriate coverageareainthetechnicalbulletinforthe specificresidentialsprinkler.Iftheflowstatedinthe technicalbulletinislessthanthecalculated0.1 gpm/ft2 densityflowrequired,the.1densityflow mustthenbeusedintheequationQ=K P ,solving forP,toestablishtheminimumrequiredpressure usingthesprinklerK-factor.Note:Inmanycases thelistedflowofindividualresidentialsprinklers mayexceedtherequiredminimum0.05gpm/ft2 density.Reliablehasavailableresidentialsprinklers withlargerK-factors(K=5.8andK=7.6)thatwill providelowerpressuredemandsfor0.1gpm/ft2 densitiesinNFPA13residentialapplications. ExampleNo.1 RoomSize=12ftx20ft(3.6mx6.1m) CoverageArea=12x20=240ft2 (22.3m2) Flow@0.10gpm/ft2 density=240x0.10=24gpm UsinganF1Res49PendentSprinkler,K=4.9 Pressure=(24/4.9)2 =24psi(1.65bar) Thebaselineflowfora20ftx20ft(6.1mx6.1m) coverageareausingthebaselinedensityof0.05 gpm/ft2 willbe20gpm@16.7psi(75.7L/min@1.14 bar).Therefore,theminimumflowrequiredis24gpm@ 24psi(90.8L/min@1.65bar). ExampleNo.2 RoomSize=8ftx20ft(2.4mx6.1m) CoverageArea=8x20=160ft2 (14.9m2) Flow@0.10gpm/ft2 density=160x0.10=16gpm UsinganF1Res49PendentSprinkler,K=4.9 Pressure=(16/4.9)2 =10.7psi(0.74bar) Thebaselineflowfora20ftx20ft(6.1mx6.1m) coverageareausingthebaselinedensityof0.05 gpm/ft2 willbe20gpm@16.7psi(75.7L/min@1.14 bar).Therefore,theminimumflowrequiredis20gpm@ 16.7psi(75.7L/min@1.14bar). ExampleNo.3 RoomSize=10ftx16ft(3.0mx4.91m) CoverageArea=10x16=160ft2 (14.9m2) Flow@0.10gpm/ft2 density=160x0.10=16gpm UsinganF1Res76PendentSprinkler,K=7.6 Thebaselineflowfora16ftx16ftcoverageareais21 gpm@7.6psi(79.5L/min@0.52bar).Therefore,the minimumflowandpressureis21gpm@7.6psi(79.5 L/min@0.52bar). ExampleNo.4 RoomSize=14ftx18ft(4.3mx5.5m) CoverageArea=14x18=252ft2 (23.6m2) Flow@0.10gpm/ft2 density=252x0.10=25.2gpm (94.6L/min) UsinganF1Res76PendentSprinkler,K=7.6 Pressure=(252/7.6)2 =11psi(0.76bar) Thebaselineflowandpressureofan18ftx18ft coverageareais21gpm@7.6psi(79.5L/min@0.52 bar).Therefore,theminimumflowandpressureis25.2 gpm@11psi(94.6L/min@0.76bar). Ingeneralresidentialsprinklersrequire flowsandpressuresaslistedfor0.05 densitiestoachievetheproperspraypattern sotheflowsandpressuresat0.05densityare thebaselineflowsandpressures.Flowsand pressuresbelowthelisted0.05densityshall notbeused. 2. ModelF1Res49,58&76Pendent ModelF1Res49,58&76 RecessedPendent/F1/F2 Fig.1 Fig.2 F1escutcheon,3 4 (19mm)adjustment 3. Installation ModelsF1Ressprinklersaretobeinstalledas shown.ModelF1,F2andFPEscutcheons,illustrated herewith,aretheonlyrecessedescutcheonstobeused withModelF1Ressprinklers.Useofanyother recessedescutcheonwillvoidallapprovalsand warranties.ForinstallingModelF1ResPendent sprinklersuseonlytheModelDsprinklerWrench;for installingModelsF1ResRecessedPendent,CCP sprinklersuseonlytheModelGFR2sprinklerwrench; forinstallingModelF1ResrecessedHSWsprinklers useonlytheModelGFR2Sprinklerwrench.Useof wrenchesotherthanthosespecifiedmaydamage thesesprinklers. Note:A‘leaktight”sprinklerjointcanbeobtainedwith thefollowingtorque: •¾”NPT(R3/4)–14-20ft-lbs(19-27.1N-m) •½”NPT(R1/2)–8-18ft-lbs(10.8–24.4N-m) Donottightensprinklersovermaximum recommendedtorque.Itmaycauseleakageor impairmentofthesprinklers. Note:Seeescutcheontablefordimensions. 4. Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)F C F C 1 2 NPT (R1 2) 716"(11)155 175 68 79 175(12)100 150 38 66 4.92.25(57) Max.Sprinkler Spacing ft(m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6)13(49)7.0(0.48) R3516 14x14(4.3x4.3)13(49)7.0(0.48) 16x16(4.9x4.9)13(49)7.0(0.48) 18x18(5.5x5.5)17(64.3)12.0(0.83) 20x20(6.1x6.1)20(75.7)16.7(1.14) Deflector-to-ceiling Maximum1 (25mm)to4 (100mm) Type Adjustment Inch(mm) “A” Inch(mm) Faceoffittingto ceiling Inch(mm) F1 3 4 (19.0)Min.=3 4 (19.1) Max.=11 2 (38.1) 3 16 -15 16 (4.7-24.0) F2 1 2 (12.7)Min.=15 16 (23.8) Max.=11 2 (38.1) 3 16 -1116 (4.7-17.4) Escutcheon*,F1orF2,Data: *Note: Max.Sprinkler Spacing ft(m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6)15(57)9.4(0.65) R3516 14x14(4.3x4.3)16(60.5)10.6(0.73) 16x16(4.9x4.9)17(64.3)12.0(0.83) 18x18(5.5x5.5)19(72)15.0(1.0) 20x20(6.1x6.1)22(83.2)20.2(1.4) *Deflector-to-ceiling Maximum4 (100mm)to8 (203mm) *Note:TheF1Res49pendentandrecessedpendent residentialsprinklerscanbeinstalledperNFPA13in beamedceilingsmeetingthefollowingcriteria: 1.Maximumbeamdepth=7 (178mm) 2.Beamspacingatorgreaterthan7.5ft.(2.3m)oncenter. TechnicalData:F1Res49PendentandRecessedPendent Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)F C F C ½NPT (R½) 1 2"(13)155 175 68 79 175(12)100 150 38 66 5.82.25(57) Max.Sprinkler Spacing ft(m) Flow gpm(Lpm) Pressure psi(bar) Ceiling-to- Deflector Inch(mm) Sprinkler Identification Number(SIN) 12x12(3.6x3.6)16(61)7.6(0.53) 1-4 (25-100)R3513 14x14(4.3x4.3)16(61)7.6(0.53) 16x16(4.9x4.9)16(61)7.6(0.53) 18x18(5.5x5.5)19(72)10.8(0.75) 20x20(6.1x6.1)22(83.3)14.4(1.0) TechnicalData:F1Res58PendentandRecessedPendent **Baselineflowsandpressuresfor0.05density **Baselineflowsandpressuresfor0.05density **Calculatefora.10densitybutinnocase gobelowthebaselineflows&pressures 5. ModelF1Res49,58&76 CCPPendent ModelF1Res49,58&76 RecessedPendent/FP FPpush-on/thread-off escutcheon Fig.4Fig.3 NOTE:TheF1Res76willusea1"x¾"reducer. TechnicalData:F1Res76PendentandRecessedPendent Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)F C F C 3 4 NPT (R3 4) 17 32"(13.5)155 175 68 79 175(12)100 150 38 66 7.62.25(57) Max.Sprinkler Spacing ft(m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6)217.6(0.53) R7618 14x14(4.3x4.3)217.6(0.53) 16x16(4.9x4.9)217.6(0.53) 18x18(5.5x5.5)217.6(0.53) 20x20(6.1x6.1)239.2(0.63) Type Adjustment Inch(mm) “A” Inch(mm) Faceoffittingto ceiling Inch(mm) F1 3 4 (19.0)Min.=3 4 (19.1) Max.=11 2 (38.1) 3 16 -15 16 (4.7-24.0) F2 1 2 (12.7)Min.=15 16 (23.8) Max.=11 2 (38.1) 3 16 -1116 (4.7-17.4) *Baselineflowsandpressuresfor0.05density *Calculatefora.10densitybutinnocase gobelowthebaselineflows&pressures 6. Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)F C F°C F C ½NPT (R½) 716 "(11)1556813557175(12)100384.9 2.25 (57) Max.Sprinkler Spacing ft(m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6)13(49)7.0(0.48) R3516 14x14(4.3x4.3)13(49)7.0(0.48) 16x16(4.9x4.9)14(53)8.2(0.56) 18x18(5.5x5.5)18(68.1)13.5(0.93) 20x20(6.1x6.1)20(75.7)16.7(1.14) “A” CoverAdjustment Inch(mm) “B” CCPHeight Inch(mm) 1 2 (12.7)15 16 (24) 3 16 (4.7)3 4 (19) CCPOptionsData: FPPosition “A” Inch(mm) Max.Recessed 716 (11) Min.Recessed 15 16 (24) FPData“A”: TechnicalData:F1Res49CCPPendentandRecessedPendent/FP Note:SprinklersshowninFig.3andFig.4arenot suitableforinstallationinceilingswhichhave positivepressureinthespaceabove. Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)F C F°C F C NPT (R½)½"(13)1556813557175(12)100385.82.25(57) Max.Sprinkler Spacing ft(m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6)16(61)7.6(0.53) R3513 14x14(4.3x4.3)16(61)7.6(0.53) 16x16(4.9x4.9)16(61)7.6(0.53) 18x18(5.5x5.5)19(72)10.8(0.75) 20x20(6.1x6.1)22(83.3)14.4(1.0) TechnicalData:F1Res58CCPPendentandRecessedPendent/FP Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating CCP Assembl yTemp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)F C F°C F C ¾NPT (R3/4) 17 32" (13.5) 155 175 68 79 13557175(12)100 150 38 66 7.6 2.25 (57) Max.Sprinkler Spacing ft(m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6)217.6(0.53) R7618 14x14(4.3x4.3)217.6(0.53) 16x16(4.9x4.9)217.6(0.53) 18x18(5.5x5.5)228.4(0.58) 20x20(6.1x6.1)2510.8(0.74) TechnicalData:F1Res76CCPPendentandRecessedPendent/FP *Baselineflowsandpressuresfor0.05density *Baselineflowsandpressuresfor0.05density *Baselineflowsandpressuresfor0.05density *Calculatefora.10densitybutinnocase gobelowthebaselineflows&pressures ModelF1Res44&58HSW ModelF1Res44&58 RecessedHSW/F2 F2escutcheon,12 (13mm) adjustment Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)F C F C ½NPT (R½) 3 8"(10)155 175 68 79 175(12)100 150 38 66 4.42.45(62) Type Adjustment Inch(mm) FaceofFitting towall Inch(mm) F2 1 2 (13)3 16 -1116 (4.7-17.4) Escutcheon,F2,Data: TechnicalData:F1Res44HSW&HSW/F2 Max.Sprinkler Spacing ft(m) “A” Ceiling-to- Deflector Inch(mm) SprinklerTemp. Rating F(C) Flow gpm (Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6) 4-6 (101-152) 155(68)175(79)12(45.4)7.5(0.52) R3531 14x14(4.3x4.3)155(68)175(79)14(53.0)10.2(0.71) 16x16(4.9x4.9)155(68)175(79)16(60.6)13.3(0.92) 16x18(4.9x5.5)155(68)175(79)18(68.1)16.8(1.16) 18x18(5.5x5.5)155(68)175(79)19(72.0)18.7(1.29) 16x20(4.9x6.1)155(68)175(79)23(87.1)27.4(1.89) 12x12(3.6x3.6) 6-12 (152-305) 155(68)175(79)14(53.0)10.2(0.71) 14x14(4.3x4.3)155(68)175(79)16(60.6)13.3(0.92) 16x16(4.9x4.9)155(68)175(79)17(64.4)15.0(1.04) 16x18(4.9x5.5)155(68)175(79)20(75.7)20.7(1.43) 16x20(4.9x6.1)155(68)175(79)23(87.1)27.4(1.89) *Baselineflowsandpressuresfor0.05density *Calculatefora.10densitybutinnocase gobelowthebaselineflows&pressures 7. 8. ModelF1Res44SWC Fig.5 Max.Sprinkler Spacing ft(m) “A” Ceiling-to- Deflector Inch(mm) Flow gpm (Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6) 4-6 (101-152) 13(49.2)8.7(0.60) R3531 14x14(4.3x4.3)14(53.0)10.2(0.71) 16x16(4.9x4.9)17(64.3)15.0(1.1) 16x18(4.9x5.5)19(71.8)18.7(1.13) 16x20(4.9x6.1)23(87.1)27.4(1.89) 12x12(3.6x3.6) 6-12 (152-305) 14(52.9)10.2(0.71) 14x14(4.3x4.3)15(56.7)11.7(0.81) 16x16(4.9x4.9)18(68.1)16.8(1.16) 16x18(4.9x5.5)20(75.6)20.7(1.43) *Baselineflowsandpressuresfor0.05density Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating CoverTemp. Rating Max. Pressure psi (bar) Max. AmbientTemp.K Factor Sprinkler Length Inch (mm)F C F°C F C ½NPT (R½) 3 8"(10)1556813557175(12)100384.42.45(62) TechnicalData:F1Res44SWC *Calculatefora.10densitybutinnocase gobelowthebaselineflows&pressures Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)F C F C ½NPT (R½) 1 2"(13)155 175 68 79 175(12)100 150 38 66 5.82.45(62) Type Adjustment Inch(mm) FaceofFitting towall Inch(mm) F2 1 2 (13)3 16 -1116 (4.7-17.4) Escutcheon,F2,Data: TechnicalData:F1Res58HSW&HSW/F2 Max.Sprinkler Spacing ft(m) “A” Ceiling-to- Deflector Inch(mm) SprinklerTemp. Rating F(C) Flow gpm (Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12x12(3.6x3.6) 4-6 (101-152) 155(68)175(79)16(60.6)7.6(0.53) R3533 14x14(4.3x4.3)155(68)175(79)18(68.2)9.7(0.67) 16x16(4.9x4.9)155(68)175(79)21(79.5)13.2(0.91) 16x18(4.9x5.5)155(68)175(79)25(94.7)18.6(1.28) 16x20(4.9x6.1)155(68)175(79)29(109.8)25(1.73) 12x12(3.6x3.6) 6-12 (152-305) 155(68)175(79)22(83.3)14.4(1.0) 14x14(4.3x4.3)155(68)175(79)22(83.3)14.4(1.0) 16x16(4.9x4.9)155(68)175(79)26(98.4)20.1(1.39) 16x18(4.9x5.5)155(68)175(79)31(117.4)28.6(1.97) *Baselineflowsandpressuresfor0.05density 9. *Calculatefora.10densitybutinnocase gobelowthebaselineflows&pressures OrderingInformation Specify: 1.SprinklerModel 2.SprinklerType 3.TemperatureRating 4.SprinklerFinish 5.EscutcheonFinish StandardFinishes SprinklerF1,F2,FPEscutcheons Bronze ChromePlated WhitePolyesterCoated Brass BrightChromePlated WhitePainted SpecialApplicationFinishes SprinklerF1,F2,Escutcheons BrightBrass BlackPlated BlackPaint OffWhite SatinChrome BrightBrass BlackPlated BlackPaint OffWhite SatinChrome Finishes(1) (1)Otherfinishesandcolorsareavailableonspecialorder. Consultfactoryfordetails. 10. Maintenance ModelF1Res49,F1Res58&F1Res76Sprinklers shouldbeinspectedquarterly,andthesprinklersystem maintainedinaccordancewithNFPA25,13,13D,and 13R.Donotcleansprinklerwithsoapandwater,Ammonia oranyothercleaningfluids.Removedustbyusingasoft brushorgentlevacuuming.Removeanysprinklerwhich hasbeenpainted(otherthanfactoryapplied)ordamaged inanyway.Astockofsparesprinklersshouldbe maintainedtoallowquickreplacementofdamagedor operatedsprinklers.Priortoinstallation,sprinklersshould remainintheoriginalcartonsandpackaginguntilused. Thiswillminimizethepotentialfordamagetosprinklersthat couldcauseimproperoperationornon-operation. ModelF1RES49Residential SprinklerSpecifications ModelF1Res49&58Pendent Sprinklersshallbe[cULusListed][NewYorkCityMEA Approved(258-93-E)]lowflowresidentialpendent sprinklersengineeredtoprovideaminimumdesign densityof0.10gpm/ft2 overthelistedcoveragearea. Listedflowsasspecifiedbythemanufacturer’stechnical datasheetsaretobeused.Residentialsprinklersshallbe installedinconformancewiththemanufacturer’s installationguidelinesandtheapplicableinstallation standard.Wherependentresidentialsprinklersare installedunderslopedceilingshavingapitchofupto[4/12] [8/12],thesprinklersshallbelistedforsuchuse. Deflector-to-ceilingdistancelistingshallbe1”to8” maximum.Sprinklerframeanddeflectorshallbeofbronze frameconstructionhavinga½”NPTthread.Waterseal assemblyshallconsistofaTeflon-coatedBellevillespring washerandtop-loadedextrudedcupwith3mmglassbulb containingnoplasticparts,andhavingatemperature ratingof[155 F(68 C)][175 F(79 C)].Sprinklersshall haveanominalK-factorof4.9&5.8.Standardfinish: [Bronze][Chrome-plated][WhitePolyester][Specialfinish– specify].ResidentialpendentsprinklersshallbeReliable ModelF1Res49&58,SINR3516&R3513(Bulletin135). ModelF1Res49&58RecessedPendent/F1, ModelF1Res49&58RecessedPendent/F2, ModelF1Res49&58RecessedPendent/FP Sprinklersshallbe[cULusListed][NewYorkCityMEA Approved(258-93-E)]lowflowresidentialrecessed pendentsprinklersengineeredtoprovideaminimum designdensityof0.10gpm/ft2 overthelistedcoveragearea. Listedflowsasspecifiedbythemanufacturer’stechnical datasheetsaretobeused.Residentialsprinklersshallbe installedinconformancewiththemanufacturer’sinstallation guidelinesandtheapplicableinstallationstandard.Where pendentresidentialsprinklersareinstalledundersloped ceilingshavingapitchofupto[4/12][8/12],thesprinklers shallbelistedforsuchuse.Deflector-to-ceilingdistance listingshallbe1”to8”maximum.Sprinklerframeand deflectorshallbeofbronzeframeconstructionhavinga½” NPTthread.Watersealassemblyshallconsistofa Teflon-coatedBellevillespringwasherandtop-loaded extrudedcupwith3mmglassbulbcontainingnoplastic parts,andhavingatemperatureratingof[155 F(68 C)] [175 F(79 C)].SprinklersshallhaveanominalK-factorof 4.9(70).Standardfinish:[Bronze][Chrome-plated][White Polyester][Specialfinish–specify].Recessedescutcheon assemblyshallbeasteel,two-pieceescutcheon[with½” adjustment(ModelF2)][with¾”adjustment(ModelF1)][of push-onandthreadoffdesignwith½”adjustment(Model FP)].Standardfinishshallbe[brass][brightchrome][white painted].Residentialrecessedpendentsprinklersshallbe Reliable[ModelF1Res49&58RecessedPendent/F1] [ModelF1Res49&58RecessedPendent/F2][ModelF1 Res49&58RecessedPendent/FP]SINR3516&R3513 (Bulletin135). ModelF1Res49&58CCPPendent(Concealed) Sprinklersshallbe[cULusListed][NewYorkCityMEA Approved(258-93-E)]lowflowresidentialconcealed sprinklersengineeredtoprovideaminimumdesign densityof0.10gpm/ft2 overthelistedcoveragearea. Listedflowsasspecifiedbythemanufacturer’stechnical datasheetsaretobeused.Residentialsprinklersshall beinstalledinconformancewiththemanufacturer’s installationguidelinesandtheapplicableinstallation standard.Wherependentresidentialsprinklersare installedunderslopedceilingshavingapitchofupto [4/12][8/12],thesprinklersshallbelistedforsuchuse. Sprinklerframeanddeflectorshallbeofbronzeframe constructionhavinga½”NPTthread.Waterseal assemblyshallconsistofaTeflon-coatedBelleville springwasherandtop-loadedextrudedcupwith3mm glassbulbcontainingnoplasticparts,andhavinga temperatureratingof155 F(68 C).Coverplate assemblyshallconsistofabrasscoverplateandcopper alloyretainerflange.Methodofattachingthecoverplate tothesprinklercupshallbeapush-onandthread-off designallowinga½”coverplateadjustment.Cover platetemperatureratingshallbe135 F(57 C).Aplastic protectivecapshallbeprovidedandfactoryinstalled insidethesprinklercuptoprotectthesprinklerfrom damage,whichcouldoccurduringconstructionbefore thecoverplateisinstalled.Standardcoverplatefinish: [White][CustomColor–specify].].Concealedpendent sprinklersshallbeReliableModelF1Res49&58CCP, SINR3516&R3513(Bulletin135). 11. ModelF1Res44&58HorizontalSidewall Sprinkler Sprinklersshallbe[cULusListed][NewYorkCityMEA Approved(258-93-E)]lowflowresidentialhorizontal sidewallsprinklersengineeredtoprovideaminimum designdensityof0.10gpm/ft2 overthelistedcoverage area.Listedflowsasspecifiedbythemanufacturer’s technicaldatasheetsaretobeused.Residential sprinklersshallbeinstalledinconformancewiththe manufacturer’sinstallationguidelinesandtheapplicable installationstandard.Wherehorizontalsidewall residentialsprinklersareinstalledunderslopedceilings havingapitchofupto[4/12][8/12],thesprinklersshall belistedforsuchuse.Sprinklerframeanddeflectorshall beofbronzeframeconstructionhavinga½”NPTthread. WatersealassemblyshallconsistofaTeflon-coated Bellevillespringwasherandtop-loadedextrudedcup with3mmglassbulbcontainingnoplasticparts,and havingatemperatureratingof[155 F(68 C)][175 F (79 C)].SprinklersshallhaveanominalK-factorof5.8. Standardfinish:[Bronze][Chrome-plated][White Polyester][Specialfinish–specify].Residentialhorizontal sidewallsprinklersshallbeReliableModelF1Res58, SINR3513(Bulletin135). ModelF1Res44&58Recessed HorizontalSidewallSprinkler UsedescriptionfortheModelF1Res58horizontal sidewallsprinklerwiththefollowingmodifications: Replace“horizontalsidewallsprinkler”with“recessed horizontalsprinkler.”Add:Recessedescutcheon assemblyshallbeasteel,two-pieceescutcheonwith½” adjustment(ModelF2).Standardfinishshallbe [brass][brightchrome][whitepainted][Specialfinish– specify].Residentialrecessedhorizontalsidewall sprinklersshallbeReliableModelF1Res58/F2,SIN R3513(Bulletin135). ModelF1Res76Pendent Sprinklersshallbe[cULusListed]lowflowresidential pendentsprinklersengineeredtoprovideaminimum designdensityof0.10gpm/ft2 overthelistedcoveragearea. Listedflowsasspecifiedbythemanufacturer’stechnical datasheetsaretobeused.Residentialsprinklersshallbe installedinconformancewiththemanufacturer’sinstallation guidelinesandtheapplicableinstallationstandard. Sprinklerframeanddeflectorshallbeofbronzeframe constructionhavinga¾”NPTthread.Watersealassembly shallconsistofaTeflon-coatedBellevillespringwasherand machinedcupwith3mmglassbulbcontainingnoplastic parts,andhavingatemperatureratingof[155 F(68 C)] [175 F(79 C)].SprinklersshallhaveanominalK-factorof 7.6.Standardfinish:[Bronze][Chrome-plated][White Polyester][Specialfinish–specify].Residentialpendent sprinklersshallbeReliableModelF1Res76,SINR7618 (Bulletin135). ModelF1Res76RecessedPendent/F1, ModelF1Res76RecessedPendent/F2, ModelF1Res76RecessedPendent/FP Sprinklersshallbe[cULusListed]lowflowresidential recessedpendentsprinklersengineeredtoprovidea minimumdesigndensityof0.10gpm/ft2 overthelisted coveragearea.Listedflowsasspecifiedbythe manufacturer’stechnicaldatasheetsaretobeused. Residentialsprinklersshallbeinstalledinconformance withthemanufacturer’sinstallationguidelinesandthe applicableinstallationstandard.Sprinklerframeand deflectorshallbeofbronzeframeconstructionhavinga ¾”NPTthread.Watersealassemblyshallconsistofa Teflon-coatedBellevillespringwasherandmachined cupwith3mmglassbulbcontainingnoplasticparts,and havingatemperatureratingof[155 F(68 C)][175 F (79 C)].SprinklersshallhaveanominalK-factorof7.6. Standardfinish:[Bronze][Chrome-plated][White Polyester][Specialfinish–specify].Recessed escutcheonassemblyshallbeasteel,two-piece escutcheon[with½”adjustment(ModelF2)][with¾” adjustment(ModelF1)][ofpush-onandthreadoffdesign with½”adjustment(ModelFP)].Standardfinishshallbe [brass][brightchrome][whitepainted].Residential recessedpendentsprinklersshallbeReliable[ModelF1 Res76RecessedPendent/F1][ModelF1Res76 RecessedPendent/F2][ModelF1Res76Recessed Pendent/FP]SINR7618(Bulletin135). ModelF1Res76CCPPendent(Concealed) Sprinklersshallbe[cULusListed]lowflowresidential concealedsprinklersengineeredtoprovideaminimum designdensityof0.10gpm/ft2 overthelistedcoveragearea. Listedflowsasspecifiedbythemanufacturer’stechnical datasheetsaretobeused.Residentialsprinklersshallbe installedinconformancewiththemanufacturer’sinstallation guidelinesandtheapplicableinstallationstandard. Sprinklerframeanddeflectorshallbeofbronzeframe constructionhavinga¾”NPTthread.Watersealassembly shallconsistofaTeflon-coatedBellevillespringwasherand machinedcupwith3mmglassbulbcontainingnoplastic parts,andhavingatemperatureratingof155 F(68 C). Coverplateassemblyshallconsistofabrasscoverplate andcopperalloyretainerflange.Methodofattachingthe coverplatetothesprinklercupshallbeapush-onand thread-offdesignallowinga½”coverplateadjustment. Coverplatetemperatureratingshallbe135 F(57 C).A plasticprotectivecapshallbeprovidedandfactoryinstalled insidethesprinklercuptoprotectthesprinklerfrom damage,whichcouldoccurduringconstructionbeforethe coverplateisinstalled.Standardcoverplatefinish:[White] [CustomColor–specify].].Concealedpendentsprinklers shallbeReliableModelF1Res76CCP,SINR7618(Bulletin 135). Reliable...ForCompleteProtection Reliableoffersawideselectionofsprinklercomponents.Followingaresomeofthemany precision-madeReliableproductsthatguardlifeandpropertyfromfirearoundtheclock. •Automaticsprinklers •Flushautomaticsprinklers •Recessedautomaticsprinklers •Concealedautomaticsprinklers •Adjustableautomaticsprinklers •Dryautomaticsprinklers •Intermediatelevelsprinklers •Opensprinklers •Spraynozzles •Alarmvalves •Retardingchambers •Drypipevalves •Acceleratorsfordrypipevalves •Mechanicalsprinkleralarms •Electricalsprinkleralarmswitches •Waterflowdetectors •Delugevalves •Detectorcheckvalves •Checkvalves •Electricalsystem •Sprinkleremergencycabinets •Sprinklerwrenches •Sprinklerescutcheonsandguards •Inspectorstestconnections •Sightdrains •Balldripsanddrumdrips •Controlvalveseals •Airmaintenancedevices •Aircompressors •Pressuregauges •Identificationsigns •Firedepartmentconnection TheequipmentpresentedinthisbulletinistobeinstalledinaccordancewiththelatestpertinentStandardsoftheNationalFireProtectionAssociation,FactoryMutualResearch Corporation,orothersimilarorganizationsandalsowiththeprovisionsofgovernmentalcodesorordinances,wheneverapplicable. ProductsmanufacturedanddistributedbyRELIABLEhavebeenprotectinglifeandpropertyforover80years,andareinstalledandservicedbythemosthighlyqualifiedandreputable sprinklercontractorslocatedthroughouttheUnitedStates,Canadaandforeigncountries. Manufacturedby (800)431-1588SalesOffices (800)848-6051SalesFax (914)829-2042CorporateOffices www.reliablesprinkler.com InternetAddress Revisionlinesindicateupdatedornewdata. EG.PrintedinU.S.A.05/08P/N9999970322 Recycled Paper