HomeMy WebLinkAboutB03-0341.PDF _ �— - '1 - .
�
��� C�L l�
I I I �� ��
� � i � y .
�
i
" F �, i'�j ��
�� � � t �
d�,.�- " �;,� (�j ,
��� ^ �✓
PROVIDE ADEQUATE DEPTH FOR NEW AND �� � �
EX15T1NG CEIUNG FIXTURES,IJGHTS, AND ALL
EQUIPMENT-MAINTAIN MINIMUM 7'0"CEIt1NG TOP CHANNEL-SECURE TO FLOOR
HEIGHT FROM FLOOR BELOW STRUCTURE ABOVE CONSTRUCT IN ACCORDANCE WITH CONSTRUCT IN ACCORDANCE WITH A R C H I T E � �'
EXISTING FLOOR STRUCTURE EXISfIN�FLOOR SfRUCTURE PROVIDE SUP JOINT TO ALLOW UL ASSEMBLY X528 (SIM) - 2 HOI,R RATED UL ASSEMBLY N501 (SIMj - 2 HOUR RATED
FOR STRUCNRE DEFLECiION
� �
� 3/4" ST�L HAT CHANNElS ' 1 1/2"STEEL HAT CHANNELS � v �
SECURE O STRUCTIJRE ABOVE HANG FROM STRUCTURE ABOVE °_' � o
� 3 5/8"STEEL S1UDS C�? 16"O C - — � e P �
SECURE TO ADIACENT WAl1S 5/8" GNSUM 80ARD
AND STRUCTURE ABOVE AS REQUIRED � - n� � V
1 5/S" STEE!iTUD CONCRETE FLOOR(EXISTiNG) �� o a —°v
3 5/8" STEEL STUDS AT 16"O C �� � ` t � �
5/8"GYPSUM BOARD n STEEL TUBE C�LUNIN(EXISTING) '''�,�' � �•�
5/8 FR GYPSUM BOARD 1/2" FR GYP;UM BOARD r� FIRE SEAL � :� �, � °'
CEILING B CEILING A
STEEL BEAM EXISTING) -�''�' `�'
1/2" FR GYP;UM BOARD ( �
SOUND PROOFING INSUCATION � = o
5/8" FR GYP;UM BOARD 2 LAYERS 5/8° FR GYPSUM BOARQ �..:.,� —° m
CONSTRUCT IN ACCORDANCE WITH � $
UL ASSEMBLY U419- 1 HOUR RATED NO. 18 SWGSTEEL WIRE SPACED � � �';� '' ''' � °
, AT 24 O C YERT STEEL CLIPS ATTACHED AT 2 0 OC � o 0
--- � ;. °� v
BASE CHANNEL-SECURE TO FLOOR CORNER BEA�S \ = X �
STRUCTURE BELOW CORNER BEADS � � O �
�d n: w
T ical New Cei I i n s T ical New Partition T ical Steel Col t�mn VVra T ical Steel Beam Wra
„ _ , „ 4 m � ONTRACTOR
SCALE: � — �-0 SCALE: ���_ ��-0�� SC�1LE � �,2��_ ��-0�� SC�LE: � ��2„T ,,�„
.
� sTRUC � u � � `
DECK �� �f�� '
�!�' � �
C�.t�e�" ' �
l c� ..� �,
� �� �
BEDROOM 1 � �t� �
�
105 ���y�,�..
GENERAL NOTES � �� '� �s�
ALL DEMOL1110N REQUIRED FOR PLUMBING AND OTHER
S� L � �9 � SCA � � ,
U1111TY ACCESS REMOVAL,OR MODIFlCATION IS NOT � ___ �- �
NECESSARILY 5HOWN,NOR ARE All RELATED MINOR � CLOSET � Town of Vail r�`��„�
AREAS OF PATCH OR REPAIR NFCESSARILY INDICATED
GENERAL CONTRACTOR SHALL REMOVE FJ0S11NG WORK CLOSET 2 i 106 ��� � p9
AS REQUIRED TO PERFORM INDICATED WORK AND SHALL �O9 ���v '��
rx ;.S'.��;' .., a�J
� Au�N
- ( REPAIR ALL DISfURBED SURFACES TO MATCH ADIACENT F IN I S H SC H E D U LE
, UNDISTURBED AREAS WORK INCLUDES ANY REQUIRED � � '
ACCESS ABOYE OR BELOW THIS FLOOR AS WELL BEDfi00M 2 � � ��, �
COORDINATE WORK IN OTHER AREAS WITH THE BUILDING I I A��� � # ROOM FLDOR CEILING WALLS COMMEt�fTS �
MANAGMENT WALL AND FLOOR FlNISHES SHALL BE OH � � •�
REMOVED BACK TO THE MINIMtJM EXTENT REflUIRED TO — 1 Ol ENTRY WOOD GYP BD -CEILING A GYP BD -PAINT
MAI�MINIMUM VISUAL IMPACE ON MEETING OF NEW AND LIVING ROOM � \ O 102 DINING AREA WOOD GYP BD -CEILING A GYP BD -PAINT �
EXISTING WORK � BATH 1 � � � �
�� 1 0 4 � �� O 103 KITCHEN WOOD GYP BD -CEILING B GYP BD -PAIM �
REMOVE WALLS,EQUIPMENT, FIXTURES,DOORS AND �FP � � �07 104 LIVING ROOM CARPET GYP BD -CEILING A GYP BD -PAINT
FRAMES, FLOORS,ETC AS DENOTED ON PLANS
' WITH DASHED LINES. REPAIR REMAINING WORK TO MATCH 105 B�DROOM 1 CARPET GYP BD -CEILING A GYP BD -PAIM
SURROUNDING FINISHES TO REMAIN WHERE EXPOSED o � �o BELOW 106 CLOSEt 1 CARPEf TEX1l1RE ON CONC STRUCTURE GYP BD -PAINT
BY DEMOU110N �I �
107 BATH 1 TILE GYP BD -CEILING B GYP BD -PAIM
All DESIGNS,CONSTRUCTtON,MATERIALS,AND LINEN 108 BEDROOM 2 CARPET GYP BD -CEILING A GYP BD -PAIM
WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE gATH 2 � �3 NEW ARCHED OPENING —��
CODES AND REGULATIONS. � � �O � 109 CLOSET 2 CARPET TEXTURE ON CONC STRUCTURE GYP 8D -PAINT _
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL � 110 BATH 2 TILE GYP BD -CEILING B GYP BD -PAINT ,
CONSTRUCTION MEANS,METHODS,TECHNIQUES,s�ouENCES, 3 +a2" HIGH WALL 3 � 111 BEDROOM 3 CARPET GYP BD -CEILING A GYP BD -PAIIVT � � � � � �
AND PROCEDURES AS THEY RELATE TO THE WORK ON � A� t A�.� � 112 CLOSEf 3 CARPET TEXRIRE ON CONC STRUCTURE GYP BD -PAINT !
THIS PROJECT. � . r,o DLSCRIP'170N v��rc ;
� — --- — --- EGRESS SfAIR 113 LINEN CARPET TEXTURE ON CONC STRUCTURE GYP BD -PAINT �
CONTRACTOR SHALL PROVIDE ALL MECHANICAL, �TEEL FLOOR BEAM _ ° STFEL FLO�R BEAM __`
ELECTRICAI,PLUMBING, FIRE PROTECTION,AND 2 CL�SET 3 � �� � � , A For Perm�t 10 09 0 ;
A N Y O T N E R M I S C D R A W I N G S A N D E N G I N E E R I N G N E C E S S A R Y A� � � � �2 I - - _ ; D I N I N G A R E A ( � D O O R S�H E D U L E `
FOR COMPLETION OF THIS PROJE�T 1 I I ENTRY
B�DROOM 3 _ � 01 � KITCHEN A � �02 � � 101 �
CONTRACTOR SHALL VEWFY ALL EXISTING CONDI110NS AND � � �O3 O ' I I � # ROOM DOOR SIZE TYPE STYLE COMMEMS
DRAWING DIMENSIONS PRIOR TO COMMENCING ANY WORK. > > � � � �
�
ANY INCONSISfENQES W1TH THE DRAWINGS SHALL BE � -}- - — - - �� 101 BATH 1 2'4" x(NOTE A) HINGED MATCH EX(ST
REPORTED TO THE ARCHITECT IN WRITING PRIOR � L - - - - - � � � I
TO COMMENCING WORK
CONTI2ACTOR SHALL VERIFY THAT EXISTING STRUCfURE The
� CAN SUPPORT ATTACHMENT OF ALL NEW WORK NOTE A - MATCH EXISTING DOOR HEIGHT VERIFY IN FIELD � ���� ��� i
AlL CONSTRUCTION SHALL BE OF NON-COMBUSIIBLE MATERIALS �dJ6'�0� ��
EXCEPT WHERE PERMITTED BY CODE LEGEND DEMOLITION NOTES Re.ridence
/
CODE NOTES •e,`r� �� r—� EXISTING WAl1S TO RENIAIN � REMOVE EXISTING KITCHEN CABINETS AND APPl1ANCES
REPIACE WITH NEW KtTCNEN CABINEfS AND APPIJANCES
OCCUPANCY TYPE-R-1 ' S� 1""""'�"""�"�""� NEW PARTfTION AS SELECTED BY OWNER Vail, Colorado
CONSTRUCTION TYPE-TYPE 2,FIRE RATED ./
EXTERIOR WALIS-d HOUR � � ��� � C = _ � � EXISTING CONSTRUCTION TO BE REMOVED OB REMOVE EXISTING WALL AS SHOWN
S7RUCTURAL FRAME -2 HOUR �� _
FLOORS AND FLOOR-CEILINGS-2 HOUR � REMOVE EXISIING WALL AS SHOWN '
PERMAN�NT PART1T10NS- 1 HOUR CONSTRUCT NEW WALL AS SHOWN TO U� ��
NEW DOOR I N C R E A S E U N E N C I O S E t D E P T H
- �D REMOYE EXISTING WALLS AND DOOR AS SHOWN ����������
CONSTRUCT NEW WALL AND DOOR AS SHOWN
EXISTING DOOR TO REMAIN P I�1 1
Unit Floor Plan - Buildin Second Floor- _ _ _
revp n tio
SCAI.E: 1/4"= 1'-0" 03-0�0
n�:
Oaober9,2003 ��; � �
I I I nx�vx rr 0
� ral
sC�ir AS NOTED sHr r-�or � .
i�2003 Ci63�Architeds,mc