Loading...
HomeMy WebLinkAboutB10-0429 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES .� �ow�oFV�,� Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD/ALT MF BUILD PERMIT Permit #: B10-0429 Project #: PRJ10-0796 Job Address: 2109 N FRONTAGE RD W VAIL Status. . : ISSUED Location......: CITY MARKET EMPLOYEE HOUSING WING Applied . . : 12/08/2010 Parcel No....: 210311424025 Issued. .. : 12/14/2010 Expires. ..: 06/12/2011 OWNER TOWN OF VAIL 12/OS/2010 C/O DILLON REAL ESTATE CO PO BOX 5567 ATTN REAL ESTATE DEPT DENVER CO 80217 APPLICANT KTK GENERAL CONTRATING LIMIT 12l08/2010 Phone: 303-355-0013 3883 MONACO PKWY DENVER CO 80207 License: 1091-B CONTRACTOR KTK GENERAL CONTRATING LIMIT 12/08/2010 Phone:303-355-0013 3883 MONACO PKWY DENVER CO 80207 License: 1091-B Description: REPLACE APPROXIMATELY 60 SQ FEET OF DRYWALL IN HALLWAY CEILING. Occupancy: Valuation: $3,000.00 Type Construction: Total Sq Ft Added: 0 ,,....,,,,,..............................,,......,,......,,�.........,,,.,,........�... FEE SUMMARY ........,..«.�....����.x..................,,.....,,,...........,,,,.._._........«, Building Permit Fee------> $83.25 Will Cal Fee---------------------> $4.00 Total Calculated Fees-------------> $141.36 Plan Check--------------------> $54.11 Use Tax Fee---------------------> $0.00 Additional Fees-----------------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES-------------> $141.36 Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00 Payments------------------------------> $141.36 Total Calculated Fees--------> $141.36 BALANCE DUE-----------------------> $0.00 *f Flh1r*f*#'R4*�1r4***RYr1r*iFtrf*iY#Yrhkh*frf f RY�f%rtYrf f RhYYrY'Y'f rttr�A'tri1'i1'f f f Yef f f ff f rtYrYelRf iFf4f f fYeYe�kYrrt�A'rt�A'LYIi(#�Rf!*i�frir**1`***1`t�fefiR41�*f i`1r4f******R}f�Rf�k1'*fe4f*fi***d**at f�f*1rf1�l1`i�4f1`4k#ff1`41�1`1(!*f*1`1el�R***1`irir** DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the informatior as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM-4:00 PM. , ��1 ��l !o , �.�%.,�C� � n Signature of ner or Contract Date ���2��v�a) ��vr��NGS Print Name b Id_a It_co n stru ct i o n_pe rm it_041908 •�#�e�wwfw�fifixff*wwwwwww�f�#ffwwwwwww��#fff#+�www�wf#�ff�>ekwwwwRMkkk��Rf4x4wfwwww#fR*�f�1fkl�etww/w1kf�R*Rl4ftwRwlRRf##��R!!*ff}*wwwwwwfw�ffff��ff�>*�fffwwwwwfwMlf��ffxxffix*wwwwfff APPROVALS Permit#: 610-0429 as of 12-14-2010 Status: ISSUED .................................................................x,,,........�.,...,�.,....,,�.,,,.,,...........��..,x....,,,..........,.;.,.x......�,.�,,....,.....�..............., Item: 05100 BUILDING DEPARTMENT 12/09/2010 DRHOADES Action: AP OK TO APPROVE PER MARTIN H. NOTE ADDED TO PLANS TO CHECK ELECTRICAL FOR WATER DAMAGE. Item: 05600 FIRE DEPARTMENT ,,.>.......,.�...................................................................................................................�......,,�.,x.....,............,.......,,,.,...,...,.. See the Conditions section of this Document for any that may apply. b I d_a It_co n st ru cti o n_pe rm it_041908 t##ww�eA##��ifwwwww��f/��*44w+/w�w���fffeewfffw�4l�f�f��k+wwwwww�A�1�*�w*fw�wfiw�w�R�k��f#�fiff+*wwwwwf����!l���wwwwwwwwwwf��A#�1ff�x*wwwwf�wfffwf���fxffffMtw+f�wwrt4wwfw���f��x#���iw CONDITIONS OF APPROVAL Permit#: B10-0429 as of 12-14-2010 Status: ISSUED ................�,,...,..,..,��,.......,..............,.,....,..�..,.....�....,.�.,.x,,,.....,,.,........................,�...,.,.,...,.,,...........,....,,.,..,,.,,.�...,..,,,.....,, Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. bld_a It_co nstructio n_perm it_041908 B10-0429: Entries for Item:90 - BLDG-Final 09:31 11/29/2013 Action Comments By Date Unique_ Ke AP Martin 12/16/2010 A000140 025 Total Rows: 1 Page 1 *************+**********************+***********+******************************************* TOWN OF VAIL, COLORADO Statement *********************+*********************�+*+*******+************************************* Statement Number: R100002006 Amount: $141.36 12/14/201009:37 AM Payment Method: Cash Init: LC Notation: CASH FROM BRANDI JENNINGS, KTK GENERAL CONTRACTING ----------------------------------------------------------------------------- Permit No: B10-0429 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2103-114-2402-5 Site Address: 2109 N FRONTAGE RD W VAIL Location: CITY MARKET EMPLOYEE HOUSING WING Total Fees: $141.36 This Payment: $141.36 Total ALL Pmts: $141.36 Balance: $0.00 ******************************s**********************************************************+** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 83.25 PF 00100003112300 PLAN CHECK FEES 54.11 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- David Rhoades J��Q- p ya 9 � From: Mike McGee 'I Sent: Tuesday, December 07, 2010 2:50 PM ', To: Martin Haeberle; David Rhoades �i Cc: 'koppenhaferm@comcast.net';Inspectors I Subject: RE: CM442 I With this letter, I am OK doing an over-the-counter permit for repair provided they are only replacing what was already there and making repairs to damaged elements. I understand timing is critical for them. Michael McGee Deputy C11ief Vail Fire& Emergency Services Direct 970 479-2135 Mobile 970 376-0738 mmc�ee�vail o�V.COTTI _ From: koppenhaferm@comcast.net [mailto:koppenhaferm@comcast.net] Sent: Tuesday, December 07, 2010 10:36 AM To: David Rhoades; Mike McGee Subject: Fw: CM442 Matt Koppenhafer Owner/Vice President KTK General Contracting Limited 3883 Monaco Parkway Denver CO. 80207 Office 303-355-0013 Ce11303-994-0616 Fax 303-355-0776 koppenhaferm(c�r�,comcast.net From: "JO at American Abatement" <jo@americanabatement.com> Date: Tue, 7 Dec 2010 09:03:35 -0700 To: <Koppenhaferm@comcast.net> Subject: FW: CM442 From: familyenviro@aol.com [mailto:familyenviro@aol.com] Sent: Monday, December 06, 2010 2:02 PM To: jo@americanabatement.com Subject: CM442 1 `�:. ..�: �� �t � � � �� 4 �.� �� Department of Comm�ni#y Developmen��•= � ��` �` ��� `� x� ��� 75 South Frontage Road 4�'n .�.�� 4�y � � �_ ..�q �, � , � -i� Y '5. 4 � � ,.�.���A , � ,<: � �`��� �..t* � ��P� _ i«�_ . ,�r�- . ' V a�', Calorado�.8�-657F�y y}$ ++ -... ' -� 4 ' � � � �-., � - �. 3 ����� ;� � �, ��ti; �., � r:�Te1 � 97D-479 21°�8$a � ���,�t,'�, , � �,�� � �,.�� %� ��� . �` �%-t ���� �� �,��`: �. �, � �#� ��� 5 . ; � � Faic'��97a-d��� 2�5� �"�� � � �' �' �����=° ���� .. ' Web. �vwirv vailgov co ��� r .� . � ���� . . �'° r.��'�_� , ' �,����. �� . �' r _ �, : - Deve'Iop�� ent Revievv�oflic��n�t�� j . � °����'� ��`'��� ' _ Y� ' ._ ".' y '� z .��.. � .e Y � � �� .i:T �iFcshao�_�..__....._�_.,v�................._... � w3 * . � �,e � . ,..,.,.,.. �.i<�°.,2� BUILDING PERMIT APPLICATION Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. ;Project Street Address: �- v Office Use: ' l0( � � l U� �.��CI��C C,� �t� ����� . Project#: PR���" ���� ;(Number) (Street) (Suite#) DRB#: '���1� �Building/Complex Name� � � g �31D_Q 5/�C� r— � Buildin Permit#: �..�.,.�.��,m,.�.,,� � ..,�.,,,,�.,,�.�,,�,,�,,,,�._.�.,.�.n.�...,. ...�_. .a-.•,� Lot#: Block# Subdivision: .. �Contractor Information: - r � Company:��IL ����.,-��Ci, 1 Gi.�L�G� (��- ��Com an Address:��� 1`�\C`l1 1 r� �"? I P Y i � Detailed Des�ription of Work: 1�t'-�� l C�-( ; � � �L?Z C��i � / �' i €City:l J� (,L�?`���� State: C Zip: l l,� �.�!�i(� � � � i ; L �Contact Name: ��-� ���7f�'L� ��C1�� l-Jl� V �(,�!�� l � � ���������-l., _ ; �, � � -. !Contact Phone: ��)��j- � ���' � ��'( �G� � � � ti ( � y � �o W T 2 � + I.ECT21 CA� � F} E i f �� -y- / � ' (use additional shee necessary) �Mq�E E-Mail 1"�C�� � � �� f ��C. � �• L �.c�- ' ; � 1 � ' , �,.�w�...u. ..q�,��,.� �..���� �v n e. .....r,. �K,r.���.,AU�ssn _......�. � C J �Work Class: ;Town of ail ontr tor Registration No.: � �New( ) Addition ( ) Remodel (�Repair( ) Other( ) ' �� �� � ,.�...� �......��.�. ��: X C� ��. �Work Type�_...... 3 ;Contrac r Signature(required) � Interior(� Exterior( ) Both ( ) � �.,_.,..,.,. �,,.,.�.�.� _,���.�_... �.��K.�..�.�.��_.,.._.�...,�.,�..�,_.......,., ..� _..�., .....�A��....�.,,,�.�, �.au,u.w�.... .�_,�..��..�,,w...n,..�...,.�.»� e.w,�.��,� .._� ;Pro� rty Information d Type of Building: ' � � i ;Parcel#: ��D 3-�]y- ay oa- �J' � Single-Family-�Duplex( ) Mutti-Family( ) ; �(For parcel#,contact Eagle County Assessors Office at 970-328-8640 or 9 Commercial Other ;visit vwvw.eaglecounty.us/patie) � ) � ) < r�,�,,w>..,�,,�. ,....,.,�, ,,,��»�..�.,�..�� .,,,,-,�,�,..,.�.��.,, .,,�...: . 3 t .� E Tenant Name: ��G�L( ��Cti.��� � �Does a Fire Alarm Exist? Yes(� No O i � ,/ � j � �Monitored Alarm? Yes{�) No( ) j j Owner Name:� (')°��;'C. ����C-'t�f c.L-- � � Does a Sprinkler System Exist? Yes (� No O ; , .� ,,.� ��.�„ �,� , ...� �....,.�..�m�.�..�. ..s_.�_�.,e�.,..�...�,.� ._ �.��... �.,��,.._�.� �#&Type of Existing Fireplaces: Gas Appliances ���� � Valuations(Labor&Material)) ; E �, Gas Log Wood/Pellet Wood Buming � F Building: $ C ��� ; 3 =#&Type of Proposed Fireplaces: Gas Appliances ' ; Plumbing: $ ; Gas Log Wood/Pellet Wood Buming � � fl � __ _._ _ _. _.... __.._...__ ......i ; ��� �Electrical: $ (� Date Received: L� � L� � �l � �Mechanical: $ �} '' v E Total: $ ���� j �EC � � 2��� � __ __ __ _ _.. _ __� _,3�_ �� I TOWN OF VAIL c:\cdev\forms\permiLS\bu ilding\comm_buildmg�ermrt_1001 9 O1-Oct-09 � ��FjR\J � � � L '� j ��, '�� r.`` � f �, i �� \� eMFR�CY�.G�y� ��_, �-� Vail Fire Department Asbestos Testing &Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regu- lations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testinq required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two-Family Dwellings: 30 square feet All Others: 160 square feet Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified and Vail-registered abate- ment contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the Town of Vail before the building permit will be issued Project Checklist My project falls into the category checked below: �G�� � Will not disturb more than the threshold limits identified above. 1�y� � Tested negative, or at 1% or below (2 copies of test results included) � Tested positive at more than 1%, requires abatement (2 copies of test results included) Tips&Facts: • Even recent construction projects may include asbestos-containing materials, so buildings of a�age require testing. • The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take efFect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO3 81657. Town of Vail Contact: State of Colorado Contact: David Rhoades, Fire Inspector Colorado Department of Public Health Vail Fire Department and Environment 75 S Frontage Rd Asbestos Compliance Assistance Group drhoades@vailgov.com 303-692-3158 970-477-3454 asbestos@state.co.us www.vailqov.com www.cdphe.state.co.us c:\cdev\forms\permits\building\comm_bu ilding�ermit_100109 Asbestos Inspection Report CITY MARKET 2101 NORTH FRONTAGE ROAD WEST APARTMENTS A-F VAIL, CO 81657 � , w .. e .; aas - � - .... . . �,r�,�8 �„��h Y�:i eF r �#'� � ���# �y1,� t � �l4'�e:��a� I Y Y' �^'� k�,d F :�`°,�'"'��t MS, �,+,�y�, i.a,�G},.,.�C .Y� 5 1u�pr . 2�k rt�� � d<'�' ��,� ���r '�w � x �.��; � �` �, �' �� a:. t*. �� �'�'� �s��..r� �1^!�P�� d��'�'��n+���5 � ,ti '�'�� , � ����xt�����''���t�'y��.��rE.r '��'� X .��� e �� "�� ,• ���i r� �d ,t' . �" �°y,� �`aq"�r�`'�Nk. a�`��r �E �� �� ��,���`� ! # +„'`'� "'` .RgW f# � ���� � �`�� �AM�'�" �.i+u" I , � � .' ' :�,� , �. ��t , q, .,. k� ' € ,...,.. , �. 'M1�. s�h,r,: �., E � ,. , I � ` . ,. : . �: � . � . ....+ : '� .. '... '�' .d�, ,{ .... : . j��",.�. � ,.w',nx� ' i i.A'�. h�'. y�, �"� � r�� ` �� , � ,� t: k� ��.�� ��,� Y'V3' � � ~ ary � k ��� � Y s g ,�� ��� �`k{t�Y °�� ^�++ ;�»w.. ,_.� ���' �: � , .. �� � �� ^�-r �• � ��� ,.� � *�a:� ``�s�;�+���� ��.�. � �Q. � n�„;. ,;� .„W. � , �,,..,. ,.,; p�,,�it a 2... . . � �qx� � �r ;: �,� � *���,;t �' . � r .... Prepared For: King Soopers P.O. Box 5567 T.A. Denver, Colorado 80217 June 14th, 2010 Prepared By: Davld Cohn 1 i � " � Family Environmental Compliance Services, Inc. 3650 Chestnut Place Denver, Colorado 80216 Family Environmental City Market Store#442 3650 Chestnut Place 2101 North Frontage Road West,Apartments A-F Denver,CO 80216 Vail,CO 81657 CONTENTS Pa�e SECTION1 INTRODUCTION..........................................................................................5 SECTION 2 ASBESTOS INSPECTION............................................................................6 2.1 ASBESTOS CONTAINING MATERIALS.......................................................................6 2.2 SUSPECT ASBESTOS CONTAINING MATERIALS.....................................................7 23 ASBESTOS CONTAINING MATERIALS.......................................................................7 2.4 RECOMMENDATIONS....................................................................................................7 2.5 GENERAL COMMENTS..................................................................................................8 SECTION3 CONCLUSION ............................................................................................ 10 SECTION4 DISCLAIMER................................................................................................8 APPENDICES A FAMILY ENVIRONMENTAL COMPLIANCE SERVICES, INC. CERTIFICATIONS C ASBESTOS PLAM ANALYTICAL RESULTS Family Environmental City Market Store#442 3650 Chestnut Place 2101 North Frontage Road West,Apartments A-F Denver,CO 80216 Vail,CO 81657 SECTION 1 INTRODUCTION Family Environmental Compliance Services, Inc. (Family Environmental) was contracted by King Soopers, P.O. Box 5567 Denver, Colorado to perform an asbestos inspection, of the employee residential units at the City Market Store #442 located at 2109 North Frontage Road West Vail, CO 81657. The physical inspection was for the 2101 North Frontage Road West apartment units A-F Vail, CO 81657. The inspection was carried out on June 11, 2010. The apartments are built above the City Market at 2109 North Frontage Road West Vail, CO 81657. The apartments were built in 1997 using wood frame construction. Six apartment units were inspected, two 2 bedroom apartments and four 1 bedroom apartments. The purpose of this asbestos inspection was to document the specific building materials that may contain asbestos prior to any repairs or renovations. SECTION 2 ASBESTOS INSPECTION This asbestos inspection was conducted according to the United States Environmental Protection Agency (EPA)procedures published in 40 Code of Federal Regulations (CFR) Part 763, Subpart E—Asbestos-containing Materials in Schools. These inspection protocols specify requirements for the inspector(Section 763.85), laboratory(Section 763.87), and number of samples collected during an inspection (Section 763.86). Appendix A contains a copy of the certification of the inspector that surveyed store #13. This inspection involved identification and sampling of all affected suspect asbestos containing material (ACM) in all accessible areas located throughout the apartments. The City Market Store #442 was not involved during this inspection. The scope of this asbestos inspection was limited to materials that would be disturbed during mold remediation. Suspected materials include everything besides wood, ceramic, carpet, glass, metal and vinyl. Sampling procedures were performed in accordance with AHERA protocols. Random samples of suspect materials were collected in each homogeneous area. An appropriately attired inspector collected all bulk samples using wet methods, as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker. 2.1 ASBESTOS CONTAINING MATERIALS ACM is defined as any material containing greater than 1% asbestos. All sample testing is required to be performed by an accredited laboratory. ACM is categorized as either non-friable or friable asbestos. Non-friable asbestos is any material that cannot be crumbled, pulverized or reduced to a powder by hand pressure when dry. Friable asbestos can be crumbled, pulverized, or reduced to a powder by hand pressure when dry. The EPA and the Occupational Safety and Health Administration (OSHA) maintain a comprehensive list of suspect ACM frequently found during inspections. Family Environmental identified several of these suspect materials in the building. Appendix B contains a table that lists the type of materials sampled as well as the laboratory results. 2.2 SUSPECT ASBESTOS CONTAINING MATERIALS Certain building materials are commonly known to have asbestos levels greater than 1% so are therefore considered suspect ACM. The following suspect friable materials were observed during the inspection: • Surface Material/Drywall The following suspect non-friable materials were observed during the inspection: • Tape Joint Compound • Carpet Adhesive • Cove-Base/Glue • Insulation 2.3 ASBESTOS CONTAINING MATERIALS No asbestos containing materials were identified from the samples taken at Apartments A-F 2101 North Frontage Road West Vail, CO 81657. Many of the materials sampled and identified as suspect ACM were homogenous throughout the apartments. A homogeneous area is defined as any area in which materials appear to be similar throughout in terms of colar, texture, and date of application. Samples were collected from each homogenous area. I 2.4 RECOMMENDATIONS Bulk samples were submitted under chain of custody procedures to River North Environmental Testing (RNET) of Denver, Colorado, for analysis by polarized light microscopy(PLM) with dispersion staining techniques per EPA methodology(40 CFR 763, Subpart F). PLM visual estimation was used in obtaining the percentage of asbestos in bulk samples. RNET is accredited under the National Voluntary Laboratory Accreditation Program NVLAP (200448-0). Appendix C contains these analytical results. There are no U.S. EPA or OSHA regulations mandating the removal of asbestos containing material (ACM) from occupied commercial or residential buildings unless the ACM becomes impacted by renovation or demolition activities. A certified abatement contractor must abate asbestos containing building materials (ACBM) before any renovation or demolition activities affecting and/or disturbing this material can take place. Family Environmental did not identify any asbestos containing building materials within the store. Since no ACM was detected in the samples taken, no further action is required regarding the disturbance of building materials during repair or remodeling. Family Environmental recommends that you please work safely and if you encounter any other suspect building materials not listed in this report, then please contact Family Environmental for additional sampling. * This was not a complete inspection of the building. If any further renovation to the interior/exterior or complete demolition should occur, the materials to be affected by the work should be inspected by a Colorado State certified building inspector. 2.5 GENERAL COMMENTS This asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, expressed in this report are based on conditions observed during our inspection of the building. The information contained in this report is relevant to the date on which this inspection was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by King Soopers. Contractors or consultants reviewing this report must draw their own conclusions regarding the existence or potential existence of ACM in the store. Family Environmental does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, expressed or implied is made. SECTION 3 CONCLUSION Family Environmental has performed this asbestos inspection for the properties located at 2101 North Frontage Road West Apartments A-F Vail, CO 81657. Testing confirmed the absence of ACM at locations sampled. Since all samples taken tested negative for ACM there is no further action required regarding repair or renovation activities. � SECTION 4 DISCLAIMER Reasonable effort was made by Family Environmental Compliance Services, Inc. to locate and sample suspect materials. However, for any facility, the existence of unique or concealed asbestos-containing materials and debris is a possibility. Family Environmental does not warrant, guarantee, or profess to have the ability to locate or identify all asbestos containing materials in the store. If you should have any questions or require additional information, please feel free to contact Samuel Rolf at (303) 296-6022. Thank you for choosing Family Environmental Compliance Services, Inc. We are happy to be of service to you. Appendix A Family Environmental Asbestos Inspector Certification Appendix B RNET Results for Apartments A-F City Market #442 2101 North Frontage Road West Vail, CO 81657 Sample Number Material/Description Location(s) Friable Sample Analysis INS1-1 White Blown-in Apt. 2101-C Attic Above Bedroom No ND Insulation INS1-2 White Blown-in Apt. 2101-A Attic Above Hallway No ND Insulation INS1-3 White Blown-in Apt. 2101-F Attic Above Bathroom No ND Insulation SMW1-1 White Surface Apt. 2101-C Bedroom Closet East Yes ND Material/Drywall Wall SMW1-2 White Surface Apt. 2101-A Hall Closet South East Yes ND Material/Drywall Wail SMW1-3 White Surface Apt. 2101-B Under Window North Yes ND Material/Drywall East Wall SMW1-4 White Surface Apt. 2101-D Bedroom South East Yes ND Material/Drywall Wall Behind Door SMW1-5 White Surface Apt. 2101-F East Bedroom Behind Yes ND Material/Drywall Door SMW1-6 White Surface Apt. 2101-F Bedroom Closet North Yes ND Material/Drywall Wall SMW1-7 White SurFace Apt. 2101-E Bathroom South Wall Yes ND Material/Drywall TJC1-1 White Tape Joint Apt. 2101-C Entry Closet North Wall No ND Compound White Tape Joint Apt. 2101-A Bedroom Closet North TJC1-2 Compound West Wall No ND White Tape Joint Apt. 2101-B Bedroom Closet North TJC1-3 Compound Wall No ND TJC1-4 White Tape Joint Apt. 2101-D Bathroom South East No ND Compound Wall TJC1-5 White Tape Joint Apt. 2101-F Bedroom Closet West No ND Compound Wall TJC1-6 White Tape Joint Apt. 2101-F Entry Hall South Wall No ND Compound TJC1-7 White Tape Joint Apt. 2101-E Bathroom South Wall No ND Compound Sample Number Material/Description Location(s) Friable Sample Analysis CB1-1 Tan Cove Base And Apt. 2101-C Bedroom Closet East No ND Adhesive 4" Wall C61-2 Tan Cove Base And Apt. 2101-A South East Wall Behind No ND Adhesive 4" Front Door C61-3 Tan Cove Base And Apt. 2101-B Bedroom Closet East No ND Adhesive 4" Wail CB1-4 Tan Cove Base And Apt. 2101-D Entry Hall North West No ND Adhesive 4" Wall CB1-5 Grey Cove Base And Apt. 2101-F Bathroom East Wall No ND Adhesive 4" CB1-6 Brown Cove Base And Apt. 2101-E Bedroom Closet West No ND Adhesive 4" Wall GL1-1 Yellow Carpet Glue Apt. 2101-C In Bedroom Closet No ND GL1-2 Yellow Carpet Glue Apt. 2101-A In Bedroom Closet No ND GL1-3 Yellow Carpet Glue Apt. 2101-F In Bedroom Closet No ND ND=Non-Detect