Loading...
HomeMy WebLinkAboutA10-0112TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A10 -0112 Job Address: 1245 WESTHAVEN CR VAIL Status ...: ISSUED Location.....: A SIDE Applied..: 12/09/2010 Parcel No...: 210312107016 Issued . .: 12/13/2010 Project No Expires. .: 06/11/2011 OWNER MCMAHON TRUST 12/09/2010 792 SAN LORENZO ST SANTA MONICA CA 90402 APPLICANT THUL ELECTRONIC SYSTEMS 12/09/2010 Phone: 970 - 949 -4638 P O BOX 534 AVON CO 81620 License: 112 -S CONTRACTOR THUL ELECTRONIC SYSTEMS 12/09/2010 Phone: 970 - 949 -4638 P O BOX 534 AVON CO 81620 License: 112 -S Desciption: NEW FIRE ALARM SYSTEM FOR UNIT A OF DUPLEX. NO OTHER WORK IS BEING DONE. FIRE ALARM PERMIT ONLY. Valuation: $2,200.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY *****►******************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Electrical --------- > $0.00 Total Calculated Fees - -> $370.50 DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00 Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $370.50 Will Call --------- > $0.00 Payments ------------------ > $370.50 TOTAL FEES - -> $370.50 BALANCE DUE--- - - - - -> $0.00 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Approvals: Item: 05600 FIRE DEPARTMENT 12/10/2010 mvaughan Action: AP CONDITIONS OF APPROVAL ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS I N ADVA>WA TELVHONE.I` 970 - 479 -2252 FROM 8:00 AM - 5 PM. ATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001995 Amount: $370.50 12/13/201011:23 AM Payment Method: Check Init: SAB Notation: 17446 THUL ELECTRONICS ----------------------------------------------------------------------------- Permit No: A10 -0112 Type: ALARM PERMIT Parcel No: 2103 -121- 0701 -6 Site Address: 1245 WESTHAVEN CR VAIL Location: A SIDE Total Fees: $370.50 This Payment: $370.50 Total ALL Pmts: $370.50 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 FIRE ALARM PERMIT FEES 82.50 PF 00100003112300 PLAN CHECK FEES 288.00 T Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 -2128 �'. ' A ` Fax: 970- 479 -2452 . ,- Web: www.vailgov.com Development jF FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: 1245 WESTHAVEN CIRCLE (Number) (Street) Building /Complex Name: Contractor Information: Company: Thul Electronics Company Address: PO Box 534 City: Avon State: CO Contact Name: Ron Davidson Detailed Description of Work: NEW FIRE ALARM Zip: 81620 SYSTEM FOR UNIT A OF DUPLEX. NO OTHER WORK IS BEING DONE. FIRE ALARM PERMIT Contact Phone: (970) 949 -4638 E -Mail ron @thulelectronics.com (use additional sheet if necessary) Town of Vail Contractor Registration No.: 112 - Does a Fire Alarm Exist? Yes ( ) No (� ) Dgiullys911d by Deborah Shane. Does a No Sprinkler System Exist? Yes X Deborah Shane. ou= FPE, ma =sh nerls Mom s[ neilerV9" P Y ) ( ) Dau: 3010.13 08 16,43:18 -07'W' Work Class: Contractor Signature (required) New ( ) Addition ( )Remodel ( )Repair ( ) Property Information Retro -Fit Other ( ) Parcel #: 2103- 121 -07 -016 (For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or Type of Building: visit www.eaglecounty.us /patie) Single - Family ( ) Duplex Multi - Family ( ) Tenant Name: Commercial ( ) Restaurant ( ) Other ( ) Owner Name: 1245 WESTHAVEN LLC Date Received: Complete Valuation for Fire Alarm Permit: D [� � h U Fire Alarm $: $22 00 DEC 0 8 2010 TOWN OF VA A (Suite #) Office Use: Project #: PF rT I i) C) 7 g j Building Permit #: 4/� - Alarm Permit #: tq 1 d ° Lot #: Block # Subdivision: ONLY. 29- May -09 Honeywell 5808W3 PHOTOELECTRIC SMOKE /HEAT DETECTOR WITH BUILT -IN WIRELESS TRANSMITTER Honeywell's 5808W3 is a 3V lithium powered, Since there are no holes to drill or wires to run, you can photoelectronic smoke /heat detector with a built -in preserve the beauty of the building while protecting it. The wireless transmitter. It is intended for use with any 5808W3 is an ideal smoke detector for those difficult to wire 5800 Series Wireless Receiver/Transceiver for residential locations, applications where room aesthetics are critical, or installations (for commercial installations, the 5881 ENHC where hazardous materials exist. or the 5883H receiver is required). The transmitter can send alarm, tamper, maintenance (when control panels are equipped to process maintenance signals), and battery condition messages to the system's receiver. Smoothing algorithms minimize nuisance alarms by smoothing out short term spikes from dust and smoke — virtually eliminating nuisance alarms. All models also feature a restorable, built -in, fixed temperature (135 °F) thermal detector that is also capable of sensing a pre - freeze condition if the temperature is below 41 °F. FEATURES • Improved Robust RF Field Strength The distance between the detector and receiver has been significantly increased without the need for a repeater • Drift Compensation Virtually eliminates nuisance alarms from long -term dust build -up by automatically adjusting the detector's sensitivity • Easy -to- install Mounting Base The sturdy mounting base allows the detector to be more easily installed on uneven surfaces (i.e. stucco). The mounting base has larger mounting ports, which accommodate drywall anchors for easy surface mounting. • Smoothing Algorithms Mathematical calculations in the detector's software that minimize nuisance alarms by smoothing out short term spikes from dust and smoke • Smart Check A signal is sent to the control panel when the detector requires cleaning. This allows a regular, non - emergency service call to clean the detector before it goes into alarm. • Removable Detector Cover and Chamber Top The technician is able to quickly and easily clean the detector chamber without disassembling the detector head • Approved UL Listings for Residential and Commercial Applications Both residential and commercial installation requirements are met • Additional LED Status Indicators Identifying between alarm or trouble conditions is a snap with green and red LED status indicators. A green I ED denotes a normal condition while the red LED indicates abnormal conditions. ADDITIONAL FEATURES: • Utilizes one long -life 3V lithium battery • Microcontroller runs on a 4.0 MHz clock • Horn operates at 3.3 KHz with sound pressure level of 85 dBA at 10 feet • Built -in wireless transmitter, temporal code 3 sounder • Maintenance signal fully complies with the sensitivity test requirement specified in NFPA 72, 7 -2.2 and is approved by UL 5808W3 PHOTOELECTRIC SMOKE /HEAT DETECTOR WITH BUILT -IN WIRELESS TRANSMITTER SPECIFICATIONS • Dimensions - Diameter: 5.3" *, Height: 2.30" • Weight - 8.5 ounces (without batteries) • Operating Temperature - 32 -100° F (0 -37.8° C) • Humidity Range - 0% to 95% RH, non - condensing • Air Velocity - 1,000 ft. /min. max. • Operating Voltage - 2.5- 3.6VDC • Standby Current - 8.5 mA avg. • Alarm Current - 35 mA max. * With adapter bracket (4.9" without mounting base) tReplacement batteries include Duracell DL123A, Sanyo CR123A, Panasonic CR123A, or ADEMCO 466 ACCESSORIES (sold separately) • Power Source - One 3V CR123A lithium Batteryt • Audible Output - 85 dB min. at 10 ft. • Fixed Temperature Heat Sensor - 135° F Fixed • Agency Listings - U1268 - Commercial and Residential SENS -RDR Infrared Sensitivity Reader Reduce testing time with the handheld SENS -RDR infrared sensitivity reader. The reader simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS -RDR eliminates the need for magnets, voltmeters and ladders. RT Removal Tool Simplifies the attachment and removal of the detector head to the mounting base; it may be attached to a threaded extension pole or broom handle thereby eliminating the need for ladders. ORDERING 5808W3 Photoelectric Smoke /Heat Detector with Built -in Wireless Transmitter Accessories sold separately: SENS -RDR Hand -held Sensitivity Reader RT i3 Removal Tool used for easy installation and removal of head from base Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com V5808W3DS /D September 2008 0 2008 Honeywell International Inc. Honeywell Honeywell 5809 WIRELESS HEAT DETECTOR u . P M Honeywell's 5809 wireless fixed heat and rate -of -rise temperature sensor offers expanded fire detection and installation flexibility. It is ideal for hard to wire locations and applications that require more than smoke detection. With no wires to run, the 5809 is fast and easy to install. The 5809 combines both rate -of -rise and fixed temperature sensors. Fires typically cause a rapid rise in temperature in the FEATURES surrounding area. The 5809's rate -of -rise thermostat senses the rise in temperature and signals an alarm if the increase is 15° or more per minute. A built -in fixed temperature sensor will also signal an alarm if the environmental temperature rises above 135 °F. The 5809 is UL Listed (UL521) and CSFM approved for commercial and residential applications. • Contains a built -in transmitter which can send alarm, supervisory and battery condition messages to the system's receiver /control unit • Powered by a three -volt lithium battery. If the battery voltage gets too low, the 5809 sends a low battery signal to the control panel • Features a tamper switch, which causes a trouble signal to be sent to the control if the unit is removed from the mounting base • UL Listed for Commercial (when using 5881 EH Receiver) or Residential applications 5809 WIRELESS HEAT DETECTOR SPECIFICATIONS: • Power: - 3V lithium battery (Duracell DL123A, Panasonic CR123A, Sanyo CR123A, Varta CR123A) - Operating temperature: 40° to 140 °F (6° to 60oC) - Rate -of -rise temperature: 15 °F (8 °C) increase per minute (NOTE: Rate -of- rise sensor does not operate above 38 °C) - Fixed temperature; 135 °F (57 °C) - Maximum spacing; 50 ft x 50 ft UL, 30 ft x 30 ft FM (refer to National Fire Alarm Code Standard NFPA 72 for application requirements) - Dimensions: 4.4" diameter /2/2" deep a Agency Listings: - UL 521 Listed for Commercial (when using 5881 EH Receiver) or MOUNTING THE DETECTOR: Residential applications a Wireless Transmission Path Test: - A good RF transmission path must be established from the proposed mounting location before permanently installing the detector. To determine that there is a good signal reception from the proposed location, perform the test procedure described in the installation instructions procedure. - You can mount the 5809 on a wall or ceiling within the protection area: - Wall mounting: Mount the detector 4" 6" from the ceiling Ceiling mounting: Mount the detector at least 4" from any wall. Make sure the normal ceiling temperature will not exceed 100 °F (37.8° C). TESTING THE DETECTOR: - Refer to NFPA Standard 72 for detector spacing and other requirements. Maximum spacing for UL installations is 50' x 50' - Avoid mounting the detector near heat generating devices (e.g. ovens, heat vents, furnaces, boilers) IMPORTANT: Heat detectors should be used for property protection. Reliance should not be placed soley on heat detectors for life safety. When life safety is involved, smoke detectors MUST also be used. Detectors must not be painted. The test procedure should be performed to determine a good RF transmission path and again after installation is completed. CAUTION: The fixed temperature sensor is intended for one -time use. Prolonged heat during testing can damage the unit. If used carefully following the instructions described below, the heat from a portable hair dryer can be used to test the unit. If the round disk on top of the detector detaches, the detector must be replaced. - Activiate the control panel's test mode ORDERING 5809 Heat Detector - Use either method (a) or (b) or activate - Exit the control's test mode the detector FCC ID: CFS 8DL 5809 (a) Press and release the activation button on the PC board assembly OR (b) Holding a portable hair dryer about 12 to 18 inches away from the detector, turn the dryer on and aim the warm air at the side of the detector. CAUTION: Aiming the dryer directly at the round disk on the detector can damage the unit to be replaced. - The system's keypad should beep and the detector's ID should be displayed Honeywell Security & Custom Electronics Honeywell 2 Corporate Center Drive Suite 100 P.O. 9040 Melville, NY 11747 www.honeywell.com This device complies with part 15 of FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Honeywell U58WD October 2007 0 2007 Honeywell International Inc. 6160 ALPHA DISPLAY KEYPAD r I WITH DOOR ATTACHED WITHOUT DOOR The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white console blends with any decor and features a contoured, removable door that conceals illuminated soft -touch keys. The 6160 also features a new larger and brighter 32- character display with easy -to -read plain - English status messages. FEATURES The oversized function keys are easily accessed even when the keypad door is closed, and can be programmed for fire, burglary, personal emergencies and other operations. Colored self- adhesive labels are included. • Large, easy -to -use keypad • Keys continuously backlit for greater visibility • Speaker with audible beeps to indicate: System status Entry/exit delay Other alarm situations SPECIFICATIONS • Zones and system events displayed in plain English • No confusing blinking lights • Four programmable function keys • System functions clearly labeled • Functions performed by just entering security code plus command • White with removable door blends with any decor Physical • 5- 5/16 "H x 7 -3/8 "W x 1- 3/16 "D (135mm x 190mm x 30mm) Current • Standby -40mA • Activated Transmission- 1 60mA Wiring • - (Black): Ground • + (Red): +12 VDC (Aux. Power) • D1 (Green): "Data in" to control panel • DO (Yellow): "Data out' from control panel ORDERING 6160 Alpha Display Keypad Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com C006010 U6160/D September 2006 0 2006 Honeywelt International Inc. Compatibility • Fully compatible with all VISTA controls. Honeywell SYSTEM SENSOR" C01 224T Carbon Monoxide Detector with RealTest "Technology The System Sensor CO 1224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features RealTest technology allows installer to test detector with CO gas Full compliance with UL 2075 A code required trouble relay • Wiring supervision with SEMS terminals A six year end -of -life timer 12/24 VDC A current draw of 20mA in standby and 40mA in alarm • Versatile mounting for wall and ceiling • Electrochemical sensing technology With RealTest technology, the CO gas sensing cell of the COI 224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test button for two seconds. After the alarm cycle (temp 4) the green LED will flash about once per second, indicating that the detector is ready to accept CO for testing. Spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. If dangerous amounts of carbon monoxide is detected, the C01 224T detector will alert residents by sounding and flashing a temp -4 signal alarm. Protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. This specific device is designed for system operation. The detector is fully listed to UL 2075. It offers a code required trouble relay to send a sensor failure or end -of -life signal to the control panel and the central station. It also uses SEMS -type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision.The COI 224T detector offers a low current draw, allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The COI 224T model will operate on most industry security and fire Agency Listings alarm control panels because it is is a 12/24 VDC detector. U` LISTED C01 224T Carbon Monoxide Detector Specifications Carbon monoxide detector shall be a System Sensor model number COI 224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay. The detector's base shall be able to mount to a single -gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end -of -life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end -of -life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings Specifications 0.5 A @ 30 VDC i Physical Size Length: 5.1 in, Width: 3.3 in, Height: 1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104° F (0 °C to 40° C) Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single -gang back box, surface mount to wall or ceiling Modes Normal (standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern Rearrest" Feature: The System Sensor COI 224T carbon monoxide detector with Rearrest" can evaluate the functionality of the CO sensing cell using canned test agent. Push and hold theTest/Hush button for Spray canned CO agent into the detector. Verify CO sensing at the control panel. The two seconds to enter Rearrest mode. The detector will automatically exit Rearrest green LED will flash once every second to alarm mode after about 20-60 seconds. indicate RealTest mode has started. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing the Test /Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End -of -life Timer: After the detector's internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. Ordering Information C01224T 12/24 volt, 4 -wire system- monitored carbon monoxide detector with RealTest Technology S YSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Pd ozooasrn. d s An , SENSOR' n, rod —H a�ro�a�g� ��— Phone: 800 SENSOR2 •Fax: 630 377 6495 Re 1 n' °�° ^b^^r�° 3 7.OW - aM - n.5 dasa n..c A05-04 # 1953 Honeywell Piezo Dynamic Series (PD) SIRENS WAVE2PD Honeywell's Piezo Dynamic (PD) WAVE2PD and 747PD Sirens produce traditional "speaker" sound while drawing 1/4 the current of typical sirens. This allows multiple devices to be installed on the same alarm panel without the need for additional hardware, costs and labor. FEATURES CE 747PD The sirens feature a sleek, lightweight design, an easy -to -wire terminal block and a hinged case cover. The WAVE2PD and 747PD Sirens are globally compliant and UL approved and ideal for residential application. • Low current draw lets you add additional sirens in areas • Hinged case cover with elliptical mount holes provide like basements, garages, hallways and more installation convenience • Two tones to choose from: Steady and Warble • Tampered versions available to provide an added level of • Lightweight ABS plastic case is less than half the weight protection and meet global requirements of standard sirens • Compatible with LYNX control panels • Enclosed PCB to protect components • Large wiring channel provides plenty of room for wire • Easy -to -wire terminal block eliminates the need to splice and crimp wire Dimensions: See reverse side for dimensional drawings and ordering information Piezo Dynamic Series (PD) SIRENS SPECIFICATIONS WAVE2PD o.ss" -1ao• Sound Output 1.40 • 105dB @ 1 meter i �� � 0.15' Current Draw • 120mA ` 14�s 4.46' / 3.15" Operation Voltage+ • 12VDC'` a \j 325• Dimensional Drawing for WAVE2PD Siren 747PD 1.25• 015 Sound Output � N0 • 105dB @ 1 meter Current Draw 4.25" • 120mA Operation Voltage I \ • 12VDC flv 4.25" Dimensional Drawing for 747PD Siren ORDERING WAVE2PD Piezo Dynamic Siren WAVE2PDT Piezo Dynamic Siren with Tamper 747PD Piezo Dynamic Siren 747PDT Piezo Dynamic Siren with Tamper Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com PL06005 UPIEZODYN/D May 2006 02006 Honeywell International Inc. 3.25" Honeywell Honeywell VISTA -50P CONTROL PANEL l� L I- N�l F �- Honeywell's VISTA -50P Control Panel provides the flexibility of up to eight independent partitions with the economy of a single control. FEATURES Dependable features to meet your most demanding installations: • Nine hardwired zones standard • Expandable to 87 total zones • Eight partitions standard • 75 user codes work in all partitions • Seven authority levels • 224 event memory log /printer option • Four trigger outputs • 5800 Series wireless compatibility • Supports two -wire multiplex • Scheduling of events (real time clock) • Keypad macro features • Master console option for viewing all partitions at a glance • Common lobby logic • Fast downloading • Supports up to 16 relays and /or X -10 • Quick start programming • False alarm features • UL Commercial Burglary listed (VISTA- 50PUL) End users will appreciate the easy -to -use convenience and control features of the VISTA -50P: • Wireless remote controls (featuring single button system operation): — 5804 - Four -Button Wireless Key — 5804BD - Bidirectional Four -Button Wireless Key with system status feedback • Single or dual- button wireless personal panic: — 5802MN — 5802MN2 • Home control features activate lights, appliances, garage doors and numerous other devices • The VISTA Interactive Phone Module (VIP) gives the end -user control of their system from any touchtone phone. The 4286 VIP responds in English, with a vocabulary of over 100 words • Full English display keypads for clear understanding of system status and zone locations • Timed event applications: — Opens garage doors and turns on lights — Provides "lived -in look" while away from home — Ability to limit access to parts of the home at certain times VISTA -50P CONTROL PANEL SPECIFICATIONS Electrical • Aux power 12VDC, 750mA max • 16.5 VAC /40 VA transformer • Alarm output 12VDC, 1.7 Amps max • For UL installations, combined Aux and alarm output cannot exceed 750mA Output Control • Supports up to four relay boards (Part No. 4204) • Each board supports four relays for a total of 16 • Optional X -10 interface (Part No. 4300) may be used to control X -10 receiving devices • Each X -10 receiver address counts as one relay when computing total relays • Real time clock can be used for relay/X -10 control Zones • Nine hardwired zones • Selectable response on zone 9: 10MSec or 500MSec • Assignable to any partition • 14 zone types to choose from • Programmable swinger suppression Communications • Touchtone or pulse • Formats supported: ADEMCO Contact ID, ADEMCO 4 + 2 Express, ADEMCO low speed • 3 +1, 4 +1 and 4 +2 reporting • Reporting capabilities: Split, Dual, Split/Dual • Low battery reports 11.2- 11.6VDC • Expanded reporting • Up to four digit PABX codes supported • True dial tone detection • Double pole line seizure • AC loss and restoral reporting supported Supported Devices Hardwired Expansion Devices • 4208U Eight -Zone Expansion Module • Keypads — 6139 Custom English (required for programming) -100mA — 6128 Fixed English LCD - 30mA • Voice Module 4286 VIP -160mA • Two -Wire Smoke Detectors • Duct Detectors • Serial Printer • Polling Loop Devices • Key Switch Devices Wireless Receiver Systems • 5800 Series — 5881 ENL up to 8 zones -50mA — 5881 ENM up to 16 zones -50mA — 5881 ENH up to 26 zones -50mA • All Receivers Support: — Diversity reception with two antennea — Remote mounting for best location — Use of second receiver for maximum coverage or tough installations — Unique supervision and low battery indications by point Transmitters • 5800 Series — Three volt Duracell lithium batteries — One mile range — Tamper standard Agency Listings • UL Residential Fire and Burglary and CSFM • UL Commercial Burglary (VISTA- 50PUL) ORDERING VISTA -50P Control Panel Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com LNIS50P /D September 2008 0 2008 Honeywell International Inc. Honeywell