HomeMy WebLinkAboutA10-0112TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970 - 479 -2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT
Permit #:
A10 -0112
Job Address: 1245 WESTHAVEN CR VAIL
Status ...:
ISSUED
Location.....: A SIDE
Applied..:
12/09/2010
Parcel No...: 210312107016
Issued . .:
12/13/2010
Project No
Expires. .:
06/11/2011
OWNER MCMAHON TRUST 12/09/2010
792 SAN LORENZO ST
SANTA MONICA
CA 90402
APPLICANT THUL ELECTRONIC SYSTEMS 12/09/2010
Phone: 970 - 949
-4638
P O BOX 534
AVON
CO 81620
License: 112 -S
CONTRACTOR THUL ELECTRONIC SYSTEMS 12/09/2010
Phone: 970 - 949
-4638
P O BOX 534
AVON
CO 81620
License: 112 -S
Desciption: NEW FIRE ALARM SYSTEM FOR UNIT A OF DUPLEX. NO OTHER WORK
IS BEING DONE. FIRE ALARM PERMIT ONLY.
Valuation: $2,200.00
************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY *****►******************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Electrical --------- > $0.00 Total Calculated Fees - -> $370.50
DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00
Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $370.50
Will Call --------- > $0.00 Payments ------------------ > $370.50
TOTAL FEES - -> $370.50 BALANCE DUE--- - - - - -> $0.00
************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Approvals:
Item: 05600 FIRE DEPARTMENT
12/10/2010 mvaughan Action: AP
CONDITIONS OF APPROVAL
************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS I N ADVA>WA TELVHONE.I` 970 - 479 -2252 FROM 8:00 AM - 5 PM.
ATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
TOWN OF VAIL, COLORADO Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: R100001995 Amount: $370.50 12/13/201011:23 AM
Payment Method: Check Init: SAB
Notation: 17446 THUL
ELECTRONICS
-----------------------------------------------------------------------------
Permit No: A10 -0112 Type: ALARM PERMIT
Parcel No: 2103 -121- 0701 -6
Site Address: 1245 WESTHAVEN CR VAIL
Location: A SIDE
Total Fees: $370.50
This Payment: $370.50 Total ALL Pmts: $370.50
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
BP 00100003111100 FIRE ALARM PERMIT FEES 82.50
PF 00100003112300 PLAN CHECK FEES 288.00
T Department of Community Development
75 South Frontage Road
Vail, Colorado 81657
Tel: 970 - 479 -2128
�'.
' A ` Fax: 970- 479 -2452
.
,- Web: www.vailgov.com
Development
jF
FIRE ALARM PERMIT
Commercial and Residential Fire Alarm shop drawings are required at the time of application
submittal and must included information listed on the 2nd page of this form. Application will
not be accepted without this information.
Project Street Address:
1245 WESTHAVEN CIRCLE
(Number) (Street)
Building /Complex Name:
Contractor Information:
Company: Thul Electronics
Company Address: PO Box 534
City: Avon State: CO
Contact Name: Ron Davidson
Detailed Description of Work: NEW FIRE ALARM
Zip: 81620 SYSTEM FOR UNIT A OF DUPLEX. NO OTHER
WORK IS BEING DONE. FIRE ALARM PERMIT
Contact Phone: (970) 949 -4638
E -Mail ron @thulelectronics.com
(use additional sheet if necessary)
Town of Vail Contractor Registration No.:
112 - Does a Fire Alarm Exist? Yes ( ) No (� )
Dgiullys911d by Deborah Shane. Does a No
Sprinkler System Exist? Yes
X Deborah Shane. ou= FPE, ma =sh nerls Mom s[ neilerV9" P Y ) ( )
Dau: 3010.13 08 16,43:18 -07'W'
Work Class:
Contractor Signature (required)
New ( ) Addition ( )Remodel ( )Repair ( )
Property Information
Retro -Fit Other ( )
Parcel #: 2103- 121 -07 -016
(For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or Type of Building:
visit www.eaglecounty.us /patie) Single - Family ( ) Duplex Multi - Family ( )
Tenant Name: Commercial ( ) Restaurant ( ) Other ( )
Owner Name: 1245 WESTHAVEN LLC
Date Received:
Complete Valuation for Fire Alarm Permit: D [� � h U
Fire Alarm $: $22 00
DEC 0 8 2010
TOWN OF VA
A
(Suite #)
Office Use:
Project #: PF rT I i) C) 7 g j
Building Permit #: 4/� -
Alarm Permit #: tq 1 d °
Lot #: Block # Subdivision:
ONLY.
29- May -09
Honeywell
5808W3
PHOTOELECTRIC SMOKE /HEAT
DETECTOR WITH BUILT -IN
WIRELESS TRANSMITTER
Honeywell's 5808W3 is a 3V lithium powered,
Since there are no holes to drill or wires to run, you can
photoelectronic smoke /heat detector with a built -in
preserve the beauty of the building while protecting it. The
wireless transmitter. It is intended for use with any
5808W3 is an ideal smoke detector for those difficult to wire
5800 Series Wireless Receiver/Transceiver for residential
locations, applications where room aesthetics are critical, or
installations (for commercial installations, the 5881 ENHC
where hazardous materials exist.
or the 5883H receiver is required).
The transmitter can send alarm, tamper, maintenance (when
control panels are equipped to process maintenance signals),
and battery condition messages to the system's receiver.
Smoothing algorithms minimize nuisance alarms by
smoothing out short term spikes from dust and smoke —
virtually eliminating nuisance alarms.
All models also feature a restorable, built -in, fixed temperature
(135 °F) thermal detector that is also capable of sensing a
pre - freeze condition if the temperature is below 41 °F.
FEATURES
• Improved Robust RF Field
Strength
The distance between the detector
and receiver has been significantly
increased without the need for a
repeater
• Drift Compensation
Virtually eliminates nuisance alarms
from long -term dust build -up by
automatically adjusting the detector's
sensitivity
• Easy -to- install Mounting Base
The sturdy mounting base allows the
detector to be more easily installed
on uneven surfaces (i.e. stucco). The
mounting base has larger mounting
ports, which accommodate drywall
anchors for easy surface mounting.
• Smoothing Algorithms
Mathematical calculations in the
detector's software that minimize
nuisance alarms by smoothing out
short term spikes from dust and
smoke
• Smart Check
A signal is sent to the control panel
when the detector requires cleaning.
This allows a regular, non - emergency
service call to clean the detector
before it goes into alarm.
• Removable Detector Cover and
Chamber Top
The technician is able to quickly and
easily clean the detector chamber
without disassembling the detector
head
• Approved UL Listings for Residential
and Commercial Applications
Both residential and commercial
installation requirements are met
• Additional LED Status Indicators
Identifying between alarm or trouble
conditions is a snap with green and
red LED status indicators. A green I ED
denotes a normal condition while the
red LED indicates abnormal conditions.
ADDITIONAL FEATURES:
• Utilizes one long -life 3V lithium
battery
• Microcontroller runs on a 4.0 MHz
clock
• Horn operates at 3.3 KHz with sound
pressure level of 85 dBA at 10 feet
• Built -in wireless transmitter, temporal
code 3 sounder
• Maintenance signal fully complies
with the sensitivity test requirement
specified in NFPA 72, 7 -2.2 and is
approved by UL
5808W3
PHOTOELECTRIC SMOKE /HEAT DETECTOR WITH BUILT -IN WIRELESS TRANSMITTER
SPECIFICATIONS
• Dimensions
- Diameter: 5.3" *, Height: 2.30"
• Weight
- 8.5 ounces (without batteries)
• Operating Temperature
- 32 -100° F (0 -37.8° C)
• Humidity Range
- 0% to 95% RH, non - condensing
• Air Velocity
- 1,000 ft. /min. max.
• Operating Voltage
- 2.5- 3.6VDC
• Standby Current
- 8.5 mA avg.
• Alarm Current
- 35 mA max.
* With adapter bracket (4.9" without mounting base)
tReplacement batteries include Duracell DL123A, Sanyo CR123A, Panasonic CR123A, or ADEMCO 466
ACCESSORIES (sold separately)
• Power Source
- One 3V CR123A lithium Batteryt
• Audible Output
- 85 dB min. at 10 ft.
• Fixed Temperature Heat Sensor
- 135° F Fixed
• Agency Listings
- U1268 - Commercial and
Residential
SENS -RDR Infrared
Sensitivity Reader
Reduce testing time with the
handheld SENS -RDR infrared
sensitivity reader. The reader
simplifies sensitivity measurements
and displays them precisely in
terms of percent per foot
obscuration. The SENS -RDR
eliminates the need for magnets,
voltmeters and ladders.
RT Removal Tool
Simplifies the attachment
and removal of the
detector head to the
mounting base; it may
be attached to a threaded
extension pole or broom
handle thereby eliminating
the need for ladders.
ORDERING
5808W3 Photoelectric Smoke /Heat Detector with Built -in Wireless Transmitter
Accessories sold separately:
SENS -RDR Hand -held Sensitivity Reader
RT i3 Removal Tool used for easy installation and removal of head from base
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
www.honeywell.com
V5808W3DS /D
September 2008
0 2008 Honeywell International Inc.
Honeywell
Honeywell
5809
WIRELESS HEAT DETECTOR
u .
P M
Honeywell's 5809 wireless fixed heat and rate -of -rise
temperature sensor offers expanded fire detection and
installation flexibility. It is ideal for hard to wire locations and
applications that require more than smoke detection. With no
wires to run, the 5809 is fast and easy to install.
The 5809 combines both rate -of -rise and fixed temperature
sensors. Fires typically cause a rapid rise in temperature in the
FEATURES
surrounding area. The 5809's rate -of -rise thermostat senses
the rise in temperature and signals an alarm if the increase is
15° or more per minute. A built -in fixed temperature sensor
will also signal an alarm if the environmental temperature rises
above 135 °F. The 5809 is UL Listed (UL521) and CSFM
approved for commercial and residential applications.
• Contains a built -in transmitter which
can send alarm, supervisory and
battery condition messages to the
system's receiver /control unit
• Powered by a three -volt lithium
battery. If the battery voltage gets too
low, the 5809 sends a low battery
signal to the control panel
• Features a tamper switch, which
causes a trouble signal to be sent to
the control if the unit is removed from
the mounting base
• UL Listed for Commercial (when using
5881 EH Receiver) or Residential
applications
5809
WIRELESS HEAT DETECTOR
SPECIFICATIONS:
• Power:
- 3V lithium battery (Duracell DL123A,
Panasonic CR123A, Sanyo CR123A,
Varta CR123A)
- Operating temperature: 40° to
140 °F (6° to 60oC)
- Rate -of -rise temperature: 15 °F (8 °C)
increase per minute (NOTE: Rate -of-
rise sensor does not operate above
38 °C)
- Fixed temperature; 135 °F (57 °C)
- Maximum spacing; 50 ft x 50 ft UL,
30 ft x 30 ft FM (refer to National Fire
Alarm Code Standard NFPA 72 for
application requirements)
- Dimensions: 4.4" diameter /2/2"
deep
a Agency Listings:
- UL 521 Listed for Commercial
(when using 5881 EH Receiver) or
MOUNTING THE DETECTOR:
Residential applications
a Wireless Transmission Path Test:
- A good RF transmission path must
be established from the proposed
mounting location before permanently
installing the detector. To determine
that there is a good signal reception
from the proposed location, perform
the test procedure described in the
installation instructions procedure.
- You can mount the 5809 on a wall or
ceiling within the protection area:
- Wall mounting: Mount the detector
4" 6" from the ceiling
Ceiling mounting: Mount the detector
at least 4" from any wall. Make sure
the normal ceiling temperature will not
exceed 100 °F (37.8° C).
TESTING THE DETECTOR:
- Refer to NFPA Standard 72 for
detector spacing and other
requirements. Maximum spacing for
UL installations is 50' x 50'
- Avoid mounting the detector near
heat generating devices (e.g. ovens,
heat vents, furnaces, boilers)
IMPORTANT: Heat detectors should
be used for property protection.
Reliance should not be placed soley
on heat detectors for life safety.
When life safety is involved, smoke
detectors MUST also be used.
Detectors must not be painted.
The test procedure should be performed
to determine a good RF transmission
path and again after installation is
completed.
CAUTION: The fixed temperature sensor
is intended for one -time use. Prolonged
heat during testing can damage the unit.
If used carefully following the instructions
described below, the heat from a portable
hair dryer can be used to test the unit. If
the round disk on top of the detector
detaches, the detector must be replaced.
- Activiate the control panel's test mode
ORDERING
5809 Heat Detector
- Use either method (a) or (b) or activate - Exit the control's test mode
the detector FCC ID: CFS 8DL 5809
(a) Press and release the activation
button on the PC board assembly OR
(b) Holding a portable hair dryer about
12 to 18 inches away from the detector,
turn the dryer on and aim the warm air
at the side of the detector.
CAUTION: Aiming the dryer directly at
the round disk on the detector can
damage the unit to be replaced.
- The system's keypad should beep and
the detector's ID should be displayed
Honeywell Security & Custom Electronics
Honeywell
2 Corporate Center Drive Suite 100
P.O. 9040
Melville, NY 11747
www.honeywell.com
This device complies with part 15 of
FCC rules.
Operation is subject to the following
conditions:
(1) This device may not cause harmful
interference, and (2) this device must
accept any interference received,
including interference that may cause
undesired operation.
Honeywell
U58WD
October 2007
0 2007 Honeywell International Inc.
6160
ALPHA DISPLAY KEYPAD
r
I
WITH DOOR ATTACHED
WITHOUT DOOR
The 6160 Deluxe Keypad is easy to install and simple to
use. The attractive white console blends with any decor and
features a contoured, removable door that conceals
illuminated soft -touch keys. The 6160 also features a new
larger and brighter 32- character display with easy -to -read
plain - English status messages.
FEATURES
The oversized function keys are easily accessed even when
the keypad door is closed, and can be programmed for fire,
burglary, personal emergencies and other operations. Colored
self- adhesive labels are included.
• Large, easy -to -use keypad
• Keys continuously backlit for greater
visibility
• Speaker with audible beeps
to indicate:
System status
Entry/exit delay
Other alarm situations
SPECIFICATIONS
• Zones and system events displayed
in plain English
• No confusing blinking lights
• Four programmable function keys
• System functions clearly labeled
• Functions performed by just entering
security code plus command
• White with removable door blends
with any decor
Physical
• 5- 5/16 "H x 7 -3/8 "W x 1- 3/16 "D
(135mm x 190mm x 30mm)
Current
• Standby -40mA
• Activated Transmission- 1 60mA
Wiring
• - (Black): Ground
• + (Red): +12 VDC (Aux. Power)
• D1 (Green): "Data in" to control panel
• DO (Yellow): "Data out' from
control panel
ORDERING
6160 Alpha Display Keypad
Honeywell Security & Custom Electronics
Honeywell International Inc.
PO Box 9035
Syosset, NY 11791
www.honeywell.com
C006010
U6160/D
September 2006
0 2006 Honeywelt International Inc.
Compatibility
• Fully compatible with all
VISTA controls.
Honeywell
SYSTEM
SENSOR"
C01 224T
Carbon Monoxide
Detector
with RealTest "Technology
The System Sensor CO 1224T CO detector provides early
warning by using electrochemical sensing technology
to measure carbon monoxide levels in the air.
Features
RealTest technology allows installer to test detector with CO gas
Full compliance with UL 2075
A code required trouble relay
• Wiring supervision with SEMS terminals
A six year end -of -life timer
12/24 VDC
A current draw of 20mA in standby and 40mA in alarm
• Versatile mounting for wall and ceiling
• Electrochemical sensing technology
With RealTest technology, the CO gas sensing cell of the
COI 224T CO detector can be tested using a carbon monoxide gas
agent. Simply hold the test button for two seconds. After the alarm
cycle (temp 4) the green LED will flash about once per second,
indicating that the detector is ready to accept CO for testing.
Spray a small amount of CO into the detector per the installation
instructions, and within seconds the detector will alarm, indicating
successful gas entry.
If dangerous amounts of carbon monoxide is detected, the C01 224T
detector will alert residents by sounding and flashing a temp -4 signal
alarm. Protection is guaranteed 24/7 by a central station, regardless
of whether residents are away from home, sleeping or already
suffering from the effects of CO.
This specific device is designed for system operation. The detector is
fully listed to UL 2075. It offers a code required trouble relay to send
a sensor failure or end -of -life signal to the control panel and the
central station. It also uses SEMS -type terminal Philips head screws
to provide a quicker and more positive wiring connection and code
required wiring supervision.The COI 224T detector offers a low
current draw, allowing more devices to be connected to the panel
without having to purchase a more expensive panel or an extra
power supply.
The COI 224T model will operate on most industry security and fire
Agency Listings alarm control panels because it is is a 12/24 VDC detector.
U`
LISTED
C01 224T Carbon Monoxide Detector Specifications
Carbon monoxide detector shall be a System Sensor model number COI 224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and
Sensors.The detector shall be equipped with a sounder and a trouble relay. The detector's base shall be able to mount to a single -gang electrical box or direct
(surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which
blinks to indicate normal standby, alarm, or end -of -life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the
panel. When the detector gives a trouble or end -of -life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO
sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.
Operating Voltage 12/24 VDC
Audible Signal 85 dB in alarm
Standby Current 20 mA
Alarm Current 40 mA (75 mA test)
Alarm Contact Ratings 0.5 A @ 30 VDC
Trouble Contact Ratings
Specifications
0.5 A @ 30 VDC
i Physical
Size
Length: 5.1 in, Width: 3.3 in, Height: 1.3 in
Approximate Weight
7 oz
Operating Temperature Range
32°F to 104° F (0 °C to 40° C)
Operating Humidity Range
22 to 90%RH
Input Terminals
14 to 22 AWG
Mounting
Single -gang back box, surface mount to wall or ceiling
Modes
Normal (standby) Blink 1 per minute — —
Alarm — Blink in temp 4 pattern Sound in temp 4 pattern
Rearrest" Feature: The System Sensor COI 224T carbon monoxide detector with Rearrest" can evaluate the functionality of the CO sensing cell using
canned test agent.
Push and hold theTest/Hush button for Spray canned CO agent into the detector. Verify CO sensing at the control panel. The
two seconds to enter Rearrest mode. The detector will automatically exit Rearrest
green LED will flash once every second to alarm mode after about 20-60 seconds.
indicate RealTest mode has started.
NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation.
Hush Feature: Pushing the Test /Hush button will silence the sounder for 5 minutes (except in RealTest mode).
Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel.
End -of -life Timer: After the detector's internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is
time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must
be replaced by the date marked on the inside of the product.
Ordering Information
C01224T 12/24 volt, 4 -wire system- monitored carbon monoxide detector with RealTest Technology
S YSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Pd ozooasrn. d s An ,
SENSOR' n, rod —H a�ro�a�g� ��—
Phone: 800 SENSOR2 •Fax: 630 377 6495 Re 1 n' °�° ^b^^r�° 3 7.OW - aM - n.5 dasa n..c
A05-04 # 1953
Honeywell
Piezo Dynamic Series
(PD) SIRENS
WAVE2PD
Honeywell's Piezo Dynamic (PD) WAVE2PD and 747PD
Sirens produce traditional "speaker" sound while drawing
1/4 the current of typical sirens. This allows multiple
devices to be installed on the same alarm panel without
the need for additional hardware, costs and labor.
FEATURES
CE
747PD
The sirens feature a sleek, lightweight design, an
easy -to -wire terminal block and a hinged case cover.
The WAVE2PD and 747PD Sirens are globally compliant
and UL approved and ideal for residential application.
• Low current draw lets you add additional sirens in areas • Hinged case cover with elliptical mount holes provide
like basements, garages, hallways and more installation convenience
• Two tones to choose from: Steady and Warble • Tampered versions available to provide an added level of
• Lightweight ABS plastic case is less than half the weight protection and meet global requirements
of standard sirens • Compatible with LYNX control panels
• Enclosed PCB to protect components • Large wiring channel provides plenty of room for wire
• Easy -to -wire terminal block eliminates the need to splice
and crimp wire
Dimensions: See reverse side for dimensional drawings and ordering information
Piezo Dynamic Series
(PD) SIRENS
SPECIFICATIONS
WAVE2PD o.ss" -1ao•
Sound Output 1.40
• 105dB @ 1 meter
i �� � 0.15'
Current Draw
• 120mA ` 14�s
4.46'
/ 3.15"
Operation Voltage+
• 12VDC'` a
\j
325•
Dimensional Drawing for WAVE2PD Siren
747PD 1.25• 015
Sound Output �
N0
• 105dB @ 1 meter
Current Draw
4.25"
• 120mA
Operation Voltage I \
• 12VDC flv
4.25"
Dimensional Drawing for 747PD Siren
ORDERING
WAVE2PD
Piezo Dynamic Siren
WAVE2PDT
Piezo Dynamic Siren with Tamper
747PD
Piezo Dynamic Siren
747PDT
Piezo Dynamic Siren with Tamper
Honeywell Security & Custom Electronics
Honeywell International Inc.
PO Box 9035
Syosset, NY 11791
www.honeywell.com
PL06005
UPIEZODYN/D
May 2006
02006 Honeywell International Inc.
3.25"
Honeywell
Honeywell
VISTA -50P
CONTROL PANEL
l�
L I- N�l
F �-
Honeywell's VISTA -50P Control Panel provides the flexibility of up to eight independent partitions with the economy
of a single control.
FEATURES
Dependable features to meet your most
demanding installations:
• Nine hardwired zones standard
• Expandable to 87 total zones
• Eight partitions standard
• 75 user codes work in all partitions
• Seven authority levels
• 224 event memory log /printer option
• Four trigger outputs
• 5800 Series wireless compatibility
• Supports two -wire multiplex
• Scheduling of events (real time clock)
• Keypad macro features
• Master console option for viewing all
partitions at a glance
• Common lobby logic
• Fast downloading
• Supports up to 16 relays and /or X -10
• Quick start programming
• False alarm features
• UL Commercial Burglary listed
(VISTA- 50PUL)
End users will appreciate the easy -to -use
convenience and control features of the VISTA -50P:
• Wireless remote controls
(featuring single button system operation):
— 5804 - Four -Button Wireless Key
— 5804BD - Bidirectional
Four -Button Wireless Key with
system status feedback
• Single or dual- button wireless
personal panic:
— 5802MN
— 5802MN2
• Home control features activate lights, appliances,
garage doors and numerous other devices
• The VISTA Interactive Phone Module (VIP) gives the
end -user control of their system from any touchtone
phone. The 4286 VIP responds in English, with a
vocabulary of over 100 words
• Full English display keypads for clear understanding
of system status and zone locations
• Timed event applications:
— Opens garage doors and
turns on lights
— Provides "lived -in look" while
away from home
— Ability to limit access to parts of the
home at certain times
VISTA -50P
CONTROL PANEL
SPECIFICATIONS
Electrical
• Aux power 12VDC, 750mA max
• 16.5 VAC /40 VA transformer
• Alarm output 12VDC,
1.7 Amps max
• For UL installations, combined
Aux and alarm output cannot exceed
750mA
Output Control
• Supports up to four relay boards
(Part No. 4204)
• Each board supports four relays
for a total of 16
• Optional X -10 interface (Part No.
4300) may be used to control
X -10 receiving devices
• Each X -10 receiver address
counts as one relay when computing
total relays
• Real time clock can be used for
relay/X -10 control
Zones
• Nine hardwired zones
• Selectable response on zone 9:
10MSec or 500MSec
• Assignable to any partition
• 14 zone types to choose from
• Programmable swinger suppression
Communications
• Touchtone or pulse
• Formats supported: ADEMCO
Contact ID, ADEMCO 4 + 2 Express,
ADEMCO low speed
• 3 +1, 4 +1 and 4 +2 reporting
• Reporting capabilities: Split,
Dual, Split/Dual
• Low battery reports 11.2- 11.6VDC
• Expanded reporting
• Up to four digit PABX
codes supported
• True dial tone detection
• Double pole line seizure
• AC loss and restoral
reporting supported
Supported Devices
Hardwired Expansion Devices
• 4208U Eight -Zone
Expansion Module
• Keypads
— 6139 Custom English (required for
programming) -100mA
— 6128 Fixed English LCD - 30mA
• Voice Module 4286 VIP -160mA
• Two -Wire Smoke Detectors
• Duct Detectors
• Serial Printer
• Polling Loop Devices
• Key Switch Devices
Wireless Receiver Systems
• 5800 Series
— 5881 ENL up to 8 zones -50mA
— 5881 ENM up to 16 zones -50mA
— 5881 ENH up to 26 zones -50mA
• All Receivers Support:
— Diversity reception with
two antennea
— Remote mounting for
best location
— Use of second receiver for
maximum coverage or
tough installations
— Unique supervision and low
battery indications by point
Transmitters
• 5800 Series
— Three volt Duracell lithium batteries
— One mile range
— Tamper standard
Agency Listings
• UL Residential Fire and Burglary
and CSFM
• UL Commercial Burglary
(VISTA- 50PUL)
ORDERING
VISTA -50P Control Panel
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
www.honeywell.com
LNIS50P /D
September 2008
0 2008 Honeywell International Inc.
Honeywell