Loading...
HomeMy WebLinkAboutM10-0305NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWNOFVR ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 416 VAIL VALLEY DR VAIL Location.....: UNIT 16, RAMSHORN Parcel No...: 210108258024 OWNER TYM INTERNATIONAL LTD 12/13/2010 416 VAIL VALLEY DR VAIL CO 81657 APPLICANT WESTERN FIREPLACE SUPPLY, IN 12/13/2010 Phone: 668 -3760 1685 PAONIA COLO SPRINGS, CO 80915 PO BOX 670 MINTURN, CO 81645 License: 323 -M CONTRACTOR WESTERN FIREPLACE SUPPLY 1685 PAONIA COLO SPRINGS, CO 80915 PO BOX 670 MINTURN, CO 81645 License: 323 -M IN 12/13/2010 Phone: 668 -3760 Desciption: INSTALL ONE PRECAST MASONRY FIREPLACE WITH GAS LOGSET. FIREPLACE MODEL MFP -44, LOGS MODEL BT -30 Valuation: $8,020.00 Permit #: M10 -0305 Project #: PRJ09 -0697 Status ...: ISSUED Applied..: 12/13/2010 Issued. .: 01/05/2011 Expires . .: 07/04/2011 Mechanical Permit Fee --- > $180.00 Will Call ------------ > $5.00 Total Calculated Fees --- > $230.00 Plan Check ------------------- > $45.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00 Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $230.00 Total Calculated Fees - -> $230.00 Payments ----- — ---------- > $230.00 BALANCE DUE --------- > $0.00 Item: 05100 BUILDING DEPARTMENT 01/04/2011 Martin Action: AP APPROVALS Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. N REQUESTS FOR IN N SHALE13 HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01 AM-4 - -- s� r Sig a of Owner or Contractor r_5 4e_ Print Name mechcan ical_permit_041908 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement Statement Number: R110000019 Amount: $229.00 01/06/201111:16 AM Payment Method: Check Init: LC Notation: #2744 / WESTERN FIRE PLACE SUPPLY ----------------------------------------------------------------------------- Permit No: M10 -0305 Type: MECHANICAL PERMIT Parcel No: 2101 - 082 - 5802 -4 Site Address: 416 VAIL VALLEY DR VAIL Location: UNIT 16, RAMSHORN Total Fees: $229.00 This Payment: $229.00 Total ALL Pmts: $229.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts --------- ----- - - - - -- ------------------------ - - - - -- ------ MP 00100003111100 MECHANICAL PERMIT FEES - - - - -- 180.00 PF 00100003112300 PLAN CHECK FEES 45.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 12/08/2010 10:20 ❑ Complete Mech o Combustion Air a. Flue detail or V o Gas Plping layo ❑ Neat Loss CaICL 9708279222 WESTERN FIREPLACE PAGE 01 '-4`} . rj.• 'v r: ,,,?:t,•. ��;C:,` .�j6'?, :, f,:�,1':; ^�`�•. ;i�kE< �'4:L'::? „J' ..J .'ti '��'' eS +IC,. l R�' �'Cr ,s► ►: `'', :�.';'� . : fi5 SCtuth Fr 9 - MECHANICAL PERMIT der / Furnace & Fireplace Applications MUST include.- ical Room Floor Plan with Dimensions o Boller size & efficiency ict Size and Location o Equipment Cut Sheets for Fireplaces /Log Sets L size, location & termination including development length calculations Project Street Add as: L (Number) (Stree ) Building /Complex I Contractor Informa Company: Company Address: . City: A VCS r( Contact Name: Contact Phone: E-Mail TOE@ Town of Vall Conti Property Informatlo Parcel #: (For parcel *, contact E; visit www.eaglecounty.0 Tenant Name: Owner Name: Complete Valuation Mechanical $; (Suite #) MKS WOLd Lo N�S� Manufacturer Info showing make, model & approval listin Office Use: /�c. ✓ 'vooY Project #: Building Permit #: 75 5:� 9 - 3 t - 7 Mechanical Permit #: — c) C 1 5 Lot #; Block # Subdivision: Define Scope and Location of Work: /n1 - rAC.L OA on: ' PELCLST MLS LY F �P C • LJ�P,�P� -c€ S� PP�Y ; .r b goK ftz z M ? S Lo S�i� FIE MK).EL '' M�P i state: Go zip: M ODE L " �, C) (uae additional sheet if necessary) a Gas Piping Included Gas Piping by Others ; ,ST I i� Pt . CO t-1 Wood to Gas Fireplace Conversion )r Registration No.: 3 Z M 'Boiler Location: w. V �< ...w•. _ ..M� <i i Interior Exterior ( ) Other ( ) (required) _ Number of Existing Fireplaces: ,.w..�,_ „_..,_..,....,..,. _,,.., Gas Appliances Gas Logs Wood /Pellet Number of Proposed Fireplaces: gla County Aseessors Office at 970 - 328 -8840 or Gas Appliances Gas Logs Wood /Pellet Ipaft) t Type of Building: nmercial Properties) Single -Family ( )Duplex ( )Multi - Family (�) Commercial ( ) !'Restaurant( ) Other( ) __..,.__.,...,._,:_. _,_..,.., ,.,...........,..., ...,.._.: t Date Received: rMechanlcal Permit: (including fire�lacas) 8 DEC 0 2010 TOWN OF VL Iing�necbaaiceJ�ernuc 0),OI10 12/08/2010 10:20 9708279222 WESTERN FIREPLACE PAGE 02105 Report No. 2401 REV 09/28109 NMINS Instructions by MR • Masonry Flreplace Industries, LLB f7n k 0 0 0 M asonry Firebo Models MFP- 33/39/44/49/63 THIS WOOD-BUR14ING FIREPLACE COMPLIES WITH UL127 STANDARD AS A FACTORY -BUILT APPLIANCE. AWARNING: THIS FIREPLACE IS APPROVED FOR USE AS A WOOD BURNING FIREPLACE. IT HAS NOT BEEN TESTED OR APPROVED FOR UNVENTED GAS LOGS. AWARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY, PROPERTY DAMAGE OR LOSS OF LIFE. REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION. CONSULTA QUALIFIED INSTALLER OR LOCAL DISTRIBUTOR. SAVE THIS BOOK This book is valuat le. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep with your other Important papers. nd that our gas Cts be installed yprolessionals FIREPLACE W e recomm fKSTlTUTr hearth prodL CM andserviced are cer fled In the U.S. V 1#10 by the Nalonal InsUlutO (N CEROW2 Speclallsts. Fireplace � 1) as NFI Gas Report No. 08-1 or other flammable vapors and Do not store gasoline liquids in the vicinity of this or any other appliance. IM Fvmhintinn Services Report No. 2401 REV 09/28109 12/08/2010 10: 9708279222 WESTERN FIREPLACE Mason L MFP -39144/49 Fireplace Overall Dimensions Fissure E +I r- 4" NO H 11 " 28" 10" 21 23" A/2 I C 4 1/4 A E �_ 4 3/8" —• 63 1/2') 327/811 40 5 /8" H Fireplace Overall Dimensions Model A B C D E F MFP -39 43" 39" 30 -1/4" 27 -3/4" 38 -3/4" 012" MFP-44 48" 44" 5 -1 /4 35-1 32 -3/4° 43 -314" 012" MFP -49 53" 49" 40 - 1/4" 37 -3/4" 48 -3/4" 014" PAGE 03/05 0 12/08/2010 10: by Please Gas logs are to be • For best results, n. column. • To simulate real v yellow flame, It is removed %vith a va • A fireplace screen and, unless other l shall have an open • If used with glass • Do not burn wood Log sets are designed designed for Natural i The installation, inclui tion air, must conforrn codes, with the nation; NFPA54 -1988. The appliance and its ed from the gas supp] in excess of 1/2 psig. 9708279222 WESTERN FIREPLACE INSTALLER! PLEASE LE"E WITH HOMEOWNER INSTALL AND OPERATING INSTRUCTIONS "BIG TEX" VENTED GAS LOGS 0 xtv�� PAGE 04/05 It its important that you read instructions before iiu tstalling or operating gas logs GENERAL INFORMATION only in approved woodburning Fireplace with adequate chimney draft. When burning, the F mne� )PEN. Log set must be installed in fireplace which operates properly wbcn wood fires are burned. gas pressure must be. 7 to 10 -1/2" water I burning, the gas burner is designed to burn a rural for the logs to soot -up. The soot can easily be im cleaner or a soft brush. tst be in place when the appliance is operating risions for combustion air are provided, the screen (s) for introduction of combustion air. place doors, burn with doors in open position. other items with log set. FOR YOUR SAFETY If you smell gas: 1. Open Windows, 2. Don't `roueb electrical switches. 3. Extinguish any open flame. 4. Immediately call your gas supplier. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ■�� IMPORTANT INFORMATION CHECK TO BE SURE LOG SET IS FOR PROPER GAS TYPE use with Natural Gas, unless clearly labeled for Propane (LP). Never use Propane Gas in a log set or Natural Gas in a log set designed for use with Propane Gas, 19 provisions for combustion and ventila- lith local codes or, in the absence of local fuel Gas Code, ANSI 2223.1 -1988 and tdividual shutoff valve must be disconnect - piping system when testing at test pressures The appliance must be isolated from the gas supply piping system by closing its individiii I manual shutoff valve during any pressure testing of gas - supply s stem at test pressures equal to or less than 1/2 psig. Tiis is accomplished by closing the gas sup- ply line valve, which i required by NFPA 54, section 5.54. The minimum inlet gas supply pressuue for the purpose of input adjustment is 7" WC for Natural Gas and I I WC for Propane Gas. The maximum inlet gas supply pressure for this burner is 10.5" for Natural Gas and 13" for Propane Gas. IMPORTANT: MINIMUM SPECIFICATIONS LISTED IN THE CHART ON PAGE 2 OF THESE INSTRUCTIONS MUST BE MET TO SAFELY INSTALL AND OPERATE THIS GAS LOG SET. 12/08/2010 10:20 9708279222 WESTERN FIREPLACE PAGE 05/05 6. Gas Con 7. Damper Clamp 8. Control Tool (Adjustable lower burner) NOTE: "Big Tex ceramic gas logs are packaged 'n separate cartons. Individual logs and log arranage- meut inst uctions are supplied in log car ns. *The gas fittings s pp lied are for what the factory considers a ' SPECIFICATIONS may require a longer connector tube or Dtherfittings available in most hardware tores. MODEL # MINIMUM MINIMUM SEE -THRU OVERALL MINIMUM MINIMUM REQUIRED REQUIRED MINIMUM HEIGHT REQUIRED REQUIRED WIDTH DEPTH DEPTH WITH LOGS BTU GAS PIPING B 24 34" 20" 24" 18" 80,000 1/2" I.D, BT30 40° 20" 28" 1B 90,000 1/2° I.D. BT36 46 11 22" 28" 20" 120,000 1/2" I.D. BT42 52" 22" 28" 24" 140,000 3/4" I.D. BT48 58" 22" 28" 24" 160,000 3/4" I.D. BT60 70" 22" 28" 24" 180,000 1" I,D. BT72 82" 22" 28" 24" 220,000 1" I.D. Raised Rear / Burner Components Parts Flame Ca m Down Tube ITEM 1. 2 -Stage Burr er Assembly 2. Silica Sand (Used in raised rear burner - Nat. Gas) 3. Glowing Embers 4. Black Volcanic Cinders 5. Vermiculite ( sed in raised rear burner - LP Gas and used on top of low gr adjustable burner - Nat. & LP Gas) Q 6. Gas Con 7. Damper Clamp 8. Control Tool (Adjustable lower burner) NOTE: "Big Tex ceramic gas logs are packaged 'n separate cartons. Individual logs and log arranage- meut inst uctions are supplied in log car ns. *The gas fittings s pp lied are for what the factory considers a normal iustaUation. Some installations may require a longer connector tube or Dtherfittings available in most hardware tores. Lower Lower Burner Adjuslable /Adjustment Burner Valve C 6 7 cm L.P. SET$ MUST INCLUDE GB FACTORY INSTALLED SAFETY PILOT KIT z 1(? -21 -2011 Inspection Request Re - Page 15 4:16 pm Vail, CO - CltV O Requested Inspect Date: Mondayy, October 24 2011 Site Address: 416 VA T VALLEY D�2 VAIL UNIT 16, RAMSHORN A/P /D Information Activity: M10 -0305 Type: B -MECH Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: TYM INTERNATIONAL LTD Contractor: WESTERN FIREPLACE SUPPLY, INC. Phone: 668 -3760 Description: INSTALL ONE PRECAST MASONRY FIREPLACE WITH GAS LOGSET. FIREPLACE MODEL MFP -44, LOGS MODEL BT -30 Requested Insaectionls Item: 390 MECH -Final Requestor: WESTERN FIREPLACE SUPPLY, INC. Comments: 47 -1891 Assigned To: ON Action: Time Exp: _ Requested Time: 03:00 PM Phone: 970 - 668 -3760 -or- 970 -827- 9623 Entered By: JMONDRAGON K Inspection Histo Item: 200 MECH -Rough ** Approved ** 03/23/11 Inspector: JRM Comment: APPROVED FIRE PLACE Item: 310 MECH- Heating Item: 315 PLMB -Gas Piping Item: 320 MECH - Exhaust Hoods Item: 330 MECH - Supply Air Item: 340 MECH -Misc. Item: 390 MECH -Final Action: AP APPROVED REPT131 Run Id: 13684