HomeMy WebLinkAboutM10-0305NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MWNOFVR '
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
MECHANICAL PERMIT
AMF
Job Address: 416 VAIL VALLEY DR VAIL
Location.....: UNIT 16, RAMSHORN
Parcel No...: 210108258024
OWNER TYM INTERNATIONAL LTD 12/13/2010
416 VAIL VALLEY DR
VAIL
CO 81657
APPLICANT WESTERN FIREPLACE SUPPLY, IN 12/13/2010 Phone: 668 -3760
1685 PAONIA
COLO SPRINGS, CO 80915
PO BOX 670
MINTURN, CO 81645
License: 323 -M
CONTRACTOR WESTERN FIREPLACE SUPPLY
1685 PAONIA
COLO SPRINGS, CO 80915
PO BOX 670
MINTURN, CO 81645
License: 323 -M
IN 12/13/2010 Phone: 668 -3760
Desciption: INSTALL ONE PRECAST MASONRY FIREPLACE WITH GAS LOGSET.
FIREPLACE MODEL MFP -44, LOGS MODEL BT -30
Valuation: $8,020.00
Permit #: M10 -0305
Project #: PRJ09 -0697
Status ...:
ISSUED
Applied..:
12/13/2010
Issued. .:
01/05/2011
Expires . .:
07/04/2011
Mechanical Permit Fee --- > $180.00 Will Call ------------ > $5.00 Total Calculated Fees --- > $230.00
Plan Check ------------------- > $45.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00
Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $230.00
Total Calculated Fees - -> $230.00 Payments ----- — ---------- > $230.00
BALANCE DUE --------- > $0.00
Item: 05100 BUILDING DEPARTMENT
01/04/2011 Martin Action: AP
APPROVALS
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
N
REQUESTS FOR IN N SHALE13 HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01
AM-4 - --
s� r
Sig a of Owner or Contractor r_5 4e_
Print Name
mechcan ical_permit_041908
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO
Statement
Statement Number: R110000019 Amount: $229.00 01/06/201111:16 AM
Payment Method: Check Init: LC
Notation:
#2744 /
WESTERN FIRE PLACE SUPPLY
-----------------------------------------------------------------------------
Permit No: M10 -0305 Type: MECHANICAL PERMIT
Parcel No: 2101 - 082 - 5802 -4
Site Address: 416 VAIL VALLEY DR VAIL
Location: UNIT 16, RAMSHORN
Total Fees:
$229.00
This Payment: $229.00 Total ALL Pmts:
$229.00
Balance:
$0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
--------- ----- - - - - -- ------------------------ - - - - -- ------
MP 00100003111100 MECHANICAL PERMIT FEES
- - - - --
180.00
PF 00100003112300 PLAN CHECK FEES
45.00
WC 00100003112800 WILL CALL INSPECTION FEE
4.00
12/08/2010 10:20
❑ Complete Mech
o Combustion Air
a. Flue detail or V
o Gas Plping layo
❑ Neat Loss CaICL
9708279222
WESTERN FIREPLACE PAGE 01
'-4`}
. rj.• 'v r: ,,,?:t,•. ��;C:,` .�j6'?, :, f,:�,1':; ^�`�•. ;i�kE< �'4:L'::? „J'
..J .'ti '��'' eS +IC,. l R�' �'Cr
,s► ►: `'', :�.';'� . : fi5 SCtuth Fr 9
-
MECHANICAL PERMIT
der / Furnace & Fireplace Applications MUST include.-
ical Room Floor Plan with Dimensions o Boller size & efficiency
ict Size and Location o Equipment Cut Sheets for Fireplaces /Log Sets
L size, location & termination
including development length calculations
Project Street Add as:
L
(Number) (Stree )
Building /Complex I
Contractor Informa
Company:
Company Address: .
City: A VCS r(
Contact Name:
Contact Phone:
E-Mail TOE@
Town of Vall Conti
Property Informatlo
Parcel #:
(For parcel *, contact E;
visit www.eaglecounty.0
Tenant Name:
Owner Name:
Complete Valuation
Mechanical $;
(Suite #)
MKS WOLd Lo N�S�
Manufacturer Info showing make, model & approval listin
Office Use: /�c. ✓ 'vooY
Project #:
Building Permit #: 75 5:� 9 - 3 t - 7
Mechanical Permit #: — c) C 1 5
Lot #; Block # Subdivision:
Define Scope and Location of Work: /n1 - rAC.L OA
on: ' PELCLST MLS LY F �P C •
LJ�P,�P� -c€ S� PP�Y ; .r
b goK ftz z M ? S Lo S�i� FIE MK).EL '' M�P
i
state: Go zip: M ODE L " �, C)
(uae additional sheet if necessary)
a Gas Piping Included
Gas Piping by Others ;
,ST I i� Pt . CO t-1 Wood to Gas Fireplace Conversion
)r Registration No.: 3 Z M 'Boiler Location: w. V �< ...w•. _ ..M� <i
i Interior Exterior ( ) Other ( )
(required) _
Number of Existing Fireplaces:
,.w..�,_ „_..,_..,....,..,. _,,.., Gas Appliances Gas Logs Wood /Pellet
Number of Proposed Fireplaces:
gla County Aseessors Office at 970 - 328 -8840 or Gas Appliances Gas Logs Wood /Pellet
Ipaft)
t Type of Building:
nmercial Properties) Single
-Family ( )Duplex ( )Multi - Family (�) Commercial ( )
!'Restaurant( ) Other( )
__..,.__.,...,._,:_. _,_..,.., ,.,...........,..., ...,.._.: t Date Received:
rMechanlcal Permit: (including fire�lacas)
8
DEC 0 2010
TOWN OF VL
Iing�necbaaiceJ�ernuc 0),OI10
12/08/2010 10:20 9708279222 WESTERN FIREPLACE PAGE 02105
Report No. 2401
REV 09/28109
NMINS Instructions
by MR • Masonry Flreplace Industries, LLB
f7n
k 0 0 0
M asonry Firebo
Models MFP- 33/39/44/49/63
THIS WOOD-BUR14ING
FIREPLACE COMPLIES WITH UL127 STANDARD AS A FACTORY -BUILT APPLIANCE.
AWARNING: THIS
FIREPLACE IS APPROVED FOR USE AS A WOOD BURNING FIREPLACE.
IT HAS NOT BEEN
TESTED OR APPROVED FOR UNVENTED GAS LOGS.
AWARNING: IMPROPER
INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY, PROPERTY
DAMAGE OR LOSS OF LIFE. REFER TO THIS MANUAL FOR ASSISTANCE OR
ADDITIONAL INFORMATION.
CONSULTA QUALIFIED INSTALLER OR LOCAL DISTRIBUTOR.
SAVE THIS BOOK
This book is valuat
le. In addition to instructing you on how to install and maintain your appliance, it also contains
information that will
enable you to obtain replacement parts or accessory items when needed. Keep with your other
Important papers.
nd that our gas
Cts be installed
yprolessionals
FIREPLACE W e recomm
fKSTlTUTr hearth prodL
CM andserviced
are cer
fled In the U.S.
V
1#10 by the Nalonal
InsUlutO (N
CEROW2 Speclallsts.
Fireplace �
1) as NFI Gas
Report No. 08-1
or other flammable vapors and
Do not store gasoline
liquids in the vicinity
of this or any other appliance.
IM Fvmhintinn Services
Report No. 2401
REV 09/28109
12/08/2010 10:
9708279222
WESTERN FIREPLACE
Mason L MFP -39144/49 Fireplace Overall Dimensions
Fissure
E +I r- 4"
NO
H
11 "
28"
10" 21
23"
A/2 I C
4 1/4
A E
�_
4 3/8" —•
63 1/2')
327/811 40 5 /8"
H
Fireplace Overall Dimensions
Model
A
B
C
D
E
F
MFP -39
43"
39"
30 -1/4"
27 -3/4"
38 -3/4"
012"
MFP-44
48"
44"
5 -1 /4
35-1
32 -3/4°
43 -314"
012"
MFP -49
53"
49"
40 - 1/4"
37 -3/4"
48 -3/4"
014"
PAGE 03/05
0
12/08/2010 10:
by
Please
Gas logs are to be
• For best results, n.
column.
• To simulate real v
yellow flame, It is
removed %vith a va
• A fireplace screen
and, unless other l
shall have an open
• If used with glass
• Do not burn wood
Log sets are designed
designed for Natural i
The installation, inclui
tion air, must conforrn
codes, with the nation;
NFPA54 -1988.
The appliance and its
ed from the gas supp]
in excess of 1/2 psig.
9708279222
WESTERN FIREPLACE
INSTALLER! PLEASE LE"E WITH HOMEOWNER
INSTALL AND OPERATING INSTRUCTIONS
"BIG TEX" VENTED GAS LOGS
0 xtv��
PAGE 04/05
It its important that you read instructions before iiu tstalling or operating gas logs
GENERAL INFORMATION
only in approved woodburning Fireplace with adequate chimney draft. When burning, the F mne�
)PEN. Log set must be installed in fireplace which operates properly wbcn wood fires are burned.
gas pressure must be. 7 to 10 -1/2" water
I burning, the gas burner is designed to burn a
rural for the logs to soot -up. The soot can easily be
im cleaner or a soft brush.
tst be in place when the appliance is operating
risions for combustion air are provided, the screen
(s) for introduction of combustion air.
place doors, burn with doors in open position.
other items with log set.
FOR YOUR SAFETY
If you smell gas:
1. Open Windows,
2. Don't `roueb electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
■�� IMPORTANT INFORMATION
CHECK TO BE SURE LOG SET IS FOR PROPER GAS TYPE
use with Natural Gas, unless clearly labeled for Propane (LP). Never use Propane Gas in a log set
or Natural Gas in a log set designed for use with Propane Gas,
19 provisions for combustion and ventila-
lith local codes or, in the absence of local
fuel Gas Code, ANSI 2223.1 -1988 and
tdividual shutoff valve must be disconnect -
piping system when testing at test pressures
The appliance must be isolated from the gas supply piping system
by closing its individiii I manual shutoff valve during any pressure
testing of gas - supply s stem at test pressures equal to
or less than 1/2 psig. Tiis is accomplished by closing the gas sup-
ply line valve, which i required by NFPA 54, section 5.54.
The minimum inlet gas supply pressuue for the purpose
of input adjustment is 7" WC for Natural Gas and I I
WC for Propane Gas.
The maximum inlet gas supply pressure for this burner
is 10.5" for Natural Gas and 13" for Propane Gas.
IMPORTANT: MINIMUM SPECIFICATIONS
LISTED IN THE CHART ON PAGE 2 OF THESE
INSTRUCTIONS MUST BE MET TO SAFELY
INSTALL AND OPERATE THIS GAS LOG SET.
12/08/2010 10:20 9708279222 WESTERN FIREPLACE PAGE 05/05
6. Gas Con
7. Damper Clamp
8. Control Tool (Adjustable lower burner)
NOTE: "Big Tex ceramic gas logs are
packaged 'n separate cartons.
Individual logs and log arranage-
meut inst uctions are supplied
in log car ns.
*The gas fittings s
pp lied are for what the
factory considers a
'
SPECIFICATIONS
may require a longer
connector tube or
Dtherfittings available
in most hardware
tores.
MODEL #
MINIMUM
MINIMUM
SEE -THRU
OVERALL
MINIMUM
MINIMUM
REQUIRED
REQUIRED
MINIMUM
HEIGHT
REQUIRED
REQUIRED
WIDTH
DEPTH
DEPTH
WITH LOGS
BTU
GAS PIPING
B 24
34"
20"
24"
18"
80,000
1/2" I.D,
BT30
40°
20"
28"
1B
90,000
1/2° I.D.
BT36
46 11
22"
28"
20"
120,000
1/2" I.D.
BT42
52"
22"
28"
24"
140,000
3/4" I.D.
BT48
58"
22"
28"
24"
160,000
3/4" I.D.
BT60
70"
22"
28"
24"
180,000
1" I,D.
BT72
82"
22"
28"
24"
220,000
1" I.D.
Raised Rear
/ Burner
Components
Parts
Flame Ca m
Down Tube
ITEM
1.
2 -Stage Burr
er Assembly
2.
Silica Sand (Used
in raised
rear burner - Nat. Gas)
3.
Glowing Embers
4.
Black Volcanic
Cinders
5.
Vermiculite (
sed in raised
rear burner - LP Gas and used
on top of low
gr adjustable burner - Nat. &
LP Gas)
Q
6. Gas Con
7. Damper Clamp
8. Control Tool (Adjustable lower burner)
NOTE: "Big Tex ceramic gas logs are
packaged 'n separate cartons.
Individual logs and log arranage-
meut inst uctions are supplied
in log car ns.
*The gas fittings s
pp lied are for what the
factory considers a
normal iustaUation.
Some installations
may require a longer
connector tube or
Dtherfittings available
in most hardware
tores.
Lower
Lower Burner
Adjuslable /Adjustment
Burner Valve
C
6
7 cm
L.P. SET$ MUST INCLUDE GB FACTORY INSTALLED SAFETY PILOT KIT
z
1(? -21 -2011 Inspection Request Re - Page 15
4:16 pm Vail, CO - CltV O
Requested Inspect Date: Mondayy, October 24 2011
Site Address: 416 VA T VALLEY D�2 VAIL
UNIT 16, RAMSHORN
A/P /D Information
Activity: M10 -0305 Type: B -MECH Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: Insp Area:
Owner: TYM INTERNATIONAL LTD
Contractor: WESTERN FIREPLACE SUPPLY, INC. Phone: 668 -3760
Description: INSTALL ONE PRECAST MASONRY FIREPLACE WITH GAS LOGSET. FIREPLACE MODEL MFP -44,
LOGS MODEL BT -30
Requested Insaectionls
Item: 390 MECH -Final
Requestor: WESTERN FIREPLACE SUPPLY, INC.
Comments: 47 -1891
Assigned To: ON
Action: Time Exp: _
Requested Time: 03:00 PM
Phone: 970 - 668 -3760 -or- 970 -827-
9623
Entered By: JMONDRAGON K
Inspection Histo
Item: 200 MECH -Rough ** Approved **
03/23/11 Inspector: JRM
Comment: APPROVED FIRE PLACE
Item: 310 MECH- Heating
Item: 315 PLMB -Gas Piping
Item: 320 MECH - Exhaust Hoods
Item: 330 MECH - Supply Air
Item: 340 MECH -Misc.
Item: 390 MECH -Final
Action: AP APPROVED
REPT131
Run Id: 13684