Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A10-0113
TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 -479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Job Address: 1000 LIONS RIDGE LP VAIL Location.....: HOT TUB/POOL AREA, VAIL RUN Parcel No...: 210312105006 Project No OWNER VAIL RUN RESORT COMMUNITY 1000 LIONS RIDGE LOOP VAIL CO 81657 APPLICANT ACME ALARM COMPANY P.O. BOX 883 RIFLE CO 81650 License: 154 -S CONTRACTOR ACME ALARM COMPANY P.O. BOX 883 RIFLE CO 81650 License: 154 -S AS 12/14/2010 12/14/2010 Permit #: A10 -0113 Status ...: ISSUED Applied..: 12/14/2010 Issued . .: 02/23/2011 Expires. .: 08/22/2011 Phone: 970 - 625 -3398 12/14/2010 Phone: 970 - 625 -3398 Desciption: COMMON ELEMENT EMERGENCY REPAIRS: REMOVE WOOD CEILING OVER HOT TUB /POOL AREA, CLEAN UP RUST Valuation: $4,500.00 +*r* s+ a+**+******► * * * + * + + * + * *. * * * * * * *r *+ * *► * * * * *■ FEE SUMMARY + + + + * * * * * * *a ** ear *s * * * *r * * + * * * * * *w « * * * + *• + r + * * *+ Electrical --------- > $0.00 Total Calculated Fees - -> $456.75 DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00 Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $456.75 Will Call --------- > $0.00 Payments ------------------ > $456.75 TOTAL FEES - -> $456.75 BALANCE DUE--- - - - - -> $0.00 Approvals: Item: 05600 FIRE DEPARTMENT 12/14/2010 mvaughan Action: AP CONDITIONS OF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADXKNCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADO Statement Statement Number: R110000128 Amount: $456.75 02/23/201111:15 AM Payment Method: Check Init: SAB Notation: 11619 ACME ALARM ----------------------------------------------------------------------------- Permit No: A10 -0113 Type: ALARM PERMIT Parcel No: 2103 - 121 - 0500 -6 Site Address: 1000 LIONS RIDGE LP VAIL Location: HOT TUB /POOL AREA, VAIL RUN Total Fees: $456.75 This Payment: $456.75 Total ALL Pmts: $456.75 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- -------------- ---------- - - - - -- ------ - - - - -- BP 00100003111100 FIRE ALARM PERMIT FEES 168.75 PF 00100003112300 PLAN CHECK FEES 288.00 Department of Community Development 75 South Frontage Road Vail, Colorado 89657 Tel: 970-479 -2128 Fax: 970- 479 -2452 Web: www.vailgov.com Development Review Coordinator it . ; FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: (Number) (Street) ! ((Suite #) Building /Complex Name: Contractor Information: Company )'� Cj M �� ""A Q C Company Address City: `� State: Zip: ,-a Contact Name: Contact Phone: C J 7 - - c1 Is _ S i E -Mad C.��3 {C c-f t�1t c����: C" -1 �J Town of Vail Contractor Registration No.: Contractor Signature (required) Property Information Parcel # (For parcel #. contact Eagle County Assessors Office at 970- 328 -8640 or visit www eaglecounty.uslpatie) Tenant Name: ..l 3 I`;?•;�.fi r n r` Owner Name: \ �� tL , J iZ ,0 T S Complete Valuation for Fire Alarm Permit. Fire Alarm Office Use: /JQ�� / Project #. �/'� �l o ' 01;? Building Permit # 6 " � /J • ( D55 /T Alarm Permit #: A /0 - 0113 Lot # Block # Subdivision. Detailed Desc ription of Work: iYk e (use additional sheet if necessary) Does a Fire Alarm Exist? Yes ( No( ) Does a Sprinkler System Exist? Yes No( ) Work Class: New ( } Addition ( ) Remodel Repair Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial Restaurant { ) Other( ) Date Received: 29- L AN-0') COOPER Notification E;$15' Finally, Design and Safety Meet... Ceiling Wall Description: The Wheelock° ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock° ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock° ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation ** U U Sleek Modern Aesthetics 4i Finger Slide Switches Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95,99 dB 8 Candela Settings ** Wall - 15/1575/30/75/95 /110/135/185 Ceiling - 15/30/60/75/95/115 /150/177 U Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built -in Wheelock Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range Compared to competitive models "' Patented " Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range ". • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (± 2 %) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Strobe Ratings per UL Standard Low Current 1971 Draw = Fewer Power 95 dB 90 dB UL Max Current* 24 VDC / 24 FWR 16 -33.0 12 VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0 -33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 Model Regulated Voltage 0.253 0.110 0.140 STC 8.0 -33.0 0.061 115 0.085 0.103 0.135 0.163 15 15/75 0.182 Range VDC 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16 -33.0 0.064 0.044 0.022 HNC 16 -33.0 0.084 0.044 0.022 UL Max Current* at .. dB. 0.047 0.026 0.017 HNC 8.0 -17.5 0.047 0.026 0.017 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC 10.125 HS 8.0 -33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0 -33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 UL Max Current* at 95 dB. 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0 -33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0 -33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 UL Max Current* at •• •:A 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0 -33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0 -33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL 464 Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16 -33.0 0.064 0.044 0.022 HNC 16 -33.0 0.084 0.044 0.022 FIN 8.0 -17.5 0.047 0.026 0.017 HNC 8.0 -17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16 -33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information * *UMB = Universal Mounting Base NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. *12 VDC models feature 15 & 15/75 settings Sync w/ SM, Strobe Mounting Model Candela DSM or 12/24 VDC* Options PS -6 & PS -8 H S R 15/1575/30/75/95 /110/135/185 X X U M B ** • HSW • 15/1575/30/75/95 /110/135/185 X X UMB ** HSRC 15/30/60/75/95/115 /150/177 X X UMB ** HSWC 15/30/60/75/95/115 /150/177 X X UMB ** STR 15/1575/30/75/95 /110/135/185 X X UMB ** STW 15/1575/30/75/95 /110/135/185 X X UMB ** • STRC 15/30/60/75/95/115 /150/177 X X UMB ** ' STWC . 15/30/60/75/95/115 /150/177 X X UMB ** ' HNR • �, X X UMB ** HNW X X UMB ** HNRC X X UMB ** HNWC •• X X UMB ** * *UMB = Universal Mounting Base NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. *12 VDC models feature 15 & 15/75 settings Architects and Engineers Specifications The notification appliances shall be Wheelock ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing- Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged LexanO lens. The Series shall be of low current design. Where Multi - Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous ortemporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single -gang, double -gang, 4 -inch square, 3.5 -inch octal, 4 -inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built -in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non - synchronized flash -rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances — UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC Ceiling Appliances — UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3YEAR WARRANTY Exceder - Spec Sheet 11/09 Cooper Notification is Wheelock® MEDC SAFEPATH` 0 SILENT KNIGHT by Honeywell HFS -P and HFS -PT Intelligent Photoelectric Smoke Sensors with Plug in Detector Base The HFS -P is an intelligent photoelectric smoke detector and the HFS -PT is an intelligent photoelectric smoke detector with thermal. These plug -in addressable smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight Model 5600 IntelliKnight Fire Alarm Control Panel (FACP). For more information about the IntelliKnight Model 5600 system, or to locate your nearest source, please call 800 - 328 -0103. Description The models HFS -P and HFS -PT are plug -in type smoke sensors with a plug -in detector base that combine a photoelectric sensing chamber with addressable - analog communications. The sensors transmit an analog representation of smoke density over a communication line to a control panel. An LED on the sensor is controlled by the panel to indicate sensor status. Model HFS -PT combines a photoelectric sensing chamber and 135° F (57.2° C) fixed temperature heat detector. These detectors are intended for use with model 5600 Intelligent system. Features • An LED indicates sensor status • Sleek, low- profile design • Rotary address switches for fast installation • Superior EMI resistance for reliability • Variety of mounting options to meet any application • Plug -in mounting provides ease of installation • Tamper -proof feature available on mounting bases • Plug -In base included • Rotary address switches for fast installation • Analog communications • Tamper resistant tab available on mounting base • ETL and UL Listed Mounting Information: 4" (102 mm) square box with or without plaster ring; Minimum Depth — 1 ( 38 mm) 4" Octagon Box; Minimum Depth — 1 ( 38 mm) 3 Octagon Box; Minimum Depth — 1'/z' (38 mm) Single Gang Box; Minimum Depth — 1 ( 38 mm) Specifications Electrical Operating voltage: 15 to 32 VDC Standby Current: 300p @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC (LED on) Environmental: Operating Temperature HFS -P: 32 — 120 °F (0 °C — 49 °C) HFS -PT: 32 — 100 °F (0 °C — 38 °C) Humidity: 10% — 93% non - condensing Physical Diameter: 6.1" (155 mm) Height: 2.0" (51 mm) Weight: 5.7oz. (162g) Compatibility The HFS -P and HFS -PT, Honeywell Fire Systems detectors, are compatible with the model 5600 Addressable fire control panel. You cannot use Hochiki or SK device type protocols on the 5600 SLC loop. Model HFS -P and HFS -PT Model HFS -P and HFS -PT Intelligent Photoelectric Smoke Sensors Engineering Specifications The smoke detector shall be a HFS -P or HFS -PT intelligent photoelectric smoke detector. The HFS -PT combines a photoelectric sensor with a 135 degree F (57.2 degree C) fixed temperature heat detector. The detector shall be UL listed per UL 268 specifically for use in open areas. The detector shall provide a trouble signal in the event that the sensor head is removed or improperly installed. The detector shall be capable of local testing via magnet, smoke entry, or direct heat method (HFS -PT only). Terminal connections shall be of the strip and clamp method suitable for 12 -18AWG wiring. Detector Connection to Panel SILENT This document is not intended to be used for installation purposes. We try to keep our product MADE IN AMERICA information up -to -date and accurate. We cannot cover all specific applications or anticipate all 13 i, KNIGHT requirements. All specifications are subject to change without notice. For more information, P/N 350140 Rev A contact Silent Knight 12 Clintonville Road, Northford, CT 06472 -1610 © 2010 Honeywell International Inc. by Honeywell Phone: (800) 328 -0103 or (203) 484 -7161, Fax: (203) 484 -7118. www.silentknight.com 3 ®R SILENT KNIGHT by Honeywell HFS -T IntelliKnight Plug -in Temperature Sensor with Plug -in Detector Base The HFS -T is an Intelligent sensor with a plug -in detector base that utilizes a state -of -art thermistor sensing circuit for fast response. This addressable thermal sensor is for use with Silent Knight Model 5600 IntelliKnight Fire Alarm Control Panel (FACP). Heat sensors are an essential component in virtually any Silent Knight installation. The IntelliKnight 5600 panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. For more information about the IntelliKnight Model 5600 system, or to locate your nearest source, please call 800 - 328 -0103. Description Model HFS -T is a fixed temperature sensor with 135 °F (57 °C) fixed temperature alarm. The sensor transmits an analog representation of temperature over a communication line to the control panel. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches. This detector is intended for use with model 5600 Intelligent system. Features • Sleek, low- profile design • Rotary address switches for fast installation • Innovative thermistor sensing circuit • Superior EMI resistance for reliability • Variety of mounting options to meet any application • Plug -in mounting provides ease of installation • Tamper -proof feature available on mounting bases • Plug -In base included • ETL and UL Listed Mounting Information: 4" (102 mm) square box with or without plaster ring; Minimum Depth — 1.5 inches (38 mm) 4" Octagon Box; Minimum Depth — 1.5 inches (38 mm) 3'/" Octagon Box; Minimum Depth — 1.5 inches (38 mm) Single Gang Box; Minimum Depth — 1.5 inches (38 mm) HFS -T Specifications Physical Height: 2.0" (51 mm) Diameter: 6.1" (155 mm) Shipping Weight: 4.8 oz (137 g) Electrical Operating Voltage: 15 to 32 Volts DC Peak Standby Current: 300pA @ 24 VDC LED Current: 6.5 mA@ 24 VDC Environmental Operating Temperature HFS -T: -4° — 100 °F (20 °C— 38 °C) Humidity: 10% — 93% noncondensing Thermal Ratings HFS -T: Fixed temperature setpoint 135 °F (57 °C) Compatibility The HFS -T, Honeywell Fire Systems sensor, is compatible with the model 5600 Intelligent fire control panel. You cannot use Hochiki or SK device type protocols on the 5600 SLC loop. Mode HFS -T Temperature Sensor with Plug -in Detector Base Engineering Specifications The heat detector shall be a HFS -T intelligent fixed temperature heat detector. The detector shall be UL listed per UL 521. The detector shall provide a trouble signal in the event that the sensor head is removed or improperly installed. The detector shall be capable of local testing via direct heat method. Terminal connections shall be of the strip and clamp method suitable for 12 -18AWG wiring. Heat Connection to Panel SILENT This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, Fax: (203)484 -7118. www.silentknight.com MADE IN AMERICA FORM# 350141 Rev A © 2010 Honeywell International Inc.