HomeMy WebLinkAboutA10-0055 Spec Sheetstqca
Fire &
Security
SimplemGrinnell
Fire Alarm
Product Data Submittal for:
Lodge @Vail
Lodge Tower -Suite 777
200 Vail Road
Vail, CO 81657
Prepared for:
J. Krueger & Co.
P.O. Box 630
SIMPLEXGRINNELL
6240 Smith Road
Denver, Colorado 80216
www.simplex.grinnell.com
Tele: (303) 355 -0500
Fax: (303) 355 -0615
Edwards, CO 81632
SimpfemGrinnell
6240 Smith Road
Denver, Colorado 80401
Sales: (303) 355 -0500
Service: (303) 355 -0500
Fax: (303) 355 -0615
PROJECT: Lodge Tower - Suite 777
PREPARED FOR: J. Krueger & Co.
TYPE: DESCRIPTION:
4098 -9714 PHOTO SENSOR
4098 -9794 SENSOR BASE W /SOUNDER
4902 -9717 SPEAKER WHITE TRUEALERT
f 3, S'l M P I ex
UL, ULC, CSFM Listed; FM Approved;
MEA (NYC) Acceptance*
Photoelectric, Ionization, and Heat Sensors
R "MR1 M_
Modular TrueAlarm sensor base with built -in
electronic alarm sounder:
Piezoelectric sounder provides high output (88 dBA)
with low current requirements (20 mA)
For use with interchangeable TrueAlarm sensors;
photoelectric, heat, or ionization (ordered separately)
Sounder operation details:
• Powered from 24 VDC or from a compatible
Notification Appliance Circuit (NAC)
• Synchronized via communications or by the NAC, if
NAC powered"
• Sounder can be manually activated from the control panel
• Sensor and sounder operation is listed to UL Standard 268
• Sounder operation is also listed to UL Standard 464
as an audible notification appliance
TrueAlarm analog sensing operation:
• Analog sensor information is digitally communicated
to the control panel via IDNetTM or MAPNET II
two -wire communications
• Sensor information is processed by the control panel
to determine sensor status
For use with the following Simplex products:
4010 and 4100U Series control panels; and 4008
Series control panels with reduced feature set (refer to
data sheet 54008 -0001 for details)
4020, 4100, and 4120 Series control panels, Universal
Transponders and 2120 TrueAlarm CDTs equipped
for MAPNET II operation
General features:
• Louvered smoke sensor design enhances smoke
capture by directing flow to chamber; entrance areas
are minimally visible when ceiling mounted
• Designed for EMI compatibility
• Magnetic test feature is provided
• Optional accessories include remote LED alarm
indicator and output relays
Additional base reference:
• For standard bases, refer to data sheet 54098 -0019
• For isolator bases, refer to data sheet 54098 -0025
• For photo /heat sensors, refer to data sheet 54098 -0024
(single address) and 54098 -0033 (dual address)
* This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section
13144.1 of the California Health and Safety Code. See CSFM Listings 7300 - 0026:217 and
7271 - 0026:231 for allowable values and /or conditions concerning material presented in this
document. It is subject to re- examination, revision, and possible cancellation. Accepted for use —
City of New York Department of Buildings — MEA35 -93E. Additional listings may be applicable,
contact your local Simplex product supplier for the latest status. Listings and approvals under
Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster.
** Total quantity of sounder bases available for coding on the same communications channel may vary
with panel application and availability of NAC power. Refer to specific control panel requirements.
t TrueAlarm analog sensors are protected by one or more of the following U.S. Patents: 5,155,468;
5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573. MAPNET II and
IDNet addressable communications designs are protected by U.S. Patent No. 4,796,025.
TrueAlarm
Analog Sensing
Sounder Base 4098 -9794 for use with TrueAlarm
TrueAlarm Photoelectric Sensor Mounted in
Sounder Base 4098 -9794
TrueAlarm Analog Sensing Description
Sounder bases combine an audible notification appliance
and a TrueAlarm analog sensor to provide:
Digital Communication of Analog Sensing.
Sensors provide an analog measurement that is digitally
communicated to the control panel where it is analyzed
and an average value is determined and stored. An alarm
or other abnormal condition is determined by comparing
the sensor's present value against its average value.
Intelligent Data Evaluation. Monitoring each sensor's
average value provides a software filtering averaging
process that compensates for environmental factors (dust,
dirt, etc.) and component aging, providing an accurate
reference for evaluating new activity. The result is a
significant reduction in the probability of false or
nuisance alarms caused by shifts in sensitivity, either up
or down.
Control Panel Selection. Peak activity per sensor is
stored to assist in evaluating specific locations. The alarm
set point for each TrueAlarm sensor is determined at the
control panel, selectable as more or less sensitive as the
individual application requires.
Timed /Multi -Stage Selection. Alarm set points can be
programmed for timed automatic sensitivity selection
(such as more sensitive at night, less sensitive during
day). Control panel programming can also provide
multi -stage operation per sensor. For example, a 0.2%
level may cause a warning to prompt investigation while a
2.5% level may initiate an alarm.
Sensor Alarm and Trouble LED Indication. Each
sensor base's LED pulses to indicate communications
with the panel. If the control panel determines that a
sensor is in alarm, or that it is dirty or has some other type
of trouble, the details are annunciated at the control panel
and that sensor base's LED will be turned on steadily.
During a system alarm, the control panel will control the
LEDs such that an LED indicating a trouble will return to
pulsing to help identify the alarmed sensors.
S4098- 0028 -5 8/2008
Additional Sounder Base Features
Base mounted address selection allows the address
to remain with its programmed location when the sensor
is removed for service or type change. Access is from the
front under the removable sensor.
Automatic sensor type identification provides
default sensitivity when substituting sensor types.
Different sensor types can be easily interchanged to meet
specific location requirements. This feature also allows
intentional sensor substitution during building
construction. When conditions are temporarily dusty,
instead of covering the smoke sensors (causing them to be
disabled), heat sensors may be installed without
reprogramming the control panel.
Integral red LED indicates power -on by pulsing, or
alarm or trouble when steady on. The exact status is
annunciated at the fire alarm control panel.
Fire alarm control panel provides:
• Peak value logging allowing accurate analysis of each
sensor for individual sensitivity selection
• Sensitivity monitoring satisfying NFPA 72
sensitivity testing requirements; automatic individual
sensor calibration check verifies sensor integrity
• Automatic environmental compensation, multi -stage
alarm operation, and display of sensitivity directly in
percent per foot
• Ability to display and print detailed sensor
information in plain English language
4098 -9822, LED Annunciation Relay activates when
base LED is on steady, indicating a local alarm or trouble.
Contacts are DPDT, rated 2 A @ 30 VDC; 1/2 A @
120 VAC for transient suppressed loads (requires external
24 VDC coil power).
2098 -9808, Remote red LED Alarm Indicator mounts on
a single gang box to provide status indications where the
sensor location may not be readily visible.
ALARM
0
G Simplex
2098 -9808 Remote LED Alarm Indicator
Mounting Reference
Electrical Box Requirements: (boxes are by others)
Without relay 4" octagonal or 4 square, 1 -1/2" deep; single gang,
2" deep
With relay 4" octagonal or 4 square, 1 -1/2" deep, with 1 -1/2"
extension ring
4" (102 mm) Square Box 4" (102 mm) Octagonal Box
Surface mount reference
C 1 -1/2" (38 mm)
nimum box depth
Flush mount reference, mount even with final
surface, or with up to 1/4" (6.4 mm) maximum recess
-
6 -3/8" Dia.
-- - - - - - - - - - - - - - - - - - - - - - - - - - ,
Optional 4098 -9822 Relay
x 1/4" thick
(Mounts in base electrical box
Note: Single gang
; and requires additional
adapter plate (RACO
volume, see notes below)
No. 787 or equal) is
required when using 4
(29 mm)
square box (by others)
Relay size:
t
2 -1/2" X 1 -1/2" X 1"
no
;(64mmX38mmX
25.4 mm), 3.75 cubic inches
6 -3/8" Dia.
x 1/4" thick
4098 -9832 Adapter Plate, re uired for mounting
to surface mounted boxes (mounts inverted)
L 6- 7/16" (164 mm) -�
1 -1/8"
(29 mm)
t
LED status Sound output louvers
indicator extend from front to side
(Photoelectric sensor shown for reference)
NOTES:
1. Review actual wire size, wire count, box type, and whether
4098 -9822 relay is used before determining box size.
2. Mounting to flush mounted box also fits single gang handy box,
2 -1/8" (51 mm) deep if wiring allows. (Not applicable if 4098 -9822
relay is used.)
3. For surface mounted boxes, use 4 square box with single gang
adapter plate (RACO No. 787 or equal, by others) or 4 octagonal
box, both re uire 4098 -9832 Adapter Plate.
4. When 4098 -9822 relay is used, mount relay in electrical box and use
1 -1/2" extension ring (by others) on 4 square or octagonal box of
1 -1/2" or 2 -1/8" depth as required.
5. Refer to Installation Instructions 574 -707 for additional information.
S4098- 0028 -5 8/2008
TrueAlarm Analog Sensor Features
Sealed against rear air flow entry
Electronics are EMI /RFI shielded
Heat sensors:
• Selectable rate compensated, fixed temperature
sensing with or without rate -of -rise operation
• Rated spacing distance between sensors:
Fixed Temp.
UL & ULC
FM Spacing, Either Fixed
Setting
Spacing
Temperature Setting
135° F
60 ft x 60 ft
20 ft x 20 ft (6.1 m) for fixed
(57.2° C)
(18.3 m)
temperature only; RTI = Quick
50 ft x 50 ft (15.2 m) for fixed
155° F
40 ft x 40 ft
temperature with either rate -of -rise
(68° C)
(12.2 m)
selection; RTI = Ultra Fast
Smoke Sensors:
• Photoelectric or ionization technology sensing
• 360° smoke entry for optimum response
• Built -in insect screens
4098 -9733 Heat Sensor
TrueAlarm heat sensors are self - restoring and provide rate
compensated, fixed temperature sensing, selectable with
or without rate -of -rise temperature sensing. Due to its
small thermal mass, the sensor accurately and quickly
measures the local temperature for analysis at the fire
alarm control panel.
Rate -of -rise temperature detection is selectable at the
control panel for either 15' F (8.3' C) or 20° F (11.1 ° C)
per minute. Fixed temperature sensing is independent of
rate -of -rise sensing and programmable to operate at
135° F (57.2° C) or 155° F (68° Q. In a slow developing
fire, the temperature may not increase rapidly enough to
operate the rate -of -rise feature. However, an alarm will be
initiated when the temperature reaches its rated fixed
temperature setting.
TrueAlarm heat sensors can be programmed as a utility
device to monitor for temperature extremes in the range
from 32° F to 155° F (0° C to 68° Q. This feature can
provide freeze warnings or alert to HVAC system
problems. Refer to specific panels for availability.
6- 7/16" (164 mm)
4098 -9714 Photoelectric Sensor
TrueAlarm photoelectric sensors use a stable, pulsed
infrared LED light source and a silicon photodiode
receiver to provide consistent and accurate low power
smoke sensing. Seven levels of sensitivity are available
for each individual sensor, ranging from 0.2% to 3.7% per
foot of smoke obscuration. Sensitivity is selected and
monitored at the fire alarm control panel.
The sensor head design provides 360° smoke entry for
optimum smoke response. Due to its photoelectric
operation, air velocity is not normally a factor, except for
impact on area smoke flow.
6 -7/16" (164 mm)
4098 -9714 Photoelectric Sensor with Sounder Base
4098 -9717 Ionization Sensor
TrueAlarm ionization sensors use a single radioactive
source with an outer sampling ionization chamber and an
inner reference ionization chamber to provide stable
operation under fluctuations in environmental conditions
such as temperature and humidity. Smoke and invisible
combustion gases can freely penetrate the outer chamber.
With both chambers ionized by a small radioactive source
[Am 241 (Americium)], a very small current flows in the
circuit. The presence of particles of combustion will cause
a change in the voltage ratio between chambers. This
difference is measured by the electronics in the sensor
base and digitally transmitted back to the control panel for
processing.
Three levels of sensitivity are available for each sensor:
0.5, 0.9, and 1.3% per foot of smoke obscuration.
7/16" (164 mm)
4098 -9717 Ionization Sensor with Sounder Base
4098 -9733 Heat Sensor with 4098 -9794 Sounder Base
WARNING: In most fires, hazardous levels of smoke
and toxic gas can build up before a heat detection
device would initiate an alarm. In cases where Life
Safety is a factor, the use of smoke detection is highly
recommended.
(Application Reference
Sensor locations should be determined after careful
consideration of the physical layout and contents of the
area to be protected. Refer to NFPA 72, the National Fire
Alarm Code"'. On smooth ceilings, smoke sensor spacing
of 30 ft (9.1 m) may be used as a guide. For detailed
application information, refer to 4098 Detectors, Sensors,
and Bases Application Manual, Part Number 574 -709.
S4098- 0028 -5 8/2008
11 liq
• • • • • •
TrueAlarm Sounder Base*
Model Description Compatibility Mounting Requirements
Sounder Base with connections Sensors: 4098 -9714, -9717, or -9733
4098 -9794 for Remote LED Alarm Indicator Refer to page 2, mounting reference
or Unsupervised Relay Options: 2098 -9808 remote LED alarm
indicator or 4098 -9822 rela
TrueAlarm Sensors (ordered separately)
Model Description Mounting Requirements
4098 -9714 Photoelectric Smoke Sensor
4098 -9717 Ionization Smoke Sensor Refer to page 2, mounting reference
4098 -9733 Heat Sensor
Sounder Base Accessories (ordered separately if required)
MAPNET II or IDNet, auto - select, 24 -40 VDC w /data, 400 µA typical,
1 address per base, supplied by control panel
Model Description
Mounting Requirements
4098 -9832 Adapter Plate, required for surface mounted 4" electrical boxes
Refer to page 2, mounting reference
2098 -9808
UL Listed Temperature Range
Remote red LED Alarm Indicator on single gang
Single gang box, 1 -1/2" minimum depth
32° F to 122° F (0° C to 50° C)
Choose one if
required
stainless steel plate
10 to 95% RH
4098 -9822
Relay, tracks base LED status (unsupervised, to be
Mounts in base electrical box (requires 1 -1/2"
Housing Color
Frost White
mounted only in base electrical box)
extension on 4" square or octagonal box)
* Refer to data sheet S4098 -0019 for other compatible bases. Refer to Installation Instructions 574 -707 and Application Manual 574 -709 for
additional information.
•- •
13 mA from separate 24 VDC supply
General Operating Specifications
Communications and Sensor Supervisory Power
MAPNET II or IDNet, auto - select, 24 -40 VDC w /data, 400 µA typical,
1 address per base, supplied by control panel
Communications and Sounder Power Connections
Screw terminals for in /out wiring, 18 to 14 AWG (0.82 mm to 2.08 mm
Remote LED Alarm Indicator Current
LED Connections
1 mA typical supplied from communications, no impact to alarm current
Color coded wire leads, 18 AWG (0.82 mm )
UL Listed Temperature Range
32° F to 100° F (0° C to 38° C)
Operating With 4098 -9717 or 4098 -9733
Temperature Range With 4098 -9714
32° F to 122° F (0° C to 50° C)
15° F to 122° F ( -9° C to 50° C)
Humidity Range
10 to 95% RH
Smoke Sensor 4098 -9714, Photoelectric Sensor
Ambient Ratings 4098 -9717, Ionization Sensor
Air velocity is 0 -2000 ft /min (0 -610 m /min)
Air velocity is 0 -200 ft /min (0 -61 m /min); Altitude is up to 8000 ft (2.4 km
Housing Color
Frost White
Sounder Operation
Sounder Voltage 18 to 32 VDC from steady external source or from NAC
Alarm Current (Sounder On)
20 mA @ 24 VDC, 24 mA maximum @ 32 VDC
88 dBA minimum @ 10 ft (3 m) per UL Standard 464, Audible Signaling
Sounder Output
Appliances and UL Standard 268, Smoke Detectors for Fire Protective
Signaling Systems
Sounder Power Supervision Supervised
Select for continuous 24 VDC power, loss of power is communicated to panel
(Selectable) Unsupervised
Select when connected to NAC for sounder power, NAC provides supervision
NAC Powered Operation
When in alarm, will sound when NAC is in alarm, allowing synchronized
pattern (Temporal or March Time, etc.) controlled by the NAC
4098 -9822 Unsupervised Relay Option
Externally Supplied Relay Voltage
18 -32 VDC, steady source recommended (wires to remote LED leads)
Alarm Current
13 mA from separate 24 VDC supply
Contact Ratings, DPDT contacts for
Power limited rating: 2 A @ 30 VDC
Non -power limited rating: 1/2 A @ 120 VAC
resistive /suppressed loads
Relay Operation
Tracks base LED status, relay is on with trouble or alarm at the base
Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex, the Simplex logo, TrueAlarm, IDNet, and MAPNET II are trademarks of
Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association
(NFPA).
Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4098- 0028 -5 8/2008
93.Simplex
www. tycosafetyproducts- usa -wm. com
c 2008 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.
f
UL, ULC, CSFM Listed; FM Approved;
MEA (NYC) Acceptance*
Multi - Application Peripherals
Audible Notification Appliances
Speakers, 25 or 70.7 VRMS, Wall or Ceiling Mount
Fire alarm speakers with models for ceiling or
wall mount:
• Four inch cone (102 mm) provides high quality tone and
voice reproduction
• Multi - tapped design provides output power of 1/4, 1/2,
1, or 2 W with either 25 or 70.7 VRMS input
• In/out wiring terminals for 18 AWG to 12 AWG
• Mounts to 4" square outlet box, 1 -1 /2" deep with 1 -1 /2"
deep box extension
• Capacitor input for connection to supervised notification
appliance circuits
• Rugged, high impact, flame retardant thermoplastic
housings
• UL listed to Standard 1480
• ULC listed to Standard 5541, refer to page 4 for
required minimum wattage tap per housing type
Rectangular housing models feature:
• Appearance that complements TrueAlert strobes and
speaker /strobes
• Red or white housings with "FIRE" lettering for surface
or semi -flush wall mount
• Optional matching adapter skirts for covering surface
mounted electrical boxes*
• Optional red wire guard
Round housing models feature:
• Off -white color (no lettering) for flush mount on ceiling
or wall
• Compatible with optional the bridge 2905 -9946
Simplex 4902 Series speakers provide high quality sound
for emergency fire alarm use as well as for background
music. The moisture - repellent speaker is designed for
smooth frequency response with minimal distortion.
The multi - tapped speaker transformer accommodates
either 25 or 70.7 VRMS and provides an output of from
1/4 to 2 W to provide flexibility for satisfying the
requirements of the installed conditions.
Rectangular housing models are for surface or semi -flush
wall mount applications. Round housing models are
typically for ceiling applications but can be wall mounted
if desired. The rectangular housing speakers are designed
to compliment the TrueAlert family of strobes and
speaker /strobes, providing conventional, non - addressable
speaker operation.
* Refer to page 2 for guard and adapter skirt listing. This product has been approved by the
California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health
and Safety Code. See CSFM Listing 7320 - 0026:242 for allowable values and /or conditions
concerning material presented in this document. It is subject to re- examination, revision,
and possible cancellation. Additional listings may be applicable; contact your local Simplex
product supplier for the latest status. Listings and approvals under Simplex Time Recorder
Co. are the property of Tyco Safety Products Westminster.
FIRE
Rectangular Wall Mount Speakers are Available
as Red with White "Fire" Lettering and
White with Red "Fire" Lettering
Round Speakers are Available in Off -White (no lettering)
Specifications
Dimensions, Rectangular Wall Mount Housings
Housing Dimensions 5-1/8" H x 5" W x 1-1/2" D
(130 mm x 127 mm x 38 mm)
Depth into Box 2 -3/4" (70 mm)
Dimensions, Round Housings
7-1/2 " Diameter, 1/2" D
Housing Dimensions (191 mm x 13 mm)
Depth into Box 2 -3/4" (70 mm)
General Specifications
Input Voltage
25 or 70.7 VRMS
Power Taps
1/4 1/2 1, and 2 W
Input Terminal Ratings
18 to 12 AWG 2
(0.82 mm to 3.31 mm )
Fire Alarm
Frequency
Response General
Signaling
400 to 4000 Hz
125 to 12 kHz
Sound Output
See information on page 4
Temperature Range
32 to 100° F (0 to 38° C)
Humidity Range
10% to 95% RH from 32 to
122° F (0 to 50° C)
S4902- 0003 -6 9/2009
• • Le I
Speakers
Model* Description Dimensions
4902 -9716 (CA) Rectangular housing, wall mount Red with white "FIRE" lettering 5-1/8" H x 5" W x 1 -1 /2" D
4902 -9717 (CA) speaker White with red "FIRE" lettering (130 mm x 127 mm x 38 mm)
4902 -9721 (CA) Round housing speaker, ceiling or wall Off -white (no lettering) 7-1/2" Diameter x 1/2" D
mount (191 mm x 13 mm)
* ULC listed model are designated with a CA suffix (4902- 9716CA). Refer to Installation Instructions 574 -765 for non - suffix model
numbers and to Installation Instructions 579 -324 for CA suffix model numbers.
Mounting Adapters
Model
Description
Dimensions
4905 -9941
Red Use to cover surface mounted
5 -3/8" H x 5 -1/4" W x 3- 3/16" D
Surface mount adapter skirt; 1-1/2" deep box with 1-1/2"
(136 mm x 133 mm x 81 mm)
(not ULC listed) deep extension external to
Total surface depth with
4905 -9942
White wall (see diagram on page 3)
speaker = 4 -5/8" (117 mm)
2905 -9946
Tile bridge for 4902 -9721 Speaker
See diagram on page 3
4905 -9931
Adapter Plate, red, for mounting to 2975 -9145 box (typically for retrofit,
8- 5/16" x 5 - 3/4 " x 0.060" Thick
may be mounted vertical or horizontal)
(211 mm x 146 mm x 1.5 mm)
2975 -9145
Red mounting box, requires Adapter Plate 4905 -9931
7 -7/8" x 5-1/8" x 2 -3/4" D
(200 mm x 130 mm x 70 mm)
Covers and Guard
Model Description Dimensions
4905 -9988 Red speaker cover with white "FIRE" lettering Interchangeable with 5-1/8" H x 5" W x 1-1/2" D
4905 -9989 White speaker cover with red "FIRE" lettering TrueAlert horns (130 mm x 127 mm x 38 mm)
Red wire guard with mounting plate; compatible with semi -flush or surface 6 -1 /16" H x 6 -1 /16" W x 3 -1 /8" D
4905 -9999 mounted boxes; for use with 4" square electrical box mounting hole (154 mm x 154 mm x 79 mm)
patterns only (UL listed by Space Age Electronics Inc.)
1111111liq 1:9 L:9 V] I Oil
• • •
Mounting requires a 4" (102 mm) square
box, 1-1/2" (38 mm) deep, with a 4" box
extension, 1-1/2" deep, by others o
J
J
J
Speaker assembly J
J
0
\Wiring input terminals and speaker tap
O O O selection are accessible from rear of
1 � speaker housing
J
Transparent speaker
housing
Removable cover
(tool required)
FED) [E
2 S4902- 0003 -6 9/2009
Round Speaker Installation Reference (typically ceiling mount, can be wall mounted)
Wiring input terminals and speaker i
tap selection are accessible from
rear of speaker housing
4" square, 1-1/2" deep box
with 1-1/2" extension (by others)
0
000009 1��
AVON monow
Front View
2905 -9946 Tile Bridge Dimensions
0.024" thick sheet
3 -3/4" (95 mm) square metal, folded with
cutout, centered on plate 1/2" lip each side
0
1/2"
(13 mm) 0 0 13 -3/8"
(340 mm)
1/4" diameter (6 mm) 0
holes, 4 places
6- 11/16"
(170 mm)
23-11/16" (602 mm)
Surface Mounted Speaker Reference (Adapter Skirts are Not ULC listed
4" (102 mm) square box, 1 -1/2" (38 mm) deep
with conduit shown for reference
4" (102 mm) square box
extension, 1-1/2" (38 mm) deep
Optional 4905 -9999 Wire Guard
Speaker
assembly
Surface mount adapter skirt, 3- 3/16" deep:
4905 -9941, Red; 4905 -9942, White
Conduit knockouts are
provided on all four sides
Wall surface
3 S4902- 0003 -6 9/2009
• • • I 111 111! •• • in
Sound Output Ratings @ 10 ft ( -3 m) per UL 1480 Reverberant Chamber Testing
Model
Type
Input Voltage
Selected Tap
1/4 W
1/2 W
1 W
2 W
4902 -9716
4902 -9717
Rectangular Housing
25 VRMS
80 dBA
83 dBA
85 dBA
88 dBA
70.7 VRMS
79 dBA
82 dBA
85 dBA
88 dBA
4902 -9721
Round Housing
25 or 70.7 VRMS
79 dBA
82 dBA
85 dBA
88 dBA
Sound Output Ratings @ 3 m ( -10 ft) per ULC S541 Anechoic Chamber Testing
Selected Tap
Model Type Input Voltage 1/4 W 1/2 W 1 W* 2 W*
(see note) (see note)
4902- 9716CA Rectangular Housing* 25 VRMS or 70.7 VRMS 77 dBA 80 dBA 83 dBA 86 dBA
4902- 9717CA
4902 -9721 CA Round Housing* 25 VRMS or 70.7 VRMS 79 dBA 82 dBA 85 dBA 89 dBA
* NOTE: ULC Fire Alarm applications require use of 1 W or 2 W tap for Round Housing speakers; and 2 W tap for Rectangular
Housing speakers.
Speaker Polar Dispersion Reference (per ULC S541 Anechoic Chamber Testing)
Attenuation Angle
-3 dB 30° off -axis
-6 dB 1 55 off -axis
4905 -9931 Adapter Plate Installation Reference
4905 -9931 Ada
4905 -9999 Optic
Wire Gu
(shown here
reference only,
be used on of
mounting optic
2975 -9145 Box
bly
4905 -9931 Adapter Plate
Tyco is a registered trademark of Tyco International Services GnMH and is used under license. Simplex, the Simplex logo, and TrueAlert are trademarks of Tyco International Ltd.
and its affiliates and are used under license.
93.Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4902- 0003 -6 9/2009
www. tycosafetyproducts- usa -wm. com
C 1 2009 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.