HomeMy WebLinkAboutA10-0055 Spec Sheetstqca Fire & Security SimplemGrinnell Fire Alarm Product Data Submittal for: Lodge @Vail Lodge Tower -Suite 777 200 Vail Road Vail, CO 81657 Prepared for: J. Krueger & Co. P.O. Box 630 SIMPLEXGRINNELL 6240 Smith Road Denver, Colorado 80216 www.simplex.grinnell.com Tele: (303) 355 -0500 Fax: (303) 355 -0615 Edwards, CO 81632 SimpfemGrinnell 6240 Smith Road Denver, Colorado 80401 Sales: (303) 355 -0500 Service: (303) 355 -0500 Fax: (303) 355 -0615 PROJECT: Lodge Tower - Suite 777 PREPARED FOR: J. Krueger & Co. TYPE: DESCRIPTION: 4098 -9714 PHOTO SENSOR 4098 -9794 SENSOR BASE W /SOUNDER 4902 -9717 SPEAKER WHITE TRUEALERT f 3, S'l M P I ex UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Photoelectric, Ionization, and Heat Sensors R "MR1 M_ Modular TrueAlarm sensor base with built -in electronic alarm sounder: Piezoelectric sounder provides high output (88 dBA) with low current requirements (20 mA) For use with interchangeable TrueAlarm sensors; photoelectric, heat, or ionization (ordered separately) Sounder operation details: • Powered from 24 VDC or from a compatible Notification Appliance Circuit (NAC) • Synchronized via communications or by the NAC, if NAC powered" • Sounder can be manually activated from the control panel • Sensor and sounder operation is listed to UL Standard 268 • Sounder operation is also listed to UL Standard 464 as an audible notification appliance TrueAlarm analog sensing operation: • Analog sensor information is digitally communicated to the control panel via IDNetTM or MAPNET II two -wire communications • Sensor information is processed by the control panel to determine sensor status For use with the following Simplex products: 4010 and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet 54008 -0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders and 2120 TrueAlarm CDTs equipped for MAPNET II operation General features: • Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted • Designed for EMI compatibility • Magnetic test feature is provided • Optional accessories include remote LED alarm indicator and output relays Additional base reference: • For standard bases, refer to data sheet 54098 -0019 • For isolator bases, refer to data sheet 54098 -0025 • For photo /heat sensors, refer to data sheet 54098 -0024 (single address) and 54098 -0033 (dual address) * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7300 - 0026:217 and 7271 - 0026:231 for allowable values and /or conditions concerning material presented in this document. It is subject to re- examination, revision, and possible cancellation. Accepted for use — City of New York Department of Buildings — MEA35 -93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Total quantity of sounder bases available for coding on the same communications channel may vary with panel application and availability of NAC power. Refer to specific control panel requirements. t TrueAlarm analog sensors are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573. MAPNET II and IDNet addressable communications designs are protected by U.S. Patent No. 4,796,025. TrueAlarm Analog Sensing Sounder Base 4098 -9794 for use with TrueAlarm TrueAlarm Photoelectric Sensor Mounted in Sounder Base 4098 -9794 TrueAlarm Analog Sensing Description Sounder bases combine an audible notification appliance and a TrueAlarm analog sensor to provide: Digital Communication of Analog Sensing. Sensors provide an analog measurement that is digitally communicated to the control panel where it is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value. Intelligent Data Evaluation. Monitoring each sensor's average value provides a software filtering averaging process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the control panel, selectable as more or less sensitive as the individual application requires. Timed /Multi -Stage Selection. Alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi -stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. S4098- 0028 -5 8/2008 Additional Sounder Base Features Base mounted address selection allows the address to remain with its programmed location when the sensor is removed for service or type change. Access is from the front under the removable sensor. Automatic sensor type identification provides default sensitivity when substituting sensor types. Different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Integral red LED indicates power -on by pulsing, or alarm or trouble when steady on. The exact status is annunciated at the fire alarm control panel. Fire alarm control panel provides: • Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection • Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity • Automatic environmental compensation, multi -stage alarm operation, and display of sensitivity directly in percent per foot • Ability to display and print detailed sensor information in plain English language 4098 -9822, LED Annunciation Relay activates when base LED is on steady, indicating a local alarm or trouble. Contacts are DPDT, rated 2 A @ 30 VDC; 1/2 A @ 120 VAC for transient suppressed loads (requires external 24 VDC coil power). 2098 -9808, Remote red LED Alarm Indicator mounts on a single gang box to provide status indications where the sensor location may not be readily visible. ALARM 0 G Simplex 2098 -9808 Remote LED Alarm Indicator Mounting Reference Electrical Box Requirements: (boxes are by others) Without relay 4" octagonal or 4 square, 1 -1/2" deep; single gang, 2" deep With relay 4" octagonal or 4 square, 1 -1/2" deep, with 1 -1/2" extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference C 1 -1/2" (38 mm) nimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess - 6 -3/8" Dia. -- - - - - - - - - - - - - - - - - - - - - - - - - - , Optional 4098 -9822 Relay x 1/4" thick (Mounts in base electrical box Note: Single gang ; and requires additional adapter plate (RACO volume, see notes below) No. 787 or equal) is required when using 4 (29 mm) square box (by others) Relay size: t 2 -1/2" X 1 -1/2" X 1" no ;(64mmX38mmX 25.4 mm), 3.75 cubic inches 6 -3/8" Dia. x 1/4" thick 4098 -9832 Adapter Plate, re uired for mounting to surface mounted boxes (mounts inverted) L 6- 7/16" (164 mm) -� 1 -1/8" (29 mm) t LED status Sound output louvers indicator extend from front to side (Photoelectric sensor shown for reference) NOTES: 1. Review actual wire size, wire count, box type, and whether 4098 -9822 relay is used before determining box size. 2. Mounting to flush mounted box also fits single gang handy box, 2 -1/8" (51 mm) deep if wiring allows. (Not applicable if 4098 -9822 relay is used.) 3. For surface mounted boxes, use 4 square box with single gang adapter plate (RACO No. 787 or equal, by others) or 4 octagonal box, both re uire 4098 -9832 Adapter Plate. 4. When 4098 -9822 relay is used, mount relay in electrical box and use 1 -1/2" extension ring (by others) on 4 square or octagonal box of 1 -1/2" or 2 -1/8" depth as required. 5. Refer to Installation Instructions 574 -707 for additional information. S4098- 0028 -5 8/2008 TrueAlarm Analog Sensor Features Sealed against rear air flow entry Electronics are EMI /RFI shielded Heat sensors: • Selectable rate compensated, fixed temperature sensing with or without rate -of -rise operation • Rated spacing distance between sensors: Fixed Temp. UL & ULC FM Spacing, Either Fixed Setting Spacing Temperature Setting 135° F 60 ft x 60 ft 20 ft x 20 ft (6.1 m) for fixed (57.2° C) (18.3 m) temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed 155° F 40 ft x 40 ft temperature with either rate -of -rise (68° C) (12.2 m) selection; RTI = Ultra Fast Smoke Sensors: • Photoelectric or ionization technology sensing • 360° smoke entry for optimum response • Built -in insect screens 4098 -9733 Heat Sensor TrueAlarm heat sensors are self - restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate -of -rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate -of -rise temperature detection is selectable at the control panel for either 15' F (8.3' C) or 20° F (11.1 ° C) per minute. Fixed temperature sensing is independent of rate -of -rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° Q. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate -of -rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 6- 7/16" (164 mm) 4098 -9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. The sensor head design provides 360° smoke entry for optimum smoke response. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 6 -7/16" (164 mm) 4098 -9714 Photoelectric Sensor with Sounder Base 4098 -9717 Ionization Sensor TrueAlarm ionization sensors use a single radioactive source with an outer sampling ionization chamber and an inner reference ionization chamber to provide stable operation under fluctuations in environmental conditions such as temperature and humidity. Smoke and invisible combustion gases can freely penetrate the outer chamber. With both chambers ionized by a small radioactive source [Am 241 (Americium)], a very small current flows in the circuit. The presence of particles of combustion will cause a change in the voltage ratio between chambers. This difference is measured by the electronics in the sensor base and digitally transmitted back to the control panel for processing. Three levels of sensitivity are available for each sensor: 0.5, 0.9, and 1.3% per foot of smoke obscuration. 7/16" (164 mm) 4098 -9717 Ionization Sensor with Sounder Base 4098 -9733 Heat Sensor with 4098 -9794 Sounder Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. (Application Reference Sensor locations should be determined after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code"'. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide. For detailed application information, refer to 4098 Detectors, Sensors, and Bases Application Manual, Part Number 574 -709. S4098- 0028 -5 8/2008 11 liq • • • • • • TrueAlarm Sounder Base* Model Description Compatibility Mounting Requirements Sounder Base with connections Sensors: 4098 -9714, -9717, or -9733 4098 -9794 for Remote LED Alarm Indicator Refer to page 2, mounting reference or Unsupervised Relay Options: 2098 -9808 remote LED alarm indicator or 4098 -9822 rela TrueAlarm Sensors (ordered separately) Model Description Mounting Requirements 4098 -9714 Photoelectric Smoke Sensor 4098 -9717 Ionization Smoke Sensor Refer to page 2, mounting reference 4098 -9733 Heat Sensor Sounder Base Accessories (ordered separately if required) MAPNET II or IDNet, auto - select, 24 -40 VDC w /data, 400 µA typical, 1 address per base, supplied by control panel Model Description Mounting Requirements 4098 -9832 Adapter Plate, required for surface mounted 4" electrical boxes Refer to page 2, mounting reference 2098 -9808 UL Listed Temperature Range Remote red LED Alarm Indicator on single gang Single gang box, 1 -1/2" minimum depth 32° F to 122° F (0° C to 50° C) Choose one if required stainless steel plate 10 to 95% RH 4098 -9822 Relay, tracks base LED status (unsupervised, to be Mounts in base electrical box (requires 1 -1/2" Housing Color Frost White mounted only in base electrical box) extension on 4" square or octagonal box) * Refer to data sheet S4098 -0019 for other compatible bases. Refer to Installation Instructions 574 -707 and Application Manual 574 -709 for additional information. •- • 13 mA from separate 24 VDC supply General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet, auto - select, 24 -40 VDC w /data, 400 µA typical, 1 address per base, supplied by control panel Communications and Sounder Power Connections Screw terminals for in /out wiring, 18 to 14 AWG (0.82 mm to 2.08 mm Remote LED Alarm Indicator Current LED Connections 1 mA typical supplied from communications, no impact to alarm current Color coded wire leads, 18 AWG (0.82 mm ) UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating With 4098 -9717 or 4098 -9733 Temperature Range With 4098 -9714 32° F to 122° F (0° C to 50° C) 15° F to 122° F ( -9° C to 50° C) Humidity Range 10 to 95% RH Smoke Sensor 4098 -9714, Photoelectric Sensor Ambient Ratings 4098 -9717, Ionization Sensor Air velocity is 0 -2000 ft /min (0 -610 m /min) Air velocity is 0 -200 ft /min (0 -61 m /min); Altitude is up to 8000 ft (2.4 km Housing Color Frost White Sounder Operation Sounder Voltage 18 to 32 VDC from steady external source or from NAC Alarm Current (Sounder On) 20 mA @ 24 VDC, 24 mA maximum @ 32 VDC 88 dBA minimum @ 10 ft (3 m) per UL Standard 464, Audible Signaling Sounder Output Appliances and UL Standard 268, Smoke Detectors for Fire Protective Signaling Systems Sounder Power Supervision Supervised Select for continuous 24 VDC power, loss of power is communicated to panel (Selectable) Unsupervised Select when connected to NAC for sounder power, NAC provides supervision NAC Powered Operation When in alarm, will sound when NAC is in alarm, allowing synchronized pattern (Temporal or March Time, etc.) controlled by the NAC 4098 -9822 Unsupervised Relay Option Externally Supplied Relay Voltage 18 -32 VDC, steady source recommended (wires to remote LED leads) Alarm Current 13 mA from separate 24 VDC supply Contact Ratings, DPDT contacts for Power limited rating: 2 A @ 30 VDC Non -power limited rating: 1/2 A @ 120 VAC resistive /suppressed loads Relay Operation Tracks base LED status, relay is on with trouble or alarm at the base Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex, the Simplex logo, TrueAlarm, IDNet, and MAPNET II are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4098- 0028 -5 8/2008 93.Simplex www. tycosafetyproducts- usa -wm. com c 2008 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. f UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Multi - Application Peripherals Audible Notification Appliances Speakers, 25 or 70.7 VRMS, Wall or Ceiling Mount Fire alarm speakers with models for ceiling or wall mount: • Four inch cone (102 mm) provides high quality tone and voice reproduction • Multi - tapped design provides output power of 1/4, 1/2, 1, or 2 W with either 25 or 70.7 VRMS input • In/out wiring terminals for 18 AWG to 12 AWG • Mounts to 4" square outlet box, 1 -1 /2" deep with 1 -1 /2" deep box extension • Capacitor input for connection to supervised notification appliance circuits • Rugged, high impact, flame retardant thermoplastic housings • UL listed to Standard 1480 • ULC listed to Standard 5541, refer to page 4 for required minimum wattage tap per housing type Rectangular housing models feature: • Appearance that complements TrueAlert strobes and speaker /strobes • Red or white housings with "FIRE" lettering for surface or semi -flush wall mount • Optional matching adapter skirts for covering surface mounted electrical boxes* • Optional red wire guard Round housing models feature: • Off -white color (no lettering) for flush mount on ceiling or wall • Compatible with optional the bridge 2905 -9946 Simplex 4902 Series speakers provide high quality sound for emergency fire alarm use as well as for background music. The moisture - repellent speaker is designed for smooth frequency response with minimal distortion. The multi - tapped speaker transformer accommodates either 25 or 70.7 VRMS and provides an output of from 1/4 to 2 W to provide flexibility for satisfying the requirements of the installed conditions. Rectangular housing models are for surface or semi -flush wall mount applications. Round housing models are typically for ceiling applications but can be wall mounted if desired. The rectangular housing speakers are designed to compliment the TrueAlert family of strobes and speaker /strobes, providing conventional, non - addressable speaker operation. * Refer to page 2 for guard and adapter skirt listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7320 - 0026:242 for allowable values and /or conditions concerning material presented in this document. It is subject to re- examination, revision, and possible cancellation. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. FIRE Rectangular Wall Mount Speakers are Available as Red with White "Fire" Lettering and White with Red "Fire" Lettering Round Speakers are Available in Off -White (no lettering) Specifications Dimensions, Rectangular Wall Mount Housings Housing Dimensions 5-1/8" H x 5" W x 1-1/2" D (130 mm x 127 mm x 38 mm) Depth into Box 2 -3/4" (70 mm) Dimensions, Round Housings 7-1/2 " Diameter, 1/2" D Housing Dimensions (191 mm x 13 mm) Depth into Box 2 -3/4" (70 mm) General Specifications Input Voltage 25 or 70.7 VRMS Power Taps 1/4 1/2 1, and 2 W Input Terminal Ratings 18 to 12 AWG 2 (0.82 mm to 3.31 mm ) Fire Alarm Frequency Response General Signaling 400 to 4000 Hz 125 to 12 kHz Sound Output See information on page 4 Temperature Range 32 to 100° F (0 to 38° C) Humidity Range 10% to 95% RH from 32 to 122° F (0 to 50° C) S4902- 0003 -6 9/2009 • • Le I Speakers Model* Description Dimensions 4902 -9716 (CA) Rectangular housing, wall mount Red with white "FIRE" lettering 5-1/8" H x 5" W x 1 -1 /2" D 4902 -9717 (CA) speaker White with red "FIRE" lettering (130 mm x 127 mm x 38 mm) 4902 -9721 (CA) Round housing speaker, ceiling or wall Off -white (no lettering) 7-1/2" Diameter x 1/2" D mount (191 mm x 13 mm) * ULC listed model are designated with a CA suffix (4902- 9716CA). Refer to Installation Instructions 574 -765 for non - suffix model numbers and to Installation Instructions 579 -324 for CA suffix model numbers. Mounting Adapters Model Description Dimensions 4905 -9941 Red Use to cover surface mounted 5 -3/8" H x 5 -1/4" W x 3- 3/16" D Surface mount adapter skirt; 1-1/2" deep box with 1-1/2" (136 mm x 133 mm x 81 mm) (not ULC listed) deep extension external to Total surface depth with 4905 -9942 White wall (see diagram on page 3) speaker = 4 -5/8" (117 mm) 2905 -9946 Tile bridge for 4902 -9721 Speaker See diagram on page 3 4905 -9931 Adapter Plate, red, for mounting to 2975 -9145 box (typically for retrofit, 8- 5/16" x 5 - 3/4 " x 0.060" Thick may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red mounting box, requires Adapter Plate 4905 -9931 7 -7/8" x 5-1/8" x 2 -3/4" D (200 mm x 130 mm x 70 mm) Covers and Guard Model Description Dimensions 4905 -9988 Red speaker cover with white "FIRE" lettering Interchangeable with 5-1/8" H x 5" W x 1-1/2" D 4905 -9989 White speaker cover with red "FIRE" lettering TrueAlert horns (130 mm x 127 mm x 38 mm) Red wire guard with mounting plate; compatible with semi -flush or surface 6 -1 /16" H x 6 -1 /16" W x 3 -1 /8" D 4905 -9999 mounted boxes; for use with 4" square electrical box mounting hole (154 mm x 154 mm x 79 mm) patterns only (UL listed by Space Age Electronics Inc.) 1111111liq 1:9 L:9 V] I Oil • • • Mounting requires a 4" (102 mm) square box, 1-1/2" (38 mm) deep, with a 4" box extension, 1-1/2" deep, by others o J J J Speaker assembly J J 0 \Wiring input terminals and speaker tap O O O selection are accessible from rear of 1 � speaker housing J Transparent speaker housing Removable cover (tool required) FED) [E 2 S4902- 0003 -6 9/2009 Round Speaker Installation Reference (typically ceiling mount, can be wall mounted) Wiring input terminals and speaker i tap selection are accessible from rear of speaker housing 4" square, 1-1/2" deep box with 1-1/2" extension (by others) 0 000009 1�� AVON monow Front View 2905 -9946 Tile Bridge Dimensions 0.024" thick sheet 3 -3/4" (95 mm) square metal, folded with cutout, centered on plate 1/2" lip each side 0 1/2" (13 mm) 0 0 13 -3/8" (340 mm) 1/4" diameter (6 mm) 0 holes, 4 places 6- 11/16" (170 mm) 23-11/16" (602 mm) Surface Mounted Speaker Reference (Adapter Skirts are Not ULC listed 4" (102 mm) square box, 1 -1/2" (38 mm) deep with conduit shown for reference 4" (102 mm) square box extension, 1-1/2" (38 mm) deep Optional 4905 -9999 Wire Guard Speaker assembly Surface mount adapter skirt, 3- 3/16" deep: 4905 -9941, Red; 4905 -9942, White Conduit knockouts are provided on all four sides Wall surface 3 S4902- 0003 -6 9/2009 • • • I 111 111! •• • in Sound Output Ratings @ 10 ft ( -3 m) per UL 1480 Reverberant Chamber Testing Model Type Input Voltage Selected Tap 1/4 W 1/2 W 1 W 2 W 4902 -9716 4902 -9717 Rectangular Housing 25 VRMS 80 dBA 83 dBA 85 dBA 88 dBA 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA 4902 -9721 Round Housing 25 or 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA Sound Output Ratings @ 3 m ( -10 ft) per ULC S541 Anechoic Chamber Testing Selected Tap Model Type Input Voltage 1/4 W 1/2 W 1 W* 2 W* (see note) (see note) 4902- 9716CA Rectangular Housing* 25 VRMS or 70.7 VRMS 77 dBA 80 dBA 83 dBA 86 dBA 4902- 9717CA 4902 -9721 CA Round Housing* 25 VRMS or 70.7 VRMS 79 dBA 82 dBA 85 dBA 89 dBA * NOTE: ULC Fire Alarm applications require use of 1 W or 2 W tap for Round Housing speakers; and 2 W tap for Rectangular Housing speakers. Speaker Polar Dispersion Reference (per ULC S541 Anechoic Chamber Testing) Attenuation Angle -3 dB 30° off -axis -6 dB 1 55 off -axis 4905 -9931 Adapter Plate Installation Reference 4905 -9931 Ada 4905 -9999 Optic Wire Gu (shown here reference only, be used on of mounting optic 2975 -9145 Box bly 4905 -9931 Adapter Plate Tyco is a registered trademark of Tyco International Services GnMH and is used under license. Simplex, the Simplex logo, and TrueAlert are trademarks of Tyco International Ltd. and its affiliates and are used under license. 93.Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4902- 0003 -6 9/2009 www. tycosafetyproducts- usa -wm. com C 1 2009 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.