HomeMy WebLinkAboutVAIL INTERMOUNTAIN BLOCK 6 LOT 19 � - — - � � � -_._- ,�- � �Y SEQUENCE OF OPERATIONS: LEGEND: � SYMBOL DEVICE MANUFACTURER PART MOUNTING QUANTITY � FACP Addressable cZ.� Q Z Fire Alarm Control Panel Ademco Vista 50P Mount on wall in manufacturer backbox � � � Q z � z � z w � O cn O � O KP m � W cn � J � � � �� Keypad Ademco 6139 Mount on wall in manufacturer backbox � ° � N � tn m �n > cn Q o p cr � o � W � ? Photoelectric Smoke Detector a ? = Q z � z = z O w/ Sounder Base ESL 449CST 4" square box 12 ¢ o � � o � � `� o w w = � Z � z g z � Heat Detector Chemetronics 601 4" square box 3 DEVICE Q Q � z � z � z � DESCRIPTION � � � Q Q � � o � � � 0 0 Sounder — for garage System Sensor PA400W Single gang box � y SYSTEM SMOKE OR HEAT DETECTORS X X X � � o ¢ -: a� ` � c � v o AC POWER LOSS X i� '�' _ � : 0 n /�\ � O � �4i N pp • GROUND FAULT X � y"'� � � ` � ` ° °�' � OPEN CIRCUIT X � v J GENERAL NOTES: � M ` 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER W STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. �� 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR FURTHER ,_J INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAvIS, PROGRAMMING AND _ DEVICE OPERATION. �^"," - �V - _ .�, � ' � = : w�._ � ,,�- . LL } DRAWING �IST: � � ._ , a � M 'p��a { PROJECT IN �ORMATION . � a � � � � SHEE� SHEET TITLE: SCO �NICK RESIDENCE � � � WIRING BETWEEN DEVICES p m � � SCOPE OF WORK SHALL BE 3—#18 AWG V D vA I L C O a � � FA-00 COVER SHEET, LEGEND, 29 3 5 BAS I N G DA�E C� � � � PAIR. (6 CONDUCTORS). FA—�1 BUILDING FLOORPLANS UAI � , CO �0 RAD � � EOLR �,_ o � o FACP F�I R E A�AR M SYSTEM � (1 typ) (3 tyP) (t2 tyP) AHJ: VAIL FIRE DEPARTMENT � �, APPLICABLE CODES; 2002 NFPA 72, �003 IFC, 2003 IBC � � - �� DIALER OCCUPANCY: GROUP R � ``� AT FRONT DOOR USE: SINGLE FAMILY HOME , TELE LINES Q � , KEYPAD WIRING SHALL DEDICATED i2ov FIRE ALARM AND DETECTION SYSTEM FOR SINGLE FAMILY RESIDENCE. _ � ��,- , _ � BE 2—#16AWG PAIR (4 SYSTEM INCLUDES SMOKE DETECTORS IN SLEEPING ROOMS, AREAS OUTSIDE � � CONDUCTORS) OF SLEEPING ROOMS AND STAIRWELL LANDINGS. HEAT DETECTORS ARE � � �- Z �,_ PROVIDED IN THE GARAGE, KITCHEN AI� LAUNDRY ROOMS. SMOKE � � � _ ' SYSTE M O N E- LI N E D IAG RAM DETECTORS WILL HAVE SOUNDER BASES FOR OCCUPANT NOTIFICATION. A W � � tr� CONTROL KEYPAD IS PROVID�D AT THE MAIN ENTRY. C� a� � _i i NOTE 1. NO T—TAPPING PERMITTED ON ANY CIRCUIT f�,� � � � NOTE 2. ALL WIRING TO BE 18AWG FPL. THE HOME BUILDER WILL PROVIDE THE ROUGH IN OF DEVICES AND WIRING � [�� � � OF SYSTEM. FIRE ALARM CONTRACTOR SHALL SUPPLY DEVICES, PANEL, � m = � K N O X B O X, T E R M I N A T I O N S A N D P R O G R�,M M I N G O F S Y S T E M. U J J ~ � . � ��T�S � (' O m ��e d ��� ��t'� ,- :�`�: , � �r"'� �� ,, '�'°� ��,;��. "� �"' � C..� W � ��'' �X �{�� v 8�_�s.�`�s, �? :�� . �.m ,..,� „� ,h �� ;E�t, � `� ` ��`� �j FIRE PROTECTION ENGINEER: W Q � z ? �(GG <t $�/I�I��j! �?�!��+-�L► 3�'''''�t G!fLwLr ;�'"" ,, ^ . .� . . , a � , , • �`'� � - _ _W �,,� SHANER LIFE SAFETY �,� r ��;�� � m �" � �.c� z cA d���e �;�s. �- �Qv ���� PO BOX 1073 •'�'��°. x'ti;;:��'�, � � O W .r. .� ,, ; �. p,,, cV U t� � ��. - �.. • n_ Y� _.___,- _ �---- �...,; * ` / �PS FRiSCO CO 80443 0� z��� ,F,_., �j• �N1 ��+v 7� � � dLf•t�Sll� `'Jcj f��G�oIL�NG• ��.s,.. � ___._ _ r �_ _ _ _ __ _....�,... : U;,q � �t:+_ � DRAWNBY DATE �W�,. ��-�r' �r� _ _r�w.��_�y PHONE. 970-409-9082 ��� ;,�;;�,� � , DLS 918105 .,�„ � ���vtd� 2�� l�a� � ��� �.,, FAX: 720-294-9849 ��,:•�•....... •��° f ��^�( ���` SHEET DESCRIPTION COVER SHEET ��,��q� LEGEND SHEET# FA-00 _ - -- - - -- - - -- - - - - - -- - - - -- -- � , . �\ , �I P ° I o ❑ c—� Scolnik Residence Ademco Vista 50P FACP ,�� c�PEN T� i(--11 Standby � � Scolnick Residence � uvirv�RM � Numbar of Current Total Current � - ��' EELOW 11,=_I, 2935 Basingdale Blvd., Vail, CO � Devlce Type Devlaes � (Amps) v (Amps) Zone List� , i �� Main FACP CPU 1 X 0.032 = 0.032 - --- 4193SN Senal lntertace 15 X 0.00015 - 0.00225 -- -- - y� �- -- - s—� 003 � � �OOT I, �..�� I r_LOFT- � i LDY 449CST Smoke Detectors 1� X 0.0007 = 0.0084 � 601 Heat Detectors 3 X 0 = 0 Device � � �� � " ° � �� �) '�a�� O � 1 6139 LCD Keypad 1 X 0.04 = 0.04 Address Device Typ� Floor Location/Descnption ���� � ;; � �; ;; � ;� �� , 001 SUM COLUMN FOR STANDBY LOAD � 0.08265 = AMPS 001 HEAT DETECTOR UPPER LAUNDRY �E�— f �Alarm Load ( I I I I I 002 SMOKE DETECTOR UPPER LOFT 1 STAIR MECH � Numbar of Current Totai Current 003 SMOKE DETECTOR UPPER DEN � Device Type Devices � � (Ampsj (Amps) 004 SMOKE DETECTOR UPPER TOP OF ENTRY STAIRS _.__ 4 � ' Main FACP CPU 1 X 0.032 = 0.032 005 HEAT DETECTOR UPPER GARAGE FACP �' �� 4193SN Senal Intertace 15 X 0.00015 = 0.00225 006 SMOKE DETECTOR UPPER ENTRY o05 449CST Smoke Detectors 12 X 0.04 = 0.48 007 SMOKE DETECTOR MAIN MASTER BEDROOM Q---..�```�,, a 601 Heat Detectors 3 X 0 = � 008 SMOKE DETECTOR MAIN BOTfOM OF STAIRS GARAGE " Q .° j 6139 LCD Keypad 1 X 0,16 = 0.16 � g PA400 Sounder 1 X 0.0208 = 0.0208 009 SMOKE DETECTOR MAIN STUDY \ c ' c x SUM COLUMN FOR STANDBY LOAD � 0.69505 = AMPS 0 1 0 S M O K E D E T E C T O R M A I N T O P O F S T A I R S (AC CPOWER) ' � � ' � 011 HEAT DETECTOR MAIN KITCHEN _ -_ ,;; n� � o � Standby Load � , _ Required Standby Time in Hours 0 1 2 S M O K E D E T E C T O R L O W E R S O U T H W E S T B E D R O O M � �� STAIR �I-- ° � � Current (Amps) _ I 013 SMOKE DETECTOR LOWER STAIR LANDING � °' `° � �).08265 X �T! 24� = 1.98 006 Q---�-� �; � � 014 SMOKE DETECTOR LOWER NORTHEAST BEDROOM �C� �� _0�,'J � ° � r Alarm Load Required Alarm Time in Hours Y+,,�.�.,�.��� ! Current (Amps) _ _� � � (15 MINUTES) 015 SMOKE DETECTOR LOWER NORTHWEST BEDROOM � KP C.n � M � ).69505 X 0.25 =� 0.17 0 1 6 S P A R E Add Standby and Alarm Load for Required � �_ �� 0 1 7 S P A R E � �-�� � � 2.16 Q18 SPARE �4-- Ampere Hour Battery , THRU Multiply by the Derating Factor of 1.2 � 040 SPARE K��Ox Box J � Total Am ere Hours Re uired � � _ �2•59 ' p G � tBatteries Provtded: 7AH Minimum (/11`) . � _� _.�L�� � _ NoR�rti �{/ F Note: Current for heat and smoke detector supervision is accaunted for in 4193SN modules. �_ ; � � Smoke detector alarm current reflects current for built in sounder__����� _ UPPER LEVEL FLOOR aLAN � � - - SCALE: 1/8"=1' � o i � � i 0 S 0 o G • � � U C p � � m v . a � � BDRM 3 . DINING MSTR ROOM - BDRM 2 �_-� �___, LIVING II ROOM 015 ''—�\ II I� 2 ii i� O_ BA 3 . \? �i i� �� �1 �� - -— - -- � �014 ��--J I—� � I I E�`- � M � HOT U =_ ---- -_ — — � - f--- — - - - � - - DECK - - - - -- --- � HALL ?O��___�- � �------0 010 � Y BDRM 4 � KITCHEN� � STUDY �j W a � � 012 DECK 011 / M � ? � / BA 2 � � �)-71 � � �/ � �; 7C r � � y � 009 � W I I � HALL V Z I ( � t'r� J�.� r�a��i`�L � � � ` �` O Z - - - - - '-�U? -- Z � � Z � 008 �� w J � ( 0 � � � � �� � C� W = MSTR / W Q J 1 _ BDRM � � � ' J � I, u��c a swasir ncar aeo� � Y J O atu�r►r�►o mnar�wE • � �� m = m �eur, � � ' U = W W ! QECK 007� � i I Z ¢ � C� i � ' �' � uE a c�n.00�►�o�c - - � -- o�- -__ -_❑o � Q L� wa�ac n m eux. \ A 1 ' � (,' 0 m rr 0'� ;+�G`/r z � � . . V . , 1- Cn � W � - - -- - -- __�_��.��, 0 � m � � � ��. , 0 �.n z - _,fi M Q W NoaTM r NoRni 3 �.��' �.r'.�SA � N V � � �,� � � ��. ,� , ;�-�, p� �. p;,�,e_R �`�" s;�� •''1.EI �/�;.c�� E.,,.���� !�..� �i..�L� i� 'i��,Y'r"'-`,;4�"� �;f'✓`.j+.�E"`� �.�� •� �/:�• g°,�j��(1 DRAWN BY DATE LOWER LEVEL FLOOR PLAN ����,�;�4;av ;�� ;y���p;��r� t� MAIN LEVEL FLOOR PLAN o,� SCALE 1/8��_�� :��:;��:�•3��,� ��� .��w��� � SCALE; �ia��_�� �;� 52 �;� DLS 9/8/05 ,�.. . � .'� SHEET DESCRIPTION �k \+ ��� NOTE: CEILINGS ARE SMOOTH AND FLAr UNLESS S��Q�AL�� COVER SHEET ��_��� OTHERWISE NOTED. CEILING HEIGHT IS 9' THROUGHOUT. LEGEND zy..,�,. �y ,,,��,. —1 ��� SHEET# FA-01