HomeMy WebLinkAboutF11-0001TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit # Job Address: 728 W LIONSHEAD CR VAIL Status ... : Location.....: RITZ CARLTON RETAIL SPACE 3 (POSH HAIRS Applied .. : Parcel No...: 210107223120 Issued. . . Project No Expires. .: OWNER RCR LLC PO BOX 959 AVON CO 81620 APPLICANT WESTERN STATES FIRE 7026 S TUCSON WAY ENGLEWOOD CO 80112 License: 338 -S CONTRACTOR WESTERN STATES FIRE 7026 S TUCSON WAY ENGLEWOOD CO 80112 License: 338 -S 01/13/2011 PROTECTI 01/13/2011 PROTECTI 01/13/2011 Fl 1 -0001 ISSUED 01/13/2011 01/25/2011 Phone: 303 - 792 -0022 Phone: 303 - 792 -0022 Desciption: RELOCATE TWELVE SPRINKLER HEADS WITH SEMI - RECESSED DUE TO NEW TENANT REMODEL. Valuation: $3,630.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > $586.28 Plan Check --- > $432. 00 DRB Fee --------------------- > $0.00 Additional Fees------ - - - - -> $0.00 Investigation -> $0.00 TOTAL FEES--------- - - - - -> $586.28 Total Permit Fee ---------- > $586.28 Will Call - - - - -> $0.00 Payments ------------------- > $586.28 BALANCE DUE --------- > $0.00 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 01/17/2011 mvaughan Action: AP pending use approval from council CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SIGNATUfE OF /OWNED OR 0ONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADO Statement Statement Number: R110000065 Amount: $586.28 01/25/201111:45 AM Payment Method: Check Init: SAB Notation: 120632 W.S.F.P. ----------------------------------------------------------------------------- Permit No: Fll -0001 Type: SPRINKLER PERMIT Parcel No: 2101 - 072 - 2312 -0 Site Address: 728 W LIONSHEAD CR VAIL Location: RITZ CARLTON RETAIL SPACE 3 (POSH HAIR S Total Fees: $586.28 This Payment: $586.28 Total ALL Pmts: $586.28 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 SPRINKLER PERMIT FEES 154.28 PF 00100003112300 PLAN CHECK FEES 432.00 ant of Community Development 75 South Frontage Road Vail, Colorado, 816570, Tel:. 970- 479 -2128x �? Fax 970- 479 -2452/ Web: www.vailgov:c � e i C rrii FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: 1031 South Frontage Road Space C (Number) (Street) Building /Complex Name: V Rit Ca rlt o n Contractor Information: Company: Western States Fire Protection Company Address: 7026 S. Tuscan Way City: Centennial Contact Name: Joe Hayden (Suite #) Office Use: 0( - -- V07 - 000( 1 0 Project #: PR, / d — 0 , Building Permit #: Sprinkler Permit #: DOC Lot #: Block # Subdivision: Detailed Description of Work: Relocate (12) sprinkler State: CO Zip : 80112 heads with semi - recessed due to new tenant remod Contact Phone: 303 - 549 -8979 E -Mail joe.hayden @wsfp.us Town of Vail Contractor Registration No.: 338 -S X a Contractor Signature (required) Jum Property Information Parcel #: 210107223120 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Posh Hair Salon Owner Name: Vail Resorts Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler $: $3,630.00 (use additional sheet if necessary) Detailed Location of Work: Work will be preformed in retail space C f�f LSi MR i,- SfjLD,: Does a Monitored Fire Alarm Exist? Yes ( ,,) No ( ) Does a Sprinkler System Exist? Yes(. No( ) Work Class: New ( ) Addition ( ) Remodel Repair ( ) Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial Restaurant ( ) Other ( ) Date Received: oI \9 c 13 JAN iW 2011 M TOWN OF VAIL 01- Feb -l0 I///\ Western States v Fire Protection Co. p .dufea acsd Sao Material Submittal FOR POSH HAIR SALON VAIL RITZ CARLTON 1031 SOUTH FRONTAGE ROAD VAIL, CO 81658 Tenant Finish Prepared by: Jeff Hagan Project Manager Western States Fire Protection Co. 7026 S. Tucson Way Centennial, CO 80112 Phone (303) 792 -0022 Fax (303) 792 -9049 Cell (303 -549 -9553 Email jeff.hagan @wsfp.us WSFP #CS11097 January 13, 2011 11 Model F1 FR Recessed Sprinkler Types Recessed Pendent Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) 5. NYC BS &A No. 587 -75 -SA 6. Meets MIL- S -901C and MIL -STD 167 -1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93 -E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model F1 FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Bulletin 136 Rev.M Model F1 FR Recessed Quick Response Sprinklers Recessed Pendent (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. c m 1 The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 MATERIAL INDEX "Because of the current escalation occurring with steel, WSFP reserves the right to substitute pipe as required to meet project schedules. Description Model Manufacturer 1. Sprinkler Head A. Standard Spray Quick Response Semi - Recessed Pendant Sprinkler FIFR Reliable II. Pipe — 1 -1/4" and smaller threaded A. Black Schedule 40 Pipe ASTM A 795 Varies" III. Cast Iron Fittings Varies Varies" IV. Pipe Hangers (Per NFPA 13) A. Concrete Drop in Anchors HDI -P 3/8 Hilti B. All Thread Rod Fig. 100 Tolco C. Adjustable Ring Hanger Fig. 200 Tolco "Because of the current escalation occurring with steel, WSFP reserves the right to substitute pipe as required to meet project schedules. Model F1 FR Quick Response Recessed Pendent Sprinkler I Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Approval Sprinkler Identification Height Organizations Number (SIN) HOLE IN CEILING us Metric ?2' (15mm) y" NPT (RYz) 5.6 80 2.2" (5 6mm) 1,2,3,4,5,7,8 R3615 _ 1 CEI!lNfi l " (20mm) Y NPT (R 8.0 115 2.3" (58mm) 1,2,3,8 R3612 (11 mm) y "NPT(RI/2) 4.2 60 22'(56mm) 1,2,8 R3613 38' (10mm) y"" NPT (R'/1) 2.8 40 2.2" (56mm) -- 1,2,8 R3611 10mm F% 4.2 60 56mm 4,7 R3614 I' Refer to escutcheon data table for approvals and dimensions. 1/8 13.1mm1 1 _0. ? 17131 - DM j71.1mm1 136FG01 _ f (1) RCFEP T^ FI d F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DMENSONS. 1 1 14• HOLE DA. 371mmJ IS /16• pA jA9.ZmmJ HOLE IN CEILING TURN COLLAR UN k DCHT AC4NST SPRINKLER WRCNYH Bp55 !' x 112• REDUCER CUP fl I i I I FACE OF fll11AC IL ADJUS TMENT hl _ 1 CEI!lNfi l 0'J vs 1/8 13.1mm1 1 _0. ? 17131 - DM j71.1mm1 136FG01 _ f (1) RCFEP T^ FI d F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DMENSONS. 2. 1 518" DIA. [66.7mm1 HOLE IN CEILING 1 5116 DLA, [58.7mml CUP r I 112' REDUCER � I L _J CEILING 00 da FACE OF F ?T/NG TO FACE OF CEILING DIUENSION,,� 1 r} A T1 ADJUSTAlfNT IJEi':05_A (1) REFER TO FP ESCUTCHEON DATA THOLE FOR APPROVALS AND DIMENSIONS. 2. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1 FR Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model F1 FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1 FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings A (1) Not available for recessed sprinklers. Escutcheon Data •I Foridr," An Face of Fitting Modal Approvals Adjustment DI n sion to Calling or Wall Dimension Sprinkler Escutcheon z Classification Temperature Max. Ambient Bulb F1 Temp. Color 'C 'F 1 Y116 " (5mm - 17mm) Ordinar Min Recess Y. " (5mm - 24mm) FP Ordinary 68 155 10o'F(38 °C) Red Intermediate 93 200 150- F(66'C) Green High (t) 14 286 225'F(1o7'C) Blue A (1) Not available for recessed sprinklers. Escutcheon Data •I Foridr," An Face of Fitting Modal Approvals Adjustment DI n sion to Calling or Wall Dimension No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1 Recessed Pendent Recessed Horizontal Fl Finishes (1)(2) Standard Finishes Sprinkler Escutcheon z 1y „ F2 1,2,3,4,5,7,8 Max Recess F1 1,2,4,8 Max Recess (38.1 mm) 3;8` 1 Y116 " (5mm - 17mm) Min Recess Y. " (5mm - 24mm) FP 1,2 Max Recessed j mm 1y" (38.1 mm) 19.1mm No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1 Recessed Pendent Recessed Horizontal Fl Finishes (1)(2) Standard Finishes Sprinkler Escutcheon z Brass Chrome Plated (3) White Painted (3) F2 1,2,3,4,5,7,8 Max Recess (38.1 mm) Ye - 'Y,a ll Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome Min Recess 1 Y116 " (5mm - 17mm) 24mm FP 1,2 Max Recessed j mm 1y" (38.1 mm) 1 PushoN Thread -off 1,2 Min Recessed 1 "(25.4mm) (24 m s m) No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1 Recessed Pendent Recessed Horizontal Fl Finishes (1)(2) Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated (3) White Painted (3) Chrome Plated White Polyester Coated S pecial A p Ip icatl Finishes Sprinkler Escutcheon Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome ( Other finishes and colors are available on special order. Consult the factory for details. ( FM Approvals is limited to bronze and brass, chrome or black plated finishes only. ( FP Push- on/Thread -off escutcheon Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1 FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable The Reliable Automatic Sprinkler Co., Inc. (800)431 -1588 Sales Offices (800)848 -6051 Sales Fax (914)668 -3470 Corporate Offices www.reliablesprinkler.com Internet Address ® Recycled Paper Revision lines indicate updated or new data EG. Printed in U.S.A. 7105 PIN9999970027 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot -dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. Schedule 40 Pipe 1 1.315 1.049 1.68 Ibs /ft 70 1 1/4 1.660 1.380 2.27 Ibs /ft 51 1 1/2 1.900 1.610 2.72 Ibs /ft 44 2 2.375 2.067 3.66 Ibs /ft 30 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. n 1819 Clarkson Road For additional information, C �L us ( v� Chesterfield, MO 63017 contact your salesperson J t BULL MOOSE TUBE COMPANY (800) 325 -4467 today at (800) 325 -4467 or ltsrEo CJ FAX: (636) 537 -2645 (636) 537 -2600 in the USA, www.bullmoosetube.com or from Canada FM ACA A company e-mail: salesO)bullmoosetube.com call (800) 882 -4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 ill PICTORIAL TABLE OF CONTENTS Cast Iron (Continued) CAST IRON DRAINAGE FITTINGS ra I & Fig. 701 Fig. 7018 90" Short Turn Elbow 90" Reducing Short Turn Elbow Size Range: 1' 12* thru 4" Sizes: 1 & 2" vi Fig. 722 Fig. 723 Tee Reducing Tee Sizes: 1 12' & 2" Size: 2" x 2" x 1'/i www.anvilind.com 9 MMIM" 4.3.9 HDI -P Drop -In Anchor 4.3.9.1 Product Description 4.3.9.2 Material Specifications 4.3.9.3 Technical Data 4.3.9.4 Installation Instructions 4.3.9.5 Ordering Information Listinas /Aoarovals ICC -ES (International Code Council) ESR -1291 COLA (City of Los Angeles) Research Report No. 25350 Factory Mutual (FM) Pipe Hanger Components for Automatic Sprinkler Systems 4.3.9.1 Product Description The Hilti HDI -P Drop -In anchor is an internally threaded, flush mounted expansion anchor for solid and hollow concrete. Product Features Guide Specifications • Optimized 3/4" anchor length to allow reliable fastenings in hollow core panels, precast plank & post tensioned slabs • Shallow drilling enables fast installation • Lip provides flush installation, consistent anchor depth and easy rod alignment • Setting tool leaves mark on flange when anchor is set properly to enable inspection & verification of proper expansion Expansion Anchor Expansion anchors shall be flush or shell type and zinc plated in accordance with ASTM B 633, SC 1, Type III. Anchors shall be Hilti HDI -P anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits. Install anchors in accordance with manufacturer's recommendations. 4.3.9.2 Material Specifications The HDI -P is manufactured from mild carbon steel, which is zinc plated for corrosion protection in accordance with ASTM B 633, SC 1, Type III 4.3.9.3 Technical Data HDI -P Specification Table Desc. Length in. (mm) Bit Size' in. Average Ultimate Loads, lb (kN) Allowable Loads, lb (kN) 4000 psi Concrete (27.6 MPa) Hollow Core (Spancrete) 4000 psi Concrete (27.6 MPa) Hollow Core (Spancrete) Tension Shear Tension j Shear Tension Shear Tension Shear HDI -P 3/8 3/4(19.1) 1/2 1900 (8.5) 3000 (13.3) 2100 (9.3) 4000 (17.8 ) 380 (1.7) 600 (2.7) 420 (1.9) 800 (3.6) 1 For Hilti matched tolerance carbide tipped drill bits, see section 8.4.1. 4.3.7.4 Installation Instructions 1. Set depth 2. Hammer -drill 3. Clean hole. 4. Insert anchor. 5. Insert setting 6. Collar of set - gauge on drill. hole. tool and strike ting tool will with hammer leave an until anchor is indentation fully set. on flange of 4.3.9.5 Ordering Information anchor when HDI -P Anchor properly expanded. Item No. Description Box City 00283611 HDI -P 3/8 100 Setting Tools for HDI -P Anchors Item No. Description 00283611 HSD -G 3/8" - 3/4" Setting Tool w/ hand guard 00253784 HST -P 3/8" - 3/4" Settina Tool 256 Hilti, Inc. (US) 1- 800 - 879 -8000 1 www.us.hilti.com I en espanol 1 -800- 879 -5000 1 Hilti (Canada) Corp. 1- 800 - 363 -4458 1 www.ca.hilti.com 1 Product Technical Guide 2006 Component of State of California OSHPD Approved C � ps LIMB Seismic Restraints System Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10' lengths Material — Carbon Steel Maximum Temperature — 750 °F Finish — Plain Note —Available in Electro- Ga Ivan ized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish ® OFFICEIMANUFACTURING FACILITY - 1375 SAMPSON AVE. - CORONA, CA 92879 - PH: 951.737.5599 - FAX: 951.737.0330 CUSTOMER SERVICE - 800.786.5266 www.tolco.com Dimensions - Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650 °F 750 °F Wt. /100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1 1 /4 8000 7140 360 1 11630 10370 510 ® OFFICEIMANUFACTURING FACILITY - 1375 SAMPSON AVE. - CORONA, CA 92879 - PH: 951.737.5599 - FAX: 951.737.0330 CUSTOMER SERVICE - 800.786.5266 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2 ") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2 thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8 ") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8 "). Conforms to Federal Specifications WW -H -171 E, Type 10 and Manufacturers Standardization Society SP -69, Type 10. Maximum Temperature — 650 °F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTm Fig. 200WON. Order By — Figure number and pipe size c UL us usTEo FM OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 • CUSTOMER SERVICE • 800.786.5266 www.tolco.com Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 3 2 400 11 3/4 3/8 8mm or 10mm 3 2 +h 400 11 1 3/8 8mm or 10mm 3Y8 2 400 12 1 1 /4 3/8 8mm or 1 Omm 3 8 /4 2 400 13 11/1 3/8 8mm or 10mm 3 2 400 14 2 3/8 8mm or 10mm 4 3 400 15 c UL us usTEo FM OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 • CUSTOMER SERVICE • 800.786.5266 www.tolco.com