Loading...
HomeMy WebLinkAboutB11-0007 NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES �� �ow�o�vn� ' Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD/ALT MF BUILD PERMIT Permit #: B11-0007 Project #: PRJ10-0720 Job Address: 1160 CASOLAR DEL NORTE DR VAIL Status. . : ISSUED Location......: UNITA Applied . . : 01/31/2011 Parcel No....: 210301414006 Issued... : 04/01/2011 Expires. ..: 09/28/2011 OWNER VAILASSOCIATES LLC 01/31/2011 4 OLD STABLE WAY COLTS NECK NJ 07722 APPLICANT BLUE DEVIL BUI�DERS, INC. 01/31/2011 Phone: 317-260-0735 PO BOX 3398 VAIL CO 81658 License: 1051-B CONTRACTOR BLUE DEVIL BUILDERS, INC. 01/31/2011 Phone: 317-260-0735 PO BOX 3398 VAIL CO 81658 License: 1051-B Description: DEMOLISH AND REUILD THREE LIVING ROOM WALLS, RELOCATE FIREPLACE, INSTALL NEW WINDOWS AND NECESSARY SIDI NG/TRIM. Occupancy: Valuation: $35,500.00 Type Construction: Total Sq Ft Added: 0 ..,.....�.,,..>....................,,.,,.....,,,...�,,.....,,.........,,,,....�,..... FEE SUMMARY ......>.,..,....,,..........,.>,,,,.x..............,,>...,.......,....,.....,.,,,. Building Permit Fee------> $502.35 Will Cal Fee---------------------> $5.00 Total Calculated Fees-------------> $1,343.88 Plan Check--------------------> $326.53 Use Tax Fee---------------------> $510.00 Additional Fees-----------------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES-------------> $1,343.88 Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00 Payments------------------------------> $1,343.88 Total Calculated Fees--------> $1,343.88 BALANCE DUE-----------------------> $0.00 .........................................,..>...........�,.............,........,,..,.,.�,._.....,,�..............................,...........,,,.................»....,...,,...�...,...., DECLARATIONS 1 hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the informatior as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM-4:00 PM. ] �,� __ , ���._�.__,_._ � r / Signature of Owner or Contractor D te �O vt'1�.5 � l.—�'v''"�i�',,7 Print Name b I d_a It_co n st ru ct i o n_pe rm it_041908 t*��#***�*���fM�#**�Nw+w###wwwwwwwlf�kk*R�fRf�klxf**��xk�***wAfw+kwwwww*kwlwwwwwwwYffwww##wwf#wrtw�wwwYk/!��####�*#��!!�**�f*�#A��#lf��l���f��*1lx����x�***����*�k*�M�*f*k�wwwfMwwwwwrt APPROVALS Permit#: 611-0007 as of 04-01-2011 Status: ISSUED ....................................«.,..<..�......,.,.,,....,.........,..,...,.,.....,......,.........�.,...�,..................,...,..............,................»..,............ Item: 05100 BUILDING DEPARTMENT 02/08/2011 Martin Action: CR See laser fiche 03/17/2011 Martin Action: AP Item: 05110 ELECTRICAL REVIEW 02/08/2011 Martin Action: CR 03/17/2011 Martin Action: AP Item: 05120 MECHANICAL REVIEW 02/08/2011 Martin Action: CR 03/17/2011 Martin Action: AP Item: 05130 PLUMBING REVIEW 02/08/2011 Martin Action: CR 03/17/2011 Martin Action: AP Item: 05400 PLANNING DEPARTMENT 02/03/2011 bgibson Action: AP plans routed to D-5 03/03/2011 Warren Action: AP Revisions approved by Planning Item: 05600 FIRE DEPARTMENT 02/17/2011 mvaughan Action: AP any change in scope shall be forwarded to fire department for further review. 03/16/2011 mvaughan Action: AP CO detection required. Fire place log set shall be installed per manufacture specs. After market glass doors shall be installed in accordance to manufacture instruction. Must be listed for use with Golden Blount 4224 model. ....x...........................................................�....,,,........,.,...,....,......,......x........>...,.,..,,......,.,,.,......,,,,.,......,,.,.,..,,,...,....,..,.... See the Conditions section of this Document for any that may apply. bld_a It_construction_permit_041908 ...................................�...,.........�......,..........,.,.,..,........».....,...................,,...............,...........,...............,.....,....,,.,.,,......... CONDITIONS OF APPROVAL Permit#: 611-0007 as of 04-01-2011 Status: ISSUED ...................»..,........,,,.,.......,..,......,,..........,........,,.....>.....«..........,,,,»....,......,...,...,.,...,.,........,.......................................... Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. b Id_a It_co n st ru ct i o n_p e rm it_041908 *********************************�*************************************************+******** TOWN OF VAIL, COLORADO � Statement ***********************************************************+**+**+***********�********+***** Statement Number: R110000250 Amount: $1, 033.76 04/O1/201101:44 PM Payment Method: Check Init: SAB Notation: 1187 BLUE DEVIL BUILDERS ----------------------------------------------------------------------------- Permit No: B11-0007 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2103-014-1400-6 Site Address: 1160 CASOLAR DEL NORTE DR VAIL Location: UNIT A Total Fees: $1,343 .88 This Payment: $1, 033 .76 Total ALL Pmts: $1,343 .88 Balance: $0.00 **********************+********************************************************************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 502.35 PF 00100003112300 PLAN CHECK FEES 16.41 UT 11000003106000 USE TAX 4% 510.00 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 ----------------------------------------------------------------------------- . s'�v,} "� � �a � - -� ''`��� x' ,� ,:� .. ._, :. .� _ .r .'_ .., :� .. _:. y '� _ � '.: .: .. _: .. _ .. .: . � .... �. :: ., ., : �-- : , ?, . . . . _.: "�,'�. . � ..:: ..,. � ._..:v . ..:,"'-. �,._-�-.- � �-�� . .,.��. ,.�:.,.. , ... , . ., ;: . :� . ..._ . ..-. ......_ . �..'. .';:-. ;. t . .. .. ... . .. „ '.,,� . . . . .: •- , • .... . ,, •.. 4 ; :: � ° �" _~ ' ` ' - - Departmenf of Community Deyelopmen� � � � � r �. : 4 S-.i vC� A � �. � " .: " r r � 75 South Frontage EZoad � F`�� � �` _ �` - r:. < � � ,* �' '� � ;> Va�l, Colorac�o S�"6.��,� r ti . ' S s� .L� y�.^„ ':z • - , �. ' .� ef 1 ' . ` .Fc. . � � i ,' •: �� �:,�, � ��� -� • . a;=� "�~ .,� � `�F'ei 9�0-����2-�� � r ' . r . �t; �..r a` .`i a •� r 3i. �(j }'•x' "kix�r� �` .,-E'§� �'°�$ �• " k �. ' . �} �� _ �..0 r�li�'�.`7�� ����� .�' iwy ' y-. s y .F .S � � �� _ � ��� � ; .�,� * � ; `��- . : �'lVeti �v`w�.'�`�a 1���� : � J _ � �=d�. .c �•'�na 5 . "-z.' � , �`' �',}� .� f�.r-,;�.�.'vf'4� ��- /'}� t: �ti�ii���x ` - > ' De��lnpmen�E��sevsr���o�'t�-tr���. �.tt� '°i 4� `'�Y'+ 'S,"�� '"Jm .s.�.. �� y� ��,. ="<�, --. � �.'�"r �t� ?� �����7���� �a� Z �x�� `-x^ '"�`'�'�-����^ a• .� �, ` �� _�����, j .?�_�_ __ �._v�_-_.'" . .y� '[x . . ,. ,. . _3 `<�=�' z,.a �S TRANSMITTAL FORM Revision Submittals: 1. "Field SeY'of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved&the permit is re-issued. 3. Fees for reviewing revisions are$55_00 per hour(2 hour minimum), and are due upon issuance. ;Permit#(s)information applies to: Attention: ( ) Revisions ' ` (x) Response to Correction �etter ' i � �� ��7 attached copy of correction (etter ' i ( ) Deferred Submittal } � ( ) Other ' i ; _,_..,.,..� i Project Street Address: � j i ��(oQ/� �Sb la,/ �r � � Description/List of Changes: ; i � , ' �(Number) (Street) (Suite#) � I��S�S I�'�o I��1• i iBui(ding/ComplexName: �So�'�� ��� �o'fe- � �S j���e- C�-�G 5 = f -- - � �r(2.����cc� S�2C S ; �Contact Information= �2 F � !Company: ��`��- �U/i � V�)���) �KC.• ! � t Sr,,o ke �o�4�1ph3 ;Company Address: �� �0 X ��`� j �'�f�LI �n(��OnS ;City: Va`� � State: CO Zip: ��65g � j , E 1 ;Contact Name: ��D�'"l�S ,�L v r n e y ���F.T�S e. ; � 3i1- Z�o - o�3s ; � I . �. �-3 , 5 t� t� � a � s� a i �Contact Phone: � �E-Mail bl��-d���1 ����Ide�� � "�' � � _ ; �`°'�, } � , I i � i '_ — _ ...�„�,�,�,�,� i �Revised ADDITIONAL Valuations (Labor 8�Materiats) � � s �(DO NOT include original valuation) � ! � I i � � !Building: $ � ;(use additional sheet if necessary) � i � ------— -----— —----•----- ' ----._....--------_._...: !Plumbing: $ � i $ � �Date Received: � � � � � � i Electrical: � D � � f j Mechanical: � � FEB � 5 �. �01� �Total: $ � t TQWi� OF VAIL tudio pinnato, Inc. architecture art Town of Vail Building Department Martin A Haeberle, CBO RE: B11-0007 Permit Revisions February 25,2011 Greetings Martin- Attached are revised drawings for 1160A Casolar Del Norte remodel. Architectural Comments: 1. Sheet A1 and A3 indicates that glazing to have a minimum of.35 u value and that NFRC sticker shall be on windows for framing inspection. Structural Comments See attached letter from Structural Engineer. Plumbing Comments: Sheet A1 shows gas piping plans with gas pipe sizing calculations. Mechanical Comments: Sheet A1 indicates size of proposed gas fireplace as 42" x 24" using 50,000 BTU/hr. Electrical Comments: Sheet A1 identifies location of required smoke and carbon monoxide detectors on first level. E�sting detectors exist on all other levels. Sheet A1 shows relocated electrical oudets at baseboard locations in compliance with article 250.52 NEC. Best Regards- Julie Spinnato,Colorado License #ARC 400806 February 25, 2010 Town of Vail—Department of Community Development Attn: Mr. Martin A. Haeberle 5 South Frontage Road Vail, CO 81657 RE: Rockwell Addition - (TOV#B11-0007) 1160.A Casolar Del Norte Vail, Colorado 81657 Dear Mr. Martin A. Haeberle: bPSE, LLC. is writing this letter in regards to comments submitted by the Town of Vail; pertaining to the Residential Addition/ Remodel Permit Application described above, dated February 8th, 2011. The following are our responses to the Structural comments, #1 and #2: 1. "Provide statement of special inspections on plans per section 1705.2 IBC.": The Specifications on Sheet 51.1 have been reviewed & revised, such that no special inspection should be required for the project. However, in the event of unforeseen conditions, I have included a Statement of Special Inspections on Sheet S1.1 as well. 2. "Owner to provide completed special inspection program bV an approved special inspection a�ency prior to permit issuance. See Town of Vail web pa�e for required forms and list of approved a�encies.": Based on the revisions to Sheet 51.1, no special inspections or agencies should be required for the project. We have reviewed the comments from the Town of Vail, and believe that all items were addressed so that the Structural Plans, Details &Specifications are complete. Please let me know if you have any additional questions, comments or concerns. Sincerely, Brian L. Puppe, P.E. Owner& Structural Engineer Page 1 of 1 Q DS Consulting, Inc. Asbestos Inspection and Sampling Report 1160A Casolar•Del Narte Dr-ive ir� Vail, CO 81657 Presented To: Mr.Alex Rockwell 4 Old Stable Way, Colts Neck, NJ 07722 Performed &Prepared By: Mr. Brandon Sinkbeil DS Consulting, Inc. PO Box 6864 Avon, CO 81b20 (970) 476-4182 EXECUTIVE SUMMARY On February 8,2011,Mr. Brandon Sinkbeil of DS Consulting,Inc.(DSC)perfarmed a limited inspection and asbestos bulk-sampling at 1160A Casolar Del Norte Drive in Vail, Colorado,in order to identify potentially hazardous friable and non-friable asbestos-containing materials (ACM) within portions of the above- referenced, single family residence scheduled to undergo a remodel. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containireg material(ACM) as a material containing more than 1%asbestos. Mr. Sinkbeil performed asbestos bulk-sampling of drywall and joint compound (surfacing materials) in a total of three (3)locations within the upstairs bedroom and living room of the residence (see 5ection IV for descriptions of sample locations). All three (3) bulk-samples were analyzed by Reservoirs Environmental, Inc. laboratory in Denver,CO (NVLAP#101896)with all three (3) laboratory results reporting as negative for asbestos (see Appendiar B for laboratory resrrlts). 2 PROiECT O�IERVIEW [. Introduction A limited inspection and bulk-sampling for ACM was conducted at 116flA Casolar Del Norte Drive in Vail, Colorado, by Mr. Sinkbeil on February 8, 2011, at the request of Mr. Thomas Burney with Blue Devil Builders. Mr. Sinkbeil is a Colorado State Certified Building Inspector, having EPA Accreditation #13442 (see Appendfat A for certificate]. The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non-friable ACM within the areas of the residence to be disturbed in the upcoming remodel. II. 5tructural Design The structure is a multilevel wood-framed,single-family residence with an attached garage. [li. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a limited number of bulk-samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk-samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to lorate and quantify suspect ACM. It should be nated that additional ACM might be located in these and other inaccessible areas. Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency(EPA) Final Rule: Title II of the To�cic Substances Control Act(TSCA), 15 USC,Sections 2b41 through 2654 and in compliance with 40 CFR� Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics a�d application. 3. Random sampling patterns detetmined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the EPA's Me hod for the Determination nf shactns in Rvlk RuildlTl,q MQtprinlc (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle AL1as as methods references. Analysis of the bulk-samples was performed on the"date reported,"as listed in the bulk-sample analysis report. 3 N. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing Mater�al: sprayed or troweled onto structural building member. Z. Thermal System Insulation(TSI):any type of pipe,boiler,tank,or duct insutation. 3. Miscellaneovs Material: other suspect materials, ftoor tile, sheet vinyl/tinoleum, ceiling tiles, insulation,and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significandy damaged"are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response-action recommendations for asbestos-containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1%within the bulk-sample, or a bulk-sample in the same HA,and should be addressed accordingly. A general recommendadon indicates asbestos does not exist greater than 1%within the bulk-sample, or all bulk-samples in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1%unless it is analyzed by the point-count method to be less than 1%. V. Inspector Comments No asbestos-containing material (ACM) was identified during the bulk-sampling conducted at 1160A Casolar Del Norte Drive in Vail, Colorado. A total of three (3) bulk-samples were collected from drywall in the above-referenced residence. All three (3) bulk-samples tested negative for asbestos. 4 VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent-asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at 1160A Casolar Del Norte Drive in Vail, Colorado, on February 8, 2011. The quandties are approximations and are subject to field verification: i � , • • � ' i t � � • � ' i Sample#: DW-01 Sample#:DW-02 Sample Description: Drywall&Texture Sample Description: Drywall&Te�cture Sample Location: Garage wall drywall Sample Location: Garage wall drywall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: >200 ftz Material Quantity: >200 ft2 Material Condition: Good Material Condition: Good Layers-Asbestos Content: Layers-Asbestos Cantent: White/brown drywall-ND White paint w/white compound-ND Beige paint w/white texture-ND Beige paint w/white texture-ND White brown d all-ND Recommendations: GENERAL-See Section Vll Recommendations: GENERAL-See Section VII s E � ° � ; - ° � Sample#:DW-03 Sample Description: Drywall&Texture Sample Location: Garage wall drywall Material Classification: Surfacing Material Material Quantity: >200 ftz Material Conditron: Good Layers-Asbestos Content: Bei e aint w white texture-ND Recommendattons: GENERAL-See Section Vll vit. Recommendations GENERAL: The laboratory results of the potential ACM sampled at 1160A Casolar Del Norte Drive in Vail, Colorado, indicate that all three (3) bulk-samples of drywall collected were reported as negative for asbestos. 5 Therefore, no professional abatement activides are recommended to remove the above-referenced material. . APPENDIX A CERTIFICATION ,_ _�__ - - .. . - -- -_ �., .t� .t Z .�� �.ar � � `# �. 3` � t''�,��'1 � �l ,�,e r��7�.�� �ti¢ 3"4 a�¢} ahi��"..�M,��y�;�.� r�� z�� !�r C `-�. � � �1►,A" �'w',i�`�. _'aM!'"�� '�,,1�'`'.4 �V► ,e". �..� ��.� r;�� . . �}► �_, . _ .. .a _:- - — �.�.,,.,_. _ £ j -. r t � -ic � ,��^ ��:�` STATE �F COLORADO :�;:�° �� ,� �.=. �- � _ � :�� AsB�sros � �- �� , .� , t= �` CERT1FtCATtON* l'' �� z�: f :�; � . ,. , � "'�-"_ �'s Cutvradu I)Cj731lIilCOI UI NUE)Ill'HC:tIIIl � � �� ' �� and Em•ir�r�ment s y- � {���; .4ir Pollution Control Division ,� r �� }t. t;.: �s �. � ._ "'�,*.� This Certitie�that -" ��-� �f_ Brandon Sinkbeil i ��' , ,F. � -=- }'-- �i' Ccrtificatioo No: 134�i2 �' i�.. S- S i�f:ii��.. �'�; ��1:: � ..« �° � . ., N �-�,�4t' has met the requirements of 25-7-507,C�.R.S.and:1ir()uality('cxitrul �` �s� �'��� ('ommissioR Regulation No.8,Part B.and is hereby certifiad hy�he °� : � < <_?�`:: �i,, statc of('oloradu in thc tollu�ving d�kirlinr- ��:;_'�` .�a _ �3 �. ib ' �° ��� � r,��r; Buiiding Inspector� E � r �,, ,� � ,u;:,r � �'"'-�• ; i��ucd: -�ibaato ���= � r � ' E�pir�y on: i/1(�2011 � r' , ', / 2..�" �--X�����1 j't � � j �~ ': � C. r � ����� ;? '�j'1`~ , � °� �. � z 1 :��' s� !�_. -rM�..�rnj:an;,wl:O.nlc.:rr ih�y..v...ww./.rr.nwr Di.:.si.nypFr.avl r�r..in�;�wrrr .. l..y��' .t � r.ttrlf+vnww ia rir dGc`IpHw.�y�mhN�bs�r Y . � p� r�'�.. � � , / �y� -�-�: ..`N � S' -� 5»«�':-_' ,, � �r. � i.�i� �,' .-'j �' .T'�� �. a�11 �!+ .-.l.F�.....����---n�Y �[ lt.�...��iMa �I%�n .��".i-°,e . BS.�a+.`�a�."'..,..�..:,.:y.a,.�Y:,i.-ct}yy�.-e•=y-., --`•.o•�y-,, •�:;r,, APPENDIX B LABORATORY ANALYSI5 7 REI LAB ��s�rvnirs Environm�ntal /nc. � February 11,2011 Laboratory Code: RES Subcontrad Number: NA Laboratory Report: Project�t/P.O.# Projed Desc�tion: Srandon Sinkbeil DS Consulting, tnc. 5366 Flatrodc Ct. Morrison CO 80465 Dear Customer, RES 207478-1 R None Given 1160A Casolar Del Norte Dr.,Vatl,CO 81657 Reservoirs Environmental, Inc. is an analytical laboratory acc�dited for the analysis of Industrial Hygiene and Environmental matrices by the Natiaral Voluntary Lab�atory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Mic.�oscopy (TEM) and Pdarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association(AIHA), L.a�b ID 101533-Accxeditation Certificate #480 for Phase Cor�ast Microscopy (PCM) analysis. This laboratory is curret�tiy proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed tfie fdlowing samples for asbestos content as per your request. The analysis has been completed in general acxordance with the appropriate methodology as stated in the attached analysis table.The results have been submitted to your office. RES 207479-1 R is the jab number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc.wi{I not discuss any part of this study with personnel other than those of the dienL The resuits descxibed in tfiis report only apply to the samples analyzed.This report must not be used to daim endorsement of produds or analytical resuiks by NVLAP or any agency of the U.S. Govemment. This report shall not be reproduced exc�pt in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested.If ya�have any questions about this report,please feel free to ca� 303-964-1986. Sincerely, �-a-Z-.,� _� -���! �-. ' Jeanne Spencer Orr President , ��u-ff-_ , 1J1-���--_ Analyst(s): Paul D.LoSca{zo Wenlong Liu Michael Scales Rich Wegrzyn Mita Grigg Robert R.Workman Jr. Bethany Nichols P:303-964-1986 5601 Logan Street,Suite 100 Denver,CO 80216 F:303-477-4275 Page 1 of 2 1-866-RESI-ENV www.reilab.com . � �nP�n coae�o�esso Tori�a�y�so.oi� TABLE PLM BULK ANALYSiS,PERGENTAGE COMPOSRION SY VOLU1rE RES Job Number. Client: Client Project Number/P.O.: Client Project Description: Date Samples Received: Analysis Type: Tumaround: Date Malyzed: F�S 2074T9-1R DS Coosulting,lnc. None Givett 1160A Casolar Del Norte Dr.,Vail,CO 81657 Felxuary 8,2011 PUII,Short Report 2 Hour February'11,20�1 Page 2 of 2 ent � Asbestos ontent on on Sample ID Number A Sub Asbesto Fibrou Number Y Physical Part Fibrous Component E Desniption (X) s (°� R E�ts 96 DW01 EM 695928 A V4�ehxoNm drywall 40 50 50 B Beige paint w/white te�Qure 60 ND 0 100 DW02 EM 695929 A White pairrt w/white c�xnpound 10 ND 0 100 B Beige paint w/white texture 45 ND 0 100 C WixteJbrown drywaN 45 50 5Q DW03 EM 695930 A Beige paint w/white te�mre 100 0 100 N!l-Nonc I)ctocicd 1R=Tnu.<l`F�YwW Fstim� TrrnrAcaTrrnxilitc-Acriru�}itc Note:FMI�wly�is by 7'GIN ic rtc��(ur aganidly 6aood ma�l li.a floar tilcl if PLM rcmlcc aic<1 k. Data QA � ��o. � Z , � __---� A�f� �� � �,� ��'� �,�,. Department,of Communi#y Development� ��,*� � �'��,��' �� �° � �'� ,�.��� � ` � .� 75 South Frontage Road �-�; �h � �:- _� �.� '�� �{:� Vail, Colorac�o 81�65�`=� �� -�---`� . �� �' , �� fTel. 970-479 2'���i.`� �_.� �� - °�,- Web:R www va�lgov cor�n�° ,, : �a i:� `�� �� °�q ���'` Develop�rient;Re�inr Coordma#ca�=� -� �., , .� � �� � �.._..� r���:�. `��� .. �� �� ;:'-: ��' '� , `,� �'''-� �+� "�� �`������'� . � . j� � . � - ..�����tr�� � ' . ��' . w- � ,�. -^�y-, x.�' ,k'�` . .. �..-.,.. . ., ., Y . .. �. . �_.'�ta'.� . �. . _ ._. BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: Project#: �����' ��v�,� ��v '� ``_`��c��� �z-� lV.;�`e� :1 ��-�l' l� ._ t� ao� (Number) (Street) (Suite#) DRB#: Building/Complex Name: l�� ��u' I/� , ��L '�z Building Permit#: '— Lot#: Block# Subdivision: Contractor Information Business Name: ���� (J�V� I �v� �c�2%� Work Class: New( ) Addition ( x ) Alteration ( ) Business Address: �°x 3 S�g Type of Building: City V�" � State: �-U Zip: ���%�g Single-Family O Duplex(x) Multi-Family O Contact Name: �vv�tc�� �;v r�.e� Commercial ( ) Other( ) Contact Phone: J I I ��IID � l3> Work Type: Interior O Exterior O Both (>C) Contact E-Mail: b1�¢� ��� � ��� ����`� L ��''"�``�� �`"� Valuation of Work Included Plans Included Work Contractor Registration Number: ,� . � Electrical (x)Yes ( )No (x)Yes ( )No '� �� �` X Mechanical (x)Yes ( )No ( Y)Yes ( )No "" 3 5vo Owner/Owner's Representative Signature(Required) Plumbing ( x)Yes ( )No ( )Yes (�[ )No �= �oc�o BUI�C�IfI ��,UJG Project Information n g ( %C)Yes ( )No (k)Yes ( )No � Owner Name: /1��-'-� ��(� `"�e'l� Value of all work being performed: $�_���J,�JQ� Parcel • ��v� "' ("'[ � —'1�6� �.� (value based on IBC Section 109.3&IRC Section 108.3� � r Parcel#,contact Eagle County Assessors O�ce at(970328-8640 or visit c� www.eaglecounty.uslpatie) Electrical Square Footage � Detailed Scope and Location of Work: �r��'� �c S��s� ��-� �`�O�1�" - ��'�o��5� ��"°� `���'�`� 3 liv.,� :�"�:��� �,.�� I�� J ������1� �, ��I�.�z� � ; ,�5 f-�-I1 vt��,.J �,1; ,do� � a,�� ���ce�S�,, �, S; �, .1��%-���- � ►� — f�i c� .� �0 5���c� (use additional sheet if necessary) � � ' — �p�r] � �' , rJs Q� � - OOO� � �3,75 For Office Use Only: Date Received: D � � � a `� � Fee Paid: ��j I�� I� )AN � Received From: r�LU�- (�ul� �u����F25 /N(" � z��� Cash Check # �� CC: Visa / MC Last 4 CC # exp date: T���n,� ��` �,/,��� Auth # ----t��_. ___�.�, �, 01-Jan-ll � ,_,, 06-02-2011 Inspection Request Reporting Page 6 _7:24 am Vail, �_� Of Requested Inspect Date: Thursday,June 02 2011 Site Address: 1160 CASOLAR DE`L NORTE DR VAIL UNIT A A/P/D Information Activity: B11-0007 Type: A-MF Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: VAIL ASSOCIATES LLC Contractor: BLUE DEVIL BUILDERS, INC. Phone: 317-260-0735 Description: DEMOLISH AND REUILD THREE LIVING ROOM WALLS, RELOCATE FIREPLACE, INSTALL NEW WINDOWS AND NECESSARY SIDING/TRIM. Reauested Inspectionls) Item: 90 BLDG-Final Requested Time: 09:30 AM Requestor: Phone: Comments: 317-26 - 735 Assigned To: *"" Entered By: MHAEBERLE K Action: Time Exp: Item. 534 PLAN -FINAL C/O Requested Time: 08:00 AM Requestor: Phone: Com ments: 317-260-0735 Assigned To: BGIBSON Entered By: MHAEBERLE K Action: Time Exp: � � � ���� �� Inspection Historv Item: 10 BLDG-FOOTING 04/12/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: Item: 20 BLDG-Foundation/Steel 04/12/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: Item: 410 Special Inspect-progress rept Item: 30 BLDG-Frammg *Approved*` 05/06/11 Ins�pector: JRM Action: AP APPROVED Comment: U VALUES CHECKED AND APPROVED .26 Item: 50 BLDG-Insulation "*A�pproved•* 05/06/11 Inspector: JRM Action: PI PARTIAL INSPECTION Comment: CEILING ONLY R50 05/12/11 Inspector: JRM Action: AP APPROVED Comment: Item: 60 BLDG-Sheetrock Nail **Approved"" 05/09/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: Ceiling only 05/11/11 Inspector: sgremmer Action: AP APPROVED Comment: 05/19/11 Inspector: JRM Action: AP APPROVED Comment: Item: 70 BLDG-Misc. Item: 420 S ecial Inspect-final rept Item: 90 BL�G-Final Item: 534 PLAN-FINAL C/O REPT131 Run Id: 13122