HomeMy WebLinkAboutB11-0007 NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
��
�ow�o�vn� '
Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
ADD/ALT MF BUILD PERMIT Permit #: B11-0007
Project #: PRJ10-0720
Job Address: 1160 CASOLAR DEL NORTE DR VAIL Status. . : ISSUED
Location......: UNITA Applied . . : 01/31/2011
Parcel No....: 210301414006 Issued... : 04/01/2011
Expires. ..: 09/28/2011
OWNER VAILASSOCIATES LLC 01/31/2011
4 OLD STABLE WAY
COLTS NECK
NJ 07722
APPLICANT BLUE DEVIL BUI�DERS, INC. 01/31/2011 Phone: 317-260-0735
PO BOX 3398
VAIL
CO 81658
License: 1051-B
CONTRACTOR BLUE DEVIL BUILDERS, INC. 01/31/2011 Phone: 317-260-0735
PO BOX 3398
VAIL
CO 81658
License: 1051-B
Description:
DEMOLISH AND REUILD THREE LIVING ROOM WALLS, RELOCATE
FIREPLACE, INSTALL NEW WINDOWS AND NECESSARY SIDI NG/TRIM.
Occupancy: Valuation: $35,500.00
Type Construction: Total Sq Ft Added: 0
..,.....�.,,..>....................,,.,,.....,,,...�,,.....,,.........,,,,....�,..... FEE SUMMARY ......>.,..,....,,..........,.>,,,,.x..............,,>...,.......,....,.....,.,,,.
Building Permit Fee------> $502.35 Will Cal Fee---------------------> $5.00 Total Calculated Fees-------------> $1,343.88
Plan Check--------------------> $326.53 Use Tax Fee---------------------> $510.00 Additional Fees-----------------------> $0.00
Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES-------------> $1,343.88
Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00
Payments------------------------------> $1,343.88
Total Calculated Fees--------> $1,343.88 BALANCE DUE-----------------------> $0.00
.........................................,..>...........�,.............,........,,..,.,.�,._.....,,�..............................,...........,,,.................»....,...,,...�...,....,
DECLARATIONS
1 hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the informatior
as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM-4:00 PM. ]
�,�
__ , ���._�.__,_._ � r /
Signature of Owner or Contractor D te
�O vt'1�.5 � l.—�'v''"�i�',,7
Print Name
b I d_a It_co n st ru ct i o n_pe rm it_041908
t*��#***�*���fM�#**�Nw+w###wwwwwwwlf�kk*R�fRf�klxf**��xk�***wAfw+kwwwww*kwlwwwwwwwYffwww##wwf#wrtw�wwwYk/!��####�*#��!!�**�f*�#A��#lf��l���f��*1lx����x�***����*�k*�M�*f*k�wwwfMwwwwwrt
APPROVALS
Permit#: 611-0007 as of 04-01-2011 Status: ISSUED
....................................«.,..<..�......,.,.,,....,.........,..,...,.,.....,......,.........�.,...�,..................,...,..............,................»..,............
Item: 05100 BUILDING DEPARTMENT
02/08/2011 Martin Action: CR See laser fiche
03/17/2011 Martin Action: AP
Item: 05110 ELECTRICAL REVIEW
02/08/2011 Martin Action: CR
03/17/2011 Martin Action: AP
Item: 05120 MECHANICAL REVIEW
02/08/2011 Martin Action: CR
03/17/2011 Martin Action: AP
Item: 05130 PLUMBING REVIEW
02/08/2011 Martin Action: CR
03/17/2011 Martin Action: AP
Item: 05400 PLANNING DEPARTMENT
02/03/2011 bgibson Action: AP plans routed to D-5
03/03/2011 Warren Action: AP Revisions approved
by Planning
Item: 05600 FIRE DEPARTMENT
02/17/2011 mvaughan Action: AP any change in
scope shall be forwarded to fire department for further
review.
03/16/2011 mvaughan Action: AP CO detection
required.
Fire place log set shall be installed per manufacture
specs. After market glass doors shall be installed in
accordance to manufacture instruction. Must be listed for
use with Golden Blount 4224 model.
....x...........................................................�....,,,........,.,...,....,......,......x........>...,.,..,,......,.,,.,......,,,,.,......,,.,.,..,,,...,....,..,....
See the Conditions section of this Document for any that may apply.
bld_a It_construction_permit_041908
...................................�...,.........�......,..........,.,.,..,........».....,...................,,...............,...........,...............,.....,....,,.,.,,.........
CONDITIONS OF APPROVAL
Permit#: 611-0007 as of 04-01-2011 Status: ISSUED
...................»..,........,,,.,.......,..,......,,..........,........,,.....>.....«..........,,,,»....,......,...,...,.,...,.,........,..........................................
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Cond: 14
(BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO
BE SEALED WITH AN APPROVED FIRE MATERIAL.
Cond: 1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
b Id_a It_co n st ru ct i o n_p e rm it_041908
*********************************�*************************************************+********
TOWN OF VAIL, COLORADO � Statement
***********************************************************+**+**+***********�********+*****
Statement Number: R110000250 Amount: $1, 033.76 04/O1/201101:44 PM
Payment Method: Check Init: SAB
Notation: 1187 BLUE
DEVIL BUILDERS
-----------------------------------------------------------------------------
Permit No: B11-0007 Type: ADD/ALT MF BUILD PERMIT
Parcel No: 2103-014-1400-6
Site Address: 1160 CASOLAR DEL NORTE DR VAIL
Location: UNIT A
Total Fees: $1,343 .88
This Payment: $1, 033 .76 Total ALL Pmts: $1,343 .88
Balance: $0.00
**********************+*********************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 502.35
PF 00100003112300 PLAN CHECK FEES 16.41
UT 11000003106000 USE TAX 4% 510.00
WC 00100003112800 WILL CALL INSPECTION FEE 5.00
-----------------------------------------------------------------------------
. s'�v,} "� � �a � - -� ''`��� x' ,� ,:�
.. ._, :. .� _ .r
.'_ .., :� .. _:. y '� _
� '.:
.: .. _: .. _ .. .:
. � .... �. :: ., ., : �--
:
, ?,
. . . . _.: "�,'�. . � ..:: ..,. � ._..:v
. ..:,"'-. �,._-�-.-
�
�-�� . .,.��. ,.�:.,.. , ... , . .,
;: . :� . ..._ . ..-. ......_ . �..'. .';:-.
;.
t
. .. .. ... . .. „ '.,,� . . . . .:
•-
, •
.... . ,, •..
4 ; ::
� ° �" _~ ' ` ' - - Departmenf of Community Deyelopmen� �
� � � r �. :
4 S-.i vC� A � �. � " .:
" r r � 75 South Frontage EZoad �
F`�� � �` _ �` - r:. <
� � ,* �' '� � ;> Va�l, Colorac�o S�"6.��,�
r ti . ' S
s� .L� y�.^„ ':z • - , �. ' .� ef 1 ' . ` .Fc. . � � i
,' •:
�� �:,�, � ��� -� • . a;=� "�~ .,� � `�F'ei 9�0-����2-��
� r ' . r . �t; �..r a` .`i a •� r 3i. �(j }'•x' "kix�r�
�` .,-E'§� �'°�$ �• " k �. ' . �} �� _ �..0 r�li�'�.`7�� �����
.�' iwy ' y-. s y .F .S �
� �� _ � ��� � ; .�,� * � ; `��- . : �'lVeti �v`w�.'�`�a 1���� :
� J _ � �=d�. .c �•'�na 5 . "-z.' � , �`' �',}� .� f�.r-,;�.�.'vf'4� ��- /'}� t:
�ti�ii���x ` - > ' De��lnpmen�E��sevsr���o�'t�-tr���.
�.tt� '°i 4� `'�Y'+ 'S,"�� '"Jm .s.�.. �� y� ��,. ="<�, --. � �.'�"r �t� ?�
�����7���� �a� Z �x�� `-x^ '"�`'�'�-����^ a• .� �, ` �� _�����,
j .?�_�_ __ �._v�_-_.'" . .y� '[x . . ,. ,. . _3 `<�=�' z,.a
�S
TRANSMITTAL FORM
Revision Submittals:
1. "Field SeY'of approved plans MUST accompany revisions.
2. No further inspections will be performed until the revisions are approved&the permit is re-issued.
3. Fees for reviewing revisions are$55_00 per hour(2 hour minimum), and are due upon issuance.
;Permit#(s)information applies to: Attention: ( ) Revisions '
` (x) Response to Correction �etter '
i � �� ��7 attached copy of correction (etter '
i ( ) Deferred Submittal }
� ( ) Other '
i ;
_,_..,.,..�
i Project Street Address: � j
i ��(oQ/� �Sb la,/ �r � � Description/List of Changes: ;
i � , '
�(Number) (Street) (Suite#) � I��S�S I�'�o I��1• i
iBui(ding/ComplexName: �So�'�� ��� �o'fe- � �S j���e- C�-�G 5 =
f -- - � �r(2.����cc� S�2C S ;
�Contact Information= �2 F �
!Company: ��`��- �U/i � V�)���) �KC.• ! � t Sr,,o ke �o�4�1ph3
;Company Address: �� �0 X ��`� j �'�f�LI �n(��OnS
;City: Va`� � State: CO Zip: ��65g � j
, E 1
;Contact Name: ��D�'"l�S ,�L v r n e y ���F.T�S e. ;
� 3i1- Z�o - o�3s ; � I . �. �-3 , 5 t� t� � a � s� a i
�Contact Phone: �
�E-Mail bl��-d���1 ����Ide�� � "�' � � _
; �`°'�, } �
,
I i �
i '_ — _ ...�„�,�,�,�,� i
�Revised ADDITIONAL Valuations (Labor 8�Materiats) � �
s
�(DO NOT include original valuation) � !
�
I
i � �
!Building: $ � ;(use additional sheet if necessary) �
i � ------— -----— —----•----- '
----._....--------_._...:
!Plumbing: $ �
i $ � �Date Received: � � � � � �
i Electrical: � D
� � f
j Mechanical: � � FEB � 5
�. �01�
�Total: $ � t
TQWi� OF VAIL
tudio
pinnato, Inc.
architecture art
Town of Vail Building Department
Martin A Haeberle, CBO
RE: B11-0007 Permit Revisions
February 25,2011
Greetings Martin-
Attached are revised drawings for 1160A Casolar Del Norte remodel.
Architectural Comments:
1. Sheet A1 and A3 indicates that glazing to have a minimum of.35 u value and that NFRC
sticker shall be on windows for framing inspection.
Structural Comments
See attached letter from Structural Engineer.
Plumbing Comments:
Sheet A1 shows gas piping plans with gas pipe sizing calculations.
Mechanical Comments:
Sheet A1 indicates size of proposed gas fireplace as 42" x 24" using 50,000 BTU/hr.
Electrical Comments:
Sheet A1 identifies location of required smoke and carbon monoxide detectors on first level.
E�sting detectors exist on all other levels.
Sheet A1 shows relocated electrical oudets at baseboard locations in compliance with article
250.52 NEC.
Best Regards-
Julie Spinnato,Colorado License #ARC 400806
February 25, 2010
Town of Vail—Department of Community Development
Attn: Mr. Martin A. Haeberle
5 South Frontage Road
Vail, CO 81657
RE: Rockwell Addition - (TOV#B11-0007)
1160.A Casolar Del Norte
Vail, Colorado 81657
Dear Mr. Martin A. Haeberle:
bPSE, LLC. is writing this letter in regards to comments submitted by the Town of Vail; pertaining to the
Residential Addition/ Remodel Permit Application described above, dated February 8th, 2011. The following
are our responses to the Structural comments, #1 and #2:
1. "Provide statement of special inspections on plans per section 1705.2 IBC.": The Specifications on
Sheet 51.1 have been reviewed & revised, such that no special inspection should be required for the
project. However, in the event of unforeseen conditions, I have included a Statement of Special
Inspections on Sheet S1.1 as well.
2. "Owner to provide completed special inspection program bV an approved special inspection
a�ency prior to permit issuance. See Town of Vail web pa�e for required forms and list of
approved a�encies.": Based on the revisions to Sheet 51.1, no special inspections or agencies should
be required for the project.
We have reviewed the comments from the Town of Vail, and believe that all items were addressed so that
the Structural Plans, Details &Specifications are complete.
Please let me know if you have any additional questions, comments or concerns.
Sincerely,
Brian L. Puppe, P.E.
Owner& Structural Engineer
Page 1 of 1
Q
DS Consulting, Inc.
Asbestos Inspection and Sampling Report
1160A Casolar•Del Narte Dr-ive ir� Vail, CO 81657
Presented To:
Mr.Alex Rockwell
4 Old Stable Way,
Colts Neck, NJ 07722
Performed &Prepared By:
Mr. Brandon Sinkbeil
DS Consulting, Inc.
PO Box 6864
Avon, CO 81b20
(970) 476-4182
EXECUTIVE SUMMARY
On February 8,2011,Mr. Brandon Sinkbeil of DS Consulting,Inc.(DSC)perfarmed a limited inspection and
asbestos bulk-sampling at 1160A Casolar Del Norte Drive in Vail, Colorado,in order to identify potentially
hazardous friable and non-friable asbestos-containing materials (ACM) within portions of the above-
referenced, single family residence scheduled to undergo a remodel. The Colorado Department of Public
Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containireg material(ACM) as
a material containing more than 1%asbestos.
Mr. Sinkbeil performed asbestos bulk-sampling of drywall and joint compound (surfacing materials) in a
total of three (3)locations within the upstairs bedroom and living room of the residence (see 5ection IV for
descriptions of sample locations). All three (3) bulk-samples were analyzed by Reservoirs Environmental,
Inc. laboratory in Denver,CO (NVLAP#101896)with all three (3) laboratory results reporting as negative
for asbestos (see Appendiar B for laboratory resrrlts).
2
PROiECT O�IERVIEW
[. Introduction
A limited inspection and bulk-sampling for ACM was conducted at 116flA Casolar Del Norte Drive in Vail,
Colorado, by Mr. Sinkbeil on February 8, 2011, at the request of Mr. Thomas Burney with Blue Devil
Builders. Mr. Sinkbeil is a Colorado State Certified Building Inspector, having EPA Accreditation #13442
(see Appendfat A for certificate]. The purpose of the inspection was to identify, sample and assess
potentially hazardous friable and non-friable ACM within the areas of the residence to be disturbed in the
upcoming remodel.
II. 5tructural Design
The structure is a multilevel wood-framed,single-family residence with an attached garage.
[li. Sampling and Analytical Procedures
The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building
Inspector qualified by experience, education and training in the recognition of potential ACM and
approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a
limited number of bulk-samples being collected within the residence.
The inspection, assessment and sampling were performed in accordance with Environmental Protection
Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of
concern and the collection and analysis of representative bulk-samples of suspect material.
Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not
broken into in order to lorate and quantify suspect ACM. It should be nated that additional ACM might be
located in these and other inaccessible areas.
Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of
each homogeneous area (HA), were collected according to the guidelines published as Environmental
Protection Agency(EPA) Final Rule: Title II of the To�cic Substances Control Act(TSCA), 15 USC,Sections
2b41 through 2654 and in compliance with 40 CFR� Part 763. Representative sampling is based on the
following criteria:
1. The distribution of the suspect material throughout the HA.
2. The suspect material's physical characteristics a�d application.
3. Random sampling patterns detetmined for each HA.
Suspect materials sampled and analyzed should be considered to be representative of materials in each
HA if they exhibit similar physical characteristics and the application of the sampled material can be
correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the
EPA's Me hod for the Determination nf shactns in Rvlk RuildlTl,q MQtprinlc (EPA 600/R/116, July, 1993)
and the McCrone Research Institute's The Asbestos Particle AL1as as methods references. Analysis of the
bulk-samples was performed on the"date reported,"as listed in the bulk-sample analysis report.
3
N. Notes on Report Format
Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were
divided into three classifications:
1. Surfacing Mater�al: sprayed or troweled onto structural building member.
Z. Thermal System Insulation(TSI):any type of pipe,boiler,tank,or duct insutation.
3. Miscellaneovs Material: other suspect materials, ftoor tile, sheet vinyl/tinoleum, ceiling tiles,
insulation,and finishing materials.
Condition assessments were performed by the accredited inspector at the time of inspection. Condition
assessments are listed in the following section. Ratings of "good," "damaged," and "significandy
damaged"are meant to indicate the overall condition of the material.
A material in "good" condition has no visible damage or deterioration, or showing only very limited
damage or deterioration.
A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered,
water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the
damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or
debris similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence. A material in "significantly damaged" condition has one or more of the following
characteristics:
The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized).
One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or
showing adhesive failure.
Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris
similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence.
Response-action recommendations for asbestos-containing HAs are listed in the section VII.
Recommendations may be for more than one HA, if materials are alike. Recommendations are either
"general" or "immediate." An immediate recommendation indicates the presence of asbestos greater
than 1%within the bulk-sample, or a bulk-sample in the same HA,and should be addressed accordingly.
A general recommendadon indicates asbestos does not exist greater than 1%within the bulk-sample, or
all bulk-samples in the same HA, and no further abatement activities are required for removal of the
material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for
asbestos greater than 1%unless it is analyzed by the point-count method to be less than 1%.
V. Inspector Comments
No asbestos-containing material (ACM) was identified during the bulk-sampling conducted at 1160A
Casolar Del Norte Drive in Vail, Colorado. A total of three (3) bulk-samples were collected from drywall
in the above-referenced residence. All three (3) bulk-samples tested negative for asbestos.
4
VI. Homogeneous Area Descriptions
The following section contains sampled HA descriptions and sample locations. Percent-asbestos content
for each sample indicated can vary depending on sample locations, homogeneity of the materials, and
type of application. The following samples were collected from the single family residence at 1160A
Casolar Del Norte Drive in Vail, Colorado, on February 8, 2011. The quandties are approximations and
are subject to field verification:
i � , • • � ' i t � � • � ' i
Sample#: DW-01 Sample#:DW-02
Sample Description: Drywall&Texture Sample Description: Drywall&Te�cture
Sample Location: Garage wall drywall Sample Location: Garage wall drywall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: >200 ftz Material Quantity: >200 ft2
Material Condition: Good Material Condition: Good
Layers-Asbestos Content: Layers-Asbestos Cantent:
White/brown drywall-ND White paint w/white compound-ND
Beige paint w/white texture-ND Beige paint w/white texture-ND
White brown d all-ND
Recommendations: GENERAL-See Section Vll Recommendations: GENERAL-See Section VII
s E � ° � ; - ° �
Sample#:DW-03
Sample Description: Drywall&Texture
Sample Location: Garage wall drywall
Material Classification: Surfacing Material
Material Quantity: >200 ftz
Material Conditron: Good
Layers-Asbestos Content:
Bei e aint w white texture-ND
Recommendattons: GENERAL-See Section Vll
vit. Recommendations
GENERAL:
The laboratory results of the potential ACM sampled at 1160A Casolar Del Norte Drive in Vail, Colorado,
indicate that all three (3) bulk-samples of drywall collected were reported as negative for asbestos.
5
Therefore, no professional abatement activides are recommended to remove the above-referenced
material.
.
APPENDIX A
CERTIFICATION
,_ _�__ - - .. . - -- -_
�., .t� .t Z .�� �.ar � � `#
�. 3` � t''�,��'1 � �l ,�,e r��7�.�� �ti¢ 3"4 a�¢} ahi��"..�M,��y�;�.� r�� z�� !�r C `-�.
� � �1►,A" �'w',i�`�. _'aM!'"�� '�,,1�'`'.4 �V► ,e". �..� ��.� r;��
. .
�}► �_,
. _ .. .a _:- - —
�.�.,,.,_. _ £ j -.
r t � -ic
� ,��^
��:�` STATE �F COLORADO :�;:�°
�� ,� �.=.
�- � _
� :�� AsB�sros � �-
�� , .� ,
t= �` CERT1FtCATtON* l'' ��
z�:
f :�; �
. ,. , �
"'�-"_ �'s Cutvradu I)Cj731lIilCOI UI NUE)Ill'HC:tIIIl � � ��
' �� and Em•ir�r�ment s y- �
{���; .4ir Pollution Control Division
,� r ��
}t. t;.:
�s �. � ._
"'�,*.� This Certitie�that -"
��-� �f_ Brandon Sinkbeil i ��'
, ,F. � -=-
}'-- �i' Ccrtificatioo No: 134�i2 �'
i�..
S- S
i�f:ii��.. �'�; ��1:: �
..« �° � . ., N
�-�,�4t' has met the requirements of 25-7-507,C�.R.S.and:1ir()uality('cxitrul �` �s�
�'��� ('ommissioR Regulation No.8,Part B.and is hereby certifiad hy�he °� : �
< <_?�`:: �i,, statc of('oloradu in thc tollu�ving d�kirlinr- ��:;_'�`
.�a _ �3 �.
ib ' �° ��� �
r,��r; Buiiding Inspector� E �
r �,, ,�
� ,u;:,r
� �'"'-�•
; i��ucd: -�ibaato ���=
� r �
' E�pir�y on: i/1(�2011
� r' , ',
/
2..�" �--X�����1 j't � � j �~ ':
� C. r
� �����
;? '�j'1`~ , � °�
�. � z
1 :��'
s� !�_. -rM�..�rnj:an;,wl:O.nlc.:rr ih�y..v...ww./.rr.nwr Di.:.si.nypFr.avl r�r..in�;�wrrr .. l..y��' .t
� r.ttrlf+vnww ia rir dGc`IpHw.�y�mhN�bs�r
Y . � p� r�'�..
� � ,
/
�y� -�-�: ..`N �
S' -� 5»«�':-_' ,, � �r. � i.�i� �,' .-'j �'
.T'�� �. a�11 �!+ .-.l.F�.....����---n�Y �[ lt.�...��iMa �I%�n .��".i-°,e .
BS.�a+.`�a�."'..,..�..:,.:y.a,.�Y:,i.-ct}yy�.-e•=y-., --`•.o•�y-,, •�:;r,,
APPENDIX B
LABORATORY ANALYSI5
7
REI LAB ��s�rvnirs Environm�ntal /nc.
�
February 11,2011 Laboratory Code: RES
Subcontrad Number: NA
Laboratory Report:
Project�t/P.O.#
Projed Desc�tion:
Srandon Sinkbeil
DS Consulting, tnc.
5366 Flatrodc Ct.
Morrison CO 80465
Dear Customer,
RES 207478-1 R
None Given
1160A Casolar Del Norte
Dr.,Vatl,CO 81657
Reservoirs Environmental, Inc. is an analytical laboratory acc�dited for the analysis of Industrial Hygiene
and Environmental matrices by the Natiaral Voluntary Lab�atory Accreditation Program (NVLAP), Lab
Code 101896-0 for Transmission Electron Mic.�oscopy (TEM) and Pdarized Light Microscopy (PLM)
analysis and the American Industrial Hygiene Association(AIHA), L.a�b ID 101533-Accxeditation Certificate
#480 for Phase Cor�ast Microscopy (PCM) analysis. This laboratory is curret�tiy proficient in both
Proficiency Testing and PAT programs respectively.
Reservoirs Environmental, Inc. has analyzed tfie fdlowing samples for asbestos content as per your
request. The analysis has been completed in general acxordance with the appropriate methodology as
stated in the attached analysis table.The results have been submitted to your office.
RES 207479-1 R is the jab number assigned to this study. This report is considered highly confidential
and the sole property of the customer. Reservoirs Environmental, Inc.wi{I not discuss any part of this study
with personnel other than those of the dienL The resuits descxibed in tfiis report only apply to the samples
analyzed.This report must not be used to daim endorsement of produds or analytical resuiks by NVLAP or
any agency of the U.S. Govemment. This report shall not be reproduced exc�pt in full, without written
approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer
storage is requested.If ya�have any questions about this report,please feel free to ca� 303-964-1986.
Sincerely,
�-a-Z-.,� _� -���! �-. '
Jeanne Spencer Orr
President
, ��u-ff-_ , 1J1-���--_
Analyst(s):
Paul D.LoSca{zo Wenlong Liu
Michael Scales Rich Wegrzyn
Mita Grigg Robert R.Workman Jr.
Bethany Nichols
P:303-964-1986 5601 Logan Street,Suite 100 Denver,CO 80216
F:303-477-4275
Page 1 of 2
1-866-RESI-ENV
www.reilab.com
. �
�nP�n coae�o�esso
Tori�a�y�so.oi�
TABLE PLM BULK ANALYSiS,PERGENTAGE COMPOSRION SY VOLU1rE
RES Job Number.
Client:
Client Project Number/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Tumaround:
Date Malyzed:
F�S 2074T9-1R
DS Coosulting,lnc.
None Givett
1160A Casolar Del Norte Dr.,Vail,CO 81657
Felxuary 8,2011
PUII,Short Report
2 Hour
February'11,20�1
Page 2 of 2
ent � Asbestos ontent on on
Sample ID Number A Sub Asbesto Fibrou
Number Y Physical Part Fibrous Component
E Desniption (X) s (°�
R E�ts 96
DW01 EM 695928 A V4�ehxoNm drywall 40 50 50
B Beige paint w/white te�Qure 60 ND 0 100
DW02 EM 695929 A White pairrt w/white c�xnpound 10 ND 0 100
B Beige paint w/white texture 45 ND 0 100
C WixteJbrown drywaN 45 50 5Q
DW03 EM 695930 A Beige paint w/white te�mre 100 0 100
N!l-Nonc I)ctocicd
1R=Tnu.<l`F�YwW Fstim�
TrrnrAcaTrrnxilitc-Acriru�}itc
Note:FMI�wly�is by 7'GIN ic rtc��(ur aganidly 6aood ma�l li.a floar tilcl
if PLM rcmlcc aic<1 k.
Data QA
� ��o. � Z
, � __---�
A�f� �� � �,� ��'� �,�,. Department,of Communi#y Development�
��,*� � �'��,��' �� �° � �'� ,�.��� � ` � .� 75 South Frontage Road
�-�; �h � �:- _� �.� '�� �{:� Vail, Colorac�o 81�65�`=�
�� -�---`� . �� �' , �� fTel. 970-479 2'���i.`�
�_.� �� - °�,- Web:R www va�lgov cor�n�°
,, :
�a i:� `�� �� °�q ���'` Develop�rient;Re�inr Coordma#ca�=�
-� �., , .� �
��
� �.._..� r���:�. `��� .. �� �� ;:'-: ��' '� , `,� �'''-� �+� "�� �`������'�
. �
.
j� � .
� -
..�����tr�� � ' . ��' . w- � ,�. -^�y-,
x.�' ,k'�` .
.. �..-.,.. . ., ., Y . ..
�. . �_.'�ta'.� . �. . _ ._.
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address: Project#: �����' ��v�,�
��v '� ``_`��c��� �z-� lV.;�`e� :1 ��-�l' l� ._ t� ao�
(Number) (Street) (Suite#) DRB#:
Building/Complex Name: l�� ��u' I/� , ��L '�z Building Permit#: '—
Lot#: Block# Subdivision:
Contractor Information
Business Name: ���� (J�V� I �v� �c�2%� Work Class: New( ) Addition ( x ) Alteration ( )
Business Address: �°x 3 S�g Type of Building:
City V�" � State: �-U Zip: ���%�g Single-Family O Duplex(x) Multi-Family O
Contact Name:
�vv�tc�� �;v r�.e� Commercial ( ) Other( )
Contact Phone: J I I ��IID � l3> Work Type: Interior O Exterior O Both (>C)
Contact E-Mail: b1�¢� ��� � ��� ����`� L ��''"�``�� �`"� Valuation of
Work Included Plans Included Work
Contractor Registration Number: ,� .
� Electrical (x)Yes ( )No (x)Yes ( )No '� �� �`
X Mechanical (x)Yes ( )No ( Y)Yes ( )No "" 3 5vo
Owner/Owner's Representative Signature(Required) Plumbing ( x)Yes ( )No ( )Yes (�[ )No �= �oc�o
BUI�C�IfI ��,UJG
Project Information n g ( %C)Yes ( )No (k)Yes ( )No �
Owner Name: /1��-'-� ��(� `"�e'l�
Value of all work being performed: $�_���J,�JQ�
Parcel • ��v� "' ("'[ � —'1�6� �.� (value based on IBC Section 109.3&IRC Section 108.3� �
r Parcel#,contact Eagle County Assessors O�ce at(970328-8640 or visit c�
www.eaglecounty.uslpatie) Electrical Square Footage �
Detailed Scope and Location of Work: �r��'� �c S��s� ��-� �`�O�1�" - ��'�o��5� ��"°� `���'�`�
3 liv.,� :�"�:��� �,.�� I�� J ������1� �, ��I�.�z� � ; ,�5 f-�-I1 vt��,.J �,1; ,do� �
a,�� ���ce�S�,, �, S; �, .1��%-���-
� ►� — f�i c� .� �0 5���c�
(use additional sheet if necessary) � � ' — �p�r] � �' , rJs
Q� � - OOO� � �3,75
For Office Use Only: Date Received: D � � � a `� �
Fee Paid: ��j I�� I� )AN �
Received From: r�LU�- (�ul� �u����F25 /N(" � z���
Cash Check # ��
CC: Visa / MC Last 4 CC # exp date: T���n,� ��` �,/,���
Auth # ----t��_. ___�.�, �,
01-Jan-ll
�
,_,,
06-02-2011 Inspection Request Reporting Page 6
_7:24 am Vail, �_� Of
Requested Inspect Date: Thursday,June 02 2011
Site Address: 1160 CASOLAR DE`L NORTE DR VAIL
UNIT A
A/P/D Information
Activity: B11-0007 Type: A-MF Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: Insp Area:
Owner: VAIL ASSOCIATES LLC
Contractor: BLUE DEVIL BUILDERS, INC. Phone: 317-260-0735
Description: DEMOLISH AND REUILD THREE LIVING ROOM WALLS, RELOCATE FIREPLACE, INSTALL NEW
WINDOWS AND NECESSARY SIDING/TRIM.
Reauested Inspectionls)
Item: 90 BLDG-Final Requested Time: 09:30 AM
Requestor: Phone:
Comments: 317-26 - 735
Assigned To: *"" Entered By: MHAEBERLE K
Action: Time Exp:
Item. 534 PLAN -FINAL C/O Requested Time: 08:00 AM
Requestor: Phone:
Com ments: 317-260-0735
Assigned To: BGIBSON Entered By: MHAEBERLE K
Action: Time Exp:
� �
� ����
��
Inspection Historv
Item: 10 BLDG-FOOTING
04/12/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION
Comment:
Item: 20 BLDG-Foundation/Steel
04/12/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION
Comment:
Item: 410 Special Inspect-progress rept
Item: 30 BLDG-Frammg *Approved*`
05/06/11 Ins�pector: JRM Action: AP APPROVED
Comment: U VALUES CHECKED AND APPROVED .26
Item: 50 BLDG-Insulation "*A�pproved•*
05/06/11 Inspector: JRM Action: PI PARTIAL INSPECTION
Comment: CEILING ONLY R50
05/12/11 Inspector: JRM Action: AP APPROVED
Comment:
Item: 60 BLDG-Sheetrock Nail **Approved""
05/09/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION
Comment: Ceiling only
05/11/11 Inspector: sgremmer Action: AP APPROVED
Comment:
05/19/11 Inspector: JRM Action: AP APPROVED
Comment:
Item: 70 BLDG-Misc.
Item: 420 S ecial Inspect-final rept
Item: 90 BL�G-Final
Item: 534 PLAN-FINAL C/O
REPT131 Run Id: 13122