HomeMy WebLinkAboutB11-0008NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MWNOF VAIL '
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
ADD /ALT SFR BUILD PERMIT Permit #: 1311 -0008
Project #: PRJ10 -0697
Job Address: 1151 SANDSTONE DR VAIL
Location......: EAST SIDE WALL, ABOVE DECK AND DECKS
Parcel No....: 210301414004
OWNER SCOTT, GEORGE C. & CYNTHIA H 01/31/2011
3018 S PENINSULA DR
DAYTON BEACH SHORES
FL 32118
APPLICANT ANKERHOLZ INCORPORATED 01/31/2011 Phone: 970 - 926 -1490
PO BOX 296
AVON
CO 81620
License: 819 -B
CONTRACTOR ANKERHOLZ INCORPORATED 01/31/2011 Phone: 970 - 926 -1490
PO BOX 296
AVON
CO 81620
License: 819 -B
Description:
WINDOW ADDITION
Occupancy: R3 Single Family Residence Valuation:
Type Construction:VB Total Sq Ft Added:
Status .. :
ISSUED
Applied ..:
01/31/2011
Issued ...:
02/28/2011
Expires ...:
08/27/2011
$14,110.00
0
.....>..,,..... x.......... x .................. ............................... FEE SUMMARY .....,......,,.........,...,._ ............... .....,.........,.............,.
Building Permit Fee ------ > $251.25 Will Cal Fee --------------------- > $5.00 Total Calculated Fees ------------- > $501.76
Plan Check--------------- - - - - -> $163.31 Use Tax Fee --------------------- > $82.20 Additional Fees------------------ - - - - -> $0.00
Add'I Plan Check Hours -> $0.00 Restuarant Plan Review - - - - -> $0.00 TOTAL PERMIT FEES -- ----------- > $501.76
Investigation------------ - - - - -> $0.00 Recreation Fee------------ - - - - -> $0.00
Payments -- ---------------------------- > $501.76
Total Calculated Fees--- - - - - -> $501.76 BALANCE DUE------------------ - - - - -> $0.00
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the informatior
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the ns zoning and subdivision codes, de review approved, International Building and Residential Codes and other ordinances of the Town
applicable ther o.
REQUESTS FOR INSPECT�QN SHALL BE MADE
8:00 AM - 4:Ob PM. / �
nature "wner or Contractor
Print Name
b l d —a It —co n st ru ct i o n_pe rm it_041908
HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
Date
APPROVALS
Permit #: 611 -0008 as of 02 -28 -2011 Status: ISSUED
Item: 05100 BUILDING DEPARTMENT
02/18/2011 jrm Action: AP
Item: 05110 ELECTRICAL REVIEW
02/18/2011 jrm Action: NA
Item: 05120 MECHANICAL REVIEW
02/18/2011 jrm Action: NA
Item: 05130 PLUMBING REVIEW
02/18/2011 jrm Action: NA
Item: 05400 PLANNING DEPARTMENT
02/25/2011 rfd Action: AP Applicant shall
paint railing to match neighbors railing.
Item: 05600 FIRE DEPARTMENT
02/09/2011 mvaughan Action: AP
See the Conditions section of this Document for any that may apply.
b Id_a It_co n st ru ct i o n_pe rm it_041908
Permit #: B11 -0008
CONDITIONS OF APPROVAL
as of 02 -28 -2011 Status: ISSUED
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Cond: 44
(BLDG 2009): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION
R314 OF THE 2009 IRC, IF APPLICABLE UNLESS A MONITORED FIRE
ALARM SYSTEM IS REQUIRED.
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE
INSTALLED PER 2009 IRC R315
bld_a It—co nstruction_permit_041908
TOWN OF VAIL, COLORADO Statement
Statement Number: R110000134 Amount: $346.55 02/28/201109:29 AM
Payment Method: Check Init: RFD
Notation: 5237 ankerholz
-----------------------------------------------------------------------------
Permit No: Bll -0008 Type: ADD /ALT SFR BUILD PERMIT
Parcel No: 2103 - 014 - 1400 -4
Site Address: 1151 SANDSTONE DR VAIL
Location: EAST SIDE WALL, ABOVE DECK AND DECKS
Total Fees: $501.76
This Payment: $346.55 Total ALL Pmts: $501.76
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code
-------------- - - - - --
Description
Current Pmts
BP
00100003111100
------ ------------------ - - -- --
BUILDING PERMIT FEES
------ - - - - --
251.25
PF
00100003112300
PLAN CHECK FEES
8.10
UT
11000003106000
USE TAX 4%
82.20
WC
00100003112800
WILL CALL INSPECTION FEE
5.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADOCopy Reprinted on 01 -11 -2013 at 09:58:34 01/11/2013
Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: 8110000078 Amount: $155.21 01/31/201104:25 PM
Payment Method: Check Init: DR
Notation: CK# 1903 MATT
SAYRE
-----------------------------------------------------------------------------
Permit No: Bll -0008 Type: ADD /ALT SFR BUILD PERMIT
Parcel No: 2103 - 014 - 1400 -4
Site Address: 1151 SANDSTONE DR VAIL
Location: EAST SIDE WALL, ABOVE DECK AND DECKS
Total Fees: $501.76
This Payment: $155.21 Total ALL Pmts: $501.76
Balance: $0.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
PF 00100003112300 PLAN CHECK FEES 155.21
----------------------------------------------------------------------- - - - - --
Department of Community Development
75 South Frontage Road
Vail, Colorado 81657
Tel: 970 - 479 -2128
Web: www.vailgov.com
Development Review Coordinator
1 1
k -.
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address:
1151 Casolar Del Norte Dr E Unit
(Number) (Street) (Suite #)
Building /Complex Name:
Contractor Information
Business Name: Ankerholz Inc.
Business Address: PO BOX 296
City Avon State: CO Zip: 81620
Contact Name: Matt Sayre / Steve Ankerholz
Contact Phone: 970 - 949 -6341
Contact E -Mail: ankerholzinc @yahoo.com
Contractor Registration Number: 819 -B
X
Owner /Owner's Representative Signature (Required)
Project Information
Owner Name: Marshall I urley
Project #: P9 -3 10 — 0 (0 q//
DRB #: �j310o,55&to /nP_ ajDaG,35
Building Permit #: — 0 60 3
Lot #: Block # Subdivision:
Work Class: New ( ) Addition ( ) Alteration ( %/ )
Type of Building:
Single - Family ( ) Duplex (✓) Multi - Family ( )
Commercial ( ) Other( )
Work Type: Interior( ) Exterior (✓) Both( )
Work Included Plans Included
Electrical
( )Yes
(,/)No
( )Yes (
)No
Mechanical
( )Yes
(vONo
( )Yes (
)No
Plumbing
( )Yes
(voNo
( )Yes (
)No
Building
( ✓)Yes
( )No
(/)Yes (
)No
Valuation of
Work
14iin
Parcel #: 2103- 014 - 1400 -4
Value of all work being performed: $14110
(For Parcel #, contact Eagle County Assessors Office at (970 -328 -8640 or visit (value based on IBC Section 109.3 & I RC Section 108.3)
www.eaglecounty.us /patie) Electrical Square Footage
Detailed Scope and Location of Work: Replacement of Front decks. Rebuild of structure posted off of three helical piers
SEE PLANS. The installation of three Pella Windows to meet TOV requirements. Decking to be composite. Railing to
match neighbors as required by TOV DRB.
(use additional sheet if necessary)
For Office Use Only:
Fee Paid:
Received From:
Cash Check # _
CC: Visa / MC Last 4 CC #
Auth #
exp date:
Date Received:
D
JAN 3 1 2011
TOWN OF VAIL
01- Jan -11
State of Colorado
Asbestos Testing & Abatement Requirements
Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex-
posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly
for their requirements at the contact info listed below.
When is asbestos testing required?
ANY building projects disturbing more than these threshold levels of building materials require asbestos testing:
One- and Two - Family Dwellings: 32 square feet
All Others (commercial spaces, hotel rooms, etc): 160 square feet
Definition of a single - family dwelling: any dwelling unit that is used primarily for a single family, including
multi - family /condominium units, and fractional fee units.
Asbestos testing results must be provided with your application for a building permit.
Tests which identify POSITIVE results at more than 1% require abatement by a State - certified abatement contractor. The
air clearance letter or form must be submitted to the Town of Vail before the building permit will be issued.
Project Checklist
My project falls into the category checked below:
19 Will not disturb more than the threshold limits identified above.
❑ Tested negative, or at 1% or below (1 copies of test results included)
Tested positive at more than 1 %, requires abatement (1 copies of test results included)
Tips & Facts:
• Even recent construction projects may include asbestos - containing materials, so buildings of any age require testing.
• The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit
Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus,
much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce
of many asbestos - containing product categories was set aside and did not take effect." - CDPHE
Asbestos test results should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657.
Town of Vail Contact:
Fire Prevention Bureau
Vail Fire Department
75 S Frontage Rd
Fire— inspectors@vailgov.com
970 - 479 -2252
www.vailciov.com
State of Colorado Contact:
Colorado Department of Public Health
and Environment
Asbestos Compliance Assistance Group
303 - 692 -3158
asbestos@state.co.us
www.cdphe.state.co.us
01- Jan - I I
I �. C_warehd.rpt
V Date Printed: 1/19/2011
Warehouse Order Detail
DELIVER Y ITEMS PRINTED
Customer
Project / Ship -To
Order
Steve Ankerholz
Ankerholz /Turley
Order No.
042MT0453
Assembly Date
P.O. Box 296
1160 Casolar Drive
Customer No.
Conf. Del. Date
1/21/2011
AVON, CO 81620
VAIL, CO 81657
Order Date
12/28/2010
Need Date
1/14/2011
EAGLE
EAGLE
PreFinish Dale
Sales Rep. Code
042 -MT
Jamb Depth
Sales Rep. Name
Triebel, Michael
Bus: (970) 390 -6640
Bus: (970) 3906640
Window Store
Territory
04207
West
Dist. Order No.
Barcode:
042MT0453
111MY1EM111111
rComments: 12/28/2010 09:12:31 - POMS Branch Service Bldg Permit # B 10 -0361
Outside View
Item No. Qty. Description
Item# 010
Jamb Depth: 6-11/16"
Location:
/ R.O.: 25 -3/4 X 41 -3/4
Whse Loc PckgelD
LDC- 09 -B -2 042MT0453- 001001 A
PrefinishColor:
Comment:
Qty: 1 Architect, Casement Left, 25 X 41, Honeysuckle, 6- 11/16"
DA: N 1: 2541 Left Casement
Frame Size: 25 X 41
Architect Series
General Information: Not Specified, Standard, Clad, Pine
Exterior Color / Finish: Standard EnduraClad, Honeysuckle
Interior Color / Finish: Primed Interior
Glass: Insulated Low E Advanced High Altitude
Hardware Options: Standard Roto Operator, None, White
Screen: Full Screen, White, InView
Grille: None,
Wrapping Infonnation: Foldout Fins, Factory Applied, 6- 11/16" Standard
4 -sided Jamb Extension, Factory Applied, Perimeter Length = 132 ", Glazing
Pressure = 110.
Warehouse Order Detail - page 1 of 3
Warehouse Order Detail Report -- Customer: Steve Ankerholz Project: Ankerholz/Turley Order No • 042MT0453
Outside View Item No. Qty. Description
Comment:
Item# 015
Jamb Depth: 6- 11/16"
Location:
8.0.:47 -3/4 X 41 -3/4
Whse Loc PckgelD
LOC -8 -C -2 042MT0453- 002001A
PrefinishColor:
llem# 020
Jamb Depth: 6-11/1611
Location:
8.0.:25 -3/4 X 41 -3/4
Whse Loc PckI;e1D
LOC- 09 -B -2 042MT0453- 003001A
PrefinishColor:
Item# 025
Jamb Depth:
Qty: 1 Architect, Casement Fixed, 47 X 41, Honeysuckle, 6- 11/16"
DA: N 1: 4741 Fixed Casement
Frame Size: 47 X 41
Architect Series
General Information: Not Specified, Standard, Clad, Pine
Exterior Color / Finish: Standard EnduraClad, Honeysuckle
Interior Color / Finish: Primed Interior
Glass: Insulated Low E Advanced High Altitude
Grille: None,
Wrapping Information: Foldout Fins, Factory Applied, 6- 11/16" Standard
4 -sided Jamb Extension, Factory Applied, Perimeter Length = 176 ", Glazing
Pressure = 70.
Qty: I Architect, Casement Right, 25 X 41, Honeysuckle, 6- 11/16"
DA: N 1: 2541 Right Casement
Frame Size: 25 X 41
Architect Series
General Information: Not Specified, Standard, Clad, Pine
Exterior Color / Finish: Standard EnduraClad, Honeysuckle
Interior Color / Finish: Primed Interior
Glass: Insulated Low E Advanced High Altitude
Hardware Options: Standard Roto Operator, None, White
Screen: Full Screen, White, InView
Grille: None,
Qty: 1
Wrapping Information: Foldout Fins, Factory Applied, 6- 11/16" Standard
4 -sided Jamb Extension, Factory Applied, Perimeter Length = 132 ", Glazing
Pressure= 110.
Warehouse Order Detail - Page 2 of 3
'Warehouse Order Detail Report -- Customer: Steve Ankerholz Project: Ankerholz/Turley Order No.: 042MT0453
Outside View Item No. Qty. Description
Comment:
DA: N Small Delivery Zone 2 - Sm Delivei
Location:
R.O.: 0 X 0
Wise Loc PckgelD
PrcfinishColor:
Quality Like This Only Comes From Pella
Warehouse Order Detail - Page 3 of 3
ARCHITECT SERIES'
CASEMENT Architect Series'" Clad
Glazing Performance
Total Unit
° V o
Type of Glazing LL 2 1--i U
N >
Shaded Areas Meet ENERGY STAR'
Performance Criteria in Zones Shown
U.S. Canada'
Zone ER Zone
11/16" clear IG with 3 mm glass
with grilles- between- the -glass
with integral grilles
11/16" Advanced Low -E IG with argon with 3 mm glass
with grilles- between - the -glass
with integral grilles
11/16" NaturalSun Low -E IG with argon with 3 mm glass
with grilles- between - the -glass
with integral grilles
11/16" SunDefenseT' Low -E IG with argon with 3 mm glass
with grilles- between- the -glass
with integral grilles
11/16" SunDefense'' Dual Low -E IG with argon with 3 mm glass
with grilles- between - the -glass
with integral grilles
0.45
0.45
0.45
0.30
0.30
0.30
0.32
0.32
0.32
0.29
0.29
0.30
0.26
0.26
0.27
0.54
0.49
0.49
0.26
0.24
0.24
0.48
0.44
0.44
0.18
0.18
0.18
0.18
0.17
0.17
56
51
51
48
43
43
54
49
49
44
40
40
40
37
37
43
43
43
57
57
57
56
56
56
58
58
58
46
46
46
with grilles - between- the -glass
0.33
0.24
43
16
with integral grilles
0.34
0.24
43
54
11/16" NaturalSun Low -E HA IG with 3 mm glass
0.35
0.48
13
53
with grilles - between- the -glass
0.35
0.44
49
53
with integral grilles
0.36
13
49
53
11/16" SunDefenseT"' Low -E HA IG with 3 mm glass
0.33
0.20
44
54
with grilles - between- the -glass
18
0.18
40
54
with integral grilles
0.33
0.18
40
54
16
0.28
0.18
40
42
with grilles- between- the -glass
0.28
1
1
16
with integral grilles
0.29
0.17
37
42
28
25
25
14
14
13
18
17
16
11/16" Bronze Advanced Low -E IG w/ argon with 5 mm /3 mm Low -E
with grilles - between- the -glass
with integral grilles
11/16" Gray Advanced Low -E IG w/ argon with 5 mm /3 mm Low -E
with grilles - between- the -glass
with integral grilles
11/16" Green Advanced Low -E IG w/ argon with 5 mm /3 mm Low -E
with grilles- between- the -glass
with integral grilles
0.30
0.31
0.31
0.33
0.34
0.35
0.30
0.31
0.31
0.23
0.21
0.21
0.21
0.19
0.19
0.22
0.21
0.21
31
28
28
27
24
24
38
34
34
57
57
57
57
57
57
57
57
57
with grilles - between- the -glass
0.33
0.24
43
16
with integral grilles
0.34
0.24
43
54
11/16" NaturalSun Low -E HA IG with 3 mm glass
0.35
0.48
13
53
with grilles - between- the -glass
0.35
0.44
49
53
with integral grilles
0.36
13
49
53
11/16" SunDefenseT"' Low -E HA IG with 3 mm glass
0.33
0.20
44
54
with grilles - between- the -glass
0.33
0.18
40
54
with integral grilles
0.33
0.18
40
54
11/16" SunDefenseT" Dual Low -E HA IG with 3 mm glass
0.28
0.18
40
42
with grilles- between- the -glass
0.28
0.17
37
42
with integral grilles
0.29
0.17
37
42
15
13
13
11/16" Advanced Low -E HA IG with 3 mm glass
033
0.26
48
54
with grilles - between- the -glass
0.33
0.24
43
54
with integral grilles
0.34
0.24
43
54
11/16" NaturalSun Low -E HA IG with 3 mm glass
0.35
0.48
54
53
with grilles - between- the -glass
0.35
0.44
49
53
with integral grilles
0.36
0.44
49
53
11/16" SunDefenseT"' Low -E HA IG with 3 mm glass
0.33
0.20
44
54
with grilles - between- the -glass
0.33
0.18
40
54
with integral grilles
0.33
0.18
40
54
11/16" SunDefenseT" Dual Low -E HA IG with 3 mm glass
0.28
0.18
40
42
with grilles- between- the -glass
0.28
0.17
37
42
with integral grilles
0.29
0.17
37
42
(1) Glazing performance values are calculated based on NFRC 100.
(2) The values shown are based on Canada's updated ENERGY STAR® initiative that
will go into effect in October 2010.
For center -glass values, see the Product Performance section
-
R -Value = 1/U -Factor
SHGC = Solar Heat Gain Coefficient
VLT `Y = Visible Light Transmission
CR = Condensation Resistance
ER = Canadian Energy Rating
See the General Performance section for more detailed information.
Climate Zones
Rev. 09/30/2010 Pella 2010 Architectural Design Manual • Division 08 - Openings • Windows and Doors • www. Pella ADM.com 3 -6
ARCHITECT SERIES
CASEMENT Architect Series ", Clad - Fixed
Glazing Performance
Total Unit E]
Type of Glazing
° U o
V 0 Q
tL N j V
Shaded Areas Meet ENERGY STAR'
Performance Criteria in Zones Shown
U.S. Canada'
Zone ER Zone
11/16" clear IG with 3 mm glass
with grilles- between- the -glass
with integral grilles
11/16" Advanced Low -E IG with argon with 3 mm glass
with grilles - between- the -glass
with integral grilles
11/16" NaturalSun Low -E IG with argon with 3 mm glass
with grilles - between- the -glass
with integral grilles
11/16" SunDefensell Low -E IG with argon with 3 mm glass
with grilles - between- the -glass
with integral grilles
11/16" SunDefenser"^ Dual Low -E IG with argon with 3 mm glass
with grilles - between- the -glass
with integral grilles
0.46
0.46
0.46
0.28
0.28
0.29
0.30
0.30
0.31
0.27
0.27
0.28
0.24
0.24
0.24
0.62
0.56
0.56
0.30
0.27
0.27
0.56
0.50
0.50
0.22
0.20
0.20
0.21
0.19
0.19
65
58
58
56
50
50
63
56
56
51
46
46
47
42
42
42
42
42
57
57
57
55
55
55
57
57
57
45
45
45
with grilles - between- the -glass
0.35
0.27
49
19
with integral grilles
0.34
0.27
49
53
11/16" NaturalSun Low -E HA IG with 3 mm glass
0.34
0.56
16
52
with grilles - between- the -glass
034
0.50
56
52
with integral grilles
0.35
16
56
52
11/16" SunDefensell Low -E HA IG with 3 mm glass
0.33
0.23
51
54
with grilles - between- the -glass
22
0.21
46
54
with integral grilles
0.34
0.21
46
54
21
0.28
0.21
46
42
with grilles- between- the -glass
0.29
1
1
19
with integral grilles
0.28
0.19
41
42
35
31
30
19
1 g
17
22
21
21
11/16" Bronze Advanced Low -E w/ argon IG with 5 mm /3 mm Low -E
with grilles - between- the -glass
with integral grilles
11/16" Gray Advanced Low -E IG w/ argon with 5 mm /3 mm Low -E
with grilles- between- the -glass
with integral grilles
11/16" Green Advanced Low -E IG w/ argon with 5 mm /3 mm Low -E
with grilles - between- the -glass
with integral grilles
0.29
0.30
0.30
0.29
0.30
0.30
0.29
0.30
0.30
0.26
0.24
0.24
0.24
0.22
0.22
0.26
0.23
0.23
36
32
32
31
28
28
44
39
39
56
56
56
56
56
56
56
56
56
with grilles - between- the -glass
0.35
0.27
49
19
with integral grilles
0.34
0.27
49
53
11/16" NaturalSun Low -E HA IG with 3 mm glass
0.34
0.56
16
52
with grilles - between- the -glass
034
0.50
56
52
with integral grilles
0.35
16
56
52
11/16" SunDefensell Low -E HA IG with 3 mm glass
0.33
0.23
51
54
with grilles - between- the -glass
18
0.21
46
54
with integral grilles
0.34
0.21
46
54
15
0.28
0.21
46
42
with grilles- between- the -glass
0.29
0.19
41
15
with integral grilles
0.28
0.19
41
42
19
16
1 F,
11/16" Advanced Low -E HA IG with 3 mm glass
0.33
0.30
55
53
with grilles - between- the -glass
0.35
0.27
49
53
with integral grilles
0.34
0.27
49
53
11/16" NaturalSun Low -E HA IG with 3 mm glass
0.34
0.56
63
52
with grilles - between- the -glass
034
0.50
56
52
with integral grilles
0.35
0.50
56
52
11/16" SunDefensell Low -E HA IG with 3 mm glass
0.33
0.23
51
54
with grilles - between- the -glass
0.34
0.21
46
54
with integral grilles
0.34
0.21
46
54
11/16" SunDefensell Dual Low -E HA IG with 3 mm glass
0.28
0.21
46
42
with grilles- between- the -glass
0.29
0.19
41
42
with integral grilles
0.28
0.19
41
42
(1) Glazing performance values are calculated based on NFRC 100.
(2) The values shown are based on Canada's updated ENERGY STAR® initiative that
will go into effect in October 2010.
For center -glass values, see the Product Performance section.
R -Value = 1/U -Factor
SHGC = Solar Heat Gain Coefficient
VLT % = Visible Light Transmission
CR = Condensation Resistance
ER = Canadian Energy Rating
See the General Performance section for more detailed information
Climate Zones
Rev. 09/30/2010 Pella 2010 Architectural Design Manual • Division 08- Openings • Windows and Doors • wwwPel]aADM.com 3 -7
03 -13 -2012 Inspection Request Re orting Page 1
A. I., _._,. Vail C17 - City �Tla -
Requested Site Address: 1151 SANDSTONE DR,VAIL
EAST SIDE WALL, ABOVE DECK AND DECKS
A/P /D Information
Activity: 611 -0008 Type: A -BUILD
Const Type: Occupancy:
Owner: SCOTT, GEORGE C. & CYNTHIA H.
Contractor: ANKERHOLZ INCORPORATED
Description: WINDOW ADDITION
Reauested Inspections
Item: 90 BLDG -Final
Requestor:
Comments: vu�Assigned To: ON
Action:
4 Iq 1�7/
Inspection History
Item:
30 BLDG - Framing
Item:
50 BLDG - Insulation
Item:
60 BLDG - Sheetrock Nail
Item:
70 BLDG -Misc.
Item:
542 PLAN - FINAL
Item:
90 BLDG -Final
Time Exp:
Sub Type: ADUP Status: ISSUED
(Us - VB Insp Area:
onto: 970 - 926 -1490 ?0 32
Requested Time: 11:00 AM
Phone:
Entered By: MHAEBERLE K
REPT131 Run Id: 14232