Loading...
HomeMy WebLinkAboutA11-0003TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A11 -0003 Job Address: 5020 MAIN GORE PL VAIL Status ...: ISSUED Location.....: UNIT M -3 Applied..: 02/01/2011 Parcel No...: 210112432003 Issued. .. 02/03/2011 Project No Expires. .: 08/02/2011 OWNER ROSEN, REUVEN 02/01/2011 $0.00 Total Permit Fee--- - - - - -> 5253 E BAYAUD AVE DENVER $0.00 Payments ------------------ > CO 80222 APPLICANT THUL ELECTRONIC SYSTEMS 02/01/2011 Phone: 970 - 949 -4638 BALANCE DUE--- - - - - -> P O BOX 534 ************************************************************************************************************** * * AVON Approvals: CO 81620 License: 112 -S Item: 05600 FIRE DEPARTMENT CONTRACTOR THUL ELECTRONIC SYSTEMS 02/01/2011 Phone: 970 - 949 -4638 P O BOX 534 02/03/2011 mvaughan AVON CO 81620 License: 112 -S Desciption: NEW FIRE ALARM SYSTEM FOR A TOWNHOUSE. Valuation: $2,200.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Electrical --------- > $0.00 Total Calculated Fees - -> $370.50 DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00 Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $370.50 Will Call --------- > $0.00 Payments ------------------ > $370.50 TOTAL FEES --> $370.50 BALANCE DUE--- - - - - -> $0.00 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Approvals: Item: 05600 FIRE DEPARTMENT 02/03/2011 mvaughan Action: AP CONDITIONS OF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCF, BV TELEPHOXE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. GNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADO Statement Statement Number: R110000086 Amount: $370.50 02/03/201112:28 PM Payment Method: Check Init: LC Notation: #17470 / THUL ELECTRONICS ----------------------------------------------------------------------------- Permit No: All -0003 Type: ALARM PERMIT Parcel No: 2101 -124- 3200 -3 Site Address: 5020 MAIN GORE PL VAIL Location: UNIT M -3 Total Fees: $370.50 This Payment: $370.50 Total ALL Pmts: $370.50 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 FIRE ALARM PERMIT FEES 82.50 PF 00100003112300 PLAN CHECK FEES 288.00 Community Development 75 South Frontage Road Vail, Colorado .81657 pol Tel: 970 - 479 -2128; Fax: 970 - 479 -2452 Web: www.vailgov.Cq& lw FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: 5020 MAIN GORE PLACE (Number) (Street) Building /Complex Name: #M3 (Suite #) Office Use: Project #: (2 07 gS Building Permit #: j) I t'� G y 0 Alarm Permit #: 000 a Lot #: Block # Subdivision: Contractor Information: Company: Thul Electronics Company Address: PO Box 534 City: Avon State: CO Contact Name: Ron Davidson Contact Phone: (970) 949 -4638 Detailed Description of Work: NEW FIRE ALARM Zip: 81620 SYSTEM FOR A TOWNHOUSE. SEE DRAWINGS FOR DETAILED SCOPE OF WORK. E -Mail ron @thulelectronics.com Town of Vail Contractor Registration No.: 112 -S Digiully signed by Deborah Shane, Deborah Shane, DN Cn= Deborah Shane,. a= Shaner Life Safety, 0u FVE,e­ D2011,02.01 l =aha rls®cam 1s ,c =US X ate: 0]36]14)7W Contractor Signature (required) Property Information Parcel #: 2101- 124 -32 -003 (For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Owner Name: ROSEN, REUVEN Complete Valuation for Fire Alarm Permit: Fire Alarm $: $2200 9 5 ��p (use additional sheet if necessary) Does a Fire Alarm Exist? Yes ( ) No (., ) Does a Sprinkler System Exist? Yes( ) No (� ) Work Class: New ( ) Addition ( ) Remodel ( ) Repair ( ) Retro -Fit ( v ) Other ( ) Type of Building: Single - Family ( ) Duplex Multi - Family ( ) Commercial ( ) Restaurant ( ) Other ( ) Date Received: FEB o 12011 OF VAIL 29- May -09 SYSTEM SENSOR 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a low -cost means for property protection against fire, and for non - life - safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: - Single- and dual- circuit models - Fixed temp and combination fixed- temp /rate -of -rise 135 °F or 194 °F ratings. Plain housing for residential installations (Model 5601 P) Easy -to -use terminal screws A broad range of back box mounting options: - Single gang - 3.5" and 4 Octagonal - 4 square with square to round plaster ring • Reversible mounting bracket Agency Listings @ <F M > MEA LISTED APPROVED approved 4 '%.t Q r L Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual- circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature /rate -of -rise (FOR) activation. The FOR element of the fixed /ROR models is restorable to accommodate field- testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four - square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both Flush- and surface -mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed /rate -of -rise units are marked FX /ROR.The 5600 series also provides a post- activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Mechanical heat detector shall be a System Sensor 5600 series model number . fisted to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single- circuit or a dual - circuit type, normally open. The detector shall be rated for activation at either 135'F (57 - C) or 194'F (90'C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature /rate -of -rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15 °F (8.3 °C) per minute. The detector shall include a reversible mounting bracket for mounting to 3 -inch and 4 -inch octagonal, single gang, and 4 -inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14 -22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature /rate -of -rise models shall be restorable, to allow for field- testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/ Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 1007 (38'C) 5602, 5604, 5622, and 5624: 150°F (65.6 °Q Operating Humidity Range 5 to 95%RH non - condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 56011? 5603, 5621, and 5623: 135°F (57 °C) 5602, 5604, 5622, and 5624:1947 (90 °C) Weight 6 oz. (170 grams) Rate -of -Rise Threshold 15 °F (8.3 °q rise per minute (models 5601 P, 5602, 5621, and 5622 only) Mounting 3 -inch octagonal back box 4 -inch octagonal back box Single gang back box 4 -inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6- 125VAC / 3A 6 -28VDC / 1 A 125VDC / 03A 250VDC / 0.1 A Input Terminals 14 -22 AWG %r �\ �• /j - \k M (D u 0 5601P 5602,5622 5603,5623 5604,5624 5621 Ordering Information 5601 P Single None 135 °F (57 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194 °F (90 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135 °F (57 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194 °F (90 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135 °F (57'C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194 °F (90 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135 ° (57 °C) Fixed T empe r ature 25 f eet x 25 feet ( x 7.62 5624 'NOTE: Refer Dual to NFPA72 Lettering guidelines for spacing 194 °F (90 °C) Fixed Temperature reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) SYS 0x105 system Senuu TEM 3825 Ohio Avenue • St. Charles, IL 60174 Pmdwspeoacanomsugent.0h ngewmhosenot M.,ysremsmeorcom SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 ­mtpMt,ct'nr� ,�'uft9mewt�tve�ofm;sdalasleeL A05- 0351002.11/06.01676 y � L H I N W C 0 G L N �L Z M r � y T C O =• a N o J O M c N j C O m J N cv c ate+ vOiv C p O •� O U 'j w C O Y C y N m U Q� y pJ 7 C5 3 V' J 0-0 C E c � O CD E Q O p uj O c fl. O Y O 0 p C V O O U T p C w N a > W m N «+ d C ��. d > x N d U E O +•+ •— o f Q U w z vii Q1 a_+ 0 0 a N O O U LI) O = Z tp O 0- C 'O a cv O d a V) C O '= Q a O O Q a O p O C C d c 7 Q N t p U cv C O �, a+ O ul Z Y C U O iy O '� y C cm w Q L y y y y o C O _ - U W M d o f y Q. -Z N a N O a s m •O V) f0 — a0 C to 7 � CO w- N U � a me 3 CL �E C m V) C:) c N.° :3 c ,o CLo o CD V m N C C O :m E O O 0 0a c t 3 O O cp ., p L4 E J ++ a ' y N y _a O m > Q p m K .� a � C co m C O v r V c0 j E Uv v a� -E O cE O. evy� p� c m U Z O dc m Rte, m y ,`°, rn = V O v Y d rn ,� o Q LLB a�i O L C c O> O 7 V w 0 -� O O Co O L y v> O O O U w a J L6 J ti L6 2 0 u f w 0 Q `J 3 V O V m L �N L N O N t U 3 N ca cn m U N O7 . C d fA E co C U U C C O U L O U- Q O O O CL K O a E O U Q ca r r.+ OJ d cv N d 0 �® N co J (n Y .) �W� m N 2 Honeywell 5192S D/5192S DT V -PLEX® SMOKE DETECTOR • ''fii The Honeywell 5192 Series low profile, addressable V -Plex smoke detectors deliver state -of- the -art features and benefits in a cost - effective package. These detectors are designed to provide open area coverage and are compatible with Honeywell's VISTA controls supporting V -Plex technology. An LED on the detector will blink periodically during normal conditions, remain on steady during alarm and cease to pulse if the chamber is out of acceptable sensitivity range. An extremely powerful feature available within the 5192 Series is the Automatic Maintenance Alert/Reporting capability — a feature normally found in today's high end analog addressable systems. The detectors continually monitor their own sensitivity levels in addition to the basic normal and alarm conditions. These HIGH and LOW SENSITIVITY signals are communicated back to the FEATURES • Low profile design control, via the V -Plex addressable loop, to indicate locally and at the central station that the detector may not be able to detect smoke or may false alarm. This feature works with VISTA -32FB, 12813P, 128FBP, 250BP, 250FBP, 40, 50P, 100 -24 and FAP FA1600C, FA1660C and FA1700C. More important is the cost saving associated with Automatic Maintenance Reporting. The feature is an approved alternate to NFPA 72 field sensitivity calibration testing that require external test meters. This eliminates the need to schedule inspections to determine detector sensitivity/viability. Another important benefit of these V -Plex (addressable) smoke detectors is their ability to operate on existing wiring. There is no need to run special twisted pair, data grade or shielded wires, providing you with the right choice for all your retrofit applications. That equates to cost savings in time and materials! • Available with integral heat sensor • Lines on existing or conventional wiring • V -Plex addressable loop device • Automatic maintenance reporting APPLICATIONS • Simple 2 wire installation • DIP switch or serial number programmable The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V -Plex addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications. They are suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or professional office suites and in factory and warehouse environments. 5192S D/5192S DT V- PLEXTIM SMOKE DETECTOR SPECIFICATIONS Installation The 5192 Series smoke detectors are supplied with a convenient mounting bracket that allows the detector to be mounted to a variety of electrical junction boxes. A removable terminal block, that accepts 14 to 22 gauge wire to provide easy wiring connections. The detectors are designed to meet all applicable requirements for UL Commercial and Residential Fire installations as well as NFPA 72 requirements when installed in compliance with the National Electric Code and approved/listed control panels. W o z Q — F a. J rn J 0 JF (n « Q O - w° cr W DIP U) m Q SWITCH REMOVABLE F rn a TERMINAL BLOCK 0 0 diagram for 5192SD /SDT amok• detector Wrin9 Compatibility Serial number addressing is supported on VISTA -32FB, 1286P, 128FBP, 250BP, 250FBP, 100 -24 and FAP FA1600C, FA1660C and FA1700C controls. (Refer to control panel and smoke detector installation instructions for details.) Automatic Maintenance Reporting Compatibility The automatic maintenance feature is compatible with the following control panels: - VISTA -32FB - VISTA -128BP - VISTA- 128FBP - VISTA -250BP - VISTA- 250FBP - FA1600C - FA1660C - FA1700C The automatic maintenance may be disabled for all other controls that do not support this feature. Refer to control panel and smoke detector Installation Instructions for details. Electrical: Mechanical: • Diameter: 5.5 inches (140mm) (including mounting bracket) • Height: 1.7 inches (43mm) (including mounting bracket) • Weight: 5.3 ounces (150 grams) Environmental: • Installation temperature range: 32° to 100 °F (0° to 38 °C) • Installation humidity range: 10% to 93% RH, non - condensing • Heat sensor (5192SDT only): 135 °F fixed temperature electronic thermistor • EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - IEC EMC Directive Agency Listings • UL268 Commercial System Smoke Detector These smoke detectors are compatible with all VISTA control panels that support V -Plex (addressable) polling loop technology. The detectors support DIP switch or serial number addressing. DIP switch configuration are compatible with 5140XM, VISTA -40, and VISTA -50P controls. ORDERING • System voltage range: 7 -14 V Standby current (maximum ® 12V): - LED off: 1.2mA - LED on: 2.8mA • Meets UL 217 Requirements for Residential 5192SD Addressable Photoelectric Smoke Detector 5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor For more information: www.honeywell.com /security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 u5192/D May 2009 www.honeywell.com 0 2009 Honeywell International Inc. Honeywell ADEMCD 6139 An ADEMCO Group Company English Display Keypad The 6139 is an attractive, easy to use keypad that takes the guess work out of operating your security system. This console is designed in white to blend in with most surroundings. You can ' use it with the door closed to hide the keys, or remove the door completely to reveal them. New designer styled keypad with a 32 character custom English display and removable door. Everything in plain English A sophisticated and versatile keypad, the 6139 has a large, two line, 32 character, backlit cus- tomized English language display that indicates warnings and zone messages - there are no confusing blinking lights. An easy -to -use information center This smartly- styled console is the system's information center, providing the status of your security system at- a- glance, with all information clearly displayed in a bright, extra large liquid crystal display (LCD) window. Arranged in a telephone touchpad configuration, the keypad is easy to understand and operate. Keys are backlit to make nighttime operation possible. Customized to meet your needs and preferences Your system is programmed to your specific needs. Each protection zone is custom -pro- grammed into the control by your alarm installer and is identified by name. You are instantly aware of the status of your security system. Depending on your system, different emergency situations can signal a 24 -hour central station in case of a fire, police, or personal problem. Built -in self -help A self -help feature (on select controls) reviews the basic system functions and operation, dis- playing them in the console window; especially helpful to new users. It is activated by simply pressing any desired function key for five seconds. Keypad features: • New attractively designed white keypad with removable door • New easy -touch plastic white keys that are backlit for easy visibility • Large type that can display 2 lines of English text • Separate keys for emergencies • Built -in sounder - makes audible "beeps" for entry/exit delays, system status and other alarm conditions Ordering Information ♦ All protection zones and system events are displayed in simple English words Part No. Description ♦ User - friendly - all system functions are clearly marked on the touch pad. Operation is sim- 6139 Keypad plified by using a uniform "security code + command" entry to perform any desired function 165 Eileen Way, Syosset, New York 11791 • Copyright © 1997 Pittway Corporation ADEMCD ADEMCO is an IS09001 Registered Company G R O U P L/6139/D Rev. 1/99 SYSTEM SENSOR Mini -Horns The SpectrAlert' Advance series of mini -horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. 7 _ W AIL i o m S s t e m S e n s o r Fe atures 12 and 24V operation High and low volume settings -Temporal and non - temporal tones Mounts to single gang back box Compatible with MDL sync module Mechanically and electrically compatible with PA400 series Mini - Alert" sounders Ag ency Li UL r F M MEA .C. LISTED APPROVED approved W, I I i.. ,. The MHR and MHW mini -horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini -horns offer high and low volume settings, and temporal or non - temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini -horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. i y 7 _ W AIL i o m S s t e m S e n s o r Fe atures 12 and 24V operation High and low volume settings -Temporal and non - temporal tones Mounts to single gang back box Compatible with MDL sync module Mechanically and electrically compatible with PA400 series Mini - Alert" sounders Ag ency Li UL r F M MEA .C. LISTED APPROVED approved W, I I i.. ,. The MHR and MHW mini -horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini -horns offer high and low volume settings, and temporal or non - temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini -horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. SpectrAlert' Advance Mini -Horn Specifications Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini - horn shall be listed to Underwriter's Laboratories Standard U1 464 for fire protective signaling systems. Mini -horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9 x.45 D Weight 2.67 oz. Operating Temperature Range 32 °F to 120 °F (0 °C to 49 °C) Mounting Surface: single -gang back box Flush: 4 - x 4 - BBD deep back box (2'/4 - deep) Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC /FWR or regulated 24DC/FWR Operating Voltage 8 -33 Operating Voltage with MDL 9 -33 UL Sound Output and Current Draw Data Switch Setting Pattern Output Level 8 -17.5 VDC 8 -17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16 -33 VFWR I Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- temporal High 72 71 75 74 80 79 4 Sounder Current Non - temporal Low Draw (mA RMS) 70 69 73 72 78 77 Switch Position Sound Pattern Volume 8 -17.5 Volts DC FWR 16 -33 Volts DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non - temporal High 22 17 29 25 4 Non- temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini -Horn, Red MHW Mini -Hor White SYSTEM 02007 system Sen.— TEM 3825 Ohio Avenue - St. Charles, IL 60174 vomMw�n�t_$Ubjedt,margew «rt�e.vAm� ,for SENSOR Phone: 800- SENSOR2 - Fax: 630 - 377 - 6495 ` ae"t rxM ,ct"'fo,,,,a"a',­iUdr CnOfftda`aS»"` A05-0414- 000.1/07.01743 Rechargeable Sealed Lead -Acid Battery PS -1270 12 Volt 7.0 Amp. H rs. Features: hlClgl =L PS-1270 F1 12 %0t 7 0 AMP W. • Absorbent Glass Mat (AGM) technology for superior performance. • Valve regulated, spill proof construction allows safe operation in any position. • Power /volume ratio yielding unrivaled energy density. • Rugged plastic case and cover • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. • U.L. recognized under file number MH 20845. oM PERFORMANCE SPECIFICATIONS Nominal Voltage ........................................................................................................................ ............................... 12 volts (6 cells in series) Nominal Capacity 20 hour rate (350mA to 10.50 volts) ....................................................................................................... ............................... 7.0 A.H. 10 hour rate (650mA to 10.50 volts) ....................................................................................................... ............................... 6.5 A.H. 5 hour rate (1.2A to 10.20 volts) ........................................................................................................... ............................... 6.0 A.H. 1 hour rate (4.5A to 9.00 volts) ............................................................................................................ ............................... 4.5 A.H. 15 min rate (14A to 9.00 volts) .............................................................................................................. ............................... 3.5 A.H. ApproximateWeight ..................................................................................................................... ............................... 5.70 pounds (2.59 kg) Energy Density (20 hour rate) ............................................................... ............................... 1.43 Watt- hours /cubic inch (87.3 Watt- hours /1) Specific Energy (20 hour rate) .................................................................. ............................... 14.7 Watt- hours /pound (32.4 Watt- hours /kg) Internal Resistance (Fully Charged Battery) .................................................................... ............................... 22 milliohms (approximately) Maximum Discharge Current ( < 7 Min.) ..................................................................................................... ............................... 21 amperes Maximum Short- Duration Discharge Current ( < 10 Sec.) ....................................................................... ............................... 70 amperes Terminal configurations ...................... ..........................Quick disconnect tabs, "F1 ": 0.187" x 0.032 ", mate with AMP. INC. FASTON "187" Quick disconnect tabs, "F2 ": 0.250" x 0.032 ", mate with AMP. INC. FASTON "250" Shelf Life — % of nominal capacity at 68° F (20° C) 1 Month .......................................................................................................................................................... ............................... 97% 3 Months ........................................................................................................................................................ ............................... 91% 6 Months ........................................................................................................................................................ ............................... 83% Operating Temperature Range Charge.................................................................................................................................... ............................... -4 °F ( -20 °C) to 122 °F (50 °C) Discharge............................................................................................................................... ............................... -4 °F ( -20 °C) to 140 °F (60 °C) Case.................................................................................................................................................................. ............................... ABS Plastic Ya. TECHNICAL DATA: Shelf Life and Storage 100 0 O M 80 c O 60 d d' w D 40 CL U 0 100 80 A m 60 U c 40 4 20 d 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) of less city fore sary er A of 3ch Life Characteristics in Stand -By Use Ambient Temperature 20'C (68'F) Float Charging Voltage 2.25 - 2.30 V /Cell 0 120 100 0 4' 80 U R o. U 60 C 40 C a 20 1 2 3 4 Years Life Characteristics in Cyclic Use 0 0 Charging is I necessary ui Discharge Depth 50% Discharge Depth 30% 1. Discharge Current 0.2C (Final Voltage 1.7V /Cell) 2. Charge Current: 0.1C - 4 3. Ambient Temperature: 20 °C to 25 °C (68 °F to 77 °F) Final Voltage 10.5V 10.2V 100% of cap is required. 9.60V �\ 9.OV 5°C ( 41 *F) Charging bf use is nece to help reco 20 ° C 0 8.10V full capacit' Charge may 40 °C 30 ° C 20 °C o restore full (104 ° F) (86 °F) 68 °F ( ) adly. Do i t t acity. es rf s state. U 0 100 80 A m 60 U c 40 4 20 d 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) of less city fore sary er A of 3ch Life Characteristics in Stand -By Use Ambient Temperature 20'C (68'F) Float Charging Voltage 2.25 - 2.30 V /Cell 0 120 100 0 4' 80 U R o. U 60 C 40 C a 20 1 2 3 4 Years Life Characteristics in Cyclic Use 0 0 200 400 600 800 1000 1200 Number of Cycles CHARGING Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (undercharge) reaches 14.40 to 14.70 volts at 68 (20 Hold at 14.40 to 14.70 volts until current drops to approximately 70mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "Float" or "Stand -By" Service: Hold battery across constant volt- age source of 13.50 to 13.80 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. NOTE: Due to the self- discharge characteristics of this type of bat- tery, it is imperative that they be charged after 6 -9 months of stor- age, otherwise permanent loss of capacity might occur as a result of sulfation. (V) 14.0 13.0 m 12.0 j 11.0 C 10.0 . y 9.0 I- 8.0 Discharge Characteristics PS -1270 W. MINES, 1110 =110 ■III ■1��11�'�! ""l ■Iii ■ ■��,� .._ �.� V •� A min hra Discharge Time � ��¢ 3 e III I IVIIVIiN�IIreIry A i ll MVq �I L. Discharge Time vs. Discharge Current 20 15 10 5 z 2 E E 1 d E 30 r U 10 5 Discharge Depth 100% Discharge Depth 50% Discharge Depth 30% 1. Discharge Current 0.2C (Final Voltage 1.7V /Cell) 2. Charge Current: 0.1C - 4 3. Ambient Temperature: 20 °C to 25 °C (68 °F to 77 °F) 200 400 600 800 1000 1200 Number of Cycles CHARGING Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (undercharge) reaches 14.40 to 14.70 volts at 68 (20 Hold at 14.40 to 14.70 volts until current drops to approximately 70mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "Float" or "Stand -By" Service: Hold battery across constant volt- age source of 13.50 to 13.80 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. NOTE: Due to the self- discharge characteristics of this type of bat- tery, it is imperative that they be charged after 6 -9 months of stor- age, otherwise permanent loss of capacity might occur as a result of sulfation. (V) 14.0 13.0 m 12.0 j 11.0 C 10.0 . y 9.0 I- 8.0 Discharge Characteristics PS -1270 W. MINES, 1110 =110 ■III ■1��11�'�! ""l ■Iii ■ ■��,� .._ �.� V •� A min hra Discharge Time � ��¢ 3 e III I IVIIVIiN�IIreIry A i ll MVq �I L. Discharge Time vs. Discharge Current 20 15 10 5 z 2 E E 1 d E 30 r U 10 5 (104 ° F) (68 ° F) ( ° F) 0.35 0.7 1.4 3.5 7 14 Discharge Current (A) Physical Dimensions: in. (mm) Terminals "F1° FAS 0.18]' aisconnea x 0 032' ' ® qui k labs. ® °' °F2" F ASTON 0.250' 1 0.032' ouiv<aiscunnea labs. I� 595(151 -� s,a�ae Raba Gallery reeabia Paf!/E/P SON /C MODEL PS -1270 F1 _n•+ 11 Vdl ]OAmp H, �• Tolerances are +/. 0.04 in. ( +/• 1mm) and +/• 0.08 in. ( +/- 2mm) for height dimensions. All data subject to change without notice. POL�/ER SOA/ /C SALES & MARKETING ISO9OOI -2000 CUSTOMER SERVICE 3106 Spring Street 7550 Panasonic Way Redwood City, CA 94063 USA FM39170 San Diego, CA 92154 USA Tel: 650-364-5001 Fax: 650-366-3662 % Tel: 619.661 -2030 Fax: 619.661 -3648 national - sales @power- sonic.com www.power- sonic.com customer- service @power- sonic.com 1104 1% Final Voltage 10.5V 10.2V 9.60V �\ 9.OV 40 °C 20 ° C 0 8.10V (104 ° F) (68 ° F) ( ° F) 0.35 0.7 1.4 3.5 7 14 Discharge Current (A) Physical Dimensions: in. (mm) Terminals "F1° FAS 0.18]' aisconnea x 0 032' ' ® qui k labs. ® °' °F2" F ASTON 0.250' 1 0.032' ouiv<aiscunnea labs. I� 595(151 -� s,a�ae Raba Gallery reeabia Paf!/E/P SON /C MODEL PS -1270 F1 _n•+ 11 Vdl ]OAmp H, �• Tolerances are +/. 0.04 in. ( +/• 1mm) and +/• 0.08 in. ( +/- 2mm) for height dimensions. All data subject to change without notice. POL�/ER SOA/ /C SALES & MARKETING ISO9OOI -2000 CUSTOMER SERVICE 3106 Spring Street 7550 Panasonic Way Redwood City, CA 94063 USA FM39170 San Diego, CA 92154 USA Tel: 650-364-5001 Fax: 650-366-3662 % Tel: 619.661 -2030 Fax: 619.661 -3648 national - sales @power- sonic.com www.power- sonic.com customer- service @power- sonic.com 1104 1% Honeywell VISTA -50P CONTROL PANEL Honeywell's VISTA -50P Control Panel provides the flexibility of up to eight independent partitions with the economy of a single control. FEATURES Dependable features to meet your most demanding installations: • Nine hardwired zones standard • Expandable to 87 total zones • Eight partitions standard • 75 user codes work in all partitions • Seven authority levels • 224 event memory log /printer option • Four trigger outputs • 5800 Series wireless compatibility • Supports two -wire multiplex • Scheduling of events (real time clock) • Keypad macro features • Master console option for viewing all partitions at a glance • Common lobby logic • Fast downloading • Supports up to 16 relays and /or X -10 • Quick start programming • False alarm features • UL Commercial Burglary listed (VISTA- 50PUL) End users will appreciate the easy -to -use convenience and control features of the VISTA -50P: • Wireless remote controls (featuring single button system operation): — 5804 - Four -Button Wireless Key — 5804BD - Bidirectional Four -Button Wireless Key with system status feedback • Single or dual- button wireless personal panic: — 5802MN — 5802MN2 • Home control features activate lights, appliances, garage doors and numerous other devices • The VISTA Interactive Phone Module (VIP) gives the end -user control of their system from any touchtone phone. The 4286 VIP responds in English, with a vocabulary of over 100 words • Full English display keypads for clear understanding of system status and zone locations • Timed event applications: — Opens garage doors and turns on lights — Provides "lived -in look" while away from home — Ability to limit access to parts of the home at certain times VISTA -50P CONTROL PANEL SPECIFICATIONS Electrical • Aux power 12VDC, 750mA max • 16.5 VAC /40 VA transformer • Alarm output 12VDC, 1.7 Amps max • For UL installations, combined Aux and alarm output cannot exceed 750mA Output Control • Supports up to four relay boards (Part No. 4204) • Each board supports four relays for a total of 16 • Optional X -10 interface (Part No. 4300) may be used to control X -10 receiving devices • Each X -10 receiver address counts as one relay when computing total relays • Real time clock can be used for relay/X -10 control Zones • Nine hardwired zones • Selectable response on zone 9: 10MSec or 500MSec • Assignable to any partition • 14 zone types to choose from • Programmable swinger suppression Communications • Touchtone or pulse • Formats supported: ADEMCO Contact ID, ADEMCO 4 + 2 Express, ADEMCO low speed • 3 +1, 4 +1 and 4 +2 reporting • Reporting capabilities: Split, Dual, Split/Dual • Low battery reports 11.2- 11.6VDC • Expanded reporting • Up to four digit PABX codes supported • True dial tone detection • Double pole line seizure • AC loss and restoral reporting supported Supported Devices Hardwired Expansion Devices • 4208U Eight -Zone Expansion Module • Keypads — 6139 Custom English (required for programming) -100mA — 6128 Fixed English LCD - 30mA • Voice Module 4286 VIP -160mA • Two -Wire Smoke Detectors • Duct Detectors • Serial Printer • Polling Loop Devices • Key Switch Devices Wireless Receiver Systems • 5800 Series — 5881 ENL up to 8 zones -50mA — 5881 ENM up to 16 zones -50mA — 5881 ENH up to 26 zones -50mA • All Receivers Support: — Diversity reception with two antennea — Remote mounting for best location — Use of second receiver for maximum coverage or tough installations — Unique supervision and low battery indications by point Transmitters • 5800 Series — Three volt Duracell lithium batteries — One mile range — Tamper standard Agency Listings • UL Residential Fire and Burglary and CSFM • UL Commercial Burglary (VISTA- 50PUL) ORDERING VISTA -50P Control Panel Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com WIs50P /D September 2008 0 2008 Honeywell International Inc. Honeywell