Loading...
HomeMy WebLinkAboutA11-0004TOWN OF VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 OWNER VAIL FIRE DEPARTMENT I�[�7111�1�I11:If.��f�Tlib`�: �l��I.��1� ►�Z� : `����:��TI[I�T�IJ] ALARM PERMIT Job Address: 68 E MEADOW DR VAIL Location.....: iJNIT 602, VAIL VILLAGE INN Parcel No...: 210108254031 Project No : APPLICANT ��]�I�M:�.I�[i]:� VAIL VILLAGE INN INC 100 E MEADOW DR VAIL CO 81657 COMMERCIAL SPECIALISTS PO BOX 3913 EAGLE CO 81631 License: 161-5 COMMERCIAL SPECIALISTS PO BOX 3913 EAGLE CO 81631 License: 161-5 02/02/2011 OF WE 02/02/2011 OF WE 02/02/2011 Perm it #: A ] 1-0004 Status . . . : ISSUED Applied . . : 02/02/2011 Issued . . : 02/15/2011 Expires . .: 08/14/2011 Phone: (970) 328-1951 Phone: (970) 328-1951 Desciption: FIRE ALARM WORK FOR COMMERCIAL TENANT FINISH IN EXISTING BUILDING. (WOO RESTAURANT, AKA SUSHI OKAI). Valuation: $3,200.00 **+*�*�**�****s*�+*+*****��*��*►********+t**e****+**�**�+*�*+e***«*r FEE SUMMA R Y a***+*�*****s*+*»�*+*+�**+�**+�*++*****+�*�r*+**�**+�**** Electncal---------> $o . 00 Total Calculated Fees--> $4os . o0 DRB Fee---------> $o . oo Additional Fees----------> $o . o0 Investigation----> $o . oo Total Permit Fee--------> $408 . 00 Wiil Call---------> $o. oo Payments------------------> $408. o0 TOPAL FEES--> $408.00 BALANCE DUE--------> $0. 00 ..�.*�+�**++.*+*+***�.++s+�*+**��.��*...*.�...*.rs.�*r�*:r***•..�..++*►******�**e.****+.�.+�•******«*�**.*s*+*+****.*��+.*+�**.+*++*.+*.■.��� Approvals: Item: 05600 FIRE DEPARTMENT 02/14/2011 McGee Action: AP ..**...�+**++�•..*.*+.•..+«+*+#.+++:..+:.++++,+..++:+«:....*�+++..::*�*�**+++�+�����.�+�:+**�*+*+** «��.**.��+*+��+.�.+++.++�+�.++:*+:.�#++.# CONDITIONS OF APPROVAL *�*****»*�*�*********...**********��.*.�**�*���....****�.*******.*, **..�***.,�**.�*.*�.***.,.�.***�.*..�**...�...*.*.**.��.****.��**..�.*..*, * DECLARATIONS I hereby acknowledge that I have read this application, frlled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOUIjF�I�ADVANCE BY .: � � ,��✓ z' '�IGNATURE OF Q.� HONE AT 970-479-2252 FROM 8:00 AM - 5 PM. OR CONTRACTOR FOR HIMSELF AND OWNEF **************************************************************************************�**�** TOWN OF VAIL, COLORADO Statement ***************+***************************************************+*************�********+* Statement Number: R110000104 Amount: $408.00 02/15/201108:33 AM Payment Method: Check Init: SAB Notation: 11136-C.S.W.C. ----------------------------------------------------------------------------- Permit No: Al1-0004 Type: ALARM PERMIT Parcel No: 2101-082-5403-1 Site Address: 68 E MEADOW DR VAIL Location: UNIT 602, VAIL VILLAGE INN Total Fees: $408.00 This Payment: $408.00 Total ALL Pmts: $408.00 Balance: $0.00 ***************************************************************************+**+*+*********** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 FIRE ALARM PERMIT FEES 120.00 PF 00100003112300 PLAN CHECK FEES 288.00 �� `� ��+° "" ° , Department of Community Development; � � � � .;� �... :�� {> ��, �:� �`�, , `�� � , 75 South Frontage Road ,. � �, . � .; . . . ;. �°: .; `�� ,�=�,_ �� ''�,'ur� � �+• Vail,.Colorado 81657� °k w � � �� ��� . ����+� r � Fax�: 970 479 245�� i' , � �, ,���.: ��., �' n f '�,,��. - ` Web:� www.Vailgov cort� p ` �' �`� e e1o",mentReview,Co rd,nato���� �. � ,,`, - � �� ��p �� . � � i ;�, , • , � Q , s : .�„_ i .. m ., ��, y { , . , ., - - • .�. �' 4 �'��IE rw�., m�w ,.. �y� FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: 100 E. MEADOW DRIVE (Number) (Street) BuildinglComplex Name: VAIL VILLAGE INN Contractor Information: Company: CSWC Company Address: PO Box 3913 City: Eagle State: CO Contact Name: Tim Ward Contact Phone: 970-328-1951 E-Mail cswc.tim@centurytel.net 1 (Suite #) Office Use: Project #: �/� � f �— Q oi,o� � Building Permit #: � �� ' � �,a� Alarm Permit #: � � � — � (' � � Lot #: Block # Subdivision: Detailed Description of Work: Fire alarm work for Zip: 81631 commercial tenant finish in existing building. See Town of Vail Contractor Registration No.: 161-S Deborah �°���,�;°;,�.w�M i( Shaner o.�,e,�o,o�,.,,»a,� Contractor Signature (required) Property Information Parcel #: 2101-082-61-001 (For parcel #, contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Tenant Name: Owner Name: VAIL VILLAGE INN INC Complete Valuation for Fire Alarm Permit: Fire Alarm $: $3200 drawing set for detailed scope of work. (use additional sheet if necessary) Does a Fire Alarm Exist? Yes (+) No () Does a Sprinkler System Exist? Yes (+) No () Work Class: New ( ) Addition ( ) Remodel ( � ) Repair ( ) Retro-Fit ( ) Other ( ) Type of Building: Single-Family ( ) Duplex ( ) Multi-Family ( ) Commercial ( + ) Restaurant ( ) Other ( ) Date Received: �C��Q�I� D FEB 0 2 2011 TOWf� OF VAIL 29-May-09 FMM-1(A), FMM-101(A), FZM-1(A) & FDM-1(A) Monitor Modules with FlashScan� General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1(A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D(Class A) or Style B(Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1270 cm) D that super- vises a Style B(Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D(Class A) or Style B(Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B(Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan� (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM-1(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 — 159 on FlashScan loops; 01 — 99 on CLIP loops. • LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-i(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B) or Style D(Class DN-6720:C • H-220 �J NOTI FI E R�� by H o n eywe I I � " � "'.°1 � �I � ., ` �, . .. � ... � <� �,,, _� € ' ;��:�`� ..�,., � � ...,w - .,��,. d� �,.,�.,, ..,�,.�,...,�.a.�,,..,.o � .�. •��s�,*. �, •� � _ �� � ,�r� �..� -� �� � ^ � S �.� �� �i e � FMM-1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 NA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidlty range: 10% to 93% noncondensing. Dlmensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:C • 10/O6/2010 — Page 1 of 4 FMM-101(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immuniiy. • Tinned, stripped leads for ease of wiring. • Direct-dial entry of address: 01 — 159 on FlashScan loops; 01 — 99 on CLIP loops. �q 15 0 � ADDRESS 0 � 13 2 � 2 �� O 4 LOOP O� I4 � 109 8 7 ss 9 8 � 65 TENS ONES � � O J O U } � � m The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuiUdevice is wired as an NFPA Style B(Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 NA, 1 communication every 5 seconds, 47k EOL; 600 uA Max. (Communicating, IDC Shorted). Maximum IDC wiring res(stance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 uA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Page 2 of 4— DN-6720:C • 10/06/2010 Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1(A) Interface Module • Supports compatible two-wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 — 159 on FlashScan loops, 01 — 99 on CLIP loops. • LED flashes during normal operation; this is a programma- ble option. • LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D(Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D(class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polis from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIF/CATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 NA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM1(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style 8(Class 8) IDC circuits ONLY. Style D(Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPEC/FICATIONS Normal operatfng voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 NA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 NA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensfons: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses "26" and "2T'. NOTE: "Ones"addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and termina/s 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • ULC: S635 • FM Approved • CSFM:7300-0028:0219 • MEA:457-99-E • U.S. Coast Guard: — 161.002/23/3 (AFP-200: FMM-1/-101, FZM-1) — 161.002/42/1 (NFS-640: FMM-1/-101) Lloyd's Register: —03/60011/E1 (FMM-1/-101, FZM-1) — 94/60004/E2 (AFP-200: except FDM-1) — 02/60007 (NFS-640: FDM-1) FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: 'A"suf/ix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:C • 10/O6/2010 — Page 3 of 4 ISO 9001 BYiINE91NC 8 hUWIFACi1NIY6 QUAl1iY 51'STEMS FlashScan� and NOTIFIER� are registered trademarks and FireWatchTM' is a trademark of Honeywell Intemational Inc. m2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Pho�e: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6720:C • 10/06/2010 Made in Me U.S. A. NBG-12LX Addressable Manual Pull Station General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 Ib. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol loops. • Up to 159 NBG-12LX stations per loop on FlashScan� pro- tocol loops. • Dual-color LED blinks green to indicate normal on FlashS- can� systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VOC. • Maximum SLC loop current: 375 NA. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humldity: 10% to 93% (noncondensing) • For use indoors in a dry location �J DN-6726:C1 • H-240 NQTI FI E R" by H o n eywe I I The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4' (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 — 159 on FlashScan� systems, 1— 99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4' DN-6726:C1 • 8/i 6/10 — Page 1 of 2 (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-I/0: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate Agency Listings and Approvals In some cases, certain modules or applica6ons may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL / CUL Listed: S692 (listed for Canadian and non-Cana- dian applications) • MEA:67-02-E • CSFM:7150-0028:0199 • FDNY: COA #6038 (NFS2-640), COA #6058 (NFS2-3030) • BSMI: CI313066760047 • U.S. Coast Guard: 161.002/23/3 (AFP-200); 161.002/27/3 (AM-2020/AFP-1010; 161.002/42/1 (NFS-640) • Lloyd's Register: 02/6007 (NFS-640); 94/60004 (E2) (AFP-200); 03/60011 (E1); 07/60007 (NFS2-3030) • FM Approved Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Notifier� and FlashScar� are a registered trademarks of Honeywell IntemaUonal Inc. m22010 by Honeywell Internatlonal Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ��O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements ENiI�EfAINi i MANAFACnAINC All specifications are subject to change without notice. QUALITI SISTEMB MadeinmeU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6726:C1 • 8/16/10 FST-851 Series Intelligent Thermal (Heat) Detectors with FlashScan� General Notifier FST-851 Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations. FST-851 Series thermal detectors use an innovative thermistor sensing circuit to produce 135°F/ 57°C fixed-temperature (FST-851) and rate-of-rise thermal detection (FST-851 R) in a low-profile package. FST-851 H pro- vides fixed high-temperature detection at 190°F/88°C. These thermal detectors provide effective, intelligent property protec- tion in a variety of applications. FST-851 Series detectors are compatible with all Notifier intelligent Fire Alarm Control Pan- els, except FireWarden series panels. . FlashScan� (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features • Sleek, low-profile, stylish design. • State-of-the-art thermistor technology for fast response. • Rate-of-rise model (FST-851 R), 15°F (8.3°C) per minute. • Factory preset at 135°F (57°C); high-temperature model at 190°F (88°C). • Addressable by device. • Compatible with FlashScan� and CLIP protocol systems. • Direct dial entry of address 01-159 for FlashScan� loops, 01-99 CLIP mode loops. • Two-wire SLC connection. • Visible LEDs "blink" every time the unit is addressed. • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. • Integral communications and built-in device-rype identifica- tion. • Remote test feature from the panel. • Built-in functional test switch activated by external magnet. • Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). • Low standby current. • Backward-compatible. • Built-in tamper-resistant feature. • Designed for direct-surface or electrical-box mounting. • Sealed against back pressure. • Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. • SEMS screws for wiring of the separate base. • Constructed of off-white Bayblend�, designed to commer- cial standards, and offers an attractive appearance. � � J dn-6936:a1 • H-211 N4T1 FI E R� by Honeywell FST-851 Series in 6710LP base • 94-5V plastic flammability rating. • Remote LED output connection to optional RA400Z remote LED annunciator. • Optional sounder, relay, and isolator bases. • Optional recessed (RMK400) or surface (SMK400E) base mounting kits. Specifications Size: 2.1" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in 6501 base, 6.1" (15.5 cm) diameter installed in 6710LP base. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851 Series, FST-851 R: — 20°C to 38°C (-4°F to 100°F); FST-851 H: —20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% — 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (88°C). Altitude rating: 10,000 feet. ELECTRICAL SPECIFICATIONS: Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 300 uA � 24 VDC (one com- munication every 5 seconds with LED enabled). LED current (max.): 6.5 mA � 24 VDC ("ON"). BASES AVAILABLE: B710LP: 6.1" (15.5 cm) diameter. B501: 4.1" (10.4 cm) diameter. B501 BH-2 or B501 BHT 2: Sounder base assembly. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mrr�). Relay type: Form-C. Rating: 2.0 A� 30 VDC resistive; 0.3 A� 110 VDC inductive; 1.0 A� 30 VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). B224BI Isolator Base: Dimensions: 6.2" (15.748 cm) x 1.2" (15.748 cm). Maximum: 25 devices between isolator bases. See Note 2 under Installation. Applications Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- dn-6936:a1 • 06/8/09 — Page 1 of 2 vides detailed information on detector spacing, placement, zoning, wiring, and special applications. Instaliation The FST Series plug-in intelligent thermal detector uses a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5' (3.81 cm) deep. Suitable boxes include: • 4.0" (10.16 cm) square box. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. • Single-gang box (except relay or isolator base). • With 6501 BH-2 or B501 BHT-2 base, use a 4.0" (10.16 cm) square box. • With 6224R6 or 622461 base, use a 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or a 4.0" (10.16 cm) square box. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4(C/ass "8') wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S747 • ULC Listed: S6978MEA Listed: 383-02-E • FM Approved • CSFM:7270-0028:196 • BSMI: CI313066760025 • CCCF: Certif. # 2004081801000018 • U.S. Coast Guard: 161.002/23/3 (AFP-200); 161.002/27/3 (AFP1010/AM2020); 161.002/42/1 (NFS-640) • Lloyd's Register: 03/60011 Product Line Information "A" suffix indicates ULC Listed model. FST 851: Intelligent thermal detector. Must be mounted to one of the bases listed below. FST851A: Same as FST-851 but with ULC Listing. FST 851 R: Intelligent thermal detector with rate-of-rise feature. FST 851 RA: Same as FST-851 R but with ULC Listing. FST 851 H: Intelligent high-temperature thermal detector. FST-851 HA: Same as FST-851 H but with ULC Listing. BASES: B710LP: Standard U.S. low-profile base 6710LPBP: Standard U.S. low-profile base, pkg. of 10. 6710LP: Standard U.S. low-profile base. 6710LP(A): Standard U.S. low-profile base. B501 BP: Standard European flangeless base, pkg. of 10. 8501: Standard European flangeless base. B501(A): Standard European flangeless base, ULC Listing. BH501BH-2: Sounder base, includes B501base above. BH501 BHT 2: Same as 6501 BH-2, but indudes temporal sounder. BH5016HA: Sounder base, includes B501base above BH501 BHTA: Same as BH501 BHA, but includes temporal sounder. B224BI(A): Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: F110: Retrofit replacement flange for older style high profile bases. Converts bases for use with FlashScan� detectors. RA400Z(A): Remote LED annunciator. 3— 32 VDC. Fits U.S. single-gang electrical box. Supported by B710LPBP(A) and B501(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. RMK400: Recessed mounting kit. For use with B501(A) base only. SMB600: Surface mounting kit for use with B710LPBP(A). BCK-200B: Black detector covers, box of 10. M02-04-00: Test magnet. M02-09-00: Test magnet with telescope stick. XR26: Detector removal tool. Allows installation and/or removal of FlashScan� Series detector heads from base in high ceiling installations. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-ft. sections. Notifie� and FlashScan� are a registered trademark ot Honeywell Intemational Inc. Bayblentl� is a registeretl tratlemark of Bayer Corp. t2009 by Honeywell International Inc. All rights reservetl. UnautMrized use of this docu- ment is strictly prohibitetl. '�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEEIINC ! MANUFAENAINC A�I specifications are subject to change without notice. QUALITI SISTEMS MadeintheU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-711 S. www.notifier.com Page 2 of 2— dn-6936:a1 • 06/B/09 FAPT-851(A) Acclimate� PIusT"" Multi-Sensor Low-Profile Intelligent Detector General The Notifier FAPT-851(A) Acclimate� PIusT"' detector is an intelligent, addressable, multi-sensing, low-profile detector designed for use with Notifier Onyx and CLIP series Fire Alarm Control Panels. The Acclimate Plus detector uses a combination of photoelec- tric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the Accli- mate Plus detector has a microprocessor in the detector head that processes alarm data. As a result, the Acclimate Plus detector adjusts its sensitivity automatically, without operator intervention or control panel programming. Areas where the Acclimate Plus detector is especially useful include office complexes, schools, college campuses, manu- facturing and industrial facilities, and anywhere else the use of a particular area may change. The Acclimate Plus detector automatically adjusts its sensitivity to the environment. FlashScan (U.S. Patent 5,539,389) is a communication proto- col developed to greatly enhance the speed of communication between analog intelligent devices and compatible systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features • Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based, combination photo and thermal technology. • FlashScan� and CLIP system compatible (NFS-320, NFS- 640, NFS2-640, NFS-3030 and NFS2-3030) • Addressable-analog communication. • Sleek, low-profile design. • Two-wire SLC connection. • Direct-Dial entry of address: (1 — 159 on FlashScan sys- tems; 1— 99 on CLIP systems). • Addresses can be viewed and changed without electronic programmers. • Dual bi-color LED design provides 360° viewing angle. • LEDs lock red when in alarm. In FlashScan, LEDs flash green in standby for normal condition. • Built-in tamper-resistant feature. • Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. • SEMS screws for wiring of the separate base. • Several base options, including relay, isolator, and sounder. • Built-in functional test switch activated by external magnet. • Listed to UL 268. • Capable of heat-only alarm mode, enabled by a special command from the panel. Smoke alarms are ignored. • Low-temperature signal at 45°F +/— 10°F (7.22°C +/— 5.54°C). �J DN-6937:C NOTI F'1 E R`�� by H o n eywe I I 6937P�o1.jpq � �� FAPT-851(A) in B710LP base (base ordered separately) Specifications Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft. with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with systems; fixed-sensitivity levels: 1, 2, and 4%/ft. with classic CLIP systems; 0.5, 1, 2, 3, and 4%/ft, with FlashScan systems. Size: 2.0" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in 6501 base, 6.1" (15.5 cm) diameter installed in 6710LP base. Shipping weight: 5.2 oz. (147 g). Operating temperature: 0°C to 38°C (32°F to 100°F). Operating altitude: up to 10,000 feet. UL-Listed velocity range: 0— 4000 ft./min. (1219.2 m/min.), suitable for installation in ducts. Relative humidity: 10% — 93% noncondensing. Thermal sensing rating: fixed-temperature setpoint 135°F (57°C). ELECTRICAL SPECIFICATIONS: Voltage range: 15 — 32 volts DC peak. Standby current (max. avg.): 300 NA. Loop resistance: 50 ohms maximum; varies according to control panel used. Refer to panel installation manuals. LED current (max.): 6.5 mA � 24 VDC ("ON"). Installation The FAPT-851(A) plug-in detector uses a separate base to simpliTy installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove detec- tors without using a ladder. Suitable mounting base boxes include: • 4.0" (10.16 cm) square box. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. • Single-gang box (except relay or isolator base). NOTE: The FAPT-851(A) detector has the unique ability to adjust sensitiviry according to the environment, based on heat and smoke levels. Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a sell-contained heater. DN-6937:C • 10/26/2010 — Page 1 of 2 Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S1115 • ULC Listed: S1115 • MEA Listed: 225-02-E • FM Approved • CSFM:7272-0028:0206 • U.S. Coast Guard: 161.002/42/1 (NFS-640) • Lloyd's Register: 02/60007 (NFS-640) • Maryland State Fire Marshal: Permit # 2122 Ordering Information NOTE: `A"suHix indicates ULC Listed model. FAPT 851: Low-profile intelligent multi-sensor detector. Must be mounted to one of the bases listed below. FAPT 851 A: Same as FAPT-851 but with ULC Listing. INTELLIGENT BASES B501(A): Flangeless mounting base. B200S(A): Intelligent sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces the 6501 BH series bases in retrofit applications. B710LP: Flanged mounting base. (6.1 ", 15.5 cm diameter) B710LPA: Flanged mounting base, ULC Listed. B224R6: Relay base Screw terminals: up to 14 AWG (2.0 mrr�). Relay type: Form-C. Rating: 2.0 A� 30 VDC resistive; 0.3 A� 110 VDC inductive; 1.0 A� 30 VDC inductive. Dimensions: 62" (15.748 cm) x 1.2" (3.048 cm).. B224RBA: Relay base, ULC Listed. 622461: Isolator base. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). Maximum: 25 devices between isolator bases. B224BIA: Isolator base, ULC Listed. ACCESSORIES: F110: Retrofit replacement flange for older high profile bases. Converts bases for use with FlashScan� detectors. RA100Z(A): Remote LED annunciator. 3— 32 VDC. Fits U.S. single-gang electrical box. Supported by B710LP(A) and B501(A) bases only. SM6600: Surface mounting kit for use with 6710LP(A). BCK-2006: Black detector covers, box of 10. M02-04-00: Test magnet. M02-09-00: Test magnet with telescope stick. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan� Series detector heads from base in high ceiling installations. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-ft. sections. Notifier�, ONYX�, FlashScan�, and Acclimate� are registered trademarks and Acclimate PIusTM' is a trademark of Honeywell Intemational Inc. m2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ,•,Y �J, �w.,... .: .,,�,Y.:u� I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requiremen•� .,.,,..�. BlilfiEEllNi i MIWIFACTIRIIV6 All specifications are subject to change without notice. pUALIT� SPSTEYS MadeinmeU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6937:C • 10/26/2010 SpectrAlert� Advance Selectable Output Notification Appliances General System Sensor� SpectrAlert� Advance selectable-output horns, strobes and horn/strobes are rich with features guaran- teed to cut installation times and maximize profits. The Spec- trAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installa- tion of individual devices, and eleven field-selectable candela settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four-inch square, four- inch octagon, or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the producYs tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- ucYs pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: • 12 or 24 volts. • At 24 volts, 15, 15l75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 candela by way of a rear-mounted slide switch and front viewing window. • Horn tones and volume by way of a rotary switch. • The SpectrAlert Advance series includes outdoor notifica- tion appliances. Outdoor strobes and horn/strobes (two- wire and four-wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between —40°F and 151 °F (-40°C and 66°C) in wet or dry applications. Models avaflable: • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4- wire horn/strobe. • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. F@atUl'@S • Plug-in design. • Same mounting plate for wall- and ceiling-mount units. • Shorting spring on mounting plate for continuity check before installation. • Captive mounting screw. • Tamper-resistance capability. • Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75 candela. • Outdoor wall and ceiling products. DN-7087:B1 rJ N OT 1 F 1 E R`J by Honeywell ������� x :. ,: } ,O's,F, � � � ��. � j _ " . °,� Indoor Ceiling Outdoor Ceiling Horn/Strobe Strobe � ,� fi t �` •'Q�� �,,�, C` ` � � � ��� _ — ° �, f�". , ` r � ... .._ ::;�,� : �v Indoor Wall Indoor Ceiling Horn/Strobe Strobe �: �.. ;:;. �F: u; • � Indoor Wall r Outdoor Wall Horn Strobe • Outdoor products rated from —40°F and 151 °F (-40°C and 66°C). • Outdoor products rainproof per UL50 (NEMA 3R) and weatherproof per NEMA 4X, IP56 • Minimal intrusion into the backbox. • Horn rated at 88+ dbA at 16 volts. • Rotary switch for tone selection. • Three horn volume settings. • Electrically compatible with existing SpectrAlert products. Engineering Specifications SpectrAlert Advance horns, strobes, and horn/strobes shall mount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0" (10.16 cm) octagonal backbox, or a double- gang backbox. Two-wire products shall also mount to a single- gang 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- trAlert Advance products, when used with the SynaCircuitT"" Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12- volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F (0°C and 49°C) from a regulated DC, or full-wave-recti- fied, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. DN-7087:81 • 09/27/2010 — Page 1 of 4 STROBE The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-sig- naling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe's entire operating volt- age range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. HORN/STROBE COMBINATION The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and U� 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector sys- tem. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non-Temporal (continuous) pattern. These options are set by a multiple posi- tion switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. OUTDOOR PRODUCTS SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between �0°F and 151 °F (-40°C and 66°C). The products shall be listed for use with a System Sensor outdoor/weather- proof backbox with half-inch and three-fourths-inch conduit entries. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit MDL3R or MDL3W listed to UL 464 and shall be approved for fire protec- tive service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at Temporal 3. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) back- box. The module shall also control two Style Y(class B) cir- cuits or one Style Z(Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more syn- chronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Strobe Current Draw, UL Maximum (mA RMS) 8-17.5V 16-33V Candela DC FWR DC FWR 15 123 128 6 71 15/75 142 148 77 81 Standard 30 NA N/A 94 96 Candela 75 NA NA 158 153 Range 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 135 NA NA 22 7 High 150 NA NA 246 220 Candela Range � �� NA NA 281 251 185 NA NA 286 258 Page 2 of 4— DN-7087:81 • 09/27/2010 Operating Specifications • Standard operating temperature: 32°F to 120°F (0°C to 49°C). • K Series operating temperature: —40°F to 151°F (-40°C to 66°C). • Humidity range: 10% to 93% non-condensing (indoor products). • Strobe flash rate: 1 flash per second. • Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. • Operating voltage range: 8 V to 17.5 V(12 V nominal); or 16 V to 33 V(24 V nominal). NOTE: P, S, PC, and SC prod- ucts will operate at 12 V nominal only for 15 cd and 15/75 cd. • Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mm2). • Ceiling-mount dimensions (including lens): 6.8' diame- ter x 2.5" deep (17.3 cm diameter x 6.4 cm deep). • Wall-mount dimensions (including lens): 5.6" H x 4.7" W x2.5"D(14.2cmHx11.9cmWx6.4cmD). • Horn dimensions: 5.6" H x 4.7" W x 1.3" D(14.2 cm H x 11.9cmWx3.3cmD). Agency Listings and Approvals The listings and approvals below apply to SpectrAlert Advance Selectable Output Notification Devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus. • UL Listed: S4011 (HR_, HW_, P2_, P4_, PC2_, PC4_ models); S5512 (models SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, SRHK, SRK). • ULC Listed: S4011 (HRA, HRKA); S5512 (typically "A" models, with exception of outdoor strobes). See Canadian data sheet for listings and specifications. • FM approved • MEA:452-05-E • CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); 7300-1653:0188 (P2_, P4_, PC2_, PC4_ modules); 7135-1653:0189 (HR, HRK, HW); 7300- 1653:0187 (SCRHK, SCRK, SRHK, SRK). Horn Current Draw, UL Maximum (mA RMS) Horn and Horn/Strobe Rotary Switch Setting Horn and Horn/Strobe Output (dBA) TWvo-Wire Horn/Strobe, STANDARDCandela Range (15 - 115 cd), UL Maximum Current Draw (mA RMS) TWvo-Wire Horn/Strobe, H/GHCandela Range (135 - 185 cd), UL Maximum Current Draw (mA RMS) 1. 1. '. �r=-' 7087tlim12009.iN _-- - - DN-7087:81 • 09/27/2010 — Page 3 of 4 Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire horn/strobe, standard cd, red. PC2R 2-wire horn/strobe, standard cd, red. P2RH 2-wire horn/strobe, high cd, red. PC2RH 2-wire horn/strobe, high cd, red. P2RK 2-wire horn/strobe, standard cd, red, outdoor. PC2RK 2-wire horn/strobe, standard cd, red, outdoor. P2RHK 2-wire horn/strobe, high cd, red, outdoor. PC2RHK 2-wire horn/strobe, high cd, red, outdoor. P2W 2-wire horn/strobe, standard cd, white. PC2W 2-wire horn/strobe, standard cd, white. P2WH 2-wire horn/strobe, high cd, white. PC2WH 2-wire horn/strobe, high cd, white. P4R 4-wire horn/strobe, standard cd, red. PC4R 4-wire horn/strobe, standard cd, red. P4RH 4-wire horn/strobe, high cd, red. PC4RH 4-wire horn/strobe, high cd, red. P4RK 4-wire horn/strobe, standard cd, red, outdoor. PC4RK 4-wire horn/strobe, standard cd, red, outdoor. P4RHK 4-wire horn/strobe, high cd, red, outdoor. PC4RHK 4-wire horn/strobe, high cd, red, outdoor. P4W 4-wire horn/strobe, standard cd, white. PC4W 4-wire horn/strobe, standard cd, white. P4WH 4-wire horn/strobe, high cd, white. PC4WH 4-wire horn/strobe, high cd, white. WALL STROBES CEILING STROBES SR Strobe, standard cd, red. SCR Strobe, standard cd, red. SRH Strobe, high cd, red. SCRH Strobe, high cd, red. SRK Strobe, standard cd, red, outdoor. SCRK Strobe, standard cd, red, outdoor. SRHK Strobe, high cd, red, outdoor. SCRHK Strobe, high cd, red, outdoor. SW Strobe, standard cd, white. SCW Strobe, standard cd, white. SWH Strobe, high cd, white. SCWH Strobe, high cd, white. ACCESSORIES HORNS BBS-2A Backbox skirt, wall, red. HR Horn, red. BBSW-2A Backbox skirt, wall, white. HRK Horn, red, outdoor. BBSC-2A Backbox skirt, ceiling, red. HW Horn, white. BBSCW- gackbox skirt, ceiling, white. ACCESSORIES, continued 2A SA-WBB Weatherproof backbox, wall. MP-2W-206P 2-wire indoor mounting plates, pkg of 20. SA-WBBC Weatherproof backbox, ceiling. conYd at right MPK-2W-20BP 2-wire outdoor mounting plates, pkg of 20. 1. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd" refers to strobes that include 15, 15l75, 30, 75, 95, 110, and 115 candela settings. 2. For strobes and horn/strobes, add suffix "F" for French or "B" for Bilingual. 3. All outdoor models ("K" suffix) include weatherproof backbox. Sync�CircuitTM' is a trademark and NOTIFIER� and SpecVAlert� are registered trademarks of Honeywell Intemational Inc. m2010 by Honeywell Internatlonal Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1S0 �oo� 7his document is not inte�ded to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 6YCIIE91Ni 1 MIWIFACTIAIN6 All specifications are subject to change without notice. pU�LIT1 515TEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-7087:B1 • 09/27/2010 ACPS-610( E) Addressable Charger/Power Supply General The ACPS-610(E) is an auxiliary power supply with a battery charging option and a host of special features. Selectable charging options allow the ACPS-610(E) to provide 6 amps of shared power to four outputs while charging batteries from 12 to 200 AH, or 10 amps of shared power when the unit is configured for use with an external battery charger. Four individually addressable outputs can be independently configured for auxil- iary power or Notification Appliance Circuits (NAC). NAC out- puts support notification appliance synchronization for devices manufactured by System Sensor�, Wheelock, and Gentex. An option to disable battery charging allows the system designer to use the four built-in circuits to distribute 10 amps of power for general purposes, excluding NAC applications. The ACPS-610(E) is compatible with NOTIFIER intelligent fire alarm control panels using CLIP and FlashScan� protocol. Features • Listed to UL Standard 864, 9th Edition. • Provides 6.0 A of NAC power or 10 A of general purpose power. • Four Class B(Style Y) or four Class A(Style Z) outputs, indi- vidually addressable by the FACP. • When built-in outputs are configured for NAC operation, each circuit supports strobe synchronization with the following manufacturers' audio/visual devices: System Sensor (Spec- trAlert� and SpectrAlert Advance Series) or Wheelock or Gentex. • Each circuit can be software-selected for use as: a Notifica- tion Appliance Circuit, general purpose 24 VDC power, four- wire detector power, or door holder. • Steady, March Time (120 PPM), Two Stage, Temporal, or UZC Zone-Coded and Non-Coded devices - software-select- able by circuit. • Universal Zone Coder (UZC-256) option supports for pro- grammable coded outputs. Up to 256 different codes. • Auxiliary Outputs: 24V � 0.5A and 5V � 0.15A • Charges 12 to 200 AH batteries with full supervision. The charger on the ACPS may be disabled via software. When disabled, a separate, external charger is required , for exam- ple a CHG-120. • May be used to provide battery backup for multiple ACPS supplies. • AC loss detection, brownout detection, and AC loss delay reporting. • Power-limited outputs. • Isolated Signaling Line Circuit (SLC) interface. • Selectable ground fault detection. • Canadian two stage operation. dn-60244:b (�J N QT 1 F 1 E R`�� by Honeywell � x , �,, ���; ��:�� �. u<.,<: r a O j � , ; , � "�� ���''I :� ,, d , � _ � .j f iS'/+M �' I - L � " '' y `•�, � � r s,iaj';. �' '� : � � � � "� ��,,'�•e��, , � . !1 � • ,r � ��� • • +� ! ,+9` � +�.�.�d•>�:...s;� ',,r� A �,,e i�f�tl � e � �� �i��� C /�i • L� � ' • �` 1�i ! • � !+ ! ' �. ` ,� r __ :—.._.. .. ,, , .. _ _ _. . Specifications • Primary (AC) power: — ACPS-610: 120 VAC, 50/60 Hz input, 5.0 A maximum — ACPS-610E: 220/240 VAC, 50/60 Hz input, 2.5 A maximum • Output voltage: 24 VDC electrically regulated and power lim- ited (under primary AC mains). Under secondary power, 20.4 to 26.4 VDC. • Output circuits - T63, TB4, TBS, T66 on Main Board: 1.5 A maximum for any NAC output circuit. 2.5 A maximum for any Power output with battery charger disabled. • Secondary power (battery) charging circuit - lead-acid battery charger which will charge 12 to 200 AH batteries. Maximum charger current - 5.0 A. • Secondary power auxiliary outputs - TB2 on CPS-24 Board: — 24V � 0.5A, power limited — 5V � 0.15A, power limited • Wiring: utilizes wire sizes 12 to 18 AWG (3.1 to 0.78 mmz). • SLC specifications: Average SLC current is 1.287 mA. SLC data is transmitted between 24.0 VDC, 5 VDC, and 0 VDC at approximately 3.33 Kbaud. • Battery fuse (F2): 15A, Fast-acting • Weight:4.51b ACPS Programming The ACPS-610(E) is programmable via the simple-to-use PK-PPS programming utility, which requires a Windows� PC with a USB port and cable. A copy of the PK-PPS programming utility is included with each ACPS-610(E). Programming may be performed during an on-line session with the ACPS-610(E), or previously saved programs may be downloaded to individual ACPS-610(E) units. The ACPS-610(E) requires the use of a minimum of 5 SLC address points, and will use up to 14 SLC address points to fulfill requirements for Canadian supervision and two stage operation. dn-60244:b • 4/23/2009 — Page t of 2 ��i ai Chaiqn: 54 charge �55 � 200 AH I Sync Type: EMmnd N2C1 w! SY�Itm S�nca Intemal Siercee6k Ye� Reppinq US AC Fai o��r z na,: OUpW 1�. NAC Sy.icMacM Ouipu 2�. NAC Sy�cMonnd ow� a w,c c�wti diMut l. Powa Reatta6k SLC Addiesang MoriMa Gmaal: b Ou1pU 1: b. t OWpU2 b.2 ONpu13. b.3 Oulput 1. b • ! SqndSknce. 6�5 <Beck Fri�h Cancd Example of Programming for the ACPS-610 Using 6 Addresses �� ui Cha�gm S1 r.haige 155 � 200AHI Coda Type Canadian Dual Staqe: 2 SyncType. E�temd(UZC) w� sw�em sen�w �Mema� Sibnceabk: Yea Repoilnq�. Canadian OUN 1: NAC Coded Ou1pN 2: Powei Rnenable OUpN3 DoorHddc305ecReleeae oawn �: rwc synctwarzed SLC Add�e:sing� Monla Gmnal: Outwt 1 Oulput 2 Outpui 3 OUput 4 SgnalSlencc. Truible Morvtw�vg. AC Ftik Ba�iay Ea�th Faun� Chdgn: Dual Siage� Output 1 o�w z Outp�a 3 OUpiA d b b.l b�2 e.3 6�4 b.5 b.6 b� b.E b.5 h.10 b•11 e.iz b•1? < Back Firvsh _ Caric� Example for ACPS-610 Using Canadian Reporting with Two Stage. Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635 • ULC Listed: S635 • FM Approved • CSFM:7315-0028:248 • MEA #30-08-E Product Line Information ACPS-610: Addressable charger power supply, with selectable built-in synchronization, and four built-in control modules. Includes installation instructions and PK-PPS programming util- ity CD. Requires Windows PC with USB port and USB cable. Several mounting options available (see below). ACPS-610E: Same as ACPS-610, but configured for 220/240 VAC operation. CAB-PS1: The CAB-PS1 can house one ACPS-610(E) and two 12 AH batteries. Dimensions: 15.218" (38.654 cm) high x 14.5" (36.83 cm) wide x 3.562" (9.048 cm) deep with door. DR-PSi: When installing an ACPS-610(E) into an older version of the CAB-PS1 used for an ACPS-2406(E), the new wider door must be ordered for use with the older version cabinet. BB-25: The BB-25 can house one ACPS-610(E) and two 12 volt, 26 AH batteries. CAB-4 Series: The ACPS-610(E) can mount in any of the CAB-4 Series cabinets. This can be in the bottom of the cabinet or a tier via a CHS-PS and CHS-BH. See CAB-4 Series data sheet (DN-6857). EQ Cabinet Series: The ACPS-610(E) can mount in any of the EQ Cabinet Series cabinets. See EQ Cabinet Series data sheet (DN-60229). CHS-PS/CHS-6: Power supply mounting plate. Optional kit used to mount the ACPS-610(E) in a location other than the bot- tom of the CAB-4 cabinet or in an EQ Series cabinet (e.g., 2nd, 3rd, or 4th tier). CHS-BH: Battery mounting chassis used to mount batteries in a location other than the bottom of the CAB-4 cabinet (e.g., 2nd, 3rd, or 4th tier). Batteries: ACPS-610(E) battery charging circuit range is 12 - 200 AH. See BAT Series data sheet (DN-6933). Notifier�, FlashScan�, System Sensor�, and SpectrAlert� are registered trademarks of Honeywell Intemational Inc. m2009 by Honeywell International Inc. All rights reserved. Unauthorized use of ttiis document is strictly prohibited. I S 0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENi1�EE811� 6 MANIFAC1111Ni All specifications are subject to change without notice. QU�LIT� S�STEMS MadeinmeU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-60244:b • 4/23/2009 SpectrAlert� Advance Indoor Selectable Output Speaker Strobes and Dual Voltage Evacuation Speakers General The SpectrAlert Advance Series of speakers and speaker strobes is designed to reduce ground faults. The plug-in design allows the installer to pre-wire mounting plates and dress the wires before plugging in the speakers. The plastic cover pre- vents nicked wires by covering exposed speaker components. This design also allows faster installations with instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 11 field selectable can- dela settings for wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while the SPV speaker offers high volume sound output for use in high ambient noise applications. SpectrAlert Advance makes installation easy • Attach a universal mounting plate to a 4" x 4" x 2-1l8" back box. Flush mount applications are achievable without the need for an extension ring. • Connect the notification appliance circuit or speaker wiring to the PEMS terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Rotate the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mount- ing screw. Features • Plug-in design • Protective cover isolates speaker components, redu ground faults • Electrical compatibility with existing SpectrAlert products • Field selectable candela settings on wall and ceiling units: - Standard: 15, 15l75, 30, 75, 95, 110, 115 - High: 135, 150, 177, 185 • Shorting spring on mounting plate tests continuity be installation ces fore • Rotary switch simplifies field selection of speaker voltage and power settings • Universal mounting plate for wall- and ceiling-mount units • Compatible with System Sensor synchronization protocol • SP speakers offer high fidelity sound output • SPV speakers offer high volume sound output • Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela • No extension ring required • Ceiling and wall mount application • Optional tamper resistant Torx head screw included Specifications PHYS/CAL SPEC/FICATIONS Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity Range: 10 to 93% non-condensing Dimensions, Wall-Mount: SPS Speaker Strobe: 6.0"L x 5.0"W x 4.7"D (includes lens and speaker) �J dn-60327:a2 NOTI FI E R� by Honeywell ..,�... ..... ,,. ...... ,. ��,r � � • . . ._..-.,........:�,,, ... • .....,--�.�--� � ..--..... ,°�•-----. � �� — �,^,.�,.'�.�., ,,. � �, -- -- I _.. y„ �� ____ -.---=_ -��-..,..�---... i � ��� . ; � ,,,,�-...: _._ ��,,�_ .,�-..-,-,._ �, ����..... _ ,_ �.� ,.. . � . �"� � a .....„. ��VW�,,.�,. I�m', R'f i� •'£ �.a � �- SPSV Speaker Strobe: 6.0"L x 5.0"W x 4.9"D (includes lens and speaker) SP Speaker: 6.0"L x 5.0"W x 2.8"D SPSV Speaker: 6.0"L x 5.0"W x 2.9"D Dfinensions, Ceiling-Mount: SPS Speaker Strobe: 6.8"Dia x 4.7"D (includes lens and speaker) SPSV Speaker Strobe: 6.8"Dia x 4.8"D (includes lens and speaker) SP Speaker: 6.8"Dia x 2.8"D SPSV Speaker: 6.8"Dia x 2.9"D ELECTRICAL/OPERATING SPECIFICATIONS Nominal Voltage (speakers): 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers): 50VDC Strobe Flash Rate: 1 flash per second Nominal Voltage (strobes): Regulated 12VDC/FWR or regu- lated 24DC/FWR Operating Voltage Range (includes fire alarm panels with built-in sync): 8 to 17.5V (12V nominal) or i6 to 33V (24V nominal) Operating Voltage with MDL Sync Module: 9 to 17.5V (12V nominal) or 17 to 33V (24V nominal) Frequency Range: 400 to 4000 Hz Power: '/a, Yz, 1, 2 watts Agency Listings and Approvais In some cases, certain modules may not be listed by certain approval agencies, or listing may be in progress. Consult fac- tory for latest listing status. • UUULC Listed: S4048 • MEA:10-08-E • CSFM:7320-1653201 • FM Approved dn-60327:a2 • 5/28/10 — Page 1 of 2 Architectural/Engineering Specifications GENERAL S,pectrAlert Advance speaker and speaker strobes shali mount to a 4 x 4" x 2-1/8" backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes when used with the Sync Circuit. Module accessory, shall be wered {rom a non-coded notification appli- ance circuit output and sha�operate on a nominal 12 or 24volts. When used with the Sync.Circuit Module, 12 volt rated notification appliance cir- cuit outputs shall operate between nine and 17.5 volts; 24 volf rated notifi- cation appliance arcwt outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power suppIy. Speaker strobes shall have field-selectable candela settings including 15, 15l75, 30, 75, 95, 110, 115, 135, 150, 177, 185. SPEAKER The speaker shall be a System Sensor SpectrAlert Advance model dual-voltage transformer speaker capable of operating at 25.0 or . nominal Vrms. It should be listed to UUULC 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4000Hz and shall have an operating temperature between 32°F and 120°F. Speaker shall have power taps and voltage that are selected by rotary switches. SPEAKER STROBE COMBINATION The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UWLC 1971 and be approved for fire pro ec ive signaling systems. Speaker shall be capable ot operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have alre- quency range of 400 to 4000Hz. Speaker shall have power taps which are selected by rotary, switch, The strobe shall compiy with the NFPA 72 requirements for visibie signaling appliances, flashinq at 1 Hz over the strobe's entire operating voRage range. The strobe lighi shall consist of a xenon flash tube and associated lens/reflector system. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync Circuit model MDL listed to UWLC 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 4-11/16" x 4-11/16" x 2-1/8" backbox. The module shall also controi two Style Y(class B) circuits or one Style Z(class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Ordering Information NOTE: (W) indicates white coloring; (R), red. NOTE: `A"suHix indicates ULC-Listed model. WALL MOUNT SP(W)(R)(A): Speaker only. SP(W)(R)V(A): Speaker only, high d6; white. SPS(W)(R)(A)•: Speaker strobe, selectable candela (15, 15/75, 30, 75, 95, 110, 115). SPS(W)(R)H(A)•: Speaker strobe, selectable candela, high cd (135, 150, 177, 185). SPS(W)(R)V(A)`: Speaker strobe, selectable candela, high dB. CEILING MOUNT SPC(W)(R)(A): Speaker only. SPC(W)(R)V(A): Speaker only, high dB. SPSC(W*)(R)(A): Speaker strobe, selectable candela (15, 15/ 75, 30, 50, 75, 95, 110, 115) SPSC(W*)(R)H(A): Speaker strobe, selectable candela, high cd (135, 150, 177, 185) SPSC(W')(R)V(A): Speaker strobe, selectable candela, high dB (15, 15/75, 30, 50, 75, 95, 110, 115). SPSC(W*)(R)VH(A): Speaker strobe, selectable candela, high dB, high cd (135, 150, 177, 185). ACCESSORIES RFP(A): Retrofit plate (5 pack), red. RFPW(A): Retrofit plate (5 pack), white. SPBBSC(A): Ceiling mount backbox skirt, red. SPBBSCW(A): Ceiling mount backbox skirt, white. SPBBS(A): Wall mount backbox skirt, red. SPBBSW(A): Wall mount backbox skirt, white. TR(A): Wall mount trim ring, red. TRW(A): Wall mount trim ring, white. TRC(A): Ceiling mount trim ring, red. TRCW(A): Ceiling mount trim ring, white. `NOTE: Add -P to model number for plain housing (no 'FIRE' marking on the cover), e.g. SPSW-P SpectrAlert� is a registered trademark of Honeywell International Inc. m2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements EN�II�EERII� � MANUFACiIAINi All specifications are subject to change without notice. QUALITI SYSTEMB MadeinmeU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- dn-60327:a2 • 5/28/10 FSL-751 DNR(A) High Sensitivity Duct Smoke Detector General The FSL-751 DNR(A) high sensitivity duct smoke detector pro- vides dependable performance for management of fans, blow- ers, and air conditioning systems by using an intelligent laser smoke sensor residing in an efficient housing design that sam- ples air currents passing through a duct. The twist-in, twist-out FSL-751 DNR high sensitivity laser smoke detector head allows easy removal for quick cleaning, maintenance, and replacement without removing the duct housing. The laser detector achieves sensitivities as low 0.02 percent-per-foot by using a laser diode instead of a standard LED light source in the sensing chamber. Many sensitive areas cannot tolerate even small amounts of smoke. This FSL-751DNR detector is designed to protect valuable assets and operations where sys- tems must remain online at all times. Some ideal applications for the FSL-751 DNR high sensitivity duct smoke detector include: • Telecommunications switching facilities • Cellular telephone infrastructure • Integrated circuit fabrication facilities • Computer rooms • Clean rooms DN-60333: B (�J N OT 1 F 1 E R`�� by H o n eywe I I Max. Standby Current: 230 NA � 24 VDC (without com- munication); 330 NA � 24 VDC (one communication every 5 sec. with LED enabled) Max. Alarm Current: 6. mA (LED on) Features • Temperature Range of 32°F to 100°F (0°C to 38°C) • Air Velocity Rating from 300 to 4,000 fpm • 24 VDC operation NFPA 76, Section 8.5.3.1.2.3 Uery Early Warning Fire Protec- • Versatile mounting options: Easy and quick mounting to tion, calis for sensors to be mounted at the return air location round or rectangular ducts from 1 ft to 12 ft(0.3 m to 3.7 m) for a space in the following instances. wide A. "Where stand-alone packed HVAC units are installed, • Patented sampling tube installs from front or back of the sensors or ports shall be installed where return air is detector with no tools required. brought back to the unit:' • New Cover-tamper signal B. "Sensors or ports shall be installed such that each cov- • Increased wiring space with a newly added 3/4-inch conduit ers no greater than 0.4 m2 (4 ft2) of the return air opening:' . Clear cover for convenient visual inspection The FSL-751DNR high sensitivity duct smoke detector is designed to satisfy NFPA 76 for Very Early Warning Fire Pro- tection. NOTE: Unless othenvise specified, the term FSL-751 DNR refers to both the FSL-751 DNR and ULC-listed FSL-751 DNRA. Specifications PHYS/CAL SPEC/FICATIONS Size: • Rectangular: 14.38 in (37 cm) Length; 5in (12.7 cm) Width; 2.5 in (6.6 cm) Depth • Square: 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width ; 2.5 in (6.35 cm) Depth Shipping Weight: 2.0 Ibs (0.9 kg) Operating Temperature Range: 32°F to 100°F (0°C to 38°C) Storage Temperature Range: -22°F to 100°F (-30°C to 38°C) Operating Humidity Range: 10% to 93% relative humidity Air Duct Velocity: 300 to 4000 ft/min. (0.5 to 20.32 m/sec.) ELECTR/CAL SPECIFICATIONS Voltage: 24 VDC Power Supply Voltage: 15 to 32 VDC Current Requirements (using no accessories) • Remote testing capability (requires auxiliary 24VDC power) • 3 year warranty Architectural/Engineering Specifications The high sensitivity air duct smoke detector shall be a Notifier model FSL-751 DNR high sensitivity duct smoke detector. The detector shall be UL Listed per UL 268A, Standard for Smoke Detectors for Duct Applications, specifically for use in air han- dling systems. The detector shall operate at air velocities from 300 feet per minute to 4000 feet per minute. The detector shall have an operating temperature of 32°F to 100°F (0°C to 38°C). The detector housing shall be equipped with an integral mounting base capable of accommodating laser smoke detec- tor heads; it shall fit both square and rectangular footprints; it shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY or RTS151 Remote Test Sta- tion. The duct detector housing shall incorporate an airtight smoke chamber in compliance with UL Standard 268A. The housing shall be capable of mounting to rectangular or round ducts up to 12 feet wide without adapter brackets. Sampling tubes shall be installed after the housing is mounted to the duct by passing through the duct housing. Terminal connec- tions shall be of the strip and clamp method suitable for 12 to 18 AWG wiring. DN-60333:6 • 09/01 /2010 — Page 1 of 2 Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S1115 • ULC Listed: S911 • CSFM:3240-0028:0205 Ordering Information NOTE: (A) suffix denotes Canadian product. FSL-751 DNR: High sensitivity duct smoke detector. (Replaces FSL-751 D) FSL-751DNRA: ULC-listed high sensitivity duct smoke detec- tor. (Replaces FSL-751 D) FSL-751(A): Replacement intelligent laser sensor head. (For ULC-listed model, order "A" version.) ACCESSORIES DST 1: Metal sampling tube duct widths up to 1 ft(0.3 m). DST 1.5: Metal sampling tube duct widths 1 ft to 2 ft(0.3 m to 0.6 m) DST 3: Metal sampling tube duct widths 2 ft to 4 ft(0.6 m to 2.4 m) DST 5: Metal sampling tube duct widths 4 ft to 8 ft(1.2 m to 2.4 m) DST 10: Metal sampling tube duct widths 8 ft to 12 ft (2.4 m to 3.7 m) DCOIL: Remote Test Coil (included) ETX: Metal exhaust tube duct width 1 ft(0.3 m) P48-21-00: End cap for sampling tubes, metal. RTS151(A): Remote test station. RTS151 KEY(A): Remote test station with key. RA100Z(A): Remote annunciator alarm LED. M02-04-00: Test magnet. NOTIFIER� is a registered trademark of Honeywell Internadonal Inc. m2010 by Honeywell International Inc. All rights reserved. Unauthorized use of ttiis document is strictly prohibited. I�O 9001 7his document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. auir�ain� i nun�FKn�nc All specifications are subject to change without notice. QUALITY S�STEMS MadeintheU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www. notifier.com Page 2 of 2— DN-60333: B• 09/01 /2010