Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B04-0252 Mechanicl Electrical and Plumbing indexes full size
r- VAV -4A9 I LO _.__ TRANE VCWF 10 CODE AREA LOCATION MANUFACTURER/ MODEL NO. CFM SUPPLY 'W.C. FAN ESP 'W.C, HP MIN. OSA AIR COOLING AT (F) HANDLING CAPACITY TOTAL MBH (CHILLED SENS MBH GPM WATER) WPD (FT) UNIT APD 'W.C, SCHEDULE HEATING EAT (F) CAP CAP MBH CHEATING WATER) WPD GPM (FT) (MODULAR APD 'W.C. PRE FILTER APD ('W,C) TYPE INITIAL OR CUSTOM) TYPE OM) FINAL APD ('W.C,) VOLT PH FLA MAX FUSE ELECTRICAL DISC FEEDER SIZE PANEL PANEL OCPD WEIGHT (LBS) AHU CONFIG REMARKS DB VB FINAL INITIAL FINAL (AHU) SERVED (ALT.) (ALT,) (CFM) 7'3 S9 24.42 24.42 6.31 0.35 0.7 49.2 37.75 3.04 0.35 0.11 'ILj!� • • r te/ i 460 3 L6 3A FRS -R 30A /3P 3 #12, 1 #12G, 3/4'C VERT K AHU -2131 BEVERAGE SERVICE LEVEL 2 TRANE I #CVCO36 if25 S 0.4 0,75 220 76.85 6,16 0.64 0,11 460 3 3 6A FRS -R 30A/3P 3 #12 , 1 #1213, 3/4`C VERT K AHU -2B2 COAT CHECK LEVEL 2 TRANE BCVC072 2010 0.8 0.2 1.5 430 78 59 40,47 40.47 25.2 5.6 0.71 47.3 460 3 3 6A FRS -R 30A /3P 3 #12, 1 #12G, 3/4 VERT K AHU -2B3 STAFF DINNING LEVEL 2 TRANE BCVC072 1820 09 0.4 1.5 1300 81 59 41.54 41,54 24,8 5,45 0.56 7.1 115,9 13.23 2,77 0,13 460 3 3.4 6A fRS -R 30A /3P -C 3 #12, 1 #1213, 3/4'C VERT K AHU -2B4 ENGINEERING LEVEL 2 TRANE BCVC072 2475 1,21 0,4 2 335 78 51 49,76 49,76 31,3 8.32 0.88 54 80,85 6,42 0.7 0.14 460 3 7.6 10A FRS -R 30A /3P 3 #12, 1 #1213, 3/4'C VERT K AHU -3A1 NORTH OFFICES / RETAIL LEVEL 3 TRANE MCC 10 4935 2 1,18 5 810 79 59 85.8 80.5 15,5 6,79 0,31 52,2_94 7.93 0.24 0,05 460 3 7,6 10A FRS -R 30A /3P 3 #12, 1 #12G, 3/4'C • i HORIZ K AHU -3A2 SOUTH OFFICES LEVEL 3 TRANE MCC 08 3675 2.5 5 565 79 59 68.6 56,4 12,4 3,76 0.38 57,5 58,4 4,9 0.09 0,05 460 3 if 30A /3P 3 #12, 1 #12G, 3/4R C 'C H ORIZ K AHU -3B1 SPA /HR LEVEL 3 TRANE MCC 14 6285 119 1 7.5 1660 78 59 160 150.4 28,8 6,97 0.56 43,6 202.8 17.02 0,88 0.13 460 3 1,6 3 3 A FRS-S -R A 30A/3P 3 #12, f #1213, 3/4 ' V V ERT J AHU -3132 LAUNDRY LEVEL 3 TRANE BCVCO36 1220 1 0.35 0.75 340 78 59 25,94 25.94 10,1 10,41 0.71 42.4 43,45 3.5 0.46 0.11 460 3 14 20A FRS -R 30A /3P 3 #12, 1 #12G, 3/4'C HORIZ K AHU -3B3 BALLROOM LEVEL 3 TRANE MCC 12 6400 1,85 0,75 10 4500 8i 62 175 151,5 31.5 8,99 0.65 8,1 265 19,97 1,45 0.06 460 3 14 20A FRS -R 30A/3P 3 #12, 1 #12G, 3/4'C HORIZ K AHU -3B4 BREAKOUT /PRE FUNC LEVEL 3 TRANE MCC 14 7015 1,95 0.75 10 3950 80 60 190 177.6 34.2 5.7 0.78 13.3 248,5 19.87 0.6 0.08 460 3 7.6 10A FRS -R 30A /3P 3 #12, 1 #12G, 3/4'C HORIZ K AHU -4Al LOBBY / RETAIL LEVEL 4 TRANE MCC 10 4860 2 0,71 5 730 80 60 110 109.98 19.8 9.45 0,79 53,7 90 7.61 0,23 0.05 460 3 FRS -R 30A/3P 3 #12, 1 #12G, 3/4`C RIZ K AMU -4A2 LOBBY LEVEL 4 TRANE MCC 06 2700 2 1,13 3 405 80 60 54,87 54.87 9.89 10.93 0.49 53,7 90 7,55 0,93 0,08 460 3 3 6 A 6A FRS -R 30A/3P 3 #12, 1 #1213, 3t4`C V VERT K LOADING CORRIDOR LEVEL 4 TRANE BCVCO54 2105 1.5 0.5 1,5 355 78 59 43,'97 43.95 19.6 16,44 0,71 51,3 90,18 7.36 0,32 0,11 3 11 15A FRS - R 30A /3P 3 #12, 1 #12G, 3/4'C HORIZ K AHU -4131 0 f60 28 a Al 0 Al 3i 286 5 21.4 2.58 0.07 460 AHU -5B2 BAR E�NE'RAL NOTES PROVIDE HIGH EFFICIENCY MOTORS (RELIANCE E+ OR EQUIVALENT) PROVIDE CFIELD3,1FACTORY3 MOUNTED [STARTER3,[COMBINATION STARTER /DISCONNECT WIRED TO MOTORS LAND FACTORY COMMISSIONED] 'ITH AUXILIARY CONTACTS AND HOA SWITCH ON ALL THREE PHASE MOTORS INSTALL UNITS WITH ADEQUATE CLEARANCE FOR COIL PULL , FILTER REPLACEMENT AND TO FULLY OPEN ACCESS DOORS. PROVIDE A MINIMUM OF 3 FEET CLEARANCE IN FRONT OF DISCONNECTS SWITCHES AND CONTROL PANELS. COMPLY FULLY WITH NEC, UNIT STATIC PRESSURE CAPABILITY SHALL INCLUDE SCHEDULED EXTERNAL STATIC PRESSURE PLUS ALL SCHEDULED INTERNAL PRESSURE DROPS, INCLUDE VALVES FOR WETTED COILS AND DIRTY FILTERS, SCHEDULED FAN VALUES (CFM, SP AND HP) ARE ACTUAL AT ALTITUDE, MOTOR HP HAS BEEN ADJUSTED FROM SEA LEVEL CONDITIONS FOR OPERATION AT JOBSITE ELEVATION, JOBSITE ELEVATION = 820OFT. CHILLED WATERw EWT = 46 F, LWT = 58 F, 30% PROPYLENE GLYCOL, 0.0005 FOULING FACTOR, HEATING WATERS EWT= 178 F, LWT =153 F, 30'/. PROPYLENE GLYCOL, 0,0005 FOULING FACTOR, PROVIDE DUCT SMOKE DETECTORS IN THE SUPPLY AND RETURN AIR OF ALL UNITS 2000 CFM OR GREATER, REi SPECIFICATIONS. PROVIDE FREEZE STAT DOWNSTREAM OF HEATING COIL. EMARK NOTES PROVIDE FACTORY INSTALLED LAND WIRED TO AN EXTERIOR MOUNTED SWITCH, 120V POWER CONNECTION BY DIVISION 163 MARINE LIGHTS IN [FAN], [ACCESS] SECTIONS, PROVIDE WINDOWS IN ACCESS DOORS OF [FAN], FILTER3,CFILTER /MIXING3, (ACCESS] SECTIONS. PROVIDE INLET VANES ON [SUPPLY] LAND EXHAUST /RELIEF FANS3, SUSPEND UNIT FROM STRUCTURE WITH VIBRATION ISOLATORS, MOUNT UNIT ON 4' CONCRETE HOUSEKEEPING PAD, PROVIDE FACTORY MOUNTED CONTROLS AS FOLLOWS - INDEPENDENT DDC CONTROLLER CONE PER AIR HANDLER) FACTORY WIRED AND COMMISSIONED AND POWERED BY THE CONTROL POWER TRANSFORMER LOCATED IN THE STARTER / DISCONNECT. - MIXING BOX ELECTRONIC SPRING RETURN ACTUATORS. - AVERAGING TYPE ANALOG AIR SENSOR MOUNTED IN MIXING BOX OR ECONOMIZER CONTROL INPUT. - DISCHARGE AIR ANALOG SENSOR MOUNTED IN F AN DISCHARGE, - DIFFERENTIAL PRESSURE SWITCH (BINARY) MOUNTED ACROSS ALL FILTER SECTIONS - DIFFERENTIAL PRESSURE SWITCH (BINARY) MOUNTED ACROSS ALL FANS. -LOW LIMIT FREEZE STATS, SINGLE POLE, DOUBLE THROW MOUNTED ON THE LEAVING SIDE OF HEATING COILS, - ELECTRONIC MODULATING 12 WAY] 13 WAY] SPRING RETURN, NORMALLY CLOSED CHILLED WATER VALVES. - ELECTRONIC MODULATING [2 WAY] [3 WAY] SPRING RETURN, NORMALLY OPEN HEATING WATER VALVES, i. FILTERS (EDIT FOR JOB)' PRE FILTER (8) 24' X 24 24' X 20'/(2) 20' X 20' - ASHRAE 30 "/. EFF„ - 2' PLEATED THR[I1J -AWAY, FINAL FiLTERi FARR 'GLIDE -PAK' OR EQUIV;;',- ASHRAE 90% EFF., - 12' RIGID CARTRIDGE. I, PROVIDE (INTERNAL)(EXTERNAL) VIBRATION ISOLATION, PROVIDE SINGLE POINT ELECTRICAL CONNECTION, J. UNIT 13A COMES FROM MAKE -UP AIR UNIT SERVING SAME AREA, DEMAND CONTROLLED VENTILATION (CO2 SENSOR), - 12NEIGURATIUN )ESIGNER- NUMBER AND VERBALLY DESCRIBE THE CONFIGURATION OF EACH UNIT, EXAMPLES L CONSTANT VOLUME UNIT WITH FILTER MIXING BOX, HEATING COIL, MEDIUM ACCESS DOOR, CHILLED WATER COIL, AND FAN SECTION.<,.(ETCJ ECTION, ALL SECTIONS TO HAVE MIN, 12' WIDE ACCESS DOORS, IL VARIABLE AIR'..VOLUME UNIT WITH VFD DRIVE AND MIXING BOX, PREFILTER, FINAL FILTER, 18' BLANK SECTION, GAS FURNACE, DX COIL, FAN WITH VERTICAL DISCHARGE AND CONDENSER S FAN SECTION TO ,i AVE .PL"nrr,oATC"n I IMCD re'rr N - ■ww�,wrwwr�wrirw VAV -582 S SPECIALTY RESTAURANT T TRANE VCWF 14 2 2000 6 600 3 320 r m im a 'ILj!� • • r te/ i �� ��� •t• ��� om Rm R.i:�� • i ice; #� �� VAV -582 S SPECIALTY RESTAURANT T TRANE VCWF 14 2 2000 6 600 3 320 r GENERAL NOTES 1, CONTROLS SHALL BE BY MANUFACTURER OR BY CONTROL MANUFACTURER AND INSTALLED' AT THE FACTORY (SEE SPECIFICATIONS). 2. FOUNT WITH 5 STRAIGHT DUCT DIAMETERS UPSTREAM OF THE BOX. 3. MAXIMUM INLET S.P.= 0.75 IN. 4. MAXIMUM NC LEVELS ARE RADIATED SOUND DATA AND BASED ON THE MAXIMUM BOX CFM LISTED AND AT A PRESSURE DROP ACROSS THE BOX OF 2.0". 5. EWT= 178F, RPROPYL.ENE GLYCOL= 30 %. REMARK NOTES A. PROVIDE SOUND ATTENUATOR DOWNSTREAM, B. PROVIDE (2WAY)(3WAY) CONTROL VALVES. MAKE UP AIR UNIT SCHEDULE (GAS) MANUFACTURER/ AREA LOCATION WEIGHT ESP CAPACITY (MBH) ELECTRICAL CODE MODEL NO. SERVED fts) CFM (ALT,)(IN,) INPUT (SL) OUTPUT (ALT.) HP VOLT PH FLA FUSE DISCON. FEEDER REMARKS MAU -1 STERLING NO, MS -80 -G BANQ KITCH 215 Mech 508 1439 5550 1,5 500 298.5 7.5 480 3 11 15A FRS -R 30A /3P 3 #12, 1 #12G, 3/4 A - F MAU -2 STERLING NO. MS -80-G BANG KITCH 215 Mech 508 1439 4500 1.5 500 298.5 7.5 480 3 11 15A FRS -R 30A /3P 3 #12, 1#12G, 3/4'C A - I3 MAU -3 STERLING NO, MS -80 -G SHOW KITCH 423 Mech 463 1704 6800 118 700 417.9 7,5 480 3 11 15A FRS -R 3OA /3P 3 #12, 1 #/213, 3 /4'C A - F MAU -4 STERLING NO, MS -80 -G MAIN KITCH 432 Load 410 1439 5500 1,8 500 298.5 7.5 480 3 11 15A FRS -R 30A /3P 3 #12, 1#12G, 3/4'C A - F 7600 t o Inn 417.9 7.5 480 3 11 15A FRS -R 30A/3P_ 3 #12, 1 #1213, 3/4'C A - D MAU -5 STERLING NO, MS -80 -G_ _ __- LAUNDRY Laad 410 1724 SEPARATED COMBUSTION INDOOR UNIT Wt 409 SS HEX PROVIDE HIGH EFFICIENCY MOTOR, PROVIDE DUCT SMOKE DETECTOR IN ALL UNITS OVER 2000 CFM. REi SPECIFICATIONS PROVIDE FILTER SECTION WITH 2' WASHABLE FILTERS SCHEDULED FAN VALUES (CFM, SP AND HP) ARE ACTUAL AT ALTITUDE, MOTOR HP HAS BEEN ADJUSTED FROM SEA LEVEL CONDITIONS FOR OPERATION AT JOBSITE ELEVATION, JOBSITE ELEVATION = 8200 FT, EMARK NOTES PROVIDE HORIZONTAL CONCENTRIC VENT KIT, PROVIDE ELECTRONIC MODULATING GAS CONTROL W/ DUCT SENSING, FREEZESTAT WITH TIME DELAY PROVIDE REMOTE CONTROL PANEL WITH LOCAL OVERRIDE, W/ 24V DPDT INTERLOCK RELAY,. 24V/115V COIL SPDT AUX.RELAY PROVIDE FACTORY MOUNTED CONTROLS, FREEZESTAT W /TIME DELAY. PROVIDE 2 -SPEED MOTOR OPTION] LOW SPEED INTERLOCKED WITH HOOD -OFF OPERATION PER SPECIFIED SEQUENCE PROVIDE OUTSIDE & RETURN AIR INTERLOCKED DAMPERS WITH MODULATING DAMPER, MIN, POSITION PDT, LEVE AHU -5B1 RESTAURANT L 5 TRANE MCC 14 5600 1,85 0,75 7.5 3545 83 59 16 LEVEL 5 TRANE MCC 14 6885 2,15 1 10 3695 79 60 184 168.8 33,2 5,37 0.86 21.5 255 21,4 0.69 0,06 460 3 14 20A FRS -R 30A - 3 #12, 1 #1213, 3/4'C HORIZ VAV BOX SCHEDULE DESIGN CFM MANUFACTURER/ CODE AREA SERVED MODEL NO. COOLING HEATIN VAV -381 SERVICE CORRIDOR TRANE VCWF 12 1575 475 VAV -382 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV -383 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV -3B4 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV -385 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV -386 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV- -387 PRE- CONVENE TRANE VCWF 10 1000 290 VAV -3B8 PRE- FUNCTION TRANE VCWF 16 2815 845 VAV -3139 BALLROOM TRANE VCWF 12 1280 385 VAV -•31310 BALLROOM TRANE VCWF 08 640 195 VAV -3811 BALLROOM TRANE VCWF 12 1280 365 VAV -3812 BALLROOM TRANE VCWF 12 1280 385 VAV -3813 BALLROOM TRANE VCWF 08 640 195 VAV -3814 BALLROOM TRANE VCWF 12 1280 385 VAV -3815 SPA LOCKERS TRANE VCWF 14 1525 490 VAV -3B16 LOCKERS 319/320 TRANE VCWF 10 825 250 VAV -3817 HUMAN RES TRANE VCWF 08 470 140 VAV -31318 UNIFORM ISSUE TRANE VCWF 08 530 160 VAV - 3BIS SPA TRANE VCWF 10 1015 305 VAV -3820 H.R. MANAGER TRANE VCWF 05 245 75 VAV -581 BAR TRANE VCWF 12 1450 435 v a i r4 MW o If all"t �� 0 40 MAU -5 STERLING NO, MS -80 -G_ _ __- LAUNDRY Laad 410 1724 SEPARATED COMBUSTION INDOOR UNIT Wt 409 SS HEX PROVIDE HIGH EFFICIENCY MOTOR, PROVIDE DUCT SMOKE DETECTOR IN ALL UNITS OVER 2000 CFM. REi SPECIFICATIONS PROVIDE FILTER SECTION WITH 2' WASHABLE FILTERS SCHEDULED FAN VALUES (CFM, SP AND HP) ARE ACTUAL AT ALTITUDE, MOTOR HP HAS BEEN ADJUSTED FROM SEA LEVEL CONDITIONS FOR OPERATION AT JOBSITE ELEVATION, JOBSITE ELEVATION = 8200 FT, EMARK NOTES PROVIDE HORIZONTAL CONCENTRIC VENT KIT, PROVIDE ELECTRONIC MODULATING GAS CONTROL W/ DUCT SENSING, FREEZESTAT WITH TIME DELAY PROVIDE REMOTE CONTROL PANEL WITH LOCAL OVERRIDE, W/ 24V DPDT INTERLOCK RELAY,. 24V/115V COIL SPDT AUX.RELAY PROVIDE FACTORY MOUNTED CONTROLS, FREEZESTAT W /TIME DELAY. PROVIDE 2 -SPEED MOTOR OPTION] LOW SPEED INTERLOCKED WITH HOOD -OFF OPERATION PER SPECIFIED SEQUENCE PROVIDE OUTSIDE & RETURN AIR INTERLOCKED DAMPERS WITH MODULATING DAMPER, MIN, POSITION PDT, LEVE AHU -5B1 RESTAURANT L 5 TRANE MCC 14 5600 1,85 0,75 7.5 3545 83 59 16 LEVEL 5 TRANE MCC 14 6885 2,15 1 10 3695 79 60 184 168.8 33,2 5,37 0.86 21.5 255 21,4 0.69 0,06 460 3 14 20A FRS -R 30A - 3 #12, 1 #1213, 3/4'C HORIZ VAV BOX SCHEDULE DESIGN CFM MANUFACTURER/ CODE AREA SERVED MODEL NO. COOLING HEATIN VAV -381 SERVICE CORRIDOR TRANE VCWF 12 1575 475 VAV -382 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV -383 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV -3B4 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV -385 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV -386 BREAKOUT ROOM TRANE VCWF 08 640 195 VAV- -387 PRE- CONVENE TRANE VCWF 10 1000 290 VAV -3B8 PRE- FUNCTION TRANE VCWF 16 2815 845 VAV -3139 BALLROOM TRANE VCWF 12 1280 385 VAV -•31310 BALLROOM TRANE VCWF 08 640 195 VAV -3811 BALLROOM TRANE VCWF 12 1280 365 VAV -3812 BALLROOM TRANE VCWF 12 1280 385 VAV -3813 BALLROOM TRANE VCWF 08 640 195 VAV -3814 BALLROOM TRANE VCWF 12 1280 385 VAV -3815 SPA LOCKERS TRANE VCWF 14 1525 490 VAV -3B16 LOCKERS 319/320 TRANE VCWF 10 825 250 VAV -3817 HUMAN RES TRANE VCWF 08 470 140 VAV -31318 UNIFORM ISSUE TRANE VCWF 08 530 160 VAV - 3BIS SPA TRANE VCWF 10 1015 305 VAV -3820 H.R. MANAGER TRANE VCWF 05 245 75 VAV -581 BAR TRANE VCWF 12 1450 435 v a i r4 MW o If all"t �� 0 40 v a i r4 MW o If all"t �� 0 40 ENVIRONMENTAL FAN SCHEDULE CODE MANUFACTURER/ MODEL NO, SERVICE LOCATION TYPE CFM ESP 'WIC, (ALT,) ELECTRICAL WEIGHTS (LBS) REMARKS DRIVE HP /W VOLT PH FLA DISC, FEEDER FUSE MTG CTRL EF -1 COOK GC -120 RESTROOM EXHAUST GUEST ROOM INLINE 50 0,15 D 12,6w 120 1 0,11 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 VIII 13 A,C,B EF -lAl COOK 54XMWH GARAGE A GARAGE INLINE 13,860 0,625 B 5 208 3 163 30A /3P 3 #12, 1 #12G, 3/ *4'C 25A FRN -R 1 V 200 F,C EF -IA2 COOK 54XMWH GARAGE A GARAGE INLINE 13,860 0,625 B 5 208 3 16,7 30A /3P 3 #12, 1 #12G, 3/ *4'C 25A FRN -R 1 V 200 A,C EF -lBl COOK 6OXMWH GARAGE B GARAGE INLINE 17,430 0.625 B 5 208 3 16,7 30A /3P 3 #12, 1 #12G, 3/ )K4'C 25A FRN -R 1 V 1210 A,C EF -lB2 COOK 60XMWH GARAGE B GARAGE INLINE 17,430 0,625 B 5 208 3 16,7 30A /3P 3 #12, 1 #12G, 3 / *4'C 25A FRN -R 1 V 210 F,C EF -2A1 COOK 54XMWH GARAGE A GARAGE INLINE 13,860 0,625 B 5 208 3 16,7 30A /3P 3 #12, 1 #12G, 3/ *4 "C 25A FRN -R 1 V 200 A,C EF -2A2 COOK 54XMWH GARAGE A GARAGE INLINE 13,860 0,625 B 5 208 3 16,7 3OA /3P 3 #12, 1 #12G, 3/04 "C 25A FRN -R 1 V 200 A,C EF -2A3 COOK GN120 POOL POOL EQUIP ROOM INLINE 50 0,15 D 21,6W 120 1 012 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 13 A,C,B EF -2B1 COOK 100SQND ELECTRIC ROOM CEILING INLINE 700 0.375 B 1/6 120 1 4.4 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 XIl 90 A,C EF -2B2 COOK 100SQNB RESTROOMS CEILING INLINE 1100 0.5 B 1/2 120 1 918 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C - 1 II 90 A,C EF -3A1 COOK GN -620 SKI STORAGE CEILING INLINE 375 0,25 D 162w 120 1 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 VIII 35 C EF -3B1 COOK 100SQNB SPA RESTROOMS CEILING INLINE 1245 0.5 B 1/2 120 1 9,8 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 90 A,C EF -3B2 COOK 135SQNB ELEVATOR EQUIP ROOM CEILING INLINE 1325 0,5 B 1/3 120 1 1 72 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 135 A,C EF -3B3 COOK 80SQNB EMPLOYEE LOCKERS CEILING INLINE 860 0.5 B 1/2 120 1 918 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 90 A,C EF -3B4 PANASONIC DBF4XL RESIDENTIAL DRYER CEILING INLINE 130 0,25 D 75w 120 1 0,6 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C EF -4B1 COOK 100SQND RESTROOMS CEILING INLINE 700 0.375 D 1/6 120 1 4,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 90 A,C,B EF -5B1 COOK IOOSQN15D ELECTRIC ROOM ABOVE CLG SQUARE INLINE 700 0,5 D 1/6 120 1 16,7 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3 /4'C 1 XII 100 A,C,B EF -5B2 COOK 180QMX LOADING DOCK ABOVE CLG INLINE 10,000 0,5 B 5 208 3 1 16,7 30A/3P 3 #12, 1 ##12G, 3/ )K4'C 25A FRN -R 1 V 416 AX EF -6B1 COOK 180SQIB CHILLER EMER EXHAUST CHILLER ROOM I14LINE 3200 /450 0,5 VFD 1 480 3 3 30A /3P 3 #12, 1 #12G, 3/ )K4'C 6A FRN -R 1 X 250 A,C,G EF -8Al COOK 150SQI -HP GUEST ROOMS ROOF INLINE 250 0,4 B 1/6 120 1 4,4 2OA /SP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 - 175 A,C EF -BA2 COOK 150SQI -HP GUEST ROOMS ROOF INLINE 250 0,4 B 1/6 120 1 0,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 Il 176 A,C EF -SA3 COOK 90SQIB GUEST ROOMS ROOF INLINE 550 0,4 B 1/6 120 1 4,4 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 15 A,C EF -9A1 COOK 90SQIB GUEST ROOMS ROOF INLINE 550 0.4 B 1/6 120 1 1 4,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 175 A,C EF -9A2 COOK 90SQIB GUEST ROOMS ROOF INLINE 550 0,4 B 1/6 120 1 4,4 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C EF -9A3 COOK 90SQIB GUEST ROOMS ROOF INLINE 650 0,4 B 1/6 120 1 4.4 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4 "C 1 II 125 A,C EF -9A4 COOK 90SQIB GUEST ROOMS ROOF INLINE 750 0.4 B 1/6 120 1 4,4 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C EF -9A7 COOK 120SQIB GUEST ROOMS ROOF INLINE 900 0,4 B 1/6 120 1 4,4 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 125 A,C EF -9B1 COOK 90SQIB GUEST ROOMS ROOF INLINE 600 0.4 B 1/6 120 1 4,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C EF -9B2 COOK 135SQI -HP GUEST ROOMS ROOF INLINE 400 0,4 B 1/6 120 1 4.4 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4 - C 1 II 125 A,C EF -9B3 COOK 90SQIB GUEST ROOMS ROOF INLINE 700 0.4 B 1/6 120 1 4.4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 125 A,C EF -9B4 COOK 90SQIB GUEST ROOMS ROOF INLINE 700 0.4 B 1/6 120 1 4.4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 125 A,C EF -9B6 COOK GN180 GUEST ROOMS ROOF INLINE 200 0.4 D 111w 120 1 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 175 A,C EF -10A1 COOK 150SQI -HP GUEST ROOMS ROOF INLINE 350 0,4 B 1/6 120 1 4,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4 "C 1 II 125 A,C EF -10A3 COOK 90SQIB GUEST ROOMS ROOF INLINE 650 0,4 B 1/6 120 1 4,4 2OA /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C EF -10A4 COOK 90SOIB GUEST ROOMS ROOF INLINE 500 0,4 B 1/6 120 1 4,4 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C -10A6 COOK 90SQIB GUEST ROOMS ROOF INLINE 550 0,4 B 1/6 120 1 4,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C Ef -10A7 COOK 90SOIB GUEST ROOMS ROOF INLINE 500 0.4 B 1/6 120 1 4.4 20A /1P THERMAL OVERLOADS 2 #12, 1 #12G, 3/4'C 1 II 125 A,C I EF EF -10A9 COOK 90SQIB GUEST ROOMS ROOF INLINE 500 0,4 B 1/6 120 1 4,4 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C EF-10BI COOK 90SQIB GUEST ROOMS ROOF INLINE 550 0,4 B 1/6 120 1 4,4 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C,B -1022 COOK GN180 GUEST ROOMS ROOF INLINE 200 0,4 D 111w 120 1 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 Il 175 A,C,B EF -10B3 COOK 90SQIB ELECTRICAL CLQSESTS COOLING TOWER INLINE 1000 0,6 B 1/3 120 1 72 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 125 A,C,B EF -1181 GOOK 90SQIB GUEST ROOMS ROOF INLINE 600 0,4 B 1/6 120 1 4.4 2OA /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4 "C 1 II 125 A,C EF -1123 I EF COOK 90SQIB GUEST ROOMS ROOF INLINE 850 0.4 B 1/6 120 1 4,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 Il 125 A,C,B EF -11B5 COOK 90SQIB GUEST ROOMS ROOF INLINE 450 0,4 B 1/6 120 1 4.4 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 125 A,C,B EF -1186 COOK 135SQI -HP GUEST ROOMS ROOF INLINE 400 0,4 B 1/6 120 1 4,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 150 A,C,B EF-llB7 COOK 90SQIB GUEST ROOMS ROOF INLINE 800 0,4 B 1/6 120 1 4,4 2OA /IP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 II 125 A,C,B EF -11BB COOK 90SQIB GUEST ROOMS ROOF INLINE 450 0,4 B 1/6 12.3 1 4,4 2OA /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4 "C 1 11 125 A,C,B EF -1189 COOK 135SQI -HP GUEST ROOMS ROOF INLINE 400 0,4 B 1/6 120 1 4,4 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 11 150 A,C,B SEF -5A1 COOK 245 SQIB SMOKE EXHAUST LOBBY ROOF INLINE 11,300 0,6 B 5 208 3 16,7 30A/3P 3 #12, 1 #12G, 3/ *4 "C 25A FRN -R 1 IX 375 A,G,C SEF -7A1 COOK 225QMX ATRUIM A ATRUIM A INLINE 16,250 0,5 B 7.5 208 3 242 30A /3P 3 #10, 1 #10G, 3/ *4'C 25A FRN -R 1 IX 632 A,G,C SEF -7A2 COOK 225QMX ATRUIM A ATRUIM A INLINE 16,250 0,5 B 7,5 208 3 1242 30A /3P 3 #10, 1 #10G, 3/0C' 25A FRN -R 1 IX 16 32 A,G,C SEF -7A3 COOK 225QMX ATRUIM A ATRUIM A INLINE 16,250 05 B 7,5 208 3 24,2 3OA /3P 3 #10, 1 #10G, 3/ )K4'C 25A FRINI -R 1 IX 632 A,G,C SEF -7A4 COOK 225QMX ATRUIM A ATRUIM A INLINE 16,250 0,5 B 75 208 3 124.2 30A /3P 3 #10, 1 #10G, 3/ *4'C 25A FR # -R 1 IX 632 A,G,C SF -4A1 COOK 225 CPS -A ATRIUM SUPPLY LOBBY UTILITY SET $ 016 B 3 480 3 4.8 3OA /3P 3 #12, 1 #12G, 3/ )K4'C 6A FRN -R 2 IX .319 A,G,C SF -4A2 COOK 225 CPS -A ATRIUM SUPPLY LOBBY UTILITY SET 8 0,6 B 3 480 3 4,8 30A /3P 3 #12, 1 #12G, 3/ )K4'C 6A FRN -R 2 IX 319 A,G,C SF -3B1 COOK 202QMX ATRIUM SUPPLY LOBBY ROOF INLINE 12,500 0.8 B 5 208 3 16,7 30A /3P 3 #12, 1 #12G, 3/ *4 25A FRN -R 2 IX 1513 A,G,C SF -3B2 COOK 202QMX ATRIUM SUPPLY LOBBY ROOF INLINE 12,500 018 B 5 208 3 16,7 3OA /3P 3 ##12, 1 #12G, 3/ *4'C 25A FRN -R 2 IX 513 A,G,C SF -3B3 COOK 202QMX ATRIUM SUPPLY LOBBY ROOF INLINE 12,500 0,8 B 5 208 3 16,7 30A /3P 3 #12, 1 #12G, 3/ *4'C 25A FRN -R 2 IX 513 A,G,C SF -3B4 COOK 202QMX ATRIUM SUPPLY LOBBY ROOF INLINE 12,500 018 B 5 208 3 16.7 3OA /3P 3 #12, 1 #12G, 3/ )K4 "C 25A FRN -R 2 IX 513 A,G,C SF -6B1 COOK 330QMX ATRIUM B ATRIUM B INLINE 35,000 0.4 B 10 480 3 14 30A /3P 3 #12, 1 #12G, 3/ *4'C 20A FRN -R 2 IX 1340 A,G,C SF -6B2 COOK 330QMX ATRIUM B ATRIUM B INLINE 35,000 0,4 B 10 480 3 14 1 3OA /3P 3 #12, 1 #12G, 3/ )K4'C 20A FRN -R 2 IX 11340 A,G,C EF -KI COOK 180QMX BANQ KITCH 215 ISLAND ABOVE CLG MIXED FLOW 5950 2,75 B 75 480 3 11 30A /3P 3 #12, 1 #12G, 3/ *4'C 15A FRN -R 2 IX 416 D EF -K2 COOK 165QMX BANQ KITCH 215 CANOPY ABOVE CLG MIXED FLOW 5640 2,75 B 7.5 480 3 11 3OA /3P 3 #12, 1 #12G, 3 / *4'C 15A FRN -R 2 IX 367 D EF -K3 COOK 180QMX SHOW KITCH 423 ISLAND ABOVE CLG MIXED FLOW 6840 2,75 B 7,5 480 3 11 3OA /3P 3 #12, 1 #12G, 3/ *4'C 15A FRN -R 2 IX 416 D EF -K4 COOK 14CVB SHOW KITCH 423 CANOPY ABOVE CLG MIXED FLOW 1330 2,50 B 2 480 3 3.4 30A /3P 3 #12, 1 #12G, 3 /x4'C 6A FRN -R 2 IX 81 D EF -K5 COOK 180QMX MAIN KITCH 432 CANOPY ABOVE CLG MIXED FLOW 6230 2,75 B 7.5 480 3 11 30A /3P 3 #12, 1 #12G, 3/ )K4'C 15A FRN -R 2 IX 1416 D EF -K6 TJERNLAND NO, I -10' BANQ KITCH 215 PIZZA OVEN ABOVE CLG DRAFT INDUCER 625 0,14 D 1/4 120 1 5,8 2OA /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 2 XIII 30 EF -Dl COOK 10OSDB BANQ DISHWASH 221 ABOVE CLG INLINE 600 0,87 B 1/4 120 1 5.8 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 XI 75 B, F EF -D2 COOK 10OSDB MAIN KITCH DISHWASH ABOVE CLG INLINE 600 0,87 B 1/4 120 1 5,8 1 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 XI 75 B, F EF -Ll COOK 1500MX LAUNDRY LINT COLLECTOR ABOVE CLG MIXED FLOW 6200 1,25 VFD 5 460 3 7.6 3OA/3P 3 #12, 1 #12G, 3/ )K4'C 10A FRN -R 2 XIII 416 E EF -GS COOK DBX --10 GENERAT SUSP IN -LINE 1800 0,50 B 0,5 120 1 9.8 20A /lP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 XIII 80 A,C CAF -1 EXHAUST❑ MCAS 500 BOILER ROOM BOILER ROOM UTILITY SET 5,500 1 VFD 3 480 3 42 30A /3P 3 #12, 1 #12G, 3/ *4'C 6A FRN -R 4 1 250 CAF -2 EXHAUSTO MCAS 500 BOILER ROOM BOILER ROOM UTILITY SET 5,500 1 VFD 3 480 3 4,8 30A /3P 3 #12, 1 #12G, 3/ )K4'C 6A FRN -R 4 1 250 GENER 1. DRIVE TYPEi D= DIRECT- PROVIDE RHEOSTAT SPEED CONTROLLER IN FAN HOUSING UNLESS OTHERWISE NOTED. B -BELT- PROVIDE ADJUSTABLE SHEAVE UNLESS OTHERWISE NOTED, VFD= VARIABLE FREQUENCY DRIVE. 2, ALL CURBS SHALL BE FACTORY MADE, 14 INCH HIGH INSULATED UNLESS OTHERWISE NOTED, 3, SCHEDULED FAN VALUES (CFM, SP AND HP) ARE ACTUAL AT ALTITUDE. MOTOR HP HAS BEEN ADJUSTED FROM SEA LEVEL CONDITIONS FOR OPERATION AT JOBSITE ELEVATION, JOBSITE ELEVATION = 8200FT. 4, PROVIDE MAGNETIC STARTER WITH AUXILARY CONTACTS AND HOA SWITCH ON ALL THREE PHASE UNITS EXCEPT WHEN SERVED FROM MOTOR CONTROL CENTER, 5, PROVIDE HIGH EFFICIENCY MOTORS, (RELIANCE E+ OR EQUIVALENT) MOUN 1, INSTALL FAN WITH FLEXIBLE CONNECTIONS AT DUCT INLET AND OUTLET AND WITH HANGING VIBRATION ISOLATORS, 2,PROVIDE WITH FACTORY MANUFACTURED ROOF CURB SUITABLE FOR ROOFING SYSTEM BEING USED, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. ALSO PROVIDE FACTORY BACKDRAFT DAMPER, 3, MOUNT INLINE OF EXHAUST FLUE. 4. HANG FROM STRUCTURAL ABOVE WITH VIBRATION ISOLATORS, QQNTRUL TR I, INTERLOCK WITH HVAC UNIT WHICH SERVES SAME SYSTEM (VIA DDC SYSTEM). II. RUN CONTINUOUSLY, CONTROL VIA DDC SYSTEM, III. CONTROL VIA WALL SENSOR - ENERGIZE AT 75F (ADJUSTABLE), IV, CONTROL VIA WALL SENSOR - INTERLOCK WITH UNIT THAT SERVES SAME AREA, ENERGIZE FAN AND MOTORIZED DAMPER, DE- ENERGIZE FAN, CLOSE DAMPER AND UNIT OPERATION, LOCKOUT FIRST STAGE OF COOLING (FAN) WHEN OUTSIDE AIR TEMPERATURE IS EQUAL OR GREATER THAN SPACE SETPOINT =78,5F (ADJUSTABLE), V, ENERGIZE FAN AND OPEN MOTORIZED DAMPER ON RISE IN CO LEVEL. SEE SPECIFICATIONS, MONITOR VIA DDC SYSTEM, VI, ENERGIZE VIA MANUAL WALL SWITCH . NO DDC INTERFACE, VII, ENERGIZE VIA MANUAL WALL SWITCH, PROVIDE DDC SYSTEM MONITORING, VIII, ENERGIZE VIA TIMECLOCK, IX. SEE DIV 15950, 'SEQUENCE OF OPERATION ' SECTION, X, CONTROL VIA THERMOSTAT AT LOW SPEED, REFRIGERANT SENSOR ACTIVATES HIGH SPEED, XI, INTERLOCK WITH KITCHEN DISHWASHER WITH 0 TO 60 MIN DELAY. XII, CONTROL VIA WALL MOUNTED THERMOSTAT SET AT 85F (cad,,) XIII, CONTROL VIA PRESSURE SWITCHi PROVIDE ALARM VIA BAS. REMARK NOTES A, PROVIDE BELT AND MOTOR GUARD. B. PROVIDE SPEED CONTROL SWITCH, C. PROVIDE GRAVITY BACKDRAFT DAMPER, D, KITCHEN EXHAUSTER SHALL BE UL 762 LISTED FOR RESTAURANT APPLICATIONS, PROVIDE GREASE DRAIN, MOTOR HEAT SHIELD, RATED ACCESS DOOR, HIGH TEMP BEARINGS, HIGH TEMP PAINT, BELT TUNNEL, AND ALL ACCESSORIES REQUIRED TO COMPLY WITH NFPA 96, E, HEAT SHIELD /HIGH TEMPERATURE PAINT, F, 2 -SPEED CONTROL. G, CONNECT TO EMERGENCY POWER, M -E ENGINEERS, INC. OOtfB E. BEAVER CREEK 811. SURE 307 A.o. BoX X40 AVON, Co. 6 1(20 PH: 670) 941-000 FAX: 6?0) 141-1951 i 1 I II COOLING TOWER SCHEDULE M D ESIGN ELECT MODEL NO, • r • r . r . R s i i i i •- •t ii •i �.� a ,. i 1. PROVIDE HIGH EFFICIENCY MOTORS (RELIANCE E+ OR EQUIVALENT), 2, PROVIDE MAGNETIC STARTERS WITH AUXILIARY CONTACTS AND HOA SWITCH ON ALL THREE MOTORS, 3. SEE SPECIFICATIONS FOR VIBRATION ISOLATION. 4, TOWER TO BE CTI RATED, PROVIDE 2 SPEED MOTORS PROVIDE BASIN HEATERS WITH NECESSARY CONTROLS TO MAINTAIN 40F WATER TEMPERATURE, PROVIDE LADDERS AND RAILINGS, PROVIDE MOTOR OUTSIDE OF AIRSTREAM, PROVIDE DISCHARGE HOOD WITH DAMPER. PROVIDE CONTROL PANEL WITH SINGLE POINT ELECTRICAL CONNECTION TO CONTROL FAN OPERATION AND BASIN HEATERS. PROVIDE ELECTRONIC FLOAT AND MAKEUP VALVE, LOW I NTENSIT Y INF RARED TUBE HEATER CODE (IF) MANUFACTURER/ MODEL NO, (HYDRONIC) RADIANT SURFACE CAPACITY GPM/ URNER CAPACI Y ELE CTRICAL MOUNTING HEIGHT REMARKS LENGTH CONFIGURATION SURFACE AREA MANUFACTURER/ MODEL NO. OUTPUT GAS VOLT PH DISC FUSE FEEDER FLA (FT) VULCAN LINOVECTOR (SQ FT) q1NPUT @ALTITUDE P RESS. 5B1 SOLARONICS GQG- 150 -40CN 40 20' ANGLE 41,9 HP 120 7' 115 1 20A /1P THERMAL OVERLOAD FEEDER 2 #12, #12G, 3/4'C 15,0 16' AFF A,B,C 5B2 SOLARONICS GQG - 150 -40CN 40 30' ANGLE 41,9 208 120 1 7' 115 1 1 20A /1P THERMAL OVERLOAD 6A 2 #12, #12G, 3/4'C 15,0 1 16' AFF A,B,C PROVIDE WALL MOUNTED THERMOSTAT, PROVIDE HIGH WIND INSTALLATION 4' INDOOR VENT KIT Iii BASEBOARD RADIATION SCHEDULE CHYDRONIC7 CABINET /UNIT HEATER SCHEDULE (HYDRONIC) MANUFACTURER/ CAPACITY GPM/ CODE MODEL NO, (BTUH /LF) CODE ROWS MANUFACTURER/ MODEL NO. AREA SERVED CONFIG CAP, (MBH) CFM ELEC GPM RICAL Mawkm BBR -1 VULCAN LINOVECTOR 'i 0.09 1 B,D CONN, SIZE WEIGHT <LBS) REMARKS HP VOLT PH FLA DISC FUSE FEEDER UH -1A1 TRANE MODEL S 400 -W2 GARAGE A HORIZONTAL 270 5000 223 3/4 208 3 3.5 � 30A/3P COM{tiUiiii aA TIONS 6A FRS -R 3 #12, 1 #12G 3/4'C II UH -IA2 TRANE MODEL S 400 -W2 GARAGE A HORIZONTAL P7T 6000 22,3 3/4 208 3 3,5 30A /3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH -1A3 TRANE MODEL S 400 -W2 GARAGE A HORIZONTAL 270 6000 22.3 3/4 208 3 3.5 3OA /3P 6A FRS -R 3 #12, 1 #12G 3/4'C PR OVIDE !• UH -1A4 TRANE MODEL S 400 -W2 GARAGE A HORIZONTAL 270 6000 223 3/4 208 3 3,5 3OA /3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH -1B1 TRANE MODEL S 400 -W2 GARAGE B HORIZONTAL 270 6000 22.3 3/4 208 3 315 3OA /3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH -32 TRANE MODEL S 400 -W2 GARAGE B HORIZONTAL 270 6000 22.3 3/4 208 3 315 3OA /3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH -2A1 TRANE MODEL S 400 -W2 GARAGE A HORIZONTAL 270 6000 22,3 3/4 208 3 3.5 30A /3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH - -'2A2 TRANE MODEL S 400 -W2 GARAGE A HORIZONTAL 270 6000 223 3/4 208 3 3,5 3OA /3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH -2A3 TRANE MODEL S 400 -W2 GARAGE A HORIZONTAL 270 6000 22.3 3/4 208 3 3.5 30A/3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH -2A4 TRANE MODEL S 400 -W2 GARAGE A HORIZONTAL 270 6000 22.3 3/4 208 3 3,5 3OA /3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH -2A5 TRANE MODEL S 18 -S CHEMICAL STORAGE HORIZONTAL 1 50 0.1 1/50 120 1 1,1 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C UH -2B1 TRANE MODEL S 400 -W2 MECH ROOM HORIZONTAL 60 1100 1,8 3/4 208 3 3.5 30A /3P 6A FRS -R 3 #12, 1 #12G 3/4'C UH -4B1 VULCAN HV -125A LOADING DOCK VERTICAL 25 580 2.5 1 /20 120 1 111 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C UH -4B2 VULCAN HV -125A LOADING DOCK VERTICAL 25 580 2,5 1/20 120 1 1.1 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C CUH -1A1 TRANE MODEL N 020 GARAGE A STAIR HORIZONTAL 5 250 1,11 1/15 120 1 2,2 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, CUH -1B1 TRANE MODEL D 020 GARAGE EL£V LOBBY VERTICAL 17 135 1,11 1/15 1-20 1 212 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C CUH -1B2 TRANE MODEL N 020 GARAGE B STAIR HORIZONTAL 5 250 1.11 1/15 120 1 212 20A /1P THERMAL OVERLOAD 2 #12, 1 112G, 3/4'C CUH -2B1 TRANE MODEL 020 STAIRWELL VERTICAL 16 185 13 1/3 120 1 7.2 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C CUH -2B2 TRANE MOREL 020 GARAGE VEST VERTICAL 10 150 1 1/3 120 1 7.2 20A /1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C CUH -4B1 TRANE MODEL 020 BUS UNLOADING VEST VERTICAL 10 150 1 1/3 120 1 7,2 20A/1P THERMAL OVERLOAD 2 #12 1 #12G 3 /4'C GENERAL NOTES 1, EAT= -10F, LAT =95F. 2, HEATING WATER EWT =160F, LWT =140F, 30% PROPYLENE GLYCOL, A. PROVIDE UNIT MOUNTED THERMOSTAT WITH SPEED CONTROL SWITCH, B. PROVIDE 24VDC CONTROL TRANSFORMER. Iii CONDENSING UNIT SCHEDULE (ADD ALTERNATE) SYMBOL NOMINAL VOLTS /PHASE MCA MOCP OPER. WT. MAKE AND NOTES TONS (LBS) MODEL IwC.frt COOLING A B CU -1 3 208 / 3 -- - 350 LI£BERT 1,2,3 2 PFH037A -YL 4, 6 UNEML OMMENTI 1. CAPACITIES ARE AT 8200 FT. ELEVATION. 2. ANCHOR CONDENSING UNIT TO SLEEPERS /CURB. 3. FIELD !ABEL FAN COIL TO AREAS SERVED. NOTE A. ACCESSORIES 1. PRE - CHARGED REFRIGERANT LINE SETS, SIZED BY MANUFACTURER. 2. SHORT- -CYCLE TIMER. 3. LOW - AMBIENT COOLING TO 0' F. 4. SUCTION ACCUMULATOR. 5. HAIL GUARD 6. HOT GAS BYPASS B. FAN SPEED SETTING 7. OIL SEPARATOR. 1. UNIT CFM TO BE SET ON LOW SPEED. 8. FILTERS: FARR 2"-30/30 2. UNIT CFM TO BE SET ON HIGH SPEED. 9. ELECTRIC HEATER 10, MIXING BOX PLENUM BY MANUFACTURER 11. CRANKCASE HEATER 12. MANUFACTURERS THERMOSTAT. 13. 1" DEFL. SPRING AND NEOPRENE ISOLATORS. BASEBOARD RADIATION SCHEDULE CHYDRONIC7 COM ROO MANUFACTURER/ CAPACITY GPM/ CODE MODEL NO, (BTUH /LF) FT ROWS REMARKS ti MANUFACTURER/ ' Mawkm BBR -1 VULCAN LINOVECTOR 'i 0.09 1 B,D - MODEL NO.----- AREA SERVED GENERAL 1. NOTES EWT= 178 F, LWT= 153 F, 30% PROPYLENE GLYCOL, 2, MINIMUM FLOW FOR CIRCUIT IS 1 GPM. 3, PROVIDE WALL TO WALL ENCLOSURE UNLESS OTHERWISE NOTED, 4, ENCLOSURE COLOR SELECTED BY ARCHITECT, 5, TUBE MATERIAL IS COPPER, FIN MATERIAL ALUMINUM UNLESS OTHERWISE NOTED, � L IEBERT 46 C COM{tiUiiii aA TIONS NO ENCLOSURE BARE ELEMENT ONLY, ARCHITECT TO PROVIDE ENCLOSURE. i I i �.`iL`' • i ��� II ���� i • w O * :. t 1 1, CHILLED WATE.Ri EWT=46 F, LWT= 58 F, 30% PROPYLENE GLYCOL. J OBSITE ELEVATI // RE_M PR OVIDE !• CONDENSING UNIT SCHEDULE (ADD ALTERNATE) SYMBOL NOMINAL VOLTS /PHASE MCA MOCP OPER. WT. MAKE AND NOTES TONS (LBS) MODEL IwC.frt COOLING A B CU -1 3 208 / 3 -- - 350 LI£BERT 1,2,3 2 PFH037A -YL 4, 6 UNEML OMMENTI 1. CAPACITIES ARE AT 8200 FT. ELEVATION. 2. ANCHOR CONDENSING UNIT TO SLEEPERS /CURB. 3. FIELD !ABEL FAN COIL TO AREAS SERVED. NOTE A. ACCESSORIES 1. PRE - CHARGED REFRIGERANT LINE SETS, SIZED BY MANUFACTURER. 2. SHORT- -CYCLE TIMER. 3. LOW - AMBIENT COOLING TO 0' F. 4. SUCTION ACCUMULATOR. 5. HAIL GUARD 6. HOT GAS BYPASS B. FAN SPEED SETTING 7. OIL SEPARATOR. 1. UNIT CFM TO BE SET ON LOW SPEED. 8. FILTERS: FARR 2"-30/30 2. UNIT CFM TO BE SET ON HIGH SPEED. 9. ELECTRIC HEATER 10, MIXING BOX PLENUM BY MANUFACTURER 11. CRANKCASE HEATER 12. MANUFACTURERS THERMOSTAT. 13. 1" DEFL. SPRING AND NEOPRENE ISOLATORS. 0049 E. BEAVEt CUXK MD. WTE 307 P.D. $O1fi 5740, AVON, CO. $1620 PH: MO) 141-6000 PAX. MO) 141-1151 I'm BASEBOARD RADIATION SCHEDULE CHYDRONIC7 MANUFACTURER/ CAPACITY GPM/ CODE MODEL NO, (BTUH /LF) FT ROWS REMARKS BBR -1 VULCAN LINOVECTOR 1100 0.09 1 B,D GENERAL 1. NOTES EWT= 178 F, LWT= 153 F, 30% PROPYLENE GLYCOL, 2, MINIMUM FLOW FOR CIRCUIT IS 1 GPM. 3, PROVIDE WALL TO WALL ENCLOSURE UNLESS OTHERWISE NOTED, 4, ENCLOSURE COLOR SELECTED BY ARCHITECT, 5, TUBE MATERIAL IS COPPER, FIN MATERIAL ALUMINUM UNLESS OTHERWISE NOTED, A. PROVIDE OUTLET DAMPERS, B, NO ENCLOSURE BARE ELEMENT ONLY, ARCHITECT TO PROVIDE ENCLOSURE. C, INTERLOCK CONTROL WITH - - - - - -, D. MOUNTING HEIGHT= 10', 0049 E. BEAVEt CUXK MD. WTE 307 P.D. $O1fi 5740, AVON, CO. $1620 PH: MO) 141-6000 PAX. MO) 141-1151 I'm RUMS' SCHEDULE (HYDRONIC) MANUFACTURER/ MODEL NO. CAP. ! .. DA CODE MANUFACTURER / MODEL NO. SERVICE STORAGE GALS RECOVERY GPH HEATIWS WATER DOM. HOT WATER WEIGHT CODE MANUFACTURER/ MODEL NO. SERVICE LOCATION PUMP TYPE EWT F GPM HEAD FT NPSHR FT RPM THERMAFLOW TH- 750- 1036DW GUEST ROOM DOMESTIC WATER 57 ELECTRICAL RISE 95 180 140 5 38 WEIGHT LBS REMARKS HP VOLT PH FLA FUSE DISCON. FEEDER WATER CHWP -1,2 B & G VCS 5X5X9 -3 4 8 PRIMARY CHILLED WATER 95 SPLIT CASE 140 ' 500 35 40 10 460 3 14.0 20A FRS —R 30A 3P 3 12, 1 12G, 3/4"C — 515 -- -- CHWP --3,4 B & G VCS 5X5X9 -3 4 8 SECONDARY CHILLED WATER -- SPLIT CASE D 600 55 GUEST ROOM DOMESTIC WATER 40 460 3 52.0 70A FRS —R 10OA 3P 3 #4, 1 8G, 1-1/4"C -- 590 D CHWG --1 HWP -1,2 8 & G VCS 6X6X9 -3 4 L HEATING WATER 155 SPLIT CASE RISE 690 30 160 2,9 7.5 460 3 11.0 15A FRS —R 30A 3P 3 10, 1 10G, 3/4 15003 120' 540 156 180 HWP -3,4 B & G VCS 6X6X9 -3 4 B HEATING WATER SPLIT CASE 690 50 A,B,C CST -1 50 460 3 65.0 90A FRS —R 100A 3P 3 -- f8G, 1-1/2"C 630 — CWP -1,2 B & G 6X8X9 -3 4 H CONDENSER WATER SHIPPED FULLY ASSEMBLED. SPLIT CASE 1050 30 15 460 3 21.0 30A FRS —R 30A 3P 3 10, 1 10G, 3/4 885 SMP -1,2 B & G 1510 1-1/213C SNOWMELT END SUCTION 120 80 1750 5 460 3 7.6 10A FRS —R 3OA 3P 3 12, 1 12G, 3/4"C 210 SOP -1,2 ITT FLYGT CP3045,180 SAND INTERCEPTOR "A" BELOW GRADE SUBMERSIBLE NON —CLOG 20 37 3600 1.8 460 3 2.4 6A FRS —R 3OA 3P 3 12, 1 12G, 3 4 85 F,G,I SOP -3,4 ITT FLYGT CP3045.180 SAND INTERCEPTOR „ B" BELOW GRADE SUBMERSIBLE NON —CLOG 20 37 3600 1.8 460 3 2.4 6A FRS —R 30A 3P 3 12, 1 12G, 3/4 85 F,G,I SP --1,2 ITT FLYGT CP3068.180 SANITARY WASTE "A" BELOW GRADE SUBMERSIBLE: NON —CLOG 100 39 3500 2.7 460 3 3.6 6A FRS —R 30A 3P 3 12, 1 12G, 3/4 1101 F,G,I SP -3,4 ITT FLYGT CP3127.180 SANITARY WASTE „B„ BELOW GRADE SUBMERSIBLE NON —CLOG 450 42 11.7 1750 10 460 3 13.0 20A FRS —R 30A 3P 3 12, 1 12G, 3 4 405 F,G,I STP -1,2 ITT FLYGT NP3127.180 STORM WATER "A" BELOW GRADE SUBMERSIBLE NON —CLOG 470 39 12.7 1750 7.5 460 3 9.6 15A FRS —R 30A 3P 3 # 12, 1 12G, 3/4 405 F,G,I STP -3,4 ITT FLYGT NP3127.180 STORM WATER "B" BELOW GRADE SUBMERSIBLE NON —CLOG 586 39 12.8 17501 10 460 3 13.0 20A FRS —R 30A 3P 3 12, 1 12G, 3 4 420 F,G,I KP -1,2 ITT FLYGT CP3068.1801 KITCHEN CLARIFIED WASTE "B" BELOW GRADE SUBMERSIBLE NON —CLOG 100 39 3600 2.7 460 3 3.6 6A FRS —R 30A/31? 3 # 12, 1 #12G 3/4"C 110 F,G,I SDP -1,2 ITT FLYGT NP3171.180 FOUNDATION SUB —DRAIN „ B" BELOW GRADE SUBMERSIBLE NON —CLOG 1500 42 24.3 1750 25 460 3 30.0 45A FRS —R 60A 3P 3 6, 1 J10G, 3/4 865 F,G,I CDHWP -1,2 B &G SERIES 80 3x3x7B COMM. HOT WATER GEN. "B" RM 2072 IN —LINE 155 18 4.8 1750 1.5 460 3 3.0 6A FRS —R 30A 3P 3 12, 1 12G, 3/4"C 195 H,I GDHWP-1,2 B &G SERIES 801 236x2 -%x7 GUEST HOT WATER GEN. "B" RM 202 IN —LINE 95 20 3.1 1750 1 460 3 2.1 3A FRS- -R 30A 3P 3 12, 1 12G, 3/4 215 H,I CDHWRP -1,2 B &G PL -45 COMM. DOM. HOT WATER RETURN "B" RM 2072 IN —LINE 12 42 3250 0.4 120 1 0.8 20A/1 P THERMAL OVERLOAD 2 12, 1 12G, 3 4 9.5 A,I GDHWRP -1,2 B &G SERIES 60 1 %x 1 hx7 GUEST DOM. HOT WATER RETURN "B" RM 202 IN —LINE 30 54 1750 2 460 3 20A 1 P THERMAL OVERLOAD 2 12, 1 J12G, 3/4"C 14.5 A,I GENERAL 1. 2. 3. 4. 5. A. B. C. D. E. F. G. H. I. UOTE PROVIDE MAGNETIC STARTER WITH AUXILIARY CONTACTS AND HOA SWITCH ON ALL THREE PHASE MOTORS. PROVIDE HIGH EFFICIENCY MOTORS. (RELIANCE E+ OR EQUIVALENT) FOR PARALLEL PUMP APPLICATIONS MANUFACTURER SHALL REVIEW SINGLE PUMP OPERATON SUCH THAT PUMP CAN OPERATE AND NOT EXCEED THE END OPERATION POINT ON THE PUMP CURVE AND MOTOR HP IS PROPERLY SLELCTED TO PREVENT OVERLOADING. NPSHR AT SCHEDULED OPERATING POINT SHALL NOT EXCEED 0.8 *NPSHR, UNLESS OTHERWISE NOTED. REFER TO DRAWINGS TO DETERMINE REQUIRED PUMP ROTATION. COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING. PROVIDE ALL BRONZE CONSTRUCTION (INLINE PUMPS). PROVIDE ALL BRONZE CONSTRUCTION (BASE MOUNT). 50% CAPACITY (PARALLEL PUMP APPLICATION). 100% STANDBY OPERATION. PROVIDE AUTOMATIC LEAD /LAG CHANGEOVER BASED ON ------- FLUID CONTAINS 30% PROPYLENE GLYCOL. ALL PUMP COMPONENTS IN CONTACT WITH THE FLUID SHALL BE COMPATIBLE 'WITH GLYCOL. ADJUST STANDARD CATALOG PERFORMANCE TO ACCOUNT FOR USE OF GLYCOL. ASSUME FLUID TEMPERATURE OF 40 F (CHWP) AND 150 F(HWP) FOR PUMP ADJUSTMENT. CAST IRON CONSTRUCTION, RAIL MOUNTED CONFIGURATION AND ACCESSPRIES. PROVIDE FLYGT CONTROL CENTER, LIQUID SENSORS (4 PER DUPLEX SETUP), CABLE HOLDER AND ALL APPURTENCES FOR LIFT STATION TYPE INSTALLATION. ASSUME FLUID TEMPERATURE OF 180' F. ALTERNATING PUMP OPERATION. DOMESTIC WATER HEATER AND STORAGE TANK SCHEDULE (HYDRONIC) MANUFACTURER/ MODEL NO. CAP. ! .. DA CODE MANUFACTURER / MODEL NO. SERVICE STORAGE GALS RECOVERY GPH HEATIWS WATER DOM. HOT WATER WEIGHT GPM EWT F LWT F P.D. PSI GPM EWT F LWT F ) (LBS) REMARKS GHWG --1 THERMAFLOW TH- 750- 1036DW GUEST ROOM DOMESTIC WATER 57 2270 100' RISE 95 180 140 5 38 40 140 940 A,B,C GHWG -2 THERMAFLOW TH- 750- 1036DW GUEST ROOM DOMESTIC WATER 57 2270 100` RISE 95 180 140 5 38 40 140 940 A,B,C GST -1 LOCHINVAR RGA650 GUEST ROOM DOMESTIC WATER 650 — -- — — -- -- — -- 7380 D GST -2 LOCHINVAR RGA650 GUEST ROOM DOMESTIC WATER 650 -- — — — -- — -- 7380 D CHWG --1 THERMAFLOW VSH-- 155 --20 -3060 COMMERCIAL DOMESTIC WATER 155 1500 1207' RISE 156 180 160 2,9 25 40 160 1450 A,B,C CHWG -2 THERMAFLOW VSH- 155 -20 -3060 COMMERCIAL DOMESTIC WATER 155 15003 120' RISE 156 180 160 2.9 25 40 160 1450 A,B,C CST -1 LOCHINVAR RGA432 lCOMMERCIAL DOMESTIC WATER 432 -- -- — -- -- _ — 48 D 1. HEAT EXCHANGER AND TANK TO BE ASSEMBLED AT THE FACTORY AND 2. MANUFACTURER TO SIZE AND PROVIDE INTRA —TANK CIRCULATOR. . HEATING WATER CONTAINS 307o PROPYLENE GLYCOL REMAEK N= A. MUST BE NSF APPROVED. B. HEAT EXCHANGER TO BE DOUBLE WALL, C. STARTUP BY FACTORY TRAINED AND AUTHORIZED PERSONNEL. D. AMSE RATED SHIPPED FULLY ASSEMBLED. CHILLER SCHE DULE - COOLED MANUFACTURER/ MODEL NO. CAP. ! .. DA ..�� � � li. � it � r _ ... �� • ! �� � i s � • ! � ! � • � �� j,�� =i � ' • j f ! � i I l.WATER CONTAINS 30% PROPYLENE GLYCOL. 2. REFRIGERANT 134x. BO SCHEDULEHYDRCNIC) CODE MANUFACTURER/ INPUT OUTPUT ELECTRICAL WEIGHT MODEL NO. MBH S.L. MBH ALT. GPM HP VOLT PH FLA FUSE DISCON. FEEDER LBS REMARKS B -1,2 UNIVERSAL OF -350W4 14,700 9,960 690 10 1 460 1 3 114-0120A FRS —R I 30A /3P 1 3 #12, 1 #12G, 3/4 "C 20,463 1. LWT= 180 F. 2. WATER CONTAINS 30% PROPYLENE GLYCOL. 3. JOBSITE ELEVATION= 8.150. 4. FUEL TYPE = NATURAL GAS. F ORCE A. DR A FT AD JUST PROVI OUTPUT AT OP ERATING ELEVATI i ATMOS B URNER. i BURNE "t! -6 WGINE.ERS, INC. � f �70 3 1 141 - 6000 th rw. $EpVr:;<;�tlt�. SURE 3177 PH: OX 5'W, AVON, M 81620? FAX: (fi 0) � 11SI LAUNDRY EQUIPMENT COORDINATION EQ ID NUMBER EQUIPMENT DESCRIPTION HP KW VOLTAGE PHASE FLA MCA FEEDERS FUSE DISC CONNECTION NOTES 9 CHEMICAL DISP. EQUIP. SERVICE 4,O 120 1 19,2 KW 2 #10,1 #I0G, 3/4'C 25A FRN -R 3OA /lP PHASE A 10 WASHER, 60 LB, 5 GROUND 208 3 17,5 ELECTRICAL OVEN /RANGE 3 #10, 1 #10G, 3/4'C 25A FRN -R 30A /3P - -- 120/240 11 WASHER, 135 LB, 10 PASSENGER 208 3 3212 3/4' 3 #6, 1 #I0G, 1'C 45A FRN -R 60A /3P GENERAL ELECTRIC - -- 13 FOLDING TABLE OUTLETS 120/240 110 1 120 1 8,33 3 2 #12, 1 #12G, 3/4'C - --- 2OA /1P THERMAL OVERLOAD NEMA 5 -20R EQ -3 14 FLOOR SCALE 110 025 120 1 2.1 BSMNT 2 #12, 1 #12G, 3/4'C 3A FRN -R 30A /1P 412 #12 16 DRYER, 75 LB. EQ -4 210 480 3 2,4 - -- 3 #12, 1 #12G, 3/4'C 3A FRS -R 30A /3P 20.0 A 17 DRYER, 150 LB. #12 4,0 480 3 4.8 GENERAL ELECTRIC 3 #12, 1 #12G, 3/4'C 6A FRS -R 3OA /3P 120 1 19 ILINT COLLECTOR 60A / 3P 110 120 1 833 NOTE 3 & 7 2 #12, 1 #12G, 3/4'C - - -- 20A / IP THERMAL OVERLOAD NEMA 5 -20R - - -- 21 IRONER /FOLDER 1 10.0 480 3 12.0 #12 3#12, 1#12G, 3/4'C 15A FRS -R 3OA /3P EQ -7 GAS FIREPLACE IGNITOR 24 TOWEL FOLDER 1 #12G, 110 480 3 12 3,0 3 #12, 1 #12G, 3/4'C 3A FRS -R 3OA /3P #12 3/4' 27 COUNTER OUTLET 1/2 0,50 120 1 4,2 - -- 2 #12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R 1 #12G, 28 TABLE OUTLETS SP -18 110 120 1 833 RM 1 2 #12, 1 #12G, 3/4 - C - - -- 20A / IP THERMAL OVERLOAD NEMA 5-208 - - -- 32 MARKING MACHINE 310 050 120 1 4.1 OVERLOAD 1 2 #12, 1 #12G, 3/4'C - - -- 20A / IP THERMAL OVERLOAD NEMA 5 -20R SP -19 33 SEWING MACHINE POOL - LIGHTS - QTY (2) 0,50 120 1 4.1 / SPA 2 #12, 1 #12G, 3/4'C - - -- 20A / IP THERMAL OVERLOAD NEMA 5 -20R 2.5 1 34 SEWING MACHINE 20A 0.50 120 1 41 3/4'C 2 #12, 1 #12G, 3/4'C - - -- 20A / IP THERMAL OVERLOAD NEMA 5 -20R 6OA /3P 35 BUTTON MACHINE 16 -A 0.50 120 1 41 1 2 #12, 1 #12G, 3/4'C - - -- 20A / IP THERMAL OVERLOAD NEMA 5 -20R - ---- 36 SEWING CABINETS 16 -B 1.4 120 1 833 PENTAIR #WFDS -8 2#12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5--208 242 37a DOMESTIC WASHER 2 110 120 1 8.33 FRN -R 2##12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R 1 #12G, 37b DOMESTIC DRYER S1 -10 -B 610 480 3 7.22 RM 3 #12, 1 #12G, 3/4'C 10A FRS -R 30A /3P EQUIP, 2 40 DRY CLEANER 132 5.O 480 3 610 3 3 #12, 1 #12G, 3/4'C 10A FRS -R 3OA /3P 4A FRN -R S1 -13 40a WATER CHILLER SPA I - CIRC. PUMP 6.0 480 3 722 / SPA 3 #12, 1 #12G, 3/4'C 10A FRS -R 30A /3P 1 7,7 40b WASTE WATER COLLECTOR 21 -B 110 120 1 8.33 3/4'C 2 #12, 1 #12G, 3/4'C - - -- 20A / IP THERMAL OVERLOAD NEMA 5 -20R SPA 1 - HEATER 42 PANT PRESS - POOL 1 0,50 120 1 4.1 3 2 #12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R 30A / 3P 43 PANT TOPPER 1 #12G, 1.0 120 1 8,33 1 2 #12, 1 #12G, 3/4'C - - -- 20A / IP THERMAL OVERLOAD NEMA 5 -20R - POOL 44 FORM FINISHER 27 110 120 1 8.33 - -- 2 #12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R 1 #12G, 45 VACUUM UNIT SI -18 1.0 120 1 8.33 RM 2 #12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R - - -- 47 SHIRT PRESS 110 0.50 120 1 4,1 OVERLOAD 2 #12, 1 #12G, 3/4'C - - -- 20A / IP THERMAL OVERLOAD NEMA 5 -20R 51 -19 48 SHIRT SLEEVE PRESS SPA 1 - LIGHTS - QTY (1) 1.0 480 3 8.33 / SPA 3 #12, 1 #12G, 3/4'C 15A FRS -R 30A /3P 1 310 49 COLLAR /CUFF /YOKE PRESS 20A 1 0,10 120 1 0.8 3/4'C 2 #12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R SPA 1 - WATER FALL PUMP 55 UNIFORM CAROUSEL 242 0,25 120 1 2.0 208 1 2 #12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R - - -- 57 UTILITY PRESS 2 #12, 0,50 120 1 4.1 1 1 2 #12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R 6OA /2P 61 FINISHING TUNNEL 40 2.25 480 3 2,7 1 1 3 #12, 1 #12G, 3/4'C 6A FRS -R 30A/3P 20A / 1P THERMAL OVERLOAD - - -- 66 FLOWER REFRIGERATOR 41 -A 110 120 1 8,33 1 1 2 #12, 1 #12G, 3/4'C - - -- 20A / 1P THERMAL OVERLOAD NEMA 5 -20R EQUIP. 67 GLASS WASHER 1 610 480 3 7.22 1 1 3 #12, 1 #12G, 3/4'C 10A FRS -R 3OA /3P 3/4'C - - -- VAIL PLAZA HOTEL RESIDENTIAL AND EMPLOYEE UNIT EQUIPMENT SCHEDULE EQUIPMENT DESCRIPTION HP VA VOLTAGE PH FLA MCA FEEDERS FUSE DISC ELEVATOR ELEVATOR TYPE SERVICE LOCATION EQUIPMENT CODE EQUIPMENT DESCRIPTION MANUFACTURER KW FUSE MOTOR HP<WATTS) VOLTAGE PHASE NOTES FLA NO. OF WIRES WIRE SIZE GROUND COND, REMARKS EQ -1 ELECTRICAL OVEN /RANGE GENERAL ELECTRIC --- 50A / 3P - -- 120/240 1 VOLT 40.0 PASSENGER 3 #8 #10 3/4' NOTE 1& 7 EQ -2 ELECTRICAL RANGE /COOKTOP GENERAL ELECTRIC - -- V - -- 120/240 1 SERVICE 40,0 ROOF 3 #8 #10 3/4' NOTE 1 & 8 EQ -3 MICROWAVE /HOOD COMBO GENERAL ELECTRIC 110 SP -10 -B - -- 120 1 BSMNT 813 480 2 412 #12 3/4' NOTE 2 & 9 EQ -4 DISHWASHER GENERAL ELECTRIC - -- 208 - -- 120 1 1 #12G, 3/4'C 20.0 SP -12 2 #12 #12 3/4' NOTE I & 7 EQ -5 REFRIGERATOR /FREEZER W/ IC£MAKER GENERAL ELECTRIC --- 208 - -- 120 1 NOTESi 1. PROVIDE ALL CIRCUITING, DISCONNECTS, THERMAL OVERLOAD SWITCHES, ETC, FOR ALL MECHANICAL EQUIPMENT, CIRCUIT ALL LINE VOLTAGE THERMOSTATS AND MOTOR OPERATORS. CIRCUIT ALL CONTROLLERS AND MOTORS. SEE ELEVATOR SHOP DRAWINGS FOR EQUIPMENT LOCATIONS, 2, CONDUCTOR SIZES INDICATED ARE COPPER THWN, 3. PROVIDE SHUNT -TRIP FUSED DISCONNECT IN NEMA 3 ENCLOSURE IN ELEVATOR MACHINE ROOM FOR EACH ELEVATOR, PROVIDE SHUNT -TRIP 120V CONTROL CIRCUIT. 4. CONDUCTOR SIZES INDICATED ARE MINIMUM. SIZE CONDUCTORS FOR A MAXIMUM OF 3 PERCENT VOLTAGE DROP. 5. PROVIDE FUSING PER ELEV. MANUFACTURERS RECOMMENDATIONS, CONFIRM CONNECTION AND POWER REQUIREMENTS FOR ELEVATOR AND AUXILIARY SYSTEMS (LIGHTING, INTERCOM, TELEPHONE) PRIOR TO ROUGH -IN AND INSTALLATION. 6. PROVIDE ON EMERGENCY POWER 204 60A / 3P 2 #12 #12 3/4' NOTE 3 & 7 EQ -6 GARBAGE DISPOSAL (2 #12,1 #12G)3 /4C - -- - - -- 1/2 120 1 / SPA EQUIP, 1788 2 #12 #12 3/4' NOTE 4 & 9 EQ -7 GAS FIREPLACE IGNITOR OVERLOAD - -- 1 #12G, - -- 120 1 AQUAMATIC HYDRALIC 3,0 POOL COVER 2 #12 #12 3/4' NOTE I & 7 EQUIP, 1/2 120 1 6,0 - - -- 20A / IP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 5 SP -18 COMPOOL CP #3810 - POOL CONTROL SYSTEM 120 RM 242 - POOL / SPA EQUIP, - - -- NOTES 1 310 - - -- 20A / 1P THERMAL OVERLOAD 2 #12, 1. COORDINATE CORD AND PLUG REQUIREMENTS WITH MANUFACTURER, PROVIDE LOCKABLE BREAKER. 2. MECHANICAL CONTRACTOR TO PROVIDE INTERLOCK AND CONTROL WIRING FOR UNIT. 3, COORDINATE CORD AND PLUG REQUIREMENTS WITH MANUFACTURER, 4, PROVIDE 20A /IP SWITCH ABOVE COUNTER. COORDINATE EXACT LOCATION OF SWITCH WITH ARCHITECT AND MILLWORK CONTRACTOR PRIOR TO ROUGH -IN. 5. COORDINATE SWITCHING REQUIREMENTS WITH MANUFACTURER, COORDINATE SWITCH LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN, 6. FIREPLACE IGNITOR TO BE INTERLOCKED TO GAS SUPPLY WITH INTEGRATED TIMER FOR SHUT -OFF OF GAS SUPPLY FOR PRE - DETERMINED TIME PERIOD. COORDINATE TIMER AND GAS SHUT -OFF WITH ARCHITECT PRIOR TO ROUGH -IN AND INSTALLATION OF FIREPLACE AND ASSOCIATED EQUIPMENT, 7, EQUIPMENT TO BE PROVIDED IN RESIDENTIAL UNITS, S. EQUIPMENT TO BE PROVIDED IN EMPLOYEE HOUSING UNITS. 9. EQUIPMENT TO BE PROVIDED IN BOTH EMPLOYEE HOUSING AND RESIDENTIAL UNITS, 3/4`C 20A / IP THERMAL OVERLOAD SP -19 SWIMMING POOL_ / SPA VAIL PLAZA HOTEL -- ELEVATORS EQ ID NUMBER EQUIPMENT DESCRIPTION HP VA VOLTAGE PH FLA MCA FEEDERS FUSE DISC ELEVATOR ELEVATOR TYPE SERVICE LOCATION MOTOR HP(WATTS) VOLTAGE PHASE FLA FUSE DISC, FEEDER COND. NOTES REMARKS 1 -A PASSENGER FLOOR 138 (GARAGE) - FLOOR 220 ROOF 30 480 3 40.0 50A FRS -R 50A / 3P 3 #6,1 #10G 1' 1,2,3,4,5,6 VOLT 1 -B PASSENGER FLOOR 138 (GARAGE) - FLOOR 220 ROOF 30 480 3 40.0 50A FRS -R 50A / 3P 3 #6,1 #10G V 1,2,3,4,5,6 EQUIP, 1 -C SERVICE FLOOR 138 (GARAGE) - FLOOR 220 ROOF 30 480 3 40.0 50A FRS -R 50A / 3P 3 #6 #I0G i' 1,2,3,4,5,6 SP -10 -B 2 SERVICE FLOOR 138 (GARAGE) - FLOOR 170 BSMNT 20 480 3 27.0 35A FRS -R 35A / 3P 3 #8,1 #10G 3/4' 1,2,3,4,5,6 20A FRN -R 208 30A / 2P 1 6,6 2 #12, 1 #12G, 3/4'C 9A FRN -R SP -12 CARLSON #10.0 HE POOL HEATER 60 QT. MIXER RM 242 - POOL / SPA EQUIP, (10) 208 3 27.8 35A NOTESi 1. PROVIDE ALL CIRCUITING, DISCONNECTS, THERMAL OVERLOAD SWITCHES, ETC, FOR ALL MECHANICAL EQUIPMENT, CIRCUIT ALL LINE VOLTAGE THERMOSTATS AND MOTOR OPERATORS. CIRCUIT ALL CONTROLLERS AND MOTORS. SEE ELEVATOR SHOP DRAWINGS FOR EQUIPMENT LOCATIONS, 2, CONDUCTOR SIZES INDICATED ARE COPPER THWN, 3. PROVIDE SHUNT -TRIP FUSED DISCONNECT IN NEMA 3 ENCLOSURE IN ELEVATOR MACHINE ROOM FOR EACH ELEVATOR, PROVIDE SHUNT -TRIP 120V CONTROL CIRCUIT. 4. CONDUCTOR SIZES INDICATED ARE MINIMUM. SIZE CONDUCTORS FOR A MAXIMUM OF 3 PERCENT VOLTAGE DROP. 5. PROVIDE FUSING PER ELEV. MANUFACTURERS RECOMMENDATIONS, CONFIRM CONNECTION AND POWER REQUIREMENTS FOR ELEVATOR AND AUXILIARY SYSTEMS (LIGHTING, INTERCOM, TELEPHONE) PRIOR TO ROUGH -IN AND INSTALLATION. 6. PROVIDE ON EMERGENCY POWER SWIMMING POOL_ / SPA EQUIPMENT SCHEDULE EQ ID NUMBER EQUIPMENT DESCRIPTION HP VA VOLTAGE PH FLA MCA FEEDERS FUSE DISC CONNECTION NOTES 1 WALK -IN COOLER - CODE MANUFACTURER/ MODEL NO; 1 SERVICE - 2 #12, 1#129, 3/4' C 20A / IP THERMAL OVERLOAD LOCATION H.W. 1 2 WALK -IN FREEZER - 500 120 ELECTRICAL - - 2 #12, 1#12g, 3/4' C 20A / IP THERMAL OVERLOAD REMARKS HP <KW) VOLT PH FLA FUSE DISCON, FEEDER SP -10 -A PENTAIR #WFE -8 POOL CIRC. PUMP 20A / IP THERMAL OVERLOAD RM 242 - POOL / SPA EQUIP, 2 208 1 132 20A FRN -R - 30A / 2P 20A / 1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 5 SP -10 -B PENTAIR #WFE -8 1800 POOL CIRC, PUMP 1 RM 242 - POOL / SPA EQUIP. 2 208 1 13.2 20A FRN -R 208 30A / 2P 1 6,6 2 #12, 1 #12G, 3/4'C 9A FRN -R SP -12 CARLSON #10.0 HE POOL HEATER 60 QT. MIXER RM 242 - POOL / SPA EQUIP, (10) 208 3 27.8 35A FRN -R 60A / 3P REACH -IN REFRIGERATOR 3 #8, 1 #I0G, 3/4`C 1 SP -14 CLEARWATER TECH, #M -15 -AD (2 #12,1 #12G)3 /4C POOL OZONE SYSTEM - - -- RM 242 - POOL / SPA EQUIP, 1788 120 1 3,0 - - -- 20A / IP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C - SP -15 AQUAMATIC HYDRALIC 1 POOL COVER - RM 242 - POOL / SPA EQUIP, 1/2 120 1 6,0 - - -- 20A / IP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 5 SP -18 COMPOOL CP #3810 - POOL CONTROL SYSTEM 120 RM 242 - POOL / SPA EQUIP, - - -- 120 1 310 - - -- 20A / 1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4`C 20A / IP THERMAL OVERLOAD SP -19 PENTAIR SAM LIGHT - 150W 6 POOL - LIGHTS - QTY (2) DOUBLE CONVECTION OVEN RM 242 - POOL / SPA EQUIP. - 120 1 2.5 1 - - -- 20A / IP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 28.8 - (3 #8,l0G)3/4'C 40A FRN -R 6OA /3P H.W, 16 -A 40 GALLON KETTLE - 600 120 1 5,O - <2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - ---- H.W. 16 -B 40 GALLON KETTLE - 600 SI -10 -A PENTAIR #WFDS -8 5,0 SPA 1 - JET PUMP (2 #12,1 #12G)3 /4 C RM 242 - POOL / SPA EQUIP. 2 208 1 13,2 20A FRN -R 4.0 30A / 2P (2 #12,1 #12G)3 /4 "C 2 #12, 1 #12G, 3/4'C S1 -10 -B PENTAIR #WFDS -8 SPA 1 - JET PUMP 120 RM 242 - POOL / SPA EQUIP, 2 208 1 132 20A FRN -R 945 30A / 2P 3 2 #12, 1 #12G, 3/4'C 4A FRN -R S1 -13 PENTAIR #WFE -8 SPA I - CIRC. PUMP IPREP TABLE RM 242 - POOL / SPA EQUIP. 1/2 208 1 7,7 10A FRN -R 21 -B 30A / 2P 2 #12, 1 #12G, 3/4'C 15,0 51 -11 CARLSON #5.0 HE 20A / 1P THERMAL OVERLOAD SPA 1 - HEATER 5 -20R RM 242 - POOL / SPA EQUIP. (5) 208 3 13,9 20A FRN -R 20A / IP THERMAL OVERLOAD 30A / 3P H.W. 3 #12, 1 #12G, 3/4'C - S1 -15 CLEARWATER TECH, #CD10 -AD 1 SPA 1 - OZONE SYSTEM - RM 242 - POOL / SPA EQUIP, 27 120 1 3.0 - - -- 20A / 1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C SI -18 COMPOOL CP #3810 1/4 SPA I - CONTROL SYSTEM 120 RM 242 - POOL / SPA EQUIP, - - -- 120 1 110 - - -- 20A / 1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 9A FRN -R 51 -19 PENTAIR SAM LIGHT - 150W SPA 1 - LIGHTS - QTY (1) EVAP. COIL - FREEZER RM 242 - POOL / SPA EQUIP. - 120 1 310 - - -- 20A / 1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 5,8 S1 -20 PENTAIR #WFE -4 20A / 1P THERMAL OVERLOAD SPA 1 - WATER FALL PUMP 5 -20R RM 242 - POOL / SPA EQUIP, 1 208 1 8.8 15A FRN -R - - -- 30A / 2P 2 #12, 1 #12G, 3/4 *C 6310 208 1 303 - (3 #8,1 #10G)3 /4'C 40A FRN -R 6OA /2P H,W. 40 PREP TABLE W/ SINK 1800 120 1 15.0 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5-20R 3 41 -A S2 -10 -A PENTAIR #WFDS -8 2150 SPA 2 - JET PUMP 1 RM 242 - POOL / SPA EQUIP. 2 208 1 132 20A FRN -R 120 30A / 2P 17.9 2 #12, 1 #12G, 3/4'C - - -- S2 -10 -B PENTAIR #WFDS -8 41 -C SPA 2 - JET PUMP - RM 242 - POOL / SPA EQUIP, 2 208 1 132 20A FRN -R PORTABLE HEATED CABINET 30A / 2P 2150 2 #12, 1 #12G, 3/4 "C 1 17:9 S2 -13 PENTAIR #WFE -8 20A / 1P THERMAL OVERLOAD SPA 2 - CIRC. PUMP 5 -20R RM 242 - POOL / SPA EQUIP, 1/2 208 1 7,7 10A FRN -R - - -- 30A / 2P 2 #12, 1 #12G, 3/4''C 3180 52 -11 CARLSON #5,0 HE 8.6 SPA 2 - HEATER <2 #12,1 #12G)3 /4'C RM 242 - POOL / SPA EQUIP, (5) 208 3 13.9 20A FRN -R 8.8 30A / 3P (2 #12,1 #12 /4'C 3 #12, 1 #12G, 3/4'C S2 -15 CLEARWATER TECH. #CD10 -AD 2 <2HP SPA 2 - OZONE SYSTEM 480 RM 242 - POOL / SPA EQUIP, 50A FRS -R 120 1 3.0 - - -- 20A / 1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C <3 #2,1 #8G)l -1 /4'C S2 -18 COMPOOL CP #3810 H,W. SPA 2 - CONTROL SYSTEM 56 -A RM 242 - POOL / SPA EQUIP. 24.0 120 1 110 - - -- 20A / 1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 S2 -19 PENTAIR SAM LIGHT - 150W 3 #10, 1 #10G, 3/4' C SPA 2 - LIGHTS - QTY <1) 30A /2P RM 242 - POOL / SPA EQUIP. 5000 120 1 3.0 1 - - -- 20A / 1P THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C S2 -20 PENTAIR #WFE -4 1 SPA 2 - WATER FALL PUMP - RM 242 - POOL / SPA EQUIP. 1 208 1 8,8 115A FRN -R 1 30A / 2P - 2 #12, 1 #12G, 3/4'C 5 -20R 64 HEATED CABINET - 2000 208/120 1 10.14 - (3 #12,1 #12G)3 /4'C 10A FRS -R 30A /lP L14 -20R 67 COLD WELL 1/3 940 120 1 73 - (2 #12,1 #12G)3 /4'C S3 -10 -A PENTAIR #WFDS -8 5 - 20R SPA 3 - JET PUMP 68 RM 242 - POOL / SPA EQUIP. 2 208 1 13.2 20A FRN -R 30A / 2P ICE MACHINE 2 #12, 1 #12G, 3/4'C 3 S3 -10 -B PENTAIR #WFDS -8 (3 #10,1 #IOG)3 /4'C SPA 3 - JET PUMP 3OA /2P RM 242 - POOL / SPA EQUIP. 2 208 1 132 20A FRN -R 20A / 1.P THERMAL OVERLOAD 30A / 2P 5 -20R 2 #12, 1 #12G, 3/4'C - S3 -13 PENTAIR #WFE -8 1 SPA 3 - CIRC, PUMP - RM 242 - POOL / SPA EQUIP, 1/2 208 1 7,7 10A FRN -R 24,0 30A / 2P 3 #10, 1 #10G, 3/4' C 2 #12, 1 #12G, 3/4'C S3 -11 CARLSON #5,0 HE - SPA 3 - HEATER 120 RM 242 - POOL / SPA EQUIP. (5) 208 3 13.9 20A FRN -R 500 30A / 3P 1 3 #12, 1 #12G, 3/4'C 10A FRS -R S3 -15 CLEARWATER TECH. #CD10 -AD SPA 3 - OZONE SYSTEM EVAP. COIL- COOLER RM 242 - POOL / SPA EQUIP. 6,6 120 1 10 - - -- 20A / IP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 1 1 S3 -18 COMPOOL CP #3810 (2 #12,1 #12G)3 /4'C SPA 3 - CONTROL SYSTEM - - -- RM 242 - POOL / SPA EQUIP, 120 1 110 - - -- 20A / IP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4 "C PIZZA PREP TABLE S3 -19 PENTAIR SAM LIGHT - 150W 120 SPA 3 - LIGHTS - QTY (I) 12;0 RM 242 - POOL / SPA EQUIP, 120 1 310 - - -- 20A / IP THERMAL OVERLOAD 2 #12, 1 #12G, 3/4'C 5 -20R 53-20 r PENTAIR #WFE -4 ROLL -IN REFRIGERATOR SPA 3 - WATER FALL PUMP 1370 RM 242 - POOL / SPA EQUIP, 1 208 1 1 8,8 15A FRN -R 30A / 2P 2 #12, 1 #12G, 3/4'C 118 BAIN MARIE HEATER 6310 208 1 303 1 (3 #8 #10G )1'C 40A FRS -R 60A /2P H.W, PART OF #117 119 CHAR BROILER NOTE! EQUIPMENT LISTED IS BASED ON EQUIPMENT LISTING AS PROVIDED IN SPA /POOL CONFIRM EQUIPMENT AND ELECTRICAL /MECHANICAL REQUIREMENTS WITH POOL /SPA DRAWINGS, CONTRACTOR /SUPPLIER PRIOR TO ROUGH -IN AND INSTALLATION. PART OF #117 120 SPREADER KITCHEN EQUIPMENT COORDINATION EQ ID NUMBER EQUIPMENT DESCRIPTION HP VA VOLTAGE PH FLA MCA FEEDERS FUSE DISC CONNECTION NOTES 1 WALK -IN COOLER - 500 120 1 - - 2 #12, 1#129, 3/4' C 20A / IP THERMAL OVERLOAD - - -- H.W. 1 2 WALK -IN FREEZER - 500 120 1 - - 2 #12, 1#12g, 3/4' C 20A / IP THERMAL OVERLOAD - - -- H,W. 2 3 PREP TABLE 1800 120 1 15,0 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 3 4 SLICER 1/2 1180 120 1 9.8 - (2 #12,1 #12G )3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 4 5 PREP TABLE W/ SINK 1800 120 1 154 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -_ 5 -20R 3 6 PREP TABLE DISPOSER 2 2385 208 3 1 6,6 - (3 #12,1 #12G)3 /4'C 9A FRN -R 30A /3P H,W, 8 60 QT. MIXER 2 2094 208 3 5,8 - (3 #12,1 #12G)3 /4C 8A FRN -R 3OA /3P H,W. 9 REACH -IN REFRIGERATOR - 1250 120 1 10,4 - (2 #12,1 #12G)3 /4C 20A / IP THERMAL OVERLOAD - - -- 5-20R 10 REACH -IN FREEZER - 1788 120 1 14.9 - (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 11 EXHAUST HOOD - 500 120 1 - - ( 2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- H.W. 5 12 EXHAUST HOOD - 500 120 1 - (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- H.W. 5 13 FIRE SUPRESSION SYSTEM - 500 120 1 1 - - (2 #12,1 #12G >3 /4 20A / IP THERMAL OVERLOAD - - -- H.W, 14 -A DOUBLE CONVECTION OVEN - (2) 1080 120 1 1 18.0 - <2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD -- - (2) 5 -20R 6 14 -B DOUBLE CONVECTION OVEN - (2) 1080 120 1 18.0 - <2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- (2) 5 -20R 6 15 .COOK & HOOD OVEN - 6000 208 1 28.8 - (3 #8,l0G)3/4'C 40A FRN -R 6OA /3P H.W, 16 -A 40 GALLON KETTLE - 600 120 1 5,O - <2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - ---- H.W. 16 -B 40 GALLON KETTLE - 600 120 1 5,0 - (2 #12,1 #12G)3 /4 C 20A / IP THERMAL OVERLOAD - - -- H,W. 17 2 COMPARTMENT STEAMER - 480 120 1 4.0 1 - (2 #12,1 #12G)3 /4 "C 20A / 1P THERMAL OVERLOAD - - -- H,W, 19 PREP TABLE 1800 120 1 15,0 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 3 20 IFOOD PROCESSOR 1 945 208 3 2.6 - <3 #12,1 #12G)3 /4'C 4A FRN -R 30A /3P H.W. 21 -A IPREP TABLE 1800 120 1 1510 <2 #12,1 #I203 /4'C 20A / lP THERMAL OVERLOAD - - -- 5 -20R 3 21 -B PREP TABLE 1800 120 1 15,0 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 3 25 EXHAUST HOOD - 500 120 1 - - (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- H.W. 5 26 FIRE SUPRESSION - 500 120 1 - - <2 #12,1 #12G>3 /4'C 20A / 1P THERMAL OVERLOAD - - -- H.W, 27 FRYER BATTERY 1/3 865 120 1 7.2 - (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 28 GRIDDLE 1/4 700 120 1 5,8 - (2 #12,1#12G)3/4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 29 EVAP, COIL - COOLER - 795 120 1 6,6 - (2 #12,1 #12G)3 /4'C 9A FRN -R 30A /IP H,W. 30 EVAP. COIL - FREEZER - 795 120 1 6.6 - (2 #12,1 #12G)3 /4'C 9A FRN -R 30A /1P H,W, 32 RANGE 1/4 700 120 1 5,8 - (2 #12,1 #l2G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 33 RANGE 1/4 700 120 i 1 5.8 - (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 39 BAIN MARIE HEATER - 6310 208 1 303 - (3 #8,1 #10G)3 /4'C 40A FRN -R 6OA /2P H,W. 40 PREP TABLE W/ SINK 1800 120 1 15.0 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5-20R 3 41 -A PORTABLE HEATED CABINET - 2150 120 1 17,9 - <2 #10,1 #I0G)3 /4'C 20A / 1P THERMAL OVERLOAD --- -- 5 -20R 41 -B PORTABLE HEATED CABINET - 2150 120 1 17.9 - <2 #10,1 #I0G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 41 -C PORTABLE HEATED CABINET - 2150 120 1 17.9 - (2 #10,1 #10G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 41 -D PORTABLE HEATED CABINET - 2150 120 1 1 17:9 - (2 #10,1 #10G)3 /4 "C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 41 -E PORTABLE HEATED CABINET - 2150 120 1 17,9 - (2 #10,1 #105)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 44 DISPOSER W/ PRE -RINSE 3 3180 208 3 8.6 - <2 #12,1 #12G)3 /4'C 11A FRN -R 3OA /1F H.W. 47 DISPOSER W/ PRE -RINSE 3 3180 208 3 8.8 - (2 #12,1 #12 /4'C 11A FRN -R 30A /1P H,W. 48 WARE WASHER 2 <2HP 31605 480 3 38.0 - (3 #4,1 #IOG)1 -1 /4'C 50A FRS -R 6OA /3P H.W. 50 BOOSTER HEATER - 54045 480 3 65.0 - <3 #2,1 #8G)l -1 /4'C 85A FRS -R 100A /3P H,W. 56 -A COFFEE BREWER - 5000 208 1 24.0 - 3 #10, 1 #I0G, 3/4' C 30A FRN -R 3OA /2P L14 -30R 56 -B COFFEE BREWER 5000 208 1 24.0 - 3 #10, 1 #10G, 3/4' C 30A FRN -R 30A /2P L14 -30R 56 -C COFFEE BREWER 5000 208 1 24.0 - 3 #10, 1 #10G, 3/4' C 30A FRN -R 30A /2P L14 -30R 56--D COFFEE BREWER 5000 208 1 24.0 - 3 #10, 1 #10G, 3/4' C 30A FRN -R 3OA /2P L14 -30R 61 REACH - IN REFRIGERATOR - 1250 120 1 10,4 - ( 2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 64 HEATED CABINET - 2000 208/120 1 10.14 - (3 #12,1 #12G)3 /4'C 10A FRS -R 30A /lP L14 -20R 67 COLD WELL 1/3 940 120 1 73 - (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 - 20R 68 HOT FOOD WELLS - 2550 208 1 123 - <3 #12,1 #12G)3 /4C 30A FRS -R 30A /2P L6 -20R 69 ICE MACHINE 3,5 6435 208 3 - 173 (3 #10,1 #IOG)3 /4'C 30A FRS -R 3OA /2P H,W, HACR 71 COUNTER TOP REFRIGERATOR 1/5 540 120 1 1 4,5 - (2 #12,1 #12G >3 /4'C 20A / 1.P THERMAL OVERLOAD - - -- 5 -20R 72 TEA DISPENSER - 5000 1 208 1 24,0 - 3 #10, 1 #I0G, 3/4' C - - L14-30R 73 COFFEE BREWER - 5000 208 1 24,0 - 3 #10, 1 #10G, 3/4' C - - L14--30R 74 JUICE DISPENSER - 1200 120 1 10.0 - (3 #10,1 #IOG)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 100 BEVERAGE COOLER 500 120 1 (2 #12,1 #12G)3 /4'C 10A FRS -R 30A /1P H.W. 102 EVAP. COIL- COOLER 795 120 1 6,6 1 (2 #12,1 #12G)3 /4'C 10A FRS -R 3OA /1P H.W, 107 REACH -IN REFRIG, /FREEZER 1920 120 1 1 16.0 1 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 110 PIZZA OVEN 150 120 1 1,1 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- H.W. 111 PIZZA PREP TABLE 1440 120 1 12;0 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD ---- 5 -20R 113 DOUGH ROLLER 1650 120 1 13.8 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 114 ROLL -IN REFRIGERATOR 1370 120 1 11,4 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD ---- -- 5 -20R 117 WALDORF SUITE 118 BAIN MARIE HEATER 6310 208 1 303 1 (3 #8 #10G )1'C 40A FRS -R 60A /2P H.W, PART OF #117 119 CHAR BROILER H,W. PART OF #117 120 SPREADER H.W. PART OF #117 121 PASTA COOKER H.W. PART OF #117 122 PASTA RINSE H,W. PART OF #117 123 RANGE W/ GRIDDLE H,W. PART OF #117 124 COLD PAN 20A / IP THERMAL OVERLOAD - - -- HW. PART OF #117 125 EXHAUST HOOD 500 120 1 t2 #12,1 #12G)3 /4`C H.W. 126 EXHAUST HOOD 500 120 1 (2 #12,1 #1216)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- H.W. 127 -A 10 QT. KETTLE PART OF #117 127 -B 10 QT. KETTLE PART OF #117 128 FRENCH HOT TOP RANGE PART OF #117 129 GRIDDLE PART OF #117 130 OPEN BURNER RANGE 20A / 1P THERMAL OVERLOAD - - -- PART OF #117 131 EXHAUST HOOD 500 120 1 <2 #12,1 #12G)3 /4'C H.W. 132 FIRE SUPRESSION SYSTEM 500 120 1 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- H,W. 134 DOUBLE CONVECTION OVEN <2) 1080 120 1 9,0 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- (2) 5 -20R 136 WORK COUNTER W/ REFRIG, BA E 1440 120 1 <2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - --- H.W. 137 WALK -IN COOLER 500 120 1 <2 #12,1 #12G)3 /4C 20A / 1P THERMAL OVERLOAD - - -- H.W. 140 EVAP. COIL - COOLER 795 120 1 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- H.W. 142 WALK -IN FREEZER 500 120 1 <2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- H.W. 143 EVAP, COIL - FREEZER 1 795 120 1 (2 #12,1 #12G)3 /4 *C 20A / 1P THERMAL OVERLOAD - - -- H.W, 146 COLD WELL 1/3 940 120 1 7.8 - (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 147 1HOT FOOD WELLS - 2550 208 1 12.3 - (2 #12,1 #12G)3 /4'C 15A FRS -R 3OA /2P L6 -20R 150 -A COFFEE BREWER 5000 208 1 24,0 1 (2 #10,1 #1016)3 /4 30A FRS -R 3OA /2P L14 -30R 150 -B COFFEE BREWER 5000 208 1 24.0 <2 #10,1 #10G)3 /4'C 30A FRS -R 30A /2P L14 -30R 151 HEAT LAMP W/ LIGHT 1250 120 1 <2 #12,1 #12G >3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 152 SODA SYSTEM 1440 120 1 (2 #12,1 #12G >3 /4'C 20A / IP THERMAL OVERLOAD - - -_ H.W, 153 REMOTE BEER SYSTEM 1300 120 1 1018 (2 #12,1 #12G)3 /4C 20A / 1P THERMAL OVERLOAD - - -- H.W, 154 ESPRESSO MACHINE 3330 208 1 16.0 <2 #12,1 #12G)3 /4'C 30A FRS -R 30A /2P H.W, 156 BACK BAR REFRIGERATOR 1060 120 1 818 1 <2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 158 -A BLENDER 1800 120 1 (2#12,1 #12G >3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 158 -B BLENDER 1800 120 1 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 164 GLASS WASHER 5000 120/208 1 (3 #10,1 #1016)3 /4'C 30A FRS -R 3OA /2P H.W, 166 -A ICE TEA DISPENSER 5000 208 1 24.0 (2#10,1 #10G)3 /4'C 30A FRS -R 30A /2P L14 -30R 166 -B ICE TEA DISPENSER 5000 208 1 24.0 <2 #10,1 #l0G >3 /4'C 30A FRS -R 3OA /2P L14 -30R 167 -A SODA / ICE DISPENSER 1200 120 1 1010 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - --- 5 -20R 167 -B SODA / ICE DISPENSER 1200 120 1 10.0 <2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 169 GRINDER 600 120 1 5,0 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- H.W. 171 REACH -IN REFRIGERATOR 1250 120 1 104 (2 #12,1#12G)3/4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 172 MICROWAVE OVEN 2700 208 1 (2 #12,1 #12G)3 /4'C 30A FRS -R 30A /2P 6 -20R 173 HEATED DRAWER 600 120 1 1 5;0 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 174 TOASTER 2200 120 1 183 (2 #10,1 #10G)3 /4'C 20A / 1P THERMAL OVERLOAD - - --- 5 -300 176 JUICE DISPENSER 1200 120 1 1010 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 177 TEA DISPENSER 5000 208 1 24,0 (2 #10,1 #IOG)3 /4'C 30A FRS -R 30A/2P L14 -30R 178 COFFEE BREWER 5000 208 1 24.0 (2 #10,1 #I0G)3 /4'C 30A FRS -R 3OA /2P L14 -30R 179 -A SODA / ICE DISPENSER 1200 120 1 10.0 (2 #12,1 #126)3 /4C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 179 -B SODA / ICE DISPENSER 1200 120 1 10,0 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 187 ICE MACHINE 3640 208 1 17,5 <2 #10,1 #1003 /4'C 25A FRS -R 3OA /2P HW HACR 191 -A ICE MACHINE 6420 208 3 17.8 (2 #10,1 #106)3 /4C 25A FRS -R 30A /3P HW HACR 191 -B ICE MACHINE 6420 208 3 17.8 (2 #10,1 #10G)3 /4'C 25A FRS -R 3OA /3P HW HACR 196 BOOSTER HEATER - 54000,0 480 3 65,0 - (3 #2,1 #8G)l -1 /4'C 85A FRS -R 10OA /3P HW 198 DISHWASHING MACHINE 2 (2HP ) 25000 480 3 38.0 - (3 #6,1 #IOG)I'C 50A FRS -R 60A/3P HW 199 DISPOSER W/ PRE -RINSE 3 3180 208 3 8,8 - <2 #12,1 #12G)3 /4'C 15A FRN -R 30A /3P HW 210 ICE CREAM CABINET 1800 120 1 15.0 <2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- HW HACR 216 REFRIGERATED BASE 1440 120 1 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- HW 220 PASS -THRU REFRIGERATOR 996 120 1 83 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 222 COLD WELL 1/3 936 120 1 7.8 - (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 224 TOASTER 2200 120 1 1813 (2 #10,1 #10G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -30R 225 MICROWAVE OVEN 2870 208 1 13.8 (2 #10,1 #106)3 /4'C 20A FRS -R 3OA /2P 6 -20R 226 HEAT LAMP W/ LIGHT 1100 120 1 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 227 HOT FOOD WELLS - 2550 208 1 16,3 - (3 #10,1 #IOG >3 /4'C 20A FRS -R 3OA /2P L6 -30R 228 -A SOUP WELL 830 120 1 65 (2 #12,1 #12G)3 /4C 20A / 1P THERMAL OVERLOAD - - -- HW 228 -B SOUP WELL 830 120 1 6,9 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- HW 229 BAIN MARIE HEATER - 4800 208 1 23,0 - <3 #10,1 #1003 /4'C 30A FRS -R 30A /2P 6 -30R 231 PRINTER 500 120 1 (2 #12,1 #12G)3 /4'C 20A / 1P,- THERMAL OVERLOAD - - -- 5 -20R 232 SALAD TOP REFRIGERATOR 1440 120 1 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- HW 236 REACH -IN REFRIGERATOR - 1380 120 1 11,5 - (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 237 FRYER BATTERY 600 120 1 1 510 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 243 DOUBLE CONVECTION OVEN (2) 1080. 120 1 910 <2 #12,1 #12G)3 /4'C 2OA / IP THERMAL OVERLOAD - - -- (2) 5 -20R 244 EXHAUST HOOD 500 120 1 (2 #12,1 #12G )3 /4'C 20A / IP THERMAL OVERLOAD - ---- H.W, 245 FIRE SUPRESSION - 500 120 1 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- H,W, 249 REMOTE REFRIGERATION SYSTEM 20040 208 3 55,5 (3 #4, 1 #8G)1 -1 /4'C 60A FRS -R 60A /3P M.W. 250 WALK -IN COOLER 500 120 1 (2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- H,W, 251 EVAP. COIL - COOLER - 795 120 1 6.6 - (2 #12,1 #12G)3 /4C 20A / IP THERMAL OVERLOAD - - -- H,W, 253 WALK -IN FREEZER 500 120 1 (2 #12,1 #12G)3 /4C 20A / IP THERMAL OVERLOAD - - -- H,W, 255 EVAP, COIL- FREEZER - 795 120 1 6.6 - (2 #12,1 #12G)3 /4C 20A / 1P THERMAL OVERLOAD - - -- H.W, 260 ESPRESSO MACHINE 3330 208 1 1610 (2 #12,1 #12G)3 /4'C 30A FRS -R 3OA /2P H.W. 261 BACK BAR REFRIGERATOR 1060 120 1 8.8 <2 #12,1 #12G >3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 264 BOTTLE COOLER 735 120 1 611 <2 #12,1 #12G)3 /4'C 20A / IP THERMAL OVERLOAD - - -- 5 -20R 266 BLENDER 1800 120 1 (2 #12,1 #12G)3 /4'C 20A / 1P THERMAL OVERLOAD - - -- 5 -20R 268 COFFEE BREWER 5000 208 1 24,0 <2 #10,1 #1003 /4'C 30A FRS -R 3OA /2P L14 -30R 272 TEA DISPENSER 5000 208 1 24.0 (2 #10,1 #IOG)3 /4'C 30A FRS -R 30A /2P L14 -30R NOTESi 1, REFER TO ITEM 29 (EVAP. COIL - COOLER) FOR CONDENSER UNIT FOR COOLER, PROVIDE ONE (1) - 20A /IP GFCI RECPTACLE ADJACENT TO CONDENSER UNIT. 2. REFER TO ITEM 30 (EVAP. COIL - FREEZER) FOR CONDENSER UNIT FOR FREEZER, PROVIDE ONE <1> - 20A /1P GFCI RECPTACLE ADJACENT TO CONDENSER UNIT, 3, CONVENIENCE RECEPTACLE TO BE PROVIDED, ONE (1) - 2OA /IP GFCI RECPTACLE. 4. UNIT TO BE PROVIDED WITH ONE (1) 6 FOOT, 3 WIRE CORD AND PLUG. VERIFY PLUG CONFIGURATION WITH KITCHEN EQUIPMENT CONSULTANT PRIOR TO ROUGH -IN. 5. UNIT TO BE PRE -WIRED FOR LIGHTING, COORDINATE FINAL CONNECTION WITH KITCHEN CONSULTANT PRIOR TO ROUGH -IN, 6. UNIT TO BE PROVIDED WITH ONE (1) 6 FOOT, 3 WIRE CORD AND PLUG PER SECTION, UNITS TO DRAW 9.0 AMPS PER SECTION, 18 AMPS TOTAL DRAW. VERIFY PLUG CONFIGURATION WITH KITCHEN EQUIPMENT CONSULTANT PRIOR TO ROUGH -IN, H-6 Oj WEERS f NC. 0048 f. wvm CHEEK MM OTC 307 A.o. ROX 040, AVON, CO. 91620 ` PH: M O ) 141-000 FAX (170) 141 -11SI