HomeMy WebLinkAboutM11-0020 FIREPLACESNOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT
MWWO Vv
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
MECHANICAL PERMIT
ADUP
Job Address: 925 FAIRWAY DR VAIL
Location.....: WEST UNIT
Parcel No...: 210108116015
OWNER ALLEN, LARRY M. & LORI L. 02/08/2011
450 SHERWOOD RD
SHREVEPORT
LA 71136
APPLICANT HOME & HEARTH OUTFITTERS
730 S. JASON ST. #28
DENVER
COLORADO 80223
License: 368 -M
CONTRACTOR HOME & HEARTH OUTFITTERS
730 S. JASON ST. #28
DENVER
COLORADO 80223
License: 368 -M
02/08/2011 Phone: (303) 327-4654
02/08/2011 Phone: (303) 327-4654
Desciption: INSTALL 7 FIREPLACES. 4 MASONRY AND 3 DIRECT VENT.
Valuation: $27,520.00
ALL TIMES
Permit M M11 -0020
Project #: PRJ10 -0049
Status ...:
ISSUED
Applied ..:
02/08/2011
Issued. ..
02/2512011
Expires . .:
08/24/2011
Mechanical Permit Fee --- > $560.00 Will Call ------------ > $5.00 Total Calculated Fees --- > $705.00
Plan Check ------------------- > $140.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00
Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $705.00
Item: 05100 BUILDING DEPARTMENT
02/23/2011 JRM Action: AP
Total Calculated Fees - -> $705.00 Payments ----- — ---------- > $705.00
BALANCE DUE --------- > $0.00
APPROVALS
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.47 .2149 O AT OUR OFFICE FROM 8:01
AM - 4 PM.
Signatur f Owner or C tractor Date
Print Name
mechca n ical_permit_041908
TOWN OF VAIL, COLORADO Statement
Statement Number: R110000133 Amount: $705.00 02/25/201110:48 AM
Payment Method:Credit Crd Init: SAB
Notation: VISA -BRIAN
STRICKLAND /HOME AND HEARTH
-----------------------------------------------------------------------------
Permit No: Mll -0020 Type: MECHANICAL PERMIT
Parcel No: 2101 - 081 - 1601 -5
Site Address: 925 FAIRWAY DR VAIL
Location: WEST UNIT
Total Fees: $705.00
This Payment: $705.00 Total ALL Pmts: $705.00
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
MP 00100003111100 MECHANICAL PERMIT FEES 560.00
PF 00100003112300 PLAN CHECK FEES 140.00
WC 00100003112800 WILL CALL INSPECTION FEE 5.00
e rec
Project Street Address:
2 S h,4 l/ZVA Y c2R-r v� WEST
(Number) (Street) (Suite #)
Building /Complex Name:
Contractor Information
.,... .... ....w,,, aw a n
1.nRm101I UEv t0 - 00!!
Project #: P � j o - oo
DRB #:
Building Permit#: Si t) OI /►') ! I — 0 'a 0
W
Lot #: Block # Subdivision:
Business Name: /-/a�` t r f NEB R37 / ovTF� n'rz�s Work Class: New (J�'Addition ( ) Alteration( )
Business Address: `399 C, F VA"—r 57 1- Type of Building:
F/
City Dvvfn State: C0 Zip: 6 2 / Single - Family ( ) Duplex �Aulti- Family ( )
Contact Name: �Y� r�r'/oicrt�✓D Commercial( ) Other( )
Contact Phone: 97v S �4 - - ^? /
Contact E -Mail: kydcn1ea��ftu�.- ��na��i�e�s
Contractor Registration Number: C 8 - Al
Owner / er's Representative Signature (Required)
Project Information
Owner Name 44 4e - Al
Parcel #:
(For Parcel #, contact Eagle County Assessors Office at (970,428 -8640 or visit
www.eagiscounty.usipatie)
Work Type: Interior ( ) Exterior ( ) Both( )
Valuation of
Work Included Plans Included Work
Electrical
( )Yes (
)No
( )Yes
(klNo
Mechanical
(,, es (
)
)No (
)Yes
(�1CIo S20
Plumbing
( )Yes (
)No (
)Yes
(y}No
Building
( )Yes (
)No (
)Yes
(/i)No
Value of all work being performed: y
(value based on BC section 109,3 & IRC Section 108.3)
Electrical Square Footage
Detailed Scope and Location of Work: /Nyr,QU (7) Filzr - ,A c-
(use additional sheet if necessary)
For Office Use Only:
Fee Paid:
Received From:
Cash Check #
CC: Visa / MC Last 4 CC # exp date:
Auth #
Date
FEB 7 2011
TOWN OF VAIL
p (-a, f � h-�-�- 142 e
BUILDING PERMIT APPLICATION
(Separate applications ar ; A F— -- o __
for
architects
designers
TOWN & COUNTRY
L U X U P Y F I P E P L A C E S'
TC36 & TC36 Arch
Series C
IMPORTANT
This booklet is intended as a basic
specification guide for architects,
designers and builders. Please refer
to the Instruction Manual
supplied with the fireplace for
detailed information regarding
installation and operation.
Product installation manuals can
also be viewed at:
www .townandcountryfireplaces.com
1 TC36.CE 050710 -11
47 3/16
25 3/4 11 11/16
I
11 I( /16
a ®
241/16 4713/16 Y
®
47 13/16
O
O
V
®
32 1/8
32 3/16
N k COUNTRY
RI�IAC Is
37 1/2
L 37
I
,
TOWN k CcRibrm
_
112
37 1 12
® TC36.CE Cad Drawing
Available at
A :_ www .townandcountryfireplaces.com
28
11 7/16
36 1/8
24 1/16-
2 TC36.CE TOWN & COUNTRY 050710 -11
L U X U R Y PI R E P L A C E S
COMBUSTIBLE FRAM
AND FINISH WALL AB
STANDOFFS
MAY USE COMBUSTIE
FACING MATERIAL IN
AREA
NON - COMBUSTIBLE
FINISH MATERIAL
TC
FIREPLA
DFFS
NON - COMBUSTIBLE ZONE.
DO NOT INSTALL ANY
COMBUSTIBLE MATERIAL,
ELECTRICAL WIRING,
INSULATION, PLASTIC
VAPOUR BARRIER OR
GAS PLUMBING IN THIS
AREA
REF.
MANTLE CLEARANCE
REF.
MANTLE EXTENSION
A
9"
D
12"
B
6"
E
6 3/4"
C
3"
F
1 1/2"
Side standoffs ......................
0 in.
(0 mm)
Back standoffs .....................
0 in.
(0 mm)
Top standoffs .......................
0 in.
(0 mm)
Bottom of appliance .............
0 in.
(0 mm)
Adjacent sidewall .................
4 in.
(102 mm)
Ceiling to appliance ...........
24 in.
(610 mm)
Mantel to appliance .........................See
above
Maximum mantel extension ..........See
above
Mantel support .....................
4 in.
(102 mm)
Vertical vent pipe ...............1
3/4"
(45mm)
Horizontal vent pipe
(Top, sides and bottom) .....
1 3/4"
(45mm)
Za
UP TO
6" WITH NON - COMBUSTIBLE
MASONRY TYPE MATERIAL
3 TC36.CE TOWN & COUNTRY 050710 -11
L U X U R Y F1 R E P L A C E S
Non - combustible Zone
Do not install any
combustible material,
electric wiring,
insulation, plastic
vapour barrier or
gas plumbing 12"
within the steel
stud frame.
12 v4"
All other framing
can be done with
conventional lum
— — - 48" ..
Including Sheetrock
° 1211/16'
23 3/8" � �_ _ _ � 54
3/4• J
4E
NOTE: Fireplace should be in its
final location before framing.
Non - combustible board (or
other non - combustible
material) must extend 12"
above and 4 1/2" to the sides
of the framing edges.
4 TC36.CE TOWN & COUNTRY 050710 -11
L U X U R Y F1 R 9 D L A C E S
NON - COMBUSTIBLE
BOARD
48„
Town and Country C Series fireplaces include our award
winning Maestro controls.
They include an elegant, programmable remote control
with a count -down timer, weekday /weekend on /off timer,
manual control and thermostat mode (where permitted), Up to 50 Feet
and an easy to read LCD display.
They also come with a small, wall- mounted control which
permits on /off operation, flame modulation and houses
the battery back -up system for operation during power
outages.
Maestro controls use an on- demand electronic ignition
system, a green alternative to standing pilots, which can
cut your annual fuel consumption up to 74 %.
Caution: While a hearth extension is not required and WINDOW
combustible flooring materials may be brought directly up to FRAME
the fireplace, many materials (such as wood flooring) may
not tolerate the radiant heat from this fireplace, resulting in
discoloration, shrinking and cracking. For this reason, we
suggest a non - combustible hearth that is no more than 1" MAX
above the bottom of the fireplace. If thicker, fireplace must
be raised accordingly.
Caution: Hearth extensions thicker than 1 "will interfere with
the window frame when opening.
HEARTH
EXTENSION
0
D
O
0
0
1 1
1/4"
WINDOW
TRACK
PAS
D0e7
oda
Su
Caution: This fireplace may be recessed up to a maxi-
mum depth of 6 ". This recess must be constructed from
non combustible material. The space between the outside
framing edge and the firebox must be completely free of
any obstructions or debris and the window, with trim fit-
ted, must be able to move freely. No building material is
permitted to protrude past the framing edges attached to
the fireplace under ANY circumstance.
FRAMING
EDGES
GLASS
FRAME
NON - COMBUSTIBLE
FINISH MATERIAL
5 TC36.CE TOWN & COUNTRY 050710 -11
L U% U P V P1 P E P L 4 C E 5
14 112"
FRAMED
OPENING
WALL SHIELD THIMBLE
12" VENT PIPE
ELBOW
24" VENT
PIPE
HORIZONTAL
TERMINAL
68 112"
" Minimum height from the floor to center of the opening with a
maximum horizontal run of 18" from the center of the flue outlet
to the outside face of the outer wall. The height will need to be
increased if a longer horizontal pipe is required.
6 TC36.CE TOWN & COUNTRY 050710 -11
L U X U R Y F I R E P L A C E S
7 TC36.CE TOWN & COUNTRY 050710 -11
L U X U P Y PI P E P L A C E S
A
B
C
D
Minimum rise
Pipe length
Maximum run
Pipe length
I
I I
Maximum
681/2"
1 -24"
29"
1 -12"
72 3/4"
1 -12" 1 -18"
75 1/4"
1 -48" 1 -12"
78 3/4"
1 -24" 1 -12"
11'1 112"
2 -48" 1 -24"
84 3/4"
1 -24" 1 -18"
15,101,
3 -48" 1 -24"
1 -12"
92 1/2"
1 -48"
20' 10"
5 -48"
For other rise /run combinations see chart below
48'
MAX.
46'
44'
42'
10'
8'
6'
4 '
6'
4'
8'
24" Pipe NOTE: The vent must not exceed a total length of
length 68 feet. Any combination of rise and run may be
minimum used, but must be constrained to the boundaries of
this chart. A total of four 90° elbows or combination
of other elbows equalling 90° can be used without
reducing horizontal run. For each additional 90°
elbow, or an equal combination of elbows, reduce
Awl horizontal vent run by 2 feet. Ensure vent pipe is
n properly supported.
** All dimensions are approximate. Both rise and run may vary with different
combinations of pipe.
I
48" Min
TCVT Roof Vent Cad Drawing
Available at
www. town and count ryfi replaces. com
8 TC36.CE TOWN & COUNTRY 050710 -11
L U X U R Y PI R E D L A C E 5
I
I I
ff
I
I I
I
I I I I
I
I I
1
I '
I I I
–�
-- - - = —i - -- - - - - -L 1
I
48" Min
TCVT Roof Vent Cad Drawing
Available at
www. town and count ryfi replaces. com
8 TC36.CE TOWN & COUNTRY 050710 -11
L U X U R Y PI R E D L A C E 5
Minimum clearances to the vent terminal must be maintained as
shown (See illustration to right & below). Measure clearances to the
nearest edge of termination hood. (See pitch table below).
NOTE: Vent terminal must not be recessed
NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE
DIFFERENT CLEARANCES.
Roof Pitch Table
(minimum)
Clearances above grade, veranda porch, deck or balcon
ft
m
Flat to 6/12
1.00
0.30
Over 6/12 to 7/12
1.25
0.38
Over 7/12 to 8/12
1.50
0.46
Over 8/12 to 9/12
2.00
0.61
Over 9/12 to 10/12
2.50
0.76
Over 10/12 to 11/12
3.25
0.99
Over 11112 to 12/12
4.00
1.22
VENT TERMINAL AREA WHERE TERMINAL �
AIR SUPPLY INLET ® IS NOT PERMITTED ILG]l GAS METER
A=
*12 inches 30 cm min.
Clearances above grade, veranda porch, deck or balcon
B=
*12 inches 30 cm min.
Clearance to window or door that may be opened
C=
12 inches 30 cm min.
Clearance to permanently closed window recommended to prevent condensation on window
D=
30 inches (76 cm) min.
Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the
edge of the terminal
E=
30 inches 76 cm min.
Clearance to unventilated soffit
F=
6 inches (15 cm) min.
Clearance to outside corner
G=
6 inches 15 cm min.
Clearance to inside corner
H=
3 feet (90 cm) min.
'Not to be installed above a meter /regulator assembly within 3 feet (90 cm) horizontally from the center -line of the
regulator
1=
'6 feet (1.8 m) min.
Clearance to service regulator vent outlet
J= 1
*12 inches (30 cm) min.
Clearance to non - mechanical air supply inlet to building or the combustion air inlet to any other appliance
K=
*6 feet (1.8 m) min.
Clearance to a mechanical air supply inlet
L=
*7 feet (2.1 m) min.
^ Clearance above paved side -walk or a paved driveway located on public property
M=
* *30 inches (76 cm) min
Clearance under veranda, porch, deck, or balcony
^ a vent shall not terminate directly above a side -walk or paved driveway which is located between two single family dwellings and serves both dwellings`
" only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor'
as specified in CAN /CSA B149 Installation Codes, Note: local Codes or Regulation may require different clearances
for U.S.A. Installations follow the current National Fuel Gas Code. NFPA54 /ANSI Z223.1
9 TC36.CE
TOWN & COUNTRY
L U X U R Y P1 R E P L A C E S
VENTTERMINAL MINIMUM CLEARANCES
TO ADJACENT STRUCTURES
36•
s1 m za
(87 cm)
See Roof Pitch Table
ae•
fizz cm)
A0.IACENT
STRUCTURES
OR FENCE
050710 -11
Reach almost any room or commercial setting.
Optional Power Venting allows runs up to 110' from
an outside wall or roof surface. Vent horizontally or
vertically with up to six 90- degree elbows, including
runs up to T below the fireplace.
The premium Power Vent fan runs quietly outside,
at the exterior terminal.
Wall Termination
Standard Venting
Roof Termination
TL
Roof Termination
At 40
.. „.
Flush Mount
Horizontal Termination
I
Cad Drawings available at www .townandcountryfireplaces.com
Standard Venting
Wall Termination
Stainless Steel Standard Venting
Termination for Condo Installation
,4ML Cad Drawings available at www .townandcountryfireplaces.com
i
A
iu icsb.ct TOWN & COUNTRY 050710 -11
L U X U R V F1 R E P L A C E S
0
TOWN & COUNTRY
L U X U P Y F I P E P L A C E S._,
For personal service pertaining to specific projects, contact:
Town & Country Architect Resource Planner
architects @ pacifi cenergy. net
Web: www .townandcountryfireplaces.com
Phone: (250) 748 -1184
Toll Free: 1 -877- 715 -2664
2975 Allenby Road, Duncan, BC Canada V91L 6V8
Printed in Canada
IUWN ,�, COUNTRY
L U X U R Y PI R E P L A C E 5
for
architects
designers
TOWN & COUNTRY
L U X U R Y F1 R E P L A C E S"
TC42
Series C
M
IMPORTANT
This booklet is intended as a basic
specification guide for architects,
designers and builders. Please
refer to the Instruction Manual
supplied with the fireplace for
detailed information regarding
installation and operation.
Product installation manuals can
also be viewed at:
www.townandcountryfi replaces. com
1 TC42.CE 050710 -11
11 11/16
50 3/16
29 1/4-
53 7/B
® 38 1/8
O
0 O m 26 15/16 I TOWN lCOUNT$Y
® ® I gym•
43 9/16 1 1-43 9116
TC42.CE Cad Drawing
®_ Available at
www .townandcountryfireplaces.com
/16
z TC42.CE TOWN & COUNTRY 050710 -11
L U X U R Y PI R E P L A C E S
COMBUSTIBLE FRAM
AND FINISH WALL AB
STANDOFFS
MAY USE COMBUSTIE
FACING MATERIAL IN
AREA
NON - COMBUSTIBLE
FINISH MATERIAL
TC
FIREPLA
DFFS
NON - COMBUSTIBLE ZONE.
DO NOT INSTALL ANY
COMBUSTIBLE MATERIAL,
ELECTRICAL WIRING,
INSULATION, PLASTIC
VAPOUR BARRIER OR
GAS PLUMBING IN THIS
AREA
REF.
MANTLE CLEARANCE REF.
MANTLE EXTENSION
A
9" D
12"
B
6" E
6 3/4"
C
3" F
1 1/2"
Side standoffs ...................... 0 in.
(0 mm)
Back
in.
standoffs .....................
0
(0 mm)
G
Top standoffs .......................
0 in.
(0 mm)
Bottom of appliance .............
0 in.
(0 mm)
Adjacent sidewall .................
4 in.
(102 mm)
Ceiling to appliance ...........
24 in.
(610 mm)
24"
Mantel to appliance .........................See
above
Maximum mantel extension ..........See
above
Mantel support .........................
4"
(102 mm)
Vertical vent pipe ...............1
3/4"
(45mm)
Horizontal vent pipe
(Top, sides and bottom) .....
1 3/4"
(45mm)
38 1/8
Ap
J
Mql( � NT
Sapp E R
ri R1
4"
UNIT MAY BE RECESSED UP TO
6" WITH NON - COMBUSTIBLE
MASONRY TYPE MATERIAL
3 TC42.CE TOWN & COUNTRY 050710 -11
L U X U R Y F1 R E P L A C E 5
Non - combustible Zone.
Do not install any
combustible material,
electric wiring,
insulation, plastic
vapour barrier or
gas plumbing �z
within the steel
stud frame.
38'
All other framing
can be done with
conventional lumber
54"
Including Sheetrock
26 1/8"
N
I
hO
12 5/8"
Non - combustible board (or
other non - combustible
material) must extend 12"
above and 5" to the sides of
the framing edges.
NOTE: Fireplace should be in its
final location before framing.
4 TC42.CE TOWN & COUNTRY 050710 -11
L U X U R Y P1 R E D L A C E S
V� --- 54 "—— •I
NON - COMBUSTIBLE
BOARD
3/4'
Town and Country C Series fireplaces include our award
winning Maestro controls.
They include an elegant, programmable remote control
with a count -down timer, weekday /weekend on /off timer,
manual control and thermostat mode (where permitted),
and an easy to read LCD display.
They also come with a small wall- mounted control which
permits on /off operation, flame modulation and houses
the battery back -up system for operation during power
outages.
Maestro controls use an on- demand electronic ignition
system, a green alternative to standing pilots, which can
cut your annual fuel consumption up to 74 %.
Caution: While a hearth extension is not required and
combustible flooring materials may be brought directly up to
the fireplace, many materials (such as wood flooring) may
not tolerate the radiant heat from this fireplace, resulting in
discoloration, shrinking and cracking. For this reason, we
suggest a non - combustible hearth that is no more than 1"
above the bottom of the fireplace. If thicker, fireplace must
be raised accordingly.
Caution: Hearth extensions thicker than 1 "will interfere with
the window frame when opening.
Caution: This fireplace may be recessed up to a m
mum depth of 6, this recess must be constructed ft
non combustible material. The space between the outs
framing edge and the firebox must be completely fre(
any obstructions or debris and the window, with trim
ted, must be able to move freely. No building materi2
permitted to protrude past the framing edges attache(
the fireplace under ANY circumstance.
NON - COMBUSTIBLE
FINISH MATERIAL
0
®Aa
Up to 50 Feet
5 TC42.CE TOWN & COUNTRY 050710 -11
L U% U P V F1 P E P L A C E S
HEARTH WINDOW SUB -FLOOR
EXTENSION TRACK
14 1/2"
FRAMED
OPENINGL
WALL SHIELD THIMBLE
12" VENT PIPE
ELBOW
24" VENT
PIPE
HORIZONTAL
TERMINAL
74 1/4"
* Minimum height from the floor to center of the opening with a
maximum horizontal run of 18" from the center of the flue outlet
to the outside face of the outer wall. The height will need to be
increased if a longer horizontal pipe is required.
0
6 TC42.CE TOWN & COUNTRY 050710 -11
L U X U R V F I R F P L A C E S-
A
Minimum rise
B
Pipe length
C
Maximum run
D
Pipe length
Max.
741/4"
1 -24"
18"
1 -12"
78 112"
1 -12" 1 -18"
75 3/4"
1 -48" 1 -12"
84 112"
1 -24" 1 -12"
11'2"
2 -48" 1 -24"
90 1/2"
1 -24" 1 -18"
1510 1/2"
3 -48" 1 -24"
1 -12"
98 1/4"
1 -48"
20'10 1/2"
5 -48"
For other rise /run combinations see chart below
II dimensions are approximate. Both rise and run may vary with different
,..jbinations of pipe.
48'
MAX.
46'
44'
42'
10'
8'
6'
4 '
24" Pipe
length
minimum
v-- 8 10'
4' 6'
NOTE: The vent must not exceed a total
length of 68 feet. Any combination of rise and
i' 74 1/4" run may be used, but must be constrained to
the boundaries of this chart. A total of four
90° elbows, or combination of other elbows
equalling 90° can be used without reducing
horizontal run. For each additional 90° elbow,
or an equal combination of elbows, reduce
horizontal vent run by 2 feet. Ensure vent pipe
is properly supported.
20'
MAX.
ML
TCVT Wall Vent Cad Drawing
Available at
www .townandcountryfireplaces.com
7 TC42.CE TOWN & COUNTRY 050710 -11
L U X U P V F1 R E P L A C E S
48'
MAX.
46'
44'
42'
10'
8'
6'
A
B
C
D
Minimum rise
Pipe length
Maximum run
Pipe length
minimum
run may be used, but must be constrained to
Maximum
741/4"
1 -24"
29"
1 -12"
78 112"
1 -12" 1 -18"
77 1/4"
1 -48" 1 -12"
84 1/2"
1 -24" 1 -12"
11'11 1/2"
2 -48" 1 -24"
90 1/2"
1 -24" 1 -18"
15,101,
3 -48" 1 -24"
1 -12"
98 1/4"
1 -48"
20'10"
5 -48"
For other rise /run combinations see chart below
** All dimensions are approximate. Both rise and run may vary with different
combinations of pipe.
4' H ----
— i — F - - -; -- 6 ,
I
I I
4'
24" Pipe
NOTE: The vent must not exceed a total
length
length of 68 feet. Any combination of rise and
minimum
run may be used, but must be constrained to
the boundaries of this chart. A total of four
90° elbows, or combination of other elbows
equalling 90° can be used without reducing
horizontal run. For each additional 90° elbow,
or an equal combination of elbows, reduce
horizontal vent run by 2 feet. Ensure vent pipe
pa]
is properly supported.
8 TC42.CE TOWN & COUNTRY
L U X U P V F1 P E P L A C E 5
i
48" Min
TCVT Roof Vent Cad Drawing
Available at
www .townandcountryfireplaces.com
050710 -11
y IL;41.Ut TOWN & COUNTRY 050710 -11
L U X U R Y F1 R E D L 4 C E S
Reach almost any room or commercial setting.
Optional Power Venting allows runs up to 110' from
an outside wall or roof surface. Vent horizontally or
vertically with up to six 90- degree elbows, including
runs up to T below the fireplace.
The premium Power Vent fan runs quietly outside,
at the exterior terminal.
Wall Termination Roof Termination Flush Mount
Horizontal Termination
-1 0
M ��-6 Cad Drawings available at www .townandcountryfireplaces.com
Direct Vent Terminals
Standard Venting Standard Venting Stainless Steel Standard Venting
Roof Termination Wall Termination Termination for Condo Installation
Tj
Cad Drawings available at www .townandcountryfireplaces.com
10 TC42.CE TOWN & COUNTRY 050710 -11
L U X U G V F1 R E D L A C E 5
TOWN & COUNTRY
L U X U P Y F I P E P L A C E S
For personal service pertaining to specific projects, contact:
Town & Country Architect Resource Planner
architects Q pacificenergy.net
Web: www .townandcountryfireplaces.com
Phone: (250) 748 -1184
Toll Free: 1- 877 - 715 -2664
2975 Allenby Road, Duncan, BC Canada V9L 6V8
Printed in Canada
I OWN & COUNTRY
L U X U R Y F1 R E R L A C E 5
EIKLOR FLAMESO
W( CL77' US LOGS SYSTEM
INSTALLATION & OPERATING INSTRUCTIONS
WARNING: If the information in this manual is not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss
of life.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone. Follow
the gas supplier's instructions.
• If you can not reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE
CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE INJURY OR LOSS OF LIFE. REFER
TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION FOR
PROPER INSTALLATION.
FOR YOUR SAFETY
CAUTION
DO NOT STORE OR USE
THIS APPLIANCE MUST BE
GASOLINE OR OTHER
INSTALLED ONLY IN A SOLID -FUEL
FLAMMABLE VAPORS AND
BURNING FIREPLACE WITH A
LIQUIDS IN THE VICINITY OF THIS
WORKING FLUE AND CONSTRUCTED
OR ANY OTHER APPLIANCE.
OF NON - COMBUSTIBLE MATERIAL.
DO NOT INSTALL IN A MANUFACTURERED HOME OR MOBILE HOME.
TABLE OF CONTENTS
TABLE OF CONTENTS ............................. ............................... 2
IMPORTANT INFORMATION .................... ...............................
3
GENERAL INFORMATION ........................ ...............................
5
GENERAL INSTALLATION ....................... ...............................
6
BURNER INSTALLATION INSTRUCTIONS ............................ 7
LOGS INSTALLATION INSTRUCTIONS .. ............................... 9
EXAMPLE OF PROPER POSITIONING OF LOGS & TWIGS10
LIGHTING INSTRUCTIONS .................... ...............................
11
SAFETY PILOT VALVE ........................... ...............................
12
MAINTENANCE ....................................... ...............................
13
TROUBLE SHOOTING GUIDE ................ ...............................
13
SAFETY TESTED AND APPROVED ...... ...............................
14
CUSTOMER SERVICE ............................ ...............................
14
LIFETIME WARRANTY ........................... ...............................
14
THANKYOU! ........................................... ...............................
14
WARRANTY CARD ................................. ...............................
15
Page 2 of 15 EIKLOR FLAMES® Tech Support Hotline: 888.295.5647
IMPORTANT INFORMATION
READ THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING AND
USING THE EIKLOR FLAMESOGAS LOGS SYSTEM
The EIKLOR FLAMES@ Gas Logs System must be installed in a "Class A" fully vented solid -fuel
burning fireplace constructed of non - combustible materials.
Fireplace MUST adhere to non - combustible hearth extending a minimum 20 ", non - combustible lintel
area extending minimum 14 ", noncombustible materials extending 8" on both sides of fireplace
opening.
1. Check the appliance for proper gas type. The type of gas will be marked on the rating
plate.
2. The installation and the provisions for combustion and ventilation air must conform with
the National Fuel Gas Code, ANSI Z223.1 /NFPA 54, or the CSA B 149.1, National Gas
and Propane Installation Code.
3. Solid fuels shall not be burned in a fireplace where a decorative appliance is installed.
4. The minimum permanent free opening of the fireplace chimney damper flue should not
be less than 1 /10 the area of the fireplace opening.
5. The chimney opening must be in a fixed manner to maintain permanent vent opening,
see chart below. To accomplish this, remove damper (if required), install damper stop on
the edge of the damper plate to prevent this accidental closing. NOTE: Damper must be
fully open.
MINIMUM CHIMNEY HEIGHT AND FLUE OPENINGS:
MODEL
CHIMNEY HEIGHT
MIN.FLUE OPENING
MOMBOO
In accordance to local
In accordance to local
38"
codes
codes
6. MINIMUM FIREPLACE OPENING MUST ADHERE TO THE SIZE CHART(S) BELOW:
MOMBOO
MODEL
FIREPLACE
HEIGHT
FIREPLACE
WIDTH
FIREPLACE
DEPTH
BTU
NATURAL
GAS
BTU LIQUID
PROPANE
38"
30"
48"
18"
115,000
115,000
42"
30"
52"
18"
175,000
175,000
48"
30"
58"
18"
200,000
200,000
52"
30"
62"
18"
220,000
220,000
58"
30"
68"
18"
300,000
300,000
64"
30"
74"
18"
325,000
325,000
70"
30"
80"
18"
400,000
400,000
75"
30"
85"
18"
400,000
400,000
Page 3 of 15 EIKLOR FLAMES@ Tech Support Hotline: 888.295.5647
7. A fireplace screen must be in place when the appliance is operating and unless other
provisions for combustion air are provided, the screen shall have an opening(s) for
introduction of combustion air.
8. Gas supply pressures:
NATURAL PROPANE
Minimum inlet supply pressure for the 5.0" w.c. 10.5" w.c.
purpose of input adjustment:
Maximum inlet gas supply pressure: 10.5" w.c. 13.0" w.c.
Manifold pressure: 3.5" w.c. 10.0" w.c.
9. The appliance and its appliance main gate valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in
excess of 1 /2 psi (3.5kPa).
The appliance must be isolated from the gas piping system by closing its equipment
shutoff valve during any pressure testing of the gas supply piping system at test pressure
equal to less than 1 /2 psi (3.5kPa).
10. Keep the appliance area clear and free from combustible materials, gasoline and other
flammable vapors and liquids.
11. Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system
and any gas control which has been under water.
12. The fireplace and venting system (chimney and flue) needs to be inspected and cleaned
once a year by a qualified service technician.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH
WARNING: WHEN USED WITHOUT FRESH AIR, UNIT MAY GIVE OFF
CARBON MONOXIDE, AN ODORLESS, POISONOUS GAS. YOU MUST
MAKE ADEQUATE PROVISIONS FOR ACCESSIBILITY AND FOR
COMBUSTION AND VENTILATION AIR SUPPLY.
31 1_ Z ; �e
Page 4 of 15 EIKLOR FLAMES® Tech Support Hotline: 888.295.5647
GENERAL INFORMATION
TOOLS RECOMMENDED FOR INSTALLATION
Adjustable wrench
Open -end wrench (7/16 ")
Pipe wrench (10.0 ")
Flashlight
Flat blade screwdriver
Open -end wrench (3/4 ")
50/50 soap /water solution
Slip -joint pliers (7.0 ")
Pipe thread sealer,
non - hardening
AS ' SF l Y DR AWING
S to s'
EIKLOR FLAMES RD
MOMBO®
GAS LOG SYSTEM
Size
Dimensions
A
B
C
38"
38
18
12 3 /4
42°
42
18
12
48"
48
18
12
52"
52
18
12
58"
58
18
12
64"
64 3 /4
18
12 3 /4
70"
70
18
12 3 /4
75"
75
18
12 3 /4
W1 Iv ° i �� CR)
Page 5 of 15 EIKLOR FLAMES® Tech Support Hotline: 888.295.5647
GENERAL INSTALLATION
Remove all ashes and debris from the fireplace. Be sure gas supply to the fireplace is in the "OFF"
position. Remove gas log lighter for solid fuel burning fireplace if applicable. Position the damper
stop over the edge of the damper blade and tighten bolt. This should hold the damper partially
"OPEN" in case of an accidental closure. (See Figure 1)
DAMPER STOP
Lr.ivi - LIC — /J / /Jfn
V
A DAMPER AMPER STOP
METAL -ZERO CLEARANCE TYPE BRICK MASONRY TYPE
Figure 1
R r7
Page 6 of 15 EIKLOR FLAMES® Tech Support Hotline: 888.295.5647
BURNER INSTALLATION INSTRUCTIONS
ID THE EIKLORO GAS LOGS SYSTEM MUST BE INSTALLED
BY A LICENSED PLUMBER, LICENSED GAS FITTER, OR IN
SOME LOCALITIES A QUALIFIED SERVICE TECHNICIAN IN
ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL
CODES.
If the gas control valve is installed on the left side of the bumer and the gas supply line comes into
the right side of the fireplace, the gas supply line must continue to the left side of the fireplace (as
close to the rear firebox wall as possible) and terminate behind the gas valve inlet using rigid ' / 2"
black iron pipe. At this point, only the'/" aluminum manifold cab be used to complete the connection
to the gas control valve. It may be necessary to cut and re -flare the aluminum manifold to the
desired length for proper positioning of the burner pan.
1. Remove all ashes and debris from fireplace.
2. Be sure gas control valve to fireplace is in the OFF position.
3. Remove gas log lighter for solid -fuel burning fireplace if applicable.
4. To prevent accidental closing of the fireplace chimney damper, the damper must be:
a. Welded FULLY OPEN or
b. Completely removed or
c. FULLY OPEN using enclosed damper stop installed on the edge of the damper plate.
5. Place your EIKLOR FLAMES@ burner in fireplace with grate spokes toward the front of
fireplace and vertical baffle should be in line with chimney. (See Diagram 1)
CHIMNEY
BAFFLE
IN —LINE WITH
CHIMNEY
Diagram 1
JER
R
E
A
R
Page 7 of 15 EIKLOR FLAMES@ Tech Support Hotline: 888.295.5647
6. For a natural or liquid propane EIKLOR FLAMES® Gas Logs System equipped with a
safety pilot valve system. (See Diagram 2)
i
1/2" BLACK TEE
USED FOR
�PROPANF BURNER
Diagram 2
i�
V A
a. Apply pipe thread sealer to gas supply line coming into fireplace (See Diagram 2,
point A) and install 3 /" x ' /2 " brass supply fitting (See Diagram 2, point 8) and tighten.
b. Install longer end of flared aluminum manifold with 3 /" brass flair nut (See Diagram 2,
point C) to %" x' /2 " brass supply fitting coming into fireplace, and shorter end (See
Diagram 2, point D) to back of gas control valve and tighten.
c. When connections are complete, NEVER TEST FOR GAS LEAKS WITH A LIT
MATCH OR OPEN FLAME. Slowly turn gas control valve to ON position and use
50/50 soap and water solution to test for leaks. Apply 50/50 soap and water solution
with a toothbrush or small paintbrush over all gas connections. A leak will be evident
by observation of bubbles on gas connections. If bubbles are observed, retighten
leaking gas connectors.
Page 8 of 15 EIKLOR FLAMES® Tech Support Hotline: 888.295.5647
LOGS INSTALLATION INSTRUCTIONS
1. Place back log on burner and place front
log on front support. Front and back log
are interchangeable; we recommend using
the longest log in front. (See Diagram 3)
2. Pull front log toward back log to create
1 1/2" space between front log and spokes
of grate. (See Diagram 3)
Diagram 3
3. Place twigs in grooves on top of front and Diagram 4
back log. (See Diagram 4)
4. Using ember material, create thin embers
(small like a penny and thin like a potato
chip) to lightly cover burner pan. Too thick
or too many embers will reduce the
desired glowing effect. Place lava rock up
to and around sides of ember bed to
simulate ashes.
5. Completed view. (See Diagram 4)
WARNING Failure to position items in accordance with these diagrams or failure to
use only parts specifically approved with the EIKLOR FLAMESO Gas Logs System
may result in property damage, personal injury or death.
Fa 57 J_ __� "1;7 �__
Page 9 of 15 EIKLOR FLAMES@ Tech Support Hotline: 888.295.5647
EXAMPLE OF PROPER POSITIONING OF LOGS & TWIGS
MOMBOO Front Log & Back Log Positioning
MOMBOO Large & Small Twigs Positioning
fi C''" DIm ] ° t__
Page 10 of 15 EIKLOR FLAMES@ Tech Support Hotline: 888.295.5647
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push or turn the gas control knob. Never use tools if the knob will not push
in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water, immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas
control which has been under water.
_JJ
Page 11 of 15 EIKLOR FLAMES® Tech Support Hotline: 888.295.5647
SAFETY PILOT VALVE
1. To prevent accidental closing of the fireplace chimney damper, fireplace chimney damper
must be:
a. Welded FULLY OPEN or
b. Completely removed or
c. FULLY OPEN using enclosed damper stop installed on edge of damper plate.
2. For natural or liquid propane Eiklor Flames® Logs System with a safety pilot valve:
NATURAL GAS or LIQUID PROPANE
a. Read safety information label located on top of gas control
valve.
b. Find pilot mounted on left side of burner.
PILOT position
c. PUSH IN gas control knob and turn it counterclockwise to
PILOT, keep gas control knob PUSHED IN and
immediately light pilot with a match.
d. After pilot is lit, continue holding gas control knob in the
PUSHED IN position for approximately one (1) minute to
bleed air from the gas supply line and to prove the pilot.
e. Release gas control knob and pilot should remain lit. If gas
control knob does not pop up when released, STOP and
immediately call a qualified service technician or gas
supplier. If pilot will not remain lit after several tries, turn the
gas control knob clockwise to the OFF position and call a
qualified service technician or gas supplier. t'
f. After pilot is lit, turn gas valve control knob
counterclockwise to the ON position.
ON position
3. Keep glass doors OPEN during operation and have fireplace
screen CLOSED during operation.
4. To turn the MOMBOO Gas Logs System OFF:
a. Turn the gas control valve clockwise - to the OFF position,
pilot and main burner will extinguish.
OFF position
- FM) F-0- k - Avt I i _ zj i cl
Page 12 of 15 EIKLOR FLAMES® Tech Support Hotline: 888.295.5647
MAINTENANCE
Your EIKLOR FLAMESO Gas Logs System will last a lifetime, but periodic maintenance (at
least once a year) is recommended. EIKLOR FLAMESO authorized dealers are always
available to help. They will clean and adjust your burner and gas control valve and make
sure that everything is working properly. They will clean your logs; heavy soot build up on
your logs should be removed, but a light soot build up is desired for a realistic appearance.
Soot can be removed with a small paintbrush or vacuum cleaner; do not vacuum the
SUNGRO horticulture vermiculite, embers or lava rock.
Can you clean it yourself? Yes you can if you have the proper training! Safety is of prime
concern so we recommended that you call your EIKLOR FLAMES@ authorized dealer for
proper maintenance. If an EIKLOR FLAMES@ authorized dealer is unavailable, call us
directly at 888 - 295 -5647 and we will promptly answer your call.
TROUBLE SHOOTING GUIDE
PROBLEM REASON SOLUTION
Pilot will not light Air in gas supply line Bleed gas supply line
Pilot hood blocked Check for debris or dirt
Clean pilot
Low gas pressure Make sure manual gas control valve is in the ON position
Check gas line for size and blockage
Dirty pilot Pilot should be blue and hitting the thermocouple properly
Clean pilot
Pilot will not stay lit Pilot hood not aimed at Pilot hood bent; replace pilot or angle pilot hood properly so
thermocouple pilot flame hits thermocouple '/2" below tip of thermocouple
Pilot line bent Replace pilot line
Thermocouple is loose Tighten thermocouple nut at gas control valve
Thermocouple cracked Replace thermocouple
Thermocouple worn out Replace thermocouple
Excessive down draft Install chimney cap
Outside Chimney too close to other peaks
Check chimney flue for proper height
PoorIv desi ned chimne
Gas logs burner goes Low gas pressure; pilot Make sure manual gas control valve is in the ON position
out fades Dirty pilot
Gas line sized improperly
Thermocouple is loose Tighten thermocouple nut at gas control valve
Thermocouple worn out Replace thermocouple
/_�
Page 13 of 15 EIKLOR FLAMES(g) Tech Support Hotline: 888.295.5647
SAFETY TESTED AND APPROVED
Your EIKLOR FLAMES@ Gas Logs System is safety tested and approved by CSA
International to ANSI Z21.60 b — 2004.
Q ES I B,�
nF LE F!ii icD /
CUSTOMER SERVICE
EIKLOR FLAMES@ is committed to customer service and exceeding customer expectations.
We are available Monday — Friday 8:30 AM — 5:00 PM EST toll -free @ 888 - 295 -5647 to
provide technical assistance and to answer any questions you may have regarding our
products.
LIFETIME WARRANTY
Our 20+ years of success is the result of exceeding customer expectations and as we look
ahead, this principle remains at the core of our culture. Our continued strong performance is
achieved by our manufacturing excellence.
You have a LIFETIME WARRANTY with our products, our continuing commitment to our
customers. If you should accidentally break a log, or any issue you may have with your
EIKLOR FLAMES@ Gas Logs System, please call your EIKLOR FLAMES@ authorized
dealer, and if your dealer is unavailable, call us at 888 - 295 -5647 and we will promptly answer
your call. It is important for you to register your EIKLOR FLAMES@ Gas Logs System with
us, so please complete the warranty card on Page 17 of this owner's manual and send it
back to us via mail or facsimile.
1. Your MOMBOO burner system has a lifetime warranty. Your MOMBOO gas logs have
a 1 year warranty if burned as recommended in intervals of 4 hours on an 1 hour off.
2. If your MOMBOO Gas Logs System was purchased with a gas control valve factory
mounted at EIKLOR FLAMES@ the gas control valve has a one -year warranty
against any performance defects. If your MOMBOO Gas Logs System was purchased
with a gas control valve not factory mounted at EIKLOR FLAMESO the gas control
has no warranty.
3. All painted surfaces that get wet due to rain, flooding, household pets, wild animals or
birds; or that get damaged due to negligence or disaster have no warranty.
4. Embers and lava rock that get wet due to rain, flooding, household pets, wild animals
or birds; or get damaged due to negligence or disaster, have no warranty.
THANK YOU
Please accept our thanks for choosing the EIKLOR FLAMES@ Gas Logs System for your
fireplace. We will continue to do everything possible to merit your confidence you have in our
products.
Page 14 of 15 EIKLOR FLAMES@ Tech Support Hotline: 888.295.5647
EIKLOR FLAMES @
WARRANTY CARD (WE NEED YOUR INFORMATION)
Your information
Name:
City, State:
Phone number:
MOMBO® Gas Logs System size:
Control valve type:
Control valve factory mounted at EIKLOR FLAMES®: Yes No
Gas type: Natural Gas Liquid Propane
Usage: Residential Commercial
What is your fireplace design Front View See -Thru 3 -Sided 4 -Sided
Your hand - written comments
Purchased from
Date of purchase:
Name:
City, State:
Phone number:
Installed by
Name:
City, State:
Phone number:
282 E. Pivot Point Road
Paoli, IN 47454 U..S.A.
Toll -Free: 888.295.5647 Phone: 812.723.3633
Fax: 812.723.5708
Website: www.eiklorflames.com