Loading...
HomeMy WebLinkAboutE09-0174NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES TOWiYOFVAa ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit #: E09 -0174 ASFR Project #: Job Address: 1468 VAIL VALLEY DR VAIL Status ... Location.....: Applied. . Parcel No...: 210109207015 Issued . . Expires. .: OWNER REVOCABLE TRUST FOR BAHMAN A 09/15/2009 8745 OLD DOMINION DR MCLEAN VA 22102 APPLICANT DAVE PETERSON ELECTRIC 09/15/2009 Phone: 970 - 926 -4140 P.O. BOX 711 EDWARDS CO 81632 License: 119 -E CONTRACTOR DAVE PETERSON ELECTRIC 09/15/2009 Phone: 970 - 926 -4140 P.O. BOX 711 EDWARDS CO 81632 License: 119 -E Desciption: WIRING FOR REMODEL TO CONVERT TWO- FAMILY DWELLING TO SINGLE - FAMILY DWELLING Valuation: $35,000.00 Square feet: 3500 PRJ08 -0295 ISSUED 09/15/2009 09/16/2009 03/15/2010 FEE SUMMARY Electrical Permit Fee --------- > $155.25 Total Calculated Fees - -> $159.25 Investigation Fee--------- - - - - -> $0.00 Additional Fees ---------- > $0.00 Will Call Fee--------------- - - - - -> $4.00 Use Tax Fee ------------------- > $0.00 TOTAL PERMIT FEE --- > $159.25 Total Calculated Fees ------- > $159.25 Payments------------ - - - - -> $159.25 BALANCE DUE ---------- > $0.00 APPROVALS Item: 06000 ELECTRICAL DEPARTMENT 09/15/2009 JLE Action: AP CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. ;TS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR FROM 8:00 A - " ;W Signature of Owner or Contractor bate Print Name elec_prm_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R090001229 Amount: $159.25 09/16/200912:59 PM Payment Method: Check Init: SAB Notation: 25479 -DAVE PETERSON Permit No: E09 -0174 Type: ELECTRICAL PERMIT Parcel No: 2101 - 092 - 0701 -5 Site Address: 1468 VAIL VALLEY DR VAIL Location: Total Fees: $159.25 This Payment: $159.25 Total ALL Pmts: $159.25 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- EP 00100003111100 ELECTRICAL PERMIT FEES 155.25 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ELECTRICAL PERMIT Pro ect Street Address: (Number) (Street) (Suite #) Building /Complex Name: D./1IUJ41C k010))0s Contractor Information: Company: _7 C Company Address: City: ft M -b5 State: Zip: G/ Contact Name: 1)k 6,F_ Contact Phone: 270 / L(�'� 7 Y� E -Mail dot G' 6) G) LIE Pe /'e i -SOl%e i° -1"),`0 m0 a,) /f) Tow)l of Vail Contractor Registration No.: '✓ Contractor Signature (required) Property Information �y Parcel #: (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Owner Name: b, P' ,--i r_ COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUA- TION OF WORK (Labor & Material) Amount of SQ Ft.: L' 00 Electrical $: L ......... .............. J;%, —75- Office Use: DZ3 Project #: ©� �(� r 0 Building Permit #: 0 (�//,� —d Electrical Permit #: C,Q"1 f A l l t %J!} TTFr? ML N Lot #: Block # Subdivision: VzLi,,I -( 61 Detailed Description of Work: Ab lgt'l G1,6 EGEGT /z LC SC'/�L'T (use additional sheet ifhecessary) Work Class: New ( ) Addition ( Remodel( ) Repair( ) Other( ) Type of Building: Single - Family ( ) Duplex Multi - Family ( ) Commercial ( ) Restaurant( ) Othe ( ) Date Received: 2009 i I TOWN, F VAIL. 29- May -09 � o - - - - --- ____------------ - - - - -- _.Page 5 5-03 -2010 Inspection Request Reporting -AR nm ' Vail_ CQ_ »_..C.11V_9 -- - - - -- Requested Inspect Date: Tuesday, May 04, 2010 Inspection Area: SH Site Address: 1468 VAIL VALLEY DR VAIL A /P /D Information Activity: E09 -0174 Type: B -ELEC Sub Type: ASFR Status: ISSUED Const Type: Occupanc�yy; Use: Insp Area: SH Owner: REVOCABLE TRUST FOR BAHMAN ATEFI Contractor: DAVE PETERSON ELECTRIC Phone: 970 - 926 -4140 Description: WIRING FOR REMODEL TO CONVERT TWO- FAMILY DWELLING TO SINGLE- FAMILY DWELLING Reauested Inspection Item: Requestor: Comments: Assigned To: Action: 190 ELEC -Final DAVE PETERSON ELECTRIC 904 -6369 JMONDRAGON ��-•i _ � Time Exp: Requested Time: 08:00 AM Phone: 970 - 926 -4140 -or- cell 904.. 6369 Entered By: JMONDRAGON K f l" F � { r . l -" f ' .o � .�F� ,K' ,! ' "%ice � ,� � � " y _..._2 -•n 1. 1 / t ' �':? ,y j l � .-r� J J r^ f ' f Inspection History Item; 110 ELEC - Service ** Approved ** AP APPROVED C Item: 120 E Item: 130 ELEC -Con 10/22/0 Comment Item: 140 ELEC -Mist. Item: 190 ELEC -Final REPT131 Inspector: MDENNEY Action. Inspector: mdenney Action: AP APPROVED 200 AMP TEMP pp ** h Inspector: MDEMY Action: AP APPROVED duit ** Approved ** 9 Inspector: MDENNEY Action: PA PARTIAL APPROVAL NORTH E CNDUI OF ROAD TMTRANSFORMER UNDER ROAD TO PROPERTY /e Gx k 1 E..,.,t. NEED TO Y71 /Y` Run Id: 11356 TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Job Address: 1468 VAIL VALLEY DR VAIL Location.....: Parcel No...: 210109207015 Project No OWNER REVOCABLE TRUST FOR BAHMAN A 10/23/2009 8745 OLD DOMINION DR 10/23/2009 MCLEAN 10/28/2009 VA 22102 04/26/2010 APPLICANT THUL ELECTRONIC SYSTEMS 10/23/2009 P 0 BOX 534 AVON CO 81620 License: 112 -S CONTRACTOR THUL ELECTRONIC SYSTEMS 10/23/2009 P 0 BOX 534 AVON CO 81620 License: 112 -S Permit #: A09 -0083 Status . . . : ISSUED Applied..: 10/23/2009 Issued . .: 10/28/2009 Expires . .: 04/26/2010 Phone: 970 - 949 -4638 Phone: 970 - 949 -4638 Desciption: REMODEL TO CONVERT TWO- FAMILY DWELLING TO SINGLE FAMILY DWELLING: INSTALL FIRE ALARM SYSTEM Valuation: $2,500.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ***************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Electrical --------- > $0.00 Total Calculated Fees - -> $381.75 DRB Fee --------- > $ 0 .00 Additional Fees ---------- > $ 0 . 00 Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $381.75 Will Call --------- > $0.00 Payments ------------------ > $381.75 TOTAL FEES - -> $381.75 BALANCE DUE--- - - - - -> $0.00 ****************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Approvals: Item: 05600 FIRE DEPARTMENT 10/28/2009 mvaughan Action: AP add device in elevator control room. Identify beam depth in master suite. ****************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CONDITIONS OF APPROVAL Cond: 52 Monitored fire alarm system required and shall comply with NFPA 72 (2002 ed.) and VFES Standards ****************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHON ) 97 - 479 -2252 FROM 8:00 AM - 5 PM. l SET RECEIPT RECEIPT NUMBER: R090001557 SET ID: S000000171 SET NAME: Temp set of Type ACTIVITY TRANSACTION DATE: 10/28/2009 TOTAL PAYMENT: 381.75 TOTAL PAID FROM TRUST: .00 TOTAL PAID FROM CURRENCY: 381.75 SET TRANSACTIONS: Set Member Amount ---- - - - - -- ------ - - - - -- A09 -0083 381.75 TOTAL: 381.75 TRANSACTION LIST: Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- Payment Check 17297 381.75 TOTAL: 381.75 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- --- ------- - - - - -- ------ - - - - -- FIRE ALARM PERMIT FEES BP 0010000311110 93.75 PLAN CHECK FEES PF 0010000311230 288.00 TOTAL: 381.75 RECEIPT ISSUED BY: SBELLM INITIALS: SAB ENTERED DATE: 10/28/2009 TIME: 11:16 AM FIRE ALARM PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include information listed on the 2nd page of this form. Application will not be accepted without this information. ............................................................................................................................ ............................... Project/Street Address f rrTQ �=+ {, S 1 C Y� C �0 fit% V CI. �t/1,tr.. Contractor Informatiopn: 1 _ Company:tiX� ik�. l�&Y- Company 1. Yl 1 G S Address: +' L° City: A410 �, State: 00 Zip: ,� t (D 2 b Contact Name: i'1 bC?� i L C7 Contact Ph: ft ' q 4 q 4' 6 Cell: E -Mail NtC 5 C.x�W1 Town of Vai ntractoRegistration No.: _ �11� Contractor siana(ure Property Information Parcel #:i ®�� Legal Description: Lot #: r 1 Block #: Subdivision: Building /Complex Name: �Cal\MC+`� Owner Name: Y u,j (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecouty.us/pate) :......................................................................................... Does a Fire Alarm Exist? ................ .... ..... ... ............................... . Yes ( ) No (�) Does a Sprinkler System Exist? Yes ( ) NoY( i) ....................................................................../.. �.. �.... �................ ............................... Project Building Permit* Alarm Permit #: Detailed Description of Work: J OLLY M 5 (use additional sheet if necessary) Value of Fire Alarm: (Labor & Materials) Work Class: New (V/) Addition Repair( ) Other( Remodel( ) Retro -Fit ( ) ................................................................................... ............................... Work Type: Interior {%) Exterior( ) Both ( ) Type of Building: Single- Family) Duplex { } Multi - Family { } Commercial ( ) Restaurant ( ) Other ( ) .................................................................................. ............................... Date Received: .. ........................... 'VA 1i FIU.r D Ep... Approved as Submitted Q D Approved as Noted -_4 n Date: 0 to - "_ CT 2 2 2009 NN OF VAIL Honeywell's VISTA -50P Control Panel provides the flexibility of up to eight independent partitions with the economy of a single control. FEATURES Dependable features to meet your most demanding installations: • Nine hardwired zones standard • Expandable to 87 total zones • Eight partitions standard • 75 user codes work in all partitions • Seven authority levels • 224 event memory log /printer option • Four trigger outputs • 5800 Series wireless compatibility • Supports two -wire multiplex • Scheduling of events (real time clock) • Keypad macro features • Master console option for viewing all partitions at a glance • Common lobby logic • Fast downloading • Supports up to 16 relays and /or X -10 • Quick start programming • False alarm features • UL Commercial Burglary listed (VISTA- 50PUL) End users will appreciate the easy -to -use convenience and control features of the VISTA -50P: • Wireless remote controls (featuring single button system operation): — 5804 - Four -Button Wireless Key — 5804BD - Bidirectional Four - Button Wireless Key with system status feedback • Single or dual -button wireless personal panic: — 5802MN — 5802MN2 • Home control features activate lights, appliances, garage doors and numerous other devices • The VISTA Interactive Phone Module (VIP) gives the end -user control of their system from any touchtone phone. The 4286 VIP responds in English, with a vocabulary of over 100 words • Full English display keypads for clear understanding of system status and zone locations • Timed event applications: — Opens garage doors and turns on lights — Provides "lived -in look" while away from home — Ability to limit access to parts of the home at certain times VISTA -50P CONTROL PANEL SPECIFICATIONS Electrical • Aux power 12VDC, 750mA max • 16.5 VAC /40 VA transformer • Alarm output 12VDC, 1.7 Amps max • For UL installations, combined Aux and alarm output cannot exceed 750mA Output Control • Supports up to four relay boards (Part No. 4204) • Each board supports four relays for a total of 16 • Optional X -10 interface (Part No. 4300) may be used to control X -10 receiving devices • Each X -10 receiver address counts as one relay when computing total relays • Real time clock can be used for relay/X -10 control Zones • Nine hardwired zones • Selectable response on zone 9: 10MSec or 500MSec • Assignable to any partition • 14 zone types to choose from • Programmable swinger suppression Communications • Touchtone or pulse • Formats supported: ADEMCO Contact ID, ADEMCO 4 + 2 Express, ADEMCO low speed • 3 +1, 4 +1 and 4 +2 reporting • Reporting capabilities: Split, Dual, Split /Dual • Low battery reports 11.2- 11.6VDC • Expanded reporting • Up to four digit PABX codes supported • True dial tone detection • Double pole line seizure • AC loss and restoral reporting supported Supported Devices Hardwired Expansion Devices • 4208U Eight -Zone Expansion Module • Keypads — 6139 Custom English (required for programming) -100mA — 6128 Fixed English LCD - 30mA • Voice Module 4286 VIP -160mA • Two -Wire Smoke Detectors • Duct Detectors • Serial Printer • Polling Loop Devices • Key Switch Devices Wireless Receiver Systems • 5800 Series — 5881 ENL up to 8 zones -50mA — 5881 ENM up to 16 zones -50mA — 5881 ENH up to 26 zones -50mA • All Receivers Support: — Diversity reception with two antennea — Remote mounting for best location — Use of second receiver for maximum coverage or tough installations — Unique supervision and low battery indications by point Transmitters • 5800 Series — Three volt Duracell lithium batteries — One mile range — Tamper standard Agency Listings • UL Residential Fire and Burglary and CSFM • UL Commercial Burglary (VISTA- 50PUL) ORDERING VISTA -50P Control Panel Automation and Control Solutions Honeywell Security & Communications w uO��`A�� 2 Corporate Center Dr. Suite 100 ■ ■ J P.O. Box 9040 Melville, NY 11747 LNS50PD Septwba 2008 www.honeywell.com 0 2008 H«,ey�u lrt nacionai tnc. The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white console blends with any decor and features a contoured, removable door that conceals illuminated soft -touch keys. The 6160 also features a new larger and brighter 32- character display with easy -to -read plain - English status messages. FEATURES • Large, easy -to -use keypad • Keys continuously backlit for greater visibility • Speaker with audible beeps to indicate: System status Entry/exit delay Other alarm situations SPECIFICATIONS Physical • 5- 5/16 "H x 7 -3/8 "W x 1- 3/16 "D (135mm x 190mm x 30mm) The oversized function keys are easily accessed even when the keypad door is closed, and can be programmed for fire, burglary, personal emergencies and other operations. Colored self- adhesive labels are included. • Zones and system events displayed in plain English • No confusing blinking lights • Four programmable function keys Wiring • - (Black): Ground • + (Red): +12 VDC (Aux. Power) Current • D1 (Green): "Data in" to control panel • Standby -40mA • DO (Yellow): "Data out" from • Activated Transmission- 1 60mA control panel ORDERING 6160 Alpha Display Keypad Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 ccosoi0 Syosset, NY 11791 u6160/D September 2006 www.honeywell.com 0 2006 Honeywel Intemationd Inc. • System functions clearly labeled • Functions performed by just entering security code plus command • White with removable door blends with any decor Compatibility • Fully compatible with all VISTA controls. nomlywell 5192 . . \ IL c An ADEMCO Group Company Smoke Detector 5 The ADEMCO 5192 Series low profile, addressable V- PlexTm smoke detectors deliver state -of the -art features and benefits in a cost - effective package_ These detectors are designed to provide open area coverage and are compatible with ADEMCO's VISTA controls supporting V- Plex technology. An LED on the detector will blink periodically during normal conditions, remain on steady during alarm and cease to pulse if the chamber is out of acceptable sensitivity range. An extremely powerful feature available within the 5192 Series is the Automatic Maintenance Alert/Reporting capability - a feature normally found in today's high end analog addressable systems. The detectors continually monitor their own sensitivity levels in addition to the basic normal and alarm conditions. These HIGH and LOW SENSITIVITY signals are communicated back to the control, via the V -Plex addressable loop, to indicate locally and at the central station that the detector may not be able to detect smoke or may false alarm. This feature works with Vista- 32FB,128FB, 1288 and First Alert Professional FA1600C. More important is the cost saving associated with Automatic Maintenance Reporting. The feature is an approved alternate to NFPA 72 field sensitivity calibration testing that require external test meters. This eliminates the need to schedule inspections to determine detector sensitivity /viability. Another important benefit of these V -Plex (addressable) smoke detectors is their ability to operate on existing wiring. There is no need to run special twisted pair, data grade or shielded wires, providing you with the right choice for all your retrofit applications. That equates to cost savings in time and materials! FEATURES: ♦ Low profile design ♦ V- PlexTrm addressable loop device ♦ Automatic maintenance reporting ♦ Available with integral heat sensor ♦ Simple 2 wire installation ♦ Tamper resistant ♦ DIP switch or serial number programmable ♦ Lines on existing or conventional wiring APPLICATIONS The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection applications. These smoke detectors are compatible with all ADEMCO VISTA Fire and Burglary controls that support V -Plex addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications. They are suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or professional office suites and in factory and warehouse environments. .ii.•lllJllU.i �i.�� %f. � / % /� Fir/. . •fii =l xi % •i% 6 •::v.;,:D GF1QUP COMMERCIAL SYSTEMS OMSION An ADEMCO Group Company INSTALLATION The 5192 Series smoke detectors are supplied with a convenient mounting bracket that allows the detector to be mounted to a variety of electrical junction boxes. A removable terminal hlnrk that arrants 14 to 22 gauge wire to w .i.. Wiring diagram for 5192SD /SDT smoke detector .................................. I........ Ordering Information Pall No. Description 5192SD Addressable Photoelectric Smoke Detector 5192SDT Addressable Photoelectric Smoke Detector w /Integral Heat Sensor provide easy wiring connections. The detectors are designed to meet all applicable requirements for UL Commercial and Residential Fire installations as well as NFPA 72 requirements when installed in compliance with the National Electric Code and approved /listed control panels. COMPATIBILITY These smoke detectors are compatible with all VISTA control panels that support V -Plex (addressable) polling loop technology. The detectors support DIP switch or serial number addressing. DIP switch configuration are compatible with 5140XM, VISTA -40, and VISTA - 50P controls. Serial number addressing is supported on VISTA -32FB, VISTA -100, VISTA - 128FB, VISTA -128B and First Alert Professionals FA1600C controls. Refer to control panel and smoke detector installation instructions for details. Automatic Maintenance Reporting Compatibility The automatic maintenance feature is compatible on with the following control panels ONLY VISTA -32FB (coming soon), VISTA - 1281`13, VISTA - 128B and First Alert Professionals FA1600C. The automatic maintenance may be disabled for all other controls that do not support this feature. Refer to control panel and smoke detector Installation Instructions for details. SPECIFICATIONS Electrical: System voltage range: Standby current (maximum @ 12V): • LED off: 1.2mA • LED on: 2.8mA Mechanical: Diameter. ♦ 5.5 inches (140mm) (including mounting bracket) Height: ♦ 1.7 inches (43mm) (including mounting bracket) Weight: ♦ 5.3 ounces (150 grams) Environmental: Installation temperature range: ♦ 32° to 100 °F (0° to 38 °C) Installation humidity range: ♦ 10% to 93% RH, non - condensing Heat sensor (5192SDT only): ♦ 135° fixed temperature electronic thermistor EMI: • Meets or exceeds the following requirements: • FCC Part 15, Class B Device • IEC EMC Directive AGENCY LISTINGS Fire: • UL268 Commercial System Smoke Detector • Meets OF 217 Requirements for Residential Applications • Factory Mutual(Pending) • California State Fire Marshall • MEA (Pending) COMPATIBLE DEVICES • VISTA -40 Partitioned System *(Residential Fire) • VISTA -50P and VISTA -50PUL Partitioned System *(Residential Fire) • VISTA -100 Integrated Fire /Burglary Control *(Commercial Fire) • VISTA -128FB Integrated Fire /Burglary Control (Commercial Fire) • VISTA -128B Partitioned Burglary Control (Residential Fire) • VISTA -32FB Integrated Fire /Burglary Control (Commercial Fire Pending) *Automatic Maintenance Reporting feature not supported by control panel ♦7 -14V y!f fi IN 165 Eileen Way, Syosset, New York 11791 • Copyright ©1998 Pittway Corporation A% ^ :.r'f "`� ? '` "r: 1 ADEMCO is an IS09001 Registered Company '� "` "` ` "` L/5192lD 1199 G R O P U COMMERCIAL SYSTEMS DIVISION a z— — w I �o D W +' ° `JJ- Cn co DIP =/ r SWITCH REMOVABLE (r} a- TERMINAL BLOCK 0 , U Wiring diagram for 5192SD /SDT smoke detector .................................. I........ Ordering Information Pall No. Description 5192SD Addressable Photoelectric Smoke Detector 5192SDT Addressable Photoelectric Smoke Detector w /Integral Heat Sensor provide easy wiring connections. The detectors are designed to meet all applicable requirements for UL Commercial and Residential Fire installations as well as NFPA 72 requirements when installed in compliance with the National Electric Code and approved /listed control panels. COMPATIBILITY These smoke detectors are compatible with all VISTA control panels that support V -Plex (addressable) polling loop technology. The detectors support DIP switch or serial number addressing. DIP switch configuration are compatible with 5140XM, VISTA -40, and VISTA - 50P controls. Serial number addressing is supported on VISTA -32FB, VISTA -100, VISTA - 128FB, VISTA -128B and First Alert Professionals FA1600C controls. Refer to control panel and smoke detector installation instructions for details. Automatic Maintenance Reporting Compatibility The automatic maintenance feature is compatible on with the following control panels ONLY VISTA -32FB (coming soon), VISTA - 1281`13, VISTA - 128B and First Alert Professionals FA1600C. The automatic maintenance may be disabled for all other controls that do not support this feature. Refer to control panel and smoke detector Installation Instructions for details. SPECIFICATIONS Electrical: System voltage range: Standby current (maximum @ 12V): • LED off: 1.2mA • LED on: 2.8mA Mechanical: Diameter. ♦ 5.5 inches (140mm) (including mounting bracket) Height: ♦ 1.7 inches (43mm) (including mounting bracket) Weight: ♦ 5.3 ounces (150 grams) Environmental: Installation temperature range: ♦ 32° to 100 °F (0° to 38 °C) Installation humidity range: ♦ 10% to 93% RH, non - condensing Heat sensor (5192SDT only): ♦ 135° fixed temperature electronic thermistor EMI: • Meets or exceeds the following requirements: • FCC Part 15, Class B Device • IEC EMC Directive AGENCY LISTINGS Fire: • UL268 Commercial System Smoke Detector • Meets OF 217 Requirements for Residential Applications • Factory Mutual(Pending) • California State Fire Marshall • MEA (Pending) COMPATIBLE DEVICES • VISTA -40 Partitioned System *(Residential Fire) • VISTA -50P and VISTA -50PUL Partitioned System *(Residential Fire) • VISTA -100 Integrated Fire /Burglary Control *(Commercial Fire) • VISTA -128FB Integrated Fire /Burglary Control (Commercial Fire) • VISTA -128B Partitioned Burglary Control (Residential Fire) • VISTA -32FB Integrated Fire /Burglary Control (Commercial Fire Pending) *Automatic Maintenance Reporting feature not supported by control panel ♦7 -14V y!f fi IN 165 Eileen Way, Syosset, New York 11791 • Copyright ©1998 Pittway Corporation A% ^ :.r'f "`� ? '` "r: 1 ADEMCO is an IS09001 Registered Company '� "` "` ` "` L/5192lD 1199 G R O P U COMMERCIAL SYSTEMS DIVISION - nw 5600 Series Mechanical Neat Detectors System Sensor's 5600 series mechanical heat detectors o!fera io;,A­cost mearis forpfc-peftypfc-teCiion ay^a ins t �r, ; and for non - life- safetvinstallations where smoke detectors are inappropriate. Features Multiple configurations for installations: - Single- and dual- circuit models - Fix<:d iernp and cornhinaiion fixed - ton" :p4atc of rise 135'F or 194'F ratings- Plain housing for residential installations (Model 5601 P) Easy -to -use terminal screws A broad range of back box mounting options: - Single gang - 35° and 4" Octagonal square vvitl s,.ivare t(-; r•)und plaster ring Reversible mounting bracket Agency Listings @ < <FM > M Multiple configurations. The 5c : Ci series offers a full - Iine of conhgurations to acc"niModate oroad range •,f aoplicatiuns. [loth single- and dual- circuit models are available for low- and high - temperature ravings with either fixed temperature <:r cornhination I1Xed CempefatiirE'.irate- C'i -rise (RIO R) IOn. T h^ Rt�F e2iemenl: Ci t he -ixedlRUR models is aesicnable to accarnr�rocate iieb :j tesrinc:. Installation flexibillty.To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four - square back boxes, when used with a square to round plaster ring.The reversible mounting bracket : _lrrnits hoih f:ush and surface murn-;t ,ack box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Farr; ter nperaturr. models are id <nt `ed FX, lvhil nmhinaion hxed/raie r :f rise -ir:ia r..< rnzi!ked FX /RG tTh:, > .00 series also provides a post - activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems The detector shall be either a single- circuit or a dual- circuit type, normally open. The detector shall be rated for activation at either 135-- (57'C) or 194°F (1>0 °C), and shall ac' -svate by nteans of a fixed ternl;erature• t: err:-al r.ns;r, Of a'xieihiration fixes l jre/ rate of rise therrnA sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15 °F (8.3 °C) per minute. The detector shall include a reversible mounting bracket for mounting to 316-inch and 4 -inch octagonal, single gang, and 4 -inch square back boxes with a square to round plaster ring. Wring connections shall be made by means of SEMS screws that shall accommodate 14 -22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature stir g and activation me -shod. the rate of -rise e iornert of comnirlation fixer) temneiaute %raft -- v' -i ise rrode:s tal: be restordble., to aloe,, for field- ;e, -;ng. The d(tr- -ctors sh7:f include an exte na collector that shall drop u:)on : tivatiorl to, identify thr_ i)nit in al:�rrr. } r�''! ��'+•{;< •�,'`C�`ttS'�+'�+.z:'3�.ti''-<U. - �'-,'3y�; '�•K�.R':�R�+�; �.t:;•,t. «spa {� {/S c;,o- '':{ r,..• '�J�"�����s!�fl�Y<GRf�SCp�� � /i /arlii /.Gihlii /iu i6itir /iiiinir /iif�iif i r / O /f /. ri i .i:r }J:. -.r R•. Maximum Installation Temperature 5601 P, 5603,562 1, and 5623: 100 °F (38 °C) 5602, 5604, 5622, and 5624: 1 WE (65.6 °C) Operating Humidity Range 5 to 95% RH non - condensing Dimensions with mounting bracket Diameter: 4.57 inches O1.6cm) Height 1.69 inches (43cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 13S °F (57 °C) T 5602, 56G4,5622, and 5624:194'F (90 °C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15 °F (8.3 °C) rise per minute (models 5601 P, 5602,562 1, and 5622 only) Mounting 3' /2-inch octagonal back box 4- inch octagonal back box Single gang back box 4 -inch square back box with a square to round plaster ring Operating Voltage / Contact Ratings 6- 125VAC / 3A 6 -28VDC / 1 A 125VDC / 03A 25OVDC /0.1A --------------------- -- ---- ----- ------ -- ------ - - - --- ---- ----- ---- - -- - - -- - Input Terminals 14 -22 AWG t� t n i Ord u S601 5602,5622 5603,5623 5604,5624 5621 Information 5601 P Single None 135°F (57C) Fixed Temperature/ Rate -of Rise 50 feet x 50 feet (115 241n x 15.2m) -------------------- -- ---- -- ------ --- ---- -- -- -- - --- ------------------------------------------------------------------------------------ --- --------- ---------------------- -- ---- ------ ---- -- -- -- ------ - 5602 Single Lettering 194 °F (90 °C) Fixed Temperature /Rate of -Rise 50 feet x 50 feet (15 -24m x 15 -2m) - - -- - ---- -- -- --- --- 5603 Single Lettering 135°F (57 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7 62rn) 5604 Single Lettering 194 °F (90 °C) Fixed temperature 25 feet x 25 feet (7 -62m x 7 -52rn) 5621 Dual Lettering 135 °F (57 °C) Fixed temperature/ Rate -of Rise 50 feet SO feet (IS 24m x 15.2m) ------ - - - --- --- -- ------------ - - - --- ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 5622 Dual Lettering 1947 (90 °Q Fixed Temperature / Rate- of-Rise 50 feet x SO feet (15 -24m x 15 -2m) 5623 Dual Lettering 135 °F (57 °C) Fixed Temperature 25 feet x 25 feet (7 62m x 7.62m) 5624 Dual Lettering 194 °F (90°Q Fixed Temperature "NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. •MA 3825 Ohio Avenue • St. Charles, IL 60174 r °y _3 � Phone: 800- SENSOR2 • Fax 630 377 -6495 25 feet x 25 feet (7.62rn x 7 62m) 02COG System Senso, cufre PFOJx 1 kxn Un,m Iud -ny the latest It mk oat'r_t. ADS 6351 002 11.OG -01626 Installation instructions 4193SN Serialized Interface Module (SIM) The 4193SN is a serialized two -zone expander used to connect alarm sensing devices to controls which support serial number polling loop devices (i.e., Vista - 40, Vista -50P, and Vista -100). The 4193SN can be configured as one supervised zone (10K EOLR) and one unsupervised zone, or two unsupervised zones (normally closed devices only). Consult the control panel installation instructions for programming information. Electrical Specification: Voltage: 7 -11VDC (as supplied from the Ademco control panel for multiplex polling loop) Current: 1.5mA RED ( +) WHITE (LOOP 1) SUPERVISED EOLR 10K YELLOW (LOOP 1) UNSUPERVISED POLLING LOOP GREEN (LOOP 2) UNSUPERVISED BLACK ( -) I I BLACK (COMMON) Wiring Diagram S U LISTED 5789 For Fire Applications: The 4193SN must be mounted inside the control panel cabinet or inside a UL- Listed junction box. Loop 1 must be used in the supervised configuration for Fire. Loop 2 may be used for Burglary. For UL Burglary Applications: If using an unsupervised zone of the 4193SN, the unit must be mounted within 3 feet of the alarm initiating device, with no intervening barriers. SYSTEM Mini -Horns The SpectrAlert° Advance series of mini -horn sounders are designed to simplify installations to provide prim iry and secondary signaling for fire and security applications. Features 12 and 24V operation High and low volume settings -Temporal and non - temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini - Alert- sounders Agency Listings u` F MEA LISTED APPROVED approved 54011 3028007 Mt47 -07 -t 7135 - 1653'196 1♦ s The MHR and MHW mini -horns operate at 12 and 24 volts and are idea' ?b: h3c . _, •note! or ,­�sidential fire :;stem,; applications, ,,,heie a smaller notification device is deSired.The rnini -horns offer high and low volume settings, and temporal or non - temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini -horns can operate between 32 and 120 dr grt- Faf ; enh,ei? ,morn a regulated DC or fuii -wave re, [ified, unf,i,e�ed p -wer su,>ply. i hey are iisiei to 0nderavritle :'s Laboratories Standard UL 464 for f:rc prorective signaiing sysrems. SpectrAlert' Advance Mini -Horn Specifications Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini- horn shall be listed tc Under wl itet's •taboratores Starp''a: d UL4txl :or are r, rotc-tive sign. a4nc systen s. Mini -horns shall operate hpro,,crin z' and 120 degrees Fahrenheit from a: reguizted fY: or fl'!-Wave rectified, unt:lmr I he Syric.CircuiI_ MOdu!e,12 Volr r3t::1 w-.; i:icaCion apt ;Lance drone outputs shall operate belwe: n nin and 24 ,,oil m:e:1 circuil outputs shall op rate bervei -n 1 I and 33 volis. ➢�}l.- .f,�kai�,w <rc,�,,;{av: tom•, �5+.v. , .,, , ,., ,.,. Dimensions 4.6" x 2.9 IN x .45t! Weight 2.67 oz. Operating Temperature Range 32 °F to 120 °F (0 °C to 49°6) ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Mounting Surface: single -gang back box Fiush:4 -x 4 -1360 deep hack box i2-: -deep; Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DUFWR or regulated 24DC/FWR Operating Voltage 8 -33 — T - -___ - - - - -" Ooeratina Voltaae with MDL 9 -33 UL Sound Output and Current Draw Data Switch Setting Pattern Ou[out Level 8 -175 VDC 8-175 VFWR Nominal 12 VDC Nornina112 VFWR 16-33 VDC 16-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non - temporal High 72 71 75 74 80 79 4 Non-temporal Low 70 69 73 72 78 77 ,'/{�N,�. �r✓'// x< r!/.1/ /! /�xi✓f/� /'fffis2,y, /�/6 Ise � ��'�,�y� ��� r <z.�+;..«sas��.+. �dec� +hah��bca):aJaa1.'+c1a'+Sava *`' ru-�.c. �. >S\i�c�a`, . •� � >. E. �f..r'i:�a: 8-175 Volts 16-33 Volts _ Switch Position Sound Pattern Volume _- --- ----------------- ----------------------------------------------------------------------------------------------------------------------- DC FWR ---- DC FWR ---- ----- -------- - - ---- ----------------------------------------------------------- 1 Temporal High - ^— 12 — 10 17 15 -- - ^ -T- Temporal Low 2 10 9 14 13 3 Non - temporal High 22 17 29 25 4 Non - temporal Low 17 13 21 19 Ordering Information MHR Mini -Horn, Red MHW Mini -Horn, White s cz I s ensor ��j� oomem TEM�"F 3825 Ohio Avenue • St. Charles, IL 60174 < ;0,' lect[oflange �e�;h(z4nake. ofth6daws:c F.. y;i G', �%R% y`'%� Phone: 800- SFNSOR2 • Fax: 630-377 -6495 0 madaosn� .., o,� /:/i�,J / //r G. nnsa,la- awvm.xna3 'dry; ..... -., :3•Y3 _ TEM �"w�.-S H /fill //• r.ri/ /rf Selectable Output Horns, Strobes, and Horn /Strobes SpectrAlert ®Advance selectable- output horns, strobes, and horn /strobes are rich with features guaranteed to 1 Cu! i!,s(a l atio' i tiines and maximize p!o6ts. The spectrAlert Advance series of notifica :ion appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of Indi, :d.ial devices, a n J 1 1 fi, eId selectable carde'a settings fur B all and ceiling strobes and horn /strobes. vvher; installing AJvarrce pr Ducts, first attach a uni;-ersal counting plate to a four -inch square, four -inch octagon or double -gang junction box. The two -wire mounting plate attaches to a single -gang junction box. Next, connect the no;itica;io.n, appliance circuit 1,virina to the SEM' terminals on the mounting plate. Finally, attach the horn, strobe or horn /strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. he S %eCt ?pert AJ•dlr'.Ce series II:'.. ?UdeS nUtdC;OT fir hits :, ion appliances. Outdoor strobes and horn /strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Features Electrically compatible with existing SpectrAlert products Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela Plug -in design Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 1 15, 135, 150, 177, 185 Same mounting plate for wall- and ceiling -mount units Shorting spring on mounting plate for continuity check before installation •Tamper resistant construction Outdoor wall and ceiling products rated from -40'F to 151'F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products rainproof per Uf_ 50 (NEMA 3R) Compatible with MDI_ sync module Agency Listings _ SI�IALNlG MEA�e 71251653'.186 f,nd.o, nruorsi �� 73W 653 87!wrdr stmbe ' 7115- 1653.188,ho Atruh„, approved \/• m, nrooe: USTO APPROVED 713; -165; 169!homs Chi — S1011 3023572 MEA452 -05 -t 55511 S3593 SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes and horn /strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x V/s -inch back box. A universal mounting plate shall be used for mounting ceiling and wall produc ts.Thr dreuit wiring stall terminate at lh(o univetta? r :r: nlirt , p !ate. 4Jso, Six Yniler? Nivance products, ,,!her, :!t�d with the> Sync-Clrcuit- M'c %;ule accessory, stia ?l be povverevj `:err! a non -coded noO etiar appliance circuit output a., rd shaii operate on a norcriru1 12 or 24 wits. IN' en used 'n ith the Syr!c•C;lCui, Module, l2 =volt ra?ed motif :carior? appliance circuit outpurs stall oN 6re between nine and 1 ZS volts; 2At vcat ra ?e 1 lotifolarior. appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit corn a reguiated 7C, orfull-, ave rectified, ur:fi!tered po,ver supplie Stoaesan i hernistrc tar s ,hall ha +,e fieid seiectable candeh seit ings including 15, 15/75, i0, 75, 95, 1 10, 1 15, 135, 150, 177, 185. Strobe Thr stmoe sl-:a11 be a System Senses Sjf c7A.e..- r.dvarr_< •vl .. e• - __ - - -_ — !ist<^d to UL ­71 and shall e aF,txow^d for fire r otcc ?;ve ervirc•. 1 hsn- crrohe s :all be viredasa r!mar i nlin no ?i cat!ona,:aiancex:( .cxn I 'nitl :tt :eAr,er :cans, ^ ;ithDixa ; :i :iticsActr. lirern- ntsfnrvislblc "sanalin all; Ian.r- s,`!ashint at P 2 sgr' 3 F. pi' ° -=a 9 p 2 1 117, ver the strobe's entire oporating voltage range. The strotx !ight shall •:ansist of :, : <enon flash tube ar>•d assodiated lens/reflectc.r, system. Horn /Strobe Combination I C hnrr; s. robe shalt be a system Sensor SpectrAlert Ax vance Plchiel listed to tJt_ 197 1 ate'? Ut_ 4r;4..rn; st=ab _ pr:xwe., fix pre prn, 'ctive s< :rvicr -. 1l .e horrhtrobe shall be wired as a primary signalir; noti5c ?!or: appliance and c-fnply with rte Americans with Disabilities Act requirements `:,r visible a:lraal!ng appli<:r:ccs, fl:ishinc :it 1 l I:: over the s,r:>t;c= :,entire c,{x:raGn_; voltage rangy :. Tt> r strobe !i;ht shaEl consist of a xenon Flash tt!br-and a s.::iated lensireflec rot sv :ens T to f torn: strait I lave G tree aud?bi6ty optiots ores art opt!•:.n ;., Nc h tetw en a teral,o!ai [}tree patter; arr.1 a norr[err:potal (a !;tit ;u x ) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn /strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and ho"strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahren heir The products shall be listed for use with a System Sensor outdoor /weatherproof back box with half inch and three- fourths inch conduit entries. Synchronization Module The module shall tie a System Sensor S /ric•Circu!t mode; M,11 listed to UL 404 and ;hall be appro'.,ed for fire prGteuive a! vtce. The module shall syridhroniz�- SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn /strobe models over a single pair of wires. The module shall mount to a 4111. x 41V* x 2'/v-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) dreuit,The module shall synchronize multiple zones. Daisy c=haining two or more synchronization modules together will synchronize all the zones they control The module shall not operate on a coded power supply. � "�`�c,r'>'�`•z�� ..: : :• = Ste. : ur, iarz% ziv <�,P.;�a�t���r',is?.s.,w3n�ta�� , , . .. .• .. _.. -.- `•cs .- _ _ . : • : Standard Operating Temperature 32 °F to 120 °F (O °C to 49°C) K Series Operating Temperature -40 °F to 151 °F (-40 °C to 66 °C) Humidity Range 10 to 93% non- condensing (indoor products) -- - -- - •- --•----- -- ------- — -- — - -- - -- - -- ---- ----------- - ----------- -- - - -, -- - — - - - - - -- — -- - - ------ --------------- ------ Strobe Flash Rate 1 'lash pi�r seccxtd Nominal Voltage Regulated 12DC/FWRor regulated 24DC/FWR' Operating Voltage Range' 8 to 173 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG - - --------- -- ----------------------------- ---------- --- --------- -- ---- --------------- -- — -- — - -- -------------- - -- - - -------------------------------------- Ceiling mount dimensions (including lens) 68' d!:acea( :t x ' `;' high (1?3 mores diameter x to mm h!r1h) - - - - -- -- - - - - -- -- - - - - -- - - - ---- Wall mount dimensions (including lens) 5m L > -.7 "W r 2,,D,1­!42 n ar L x 119 mm 1R' x 64 mm D) Horn dimensions 5 -cl. x 4.17-W1 137D (142 n an L x 119 inin'T,r x 33 ntn i to Wall -mount back box skirt dimensions (BBS -2, BBSW -2) - — c)1 x S Jv r 2?T• 1151 min': !- x 128 ir:m ;;t r.b mm: C) Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7.1- (&,meter x 2.25 "high (i 8t) mm dienteter � <- ) 7 mm high) -------------------------------------------------------------------------------------------------------- ---------------------------------------------------------------------- Wall -mount weatherproof back box dimensions (SA -WBB) 5./1 x `�.1 `V x 2.01'' (1 45 corn L x 13) rnrn ; ^/ x 51 rnrn t) -- ----------- ---- ---- -- -------- - - - - -- -- ----------------------------------- Ceiling -mount weatherproof back box dimensions (SA -WBBC) , 7 i - dia:r:cier x 2 0 -hi ,h (180 n :m (1iame'er r 51 mm high) Notes: L ut1'vVave Re: ifie•a "r ",R) volt:3•_r is a -K) rrcq ilatcd, `r i,. varying p :; ver s ;.jfre lhx is us-d ;in s=ane i > % ° :: r supply are :; ;�artcl outputs. 2 P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15//5 cd_ J:5 039S C63 UL Current Draw Data Candela rating at -40T 15 Do not use below 327 15/75 ------------------------------------- 30 75 44 .{�., .�'� \fir A'. 2 70 110 ----- ---- ------ ----- ------ -- -- ------ 115 _ tt 9• 150 :2�.L... , +. ;�S`.�, 177 -- ----- -- ---- --- --- -- ---- - --- 185 8 -175 Volts 16-33 Volts 2 Temporal 8 -175 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard IS' 123 128 66 71 Temporal High 57 S5 69 75 Candela Range 15/75` 142 148 77 81 Temporal Medium 44 49 58 69 30' NA NA 94 96 Temporal Low 38 44 44 48 75` NA NA 158 153 Non - temporal High 57 56 69 75 9S" NA NA 181 176 Non - temporal Medium 42 50 60 69 110 -- --- ------------------------------------------- NA NA --- 202 --- -------------- 195 -- - - -- Non - temporal ------------------------------------ Low - - 41 - 44 SO 50 11S NA NA 210 205 Coded Hi -- High 57 _ -- 55 69 75 _ High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 ------------------------------------------------------------------- NA NA 281 251 185 NA NA 286 258 e� {{����� '4�� iVr, , i � �y'.�.�::. l �Yftf%% i'{{ Yh'. �++ �.�Jnd�. \�^�+\'�ACa?CL:�1S{ +'�M A • Caa . •:•:. a .v ,. .: ... •. t. . . t, ~ . . ? • _ _ _ � •.,v �i��?'�Y�',V �{£•�•f�' •.Y+>. � • � ; 'f%4J�K?.•Y 'fa+�ir�P�� 8 -175 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 — — _ - 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non- temporal Medium ------- - -- --- -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 133 145 75 85 102 163 187 207 216 Non- temporal Low 131 144 68 79 96 156 182 201 210 FWR Input — -- — - - - - - -- Temporal High 136 155 88 97 112 168 190 210 218 hemporal Medium - -- - -- ---------------------------------------------------- 129 152 --- ----- ---- --- --- 78 -- --- -- - - ---- 88 103 -- -- - 160 184 202 206 Tem oral Low - --- - -- ------ 129 151 -- - - -- ------------------------------------------------------------------------------------------- 76 — --------- 86 101 - - - - -- 160 --- - ----------------- 184 ----------------------------------------- 194 201 Non- temporal High 142 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 76-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 24S 259 290 297 Temporal High 215 231 258 265 Temporal Medium ----------------------------------------------------------------------- 235 2.53 -- --- -------------- 288 297 - - - - -- Temporal Medium --- ------------------------------------------------------------------------------------------------- 209 27-4 250 258 Temporal Low - -- 232 251 — 282 -------------------- 292 Temporal Low --------------------- 207 221 248 256 Non- temporal High 255 270 303 309 Non - temporal High --- - - 233 - - -- 248 --------------- 275 281 Non - temporal Medium 242 259 293 299 Non temporal Medium 219 232 262 267 Non - temporal Low 238 254 291 295 Non - temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela% �f/ 9////%/ �f / % %f/f%!/%/%?1f/% %/i//Y /.f!�!?� ' i ratings must be reduced in accordance with this table. . :!/fflf/ffffi�°iffhi:% /flcLc f. /.fffiii ;ff 1A %1SY1. KIY//�vs��,t Y. 24V ItN 1 Listed Candela Candela rating at -40T 15 Do not use below 327 15/75 ------------------------------------- 30 75 44 95 70 110 ----- ---- ------ ----- ------ -- -- ------ 115 110 -- -- ----- ------- ------ - - - - -- -- --- 115 135 135 150 150 177 -- ----- -- ---- --- --- -- ---- - --- 185 177 - --- -- - - - - -- - -- 185 Switch Position Sound Pattern dB 8 -17.5 Volts DC FWR 16-33 Volts _ DC FWR 0 omtna --------- --- --- --- _Reverberant DC FWR - Ane_c_h_oic DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 /4 80 80 86 86 96 96 3 4 Temporal Non - temporal Low High 71 82 73 82 76 88 76 88 83 93 80 92 94 100 89 100 5 Non - temporal Medium 78 78 85 85 90 90 98 —98 6 Non - temporal Low 75 75 81 81 88 84 96 92 7' — — ----------------------------------------------88 8t — Coded Coded High Medium 82 78 82 78 88 85 ------- 85 93 ----------------------------01 90 9 2 90 1 ---------01 97 1 ---- 98 9t Coded Low - 75 75— 81 —81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2 -wire horn /strobe n051395 oc3 Alert Advance Dimensions 7.1" 2.25'1 5.05 =—y �2.23tj Dia. DOaa4 O O 5.98" O O O d e o Q Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information 2 -wire Horn /Strobe, Standard cd, White PC2WH *1 --- ---- -- -- 2 -wire Horn /Strobe, High cd, White Wall Horn /Strobes ------ -- --- ----- P2R *t --- -- -- --- ---- -- - - — -------------------------- 2 -wire Horn /Strobe, Standard cdi, Red P2RH* 2 -wire Horn /Strobe, High cd, Red P2RK* 2 -wire Horn /Strobe, Standard cd, Red, Outdoor P2RHK* - - - 2-wire Horn /Strobe, High cd, Red, Outdoor - - - - -- --- -- ----------------------------------------------------------- P2W* ------------------------- 2 -wire Horn /Strobe, Standard cd, White ---- ------ ---- ------ -- --- ...... - - - - ----------------- P2WH* 2 -wire Horn /Strobe, High cd, White P4R* 4 -wire Horn /Strobe, Standard cd, Red P4RH* 4 -wire Horn /Strobe, High cd, Red P4RK 4 -wire Horn /Strobe, Standard cd, Red, Outdoor P4RHK 4 -wire Horn /Strobe, High cd, Red, Outdoor P4W* - 4 -wire Horn /Strobe, Standard cd, White P4WH* 4 -wire Horn /Strobe, High cd, White Wall Strobes ------------------------------------------------------------------------------------- Back Box Skirt, Wall, Red Back Box Skirt, Wall, White ----------------- - ---------------------------------- ---------------- Back Box Skirt, Ceiling, Red SR *t Strobe, Standard cd, Red _ SRH *1 Strobe, High cd, Red SRK Strobe, Standard cd, Red, Outdoor SRHK -- - ------ ------- ---------------------------------------------- Strobe, High cd, Red,Outdoor --------------------------- ------------- - ----------- SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn /Strobes PC2R* ---------- ---------- - 2 -wire Horn /Strobe, Standard cd, Red - --- ------------ - - - - -- - - - -- - - - -- - - ---- - ------ - - - - - - -- PC2RH* ------------------------------------------------------------------------------------------ 2 -wire Horn /Strobe, High cd, Red PC2RK 2 -wire Horn /Strobe, Standard cd, Red, Outdoor PC2RHK 2 -wire Horn /Strobe, High cd, Red, Outdoor Ceiling-mount ham /strobes 7.1 - Dia. 0 0 5.7' 0 0 � 0 0 Wall weatherproof back box Ceiling weatherproof back box Ceiling Hom /Strobes (contdj PC2W *t 2 -wire Horn /Strobe, Standard cd, White PC2WH *1 --- ---- -- -- 2 -wire Horn /Strobe, High cd, White PC4R 4 -wire Horn /Strobe, Standard cd, Red PC4RH -- - - ------------------------------- PC4RK - ------------------------------------------------------------------------------------- PC4RHK 4 -wire Horn /Strobe, High cd, Red ---- ---- ------ ----- ------- - - --- - ---- - - - - -- --------------------------------- 4 -wire Horn /Strobe, Standard cd, Red, Outdoor 4 -wire Horn /Strobe, High cd, Red, Outdoor PC4W 4 -wire Horn/Strobe, Standard cd, White — — PC4WH 4 -wire Horn /Strobe, High cd, White Ceiling Strobes — -- - - - --------------------------------------------------- SCR' Strobe, Standard cd, Red SCRH* Strobe, High cd, Red SCRK Strobe, Standard cd, Red, Outdoor SCRHK --- - - --- --- ---- SCW*1 Strobe, High cd, Red, Outdoor -- -- -- -- - - - -- - - - -- --------- ------ --- ------ -------- ------ Strobe, Standard cd, White SCWH *t Strobe, High cd, White Hams H-R ------- -------------- HRK — HOm, Red - - - - -- ----- --------------- ---------------------- Horn, Red, Outdoor HW ---- - -- - -- --- - - ---- Horn, White Accessories BBS -2 BBSW -2 - -- -- - - - BBSC -) Back Box Skirt, Wall, Red Back Box Skirt, Wall, White ----------------- - ---------------------------------- ---------------- Back Box Skirt, Ceiling, Red BBSCW -2 Back Box Skirt, Ceiling, White Notes: * Add " -P" to model number for plain housing (no "FIRE "marking on cover), e.g., P2R -P t Add " -SP °to model number for "FU EGO" marking on cover, e.g., P2R -SP t "Standard cd," refers to strobes that include I S, 15/75, 30, 75, 95, 110, and 1 15 candela settings "High cd, "refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in "K° include a weatherproof back box o„ d�• 1 VI- 1J * i c2ax, s se w % � 17, l ���2 3825 Ohio Avenue • St. Charles, IL 60174 • Y/1 '1,13/, ! %%"✓' current VcdW lnt rrt tm,mluJ,N the latest xrsion of thn data sheet. :. r � Phone: 800 SENSOR2 • Fax: 630-377-6495 �:1 Ii / P0510395 -003.12/06• M 7 676 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT MWNOVAO' _T Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ASFR Job Address: 1468 VAIL VALLEY DR VAIL Location.....: Parcel No...: 210109207015 OWNER REVOCABLE TRUST FOR BAHMAN A 11/05/2009 8745 OLD DOMINION DR MCLEAN VA 22102 APPLICANT CLIVER MECHANICAL 11/05/2009 Phone: 970 - 390 -6389 PO BOX 333 EDWARDS CO 81632 License: 435 -M CONTRACTOR CLIVER MECHANICAL 11/05/2009 Phone: 970 - 390 -6389 PO BOX 333 EDWARDS CO 81632 License: 435 -M Desciption: INSTALL BOILER Valuation: $18,000.00 ALL TIMES Permit #: M09 -0250 Project #: PRJ08 -0295 Status ...: ISSUED Applied..: 11/05/2009 Issued. .: 11110/2009 Expires . .: 05/09/2010 Mechanical Permit Fee --- > $360.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $454.00 Plan Check ------------------- > $90.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00 Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $454.00 Total Calculated Fees - -> $454.00 Payments------------ - - - - -> $454.00 BALANCE DUE --------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 11/09/2009 JRM Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. DECLARATIONS mechcanical_permit_041908 I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM -4 PM. /� A Signature of "Owner or Contractor �iL✓ i � li(O C_ c r�,-� Print Name mechcanical_permit_041908 D to TOWN OF VAIL, COLORADOCopy Reprinted on 11 -10 -2009 at 16:14:22 11/10/2009 Statement Statement Number: R090001634 Amount: $454.00 11/10/200904:13 PM Payment Method: Check Init: SAB Notation: JRM ----------------------------------------------------------------------------- Permit No: M09 -0250 Type: MECHANICAL PERMIT Parcel No: 2101- 092 - 0701 -5 Site Address: 1468 VAIL VALLEY DR VAIL Location: Total Fees: $454.00 This Payment: $454.00 Total ALL Pmts: $454.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- MP 00100003111100 MECHANICAL PERMIT FEES 360.00 PF 00100003112300 PLAN CHECK FEES 90.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 Boiler /Furnace Applications MUST include: • Mechanical Room Layout /Plan with Dimensions • Combustion Air Duct Size and Location • Flue or Vent Size • Gas Piping Plan (if applicable) • Heat Loss Calculations* t% • Equipment Cut Sheets for Boiler /Furnace * Not required for same size (BTU) boiler replacement with no system changes, or snow melt Project Street Addreg : [ —o� (Number) (Street) (Suite #) Building /Complex Name: Contractor I Company: f II�G✓' Fireplace Applications MUST include: ❑ Equipment Cut Sheets for Fireplaces /Log Sets (Manufacturer's info showing make, model & approval listing) Office Use: Project #: _I 1�-c U -� 2a 5 Building Permit #: fV/�Jq "�gre-0 Mechanical Permit #: V —02-SO Lot #: n Block &— SubdivisioNAA Uall . Detailed Description of Work: I11sJo bvz'(Q,� Company Address: " l J (use additional sheet if necessary) l City: d State: Cl Zip: ❑ Gas Piping Included (`� Contact Name: G ' , P� 1 L �� � �.'_,� ❑ Gas Piping by Others ❑ Wood to Gas Fireplace Conversion Contact Phone: O �/ (, Boiler Location: E -Mail �) P. / �6 n ro , ". - I \..Z. - Interior ( ) Exterior ( ) Other ( ) Town of Vail Contra c Registrati No.: 373' A Ale Number of Existin Fireplaces: X Gas Appliances Gas Logs Wood /Pellet Contract r Signature (required) Number of Proposed Fireplaces: Property Information Gas Appliances Gas Logs A Wood /Pellet Parcel #: -2 1010 4;.070/ (For parcel #, contact Eagle County Assessors Office at 970 -328 -8640 or ? Type of Building: visit www.eaglecounty.us/patie) Single-Family Duplex( ) Multi-Family ( Commercial( ) Tenant Name: Restaurant( ) Other( ) (Commercial Properties) I �' Date Received: /°! k Owner Name: Complete Valuation for Mechanical Permit: Mechanical $: OO C: \cdev\ forms\ permits \building \mechanical_permit 100109 NOV p 4 2009 rowry of vou, � " 04 -28 -2010 Inspection Request Reporting Page . 4.3 3 _p m Requested Inspect Date: Thursday, April 29, 2010 Inspection Area: JRM Site Address: 1468 VAIL VALLEY DR VAIL A /P /D Information Activity: M09 -0250 Type: B -MECH Sub Type: ASFR Status: ISSUED Const Type: Occupancy: Use: Insp Area: JRM Owner: REVOCABLE TRUST FOR BAHMAN ATEFI Contractor: CLIVER MECHANICAL Phone: 970 - 390 -6389 Description: INSTALL BOILER Requested Inspe Item: Requestor: Comments: Assigned To: Action: Inspection Histo ction s r 39fNDRAG H -Final CLECHANICAL I 33 JM ON Time Exp Requested Time: 09:30 AM Phone: 970 - 390 -6389 Entered By: JMONDRAGON K Item: 200 MECH -Rough ** Approved ** 12/17/09 Inspector: MDENNEY Comment: Item: 310 MECH- Heating Item: 315 PLMB -Gas Piping ** Approved ** 11/13/09 Inspector: BW Comment: Item: 320 MECH- Exhaust Hoods Item: 330 MECH - Supply Air Item: 340 MECH -Misc. Item: 390 MECH -Final pctvtxc (P 1 -711 REPT131 Action: AP APPROVED Action: AP APPROVED Run Id: 11305 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MROFVE Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 PLUMBING PERMIT ASFR Job Address: 1468 VAIL VALLEY DR VAIL Location.....: Parcel No...: 210109207015 OWNER REVOCABLE TRUST FOR BAHMAN A 11/12/2009 8745 OLD DOMINION DR MCLEAN VA 22102 APPLICANT AVON PLUMBING & HEATING 11/12/2009 Phone: 970 - 926 -1608 PO BOX 2051 EDWARDS CO 81632 License: 314 -P CONTRACTOR AVON PLUMBING & HEATING 11/12/2009 Phone: 970 - 926 -1608 PO BOX 2051 EDWARDS CO 81632 License: 314 -P Desciption: COMPLETE PLUMBING FOR REMODEL TO CONVERT TWO- FAMILY DWELLING TO SINGLE - FAMILY DWELLING (GAS PIPING NOT INCLUDED) Valuation: $20,900.00 *..*.......***..*....**..*..*:..:*..*.*...`...... * *. *... * * * **.. *..�. *.... * * * * :+. FEE SUMMARY ** Plumbing Permit Fee --- > $315.00 Will Call ------------------ > $4.00 Plan Check ---------------- > $78.75 Use Tax Fee ------------ > $0.00 Investigation--------- - - - - -> $0.00 Permit #: Project #: Status ... Applied .. Issued. . . Expires . .: P09 -0173 PRJ08 -0295 ISSUED 11/12/2009 11/12/2009 05/11/2010 Total Calculated Fees --- > $397.75 Additional Fees ------------ > $0.00 TOTAL PERMIT FEES - -> $397.75 Total Calculated Fees - -> $397.75 Payments ------------------- > $397.75 BALANCE DUE------ - - - - -> $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 11/12/2009 JLE Action: AP 'i0L`U]It11N] [ 1 17a tePI_ Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSP ION S L BE MADE E_N7-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. / -12-09 Signature of Owner or ntractor Date � (><lei ,y C io12US Print Name plmbpermt1 041908 TOWN OF VAIL, COLORADO Statement Statement Number: R090001649 Amount: $397.75 11/12/200902:30 PM Payment Method:Credit Crd Init: JLE Notation: MARIAN ONDRUS Permit No: P09 -0173 Type: PLUMBING PERMIT Parcel No: 2101 - 092 - 0701 -5 Site Address: 1468 VAIL VALLEY DR VAIL Location: Total Fees: $397.75 This Payment: $397.75 Total ALL Pmts: $397.75 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 78.75 PP 00100003111100 PLUMBING PERMIT FEES 315.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 i PLUMBING PERMIT Project Street Address: I46?5, UtiIL \,1A -A (Number) (Street) Building /Complex Name: Contractor Information: Company: kofd ('I_UM FS, 1I�1�. Company Address: _ "J" Ix77, 'ZO:D � City: t_DAkV\12CY,j (Suite #) State: CD Zip: t6Ga)2 Contact Name: �` (hP t� �raT� rt� ACC WC 7tfE C_Wu/v1__)) Contact Phone: (C y) 1 c (use additional sheet if necessary) E -Mail �e+f 10 �'�) c��lr (;r�U M �Zi ��, M(� Work Class: Town of Vail C actor R istration No.: ��14 // New( ) Addition( Remodel ( ) Repair( ) Other( ) X�(el Type of Building: Contractor Signature (required) Single- Family (V) Duplex ( ) Multi - Family ( ) Commercial Property Information ( ) Restaurant( ) Other( ) Parcel #: ZVD� 07015 Office Use: 11 Project #: P��J Q� O Building Permit #: �lY 1 tJ 60 Plumbing Permit #: Lot #: Block # Subdivision: Detailed Description of Work: C'Ot-) (_ETC✓ 7(_U MZ1N (7Wtl,'1 C _ V CM7 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or Date Received: visit www.eaglecounty.us /patie) Tenant Name: Owner Name: E b`JCA$tt_ (e! jSi 1Oet11�'V�1TG1 -� Complete Valuation for Plumbing Permit-, Plumbing $: nd�s 45,1 AltAlkf O125�(10 E E � V IE D N V 12 2009 TOWN OF VAI 01- Oct -09 F 04 -28 -2010 .o0 .,— Inspection Re .r Reporting Vail �n . city (] Requested Inspect Date: Thursday, April 29, 2010 Inspection Area: JRM Site Address: '1468 VAIL VALLEY DR VAIL age 14 A /P /D Information Activity: P09 -0173 Type: B -PLMB Sub Type: ASFR Status: ISSUED Const Type: Occupancy: Use: Insp Area: JRM Owner: REVOCABLE TRUST FOR BAHMAN ATEFI Contractor: AVON PLUMBING & HEATING Phone: 970 - 926 -1608 Description: COMPLETE PLUMBING FOR REMODEL TO'CONVERT TWO- FAMILY DWELLING TO SINGLE - FAMILY DWELLING (GAS PIPING NOT INCLUDED) Reauested Inspectionts Item,' 290' LP MB -Final Requested Time: 10:30 AM Reque %or: AVON PLUMBING & HEAT Phone: 970 - 926 -1608 or- 970-904- 0091 Com LT'os : 904 -0091 Assig : JMON D Entered By: JMONDRAGON K e -�j Time Exp: REPT131 Run Td: 11305 ;7 � r r Inspection History Item: 220 PLMB -Rou h /D.W.V. 12/17/09 Inspector: ** Approved ** MDENNEY Action: AP APPROVED Comment: Item: 230 PLMB- Rough/Water 12/17/05 Inspector: **A pproved ** MDENNEY Action: AP APPROVED Comment: Item: 240 PLMB -Gas Piping PLMB /Hot Tub Item: Item: 250 -Pool 260 PLMB -Mist. Item: 290 PLMB -Final REPT131 Run Td: 11305 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES TOWNOVIMAJ Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT Permit #: M09 -0258 ASFR Project #: PRJ08 -0295 Job Address: 1468 VAIL VALLEY DR VAIL Location.....: Parcel No...: 210109207015 OWNER REVOCABLE TRUST FOR BAHMAN A 11/17/2009 8745 OLD DOMINION DR MCLEAN VA 22102 APPLICANT WIEMER'S HEATING & SHEETMETA 11/17/2009 Phone: 970 - 328 -9315 PO BOX 22 EAGLE CO 81631 License: 418 -M CONTRACTOR WIEMER'S HEATING & SHEETMETA 11/17/2009 Phone: 970 - 328 -9315 PO BOX 22 EAGLE CO 81631 License: 418 -M Desciption: INSTALL COOLING SYSTEM (BLOWER COIL) Valuation: $9,000.00 Status ...: ISSUED Applied ..: 11/17/2009 Issued . .. 11/17/2009 Expires . .: 05/16/2010 .................< ��...... <...... <�...... * *......<... >..* FEE SUMMARY+....>.>............*....**<.,.»......<. .. <......�......,..... *.,....�, Mechanical Permit Fee --- > $180.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $229.00 Plan Check ------------------- > $45.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00 Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $229.00 Total Calculated Fees - -> $229.00 Payments------------ - - - - -> $229.00 BALANCE DUE --------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 11/17/2009 JLE Action: AP CONDITION OF APPROVAL Cord: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM -4PW, 2 SigMture of Owner or Contractor Date AZ 1", Print Name mechcanical_permit_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R090001665 Amount: $229.00 11/17/200902:15 PM Payment Method: Check Init: SAB Notation: 7576 WIEMER'S HEATING ----------------------------------------------------------------------------- Permit No: M09 -0258 Type: MECHANICAL PERMIT Parcel No: 2101 - 092 - 0701 -5 Site Address: 1468 VAIL VALLEY DR VAIL Location: Total Fees: $229.00 This Payment: $229.00 Total ALL Pmts: $229.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- - ----------------------- - - - - -- ------ - - - - -- MP 00100003111100 MECHANICAL PERMIT FEES 180.00 PF 00100003112300 PLAN CHECK FEES 45.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 MECHANICAL PERMIT Boiler /Furnace Applications MUST include: ❑ Mechanical Room Layout /Plan with Dimensions ❑ Combustion Air Duct Size and Location ❑ Flue or Vent Size ❑ Gas Piping Plan (if applicable) ❑ Heat Loss Calculations* ❑ Equipment Cut Sheets for Boiler /Furnace * Not required for same size (BTU) boiler replacement with no system changes, or snow melt Project Street Address: (Number) (Street) (Suite #) Building /Complex Name: Contractor Information: r ` Company: \0-1'e e- V, S Pc�T, 1\1-k Company Address: City: r__Ola�e_ State: C 0 Zip: I� I Contact Name: r RAVl\dt q r Contact Phone: ` 3 1 b t' i b E -Mail w Town of Vail Contractor Registration No.: X Contractor S gnature fired) Property Information Parcel #: (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecouty.us /patie) Tenant Name: (Commercial Propertie M pr Nam O rn lete Valuation for Mechanical Permit q C) G C) Mechanical $: Fireplace Applications MUST include: ❑ Equipment Cut Sheets for Fireplaces /Log Sets (Manufacturer's info showing make, model & approval listing) Office Use:,n Project #: Building Permit #: 17 I vo Mechanical Permit #:� _ GZ t� Lot #: � Block # � Subdivision:\ /(�(,I 1 Detailed Description f Work: (use additional sheet if necessary) ❑ Gas Piping Included ❑ Gas Piping by Others ❑ Wood to Gas Fireplace Conversion Boiler Location: Interior ( ) Exterior ( ) Other ( ) Number of Existing Fireplaces: Gas Appliances Gas Logs Wood /Pellet Number of Proposed Fireplaces: Gas Appliances Gas Logs Wood /Pellet Type of Building- Single-Family ( Duplex ( ) Multi - Family ( ) Commercial( ) Restaurant ( ) Other ( ) I Date Received: J 2o� __ D CC ►�'( NOV I i 2009 TOWN OF VAI ^1_ .T - - -~ 04 -28 -2010 Inspection Request Reporting Page 12 4.33 Requested Inspect Date: Thursday, April 29, 2010 Inspection Area: JRM Site Address: 1468 VAIL VALLEY DR VAIL A /P /D Information Activity: M09 -0258 Type: B -MECH Const Type: Occupancy: Owner: REVOCABLE TRUST FOR BAHMAN ATEFI Contractor: WIEMER'S HEATING & SHEETMETAL INC Description: INSTALL COOLING SYSTEM (BLOWER COIL) Requested Inspection( Item: 39 MECH -Final / Requestor: WI" R'S I-jEAT -ff " & SHEETMETAL INC Comments: 331 -2424 Assigned To: JMONDRAGON Action: Time Exp: Inspection Histo Sub Type: ASFR Use: Phone: 970 - 328 -9315 Status: ISSUED Insp Area: JRM Requested Time: 10:00 AM Phone: 970 - 328 -9315 Entered By. JMONDRAGON K 'I � f r r �r Item: 200 MECH -Rough ** Approved ** 12/11/09 Inspector: cg Action: CR CORRECTION REQUIRED Comment: 1 PROVIDE MIN. 30" X 30" WORKING PLATFORM AT UNIT IN ATTIC, MIN. 24" WIDE PROVIDE FROM ATTIC ACCES TO PLATFORM REQURIED 2 RELOCATE DUCT IN FRONT UNIT TO MAINTAIN WORKING CLEARANCES OF 30" 4 SEECONDARY CONDIENSOATE NOT P PEDT ONdRAIN CONNECTED TO UNIT 5 UNIT MUST BE SUPPORTED OFF TOP CORD OF TRUSSES, BOTTOM CHORD NOT REPT131 Run Id: 11305 W -01% P L_Lj � VI. VLIIV "Mill CLEARANCE OVER MAYONOT UNIT LOCCATED IN TRUSS N VAULLTED CEILING FRONT HADLLWAY RAFTER SPACE. R -49 ROOF INSULATION IS REQUIRED. DROP DUCT AS NECESSARY RAFTER OUT OF ROOF CAVITY 8 SUPPORT CONDENSATE DRAIN VERTICALLY EVERY 10' PER CODE 9 PROVIDE ATTIC ACCESS LA GE ENOUGH TO REMOVE EQUIPMENT 1 ) FLOAT SWITCH AT BE INSTALLED WITH SHUT -OFF IN DRAIN PAN 12/17/09 Inspector: MDENNEY Action: CR CORRECTION REQUIRED Comment: Items 1, 6 & 9 still remain. 12/21/09 Comment: Inspector: CG Action: CR CORRECTION REQUIRED 1) CONDENSATE DRAIN NOT S40PED TO DRAIN AT FITTINGS NEXT TO EXTERIOR WALL 03/12/10 In ector: JRM Action: AP APPROVED Comment: KATHEN RANGE EXHAUST Item: 340 MECH -Misc. Item: 390 MECH -Final REPT131 Run Id: 11305 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT TOWN *V' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ASFR Job Address: 1468 VAIL VALLEY DR VAIL Location.....: Parcel No...: 210109207015 OWNER REVOCABLE TRUST FOR BAHMAN A 12/14/2009 8745 OLD DOMINION DR MCLEAN VA 22102 APPLICANT RESORT MOUNTAIN ENTERPRISES 12/14/2009 Phone: 970 - 384 -2748 P.O. BOX 2032 GLENWOOD SPRINGS CO 81602 License: 268 -M CONTRACTOR RESORT MOUNTAIN ENTERPRISES 12/14/2009 Phone: 970 - 384 -2748 P.O. BOX 2032 GLENWOOD SPRINGS CO 81602 License: 268 -M Desciption: INSTALL TWO GAS FIREPLACES (GAS PIPING BY OTHERS) Valuation: $4,000.00 ALL TIMES Permit #: M09 -0271 Project #: PRJ08 -0295 Status ...: ISSUED Applied..: 12/14/2009 Issued. .: 12/14/2009 Expires . .: 06/12/2010 .................*...*.<..<. ..... «.. *.. *.......�...` " *.'.., *'FEE SUMMARY....*.........:«.«..:...*....*........ ............................... Mechanical Permit Fee --- > $80.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $104.00 Plan Check ------------------- > $20.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $55.00 Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $159.00 Total Calculated Fees - -> $104.00 Payments------------ - - - - -> $159.00 BALANCE DUE --------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 12/14/2009 JLE Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: CON0011216 SEPARATE PERMIT REQUIRED FOR GAS PIPING BY OTHERS DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. Signature of Owner or Contractor Date Print Name mechcanical_permit_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R090001775 Amount: $159.00 12/14/200904:58 PM Payment Method: Check Init: SAB Notation: 7136- RESORT MOUNTAIN ENT. Permit No: M09 -0271 Type: MECHANICAL PERMIT Parcel No: 2101 - 092 - 0701 -5 Site Address: 1468 VAIL VALLEY DR VAIL Location: Total Fees: $159.00 This Payment: $159.00 Total ALL Pmts: $159.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - --- ------------------------ - - - - -- ------ - - - - -- CL 00100003123000 CONTRACTOR LICENSES 55.00 MP 00100003111100 MECHANICAL PERMIT FEES 80.00 PF 00100003112300 PLAN CHECK FEES 20.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 MECHANICAL PERMIT Boiler /Furnace Applications MUST include: ❑ Mechanical Room Layout /Plan with Dimensions ❑ Combustion Air Duct Size and Location ❑ Flue or Vent Size ❑ Gas Piping Plan (if applicable) ❑ Heat Loss Calculations* ❑ Equipment Cut Sheets for Boiler /Furnace * Not required for same size (BTU) boiler replacement with no system changes, or snow melt Project Street Address: 01 �- (Number) (Street) }� (Suite IV Building /Complex Name: rJC Contractor Information: n Company 75 South Frontage Vaiiii, lorac o , Fireplace Applications MUST include: ❑ Equipment Cut Sheets for Fireplaces /Log Sets (Manufacturer's info showing make, model & approval listing) Office Use: r�o �2°I Project #: Building Permit #: &4_ o Mechanical Permit #: Lot #: 0— Block #,.L Subdivision: V(,j�Y Detailed Description of Work: Company Address: 4 >CL sheet if nece ary) City:C� � S State: zip: ��? ❑ Gas Piping Included Contact Name: _ -rte Gas Piping by Others (F `� ❑ Wood to Gas Fireplac Conversion Contact Phone: q7 E -Mail t� w t i1•� �, �/I��j�s,�} Boiler Location: Interior ( ) Exterior ( ) her ( ) Town of Vail Contr r Registration No.: a: /r► / Number of Existing Fireplaces: X Gas Appliances Gas Logs Wo /Pellet, Co trac or Sign a (` quired)// Number of Proposed Fireplaces: Property Information Gas Appliances )-% Gas Logs Wood /Pellet Parcel #: 2401 0 q Z�, 07 (f 6 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or Type of Building- visit www.eaglecounty.us /patie) Single- Family (7uplex ( ) Multi - Family ( ) Commercial ( ) Tenant Name: (Commercial Properties) Owner Name: Complete Valuation for Mechanical Permit: Mechanical $: Of Restaurant( ) Other( ) Date Received: C: \cdev \forms\ permits\ building \mechanical _permit_100109 I �� THE BELMONT — BLDV400 and BLDV500 The Monessen Belmont Series of direct vent fireplaces provides a louverless, and therefore larger, clearer view of our leading -edge flame technology. W4 54 rcbvich and option Heat with Personality. MONESSEN HEARTH SYSTEMS T BLDV SERIES l • Available in 36" and 42" top vent models • Contemporary, clean face design • Glowing ceramic fiber logs featuring a patented Natural FlameTm aluminized pan burner with random dancing flames and large ember bed • Optional field installed Cottage Clay or Cottage Red firebrick and andirons • Large glass viewing area up to 858 square inches • Thermostatically controlled dual blower available (160 cfm) • Certified as a vented gas fireplace heater to ANS Z21.88 / CSA 2.33 standard • Limited lifetime warranty 11 Aj fircbrxch. FEATURES AND SPECS BLDV FEATURES: • Large viewing area 400: 754 square inches 500: 858 square inches • BTU Ratings (Natural and LP gas) 400: 18,000- 26,000 500: 20,000- 28,000 • Variable Hi -Lo flame adjustment • Standard top vent • 18" flex line with On /Off valve included • Installs with Simpson Dura Vent or Selkirk Metalbestos 4" x 6 -5/8" vent pipe • Includes 15' of pre - installed millivolt wire with wall switch and cover OPTIONAL ACCESSORIES FIELD INSTALLED ACCESSORIES • Decorative Black Mesh Glass Cover (not shown) • Cottage Red or Cottage Clay firebrick • Variable thermostat dual forced air blower BLDV shown as sold FBBLDV(400 1500)CR FBBLDV(400 1500)CC BLOTBLDV Cottage Red Cottage Clay Variable Thermostat Controlled Forced Air Blower (160 cfm) Firebrick Firebrick REMOTE CONTROLS AND WALL THERMOSTATS RCM RCMT RCST On/Off Remote Control On /Off Remote Control with 90 On/Off Thermostat Remote with Receiver min. countdown timer with Control with Receiver. Receiver. TOTAL SYSTEM CONTROL TLM /TLT RCSTEB RCSTTE Touch Light'"' Table Top/Wall OnlOff Thermostat Remote Thermostat ON /OFF Mount TLM On/Off and TLT Control with remote control with 3 -step flame Thermostat Remote 3 -Speed Blower Control, LCD height adjustment and 3 -speed blower Control with Receiver. Display and Receiver control with Receiver. RCTHL Programmable Thermostat Remote Control with Receiver. Y s� WWTD/WWTA Programmable Wireless Wall Thermostat SPECIFICATIONS Product Specifications Model Width Height Depth BTU /H NAT /LP Viewing Area (sq. in.) Circulating Design g Certified Actual Framing Actual Framing Actual Framing 37 1/16" 37 7/16" 40 5/8" 40 7/ — CSA BLDV500 41 1/16" 41 7/16" 40 5/8" 40 7/8" 17 9/16" *17 9/16" 1 20,000- 28,000 1 858 Standard CSA I�C�I f G it Inside Chase Installation * Framing dimension allows for drywall thick MONESSEN HEARTH SYSTEMS 149 Cleveland Drive • Paris, Kentucky 40361 www.monessenhearth.com To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice. © 2007 Monessen Hearth Systems, Inc. �Rn[tiCF 1�- : IIISTfIIlIE ® PBA W W � ��o G MADE IN U.S.A. RDVOCATE HeeNM1, Va�lo6 Berbxue PSSOCIa� ion • gamla BLDV- MHS7707 Corner Installation -*—A ,l Stud Location LATORY APPROVAL -DV series is approved to ANSI Z21.86- 2004/CSA2.32 -2004 and approved tallation in bedrooms and aftermarket manufactured (mobile) homes, not prohibited by state or local codes. Tested to Canadian Standards ation's CSAP.4.1 -02 Testing Method for Measuring Fireplace Efficiency. Warning: • Correct installation of the ceramic fiber logs and periodic cleaning are necessary to avoid potential service problems. • Keep small children and animals away from the hot surfaces at all times. • This appliance must not be connected to a chimney flue servicing a separate solid -fuel burning appliance. • Common venting of this appliance with other gas appliances is not allowed. Sold by: Rev. 06 -07 05 -25 -2010 Inspection Request Re Forting Page 10 4:15 pm Vail, C(LCity 0 Requested Inspect Date: Wednesday, May 26, 2010 Inspection Area: JRM Site Address: 1468 VAIL VALLEY DR VAIL A/P /D Information Activity: M09 -0271 Type: B -MECH Sub Type: ASFR Status: ISSUED Const Type: Occupancy: Use: Insp Area: JRM Owner: REVOCABLE TRUST FOR BARMAN ATEFI Contractor: RESORT MOUNTAIN ENTERPRISES Phone: 970 - 384 -2748 Description: INSTALL TWO GAS FIREPLACES (GAS PIPING BY OTHERS) Requested Inspection(s) Item: 390 MECH -Final Requested Time: 04:00 PM Requestor: RESORT MOUNTAIN ENTERPRISES Phone: 970 - 384 -2748 -or- 970 -384- 2926 Comments: 331 -2424 Assigned To: JMQRAG9N Entered By: JMONDRAGON K Action: Time Exp: Inspection Histo Item: 200 MECH -Rough ** Approved 12/17/09 Inspector: MDENNEY Comment: Item: 310 MECH- Heating Item: 315 PLMB -Gas Piping Item: 320 MECH - Exhaust Hoods Item: 330 MECH - Supply Air Item: 340 MECH -Misc. Item: 390 MECH -Final Action: AP APPROVED REPT131 Run Id: 11428