Loading...
HomeMy WebLinkAboutDRB110021 PlansPROJECT INFORMATION: 2003 I.B.C. & ASSOC. FIRE, MEP VAIL, CO. PROPERTY INFORMATION: BRANDESS BUILDING 12077 NORTH FRONTAGE ROAD VAIL CO 81657 EXISTING BUILDING SOUTHEAST ELEVATION SCOPE OF PROJECT: ANTENNA REPLACEMENT/ NETWORK UPGRADE: THIS PROJECT CONSISTS OF REPLACING (3) EXISTING ANTENNAS WITH (3) NEW ANTENNAS. NEW ANTENNAS & EXPOSED HARDWARE TO BE PAINTED TO MATCH ADJACENT (COLOR) FINISH. MISCELLANEOUS COAX CABLING, GROUNDING & EQUIPMENT MAINTENANCE. CODE ANALYSIS: TENANT FINISH, ACCESSORY U TOWN OF VAIL, CO. SITE tECTIONS TO SITE: OM INVERNESS DRIVE - 70 WEST TO 170 WEST VAIL EXIT 173. STAY 3HT AT THE FORK IN E ROAD. END AT 2077 FRONTAGE RD. W. NORTH Sprint Together with Nextel DATA BUILDING INFORMATION BRANDESS BUILDING -VAIL 12077 NORTH FRONTAGE ROAD VAIL CO 81657 PROJECT DESCRIPTION DN40XC954 BRANDESS BUILDING - VAIL 12077 NORTH FRONTAGE ROAD VAIL CO 81657 ANTENNA MODIFICATION/ NETWORK UPGRADE CONSTRUCTION DRAWINGS BUILDING DATA OCCUPANCY GROUP: B, ACCESSORY U TYPE OF CONSTRUCTION: TYPE V -B, I THIS PROJECT CONSISTS OF REPLACING A (3) EXISTING ANTENNAS, WITH (3) NEW ANTENNAS. MISCELLANEOUS COAX CABLING, GROUNDING & EQUIPMENT MAINTENANCE. ALL NEW ANTENNAS & EXPOSED HARDWARE TO BE PAINTED TO MATCH (COLOR) ADJACENT EXISTING FINISHES. CONTACTS SPRINT /NEXTEL REPRESENTATIVE PROPERTYLANDLORD ARCHITECT BRANDON WHINERY BRIAN O'REILY BRIAN OSTLER CONSTRUCTION MANAGER GMH LTD NEXTEL COMMUNICATIONS 2077 NORTH FRONTAGE RD 123 W BAYAUD AVE 333 INVERNESS DR. SOUTH VAIL CO 80657 DENVER CO, 80223 ENGLEWOOD, COLORADO 80112 CONTACT: VOICE / FAX - (303) 744 -3718 PHONE - (562) 371- 4883 BRIAN O'REILLY FAX - (303) 721 -5379 PHONE: (970) 949 -1636 SPRINT NEXTEL REPRESENTATIVE FAX: (970) 949 -1636 GMH PROJECT MGR JEFF KEITH SCOTT E GILES SITE ACQUISITION GMH LTD SPRINT NEXTEL COMMUNICATIONS 123 W BAYAUD AVE 333 INVERNESS DR. SOUTH T i TO V '� W �-yr 4�1 8 (303) VOICE / FAX 744 -3718 ENGLEWOOD, COLORADO 80112 DESIGN REVIEW PHONE - (303) 564 -7901 FAX - (303) 721 -5379 !i STAFF APPROV - - EEL I n DRAWING INDEX .IAN 28 2011 T1.0 TITLE INFORMATION I PROJECT INFO ,A, N OF VAIL TOWN A1.1 ROOF PLAN / ANTENNA MODIFICATION NOTES Y A1.2 EQUIPMENT PLAN / ANTENNA CONFIGURATION PLAN A3.0 ELEVATIONS ISSUED FOR: APS1.0 PHOTOSIMULATION DESIGN PERMIT APPLICATION OWNER REVIEW 12.3.10 CONSUy -/-,: 1 L STP.IJCTIIRA MECh ANICA_ E! ECTRICAI_ 5TAMP: ARCHITECT: Enn design & archi ecture W RAVA1l�AVF. pENVF1t LOR@13 fAC Y9- >M -YI1R DRA naldsh�r t aleyd i suaAcd r� hcPrgaklurwhdl nmadc�audedalct. to Tk d aid sr ray Sprint Together with Nextel SPRINT / NEXTEL COMMUNICATIONS INC. 333 INVERNESS DRIVE SOUTH ENGLEWOOD CO B0112 PROJECT DN40XC954 BRAN DESS.BLDGNA I L 2077 NORTH FRONTAGE RD VAIL CO 81657 ISSUE DATE: 12.3.10 REVISION SHEET TITLE COVER SHEET NUMBER T1.0 1 OF 1 VICINITY MAP & DIRECTIONS ANTENNA MODIFICATION NOTES: ALPHA SECTOR 1 - EXISTING (1) ANTENNAS NOM. 48" (H) MODEL ANDREW RR65- 18 -04DP @ AZIMUTH 40 DEGREES MECHANICAL DOWNTILT: -2 DEGREES ELECTRICAL DOWNTILT 4 DEGREES BETA SECTOR 2 - EXISTING (1) ANTENNAS NOM. 48" (H) MODEL ANDREW RR65- 18 -04DP @ AZIMUTH 140 DEGREES MECHANICAL DOWNTILT: -2 DEGREES ELECTRICAL DOWNTILT 4 DEGREES TO BE REPLACED WITH: (1) NOM. 57.5" (H) MODEL ANDREW HBX- 4517DS -R2M @ AZIMUTH 40 DEGREES MECHANICAL DOWNTILT: 0 DEGREES ELECTRICAL DOWNTILT: -2 DEGREES TO BE REPLACED WITH: (1) NOM. 57.5" (H) MODEL ANDREW HBX- 4517DS -R2M @ AZIMUTH 140 DEGREES MECHANICAL DOWNTILT: 0 DEGREES ELECTRICAL DOWNTILT: -2 DEGREES ELECTRICAL DOWNTILT: -2 DEGREES I SITE INFO: MODIFICATION INCLUDES INSTALLATION OF RET SYSTEM & ASSOCIATED HARDWARE @ EQUIPMENT LOCATION (E) UTILITY SWITCH BOX (E) RETAINING (E) TRANSFORMER (E) SPRINT / NEXTEL PCS METER, DISCONNECT AND GENERATOR PLUG MOUNTED TO EXTERIOR OF BUILDING —� NEW SPRINT NEXTEL GAMMA SECTOR 3 @ 230 DEGREES (E) SPRINT / NEXTEL /'API c TPAV s (E) BUILDING OVERHANG EDGE 1 A3.0 1 Y Ps1.o 1 ROOF PLAN NORTH A1.1 1/16" = 1' -0" 0 /3GO Type of Structure: Rooftop RAID Center: 30' -0" Latitude = 39.632820N Longitude = - 106.414500W (E) EXTERIOR STAIRS DESIGN REVpl , ST AFF APPR®V CONSULTANT (5): CIVIL: 5TRUCTURAL MECMANICAL ELECTRICAL: STAMP: ARCnITECT design & archi ecture DRAN!ING5: [hr and i a 5=2 d �d h�ldI �� w ProF4 f wfia e a51 tH 'ae'h9c 6 a � The Owner 5hal! be to �n I XW a �nw� P X4 ad a551W rd ra G a�a rp ro `� m m i n ad Sprint � Together with Nextel SPRINT / NEXTEL COMMUNICATIONS INC. 333 INVERNESS DRIVE SOUTH ENGLEWOOD CO 80112 PROJECT DN40XC954 BRANDESS BUILDING 12077 N. FRONTAGE RD VAIL, CO 81657 ISSUE DATE 12.01.10 REVISION DATE SHEET TITLE SITE EXHIBIT SHEET NUMBER A1.1 1 OF 3 AISG NOTES Swapping out all three sector antennas and Orientation change of gamma sector. GAMMA SECTOR 3 - AISG RET cable to be run from first sector from alpha (beta if mercury no TTLNA is on alpha or gamma if no TTLNA is on alpha or beta) that has EXISTING (1) ANTENNAS NOM. NOM. 48" (H) a TTLNA and daisy chained to all other RET antennas. If no TTLNA (Mercury solution) is installed, then install AISG bias T on first sector that RE ANDREW RR65-1 MODEL AND has a RET antenna Rx0 antenna coax and daisy chain other RET antennas from there. If top AISG bias T is needed, install between coax AZIMUTH DEGREES hardline and jumper. MECHANICAL DOWNTILT: 0 DEGREES Install bottom AISG Bias T between bottom of coax hard line and jumper that matches the TTLNA/BIAS T at the top of the coax run. Run RET ELECTRICAL DOWNTILT 4 DEGREES cable from bottom AISG bias T to BTS cabinet. Label RET cable'AISG Cable for antenna adjustment' inside BTS cabinet. Contractor to provide AISG materials list using Sprint APL hardware to Sprint construction manager. This includes model number and quantity TO BE REPLACED WITH: for all RET cables and Bias T's. (1) NOM. 57.5" (H) Contractor to verify AISG functionality by conducting full sweep (0 to full tilt and back again and full azimuth sweeps) and program antenna with MODEL ANDREW HBX- 4517DS -R2M appropriate identifying information. This includes electrical downtilt, Cascade ID, make model and sector information. Once completed, a @ AZIMUTH 230 DEGREES computer screen shot is to be taken for each antenna and emailed to Sprint construction management or RF Engineer for documentation. MECHANICAL DOWNTILT: 0 DEGREES ELECTRICAL DOWNTILT: -2 DEGREES I SITE INFO: MODIFICATION INCLUDES INSTALLATION OF RET SYSTEM & ASSOCIATED HARDWARE @ EQUIPMENT LOCATION (E) UTILITY SWITCH BOX (E) RETAINING (E) TRANSFORMER (E) SPRINT / NEXTEL PCS METER, DISCONNECT AND GENERATOR PLUG MOUNTED TO EXTERIOR OF BUILDING —� NEW SPRINT NEXTEL GAMMA SECTOR 3 @ 230 DEGREES (E) SPRINT / NEXTEL /'API c TPAV s (E) BUILDING OVERHANG EDGE 1 A3.0 1 Y Ps1.o 1 ROOF PLAN NORTH A1.1 1/16" = 1' -0" 0 /3GO Type of Structure: Rooftop RAID Center: 30' -0" Latitude = 39.632820N Longitude = - 106.414500W (E) EXTERIOR STAIRS DESIGN REVpl , ST AFF APPR®V CONSULTANT (5): CIVIL: 5TRUCTURAL MECMANICAL ELECTRICAL: STAMP: ARCnITECT design & archi ecture DRAN!ING5: [hr and i a 5=2 d �d h�ldI �� w ProF4 f wfia e a51 tH 'ae'h9c 6 a � The Owner 5hal! be to �n I XW a �nw� P X4 ad a551W rd ra G a�a rp ro `� m m i n ad Sprint � Together with Nextel SPRINT / NEXTEL COMMUNICATIONS INC. 333 INVERNESS DRIVE SOUTH ENGLEWOOD CO 80112 PROJECT DN40XC954 BRANDESS BUILDING 12077 N. FRONTAGE RD VAIL, CO 81657 ISSUE DATE 12.01.10 REVISION DATE SHEET TITLE SITE EXHIBIT SHEET NUMBER A1.1 1 OF 3 (E) UTILITY SWITCH BOX (E) RETAI (E) TRANSFORMER (E) COAX C/ TRAY (E) SPRINT / NEXTEL PCS METER, DISCONNEC AND GENERATOR PLUG MOUNTED TO EXTERIOR OF BUILDING 1 EQUIPMENT PLAN A1.2 1/4" = 1' -0" UPPER ROOF B: BETA SECTOR 2 (E) SPRINT/ NEXTEL CABL .1 1 o (E) SPRINT / NEXTEL CABLE TRAY ON LOWER ROOF (E) SPRINT/ NEXTEL CABLE TRAY ON UPPER ROOF UPPER ROOF NEW SPRINT NEXTEL GAMMA SECTOR 3 @ 230 DEGREES C: GAMMA SECTOR 3 TrA =I OF VA 3- DESIGN REVS ld GAFF APPROVAL Z 2 ANTENNA CONFIWUkATION P -- 9 \ NORTH NEW SPRINT NEXTEL ALPHA SECTOR 1 @ 40 DEGREES NEW SPRINT NEXTEL BETA SECTOR 2 @ 140 DEGREES PARAPET OF LOWER ROOF BELOW CONSULTANT (5): CIVIL: 5TRUCTURAL: MECHANICAL: ELECTRICAL: STAMP: ARCHITECT. design & archi ecture I— AY -DAir IA- C(IMm FA %YA- ]N -l]Iw C.MHITOa(UMCA�I ^I� DRAWING5: Dew Ord nl dxrncc re��MshTl �yo theProyd(awiuch remadeoarcatedarot. 1� 5Fa1 to MUM , It o I � • � �ma 9a m um Sprint Together with Nextel SPRINT / NEXTEL COMMUNICATIONS INC. 333 INVERNESS DRIVE SOUTH ENGLEWOOD CO 80112 PROJECT DN40XC954 BRANDESS BUILDING 12077 N. FRONTAGE RD VAIL, CO 81657 ISSUE DATE 12.01.10 REVISION DATE SHEET TITLE SITE EXHIBIT SHEET NUMBER A1.2 2OF3 A: ALPHA SECTOR 1 1— KAE�UAKII�Al of W H CD Z LU M U Q GRADE EQUIPMENT INSIDE CLOSET INSIDE BUILDING ON SLAB BUILDING 1 SOUTHEAST ELEVATION A1.2 1/16" = 1' -0" (E) MECHANICAL SCREEN WALL NEW SPRINT NEXTEL NEW SPRINT NEXTEL ALPHA SECTOR 1 GAMMA SECTOR 3 @ 40 DEGREES @ 230 DEGREES (E) SPRINT /NEXTEL (E) VENT STACKS (E) PITCHED GPS ANTENNA ROOFTOP (E) AT &T CABLE 88 LADDER (E) SPRINT /NEXTEL CABLE LADDER (E) EXTERIOR STAIRS EE (E) CONCRETE RETAINING WALL 2 NORTHWEST ELEVATION A1.2 1/16" = V -0" IDE amwe STAFF PPROVAJ- CON5ULTANT T (5): CIVIL: 5TRUCTURAL MECHANICAL ELECTRICAL: 5TAMF: ARCHITECT: design & archi ecture aiwenrnwAVF DFM�FR Ct�RI@ FA %VR)M]TIB WWW. (:MHI11Ja'tY]M('AFT.NfT DRAWING5: Dnm: aM Ikatwns as lffiN mrnts of %w am sh�l miwn'ttc �OQRty of tk wcmGG wi�lha the �CGt kf'A�IiGh tll at!We 5 dEQltf.� a mt TIe;Z5Vh; le Urdto m om Ili rd in Naw. m wntrj D ��aw�g Sprint �I Together with Nextel SPRINT / NEXTEL COMMUNICATIONS INC. 333 INVERNESS DRIVE SOUTH ENGLEWOOD CO 80112 PROJECT DN40XC954 BRANDESS BUILDING 12077 N. FRONTAGE RD VAIL, CO 81657 ISSUE DATE 12.01.10 REVISION DATE SHEET TITLE ELEVATIONS SHEET NUMBER A3.0 3OF3 ANTENNA & MOUNT FINISH NOTES: ALL NEW ANTENNAS & MOUNTS & EXISTING HARDWARE TO BE PAINTED TO MATCH (E) ADJACENT (COLOR) FINISHES- TYPICAL ALL AREAS AREA OF REMODEL- BETA SECTOR 2 CONt,A civi _ 5TRUCTURAL MECHANICAL: ELECTRICAL STAMP: _lrecT_ desi�,n & archi ecture Ih W BAYALp A \E N FACnP 8 YRlN3Jltl WWW- GMNI:ip�\\N<n�lVI i DRA n yy�� sltlY r aI rll UcP%ICdfar Add nmde�awRcdarot. Thc� I� W � , I'd I 6orc�bE X `N Sprint `I Toqether with Nextel SIM OF (3) sOUTH ELEVATION PARTIAL - EXISTING VIEW NTS SIM OF 3 SOU ELEVATION PARTIAL- PROPOSED ` Wolm ::. NTS SPRINT / NEXTEL COMMUNICATIONS INC. 333 INVERNESS DRIVE SOUTH ENGLEWOOD CO 80112 PROJECT DN40XC954 BRANDESS BUILDING 12077 N. FRONTAGE RD VAIL, CO 81657 ISSUE DATE 12.01.10 REVISION DATE SHEET TITLE PHOTOSIM SHEET NUMBER PS 1.0 3OF3