Loading...
HomeMy WebLinkAboutM11-0027NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT M wxOFV Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 4640 MEADOW DR VAIL Location.....: BUILDING 10, UNIT 4 Parcel No...: 210112405004 OWNER HOOKER, STEPHEN P. 02/22/2011 PO BOX 8462 AVON CO 81620 APPLICANT MEADOW MOUNTAIN PLUMBING /HEA 02/22/2011 P.O. BOX 4564 VAIL CO 81658 License: 241 -M CONTRACTOR MEADOW MOUNTAIN PLUMBING /HEA 02/22/201 P.O. BOX 4564 VAIL CO 81658 License: 241 -M Phone: 970-479-2981 Phone: 970-479-2981 Desciption: REMOVE EXISTING HOT WATER BOILER AND GAS FIRED WATER HEATER. REPLACE WITH THE ALLIED SSC -75/40 COMBO HEATING /DOMESTIC HOT WATER HEATER. Valuation: $7,500.00 ALL TIMES Permit #: M11 -0027 Project #: PRJ11 -0045 Status ...: ISSUED Applied..: 02/22/2011 Issued. .: 03/17/2011 Expires . .: 09/13/2011 Mechanical Permit Fee --- > $160.00 Will Call ------------ > $5.00 Total Calculated Fees --- > $205.00 Plan Check ------------------- > $40.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00 Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $205.00 Total Calculated Fees - -> $205.00 Payments ----- — ---------- > $205.00 BALANCE DUE --------- > $0.00 Item: 05100 BUILDING DEPARTMENT 03/08/2011 Martin Action: CR Provide floor plan 03/16/2011 JRM Action: AP APPROVALS Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. �EO LIESTT F0R 10 SHALL BE MA ENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01 M - 4 PM. Signa re of Owner or Contractor Date mechcan ica I_permit_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R110000181 Amount: $205.00 03/17/201109:40 AM Payment Method: Check Init: SAB Notation: 13803 MEADOW MOUNTAIN P &H ----------------------------------------------------------------------------- Permit No: Mll -0027 Type: MECHANICAL PERMIT Parcel No: 2101 -124- 0500 -4 Site Address: 4640 MEADOW DR VAIL Location: BUILDING 10, UNIT 4 Total Fees: $205.00 This Payment: $205.00 Total ALL Pmts: $205.00 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- MP 00100003111100 MECHANICAL PERMIT FEES 160.00 PF 00100003112300 PLAN CHECK FEES 40.00 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIG14ED Project #: _ R, l - o o cff 5 03 Building Permit #: Mechanical Permit #: MI l - a, 7 n ,� Taw�vINK 970- 479 -2149 (Inspections) TOWN OF VAIL MECHANICAL PERMIT APPLICATION 75 S. Frontage Rd. Permit will not be accepted without the following: Vail, Colorado 81657 Provide Mechanical Room Layout drawn to scale to include: 5 0 ❑ Mechanical Room Dimensions r �` u ❑ Combustion Air Duct Size and Location Cl a Flue, Vent and Gas Line Size and Location ❑ Heat Loss Calcs FEB 2 0 2011 ❑ Equipment Cut /Spec Sheets CONTRACTOR INFORMATION Tn v I Mechanical Contractor Town of Vail Reg. No.: Contact and Phone s: Meadow N D �� ► 9,1 y 1 E -Mail Address: Cn 14 r Contractor Signature.:, %.%JFWLC I c VALUA iUn VUK MtCHANICAL PERMIT (Labor & Materials) MECHANICAL: $ -7 , rJ' O C) °O ContactEaa /e Cnunty A c caccnrc mF 07n 770_0cnn „ _rte I Parcel # alDl O U Job Name: Y�r'L L0.LA41 CN_ J t t J ni-4- Legal Description Lot: Owners Name: ry.1A*sy0 .� Block: Filing: Subdivision: Addr sS Engineer: Address: Phone: Detailed description of work Work Class: New () Addition ( ) Alteration ( ) Repair ( ) Other ( ) Boiler Location: Interior ( ) Exterior ( ) Other ( ) [' Does an EHU exist at this location: Yes ( ) No F) Type of Bldg: Single family ( ) Duplex ( ) Multi family ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building: i No. of Accommodation Units in this building: No/Type of Fireplaces Existing: Gas A liances Gas Los Wood /Pellet Wood Burnin No/Type of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood /Pellet ( ) Wood Burning (NOT ALLOWED) Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No( ) I * * ** * * * * * * * * * * * * * * * * ** *FOR OFFICE USE ONLY * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Other Fees: Planner Sign-off: Acce ted By: DRB Fees: I Date Received: 1'n O f� PO V 7 A24 \ \Vail\ data\ cdev \FORMS\PERMITS \MECHPERM.DOC 07/26/2002 adow ountain Plumbing & Heating Service INC --.o P.O. Box 4564 a Vail, CO 81658 (970)479 -2981 or (970)845-0774 Fax (970)479 -5161 February 28, 2011 To Town Of Vail Community Development 75 South Frontage Road Vail Colorado 81657 970 - 479 -2138 / Attention: David Rhoades ' RE: Vail Racquet Club Building 10 Unit 21 Good afternoon David, I am contracted with Kirk Lautensleger, He is a home owner at the Vail Racquet club. His heat boiler failed at his home and is not repairable, Replacement is the only option. His unit is located on the lowest level of building 10. I realize the requirements for the Town Of Vail is that all equipment being changed out needs to be high efficiency. The current vent system is B vent or double wall construction. All new high efficiency equipment needs PVC, CPVC or stainless piping installed. In order to change out the old vent pipe it would require major demo of the two units above Mr. Lautenslagers. I am asking for permission to install equipment that could utilize the existing B vent and not cause major disruption to the other homeowners units and speed up the installation process for Mr. Lautensleger. Thanks for your consideration. Sincerely, Fred Espinoza (Owner MMPH) Town of Vail Mechanical Codes and Design Criteria You must obtain Design Review Board (DRB) approval if any of the mechanical work will involve ANY exterior work. This includes and is not limited to removal and replacement of driveway snow melt systems. Please contact a planner at 479 -2128 before submitting your mechanical permit application. The Town of Vail has adopted the 1998 International Mechanical Code (IMC) with the 1997 Uniform Mechanical Code (UMC) as an acceptable alternative. All new construction within the Town of Vail is considered to be of unusually tight construction, thus all combustion air is required to be drawn from outside the structure for mechanical equipment. Reference the 1997 UMC Sec. 701.2. Town of Vail Fireplace Ordinance In September of 1991, the Vail Town Council adopted an ordinance which restricts to construction and use of open hearth fireplaces within municipal boundaries. Since that time the ordinance has undergone numerous changes and revisions, striving for compromise, yet effectiveness in addressing the air quality issue. Therefore the following criteria has been adopted: Construction of open hearth wood burning fireplaces is no longer permitted within Town of Vail municipal boundaries. Dwelling Units — Each new dwelling unit may contain: One (1) EPA Phase II certified solid fuel burning device and no more than two (2) gas appliances (B vent) OR Two (2) gas log fireplaces and no more than two (2) gas appliance fireplaces (B bent). Restricted Dwelling Units — Each new restricted dwelling unit may contain: One (1) gas log fireplace and not more than one (1) gas appliance fireplace. Accommodation Units — Each new accommodation unit may contain: One (1) gas log fireplace or one (1) gas appliance fireplace. If two or more separate dwelling units or accommodation units are combined to form one larger unit, the combined unit may retain one woodburning fireplace (if one already exists) and no more than 2 gas appliance fireplaces, or may convert up to two existing fireplaces to gas. If during the course of a remodel an existing woodburning fireplace is altered or moved, the unit must then comply with all provisions of the ordinance. That is, the fireplace must be converted to natural gas or replaced by an EPA Phase II certified unit. F: /everyone / forms/ mechperm Hydi - oilic Heating Your best choice for In -Floor Radiant and Domestic Hot Water Heating. Heats Your Home Efficient) Uses a powerful Mini -Gas® hot water (hydronic) boiler, CGA rated at 84.6% efficiency. Provides an Abundant Source of Domestic Hot Water The stainless steel heat exchanger generates up to fives times the amount of hot water compared to a direct -fired water heater. Attractive Compact Design A small 24 x 24 footprint saves valuable floor space. Ideal for closet installations. Eliminates Extra Venting Delivers higher efficiency compared to a conventional system with a separate water heater and hot water boiler. E -Z Handling and Installation The boiler and tank are shipped separately in two light- weight packages, making the Space - Saver Combo easy to handle on the job site. The pre -wired boiler installs quickly on top of the tank and features a zone control board for easy electrical hookup. Warranty Protection The Space -Saver Combo is manufactured to the highest standards, employing only top quality materials and workmanship. The proven design delivers a 10 year warranty on the heating boiler and stainless steel heat exchanger (see complete warranty for details). Allied Engineering Company 94 Riverside Drive, North Vancouver, BC, V7N 2M6 Tel. 604 - 929 -1214 Fax: 604 - 929 -5184 CH-1��f o�z ME 'moo. 1-12_ 0 I , B 91/2 18 1/2 36 B t/8 � 12— Max. IstHr. Performance Standard Input A* B* C* D* 65 °F Rise Models ** BTUs (Gallons) 'Dimensions in inches. Clearances: Sides 2 ", Front 6 ", Back 2'. ' Additional clearances required for piping. ** Custom sizes also available. SSC 50/40 50 6.25 74.0 4.0 11.5 115 SSC 75/40 75 6.25 74.8 5.0 14.5 153 SSC 100/40 100 6.25 74.8 5.0 17.5 191 SSC 125/40 125 7.00 76.8 6.0 20.5 229 SSC 150/40 150 Solid Warranty Protection - Backed by 45 years of customer service Special features: Exclusive Zone Control Board Extensive Mini -Gas° Boiler Package Custom Pump Adapter High Grade Stainless Steel Burners Durable Baked Enamel Case Convenient Component Construction Boiler &Water Tank can be handled separately for ease of shipping and installation. Mini - Gas° Boiler • Natural gas or propane • 84.6% Energy efficient (CGA steady state) •Optional automatic vent damper • Optional electronic ignition Efficiency Plus Water Heater • Extra Long -life Stainless Steel Tank •Large capacity 40 US gallon tank •High Recovery Rates Call for the detailed technical specifications that apply to your project. Allied En g ineerin g Com p an y � 94 Riverside Drive, North Vancouver, BC, V7H 2M6 Tel. 604 - 929 -1214 Fax: 604 - 929 -5184 7.00 76.8 6.0 23.5 268 Solid Warranty Protection - Backed by 45 years of customer service Special features: Exclusive Zone Control Board Extensive Mini -Gas° Boiler Package Custom Pump Adapter High Grade Stainless Steel Burners Durable Baked Enamel Case Convenient Component Construction Boiler &Water Tank can be handled separately for ease of shipping and installation. Mini - Gas° Boiler • Natural gas or propane • 84.6% Energy efficient (CGA steady state) •Optional automatic vent damper • Optional electronic ignition Efficiency Plus Water Heater • Extra Long -life Stainless Steel Tank •Large capacity 40 US gallon tank •High Recovery Rates Call for the detailed technical specifications that apply to your project. Allied En g ineerin g Com p an y � 94 Riverside Drive, North Vancouver, BC, V7H 2M6 Tel. 604 - 929 -1214 Fax: 604 - 929 -5184 �y1 s 8 7 C >e C O L u O