HomeMy WebLinkAboutM11-0027NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT
M wxOFV
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
MECHANICAL PERMIT
AMF
Job Address: 4640 MEADOW DR VAIL
Location.....: BUILDING 10, UNIT 4
Parcel No...: 210112405004
OWNER HOOKER, STEPHEN P. 02/22/2011
PO BOX 8462
AVON
CO 81620
APPLICANT MEADOW MOUNTAIN PLUMBING /HEA 02/22/2011
P.O. BOX 4564
VAIL
CO 81658
License: 241 -M
CONTRACTOR MEADOW MOUNTAIN PLUMBING /HEA 02/22/201
P.O. BOX 4564
VAIL
CO 81658
License: 241 -M
Phone: 970-479-2981
Phone: 970-479-2981
Desciption: REMOVE EXISTING HOT WATER BOILER AND GAS FIRED WATER
HEATER. REPLACE WITH THE ALLIED SSC -75/40 COMBO
HEATING /DOMESTIC HOT WATER HEATER.
Valuation: $7,500.00
ALL TIMES
Permit #: M11 -0027
Project #: PRJ11 -0045
Status ...:
ISSUED
Applied..:
02/22/2011
Issued. .:
03/17/2011
Expires . .:
09/13/2011
Mechanical Permit Fee --- > $160.00 Will Call ------------ > $5.00 Total Calculated Fees --- > $205.00
Plan Check ------------------- > $40.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00
Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $205.00
Total Calculated Fees - -> $205.00 Payments ----- — ---------- > $205.00
BALANCE DUE --------- > $0.00
Item: 05100 BUILDING DEPARTMENT
03/08/2011 Martin Action: CR Provide floor plan
03/16/2011 JRM Action: AP
APPROVALS
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
�EO LIESTT F0R 10 SHALL BE MA ENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01
M - 4 PM.
Signa re of Owner or Contractor Date
mechcan ica I_permit_041908
TOWN OF VAIL, COLORADO Statement
Statement Number: R110000181 Amount: $205.00 03/17/201109:40 AM
Payment Method: Check Init: SAB
Notation: 13803 MEADOW
MOUNTAIN P &H
-----------------------------------------------------------------------------
Permit No: Mll -0027 Type: MECHANICAL PERMIT
Parcel No: 2101 -124- 0500 -4
Site Address: 4640 MEADOW DR VAIL
Location: BUILDING 10, UNIT 4
Total Fees: $205.00
This Payment: $205.00 Total ALL Pmts: $205.00
Balance: $0.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
MP 00100003111100 MECHANICAL PERMIT FEES 160.00
PF 00100003112300 PLAN CHECK FEES 40.00
WC 00100003112800 WILL CALL INSPECTION FEE 5.00
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIG14ED
Project #: _ R, l - o o cff 5
03 Building Permit #:
Mechanical Permit #: MI l - a, 7
n
,�
Taw�vINK 970- 479 -2149 (Inspections)
TOWN OF VAIL MECHANICAL PERMIT APPLICATION
75 S. Frontage Rd. Permit will not be accepted without the following:
Vail, Colorado 81657
Provide Mechanical Room Layout drawn to scale to include:
5 0 ❑ Mechanical Room Dimensions r �`
u ❑ Combustion Air Duct Size and Location
Cl
a Flue, Vent and Gas Line Size and Location
❑ Heat Loss Calcs FEB 2 0 2011
❑ Equipment Cut /Spec Sheets
CONTRACTOR INFORMATION Tn v I
Mechanical Contractor Town of Vail Reg. No.: Contact and Phone s:
Meadow N D �� ► 9,1 y 1
E -Mail Address: Cn 14
r
Contractor Signature.:,
%.%JFWLC I c VALUA iUn VUK MtCHANICAL PERMIT (Labor & Materials)
MECHANICAL: $ -7 , rJ' O C) °O
ContactEaa /e Cnunty A c caccnrc mF 07n 770_0cnn „ _rte I
Parcel # alDl O U
Job Name: Y�r'L L0.LA41 CN_
J t t
J ni-4-
Legal Description Lot:
Owners Name: ry.1A*sy0 .�
Block: Filing: Subdivision:
Addr sS
Engineer:
Address:
Phone:
Detailed description of work
Work Class: New () Addition ( ) Alteration ( ) Repair ( ) Other ( )
Boiler Location: Interior ( ) Exterior ( ) Other ( )
[' Does an EHU exist at this location: Yes ( ) No F)
Type of Bldg: Single family ( ) Duplex ( ) Multi family ( ) Commercial ( ) Restaurant ( ) Other ( )
No. of Existing Dwelling Units in this building:
i No. of Accommodation Units in this building:
No/Type of Fireplaces Existing: Gas A liances Gas Los Wood /Pellet Wood Burnin
No/Type of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood /Pellet ( ) Wood Burning (NOT ALLOWED)
Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No( )
I * * ** * * * * * * * * * * * * * * * * ** *FOR OFFICE USE ONLY * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Other Fees: Planner Sign-off: Acce ted By:
DRB Fees: I Date Received:
1'n
O
f�
PO
V
7
A24
\ \Vail\ data\ cdev \FORMS\PERMITS \MECHPERM.DOC 07/26/2002
adow
ountain
Plumbing & Heating
Service INC --.o
P.O. Box 4564 a Vail, CO 81658
(970)479 -2981 or (970)845-0774
Fax (970)479 -5161
February 28, 2011
To Town Of Vail Community Development
75 South Frontage Road
Vail Colorado 81657
970 - 479 -2138 /
Attention: David Rhoades '
RE: Vail Racquet Club Building 10 Unit 21
Good afternoon David,
I am contracted with Kirk Lautensleger, He is a home owner at the Vail
Racquet club. His heat boiler failed at his home and is not repairable,
Replacement is the only option.
His unit is located on the lowest level of building 10. I realize the
requirements for the Town Of Vail is that all equipment being changed out
needs to be high efficiency. The current vent system is B vent or double wall
construction. All new high efficiency equipment needs PVC, CPVC or
stainless piping installed. In order to change out the old vent pipe it would
require major demo of the two units above Mr. Lautenslagers.
I am asking for permission to install equipment that could utilize the
existing B vent and not cause major disruption to the other homeowners
units and speed up the installation process for Mr. Lautensleger.
Thanks for your consideration.
Sincerely,
Fred Espinoza
(Owner MMPH)
Town of Vail Mechanical Codes and Design Criteria
You must obtain Design Review Board (DRB) approval if any of the mechanical work will involve
ANY exterior work. This includes and is not limited to removal and replacement of driveway snow
melt systems. Please contact a planner at 479 -2128 before submitting your mechanical permit
application.
The Town of Vail has adopted the 1998 International Mechanical Code (IMC) with the 1997 Uniform
Mechanical Code (UMC) as an acceptable alternative.
All new construction within the Town of Vail is considered to be of unusually tight construction, thus
all combustion air is required to be drawn from outside the structure for mechanical equipment.
Reference the 1997 UMC Sec. 701.2.
Town of Vail Fireplace Ordinance
In September of 1991, the Vail Town Council adopted an ordinance which restricts to construction and
use of open hearth fireplaces within municipal boundaries. Since that time the ordinance has
undergone numerous changes and revisions, striving for compromise, yet effectiveness in addressing
the air quality issue. Therefore the following criteria has been adopted:
Construction of open hearth wood burning fireplaces is no longer permitted within Town of Vail
municipal boundaries.
Dwelling Units — Each new dwelling unit may contain:
One (1) EPA Phase II certified solid fuel burning device and no more than two (2) gas appliances
(B vent)
OR
Two (2) gas log fireplaces and no more than two (2) gas appliance fireplaces (B bent).
Restricted Dwelling Units — Each new restricted dwelling unit may contain:
One (1) gas log fireplace and not more than one (1) gas appliance fireplace.
Accommodation Units — Each new accommodation unit may contain:
One (1) gas log fireplace or one (1) gas appliance fireplace.
If two or more separate dwelling units or accommodation units are combined to form one larger
unit, the combined unit may retain one woodburning fireplace (if one already exists) and no more
than 2 gas appliance fireplaces, or may convert up to two existing fireplaces to gas.
If during the course of a remodel an existing woodburning fireplace is altered or moved, the unit
must then comply with all provisions of the ordinance. That is, the fireplace must be converted to
natural gas or replaced by an EPA Phase II certified unit.
F: /everyone / forms/ mechperm
Hydi - oilic
Heating
Your best choice for In -Floor Radiant
and Domestic Hot Water Heating.
Heats Your Home Efficient)
Uses a powerful Mini -Gas® hot water
(hydronic) boiler, CGA rated at 84.6%
efficiency.
Provides an Abundant Source of
Domestic Hot Water
The stainless steel heat exchanger
generates up to fives times the amount
of hot water compared to a direct -fired
water heater.
Attractive Compact Design
A small 24 x 24 footprint saves
valuable floor space. Ideal for closet
installations.
Eliminates Extra Venting
Delivers higher efficiency compared to
a conventional system with a separate
water heater and hot water boiler.
E -Z Handling and Installation
The boiler and tank are shipped separately in
two light- weight packages, making the Space -
Saver Combo easy to handle on the job site. The
pre -wired boiler installs quickly on top of the
tank and features a zone control board for easy
electrical hookup.
Warranty Protection
The Space -Saver Combo is manufactured to the
highest standards, employing only top quality
materials and workmanship. The proven design
delivers a 10 year warranty on the heating boiler
and stainless steel heat exchanger (see complete
warranty for details).
Allied Engineering Company
94 Riverside Drive, North Vancouver, BC, V7N 2M6 Tel. 604 - 929 -1214 Fax: 604 - 929 -5184
CH-1��f o�z
ME
'moo.
1-12_
0
I ,
B
91/2
18 1/2 36
B t/8
� 12— Max. IstHr.
Performance
Standard Input A* B* C* D* 65 °F Rise
Models ** BTUs (Gallons)
'Dimensions in inches. Clearances: Sides 2 ", Front 6 ", Back 2'.
' Additional clearances required for piping. ** Custom sizes also available.
SSC 50/40 50 6.25 74.0 4.0 11.5 115
SSC 75/40 75 6.25 74.8 5.0 14.5 153
SSC 100/40 100 6.25 74.8 5.0 17.5 191
SSC 125/40 125 7.00 76.8 6.0 20.5 229
SSC 150/40 150
Solid Warranty Protection -
Backed by 45 years of customer service
Special features:
Exclusive Zone Control Board
Extensive Mini -Gas° Boiler Package
Custom Pump Adapter
High Grade Stainless Steel Burners
Durable Baked Enamel Case
Convenient Component Construction
Boiler &Water Tank can be handled
separately for ease of shipping and
installation.
Mini - Gas° Boiler
• Natural gas or propane
• 84.6% Energy efficient (CGA steady state)
•Optional automatic vent damper
• Optional electronic ignition
Efficiency Plus Water Heater
• Extra Long -life Stainless Steel Tank
•Large capacity 40 US gallon tank
•High Recovery Rates
Call for the detailed technical specifications that apply to your project.
Allied En g ineerin g Com p an y
�
94 Riverside Drive, North Vancouver, BC, V7H 2M6 Tel. 604 - 929 -1214 Fax: 604 - 929 -5184
7.00
76.8
6.0
23.5
268
Solid Warranty Protection -
Backed by 45 years of customer service
Special features:
Exclusive Zone Control Board
Extensive Mini -Gas° Boiler Package
Custom Pump Adapter
High Grade Stainless Steel Burners
Durable Baked Enamel Case
Convenient Component Construction
Boiler &Water Tank can be handled
separately for ease of shipping and
installation.
Mini - Gas° Boiler
• Natural gas or propane
• 84.6% Energy efficient (CGA steady state)
•Optional automatic vent damper
• Optional electronic ignition
Efficiency Plus Water Heater
• Extra Long -life Stainless Steel Tank
•Large capacity 40 US gallon tank
•High Recovery Rates
Call for the detailed technical specifications that apply to your project.
Allied En g ineerin g Com p an y
�
94 Riverside Drive, North Vancouver, BC, V7H 2M6 Tel. 604 - 929 -1214 Fax: 604 - 929 -5184
�y1