HomeMy WebLinkAboutE10-0279 PlansELECTRICAL LEGEND (NOT ALL SYMBOLS REQUIRED FOR THiS PROJECT) Q RECESSED OR SURFACE DOWNLIGHT CH WALL MOUNTED LIGHT FIXTURE t_.D RECESSED FLUOR. LIGHT FIXTURE O SURFACE FLUOR. LIGHT FIXTURE - AUTHORITY HAVING JURISDICTION FIXTURE DESIGNATIONS: •ALUMINUM UPPER CASE - FIXTURE TYPE - COPPER LOWER CASE - SWITCH DESIGNATION - ELECTRICAL CONTRACTOR SHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUP t-- ---� FLUORESCENT STRIP FIXTURE -( TRACK LIGHT AS NOTED OR SCHEDULED - ELECTRIC WATER COOLER WALL WASHER �-•-� POLE- MOUNTED FIXTURE - GROUND POST (BOLLARD) FIXTURE t=Za STEP LIGHT - MECHANICAL CONTRACTOR CEILING OR WALL MOUNTED EXIT LIGHT - NOT IN CONTRACT EMERGENCY BATTERY LIGHTS -NIGHT LIGHT DUPLEX RECEPTACLE C it UNLESS NOTED - NOT TO SCALE DOUBLE DUPLEX RECEPTACLE 0111 UNLESS NOTED i� FLUSH FLOOR DUPLEX RECEPTACLE + ? SPECIAL OUTLETAS NOTED - UNDERGROUND DUPLEX RECEPTACLE HALF-SWITCHED 0 1W UNLESS NOTED 0 POP -UP RECEPTACLE - WEATHERPROOF TELE-POWER POLE -�- { MULTI-OUTLET PLUG STRIP p•; 0 ID Qi JUNCTION BOX IN FLOOR, CEILING OR IN WALL OF DEVICE AFF ORAFG COMPUTERRELEPHONE OUTLET IN FLOOR OR WALL �-• TELEVISION OUTLET U TELEPHONE BACKBOARD Q CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING —l► CIRCUIT HOMERUN — —• — CONDUIT RUN BELOW FLOOR OR GRADE ] CONDUIT STUBUP - CAP &MARK !1 LIGHT SWITCH AT 46" UNLESS NOTED *P SUBSCRIPTS: i 2 = 2 -POLE SWITCH [] tHr 3 = 3-WAY SWITCH �} 4 = 4 -WAY SWITCH M = MOTION- OPERATED SWITCH K = KEY - OPERATED SNATCH TO = THERMAL OVERLOAD SWITCH `1 P - SWITCH WITH PILOT LIGHT ® DIMMER SWITCH w7 WATTAGE (� PUSHBUTTON CONTROL STATION WRUS10N MOTION DETECTOR AS SPECIFIED, CORRIDOMOOM PHOTOELECTRIC CELL TIME SWITCH KEY - OPERATED ACCESS SWITCH THERMOSTAT AT 60" UNLESS NOTED SURVEILLANCE CAMERA DIVISION 15 EQUIPMENT �— FOOD SERVICE EQUIPMENT COMMUNICATION SYSTEM �S @I SPEAKER IN CELING OR WALL V[}# VOLUME CONTROL AT 60" UNLESS NOTED <8> o-_ MICROPHONE OUTLET IN FLOOR BOX OR WALL TRANSFORMER CALL -IN SWITCH ''... © PROGRAM BELL p INTERCOM (9 CLOCK ® AMPLIFIER • a • a 1 SCOPE: Furnish all materials and labor required to execute this work as indicated on drawing and as specified, as necessary to complete the contract Electrical work shall include, but not limited to, these major items: A. Complete wiring system for new fighting and power as shown, including new panelboards, new conduits, new wires, new wiring devices, new control devices, etc. for a complete lighting and and power system. a. Complete feeder(s) installation as required for new and/or electrical apparatus as shown on single line diagram and drawings. b. Complete branch circuit wiring required for the connection of emergency fighting and exit signs to existing emergency stand by power system. 2. Complete provision, installation and connection of fighting fixtures, exit signs and lamps as specified and as shown on drawings. 3. Fire alarm system will be by electrical contractor. 4. Complete connection of HVAC /Plumbing motor(s), water heater(s), equipment, etc. furnish by mechanical - refer to both electrical and and mechanical drawing for scope and work and additinai infor- mation. 5. Provide grounding and bonding Facilities. 6. Complete all electrical demolition as required. 7. Core drilling and patching of existing building structure required for electrical work. Core drilling shall follow Building Standard procedures and contractor shall have written approvals from building owner prior to start of any work. 8. Test of entire system and work 9. Operating, Maintenance and identification instructions manuals, if any. 10. PERMITS AND FEES: Obtain and pay for all necessary permits, inspeo- tlons, examinations and fees or charges necessary for execution and completion of electrical work. 11. REGULATIONS AND CODES: A. Applicable codes: National Electric Code (2008) Conform to the prevailing edition and amendments thereto of the Town of Vail Electrical Code, pertinent NFPA publications and to the requirements of Federal, State or other City agencies having jurisdiction. 12. SHOP DRAWINGS AND SUBMITTAL: A. Contractor shall submit shop drawings for engineer review and approval. B. Shop drawing submittal shall include: 1. Lighting fixtures. 13. CONDUIT AND WtRE: A. CONDUCTOR SIZES AND TYPES: Use only copper wire, 600 volt insulation, stranded in sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14, stranded. In sizes #1 and smaller, use types TW, THHN or THAI. In sizes larger than #1, use THW or XHHW. Use type THHN for Wires entering or passing through fluorescent righting fixtures. B. MC cable permitted per local codes. 14. ELECTRICAL DEVICES A. Convenience receptacles will be 20 amp, commercial grade decora style. Finish per owner or architect B. Light switches will be 20 amp, commercial grade, decora style. Finish per owner or architect C. Dimming switches Will be a minimum of 604w or as noted. Provide decora style, finish per owner or architect D. All mounting heights will conform to ADA guidelines. Typical receptacle heights will be +18 "AFF and switch heights will be +46 "AFF unless noted otherwise. E. Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc. as required by code. 15. SUPPORT A. Support all electrical equipment independent of accessible ceilings as required by NEC. 16. ELECTRICAL BOXES A. At fire rated wall space electrical boxes at opposite sides of the wall no less than 24" horizontal distance. B. When phone, TV & power receptacles are shown on plan next to each other. Locate respective receptacles next to each other on site with no more than 1" seperating cover plates. ABBREVIATIONS AC -ABOVE COUNTER AFF -ABOVE FINISHED FLOOR AFG • ABOVE FINISHED GRADE AHJ - AUTHORITY HAVING JURISDICTION AL •ALUMINUM CU - COPPER EC - ELECTRICAL CONTRACTOR EM - EMERGENCY EMP - ENERGY MANAGEMENT PANEL EWC - ELECTRIC WATER COOLER GC - GENERA. CONTRACTOR GNO - GROUND GFI - GROUND FAULT INTERRUPTER MG - MECHANICAL CONTRACTOR NIC - NOT IN CONTRACT NL -NIGHT LIGHT NTS - NOT TO SCALE PC - PLUMBING CONTRACTOR REF - REFERENCE UG - UNDERGROUND UTP UNSHIELDED TWISTED PAIR WP - WEATHERPROOF XFMR - TRANSFORMER +18" - MOUNTING HEIGHT TO CENTERLINE • OF DEVICE AFF ORAFG FIRE ALARM SYSTEM ."FRCP FIRE ALARM CONTROLPANEL U FIRE ALARM ANNUNCIATOR PANEL Q FIRE ALARM PULLSTATION s! • • ALARM HORN OR SPEAKER []O= COMBINATION HORMSTROBE OR SPEAKER(STROBE OH THERMAL HEAT DETECTOR !1 SMOKEAONMATION DETECTOR *P PHOTOELECTRIC SMOKE DETECTOR i HEATIPHOTOELECTRIC SMOKE DETECTOR [] tHr DUCT DETECTOR �} SPRINKLER SYSTEM FLOW SNITCH SPRINKLER SYSTEM TAMPERSWrrCH STROSE SMOKEIFIRE DAMPER CONNECTION `1 REMOTE INDICATOR LIGHT SECURITY SYSTEM O CONTACT DOOR SWITCH IN JAMB OR HINGE WRUS10N MOTION DETECTOR AS SPECIFIED, CORRIDOMOOM CORR IJ KEY - OPERATED ACCESS SWITCH SURVEILLANCE CAMERA DISTRIBUTION EQUIPMENT SYMBOLS �— DISCONNECT SWITCH --a1�— FUSES CIRCUIT BREAKER ^^e� -• CURRENT TRANSFORMER /VVV\ TRANSFORMER METER ® MAGNETIC MOTOR STARTER Ch D=ONNECTSWITCH PANELBOARD OR LOAD CENTER, FLUSH OR SURFACE MOUNTED SWiTCHBOW, MOTOR CONTROL CENTEROR DISMIM]TIO,N BOARD ® TRANSFORMER -- ^- •- -- GROUND CIRCUIT BREAKER MOTOR OUTLET ALTS AUTOMATIC TRANSFER SWITCH IMU i r + 3 CIRCUIT. NORTH LIGHTING PLAN __ _'* m N OR TH PO • f JTS AEC PROJECT* DATE: ISSUE: 08 -27 -10 PERMIT Drawn By: Checked By: SOH AEC r E1.0 • TO BE FROM THE SAME MANUFACTURER. SUBMIT SHOP DRAWING TO ENGINEER FOR REVIEW PRIOR TO ORDER. CD • •i • t • .! t t C. ) «• 0 • * • • co i • 0 ' t ' LL tp 4m- !] ! t • • •• < •• CO f UJ t IT • ! � i t s! • • • t •♦ +1 ti w AEC PROJECT* DATE: ISSUE: 08 -27 -10 PERMIT Drawn By: Checked By: SOH AEC r E1.0 • TO BE FROM THE SAME MANUFACTURER. SUBMIT SHOP DRAWING TO ENGINEER FOR REVIEW PRIOR TO ORDER. ELECTRICAL LEGEND (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) Q RECESSED OR SURFACE DOWNLIGHT CN WALL MOUNTED LIGHT FIXTURE - ABOVE FINISHED FLOOR RECESSED FLUOR. LIGHT FIXTURE - ABOVE FINISHED GRADE SURFACE FLUOR. LIGHT FIXTURE - AUTHORITY HAVING JURISDICTION FIXTURE DESIGNATIONS: - ALUMINUM UPPER CASE- FIXTURETYPE - COPPER LOWER CASE - SWITCH DESIGNATION - ELECTRICAL CONTRACTOR SHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUP 1•--{ FLUORESCENT STRIP FIXTURE F-y-x TRACK LIGHT AS NOTED OR SCHEDULED JI WALL WASHER f_1­0 POLE MOUNTED FIxTURE - GROUND POST (BOLLARD) FIXTURE 6 .1 STEP LIGHT (�} CEILING OR WALL MOUNTED EXIT LIGHT - NOTINCONTRACT EMERGENCY BATTERY LIGHTS • NIGHT LIGHT DUPLEX RECEPTACLE 0 18" UNLESS NOTED ! DOUBLE DUPLEX RECEPTACLE 0 181 UNLESS NOTED O FLUSH FLOOR DUPLEX RECEPTACLE REFERENCE SPECIAL OUTLET AS NOTED 4D DUPLEX RECEPTACLE HALRSWITCHED 0 ur UNLESS NOTED t) POP -UP RECEPTACLE i@ TELE -POWER POLE " MULTI-OUTLET PLUG STRIP I� V 01 JUNCTION BOX IN FLOOR, CEILING OR IN WAU- IR ♦ cOMPUTERrremoHoRE OUTLET IN FLOOR OR WALL "FAcP TELEVISION OUTLET ® TELEPHONE BACKBOARD Q CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING •- ----)b CIRCUIT HOMERUN — — — CONDUIT RUN BELOW FLOOR OR GRADE -3 CONDUIT STUB-UP. CAP & MARK *I LIGHT SWITCH AT W UNLESS NOTED OP SUBSCRIPTS: f H/P 2 = 2 -POLE SWITCH MIt 3 = 3-WAY SWITCH FE) 4 = 4-WAY SWITCH !t- M = MOTION - OPERATED SWITCH K = KEY - OPERATED SWITCH TO = THERMAL OVERLOAD SWITCH 1 1 P - SNITCH WITH PILOT LIGHT ® DIMMER SWITCH W! WATTAGE Q PUSHBUTTON CONTROL STATION + PHOTOELECTRIC CELL TIME SWITCH Q THERMOSTAT AT 80° UNLESS NOTED SURVEILLANCE CAMERA DIVISION 1S EQUIPMENT © FOOD SERVICE EQUIPMENT I I, COMMUNICATION SYSTEM CS}I SPEAKER IN CEILING OR WALL 0i VOLUME CONTROL AT 60" UNLESS NOTED *-I MICROPHONE OUTLET IN FLOOR BOX OR WALL. TRANSFORMER CALL -IN SWITCH ME'T'ER PROGRAM BELL MAGNETIC MOTOR STARTER INTERCOM DISCONNECT SWITCH CLOCK PANELBOARD OR LOAD CENTER, FLUSH OR SURFACE MOUNTED AMPLIFIER 1 SCOPE: Furnish all materials and labor required to execute this work as indicated on drawing and as specified, as necessary to complete the contract. Electrical work shall include, but not limited to, these major items: A. Complete wiring system for new lighting and power as shown, including new panelboards, new conduits, newwires, new wiring devices, new control devices, etc. for a complete lighting and and power system. a. Complete feeder(s) installation as required for new andtor electrical apparatus as shown on single tine diagram and drawings. b. Complete branch circuit wiring required for the connection of emergency lighting and exit signs to existing emergency stand by power system. 1 Complete provision, installation and connection of lighting fixtures, exit signs and lamps as specified and as shown on drawings. 3. Fire alarm system will be by electrical contractor. 4. Complete connection of HVACIPIumbing motor(s), water heater(s), equipment, etc. furnish by mechanical - refer to both electrical and and mechanical drawing for scope and work and additinal infor- mation. 5. Provide grounding and bonding Facilities. 6. Complete all electrical demolition as required. 7. Core drilling and patching of existing building structure required for electrical work. Core drilling shall follow Building Standard procedures and contractor shall have written approvals from building owner prior to start of any work. 8. Test of entire system and work. J. Operating, Maintenance and Identification instructions manuals, if any. 10. PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- tions, examinations and fees or charges necessary for execution and completion of electrical work. 11. REGULATIONS AND CODES: A. Applicable codes: National Electric Code (2008) Conform to the prevailing edition and amendments thereto of the Town of Vail Electrical Code, pertinent NFPA publications and to the requirements of Federal, State or other City agencies having jurisdiction, 12. SHOP DRAWINGS AND SUBMITTAL A. Contractor shall submit shop drawings for engineer review and approval. B. Shop drawing submittal shall include- 1. Lighting fixtures. 13. CONDUITANDWiRE: A. CONDUCTOR SIZES AND TYPES: Use only copper wire, 600 volt insulation, stranded in sizes #6 and larger. solid in sizes #10 and smaller. Control wiring shall be #14, stranded. in sizes #1 and smaller, use types TIN, THHN or THW. In sizes larger than #1, use THW or XHHW. Use type THHN for wires entering or passing through fluorescent lighting fixtures. B. MC cable permitted per local codes. 14. ELECTRICAL DEVICES A. Convenience receptacles will be 20 amp, commercial grade decora style. Finish per owner or architect B. Light switches will be 20 amp, commercial grade, decora style. Finish per owner or architect C. Dimming switches will be a minimum of 600w or as noted. Provide decora style, finish per owner or architect. D. All mounting heights will conform to ADA guidelines. Typical receptacle heights Will be +18 "AFF and switch heights Will be +46 AFF unless noted otherwise. E. Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc, as required by code. 15. SUPPORT A. Support all electrical equipment independent of accessible ceilings as required by NEC. 16. ELECTRICAL BOXES A. At fire rated wall space electrical boxes at opposite sides of the wall no less than 24" horizontal distance. B. When phone, TV & power receptacles are shown on plan next to each other. Locate respective receptacles next to each other on site with no more than 1" seperating cover plates. ABBREVIATIONS AC -ABOVE COUNTER AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AHJ - AUTHORITY HAVING JURISDICTION AL - ALUMINUM cu - COPPER EC - ELECTRICAL CONTRACTOR EM - EMERGENCY EMP - ENERGY MANAGEMENT PANEL EVIL - ELECTRIC WATER COOLER GC • GENERAL CONTRACTOR ONO - GROUND GF1 - GROUND FAULT INTERRUPTER MC - MECHANICAL CONTRACTOR NIC - NOTINCONTRACT NL • NIGHT LIGHT NTS - NOT TO SCALE PC - PLUMBING CONTRACTOR REF REFERENCE US - UNDERGROUND UTP - UNSHIELDED TWISTED PAIR WP - WEATHER PROOF XFMR - TRANSFORMER +18" - MOUNTING HEIGHT TO CENTERLINE A OF DEVICE AFF OR AFG FIRE ALARM SYSTEM "FAcP FIRE ALARM CONTROL PANEL ® FIRE ALARM ANNUNCIATOR PANEL Q FIRE ALARM PULL STATION �Q ALARM HORN OR SPEAKER I COMBINATION HORNISTROBE OR SPEAKERISTROBE • H THERMAL HEAT DETECTOR *I SMOKEIIONIZATION DETECTOR OP PHOTOELECTRIC SMOKE DETECTOR f H/P HEATIPHOTOELECTRIC SMOKE DETECTOR MIt DUCT DETECTOR FE) SPRINKLER SYSTEM FLOWSWITCH !t- SPRINKLER SYSTEM TAMPER SWITCH STROBE SMOKEIFIRE DAMPER CONNECTION 1 1 REMOTE INDICATOR LIGHT SECURITY SYSTEM CONTACT DOOR SWITCH IN JAMB OR HINGE INTRUSION MOTION DETECTOR AS SPECIFIED, WRRIOORMOM CORR QK KEY- OPERATEDACCESSSWITCH >= SURVEILLANCE CAMERA DISTRIBUTION EQUIPMENT SYMBOLS DISCONNECT SWITCH FUSES ^-- CIRCUIT BREAKER • -ka4=- CURRENTTRANSFORMER N/VW MM TRANSFORMER ME'T'ER ® MAGNETIC MOTOR STARTER C7 DISCONNECT SWITCH `i PANELBOARD OR LOAD CENTER, FLUSH OR SURFACE MOUNTED SWITCHBOARD. MOTOR CONTROL CENTM OR DIMMUTKON BOARD ® TRANSFORMER - • ---�10 GROUND CIRCUIT BREAKER @ MOTOR OUTLET [ RS I AUTOMATIC TRANSFER SWITCH 0 al. 2. I 3 CIRCUIT. e ba/:i _' .. -..-.w ._. ,_._____°_.. .,_.: _ ..,..._._ . ',„.«...-- ..,..:_�., _....•.«�:w;.:= „ �._.._ , t .. k.. rv:_»__._ .. : ._- � - �sx. , _a.,.,:._.,.. ._.. IR -=,.- 3 ».�._......,V.. � .._....._...._.. ....,.....__ >__.._a._,..._._ - ...._.._._... ..... �..__.., ., b..:...._,.___...,,,._ .,._,_. _.._ ,_...._::.�....,._ .. n_,.» ,.......,... I ,..�...- ....„. _... .._ ................. €� i ..3 '�! - �� "''7.1 ! ii.,.__..A._____.,..... v"'� _....__ � i.._m.�.o.....�...,....,a ..._� .., ..._.�,..��..._ .__... ,....... .,.». � ,_.�..,...n..� 1 NORITH L 1(ift H T I N G P LA N FUSE EXISTING CIRCUIT AREA. A2P COFFEE )INFIRM POWER REQUIREMENTS tIOR TO ROUGHIN :XISTING CIRCUIT SCALE: 114" = 17 AEC PROJECT* DATE: ISSUE: 08 -27 -10 PERMIT 10 - -10 REVISED LIGHTING Drawn By: Checked By: SOH AEC E1.0 !• •,r III •r a r. �i•r t� 1: C D •f A A { ! A � sf ! a) •f A • . 0) • ! f A • A A { co i ! A 1 • { A A • w Wow f { A f •f 1 / A ota ICU W f cu ! i coo { +5 A A ! •f A •f A if A AEC PROJECT* DATE: ISSUE: 08 -27 -10 PERMIT 10 - -10 REVISED LIGHTING Drawn By: Checked By: SOH AEC E1.0 !• •,r III •r a r. �i•r t� 1: