Loading...
HomeMy WebLinkAboutB10-0099 Plans++111+ S !t� ��Al/ • y_ - + 1. fir,► A y I% ,. * ► + •ir a y EX-2 EXI5TIN6 EAST ELEVATION 51 5EGONI) FLOOR • P LAN FLOO THIRD + 1 P LAN (5ENE NOTE R OO F 1► A INTERSTATE 10 HIGHWAY 6 .. + SORE GR'.EEr- VAIL VALLEY DRIVE VAIL VILLAGE FIL.IN6 7 5000ER FIELD - UNIT A -10 I 50ALE: N.T.S. NORTH ZON I N6 - LOO E)EN5 TY MULTI FAMILY wad r12, THE WORK WILL INCLUDE THE CONSTRUCTION OF A NEN DORMER ON THE EAST FAOING ROOF OF AN EXI5TIN6 MULTI- FAMILY BUILDING NHIGH WILL INCLUDE THE MODIFICATION OF THE EXI5TIN6 ROOF STRUCTURE, THE ADDITION OF NEW ROOF STRUCTURE, INSTALLATION OF NEW ROOFING OVEN.. THE NEW AND EXISTING ROOF AREAS IMPACTED BY THE ADDITION OF THE DORMER AND REPLACEMENT OF EXI5TINC WINDON5 AT THE NEW DORMER. 1. ALL NORK WILL BE COMPLETED IN ACCORDANCE WITH THE 200R EDITIONS OF THE "INTERNATIONAL BUILDING CODE" (IBC), INTERNATIONAL PLUMBING GODS, "INTERNATIONAL MECHANICAL CODE ", INTERNATIONAL FLUE CHAS GORE ", INTERNATIONAL ENERGY CODE ", "INTERNATIONAL FIRE GORE ", THE 2005 EDITION OF THE NATIONAL ELECTRICAL CODE AND TOWN OF VAIL ORDINANCE lb SERIES OF 200Q FOR ADOPTION OF THE ABOVE LISTED COTES. 2. THE EXISTING BUILDING HAS AN APPROVED AUTOMATIC SPRINKLED SYSTEM. MODIFICATIONS TO THE EXI5TIN6 SYSTEM, REQUIRED FOR THE ADDITION OF THE NEW DORMER SHALL BE MADE BY A DE516N BUILD COMPANY APPROVED TO WORK IN THE TOWN OF VAIL. PRIOR IOR TO THE START OF TH15 ASPECT OF THE NORK THEY WILL 505MIT A PLAN TO THE TOWN OF VAIL FIRE DEPARTMENT FOR APPROVAL. 3. THE EXISTING FUILDING HAS BEEN CLASSIFIED AS TYPE 111 --A. GON5TRUCTION. ALL NEW NORK NILL BE COMPLETED IN ACCORDANCE WITH TH15 CLASSIFICATION. 4. THE EX15T1N6 BUILDING HAS BEEN CLA551FiEP A5 AN R2 OCCUPANCY. ALL NEW WORK WILL BE COMPLETED IN ACCORDANCE WITH TH15 CLASSIFICATION. 5. EX15T €N6 RATED A55EMBLIE5 DAMAGED DURING CONSTRUCTION WILL BE REPAIRED TO PROVIDE THE ORIGINAL RATING AND PROTECTION. b. SHOULD ANY PENETRATIONS OF EX15TIN& WALL ASSEMBLIES AND FLOOR / CEILING ASSEMBLIES BE REQUIRED DUR.IN6 THE CONSTRUCTION PROCESS, THEY ARE TO BE SEALED IN ACCORDANCE WITH THE 150" AND WITH U.L. APPROVED ASSEMBLIES. THE CONTRACTOR WILL NOTIFY THE ARCHITECT OF ANY AND ALL SUCH PENETRATIONS, NHO WILL THEN PROVIDE THE REWIRED PENETRATION 5EALING ASSEMBLIES. 8. THE NEW NI DOW5 TO REPLACE THE EXISTING ARE TO METAL CLAD NOOD AND HILL HAVE A U- FACTOR OF 0.35 OR LESS KITH THE U- FACTOR LABELED ON EACH N1NDOPq UNIT BY THE MANUFACTURER. q. THE FOLLOWING ARE MINIMUM REQUIREMENTS - REFER TO PROPOSED ROOF PLAN SHEET A -2 FOR 5PEEC11FIC INFORMATION CONCERNING THE ACTUAL ROOF INSULATION TO BE PROVIDED. A. EXTERIOR WALL5 - R -215. B. ROOF - R, -38. 10. NEN ROOFING MATERIALS ARE TO BE IN COMPLIANCE W1TH A CLASS A ROOF. IT SHOULD BE NOTED THAT NOOK 5HAKE5 AND 5HINGLE5 ARE PROHIBITED. REFER TO ROOFING NOTE NO. I ON SHEET A-2. 11. NEN 5NON GUARD5 TO BE ADDED (SEE ROOF NOTE NO. 5 ON SHEET A -2. 12. THE VENTING OF THE EXISTING AND PROP05ED RAFTER SPACE WILL BE AVOIDED BY THE TYPE OF INSULATION AND VAPOR. BARRIER TO BE PROVIDED. REFER TO ROOF NOTE NO. 6 ON SHEET A--2. 13. THE EXTERIOR NALL FRAMING MATERIALS ARE TO BE FIRE- RETARDANT TREATED HOOD. fq amallols so W-4" "Wo q i A-4 UNIT A-$ UNIT A -10 UNIT A -I2 EXI5TIN& WALL FR,AMIN& AND SIDING MATERIALS TO BE CUT DONN OR AS REOUIRED E XTENDED WITH 51DIN6 TO BE REPLACED AS REQUIRED DUE TO DAMAGE CAUSED BY THE GUTTING PROCESS -- TH15 WALL 15 NOW A BEARING WALL- L E d*7 E N 1 0 .) 0 - FIRE RATED ASSEMBLY (REFER TO SHEET A -2) m 0 2'-W af-4* q { - 4 p N No EXTENT O FX1 5T. HN" { NEW STEEL COLUMN- VERIFY LOCATION (REFER TO ROOF I NOTE NO. 4 (SEE 5TRUGT) - -- - - - w LINE OF DORMER I � OOF ABOVE NNEN NINDON5 TO ALIGN WITH DOORS I BELOH (REFER TO BUILDING CODE NOTE NO. S ON SHEET A --0) {.{.��Jj. 1 V ! MISYMP e M i11MYB�.. . ! • ! . YIOtO.M i • M.Yilli • M Ms4p9i1. i I UNIT A -& UNIT A -IO S : I . THE CONTRACTOR 15 TO COORDINATE ALL V40RK KITH THE NORTHWOOD5 CONDOMINIUMS PROPERTY MANAGER, PRIOR TO THE START OF CONSTRUCTION AND AS REQUIRED DURING THE CONSTRUCTION PROCESS. 2. THE CONTRACTOR WILL VERIFY DAILY WORK START AND STOP TIMES WITH THE NORTHWOOD5 CONDOMINIUMS PROPERTY MANAGER. 3. ALL BUILDIW,; COMMON AREAS ADJACENT TO THE AREA OF WORK ARE TO SE PROTECTED AND KEPT GLEAN DURING THE ENTIRE HORK PROCESS. 4. THE GONTRAGTOR SHOULD NOTIFY THE ARCHITECT OF ANY DEFICIENCIES IN THE EXI5TIN& CONSTRUCTION AS IT RELATES TO GOUALITY, 5AFET't AND HUILDIN6 CODE ISSUES. , 5. ALL NEN MATERIALS AND FINI5HE5 ARE TO BE SELECTED BY THE CONTRACTOR AND APPROVED BY THE OWNER. 6. THE EXTERIOR WALL FRAMING MATERIALS ARE TO BE FIRE - RETARDANT TREATED WOOD. GYPSUM .SHEATHINGS GYPSUM WALLBOARD, WOOD STUDS L..�- -._... EXTERIOR SIDE.: Base layer 5 /6" type X gypsum sheathing applied parallel o r at right angles to 2 x 4 wood studs 24" o.c. with 6d coated nails, 1 long, 0.085" shank, 1 /4" heads, 24 " o.c. Face layer 5 /8" type X gypsum sheathing applied parallel or at right angles to studs with 8d coated nails, 2 long, 0.100" shank, Ile heads, 8 " o.c. Exterior cladding attached through sheathing to studs. INTERIOR SIDE: Base layer 5 /e" type X gypsum wallboard or gypsum veneer base applied pamlle or at right angles -to studs with 6d coated trails, 1 1e" long, 0.085" shank, 1 /4" heads, 24" o.c. Face layer s/e" type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to studs with 8d coated nails, 2 long, 0.100" shank, 1 /4" Thickness: 6 " without exterior cladding heads, 8" o,c. Fire Test: See`Wl? 4135 Joints staggered 24" each layer and side. (LOAD - BEARING) (FM WP 360, 9- 27 -74) GYPSUM WALLBOARD, WOOD JOISTS, ROOF COVERING i I Base layer sle " type X gypsum wallboard applied at right angles to 2 x 10 wood joists 24" o.c. with I'M' Type W or S drywall screws 24" o.c. Face layer e /e" type X gypsum wallboard or gypsum veneer base applied at right angles to joists with 1718" Type W or S drywall screws 12" o.c. at joints and intermediate joists and 1'le Type G drywall screws 12" o.c. placed 2" back on either side of end joints. Joints offset 24 " from base layer joints. Wood joists supporting Ili" plywood with exterior glue applied at right angles to joists with 8d nails. Appropriate roof covering. Ceiling provides one hour fire resistance protection for framing, including trusses, Approx. Ceiling Weight: 5 psf Fire Test: FIJI FC 972, 2- 25 - 72; ITS, 8 -6 -98 � 1 " ,rr a► �► .rr FLOOR 08 ROOF ITEM 4 3 2 i 4 3 2 9 CONSTRUCTION �i! MBER CEILING CONSTRUCT16 hoer hour hour horar Maur hour hour I hour 22. Steel joists, door trusses Base layer 1 /8" Type X gypsum board applied at and Bat or pitched roof trusses right angles to steel training 24" on center with V spaced a maximum 24" o.c. Type S drywall screws spaced 24" on center. Face with 1 l 2 " wood structural panels layer $I Type X gypsum: board applied at right with exterior glue applied at angles to steel framing attached through base right angles to top of joist: or 22 layer with 1 Type S drywall screws 12" on _ — — v aries __ - — V/4 top chord of trusses with Sao. 8 center at end joints and intermediate joints and screws. The wood structural 1 Type CG drywall screws 12 inches on center panel thickness shall not be less placed 2" back on either side of face layer end than nominal r / nor less than joints. Joints of the face layer are offset 24" from ljre ucl d �) Ch4pter 2 _ 1 1 _ __________ .__ _.._ _.._..... theme 'dints cif th ba se lq�q. A r GYPSUM WALLBOARD, STEEL COLUMN COVER Base [aye° 1/2" type X gypsum wallboard applied around TS4x4x0.188 tube steel column and held in place with paper masking tape. Second layer either No. 24 MSG galvanized steel column cover consisting of two L- shaped sections with snap -lock sheet steel joints or No. 22 MSG galvanized steel column covers consisting of two L- shaped sections with lap joints fastened with No. 8xm /2 " sheet metal screws 12" o.c. Dace layer mid" type X gypsum wallboard applied without horizontal joints to column cover with V Type S drywall screws 8" o.c. spaced 1" from vertical edges. Metal cornerbaad applied to all comers with V Type S drywall screws 12" o.c. in each flange. Fire Test: UL NC505- (1 -6), 71NK2639, 1223 -75; UL NC505, 77NK1518, UL Design X526 poill N OT +/► �:)2 5 (�4) �FJ5 6 ( 2 q-4* q-4n I T-4 q CII 1 EXISTING ROOFING TO BE REMOVED AND FULL COVERAGE SELF APHE51VE WATERPROOF MEMBRANE 15 TO 13E INSTALLED OVER THE 5OL1D SHEATHING ON THE EXISTIN COLD ROOF CONSTRUCTION AND NEW ROOFING TO MATCH EXISTING IS TO BE INSTALLED - -- -- EXISTING ROOF STRUCTURE TO REMAIN AND TO 13E MODIFIED (SEE STRUGT) APPROXIMATE LOCATION OF NEW ROOF BEAM (REFER. TO NOTE NO. 4) NEW DORMER ROOF (SEE 5TRUCT.) DASHED LINE INDICATES APPROX, FACE OF SIDING (TYPICAL) R NEW GUTTER WITH DOWNSPOUT 5NO N GUARD BY O (REFER TO NOTE NO. 5) -- FACE OF FRAMING AT SUB- FA5GIA (TYPICAL) LINE OF EXTENT OF EXISTING ROOF TO BE REMOVED AND EXISTING GUTTER TO 133E OUT BACK OR REPLACED AS REOUIRED (TYPICAL) -- EDGE OF ROOF (TYPICAL) /4' { _ ____ _ _ _ _EXISTING RIDGE_ __ - _ _ — _— �.._.._ —_ _ --____ _ _ _ _ � _ _ — _ —_ EL. +!- e 257' - - _ — $ ` �= -i_T _� �I r _ _ r _ _ _ _ _ _ — — _ _ — — — ..._. I LL_ _J �w ^1 IW $ _J lu EXISTING 5KYL16HT I I 1 TO REMAIN 1 __ ____ — Y! _._. — _-- ___ .....v_._. _T ®_.�.i 12 5 5.12 , �_ I I +/ -: +/ -I�) I� Ij ! U i WALL5 BELOW �I I ► V1wl�'.IFY VERIFY $ Z I...: w (TYPICAL) m - T_ ' I. I' IL h $ �z - /. II $ J ` � I PORTION OF EXISTING +/- 5:12 +/- 5:12 A-4 $ . I EI I ROOF STRUCTURE TO VERIFY VERIFY REMAIN AND BE TIED �+ INTO NEW DORMER C) I $ FRAMING AT VALLEY I I; —fit°°° � I o� - E .._.�._..._._.__.___ ---__ OH UN A-4 <_2 A-4 UNIT A -5 I UNIT A -10 FIELD VERIFY THE EXTENT OF EXISTING ROOFING TO BE REMOVED TO BE ABLE TO APPLY SELF ADHESIVE HATERPROOF MEMBRANE FROM THE EXISTING ROOF SHEATHING UP SUB- FASCIA OF DORMER ROOF AND BELOW MEMBRANE ON THE DORMER ROOF UNIT A -12 IN FIRE RATED ASSEMBLY (REFER TO THIS SHEET) ROOF NOTES b 1. THE EXISTING ROOFING 15 TO BE REMOVED IN THE AREA OF NEW CONSTRUCTION 5. THE DISPLAYED 5NOW GUARD 15 TO Be DESIGNED AND INSTALLED BY OTHERS AND REPLACED W1TH NEW ROOFING TO MATCH THE EXISTING AND WITH CONTRACTED WITH THE BUILDING ASSOCIATION, THE CONTRACTOR SHOULD MATERIALS THAT PROVIDE A CLASS "A" ROOF. PROVIDE PREFIN15HEP SHEET COORDINATE THIS WORK WITH THE DORMER CONSTRUCTION TO BE SURE THAT METAL VALLEY FLA5HIN65 AND DRIP FLA5HING5 AT THE EDGE OF ALL ROOFS. THE INSTALLATION DOES NOT HAVE A NEGATIVE IMPACT ON THE NEW FIELD VERIFY EXTENT OF EXISTING ROOFING TO BE REMOVED TO ACCOMPLISH WATERPROOFING AND ROOFING INSTALLATION. THE NEW CONSTRUCTION AND TO TIE IN THE NEW ROOFING. IT SHOULD BE NOTED THAT THE EXISTING ROOFING REFER5 TO NEW ROOFING TO BE INSTALLED BY 6. THE ENTIRE EXISTING AND NEW ROOF AREA BETWEEN GRID LINES 25 AND 25 OTHERS IN THE FALL OF 2010 AND DOES NOT REFER TO THE ROOFING AND FROM GRID LINE "A" TO THE EAST EDGE OF ROOF IS TO RECEIVE FULL PRESENTLY ON THE BUILDING. THE ROOFING WORK ADJACENT TO THE DEPTH BLOW -IN INSULATION Its ALL JOI5T 5PAGE5. PROVIDE THE " OPTIMA" CONSTRUCTION DESCRIBER IN THESE DRAHING5 WILL BE COMPLETED 13Y A L005E FILL FIBER GLASS INSU SYSTEM WITH "MEMBRANN " SMART VAPOR ROOFING INSTALLER WORKING DIRECTLY FOR THE 13UILDINO A55OC1ATION. THE RETARDER AS MANUFACTURED BY "CERTAIN TEE CORP." AS REQUIRED BY GENERAL CONTRACTOR 5HOULD COORDINATE WITH THE A55OCIATIONS THE TOWN OF `+/AIL BUILDING DEPARTMENT, THE INSULATION CONTRACTOR HILL ROOFING INSTALLER, PROVIDE SPECIFICATION AND OTHER DATA THAT WOULD CONFIRM THAT THE - CODE REG2UIRED JO15T SPACE VENTING CAN BE ELIMINATED. 2. PROVIDE FULL COVERAGE SELF ADHF51VE WATERPROOF MEMBRANE OVER THE SOLID SHEATHING OF THE EXISTING COLD ROOF CONSTRUCTION, OVER THE THE IN ADDITION TO THE JOIST SPACE IN5ULA1`ION, THE AREA ABOVE THE NEH ENTIRE NEW ROOF AREA, 15" UP ONTO SHEATHING OF ADJACENT 1NALL5 AND UP DORMER ROOF WILL RECEIVE A +/- 4 " THICK R161P INSULATED PANEL. WITH A CURB AT EXISTING SKYLIGHT, THE MEMBRANE SHOULD EXTEND OVER DRIP NAILABLE SURFACE, FLASHING AT ALL EDGES OF THE ROOF. 5. THE DIMEN51ON5 INDICATED FOR ROOF OVERHANG (OH) ARE FROM FACE OF STUN AT EXTERIOR WALL TO FACE OF 50 FA501A AT THE EAVES AND RAKES, 4, FIELD VERIFY THE LOCATION OF THE NEW STEEL BEAM AT THE INTERSECTION OF THE MODIFIED EXISTING BAR JOI5T5 AND NEW ROOF STRUCTURE AND AL50 HITH THE HEIGHT OF THE NEW DORMER RIDGE BEAM TO BE SURE THAT THE VALLEYS ON THE NEW DORMER OCCUR 1' -0" EAST OF THE CORNERS OF THE EXISTING SHED ROOF PORMER THE NORTH SIDE OF THE NEW DORMER AND ` �� } 5ET THE ADJACENT BUILDING ON THE SOUTH 51DE. t I IN • t y i • i� i i� NEW ROOFING TO MATCH AND REPLACE EX15TIN6 ON NEN AND MODIFIED EX15TINC7 ROOF 5TRUCTURE f5EE STRUCT) 5NON GUARD BY OTHERS (REFER TO ROOF NOTE NO. 5 ON SHEET A-2) A RIDGE EX15TIN651PINO ON ADJACENT BUILDING TO BE CUT BACK TO EXTEND HATERPROOFING FROM ROOF 5HEATHINry UP HALL AND TO INSTALL FLASHING PROPOSED RIP&E 4 5TRVC.J. PLYWOOD 4 'EL. +/- b250'-rl" NEW 45UTTER AND VONN5POUT TO MATCH EXISTING THIRD FLOOR O. SLA13 W EL. b24Z3'-1O" NEIN DORMER WITH FIN15H MATERIALS TO MATCH EX15TIN6 EXISTING RAILING TO REMAIN EX15TIN& P41NOOPq TO REMAIN FIR5T FLOOR / KT.0.5LAB EL. 6224'-(g" 0 EX15TIN6 kq00V51VINCl TO REMAIN MOM FIELD VERIFY THE EXTENT OF EX15TINCS ROOFING TO BE REMOVED TO BE ABLE TO APPLY SELF ADHE51VE P4ATERP•OF MEMBRANE FROM THE EX15TINO ROOF 5HEATHIN6 UP5U6-FA561A OF DORMER ROOF AND BELOW MEMBRANE ON THE DORMER ROOF 24 A -4 3 UNIT A-10 :2a :2 :26 :21 1 1 i � EX15TIN&SKYLIOHT TO REMAIN PORTION OF EXt5TINO ROOF TO BE REMOVED AND (5UTTER TO BE OUT BACK OR REPLACED AS REWIRED WITH NEW ONE TO MATCH EXISTING SHED ROOF TO REMAIN 12 =1 UNIT A•12 V • FIRE RATED A55E (REFER TO SHEET A-2) NOTE: FOR CLARITY TH1513UILPIN6 ELEVATION HAS BEEN PRAWN AT A POINT LOCATED BETWEEN THE WALL. ABOVE THE PARKMO GARAGE ENTRY AND THE FACE OF THE BUILDING WITH THE WALL AT THE 6ARAC7E ENTRY NOT DISPLAYED. NOTE: ALL NEW MATERIALS ARE TO MATCH EXISTING, ARE TO BE FIN1514W TO MATCH AND WILL INCLUDE BUT NOT BE LIMITEP TO ROOFINC7, HINVON5,61VIN6, FASCIAS, SOFFIT BOARDS, TRIM BOARDS AND FLA51-11N*5. N I Mid 0 0 1 SRI OR wr 6 -4 ; Vr.�? L N I Mid 0 0 1 SRI OR wr 6 EX15TIN6 HALL CONSTRUCTION TO REMAIN F"'AfkOT"MIAL 5" r= C T 1 �0` N "ok"'r- "OUTH AT I tv • EMIRS= ortnooft r ft *oft ago& • IN I Z;mIoo ,O wm CLEVATION ,A"k ,dff& 40 A T T H I 'm Z � f' L Q w c o; m ow" Em tomwla men CW^/Qo #%4 M E A =Oft T A A L EX15TINO ROOFING TO BE REMOVED AND NEW CLASS "A" ROOFING TO MATCH EXISTING 15 TO BE INSTALLED OVER FULL COVERAGE SELF ADHESIVE WATERPROOF MEMBRANE ON THE SOLID 5HEATHIN6 OF THE EX15TINCv COLD ROOF CONSTRUCTION NEW CLASS "A" ROOFING TO MATCH EXISTING OVER FULL COVERAGE SELF ADHESIVE K, MEMBRANE ON INSULATED PANEL WITH NAILABLE SURFACE IN5TALI ED ON THE STRUCTURAL PLYV40012 SHEATHING NEW VORMER ROOF 5T'RUGTlJRE WITH STEEL RIDGE BEAM, BENT STEEL SUPPORT BEAM AND 2x RAFTERS AND OUTRIGGERS AT EAST EN12 OF ROOF (SEE 9 RIDGE Z.O. PLYV4000 ' +/- 525 FULL DEPTH BLOW --IN INSULATION IN J015T SPACES ON EACH 5112E OF STEEL BEAM (REFER TO ROOF NOTE NO. 6 ON SHEET A-3) PROPOSED R1126F 4 " +/- TYPICAL. FA501A AND SOFFIT CONSTRUCTION TO MATCH EXISTING 2x DROP CEILING-, J015TS SET AT BOTTOM OF NEW BENT STEEL BEAM: THIRD FLOOR �T.0.51-AB ' D EL.. 8243 START OF SLOPPED GEILIN6 AT WALL BEYOND EXISTING ROOF AND STEEL BEAM TO BE REMOVED EXISTING DEGK TO REMAIN SECOND FLOOR T.O. SLAB EL. b234-2" START OF SLOPPED CEILING AT MALL NEW SOUND INSULATED WINDOW WITH TRIM TO MATCH EXISTING EX15TIN6 COUNTER AND SINK TO REMAIN I= MIN q'-4m W-4 q'-4 q'-4" EX15TIN& RID&E - — — — — — — — — — — - I -- - - - - - - - I i �� -� -- �l 1 � � I � � � s I EL. e�251- J LL 7 W __j IL - - - - - - - - - - i ��� � � � � II ��� -� I I I SKYLICvHT _ ______�_ ==- �S_ �� I � r - ____ _� �______ __ _____ --- — — — — — — — — I III f � II !!� !I� ii 1 NALL5 BELOW -OP, I (! i (TYPIOAL) ( I f I I I III I�I 5:12 5:12 --------------- --------- I � i I l III w = 1 1 1 VERIFY VERIFY i t ({ j � p � I I 11 ;i� + kb w Uj JL j - - - - - - - - - -- - - - UNIT A-& , I. UNIT A-10 I UNIT A f=XISTIN& rr R001= PLAN Q7 50ALE: 1/4" = V-O" PLAN NORTH Sheet Number =am OL Ty < X < OL CL Sheet Number =am A,EX15T[N(5 RIDGE- +/ 025 THIRD FLOOR ,,KT.O. 5LAP "'EL. b243'-10" 5ECONV FLOOR T.U. 5LA-M ' 8254'-2` FIRST FLOOR T.O. SLAB 4 "EL. 5224'46" UNIT A-8 UNIT A-10 u UNIT A-12 UNIT TO BE REMODELED "Em X 15 T I O N& E At"p"T ELEVATION SCALE. 1/4' = 1'-0" NOTE: FOR CLARITY TH15 BUILDING ELEVATION HA5 BEEN VRAv4N AT A POINT LOCATED BETWEEN THE Y4ALL ABOVE THE PARKING GARAGE ENTRY AND THE FACE OF THE DUILPIN& V41TH THE 1NALL AT THE GARAGE ENTRY NOT V15PLAYED. logo 1 2:2 :21� :2a :2.4 :26 .2 28 I DESIGN CRITERIA: Northwoods A10 Dormer JOB #: 1003-03 Roof Live Load (Sno -------------------------------- 80 pof Roof Dead Load ------------------------------------ 20 paf Wind (3 Second Gust) -------------------------------- 90 mph (Exp. B) Seismic Design Category ------------------------------- B |BC/IRCEditiom ------------------------------------ 2009 There is no new floor area or roof area odded, the existing roof form has been altered to create the dormer. According to {BC 1614.3, the alterations to the structure do not (nonwooe the seismic force in or deonaoao the design strength of any resisting structural element in the building by more than 5%. STRUCTURAL WOOD FRAMING: o. Except where noted otherwise, all 2" norn|no| lumber, except studs, ahoU be Douglas Fir—Larch and better, and all solid timber beorno and posts 3" nominal and wider ohoU be Douglas Fir—Larch b. Studs shall be Stud grade and bettor Douglas Fir—Larch or Henn Fir. C. Except as noted otherwise, rnln|rnurn nailing shall be provided as specified in the "Fastening 3chedV|e" /2000 IBC Table 2304.8.1\. d^ Un|aoo noted otherwise, steel connectors such as those manufactured by the Simpson Company nhoU be used to join rafters, j or beunnm to other bworno at flush—framed conditions. Use all specified nails. Connector conditions not otherwise noted ahoU utilize Type U or Type HU hangers of o size opooiMooUy designed for the rn*rnber supported, as ehnvvn in the manufacturer's published tables. Contact structural engineer for details as required. w. Wood nailer plates installed on steel boorna for top—flange hangers shall be ripped to match the width of the wall or beam flange. Nailer plates supporting top flange hangers from one side only ohoU be installed flush with the face of beam flange at the hanger locations. t All lumber used in construction shall have o nloxinlurn moisture content of 19% and shall be treated non—combustible.. i \6' g. 1. Roof Construction: C. Construction practices: General contractor is responsible for means, methods, techniques, A. Provide 5/8" think APA plywood sheathing rated 40/20\ exposure 1. Install sequences and procedures for construction of this project. Notify structural engineer of sheathing with long dimension perpendicular to rafters or trusses and end j omissions or conflicts between the working drawings and existing conditions. Coordinate staggered. Nail with 8d noi{a spaced at 8" along panel edges and at 12" a long requirements for mechanical/electrical/plumbing penetrations through structural elements with intermediate supports. structural engineer. Joba|ta safety is the ao}w responsibility of the contractor. All methods B. Provide wind/seismic anchors at supports for oU joists. sts. See nailing schedule. used for construction shall be in accordance with the latest editions of the |BC�R��, C. Provide solid' blocking between roof rafters and lookou ' at all bearing locations. d' Details not specifically shown on the drawings ohoU be constructed in o manner airnUor to the Blocking material nhoU rnotoh depth of rafter or lookout material. details that are shown for like conditions. These |terna ohoU be brought to the attention of the structural engineer as soon as possible for approval. Approval shall be obtained prior to STRUCTURAL STEEL: installation. e. All waterproofing and flashing is the responsibility of the architect and contractor. o. Structural steel uhoU be detuUed, fabricated and erected in accordance with the most current t It is the responsibility of the contractor to contact the structural engineer at the appropriate editions of A|SC Specifications and Code of Standard Pruot|oe' time to perform site observation visits. Observation visits to the ' bsite by the engineer are b. Structural steel VV shapes ohoU be ASTW A892' Other rolled shapes, including okztos and for determination of general conformance with the construction dnourneDto and shall not be angles ohoU be A3TN A36, Round or rectangular HSS shapes shall be ASTW A500 grade B. construed as inspection. C. All bolts used in steel framing shall conform to ASTIVI Spe A325. Bolt sizes ohoU be g' Though every effort is made to provide o complete and clear set of construction documents, �4`0 unless noted otherwise. discrepancies or omissions may occur. Release of these drawings anticipates cooperation and A | we|ding shall be done by on AVYS qualified w�|d� ' |oy continued communication between the contractor, architect and engineer to provide the beet ' Delay pointing within 3" of field welds until welds one onrnp|eted^ possible otruoture. Those drawings have been prepared for the use of o qualified contractor experienced in the construction techniques and systems depicted. GENERAL REQUIREMENTS: h. Existing structures: Contractor shall be responsible for verifying dirnenainns, e}evotion$, framing, foundation and anything o|ae that may affect the work shown on the drawings. o ' Structural erection and bracing: The structural drawings illustrate the completed structure Underpinning, shoring and bracing of existing structures eho|| be the responsibility of the rted ond braced. The contractor, |n with all elements in their final positions, properly supported ^ ontrootor. the proper nequenoe, shall provide shoring and bracing as may be required during construction to achieve the final completed structure. Contact structural engineer for consultation /not in contract) as required. b. Dimensions: Check all dimensions against architectural drawings prior to construction. Do not 000!e drawings. ! | | NOTE: CONTACT ENGINEER WHEN (E) IlRAMING IS EXPOSED, VERIFY ALIGNMENT OF W8 MAY NOT BE REQUIRED IF (E) BM. W/ (N) BRG. SUFFICIENT BLOCKING IS WALL ABOVE EXISTING hJO�TA '`~^'^''' FLOOR FRAMING PLAN SCALE: 1 /4" V-0" r-A - u FRAMING PLAN SCALE: 1/4" = V-0 )1 %" PLYWD. ON 2x4 NAILERS ON (E) 16" BAR JOISTS BEYOND (SEE SECT. 1/S2 FOR NEW BEARING CONDITION) (N) HSS3x3x'Yls COL. BRG. F�: Y2 "x4 "x0' -8 WELDED TO BM. & COL. 04; ; ,, i • (N) MC10x25 CONT., WEB PUNCHED FOR Y" O PLUG WELDS @ 12" O.C. ALONG TOP & BOT. (E) C1 2x20.7 SCALE: 3/4" = 1' —O" (N) W12x19 --f JL3x3x- 6x0' -8Y WELDED TO BOTH BM. WEBS SCALE: 3/4" = 1' —O" 11 II ICI (E) W6 COL. I II 1 8 1 illl Illf 3 (j L6x4x —Q SCALE: 3/4" = 1' -0" SOLID BLKG. BTWN. LOOKOUTS @ BRG., TYP. (4) -10d NAILS INTO ` EA. LOOKOUT, TYP. \ EQ. L 2x12 STRUCTURAL SUB — FASCIA, TYP. 2x12 LOOKOUTS --� @ 24" O.C., TYP. (3) -2x10 SLOPING HEADER (N) 2x12 RAFTERS @ 24" O.C. EQ. RIDGE C ONT. ` PACK : : • r F OR RAFTER HANGE (E) C1 2x20.7 SLOPING BM. CAP. T: Y "x4 "x0' -8 W/ (2) -%`0 THRU —BOLTS (N) HSS3x301'6 COL. %" PLYWD. ON 2x12 RAFTERS @ 24" r• i - - . . - -. / . )f � , ...,1 (E) 5 /s" PLYWD. ON CONT. 2x4 NAILER (E) JOIST TOP CHORD L3x3xY4xO' -4 EA. SIDE (BEVEL TOP TO MATC1• ROOF PITCH) CAP T: Y2 "xBM. WIDTH x0' -8 W/ (2) -3 /4 " 0 THRU— BOLTS. (1) —EA. SIDE OF WEB. (N) HSS 3x3xY4 IN STUDPACK BTWN. WINDOWS 1/4 l4 rIi ILU JirNM- EA. SIDE SIMPSON LSSU210, TYP, (N) BENT W8x35 BM." (N) W8x21 RIDGE BM.— W/ CONT. 2x NAILER I JL3x3x- 6x0' -5Y WELDED TO BOTH BM. WEBS �r -� S-- - -(E) 16" BAR JOISTS, J ' CUT OFF AT (N) BM. ' ADD L1Yx1Y2xY8 TO WEB EA. SIDE [(E) WEB CONFIGURATION MAY VARY] (N) W12x19 BM. UNDERFRAME CEILING TO MATCH DEPTH OF (E) 16" BAR JOISTS SCALE: 3/4" = 1' —O" N OTES ROOF FRAMING PL-AN. PLAN •• NEW FRAMING: 1. NEW POSTS BELOW (ORIGINATING FROM THIS LEVEL OR ABOVE) ARE INDICATED: ,a EXISTING POSTS BELOW (ORIGINATING FROM THIS LEVEL OR ABOVE) ARE INDICATED: 04 NON— CONTINUOUS POSTS FROM ABOVE OR CRIPPLE POSTS ARE INDICATED: 0 SINGLE STUD TRIMMERS THAT DO NOT REQUIRE BLOCKING BELOW ARE INDICATED: 2. ALL POSTS ARE LABELED AT THE TOP. 3. NEW ROOF SHEATHING IS 5 /8" APA RATED SHEATHING, EXP.1, SPAN RATING 40/20. 4. NEW ROOF BEAMS, EXCEPT HEADERS, ARE FLUSH FRAMED UNLESS NOTED AS (DROPPED). 5. ALL NEW ROOF RAFTERS ARE: 2x12's 0 24 ", TYPICAL, UNLESS NOTED OTHERWISE. 6. (E) REFERS TO EXISTING CONSTRUCTION ( ), (N) REFERS TO NEW ( � SCALE: 1 /4" = 1,_O„