Loading...
HomeMy WebLinkAboutB11-0017 Asbestos Report Lionshead Subway Building Indoor Environmental Services, Inc Dba: Q Consulting, Inc. Structure Inspected Lionshead Subway Building Asbestos Inspection Report — Page 1 of 2 February 25, 2011 Tom Kassmel Town of Vail On February 23, 2011, Quentin Danziger conducted an asbestos inspection of the suspect materials throughout the building. Asbestos was NOT found, as described below. Homogenous Description Number of % Asbestos Square Type/Friable? Area Sam les Feet O1 Texture 5 Non Detect 02 Sheetrock/JC 5 Non Detect 03 Cove Base 3 Non Detect Mastic 04 VRC Upper 3 Non Detect Floor Tile OS VRC Lower 3 Non Detect Floor Tile 06 Subway Floor 3 Non Detect Tile 07 VRC Lower 3 Non Detect Carpet Mastic 08 VRC Upper 3 Non Detect Carpet Mastic 09 Window 3 Non Detect Caullcing 10 White 3 Non Detect Caullcing BACKGROUND: This building is scheduled for complete demolition. This is the pre-demolition inspection. This inspection includes only suspect materials that are visible to the inspector. If other suspect materials become visible during demolition, they must be sampled before they are disturbed. Examples of suspect materials include but are not limited to: linoleum, Indoor Environmental Services, Inc Dba: Q Consulting, Inc. Structure Inspected Lionshead Subway Building Asbestos Inspection Report — Page 2 of 2 floor tile, ceiling tile, mastic, sheetrock,joint compound, roofing materials, etc. There are over 3000 known asbestos containing materials. SAMPLING PLAN: Colorado State Requirements - For each homogenous area of less than 1000 square feet, a minimum of three samples must be collected in random areas. For each homogenous area of 1000— 5000 square feet, a minimum of five samples must be collected in random areas. Areas of 5001 square feet or greater require a minimum of 7 samples. These laws are defined by the EPA (AHERA) and Colorado State Regulation 8. Determination of homogenous sampling areas—Homogenous Areas are determined by type of suspect material, texture, color and location. Determination of random sampling areas—The samples were collected in a random manner. Thank you for using Q Consulting, Inc. We are proud to be your local indoor air quality consultants. We look forward to working with you in the future. Quentin Danziger, BS, CIE, ABI—Colorado Asbestos Inspector Certification# 12781 Indoor Environmental Services, Inc. Dba Q Consulting, Inc. 970-390-0087 QConsultingInc@yahoo.com EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom Attn: Quentin Danziger Customer ID: INES78 Q Consulting, IIIC. Customer PO: PO Box 997 Received: 02/24/11 8:45 AM Vail, CO 81658 EMSL Order: 221100615 Fax: Phone: (970)390-0087 EMSL Proj: Town of Vail Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 01-01 Texture White 100% Non-fibrous(other) None Detected z2tioosis-000i Non-Fibrous Homogeneous 01-02 Te�ure White 100% Non-fibrous(other) None Detected zziioosis-000z Non-Fibrous Homogeneous 01-03 Texture White 100% Non-fibrous(other) None Detected 221100615-0003 Non-Fibrous Homogeneous 01-04 Te�ure White 100% Non-fibrous(other) None Detected 221100615-0004 Non-Fibrous Homogeneous 01-05 Texture White 100% Non-fibrous(other) None Detected 221100615-0005 Non-Fibrous Homogeneous 02-01-Texture Sheetrock/Joint White 100% Non-fibrous(other) None Detected zziioosis-000s Compound Non-Fibrous Homogeneous 02-01-Joint Sheetrock/Joint Beige 100% Non-fibrous(other) None Detected Compound Compound Non-Fibrous 221100615-OOO6A Homogeneous Initial report from 02/24/2011 16:12:24 I Analyst(s) DeCavallas Michael(29) Erin Orthun,Laboratory Manager Molly Walker(23) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0 Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM � EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom Attn: Quentin Danziger Customer ID: INES78 Q Consulting, IIIC. Customer PO: PO Box 997 Received: 02/24/11 8:45 AM Vail, CO 81658 EMSL Order: 221100615 Fax: Phone: (970)390-0087 EMSL Proj: Town of Vail Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 02-01-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected zziioosis-000se Compound Fibrous Heterogeneous 02-02-Te�ure Sheetrock/Joint White 100% Non-fibrous(other) None Detected zziioosis-000� Compound Non-Fibrous Homogeneous 02-02-Joint Sheetrock/Joint Beige 100% Non-fibrous(other) None Detected Compound Compound Non-Fibrous 221100615-0007A Homogeneous 02-02-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected zziioosis-000�e Compound Fibrous Heterogeneous 02-03-Te�ure Sheetrock/Joint White 100% Non-fibrous(other) None Detected zziioosis-000s Compound Non-Fibrous Homogeneous 02-03-Joint Sheetrock/Joint Beige 100% Non-fibrous(other) None Detected Compound Compound Non-Fibrous 221100615-OOO8A Homogeneous Initial report from 02/24/2011 16:12:24 I Analyst(s) DeCavallas Michael(29) Erin Orthun,Laboratory Manager Molly Walker(23) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0 Test Report PLM-7.23.0 Printed:2/24/2011 4:1224 PM 2 EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom Attn: Quentin Danziger Customer ID: INES78 Q Consulting, IIIC. Customer PO: PO Box 997 Received: 02/24/11 8:45 AM Vail, CO 81658 EMSL Order: 221100615 Fax: Phone: (970)390-0087 EMSL Proj: Town of Vail Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 02-03-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected zziioosis-000se Compound Fibrous Heterogeneous 02-04-Te�ure Sheetrock/Joint White 100% Non-fibrous(other) None Detected zziioosis-000s Compound Non-Fibrous Homogeneous 02-04-Joint Sheetrock/Joint Beige 100% Non-fibrous(other) None Detected Compound Compound Non-Fibrous 221100615-0009A Homogeneous 02-04-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected zziioosis-000se Compound Fibrous Heterogeneous 02-05-Texture Sheetrock/Joint White 100% Non-fibrous(other) None Detected zziioosis-ooio Compound Non-Fibrous Homogeneous 02-05-Joint Sheetrock/Joint White/Beige 100% Non-fibrous(other) None Detected Compound Compound Non-Fibrous 221100615-OOlOA Homogeneous Initial report from 02/24/2011 16:12:24 I Analyst(s) DeCavallas Michael(29) Erin Orthun,Laboratory Manager Molly Walker(23) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0 Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM 3 EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom Attn: Quentin Danziger Customer ID: INES78 Q Consulting, IIIC. Customer PO: PO Box 997 Received: 02/24/11 8:45 AM Vail, CO 81658 EMSL Order: 221100615 Fax: Phone: (970)390-0087 EMSL Proj: Town of Vail Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 02-05-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected zziioosis-ooioe Compound Fibrous Heterogeneous 03-01 Cove Base Yellow 100% Non-fibrous(other) None Detected zziioosis-ooii Mastic-Upper Non-Fibrous Homogeneous 03-02 Cove Base Yellow 100% Non-fibrous(other) None Detected zziioosis-ooiz Mastic-Upper Non-Fibrous Homogeneous 03-03 Cove Base Tan 100% Non-fibrous(other) None Detected 221100615-0013 Mastic-Lower Non-Fibrous Homogeneous 04-01-Floor Tile VRC Upper Floor Tan 100% Non-fibrous(other) None Detected 221100615-0014 Tile Non-Fibrous Homogeneous 04-01-Mastic VRC Upper Floor Clear 100% Non-fibrous(other) None Detected 221100615-0014A Tile Non-Fibrous Homogeneous 04-02-Floor Tile VRC Upper Floor Tan 100% Non-fibrous(other) None Detected 221100615-0015 Tile Non-Fibrous Homogeneous Initial report from 02/24/2011 16:12:24 � Analyst(s) DeCavallas Michael(29) Erin Orthun,Laboratory Manager Molly Walker(23) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0 Test Report PLM-7.23.0 Printed:2/24/2011 4:1224 PM 4 EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom Attn: Quentin Danziger Customer ID: INES78 Q Consulting, IIIC. Customer PO: PO Box 997 Received: 02/24/11 8:45 AM Vail, CO 81658 EMSL Order: 221100615 Fax: Phone: (970)390-0087 EMSL Proj: Town of Vail Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 04-02-Mastic VRC Upper Floor Clear 100% Non-fibrous(other) None Detected 221100615-0015A Tile Non-Fibrous Homogeneous 04-03-Floor Tile VRC Upper Floor Tan 100% Non-fibrous(other) None Detected zziioosis-oois Tile Non-Fibrous Homogeneous 04-03-Mastic VRC Upper Floor Clear 100% Non-fibrous(other) None Detected 221100615-0016A Tile Non-Fibrous Homogeneous 05-01 VRC Lower Floor Tan 100% Non-fibrous(other) None Detected zziioosis-oon Tile Non-Fibrous Heterogeneous 05-02 VRC Lower Floor Tan 100% Non-fibrous(other) None Detected zziioosis-oois Tile Non-Fibrous Heterogeneous 05-03 VRC Lower Floor Tan 100% Non-fibrous(other) None Detected zziioosis-oois Tile Non-Fibrous Heterogeneous 06-01 Subway Floor Tile Tan 100% Non-fibrous(other) None Detected zziioosis-oozo Non-Fibrous Homogeneous Initial report from 02/24/2011 16:12:24 � Analyst(s) DeCavallas Michael(29) Erin Orthun,Laboratory Manager Molly Walker(23) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0 Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM 5 EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom Attn: Quentin Danziger Customer ID: INES78 Q Consulting, IIIC. Customer PO: PO Box 997 Received: 02/24/11 8:45 AM Vail, CO 81658 EMSL Order: 221100615 Fax: Phone: (970)390-0087 EMSL Proj: Town of Vail Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 06-02-Floor Tile Subway Floor Tile Tan 100% Non-fibrous(other) None Detected z2tioosis-oozi Non-Fibrous Homogeneous 06-02-Mastic Subway Floor Tile Yellow 100% Non-fibrous(other) None Detected 221100615-0021A Non-Fibrous Homogeneous 06-03-Floor Tile Subway Floor Tile Tan 100% Non-fibrous(other) None Detected z2iioosis-oozz Non-Fibrous Homogeneous 06-03-Mastic Subway Floor Tile Yellow 100% Non-fibrous(other) None Detected 221100615-0022A Non-Fibrous Homogeneous 07-01-Mastic VRC Lower Carpet Yellow/Clear 100% Non-fibrous(other) None Detected 221100615-0023 Mastic Non-Fibrous Heterogeneous 07-01-Leveler VRC Lower Carpet White 100% Non-fibrous(other) None Detected 221100615-0023A Mastic Non-Fibrous Homogeneous 07-02-Mastic VRC Lower Carpet Yellow/Clear 100% Non-fibrous(other) None Detected 221100615-0024 Mastic Non-Fibrous Heterogeneous Initial report from 02/24/2011 16:12:24 � Analyst(s) DeCavallas Michael(29) Erin Orthun,Laboratory Manager Molly Walker(23) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0 Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM 6 EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom Attn: Quentin Danziger Customer ID: INES78 Q Consulting, IIIC. Customer PO: PO Box 997 Received: 02/24/11 8:45 AM Vail, CO 81658 EMSL Order: 221100615 Fax: Phone: (970)390-0087 EMSL Proj: Town of Vail Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 07-02-Leveler VRC Lower Carpet White 100% Non-fibrous(other) None Detected 221100615-0024A Mastic Non-Fibrous Homogeneous 07-03-Mastic VRC Lower Carpet Yellow/Clear 100% Non-fibrous(other) None Detected 221100615-0025 Mastic Non-Fibrous Heterogeneous 07-03-Leveler VRC Lower Carpet White 100% Non-fibrous(other) None Detected 221100615-0025A Mastic Non-Fibrous Homogeneous 08-01 VRC Upper Carpet Tan 100% Non-fibrous(other) None Detected zziioosis-oozs Mastic Non-Fibrous Heterogeneous 08-02 VRC Upper Carpet Tan 100% Non-fibrous(other) None Detected zziioosis-ooz� Mastic Non-Fibrous Heterogeneous 08-03 VRC Upper Carpet Tan 100% Non-fibrous(other) None Detected zziioosis-oozs Mastic Non-Fibrous Heterogeneous 09-01 Window Caulking Gray/Clear 100% Non-fibrous(other) None Detected zziioosis-oozs Non-Fibrous Heterogeneous Initial report from 02/24/2011 16:12:24 � Analyst(s) DeCavallas Michael(29) Erin Orthun,Laboratory Manager Molly Walker(23) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0 Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM � EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom Attn: Quentin Danziger Customer ID: INES78 Q Consulting, IIIC. Customer PO: PO Box 997 Received: 02/24/11 8:45 AM Vail, CO 81658 EMSL Order: 221100615 Fax: Phone: (970)390-0087 EMSL Proj: Town of Vail Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 09-02 W indow Caulking Gray/Clear 100% Non-fibrous(other) None Detected 221100615-0030 Non-Fibrous Heterogeneous 09-03 W indow Caulking Gray/Clear 100% Non-fibrous(other) None Detected 221100615-0031 Non-Fibrous Heterogeneous 10-01 W hite Caulking Gray/W hite 100% Non-fibrous(other) None Detected 221100615-0032 Non-Fibrous Heterogeneous 10-02 W hite Caulking Gray/W hite 100% Non-fibrous(other) None Detected 221100615-0033 Non-Fibrous Heterogeneous 10-03 W hite Caulking Gray/W hite 100% Non-fibrous(other) None Detected 221100615-0034 Non-Fibrous Heterogeneous Initial report from 02/24/2011 16:12:24 Analyst(s) DeCavallas Michael(29) Erin Orthun,Laboratory Manager Molly Walker(23) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0 Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM THIS IS THE LAST PAGE OF THE REPORT. $