HomeMy WebLinkAboutB11-0017 Asbestos Report Lionshead Subway Building Indoor Environmental Services, Inc
Dba: Q Consulting, Inc.
Structure Inspected
Lionshead Subway Building
Asbestos Inspection Report — Page 1 of 2
February 25, 2011
Tom Kassmel
Town of Vail
On February 23, 2011, Quentin Danziger conducted an asbestos inspection of the suspect
materials throughout the building. Asbestos was NOT found, as described below.
Homogenous Description Number of % Asbestos Square Type/Friable?
Area Sam les Feet
O1 Texture 5 Non Detect
02 Sheetrock/JC 5 Non Detect
03 Cove Base 3 Non Detect
Mastic
04 VRC Upper 3 Non Detect
Floor Tile
OS VRC Lower 3 Non Detect
Floor Tile
06 Subway Floor 3 Non Detect
Tile
07 VRC Lower 3 Non Detect
Carpet Mastic
08 VRC Upper 3 Non Detect
Carpet Mastic
09 Window 3 Non Detect
Caullcing
10 White 3 Non Detect
Caullcing
BACKGROUND:
This building is scheduled for complete demolition. This is the pre-demolition
inspection.
This inspection includes only suspect materials that are visible to the inspector. If other
suspect materials become visible during demolition, they must be sampled before they
are disturbed. Examples of suspect materials include but are not limited to: linoleum,
Indoor Environmental Services, Inc
Dba: Q Consulting, Inc.
Structure Inspected
Lionshead Subway Building
Asbestos Inspection Report — Page 2 of 2
floor tile, ceiling tile, mastic, sheetrock,joint compound, roofing materials, etc. There are
over 3000 known asbestos containing materials.
SAMPLING PLAN:
Colorado State Requirements - For each homogenous area of less than 1000 square
feet, a minimum of three samples must be collected in random areas. For each
homogenous area of 1000— 5000 square feet, a minimum of five samples must be
collected in random areas. Areas of 5001 square feet or greater require a minimum of 7
samples. These laws are defined by the EPA (AHERA) and Colorado State Regulation 8.
Determination of homogenous sampling areas—Homogenous Areas are determined by
type of suspect material, texture, color and location.
Determination of random sampling areas—The samples were collected in a random
manner.
Thank you for using Q Consulting, Inc. We are proud to be your local indoor air quality
consultants. We look forward to working with you in the future.
Quentin Danziger, BS, CIE, ABI—Colorado Asbestos Inspector Certification# 12781
Indoor Environmental Services, Inc.
Dba Q Consulting, Inc.
970-390-0087
QConsultingInc@yahoo.com
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112
Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom
Attn: Quentin Danziger
Customer ID: INES78
Q Consulting, IIIC. Customer PO:
PO Box 997 Received: 02/24/11 8:45 AM
Vail, CO 81658 EMSL Order: 221100615
Fax: Phone: (970)390-0087
EMSL Proj: Town of Vail
Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance % Fibrous % Non-Fibrous % Type
01-01 Texture White 100% Non-fibrous(other) None Detected
z2tioosis-000i Non-Fibrous
Homogeneous
01-02 Te�ure White 100% Non-fibrous(other) None Detected
zziioosis-000z Non-Fibrous
Homogeneous
01-03 Texture White 100% Non-fibrous(other) None Detected
221100615-0003 Non-Fibrous
Homogeneous
01-04 Te�ure White 100% Non-fibrous(other) None Detected
221100615-0004 Non-Fibrous
Homogeneous
01-05 Texture White 100% Non-fibrous(other) None Detected
221100615-0005 Non-Fibrous
Homogeneous
02-01-Texture Sheetrock/Joint White 100% Non-fibrous(other) None Detected
zziioosis-000s Compound Non-Fibrous
Homogeneous
02-01-Joint Sheetrock/Joint Beige 100% Non-fibrous(other) None Detected
Compound Compound Non-Fibrous
221100615-OOO6A
Homogeneous
Initial report from 02/24/2011 16:12:24 I
Analyst(s)
DeCavallas Michael(29) Erin Orthun,Laboratory Manager
Molly Walker(23) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL
bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be
used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a
problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM �
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112
Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom
Attn: Quentin Danziger
Customer ID: INES78
Q Consulting, IIIC. Customer PO:
PO Box 997 Received: 02/24/11 8:45 AM
Vail, CO 81658 EMSL Order: 221100615
Fax: Phone: (970)390-0087
EMSL Proj: Town of Vail
Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance % Fibrous % Non-Fibrous % Type
02-01-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected
zziioosis-000se Compound Fibrous
Heterogeneous
02-02-Te�ure Sheetrock/Joint White 100% Non-fibrous(other) None Detected
zziioosis-000� Compound Non-Fibrous
Homogeneous
02-02-Joint Sheetrock/Joint Beige 100% Non-fibrous(other) None Detected
Compound Compound Non-Fibrous
221100615-0007A
Homogeneous
02-02-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected
zziioosis-000�e Compound Fibrous
Heterogeneous
02-03-Te�ure Sheetrock/Joint White 100% Non-fibrous(other) None Detected
zziioosis-000s Compound Non-Fibrous
Homogeneous
02-03-Joint Sheetrock/Joint Beige 100% Non-fibrous(other) None Detected
Compound Compound Non-Fibrous
221100615-OOO8A
Homogeneous
Initial report from 02/24/2011 16:12:24 I
Analyst(s)
DeCavallas Michael(29) Erin Orthun,Laboratory Manager
Molly Walker(23) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL
bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be
used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a
problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Printed:2/24/2011 4:1224 PM 2
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112
Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom
Attn: Quentin Danziger
Customer ID: INES78
Q Consulting, IIIC. Customer PO:
PO Box 997 Received: 02/24/11 8:45 AM
Vail, CO 81658 EMSL Order: 221100615
Fax: Phone: (970)390-0087
EMSL Proj: Town of Vail
Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance % Fibrous % Non-Fibrous % Type
02-03-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected
zziioosis-000se Compound Fibrous
Heterogeneous
02-04-Te�ure Sheetrock/Joint White 100% Non-fibrous(other) None Detected
zziioosis-000s Compound Non-Fibrous
Homogeneous
02-04-Joint Sheetrock/Joint Beige 100% Non-fibrous(other) None Detected
Compound Compound Non-Fibrous
221100615-0009A
Homogeneous
02-04-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected
zziioosis-000se Compound Fibrous
Heterogeneous
02-05-Texture Sheetrock/Joint White 100% Non-fibrous(other) None Detected
zziioosis-ooio Compound Non-Fibrous
Homogeneous
02-05-Joint Sheetrock/Joint White/Beige 100% Non-fibrous(other) None Detected
Compound Compound Non-Fibrous
221100615-OOlOA
Homogeneous
Initial report from 02/24/2011 16:12:24 I
Analyst(s)
DeCavallas Michael(29) Erin Orthun,Laboratory Manager
Molly Walker(23) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL
bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be
used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a
problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM 3
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112
Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom
Attn: Quentin Danziger
Customer ID: INES78
Q Consulting, IIIC. Customer PO:
PO Box 997 Received: 02/24/11 8:45 AM
Vail, CO 81658 EMSL Order: 221100615
Fax: Phone: (970)390-0087
EMSL Proj: Town of Vail
Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance % Fibrous % Non-Fibrous % Type
02-05-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected
zziioosis-ooioe Compound Fibrous
Heterogeneous
03-01 Cove Base Yellow 100% Non-fibrous(other) None Detected
zziioosis-ooii Mastic-Upper Non-Fibrous
Homogeneous
03-02 Cove Base Yellow 100% Non-fibrous(other) None Detected
zziioosis-ooiz Mastic-Upper Non-Fibrous
Homogeneous
03-03 Cove Base Tan 100% Non-fibrous(other) None Detected
221100615-0013 Mastic-Lower Non-Fibrous
Homogeneous
04-01-Floor Tile VRC Upper Floor Tan 100% Non-fibrous(other) None Detected
221100615-0014 Tile Non-Fibrous
Homogeneous
04-01-Mastic VRC Upper Floor Clear 100% Non-fibrous(other) None Detected
221100615-0014A Tile Non-Fibrous
Homogeneous
04-02-Floor Tile VRC Upper Floor Tan 100% Non-fibrous(other) None Detected
221100615-0015 Tile Non-Fibrous
Homogeneous
Initial report from 02/24/2011 16:12:24 �
Analyst(s)
DeCavallas Michael(29) Erin Orthun,Laboratory Manager
Molly Walker(23) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL
bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be
used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a
problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Printed:2/24/2011 4:1224 PM 4
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112
Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom
Attn: Quentin Danziger
Customer ID: INES78
Q Consulting, IIIC. Customer PO:
PO Box 997 Received: 02/24/11 8:45 AM
Vail, CO 81658 EMSL Order: 221100615
Fax: Phone: (970)390-0087
EMSL Proj: Town of Vail
Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance % Fibrous % Non-Fibrous % Type
04-02-Mastic VRC Upper Floor Clear 100% Non-fibrous(other) None Detected
221100615-0015A Tile Non-Fibrous
Homogeneous
04-03-Floor Tile VRC Upper Floor Tan 100% Non-fibrous(other) None Detected
zziioosis-oois Tile Non-Fibrous
Homogeneous
04-03-Mastic VRC Upper Floor Clear 100% Non-fibrous(other) None Detected
221100615-0016A Tile Non-Fibrous
Homogeneous
05-01 VRC Lower Floor Tan 100% Non-fibrous(other) None Detected
zziioosis-oon Tile Non-Fibrous
Heterogeneous
05-02 VRC Lower Floor Tan 100% Non-fibrous(other) None Detected
zziioosis-oois Tile Non-Fibrous
Heterogeneous
05-03 VRC Lower Floor Tan 100% Non-fibrous(other) None Detected
zziioosis-oois Tile Non-Fibrous
Heterogeneous
06-01 Subway Floor Tile Tan 100% Non-fibrous(other) None Detected
zziioosis-oozo Non-Fibrous
Homogeneous
Initial report from 02/24/2011 16:12:24 �
Analyst(s)
DeCavallas Michael(29) Erin Orthun,Laboratory Manager
Molly Walker(23) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL
bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be
used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a
problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM 5
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112
Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom
Attn: Quentin Danziger
Customer ID: INES78
Q Consulting, IIIC. Customer PO:
PO Box 997 Received: 02/24/11 8:45 AM
Vail, CO 81658 EMSL Order: 221100615
Fax: Phone: (970)390-0087
EMSL Proj: Town of Vail
Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance % Fibrous % Non-Fibrous % Type
06-02-Floor Tile Subway Floor Tile Tan 100% Non-fibrous(other) None Detected
z2tioosis-oozi Non-Fibrous
Homogeneous
06-02-Mastic Subway Floor Tile Yellow 100% Non-fibrous(other) None Detected
221100615-0021A Non-Fibrous
Homogeneous
06-03-Floor Tile Subway Floor Tile Tan 100% Non-fibrous(other) None Detected
z2iioosis-oozz Non-Fibrous
Homogeneous
06-03-Mastic Subway Floor Tile Yellow 100% Non-fibrous(other) None Detected
221100615-0022A Non-Fibrous
Homogeneous
07-01-Mastic VRC Lower Carpet Yellow/Clear 100% Non-fibrous(other) None Detected
221100615-0023 Mastic Non-Fibrous
Heterogeneous
07-01-Leveler VRC Lower Carpet White 100% Non-fibrous(other) None Detected
221100615-0023A Mastic Non-Fibrous
Homogeneous
07-02-Mastic VRC Lower Carpet Yellow/Clear 100% Non-fibrous(other) None Detected
221100615-0024 Mastic Non-Fibrous
Heterogeneous
Initial report from 02/24/2011 16:12:24 �
Analyst(s)
DeCavallas Michael(29) Erin Orthun,Laboratory Manager
Molly Walker(23) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL
bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be
used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a
problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM 6
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112
Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom
Attn: Quentin Danziger
Customer ID: INES78
Q Consulting, IIIC. Customer PO:
PO Box 997 Received: 02/24/11 8:45 AM
Vail, CO 81658 EMSL Order: 221100615
Fax: Phone: (970)390-0087
EMSL Proj: Town of Vail
Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance % Fibrous % Non-Fibrous % Type
07-02-Leveler VRC Lower Carpet White 100% Non-fibrous(other) None Detected
221100615-0024A Mastic Non-Fibrous
Homogeneous
07-03-Mastic VRC Lower Carpet Yellow/Clear 100% Non-fibrous(other) None Detected
221100615-0025 Mastic Non-Fibrous
Heterogeneous
07-03-Leveler VRC Lower Carpet White 100% Non-fibrous(other) None Detected
221100615-0025A Mastic Non-Fibrous
Homogeneous
08-01 VRC Upper Carpet Tan 100% Non-fibrous(other) None Detected
zziioosis-oozs Mastic Non-Fibrous
Heterogeneous
08-02 VRC Upper Carpet Tan 100% Non-fibrous(other) None Detected
zziioosis-ooz� Mastic Non-Fibrous
Heterogeneous
08-03 VRC Upper Carpet Tan 100% Non-fibrous(other) None Detected
zziioosis-oozs Mastic Non-Fibrous
Heterogeneous
09-01 Window Caulking Gray/Clear 100% Non-fibrous(other) None Detected
zziioosis-oozs Non-Fibrous
Heterogeneous
Initial report from 02/24/2011 16:12:24 �
Analyst(s)
DeCavallas Michael(29) Erin Orthun,Laboratory Manager
Molly Walker(23) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL
bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be
used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a
problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM �
EMSL Analytical, Inc.
7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112
Phone: ("s03)740-570Q Fax: (303)741-140Q Email: denverlab@emsLcom
Attn: Quentin Danziger
Customer ID: INES78
Q Consulting, IIIC. Customer PO:
PO Box 997 Received: 02/24/11 8:45 AM
Vail, CO 81658 EMSL Order: 221100615
Fax: Phone: (970)390-0087
EMSL Proj: Town of Vail
Project: Lionshead Subway Building-TOV-Town Of Vail Analysis Date: 2/24/2011
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Non-Asbestos Asbestos
Sample Description Appearance % Fibrous % Non-Fibrous % Type
09-02 W indow Caulking Gray/Clear 100% Non-fibrous(other) None Detected
221100615-0030 Non-Fibrous
Heterogeneous
09-03 W indow Caulking Gray/Clear 100% Non-fibrous(other) None Detected
221100615-0031 Non-Fibrous
Heterogeneous
10-01 W hite Caulking Gray/W hite 100% Non-fibrous(other) None Detected
221100615-0032 Non-Fibrous
Heterogeneous
10-02 W hite Caulking Gray/W hite 100% Non-fibrous(other) None Detected
221100615-0033 Non-Fibrous
Heterogeneous
10-03 W hite Caulking Gray/W hite 100% Non-fibrous(other) None Detected
221100615-0034 Non-Fibrous
Heterogeneous
Initial report from 02/24/2011 16:12:24
Analyst(s)
DeCavallas Michael(29) Erin Orthun,Laboratory Manager
Molly Walker(23) or other approved signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL
bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be
used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal govemment. Non-friable organically bound materials present a
problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted.
Samples analyzed by EMSL Analytical,Inc.Centennial,CO NVLAP Lab Code 200828-0
Test Report PLM-7.23.0 Printed:2/24/2011 4:12:24 PM THIS IS THE LAST PAGE OF THE REPORT. $