HomeMy WebLinkAboutF08-0080TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970 - 479 -2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
SPRINKLER PERMIT Permit #: F08 -0080
V o lyDG - o(Y of
Job Address: 635 LIONSHEAD PL VAIL Status ...: ISSUED
Location.....: LIONS SQUARE LODGE NORTH Applied..: 10/02/2008
Parcel No...: 210107204001 Issued . .. 12/03/2008
Project No Expires. .:
OWNER POWELL, WILLIAM R. & PAULA W 10/02/2008
1200 PALMETTO DR
HUBBARD
OH 44425
APPLICANT ALL STATE FIRE PROTECTION,
6045 E 76TH #12
COMMERCE CITY
CO 80022
License: 370 -S
CONTRACTOR ALL STATE FIRE PROTECTION,
6045 E 76TH #12
COMMERCE CITY
CO 80022
License: 370 -S
Desciption: NEW FIRE SPRINKLER SYSTEM
Valuation: $253,337.00
I 10/02/2008 Phone: 303 - 288 -3901
I 10/02/2008 Phone: 303 - 288 -3901
s* s#**#####ss#+s+s***#*###**##s##+s+s s * * * + * * * #s * * * + * #s * +s ++ + * * * * * #s# FEE SUMMARY ***###* t###s+*s+*+# s#####s### s #s *s * + * #s #s * + * * * #ss * * * # # * #ss ++
Mechanical --- >
$0.00 Restuarant Plan Review —> $0.00
Total Calculated Fees —>
$11,116.82
Plan Check - ->
$350.00 DRB Fee---------- - - - - -> $0.00
Additional Fees — ----- >
$150.00
Investigation ->
$0.00 TOTAL FEES----- - - - - -> $11,116.82
Total Permit Fee--- - - - - ->
$11,266.82
Will Call --->
$0.00
Payments - - - -- -- - - - - ->
$11,266.82
BALANCE DUE--- - - - - ->
$0.00
########## 4 ## 4 ####s#################s#s#######################s######*########## t###+####*##s####
s################ s# ## # # # # # # # # # # # # # ## # # # # # # # # # ##
Item: 05100 BUILDING DEPARTMENT
Item: 05600 FIRE
DEPARTMENT
11/24/2008
mcgee Action: AP
42 West Meadow Drive
Vail, Colorado 81657
970 - 479 -2250
November 24, 2008
Plan Review - Lion Square North Fire Sprinkler Plan F08 -0080
for
(Plan
We have reviewed the plans and specifications for the fire sprinkler and standpip(
Lion Square North. Findings and comments are as follows:
1.
Vail Fire
Department is not the source for
the flow data. Please correct ti
2.
The plan
legend shows six different symbols
but only two identifying head z
3.
The fire
hose valve detail is not accurate.
FHV's shall be installed at 60
the floor with valves at a 45 degree angle to the floor.
4. FDC's shall be installed at 36 inches above grade to the center of the cone
notes 2 and 30
5. Equipment submittals were not specified as to size, model, and other featui
Resubmission is required. (General Note 1)
6. NICET does not typically certify "engineers" but rather "engineering techn:
FPE
of Record is understood to be Shanner Life Safety.
7. The National Fire Protection Association does not provide "engineering star
(General Notes 2, 5 and 14)
8. A spare head cabinet should be provided. NFPA requires more than a single t
(General
Note 15)
9. Telluride standards are inapplicable in this instance. (General Note 18)
10. Install low point drains on standpipes (FP -4)
11. Floor control valve appears to have been left off plans at Node B10 (FP -4)
12. Install isolation valves for heads in elevator pits (typ) (FP -6)
13. Notes referencing NFPA 13 -D are inapplicable. Per Town of Vail adopted cod(
standards, fire sprinkler heads are required in "owner's closets ". (FP -6)
14. Fire check valves may not be located in the elevator equipment room per AN!
(FP -6)
15.Plan indicates "crawl space ". Crawl space is not reflected on section. Such
area(s) may be required to be sprinklered and detected if accessible for storage.
Resubmit materials book with specifications as to number and size and other appli(
details.
Resubmit standpipe riser with corrections.
Identify source of flow data.
End of Review.
Michael McGee, FSSI 006
Deputy Chief
Vail Fire & Emergency Services
970 479 -2135
05/06/2009 mvaughan Action: AP revision approval
07/17/2009 mvaughan Action: AP revision for parking garage approved.
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
** w**** w*+++ ws*** w* w* s*+******+*+*+ s+*+****++ s* s**+**** s+*+++++***** w****+*+ s******** swss+s****** w*++++*********+ srs + + + * * * * * * * * * * +s + + + + * * * * * *s + ++
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252
FROM 8:00 AM - 5 PM.
SIGNATURE OF/OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: R090000905 Amount: $150.00 07/24/200912:46 PM
Payment Method: Check Init: LC
Notation: #24021 /ALL
STATE FIRE PROTECTION
----------------------------------------------------------------------- - - - - --
Permit No: F08 -0080 Type: SPRINKLER PERMIT
Parcel No: 2101 - 072 - 0400 -1
Site Address: 635 LIONSHEAD PL VAIL
Location: LIONS SQUARE LODGE NORTH
Total Fees: $11,266.82
This Payment: $150.00 Total ALL Pmts: $11,266.82
Balance: $0.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
PF 00100003112300 PLAN CHECK FEES 150.00
TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES.
SPRINKLER PERMIT
Job Address: 635 LIONSHEAD PL VAIL
Location.....: LIONS SQUARE LODGE NORTH
Parcel No...: 210107204001
Project No
OWNER POWELL, WILLIAM R. & PAULA W 10/02/2008
1200 PALMETTO DR
HUBBARD
OH 44425
APPLICANT ALL STATE FIRE PROTECTION,
6045 E 76TH #12
COMMERCE CITY
CO 80022
License: 370 -S
CONTRACTOR ALL STATE FIRE PROTECTION,
6045 E 76TH #12
COMMERCE CITY
CO 80022
License: 370 -S
I Desciption: NEW FIRE SPRINKLER SYSTEM
Valuation: $253,337.00
Permit #: F08 -0080
"-? ?S 6G - pzs� Z
Status ...: ISSUED
Applied..: 10/02/2008
Issued . .. 12/03/2008
Expires. .:
I 10/02/2008 Phone: 303 - 288 -3901
I 10/02/2008 Phone: 303 - 288 -3901
FEE SUMMARY ***++s+s+++*ssss*+**s+*s*+**+ *s * + + + + + +s + ++ * +ssssss +ss * + + * +s+
Mechanical - ->
$0.00 Restuarant Plan Review - -> $0.00
Total Calculated Fees --- >
$11,116.82
Plan Check - ->
$350.00 DRB Fee------------ ------- > $0.00
Additional Fees — --------- >
$0.00
Investigation ->
$0.00 TOTAL FEES — ----------- > $11, 116.82
Total Permit Fee ---------- >
$11,116.82
Will Call - - - ->
$0.00
Payments ------- — ---------- >
$11, 116.82
BALANCE DUE --------- >
$0.00
++**+***++s*+*+***+********+***+s++ss+**s*******************+++++++s+s+s*++**+********++**
ss*+s*+s ss+***s*s+*+**+* +s + * * + +s * + *s + + * +ss *ssss *sss * *ss
Item: 05100 BUILDING DEPARTMENT
Item: 05600 FIRE
DEPARTMENT
11/24/2008
mcgee Action: AP
42 West Meadow Drive
Vail, Colorado 81657
970- 479 -2250
November 24, 2008
Plan Review - Lion Square North Fire Sprinkler Plan F08 -0080
We have reviewed the plans and specifications for the fire sprinkler and standpipe
Lion Square North. Findings and comments are as follows:
1. Vail Fire Department is not the source for the flow data. Please correct ti
2. The plan legend shows six different symbols but only two identifying head i
3. The fire hose valve detail is not accurate. FHV's shall be installed at 60
the floor with valves at a 45 degree angle to the floor.
4. FDC's shall be installed at 36 inches above grade to the center of the cone
notes 2 and 30
5. Equipment submittals were not specified as to size, model, and other featui
Resubmission is required. (General Note 1)
6. NICET does not typically certify "engineers" but rather "engineering techn_
of Record is understood to be Shanner Life Safety.
7. The National Fire Protection Association does not provide "engineering star
(General Notes 2, 5 and 14)
8. A spare head cabinet should be provided. NFPA requires more than a single 1
Note 15)
9. Telluride standards are inapplicable in this instance. (General Note 18)
10. Install low point drains on standpipes (FP -4)
11. Floor control valve appears to have been left off plans at Node B10 (FP -4)
12. Install isolation valves for heads in elevator pits (typ) (FP -6)
13. Notes referencing NFPA 13 -D are inapplicable. Per Town of Vail adopted cod(
standards, fire sprinkler heads are required in "owner's closets ". (FP -6)
14. Fire check valves may not be located in the elevator equipment room per AN!
(FP -6)
15.Plan indicates "crawl space ". Crawl space is not reflected on section. Such
area(s) may be required to be sprinklered and detected if accessible for storage.
Resubmit materials book with specifications as to number and size and other applie
details.
Resubmit standpipe riser with corrections.
Identify source of flow data.
End of Review.
Michael McGee, FSSI 006
Deputy Chief
Vail Fire & Emergency Services
970 479 -2135
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY -TWO HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252
FROM 8:00 AM - 5 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
0 •
TOWN OF VAIL, COLORADOCopy Reprinted on 12 -03 -2008 at 10:23:47 12/03/2008
Statement
Statement Number: R080002277 Amount: $11,116.8212/01 /200810:15 AM
Payment Method: Check Init: DDG
Notation: All State Fire
Protection, Inc. 3000004
-----------------------------------------------------------------------------
Permit No: F08 -0080 Type: SPRINKLER PERMIT
Parcel No: 2101- 072 - 0400 -1
Site Address: 635 LIONSHEAD PL VAIL
Location: LIONS SQUARE LODGE NORTH
Total Fees: $11,116.82
This Payment: $11,116.82 Total ALL Pmts: $11,116.82
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
BP 00100003111100 SPRINKLER PERMIT FEES 10,766.82
PF 00100003112300 PLAN CHECK FEES 350.00
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNE
Project M !�
Building Permit #: (Cl
Sprinkler Permit #: — S0
JOE 970- 479 -2135 (Inspections)
TOA'N
TOWN OF VAIL FIRE SPRINKLER PERMIT APPLICATION
Fire Sprinkler shop drawings are required at time of permit submittal and
75 S. Frontage Rd. must include the following. Permit application will not be accepted
Vail, Colorado 81657 without this information:
A Colorado Registered Engineer's stamp or N.I.C.E.T. Level III (min) stamp.
• Equipment cut sheets of materials.
• Hydraulic calculations.
A State of Colorado Plan Registration form.
• Plans must be submitted by a Registered Fire Protection Contractor.
CONTRACTOR INFORMATION
Fire Sprinkler Contractor: Town of Vail Reg. No.: Contact and Phone #'s:
�, �'S -3 2
E -Mail Address:
Contractor Signature* _
i
COMPLETE VALUATIONS FOR ALARM PERMIT (Labor 8 1 4erials) j
L Fire Sprinkler: $ y5 3
TOWN OF VAIL-
n..s.,s C�..Ie r•nnniv dcccccnia nfrcc at 970.328 -8640 or visit www.eaole- countv.com for Parcei # M
- ---
Parcel # t q00
Job Name:
Job Address
Legal Description
Lot:
Block: LI Filing:
Subdivision:
Owners Name: Address: Phone..
Engineer:
Address:
Phone:
Detailed Location of work: (i.e., floor, unit #, bldg. #)
Detailed description of work:
0S La
Work Class: New () Addition ( ) Remodel ( ) Repair( ) Retro -fit ( ) Other v ) P6�_� sfi
Type of Bldg.: Single- family ( ) Two - family ( ) Multi- family ( ) Commercial ) Rest urant ( ) Other( )
No. of Existing Dwelling Units in this building:
No. of Accommodation Units in this building:
Does a Fire Alarm Exist: Yes( ) No ( ) Does a Fire Sprinkler System Exist: Yes( ) No LL
* ****** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *FOR OFFICE USE ONLY***** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
\ \Vaii\data \cdev \FORMS \PERMITS \SPRKPERM.DOC 07/24/2002