Loading...
HomeMy WebLinkAboutF08-0080TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F08 -0080 V o lyDG - o(Y of Job Address: 635 LIONSHEAD PL VAIL Status ...: ISSUED Location.....: LIONS SQUARE LODGE NORTH Applied..: 10/02/2008 Parcel No...: 210107204001 Issued . .. 12/03/2008 Project No Expires. .: OWNER POWELL, WILLIAM R. & PAULA W 10/02/2008 1200 PALMETTO DR HUBBARD OH 44425 APPLICANT ALL STATE FIRE PROTECTION, 6045 E 76TH #12 COMMERCE CITY CO 80022 License: 370 -S CONTRACTOR ALL STATE FIRE PROTECTION, 6045 E 76TH #12 COMMERCE CITY CO 80022 License: 370 -S Desciption: NEW FIRE SPRINKLER SYSTEM Valuation: $253,337.00 I 10/02/2008 Phone: 303 - 288 -3901 I 10/02/2008 Phone: 303 - 288 -3901 s* s#**#####ss#+s+s***#*###**##s##+s+s s * * * + * * * #s * * * + * #s * +s ++ + * * * * * #s# FEE SUMMARY ***###* t###s+*s+*+# s#####s### s #s *s * + * #s #s * + * * * #ss * * * # # * #ss ++ Mechanical --- > $0.00 Restuarant Plan Review —> $0.00 Total Calculated Fees —> $11,116.82 Plan Check - -> $350.00 DRB Fee---------- - - - - -> $0.00 Additional Fees — ----- > $150.00 Investigation -> $0.00 TOTAL FEES----- - - - - -> $11,116.82 Total Permit Fee--- - - - - -> $11,266.82 Will Call ---> $0.00 Payments - - - -- -- - - - - -> $11,266.82 BALANCE DUE--- - - - - -> $0.00 ########## 4 ## 4 ####s#################s#s#######################s######*########## t###+####*##s#### s################ s# ## # # # # # # # # # # # # # ## # # # # # # # # # ## Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 11/24/2008 mcgee Action: AP 42 West Meadow Drive Vail, Colorado 81657 970 - 479 -2250 November 24, 2008 Plan Review - Lion Square North Fire Sprinkler Plan F08 -0080 for (Plan We have reviewed the plans and specifications for the fire sprinkler and standpip( Lion Square North. Findings and comments are as follows: 1. Vail Fire Department is not the source for the flow data. Please correct ti 2. The plan legend shows six different symbols but only two identifying head z 3. The fire hose valve detail is not accurate. FHV's shall be installed at 60 the floor with valves at a 45 degree angle to the floor. 4. FDC's shall be installed at 36 inches above grade to the center of the cone notes 2 and 30 5. Equipment submittals were not specified as to size, model, and other featui Resubmission is required. (General Note 1) 6. NICET does not typically certify "engineers" but rather "engineering techn: FPE of Record is understood to be Shanner Life Safety. 7. The National Fire Protection Association does not provide "engineering star (General Notes 2, 5 and 14) 8. A spare head cabinet should be provided. NFPA requires more than a single t (General Note 15) 9. Telluride standards are inapplicable in this instance. (General Note 18) 10. Install low point drains on standpipes (FP -4) 11. Floor control valve appears to have been left off plans at Node B10 (FP -4) 12. Install isolation valves for heads in elevator pits (typ) (FP -6) 13. Notes referencing NFPA 13 -D are inapplicable. Per Town of Vail adopted cod( standards, fire sprinkler heads are required in "owner's closets ". (FP -6) 14. Fire check valves may not be located in the elevator equipment room per AN! (FP -6) 15.Plan indicates "crawl space ". Crawl space is not reflected on section. Such area(s) may be required to be sprinklered and detected if accessible for storage. Resubmit materials book with specifications as to number and size and other appli( details. Resubmit standpipe riser with corrections. Identify source of flow data. End of Review. Michael McGee, FSSI 006 Deputy Chief Vail Fire & Emergency Services 970 479 -2135 05/06/2009 mvaughan Action: AP revision approval 07/17/2009 mvaughan Action: AP revision for parking garage approved. CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ** w**** w*+++ ws*** w* w* s*+******+*+*+ s+*+****++ s* s**+**** s+*+++++***** w****+*+ s******** swss+s****** w*++++*********+ srs + + + * * * * * * * * * * +s + + + + * * * * * *s + ++ DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SIGNATURE OF/OWNER OR CONTRACTOR FOR HIMSELF AND OWNER ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R090000905 Amount: $150.00 07/24/200912:46 PM Payment Method: Check Init: LC Notation: #24021 /ALL STATE FIRE PROTECTION ----------------------------------------------------------------------- - - - - -- Permit No: F08 -0080 Type: SPRINKLER PERMIT Parcel No: 2101 - 072 - 0400 -1 Site Address: 635 LIONSHEAD PL VAIL Location: LIONS SQUARE LODGE NORTH Total Fees: $11,266.82 This Payment: $150.00 Total ALL Pmts: $11,266.82 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts PF 00100003112300 PLAN CHECK FEES 150.00 TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES. SPRINKLER PERMIT Job Address: 635 LIONSHEAD PL VAIL Location.....: LIONS SQUARE LODGE NORTH Parcel No...: 210107204001 Project No OWNER POWELL, WILLIAM R. & PAULA W 10/02/2008 1200 PALMETTO DR HUBBARD OH 44425 APPLICANT ALL STATE FIRE PROTECTION, 6045 E 76TH #12 COMMERCE CITY CO 80022 License: 370 -S CONTRACTOR ALL STATE FIRE PROTECTION, 6045 E 76TH #12 COMMERCE CITY CO 80022 License: 370 -S I Desciption: NEW FIRE SPRINKLER SYSTEM Valuation: $253,337.00 Permit #: F08 -0080 "-? ?S 6G - pzs� Z Status ...: ISSUED Applied..: 10/02/2008 Issued . .. 12/03/2008 Expires. .: I 10/02/2008 Phone: 303 - 288 -3901 I 10/02/2008 Phone: 303 - 288 -3901 FEE SUMMARY ***++s+s+++*ssss*+**s+*s*+**+ *s * + + + + + +s + ++ * +ssssss +ss * + + * +s+ Mechanical - -> $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > $11,116.82 Plan Check - -> $350.00 DRB Fee------------ ------- > $0.00 Additional Fees — --------- > $0.00 Investigation -> $0.00 TOTAL FEES — ----------- > $11, 116.82 Total Permit Fee ---------- > $11,116.82 Will Call - - - -> $0.00 Payments ------- — ---------- > $11, 116.82 BALANCE DUE --------- > $0.00 ++**+***++s*+*+***+********+***+s++ss+**s*******************+++++++s+s+s*++**+********++** ss*+s*+s ss+***s*s+*+**+* +s + * * + +s * + *s + + * +ss *ssss *sss * *ss Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 11/24/2008 mcgee Action: AP 42 West Meadow Drive Vail, Colorado 81657 970- 479 -2250 November 24, 2008 Plan Review - Lion Square North Fire Sprinkler Plan F08 -0080 We have reviewed the plans and specifications for the fire sprinkler and standpipe Lion Square North. Findings and comments are as follows: 1. Vail Fire Department is not the source for the flow data. Please correct ti 2. The plan legend shows six different symbols but only two identifying head i 3. The fire hose valve detail is not accurate. FHV's shall be installed at 60 the floor with valves at a 45 degree angle to the floor. 4. FDC's shall be installed at 36 inches above grade to the center of the cone notes 2 and 30 5. Equipment submittals were not specified as to size, model, and other featui Resubmission is required. (General Note 1) 6. NICET does not typically certify "engineers" but rather "engineering techn_ of Record is understood to be Shanner Life Safety. 7. The National Fire Protection Association does not provide "engineering star (General Notes 2, 5 and 14) 8. A spare head cabinet should be provided. NFPA requires more than a single 1 Note 15) 9. Telluride standards are inapplicable in this instance. (General Note 18) 10. Install low point drains on standpipes (FP -4) 11. Floor control valve appears to have been left off plans at Node B10 (FP -4) 12. Install isolation valves for heads in elevator pits (typ) (FP -6) 13. Notes referencing NFPA 13 -D are inapplicable. Per Town of Vail adopted cod( standards, fire sprinkler heads are required in "owner's closets ". (FP -6) 14. Fire check valves may not be located in the elevator equipment room per AN! (FP -6) 15.Plan indicates "crawl space ". Crawl space is not reflected on section. Such area(s) may be required to be sprinklered and detected if accessible for storage. Resubmit materials book with specifications as to number and size and other applie details. Resubmit standpipe riser with corrections. Identify source of flow data. End of Review. Michael McGee, FSSI 006 Deputy Chief Vail Fire & Emergency Services 970 479 -2135 CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY -TWO HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER 0 • TOWN OF VAIL, COLORADOCopy Reprinted on 12 -03 -2008 at 10:23:47 12/03/2008 Statement Statement Number: R080002277 Amount: $11,116.8212/01 /200810:15 AM Payment Method: Check Init: DDG Notation: All State Fire Protection, Inc. 3000004 ----------------------------------------------------------------------------- Permit No: F08 -0080 Type: SPRINKLER PERMIT Parcel No: 2101- 072 - 0400 -1 Site Address: 635 LIONSHEAD PL VAIL Location: LIONS SQUARE LODGE NORTH Total Fees: $11,116.82 This Payment: $11,116.82 Total ALL Pmts: $11,116.82 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 SPRINKLER PERMIT FEES 10,766.82 PF 00100003112300 PLAN CHECK FEES 350.00 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNE Project M !� Building Permit #: (Cl Sprinkler Permit #: — S0 JOE 970- 479 -2135 (Inspections) TOA'N TOWN OF VAIL FIRE SPRINKLER PERMIT APPLICATION Fire Sprinkler shop drawings are required at time of permit submittal and 75 S. Frontage Rd. must include the following. Permit application will not be accepted Vail, Colorado 81657 without this information: A Colorado Registered Engineer's stamp or N.I.C.E.T. Level III (min) stamp. • Equipment cut sheets of materials. • Hydraulic calculations. A State of Colorado Plan Registration form. • Plans must be submitted by a Registered Fire Protection Contractor. CONTRACTOR INFORMATION Fire Sprinkler Contractor: Town of Vail Reg. No.: Contact and Phone #'s: �, �'S -3 2 E -Mail Address: Contractor Signature* _ i COMPLETE VALUATIONS FOR ALARM PERMIT (Labor 8 1 4erials) j L Fire Sprinkler: $ y5 3 TOWN OF VAIL- n..s.,s C�..Ie r•nnniv dcccccnia nfrcc at 970.328 -8640 or visit www.eaole- countv.com for Parcei # M - --- Parcel # t q00 Job Name: Job Address Legal Description Lot: Block: LI Filing: Subdivision: Owners Name: Address: Phone.. Engineer: Address: Phone: Detailed Location of work: (i.e., floor, unit #, bldg. #) Detailed description of work: 0S La Work Class: New () Addition ( ) Remodel ( ) Repair( ) Retro -fit ( ) Other v ) P6�_� sfi Type of Bldg.: Single- family ( ) Two - family ( ) Multi- family ( ) Commercial ) Rest urant ( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: Does a Fire Alarm Exist: Yes( ) No ( ) Does a Fire Sprinkler System Exist: Yes( ) No LL * ****** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *FOR OFFICE USE ONLY***** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** \ \Vaii\data \cdev \FORMS \PERMITS \SPRKPERM.DOC 07/24/2002